Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED BLD2022-1672+Mechanical_Plan+12.9.2022_11.20.36_AM+3261186
VAR'S EDMONDS IVAR'S SEAFOOD BAR 9910 EDMONDS WAY, EDMONDS, WA 98020 RTU REPLACEMENT PROJECT DATA ems. � -� -���}_ ' •: -� V I'IMOM _ � a a - 1._ J � f _ A � w �s-. �_ - -'�'; �- Ti—�� � s ! •RYr -a.... __sue� N A SATELLITE MAP M 0.0 NOT TO SCALE Y �CII3•geP9in1 Crtarning g[anon COVIP490nVe- Tesitnq aI WdIBl— aEhS Seto Safn wvk Sveolas Las Edmonds KwKk KI.. CBI Wash \ WWk Earye Bach we Klds 3lenlisVy ® Q 1M : Starbu&s ®vv +tea ,. / Edm _ � Ono AiIlfRnhc awallen _— _ • t0a ^ � — 92 r-------� h4yP ® Tne uPSSlweO © Kry6ar,s , Iva" S[,■� k'a'Id Pany MallboxGplds Quellt ootl Bar 9M�>_c�Eamon¢s fiuslne55Centaa ® m y Consignments , , .r,. ..- S-Salon Pnd Spay 0anell OrugsO Chopsl,rk5 _ _ _ y Bartell ():ugs PharmacyQ BePy Ham,hOaQ S gfd—ds C.—fil B n ' ' _ f �1j� Henys Bmgel Farmers tnsuaanee Aaron Zwedach 9 S Tne Tnkc Sjcp-4>1a Presehwf 231 It PISW 231at PISW y Cara and � a a a s � N B VICINITY MAP M -0 NOT TO SCALE . The following documentation shall be available on ' site for the building inspector: '[:]COE APPROVED ARCHITECTURAL PLAN SET ' : ❑ COE APPROVED STRUCTURAL PLAN SET ; ® COE REVIEWED CALCULATION PACKET ❑ ENERGY CREDIT WORKSHEET '. ❑ SITE PLAN ; ❑ CIVIL PLAN i ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 ; 1. JURISDICTION: CITY OF EDMONDS 2. PARCEL NUMBER: 27033600113500 3. TENANT NAME: IVAR'S 4. PRESENT USE: GROCERY STORE 5. LEGAL DESCRIPTION: SEC 36 TWP 27 RGE 03 RT-14) BEG NW COR OF NW1/4 SW1/4 NW1/4 NE1/4 TH S 30FT TH S89*50 44E 180FT TPB TH CONT S89*50 44E 150.71 FT TO E LN OF SD N89*50 44W 151.24FT TH N00*1944W 170FT TPB LESS S/HY SCOPE OF WORK 1. REPLACE EXISTING ROOFTOP HEAT PUMP FOR MAINTENENCE UPGRADE. DRAWING INDEX M0.0 TITLE SHEET MO.1 SITE PLAN M1.0 ROOF PLAN, WSEC COMPLIANCE, ELEVATIONS AND EQUIPMENT SCHEDULE M2.0 CUT SHEETS 1 M2.1 CUT SHEETS 2 PROJECT NOTES City Of Edmonds Building Department Aroved Date -------------------------------------------------------- pp ------------------------------------------------------------ E 03/21/202 Building Official YI�Ci C/� Permit Number BLD2022-1672 1. ALL WORK SHALL COMPLY WITH THE 2018 WASHINGTON STATE ENERGY CODE AND THE 2018 INTERNATIONAL MECHANICAL CODE INCLUDING ALL AMENDMENTS MADE BY THE STATE OF WASHINGTON AND THE CITY OF EDMONDS. I W� COMERCIAL CD 0 r, F' COMERCIAL L.— SITE PLAN SCALE: 1/32" = V-0" COMERCIAL ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE H W 104 I 83'-31162'-511 RTU-1 APPROVED PLANS MUST BE ON JOB SITE COMERCIAL 999-1111 \ \ I \ \ \ \ COMERCIAL i I Q1 m U) = N Co D O 000 U) 0) z w0 z� w \ / Z 00 � Q CO O CO Z 0-) V STAMP: RECEIVED 12/9/2022 CITY OF EDMONDS DEVELOPMENT a�R'v CES DEPARTiviEi�T REVISIONS 0 DATE DESCRIPTION y 0 E 0 W ^ CD v ` \ V CD 0 3: M LL O w 0 Cn E vi U (n w C 0 W 0 -0 d rnw O cn W Q U /•/D m z y C N O a � p (D E N W N c 00 �¢ LOU W U p z N W N of m co= z (B U co U U W z N W 20 i o O w U w a m > CO N a, o (n k 0 � LU Y LL Q 1 + SHEET NUMBER: MO.0 Title Sheet I:revA : &TA I I I I � I � I I m I ;u I I > I I I I I I I � I ° I m I ; I I I o I I � I � I � I I D I I I I I I I I I I I I I I I I I I I � I Cn I I I � I I � I I I I o I m I I c� I o I D I I I I � I - ' I - � I � I � I I � I I I I � I I I I i I I I I I � I I I I I / I I / I / I / I / I I I I o / m I � / � I I D I Ivar's Edmonds RTU Replacement PROJECT NAME 12.08.2022 DATE CREATED Archp1/16" = 1' SHEET SIZE SCALE ALT DRAFTER JOB NUMBER +1 (253) 872-7392 KEY MECHANICAL PHONE PROJECT SITE ADDRESS: Ivar's Seafood Bar Edmonds 9910 Edmonds Way, Edmonds, WA 98020 D D m m i O Z O z cn Gl ni <� n M� j TI /V m T N n < { 0 �C) C7 p m n, m T' m O < {zz M 2 0 I I I I I I I I I I I I I I I I I I I I I I I I I I I I Key Mechanical 19430 68TH AVENUE SOUTH SUITE B KENT, WASHINGTON 98032 L� GENERAL NOTES 1. UNIT TO BE PLACED IN SAME LOCATION ON ROOF AS THE UNIT IT IS REPLACING. 2. OTHER ROOFTOP EQUIPMENT SHOWN FOR REFERANCE ONLY. RTU-1 W, ROOF PLAN SCALE: 1/8" = V-0" W ~ 12/8/22, 3:49 PM https://waenergycodes.com/print project_summary_form.php?k=aWQ9MTUwNDQmZnZpPTE3JnJIc2VOPTE=&debug=1 V 'D//�� MFrffWNICAL COMPLIANC _ 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all R I Administered by: ©2022 NEEA, All rights reserved co O O Project Title Ivar's Edmonds RTU Replacements - 2018 WSEC For Building Department Use: I Date: Dec 08, 2022 Project Address 9910 Edmonds Way, 00 Project &Applicant Edmonds, WA98020 Applicant Name Wayne Cornell Information Z Applicant Phone 253-872-7392 Applicant Email wcomell@keymechanical.com Z O For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Dining, Fast Food Building Cond. FloorArea 3,066 11 W (D General Project Types Building Addition New Building or Addition Alteration Single Zone Systems & Equipment Project Cond. Floor Area 3,066 Floors Above Grade 1 Alteration Mechanical Scope Compliance Method Compliance Method 1 -General Mechanical Scope— Mechanical Project Description REMOVE/REPLACE EXISTING ROOFTOP HEAT PUMP FOR MAINTENENCE PURPOSES. U) 00 Mechanical Compliance Project Type Mechanical Scope Economizer Exception(s) � Applied. DOAS Ventilation Provided? Higher Equipment Efficiency Option Applied? Equipment Efficiency Compliance Verification Scope and Method Single Zone Systems & Alteration Equipment Yes No NA COMPLIES O Additional Efficiency Credits Included (AEC) CO Z :I- C7 W Does building include occupancy classifications requiring DOAS? No Does project include DOAS equipment? No Based on project scope do TSPR requirements apply? No Do all systems comply with Appendix D standard reference design or qualify for an exception to N TSPR. Scope & Space Conditioning ALTERATION - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES Single Zone Air Systems Category, - Ileat pump, packaged (PTHP, SPVHP, room) Air Systems Summary Information System/Equip ID Quantity of Items Supply Airflow Control Ventilation Standard Ventilation CFM (Total if Multiple Items) Ventilation Air Source Paired with DOAS Ventilation energy recovery Energy Recovery Efficiency (%) RTU-1 I I Variable air volume I ASHRAE Standard 62.1 1 Other System Air Systems & Equipment - Cooling System/ Cooling System/Equip Cooling AEC Econo Exception Combined Efficiency Proposed CE Proposed Part PI, Efficiency Equip Type Specific Type Capacity Efficiency Multiplier (FL & Multiplier (AEC & Cooling Units Load LoadUnits Compliance ID per item (Btu/h) Multiplier PL) Econo) Efficiency Verification RTU-1 Heat pump, terminal (PTHP) Packaged terminal HP, replacement 63,000 1 0 1 EER COMPLIES Air Systems & Equipment - Heating System Heat Pump Heating Capacity Cah Coolingpaci AEC Proposed Heat HPH Proposed Low LTH Efficiency /Equip Heating System/Equip Type Specific Type (Btu/h) (BtCa Efficiency Pump Units OSA Units Compliance ID Multiplier Heating Efficiency Temp Efficiency Verification RTU-I Heat pump, terminal (PTHP), Packaged terminal HP, 54,000 63,000 1 80.6 COP COMPLIES heating replacement Air Systems & Equipment Details System/Equip Area(s) Served Location In Project Documents - Plan/Detail # ID https://waenergycodes.com/print—Project—summary form - ph p?k=a WQ9MTUwN DQmZnZpPTE3JnJIc2V0PTE=&debug=1 12/8/22, 3:49 PM https://waenergycodes.com/print_ project_summary_form.php?k=aWQ9MTUwNDQmZnZpPTE3JnJIc2VOPTE=&debug=1 1/2 RTU-1 STORE I ALL System/Equip ID for a single or multiple items?: Single item Economizer Compliance Method: Air -side economizer provided WSEC Equip Efficiency Reference Table - Cooling: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC Equip Efficiency Reference Table - Heating: Table C403.3.2(3) - Packaged Terminal and Vertical AC and HP WSEC COMPLIANCE NOT TO SCALE TOP OF WALL ROOF ELEVATIONS NOT TO SCALE ROOFTOP EQUIPMENT ID Make Model Control Type Static Pressure RPM H/P Voltage Phase MCA Weight (lbs) Height Base Size NEW RTU-1 CARRIER 48GCDM06A2A5 ELECTROMECHANICAL 0.6 2087.0 0.97 208 3 31 600.0 42" 7511x47" EXISTING RTU-1 CARRIER 48H DT006510 1075.0 0.5 208 3 40 685 3111 80"x44" ROOFTOP EQUIPMENT CONTINUED ID TYPE Economizer COOLING CAPACITY BTU/H R SEER HEATING CAPACITY BTU/H R CFM DB INPUT OUTPUT Thermal Eff NEW RTU-1 HEAT PUMP YES 63,000 16 67,000 54,000 80.6% 2000 79 EXISTING RTU-1 HEAT PUMP 581000 8.1 1201000 951400 79.5% 3800 EQUIPMENT SCHEDULE STAMP: RECEIVED 12/9/2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTiviENT REVISIONS 0 DATE DESCRIPTION 70 O 0 U) U) C� �C:) M N O 00 0 Q 0 Ev 0-0 w C O O E W z 0 U)LLJ U N L L Q Cfi mz C �ZO N a � p W E N w N I, o0 W U O Z N W ^ N Of m M= Z Of Cl) 2z N i O CD H U w ¢ m > d (n —J Y Q 1 + SHEET NUMBER: M 1 .0 NOT TO SCALE Rooftop Plan, WSEC, Elevations, Schedule Unit Report For 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Unit Parameters Dimensions (ft. in.) & Weight (lb.) *** Unit Model: 48GCDM06A2A5-OAOAO Unit Length: ------------------------------------------- ------------- 6' 2.375" Unit Size: 06 (5 Tons) Unit Width------------- 3' 10.625" Volts -Phase -Hertz: 208-3-60 Unit Height:..-.-... 3' 5.375" Heating Type: Gas *** Total Operating Weight: 600 lb Duct Cfg: Vertical Supply / Vertical Return Low Heat *** Weights and Dimensions are approximate. Weight does Two Stage Cooling Models not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Lines and Filters Gas Line Size:____ _______ 1/2 Condensate Drain Line Size: 3/4 Return Air Filter Type: Throwaway Return Air Filter Quantity:_ ___ __ 4 Return Air Filter Size: _ _ 16 x 16 x 2 Selection includes construction throwaway filter into the base fan curve. This filter is not MERV Rated. Unit Configuration Direct Drive - EcoBlue - Medium Static AI/Cu - AI/Cu Base controls set up for field installed air management devices Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantit 48GCDM06A2A5-OAOAO Rooftop Unit 1 Base Unit Direct Drive - EcoBlue - Medium Static Electromechanical control, No intake or exhaust option. Field Installed Accessories CRECOMZRO67AO1 Ultra LOW LEAK - Vertical EconoMi$er X with solid-state W7220 controller 1 Packaged Rooftop Builder 1.68 Page 3 of 10 Certified Drawing for 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM NOTES: 1. DIMENSIONS ARE IN INCHES, DIMENSIONS IN [ ] ARE IN MI LLIMETEAS. UNIT J N 2. CENTER OF GRAVITY 48GCr•04 33 3/8 18 5/8 [847] [472] 3. � DIRECTION OF AIR FLOW 48GCrr05 33 3/8 [847] (377] 14 7/8 i � 48GC••06 4 ,� 4. �} ALL VIEW DRAWN USING 3AD ANGLE [11 0513/8] [472]185/8 WMA ' ECONOMIZER HOOD ' (OPTIONAL) [•� 25-5/8 — [6521 RETURN AIR 1 Cl 121 1I T� li'_SE�� C A 4 2X 23-3/4 [101] K [6031 2% 25 2X d-5/8 [635] TOP I, 187 ELECTRICAL DISCONNECT LOCATION OPTIONAL CONDENSER A, B,G FACTORY INSTALLED CONTROL BOX ACCESS PANEL COIL DISCONNECT OPTIONAL FACTORY INSTALLED D �. CONVENIENCE OUTLET 19-1 /2 11-1 /4 14941 [2877 11681 - O O HANDLE 39314 I5] 46-5/8 111861 30-1/8 141 21214] [766] 74 LEFT [1889)91 FRONT M 10-7/8 RE [277] AIR is- /2 11-3/4 451I [748] SUPPLY 26-5/8 AIR [675] SUPPLY T� AIA 6-1/4 3-1/4 I81] 11581 12-1 /8 [307] 18-318 [4661 CONNECTION SIZES A 1 3/8" [35I DIA FIELD POWER SUPPLY HOLE B 2" (501 DIA POWER SUPPLY KNOCKOUT C 1 3/4" 1511 DIA GAUGE ACCESS PLUG D 7/8" [221 DIA FIELD CONTROL WIRING HOLE E 3/4"-14 NPT CONDENSATE DRAIN F 1/2"-14 NPT GAS CONNECTION G 2 112 " [641 DIA POWER SUPPLY KNOCKOUT d •e i 4• ••4 1 E STD. 10-7/8 CONDENSATE [275] 1 1251 • T FILTER 7��,,i 17-3/8 INDOOR BLOWER ACCESSPANEL., [302] 1 21 -1 /4 OUTSIDE 1 ° (539) AIR O 5-3/4 6-3/8 7 5-314 1146) [)fill 11771 26-1/8 11461 (682]It 31 [786] BAROMETRIC RELIEF RETURN SUPPLY AIR FLOW ATA RIGHT :EDES 48GC 04-06 SINGLE PACKAGE ELECTRICAL 46TC003099 REV 3/18 COOLING WITH GAS HEAT 3 Packaged Rooftop Builder 1.68 Page 4 of 10 Certified Drawing for 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM i FILTER ACCESS PANEL COMP. CONDENSER I TOOL -LESS( ACCESS PANEL COIL INDOOR COIL ACCESS PANEL 0 (INSIDE THE BASEASE RAIL & SKIRT) 4-1 / O (INSIDE THE I1047] 1 BA4 SE RAILS( 2-1/4 [ 571 INSIDE BASERAIL DIMENSIONS 2X I-3/4 BOTTOM dal46 0 ij 2X 1-3/8 t 21 1 3-114 1361 [251 DEATIL C [821 2X 3/4 TYP 4 PLCS Ita1 3-7/8 [99] CONTROL BOX ACCESS PANEL INDOOR BLOWER ACCESS PANEL DETAIL C BACK LEFT I az 1 z-318 [62] TYP CURB 59-3/8 7-1/8 WIDTH [15091 11811 FRONT ITC CLASSIFICATION SHEET DATE SUPERCEDES 48GC 04-06 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSR 3 OF 3 09/07/18 08/03/18 COOLING WITH GAS HEAT 48TC003099 B Packaged Rooftop Builder 1.68 Page 6 of 10 Certified Drawing for 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM �f1F31'0®®m®m®m�m�� II�III�III�IIIIIi■(III®Illll�lllll�lll['m' llll�lllllall��® 4- STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTINS AND ACCESSORIES REFER TO THE PRODUCT DATA CATALOG. CORNER A Y CORNER D X O TOP CORNER B CORNER C i BACK WITH ECONOMIZER R12 112 BACK [318I \ WITHOUT ECONOMIZER ECONOMIZER HOOD 1 OPTIONAL DOOR[__'� (OPTIONAL) SWING -- LEFT I• RIGHT U 74-5/8 FRONT [1896] NOTES: 1. FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. Z CLEARANCE SERVICE WITH: SERVICE WITH: OPERATING O SURFACE CONDUCTIVE BARRIER NONCONDLICTIVE BARRIER CLEARANCE FRONT 48 [1219mm] 36 [914mm] 18 [457mm? O J LEFT 48 11219mm] 42 11067mm] 18 [457mm] BACK 48 11219mm] 42 [1067mm] 18 (457mm) BACK W/HOOD 36 [914mm) 36 [914mm] 18 [457mm] RIGHT 36 [914mm] 36 [914mm] 18 [457mm] TOP 72 [1829mm] 72 [1829mm] 72 [1829mm] ITC CLASSIFICATION SHEET DATE SUPERCEDES 48GC 04-06 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSR 2 OF 3 09/E"1B 08/03/18 COOLING WITH GAS HEAT 48TC003099 B Packaged Rooftop Builder 1.68 Page 5 of 10 Date: Weight: 45lbs (US) 20.41kg (Metric) Part Number: ECD-SRT12CB-D2DH MicroMetl g RTU: Submitted to: Approved by: Notes: Economizer - Economizer - Genesis Ultra Low Leak Economizer, Vertical Orientation, Honeywell Jade W7220 Single/Multiple Speed Electromechanical Controller, Adjustable Dry Bulb Sensor, Honeywell Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. For Differential Return Air Sensor Please Order 9901-2022-DIFF JC2 FEATURES: • External gear driven dampers with roll formed blades. Hinged Filter access door, • Designed for vertical applications only. sold separately. • Factory assembled rain hood, with aluminum water entrainment filters. - • Filter access door supplied with RTU. • Hinged filter access door is ordered separately. • MMC P/# for Chassis 1- ECD-SRTICA-HDOOR Direct coupled • MMC P/# for Chassis 2 - ECD-SRT2CA-HDOOR actuator mount • Rain hood is sloped for water run off. • All harnesses and plugs needed are supplied. 9 • Economizer is class IA & AMCA rated. • Relief blades are AMCA rated. • Uses niter rack with unit. � • Motorized relief available add -M to end of art number ' P � 0 16.936 0/A HOOD HOOD • Ex: ECD-SRTI2CB-D2DH-M Q 1 I DEPTH • Economizer with smoke detector available, add -S to end of part number Packing tape. To be removed • Ex: ECD-SRTI2CB-D2DH-S prior to installation. -Control Types -D2DH W7220 controller, actuator w/feedback, adjustable drybulb controls -D2EH W7220 controller, actuator w/feedback, enthalpy controls uutsiae air sensor location 16.163 32.341 )NOMIZER ECONOMIZER O.D. DEPTH 25.687 mca R I0/A, R/A, RELIEF I.D. CERTIrIED ® ® RRTIR6f �/j}�• AIR 4D. �r�y9 il r O A tEnKiltifl I D 16.766 ® OO ECONOMIZER 8.255 O.D. ° RELIEF I.D.Will ail I. Will W This Document Is The Property Of MicroMetl Corporation And Is Delivered Upon The Express Condition That The Contents Will Not Be Disclosed Or Used Without MicroMetl's Written Consent. Master Revision 0001 A MicroMetl Reserves The Right To Discontinue, Or Change At Any Time, Specifications & Designs Without Any Notice Incurring Obligations. Page Revision 0001 A ndianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 • O w V ~ U) = N C) `O00 ^^ VJ C, w z Z (DW z 2 00 c CO IZT '�' ' STAMP: RECEIVED 12/9/2022 CITY OF EDMONDS DEVELOPMENT REVISIONS I0 DATE DESCRIPTION 0 O E 0 W L W CD M 0 Cn O O > w I_ v) 0 E fn_ co ~ U UJ C: O W 0 L 0 2 —0 VJ W W Z 0 w UCN F-� U LL Z M W Z oO a � Ea N W O LOU � co U W U z N w 0 N Of m M= z to i ° W 00 o ff- r ° n I—� W � 2 U.) Z N U LU M a) of No Uw LM Jo m ° �Y > LL r Q Q I + SHEET NUMBER: M2.0__, Equipment Cut Sheets Performance Summary For 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Date: Weight: 45lbs (US) 20.41kg (Metric) Part Number: ECD-SRT12CB-D2DH RTU: gMicroMetl Submitted to: Approved by: Notes: Economizer - Economizer - Genesis Ultra Low Leak Economizer, Vertical Orientation, Honeywell Jade W7220 Single/Multiple Speed Electromechanical Controller, Adjustable Dry Bulb Sensor, Honeywell Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. For Differential Return Air Sensor Please Order 9901-2022-DIFF JC2 Compliant Economizer: 1. Title 24: Economizers meet California Energy Commission Title 24-2013 / 2016 prescriptive section 140.4 (damper leakage etc.), and mandatory section 120.2.i for Fault Detection and Diagnostic controls (JADE HJW10). 5 Year Warranty for parts and components only. 2. ASHRAE 90.1: Economizers meet ASHRAE 90.1-2013 / 2016 damper leakage requirements, and meet 2016 Fault Detection and Diagnosis requirements. 3. IECC: Economizers meet IECC 2012, IECC 2015, and IECC 2018 for outside air, return air, and relief damper (when provided) leakage requirements, and IECC 2015 and IECC 2018 for Fault Detection and Diagnostic requirements. 4. AMCA: Outside air and return air (volume) dampers are AMCA Class 1 A rated at 1" w.g. Refer to MicroMetl NS2 catalog sheet on web site for details. Relief air dampers (when provided) are also AMCA rated. Refer to GR1 series catalog sheet on web site for details. Features: • For single or 2 speed indoor fan units with Central Terminal Board (CTB) and Compressor Staging Board. Other control options available. • Gear driven design for trouble -free operation, eliminating slippage and binding associated with standard linkage. PlF•K • Includes assembled rainhood with aluminum water entrainment filters in the outside air section. NIR OGG • Rainhood is sloped for water run-off. AIR ronron.nnor • Built-in barometric relief damper provided. Power exhaust options available. • All harnesses and plugs needed are provided. • Uses standard factory filter access door shipped with HVAC unit. • If factor hinged access door option is installed on unit, an additional kit is required to seal hinged doorproperly. MicroMetl corporation y g p q g certifies that the models - OEM part no. CRPECONVO03A00 or MicroMetl part number 0640-0100-HDANGL GR1 and NS2 shown herein are licensed to bear the AMCA Seal. Notes: The ratings shown are based on tests and 1. Control systems include Honeywell W7220 JADE controller, mixed (supply) air temperature sensor, OA sensor in description, and spring -return procedures performed in communicatingactuator some include differential return sensor as noted). accordance with AMCA t( ) Publication 511 and 2. JADE W7220 controller is field mounted in unit's control box. comply with requirements of the AMCA Certified 3. Mixed (supply) air sensor is field installed in indoor blower fan section. Ratings Programs. 4. Differential return sensor MicroMetl Part No. 9901-2022-DIFF JC2 is field installed in return duct. The AMCA certified ( ) Ratings Seal applies 5. ASHRAE, IECC, and Title 24 require the economizer controller be capable of reporting faults to a fault management application accessible by to Air Leakage and Air Performance ratings. day-to-day operating or service personnel, or annunciated locally on zone thermostats or in some codes other devices are acceptable. Refer to applicable code requirements and to MicroMetl instructions for suggestions. 6. For older single speed models without the Central Terminal Board the "-D2" part number is replaced by "-DJ". (See separate submittal). This Document Is The Property Of MicroMetl Corporation And Is Delivered Upon The Express Condition That The Contents Will Not Be Disclosed Or Used Without MicroMetl's Written Consent. Master Revision 0001 A Page Revision 0001 A MicroMetl Reserves The Right To Discontinue, Or Change At Any Time, Specifications & Designs Without Any Notice Incurring Obligations. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Performance Summary For 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. U N 1) FanCurve Airflow(CFM-thousands) RPM=2087 BHP=0.97 MaxirnwnRPM=2836 MaxlmumBHP=5.00 SC-SystemCuve RP-RatedPoint Performance Summary For 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Part Number:48GCDM06A2A5-OAOAO ARI SEER: 16.10 Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.6 in Unit Height: 41.4 in Operating Weight Base Unit Weight: _ _600 lb Total Operating Weight: 600 lb Unit Unit Voltage -Phase -Hertz: __ 208-3-60 Air Discharge: Vertical Fan Drive Type: Vane Axial Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: __ 67.0 F Entering Air Enthalpy:__ 31.44 BTU/Ib Evaporator Leaving Air DB: ____ ___ ___ ____ _____ 57.6 F Evaporator Leaving Air WB: 57.1 F Evaporator Leaving Air Enthalpy: 24.44 BTU/Ib Gross Cooling Capacity: __ 63.00 MBH Gross Sensible Capacity: _ 48.32 MBH Compressor Power Input: 4.11 kW Coil Bypass Factor: _ _ 0.047 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 95.0 F Gas Heating Input Capacity: 50.0 / 67.0 MBH Gas Heating Output Capacity: 40.0 / 54.0 MBH Temperature Rise: 25.0 F Thermal Efficiency (°/o): 81.0 Supply Fan External Static Pressure: 0.60 in wg Options / Accessories Static Pressure Economizer: 0.12 in wg Total Application Static (ESP + Unit Opts/Acc.): 0.72 in wg Fan RPM: 2087 Fan Power: 0.97 BHP NOTE: _ Selected IFM RPM Range: 1387 - 2390 Selection includes construction throwaway filter into the base fan curve. This filter is not MERV Rated. Electrical Data Voltage Range: 187 - 253 Compressor #1 RLA: 16.2 Compressor #1 LRA: 110 Indoor Fan Motor Type: ---__ MED Indoor Fan Motor FLA: 8.6 Combustion Fan Motor FLA (ea): 0.48 Packaged Rooftop Builder 1.68 Page 7 of 10 Unit Feature Sheet for 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Carrier WerMuster - 48 V C Winn, •r�m•-eer�'a;r HIGH EFFICIENT PACKAGED ROOFTOP GAS HEATINGIELECTRIC COOLING UNITS 16 SEER 3, 4, 5 TONS WEATHERMASTEV SERIES 48GC units are high efficient single packaged gas heating, electric codinq units that are pre -wired and charged wOh Puron IR-410j refrigerant The uriis are factory tested in both hearing and coaling modes. Units are rated in accordance with AHRI Standards 21W240 and have two stages o1 cooing capacity control. Approved and cerlilied by: rw w- •tor•• �MwYr+ 1: raq- tla•�rir,r M/Yi 19dN1R p 4 .r..uon.a STANDARD FEATURES INCLUDE: • Pamn ;11•4'Q41 HFC reingeranl • Meals and a coeds ASHRAE SC 1 enenq, efficiency levais ` Scrol cony eswrs with Internal I no 5,cak and orwAoad prolacllan • Two Stage coding capaclilr cort'ol ` SE E R's to 16.D and AFUE s to S1 t4 ` TXV ralrlgeranl mitring, system ` EYclusva non•cwrnosira caaposllo condansade pan In acoordance Wth ASHRAE Standard 62, s%xSrig design skier or oanlar drain • standa'd coetinp Wwallon up to 125'F 146'C) and down In 35'F I121C) • down Ic 2S' F f-4• Ct wlh winler start kd Pre•palnled ederio' panels and pdmar•ceated Yricnor oancls lesied to 500 hours sail spray oroteclion • Fully nsulolad cabinet • NEWDreciDrye-Eccaluc'-Technologylndoorfansystem uses Vane AK at inn desgn and alocl•orvcalif cammuraled moto' • New unit ComnN Board with Inhintre quick fan spood adlustmem ` E■clus ve GC solid-state ccM-ol for on-eroard d aanosl cs Wth LED e'ro'ccdadeslgnatannam lccntrol 09c Induced (tan gas heat combustion design • Radandant gas valves who up to two stages or heatng Low pressure and high presKirc sailcn pralecicd MAINTENANCEFEATURES: • Accass panels Wlh easy grip handier. • Inntwahvc cast soal no -slip screws on anti aocass panels • Two•ineh drsoosabie awm air tilers and Too -loss hhw accass door • Now .inn owivoi bead W tacltale s n7o a safety clrcWt Iro.ibicsrioolinq and s rri Illed contra box arrangamerd INSTALLATION FEATURES: • ThruAne•Iw'hom powarenlrVcapablWo ` S-1 port gas and elacldc connections • Full par:moier base !all whn bulGln riggingadaplers and fork slots • Field eonoorable ril oaracal in horaorilim airlhow STANDARD WARRANTY: • • C-}war heal excnangar - i s-year stainless siaai coon • r.-yrr compresso, • 7-yea- sysIDmVu"' • yrar pays • Many oF't oral upgrades aso available OPTION S INCLUDE BUT ARE NOT LIMITED TO: r Inoellocnl Syste-nVu contras win larqe dlsoay and status LED's • RTU Open Muh4Proloco DDC Gonlrols • supply and Rollin At Smdca OMOCIorl. high Slade coolers • Lowwad oondcrrser col quads • Dlsbanneel swncn and canytnlcnce oudat oAo a • stainless soft heal excnongar option • corrowan fes,Klart cell pealing_. • MERU•f3 Return A Fihcrs • Patented Humidi4YlZer° adaptlye dahumicincallon system • Hinged access canals • Integrated economnar syslam Lan and Ultra Lan Leakversorrs • Pnast Mentor Probactlon + Condensala Dvernorm Protection For a complete Isl of oDlions and acmiseries rotor to the P'oducl Data Calalpp for this ink Power Supply MCA: _ ___ 31 Power Supply MOCP (Fuse or HACR). 45 Disconnect Size FLA: 30 Disconnect Size LRA: 126 Electrical Convenience Outlet: None Outdoor Fan [Qty / FLA (ea)]: 1 / 1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 92.4 89.5 85.6 125 Hz 83.6 79.5 84.7 250 Hz 77.7 72.0 80.5 500 Hz 74.1 66.3 76.0 1000 Hz 70.9 68.4 72.4 2000 Hz 68.3 59.7 68.0 4000 Hz 64.4 53.0 62.8 8000 Hz 60.3 47.2 59.3 A -Weighted 77.5 72.3 79.0 Advanced Acoustics 2 4 3 t Advanced Accoustics Parameters 1. Unit height above ground: _ 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground: _ _ ___ 5.7 ft 4. Height of obstruction: 0.0 ft 5. Horizontal distance from obstruction to receiver: 0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft STAMP: IW LU U) = N Cie) C) OCC) U) CY) wz Z) O z �n W V > Z Q Q 00 Ce) z UJ Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1 k 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 L D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw Packaged Rooftop Builder 1.68 Page 8 of 10 RECEIVED 12/9/2022 CITY OF EDMONDS DEVELOPMENT SERViCES DEPARTMENT REVISIONS 0 DATE DESCRIPTION 70 O E W W U) W 0 W U) W i O M 0 co G< O > E u_ WO 0 VJ W W Z Ju U Co CN Z M W z a 0O r oz N W p Lu co _i U W U O Z N w 0 N Of m M= z cOW i U �U O �H n l-� W F_ 2 u7 z N� U Co (L)a No Uw >_� _J i m ° �Y > Q Q i + SHEET NUMBER: M2. 1 Packaged Rooftop Builder 1.68 Page 9 of 10 Packaged Rooftop Builder 1.68 Page 10 of 10 Equipment Cut Sheets