Loading...
REVIEWED BLD2021-0171+Energy_Calculations+1.29.2021_12.26.39_PM+2021221bimme Heatina bmem bite: wasnlnaton State Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information JOHNSON RESIDENCE H2D ARCHITECTURE & DESIGN 71 19726 88TH AVE W, EDMONDS, WA 98026 HEIDI HELGESON: 206-542-3734 CORYPJOHNSON@GMAIL.COM HEIDI@H2DARCHITECTS.COM Heating System Type: O All Other Systems ® Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions". Design Temperature Instructions Design Temperature Difference (AT) I tlmands AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 2,920 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.0 23,360 Glazina and Doors U-Factor X Area = UA Instructions L u-o za 0.280 304 85.06 Skylights U-Factor X Area = UA Instructions 0.50 27 13.40 Insulation Attic U-Factor X Area = UA Instructions R-49 IV 0.026 1,622 42.17 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions R-38 Vented 0.027 681 18.40 Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21 Intermediate i 0.056 2,880 161.29 Floors U-Factor X Area UA Instructions Select R-Value No selection Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions 0.042 F 343 14.42 R-21 Interior Slab Below Grade isee Fioure v F-Factor X Length UA Instructions No Slab Below Grade in this project. � 0.303 --- Slab on Grade (see Fioure v F-Factor X Length UA Instructions �70 0.540 209 112.75 Perimeter Location of Ducts Instructions Duct Leakage Coefficient Conditioned Sparse 1.00 Sum of UA 447.49 Figure 1. Above Grade 46 Envelope Heat Load 20,584 Btu / Hour Sum of UA X AT Air Leakage Heat Load 11,605 Btu/Hour VolumeX 0.6XATX.018 Building Design Heat Load 32,190 Btu/Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 32,190 Btu/Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 40,237 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113)