Loading...
APPROVED PLN_ENG RESUB1 BLD2022-0387+SITE PLAN+5.9.2022_5.07.27_PM+2857781 2INSTALL SEDIMENT FENCING WHERE NEEDED TO PREVENT SEDIMENT FROM LEAVING THE PROPERTY. EX. FENCE i I i SEWER LINE I I i I I I 1 I i i 20C I F—; EX.5H' \I � \ \ \ I \ I 25.00' 2 5TOCKFIKLE LOCATION IF NEEDED. TO 5E COVERED WITHIN 24 HOUK5 - 5' MAX BLOCK WALL NEW DOWNSPOUTS PUT TO 5FLA5HBLOCK5 I i I i 126.00' I -------F---- ------ — -- —I I IPR P05ED I Ili I I A DITION I i i I I li I i I II i EXI5TIN6 i DECK EX15TiNG I. i k\E5IDENCEI� � 1 ; � I 1 D it li I i I i I 262 264 266 ALL D15TRUBED AREAS TO BE COMF05T AMENDED PER 2014 5WMMWW 5MP EXISTING DRIVEWAY PUD (METE ',I 1 \ I GASLI�.E --- rf I i 126.00' j 268 270 272 274 I / � I i � i 0 0 0 0 DATUM PT 275.00' FIRE HYDRANT 0 LEGAL DESCRIPTION: SIBON HEIGHTS 2 BLK 000 D-oo - LOT 10 PARCEL NUMBER: 00572400001000 LOT AREA: 12,600.00 SQ. FT. LOT COVERAGE: 2258.68 (22%) HEIGHT LIMIT: 25' HEIGHT CALCULATIONS: A. 268.45' B. 275.6o' C. 273.50' D. 266.25' /4 = AVERAGE GRADE = 270.95' ACTUAL HEIGHT PROPOSED: 288. 0' _j ACTUAL HEIGHT OF EXISTING: 289.16' MAX HEIGHT: 295.95' IMPERVIOUS SURFACE CALCULATON: EXISTING ROOF OUTLINE: 1859.17 SQ. FT. EXISTING DRIVEWAY: 748.8o SQ. FT. EXISTING DECK: 269.47 SQ. FT. EXISTING DECK REPLACE BY NEW ADDITION: 159.16 SQ. FT. EXISTING SHED: 216.00 SQ. FT. PROPOSED ROOF OUTLINE: 673.46 SQ. FT. TOTAL IMPERVIOUS = 3,926.50 SQ. FT. (NEW 673.46 SQ. FT.) APPROVED BY PLANNING May 26 2022 Through Lot ' Zone ;RS-8 Corner N Flag : N Setbacks: Required Actual Street 25' E = 31' Side 7.5� N = 8'-4" Side 7.5' S>7.5 Street ----------- 25' W>25' Height 25' <25' SETBACKS LISTED ARE TO PROPOSED STRUCTURES. OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED JdJ W44tp to 05/18/2022 VV Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. &I PLOT PLAN. SCALE: 1" = 20'-0" RESUB May 09 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT