Loading...
REVIEWED BLD2022-1672+Manufacturer_Specifications_and_Installation_Instructions+12.9.2022_9.37.01_AM+3260783a rrier SUBMITTAL Project Ivars Edmonds Date Thursday, August 18, 2022 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM 5T GasEle Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.68 Page 2 of 10 Unit Report For 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Unit Parameters Unit Model: ..................................... 48GCDM06A2A5-OAOAO Unit Size: ....................................................................... 06 (5 Tons) Volts -Phase -Hertz: ...................................................... 208-3-60 Heating Type: ............... Gas Duct Cfg:..................... Vertical Supply / Vertical Return Low Heat Two Stage Cooling Models Lines and Filters Gas Line Size: 112 Condensate Drain Line Size: 314 Return Air Filter Type: Throwaway Return Air Filter Quantity: 4 Return Air Filter Size: 16 x 16 x 2 Dimensions (ft. in.) & Weight (lb.) *** Unit Length: ...................................................... 6' 2.375„ Unit Width: ............................................................. 3,10.625" Unit Height: .............................................................. 3'5.375„ *** Total Operating Weight: ........................ 600 lb Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Selection includes construction throwaway filter into the base fan curve. This filter is not MERV Rated. Unit Configuration Direct Drive - EcoBlue - Medium Static AI/Cu - AI/Cu Base controls set up for field installed air management devices Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48GCDM06A2A5-OAOAO Rooftop Unit 1 Base Unit Direct Drive - EcoBlue - Medium Static Electromechanical control, No intake or exhaust option. Field Installed Accessories CRECOMZR067A01 Ultra LOW LEAK - Vertical EconoMi$er X with solid-state W7220 controller 1 Packaged Rooftop Builder 1.68 Page 3 of 10 Certified Drawing for 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM NOTES: 1. DIMENSIONS ARE IN INCHES, DIMENSIONS IN I I ARE IN MILL IMETEAS. 2. & CENTER OF GRAVITY 3. DIRECTION OF AIR FLOW 4. ALL VIEW DRAWN USING 3RD ANGLE q48GC--O6 K 3/8 18 5/847] [472]33-3/8 3/8 14 7/8[848] 47I [377I51] 1[4111 32-1/8 ' ECONOMIZER HOOD ' I817I (OPTIONAL) 6 25-5/8 I407I 652I RETURN AIR C 44-1/8 I1121] 0 -Y E ALA. CONDENSATE DRAIN OPENING %IN BAS EPAN 14-1/2 2 [369] 12-1/2 SEE THRU THE % [318] BASE CHART 1 411111111 10-7/8 RN 11771 AIR 29-i/2 17-3/4 I451I (748I 1* SUPPLY 26-5/8 AIR SUPPLY [675] AIA CONNECTION SIZES A 1 3/8" 1351 DIA FIELD POWER SUPPLY HOLE B 2" 1501 DIA POWER SUPPLY KNOCKOUT C 1 3/4" 1511 DIA GAUGE ACCESS PLUG D 7/8" 1221 DIA FIELD CONTROL WIRING HOLE E 3/4"-14 NPT CONDENSATE DRAIN F 1/2"-14 NPT GAS CONNECTION G 2 112 " 1641 DIA POWER SUPPLY KNOCK -OUT HOLESTHRU-THE-BASE CHART REQUIRED OR USE O08 i •'EIZE ■ 1 COTN1 ®' REO'D HOLE i0: ii PROVE FL 3-114 6-1/4 11-1/2 12931 10-1/8 (256] [81I 11581 2% 23-3/4 4 [101] 12 -1 /B FLUE [307I K [6031 HOOD 18-318 2% 25 [466] 2% 4-5/8 [635] TOP 1118] E STD. 10-7/8 ELECTRICAL CONDENSATE DRAIN [275] 1 [25] DISCONNECT LOCATION OPTIONAL FILTER CONDENSER A,B,G FACTORY INSTALLED CONTROL BOX ACCESS PANEL COIL DISCONNECT it-3/8 [65314 I441] SUPPLY AIR RETURN AIA OPTIONAL INDOOR BLOWER FACTORY J ACCESS PANEL INSTALLED D CONVENIENCE F 11 -7/8 OUTLET 19-1 /2 [302] 7,,21-1/4 OUTSIDE Jill��28714[494] [287] 39] AIR 11681 3-3/4 HANDLE 8-3/8 5-3/4 6-3/8 7 [161] I177I 5-3/4 [95] 46-5/8 [1186I 30 -1 /8 12141 HANDLE I146I 26-7/8 (146I [766] [682] LEFT 74-3/8 [1889] [786] 31 RETURN BAROMETRIC RELIEF SUPPLY AIR FLOW FRONT AIR RIGHT ITC CLASSIFICATION SHEET DATE SUPERCEDES 48GC 04-06 SINGLE PACKAGE ELECTRICAL REV U.S. ECCN:NSR 1 OF 3 09/07/18 08/03/18 COOLING WITH GAS HEAT 48TC003099 B Packaged Rooftop Builder 1.68 Page 4 of 10 Certified Drawing for 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM w- STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER 0PTI NS AND ACCESSORIES REFER TO THE PRODUCT DATA CATALOG. CORNER A Y CORNER D X 0 TOP n CORNER B CORNER C Z BACK WITH ECONOMIZER R12 112 BACK 13181 \ WITHOUT i NOMIZER HOOD ECONOMIZER ECONOMIZER 1 OPTIONAL DOOR (OPTIONAL) SWING LEFT NOTES: 1. FOR ALL MINIMUM CLEARANCES LOCAL CODES OR JURISDICTIONS MAY PREVAIL. RIGHT h--I FRONT d Packaged Rooftop Builder 1.68 Page 5 of 10 Certified Drawing for 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Caj� THIS DOCUMENT IS THE PROPERTY OF UTC CLIMATE, CONTRDLS �SUEMISSION OF THESE DAAWIXOS OR DOCUMENTS ie 8 flECUA1 TY AND IS DELIVERED UPON THE ENPflES1 CONDITION DOES NOT CONSTITUTE PAAi PEA FOANAXCE ON THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED ACCEPTANCE OF CONTRACT. 0 YYT�nMw� WITHOUT WRITTEN CONSENT. it-1/8 (INSIDE THE BASEASE RAIL 8 SKIRT) 41 -1 /4 O 047] (INSIDE THE BASE RAILS[ 0 (571 /4 0 0' INSIDE BASERAIL DIMENSIONS zz 1-7/B 2z 1-3/4 a BOTTOM 148 ] (461 0 zz 3-1/4 136] [25] DEATIL C [82] 2% 3/4 TYP 4 PLCS naI 3-7/8 1991 CONTROL BOX FILTER ACCESS PANEL COMP, Packaged Rooftop Builder 1.68 Page 6 of 10 Date: I Weight: 45lbs (US) 20.41 kg (Metric) I Part Number: ECD-SRT12CB-D2DH JAMicroMetil RTU: Submitted to: I Approved by: I Notes: Economizer - Economizer - Genesis Ultra Low Leak Economizer, Vertical Orientation, Honeywell Jade W7220 Single/Multiple Speed Electromechanical Controller, Adjustable Dry Bulb Sensor, Honeywell Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. For Differential Return Air Sensor Please Order 9901-2022-DIFF JC2 FEATURES: • External gear driven dampers with roll formed blades. • Designed for vertical applications only. • Factory assembled rain hood, with aluminum water entrainment filters. • Filter access door supplied with RTU. • Hinged filter access door is ordered separately. • MMC PI# for Chassis I - ECD-SRTICA-HDOOR • MMC PI# for Chassis 2 - ECD-SRT2CA-HD00R • Rain hood is sloped for water run off. • All harnesses and plugs needed are supplied. • Economizer is class 1A & AMCA rated. • Relief blades are AMCA rated. • Uses filter rack with unit. • Motorized relief available, add -M to end of part number • Ex: ECD-SRTI2CB-D2DH-M • Economizer with smoke detector available, add -S to end of part number • Ex: ECD-SRTl2CB-D2DH-S -Control Types -D2DH W7220 controller, actuator wlfeedback, adjustable drybulb wntrols D2EH W7220 controller, actuator wlfeedback, enthalpy controls 12.00 R/A I.D. Dirt acts, Hinged Filter ace sold separat Packing tape. To be rema prior to installation. `Outside air sensor location 16.436 O/A HOOD DEPTH 16.163 32.341 )NOMIZER ECONOMIZER O.D. DEPTH QMCA 2 OIA, RIA, RELIEF I.D. WORLDWIDE CERTIFIED RRTIRGf ® AIR WF_ OIA %tEttt(iIGEI.D. AIR 16.766 FIRFOR61R606ECONOMIZER 8.255 O.D. RELIEF I.D. This Document Is The Property Of MicroMetl Corporation And Is Delivered Upon The Express Condition That The Contents Will Not Be Disclosed Or Used Without MicroMetl's Written Consent. Master Revision 0001 A MicroMetl Reserves The Right To Discontinue, Or Change At Any Time, Specifications & Designs Without Any Notice Incurring Obligations. page Revision 0001 A Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC -- Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC -- Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Date: Weight: 45lbs (US) 20.41kg (Metric) Part Number: ECD-SRT12CB-D2DH MicroMetl RTU: Submitted to: Approved by: Notes: Economizer - Economizer - Genesis Ultra Low Leak Economizer, Vertical Orientation, Honeywell Jade W7220 Single/Multiple Speed Electromechanical Controller, Adjustable Dry Bulb Sensor, Honeywell Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware Included. For Differential Return Air Sensor Please Order 9901-2022-DIFF JC2 Compliant Economizer: 1. Title 24: Economizers meet California Energy Commission Title 24-2013 / 2016 prescriptive section 140.4 (damper leakage etc.), and mandatory section 120.2.i for Fault Detection and Diagnostic controls (JADE HJW10). 5 Year Warranty for parts and components only. 2. ASHRAE 90.1: Economizers meet ASHRAE 90.1-2013 / 2016 damper leakage requirements, and meet 2016 Fault Detection and Diagnosis requirements. 3. IECC: Economizers meet IECC 2012, IECC 2015, and IECC 2018 for outside air, return air, and relief damper (when provided) leakage requirements, and IECC 2015 and IECC 2018 for Fault Detection and Diagnostic requirements. 4. AMCA: Outside air and return air (volume) dampers are AMCA Class 1A rated at 1" w.g. Refer to MicroMetl NS2 catalog sheet on web site for details. Relief air dampers (when provided) are also AMCA rated. Refer to GR1 series catalog sheet on web site for details. Features: • For single or 2 speed indoor fan units with Central Terminal Board (CTB) and Compressor Staging Board. Other control options available. • Gear driven design for trouble -free operation, eliminating slippage and binding associated with standard linkage. • Includes assembled rainhood with aluminum water entrainment filters in the outside air section. IR IFr-fl- R6E • Rainhood is sloped for water run-off. AIR PfRtOPNRROE • Built-in barometric relief damper provided. Power exhaust options available. • All harnesses and plugs needed are provided. • Uses standard factory filter access door shipped with HVAC unit. • If factor hinged access door option is installed on unit, an additional kit is required to seal hinged door properly. MicroMetl Corporation y g p q g p p y' certifies that the models - OEM part no. CRPECONVO03A00 or MicroMetl part number 0640-0100-HDANGL GR1 and NS2 shown herein are licensed to bear the AMCA Seal. Notes: The ratings shown are based on tests and 1. Control systems include Honeywell W7220 JADE controller, mixed (supply) air temperature sensor, OA sensor in description, and spring -return procedures performed in actuator some include differential return sensor as noted). accordance with AMCA communicating ( ) Publication 511 and 2. JADE W7220 controller is field mounted in unit's control box. comply with requirements of the AMCA Certified 3. Mixed (supply) air sensor is field installed in indoor blower fan section. Ratings Programs. 4. Differential return sensor MicroMetl Part No. 9901-2022-DIFF JC2 is field installed itduct. The AMCA certified ( ) n reurn Ratings Seal applies 5. ASHRAE, IECC, and Title 24 require the economizer controller be capable of reporting faults to a fault management application accessible by to Air Leakage and Air Performance ratings. day-to-day operating or service personnel, or annunciated locally on zone thermostats or in some codes other devices are acceptable. Refer to applicable code requirements and to MicroMetl instructions for suggestions. 6. For older single speed models without the Central Terminal Board the "-D2" part number is replaced by "-DJ". (See separate submittal). This Document Is The Property Of MicroMetl Corporation And Is Delivered Upon The Express Condition That The Contents Will Not Be Disclosed Or Used Without MicroMetfs Written Consent. Master Revision 0001 A Page Revision 0001 A MicroMetl Reserves The Right To Discontinue, Or Change At Any Time, Specifications & Designs Without Any Notice Incurring Obligations. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC -- Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC -- Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Performance Summary For 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Part Number:48GCDM06A2A5-OAOAO ARISEER: ...................................................................................... ....................................................... 16.10 Base Unit Dimensions Unit Length: 74.4 in Unit Width: 46.6 in Unit Height: 41.4 in Operating Weight Base Unit Weight: 600 lb TotalOperating Weight: ................................................................................................................................................................................. 600 lb Unit Unit Voltage -Phase -Hertz: 208-3-60 Air Discharge: Vertical Fan Drive Type: Vane Axial Actual Airflow: 2000 CFM Site Altitude: 0 ft Cooling Performance Condenser Entering Air DB: 95.0 F Evaporator Entering Air DB: 80.0 F Evaporator Entering Air WB: 67.0 F Entering Air Enthalpy: 31.44 BTU/lb Evaporator Leaving Air DB: 57.6 F Evaporator Leaving Air WB: 57.1 F Evaporator Leaving Air Enthalpy: 24.44 BTU/lb Gross Cooling Capacity: 63.00 MBH Gross Sensible Capacity: 48.32 MBH Compressor Power Input: 4.11 kW Coil Bypass Factor: 0.047 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp: 70.0 F Leaving Air Temp: 95.0 F Gas Heating Input Capacity: 50.0 / 67.0 MBH Gas Heating Output Capacity: 40.0 / 54.0 MBH Temperature Rise: 25.0 F Thermal Efficiency (%): 81.0 Supply Fan External Static Pressure: Options / Accessories Static Pressure Economizer: Total Application Static (ESP + Unit Opts/Acc. FanRPM: -------------------------------------------------------------------------------- FanPower- ---------------------------------------------------------------------- NOTE---------------------------------------------------------------------------------------- 0.60 in wg 0.12 in wg 0.72 in wg -----------------------------------------------------------------------------------2087 ----- ............................................0.97 BHP --. Selected IFM RPM Range: 1387 - 2390 Selection includes construction throwaway filter into the base fan curve. This filter is not MERV Rated. Electrical Data Voltage Range: 187 - 253 Compressor #1 RLA: 16.2 Compressor #1 LRA: 110 Indoor Fan Motor Type: MED Indoor Fan Motor FLA: 8.6 Combustion Fan Motor FLA (ea): 0.48 Packaged Rooftop Builder 1.68 Page 7 of 10 Performance Summary For 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Power Supply MCA: 31 Power Supply MOCP (Fuse or HACR): 45 Disconnect Size FLA: 30 Disconnect Size LRA: 126 Electrical Convenience Outlet: None Outdoor Fan [Qty / FLA (ea)]: 1 / 1.5 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 92.4 89.5 85.6 125 Hz 83.6 79.5 84.7 250 Hz 77.7 72.0 80.5 500 Hz 74.1 66.3 76.0 1000 Hz 70.9 68.4 72.4 2000 Hz 68.3 59.7 68.0 4000 Hz 64.4 53.0 62.8 8000 Hz 60.3 47.2 59.3 A -Weighted 77.5 72.3 79.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: ------------------------------------------- 30.0 ft 2. Horizontal distance from unit to receiver: ---------- 50.0 ft 3. Receiver height above ground: 5.7 ft 4. Height of obstruction: ----------------------------------------------------------------- 0.0 ft 5. Horizontal distance from obstruction to receiver:.....0.0 ft 6. Horizontal distance from unit to obstruction: ............... 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 Ilk 2k 4k 8k Overall A 85.6 84.7 80.5 76.0 72.4 68.0 62.8 59.3 89.2 Lw B 59.4 68.6 71.9 72.8 72.4 69.2 63.8 58.2 78.5 LwA C 53.2 52.3 48.1 43.6 40.0 35.6 30.4 26.9 56.8 L D 27.0 36.2 39.5 40.4 40.0 36.8 31.4 25.8 46.1 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw Packaged Rooftop Builder 1.68 Page 8 of 10 Performance Summary For 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve OD 02 04 06 06 1.0 12 14 16 18 20 22 24 26 28 3D Airflow(CFM-thousands) RPM=2087 BHP=0.97 MaximumRPM=2836 MaxlmumBHP=5.00 SC-SystemCurveRP-RatedPoint Packaged Rooftop Builder 1.68 Page 9 of 10 Unit Feature Sheet for 5T GasEle Project: Ivars Edmonds 08/18/2022 Prepared By: 09:45AM Carrier . � � h . � da.■F- a �c■•tia�r HIGH EFFICIENT PACKAGED ROOFTOP GAS HEATINGJELECTRIC COOLING LIKITS 1E SEER 3,4, 5 TONS COMRUMT WEATHERMASTERe SERIES 48GC units are high efficient single packaged gas hewing, elertric soolina unilx Ihat are ure-wired and charged w,.h Puren IR,474j refrigerant. The urr's are factory tested in bath hewing and waling made%. Units are rated in aocordanoe ui h a4H111.I Standards 21 IN246 and have bna stages D1 coaling capacity control Approved and cerified by: CusL= r-:cr STANDARD FEATURES INCLUDE: ■ P.ircn:R•4'0AI HFC rcldgeronl F klecls and e■cceds ASHRAE CC i enorAy eifcloncy awals ■ S_rol cempTssars Kilh Inlernal I ne s-aak and aor lead p'olacllon + Tm Slogc ceding copocw CM931 ■ SE E R's m 1 G.0 and AFUE S Ia 61N ■ TMV rcldperonl welednp system • E■clur. ova non-aormr.W comp-0slla ceralensalo pan In anwrdanee nllh ASHRAE SlandaN 62, s oping deNgn sida or cenlar drain • Slanda-d codlnp eperollon up to 125'F 146':} and dew,, In 39'F 12•Cj - down to 2S F (.4' GI wih winker slorl k t • Pre�polnlad cderlo•panek and pdmar•cootad M rior nanols lerled to SW hours salt spray s'chetllon • Fully nsulaled caGlnat • NEW GmLi Dr vc- EcBSluo^ Tachndepp lndo-ar fan spslom us s Vane Arc al ran des gn and oloel'oNe2l4 aummttaied mate• • New Unil Co�n'el Surd wilh Inlulltrc qu" ran speed odlusimonl • E■clus ova GCsolid.slam ecnl'ei ror on-baord d agnosi cs tiNlh LED e'ro•rode ded9nacon ojn droanlrol Dga • Induead don pas heal oomhusllon dasgn ■ Rodwdanl ga64ol,, s wtln up Iowa slagas d healing • Low p-assjre and hlph prossLro sWilen praleded. MAINTENANCE FEA7URE3: ■ Access. panels ■Ilh aasy pr p handier. • Innevol„'e easy sorling. nNr.11p serows en untl amass ponds ■ Twa-inch dlsoasamikr racum air fllorsand Tan -less p11e•acrossdoor • New unh aanlnd toand roue ltie smo a sa"r1rcull Irauhks"xall•Lq and s cop Illed aanlra bat a'rangameM INSTALLATION FEATURES: • Thru-ine•baUom power entry eapoGllh • Enge ooM gas and elaclde ronnaellons • Full par meter tie -oil wtln hullo dppinp "niors and fork slats • Flold eon,'ertltllo ham ,'edleal Io hwaonha WrrBw STANDARD WARRANTY: • ' C-p'aar heal oxenangar - 1 G-yca• slolnless slael optlon ■ �-yea•romprossa• • 3-yea•8ysiomVuTM ■ ' -yea' p a'ts ■ Marryopioraluopradesascavallahk: OPTION S INCLUDE BUT ARE NDT LIMITED TO: Inacilowi SysL rnVu canines wih large dlsmiayard status LEM. • RTUOpen Mutl4ProtocaDDGGonlrak • Supply and Return AV 6moka l3claMors, hlph slotle molars • Lowered condenser col gua'ds ■ Dlseannocl swft i and ronvonlonen outial and ons • Slulntess Stec heal oxcnanpar opllon • Co'raLen rosklort cdl oaaling. • MERV.8 Relum A r Mors • Palonled Humldi-Mar9 adoptivo dahumidllaallon syslam • Hingad across canals • Inlapralod eacromtmr syslam Low "Ullra LvrLeak Tar. orrs • Pnasc MDNIcr Prohtrr-tlon • Cordensslo D,ne'nmr Prolaelhn For a m nplelo I sl of anil"s. and oemssarks rorar to the Pmducl Dale G2l2Iop Itx IhI& mt. Packaged Rooftop Builder 1.68 Page 10 of 10