BLD2022-0975_Mechanical_Plan_7.21.2022_1.12.09_PM_3004491SITE PLAN
E
Red Twig Cafe I
5th Avenue S
North
44
D
a
Y
t
O
n
S
T
Mechanical Schedule
HD-1
8' X 48" Hybrid (SIS Front and Ends) Box Hood with Short -Cycle Make -Up Air Including 3" Air
Gap on Back and Hanging Brackets See M-3
Type-1
Exhaust
20" x 20" x 2" Stainless Steel Filter
Hood
20" x 16" x 2" Stainless Steel Filter
Canopy Light With Tempered Globe
Grease Cup - New Style
(Pair) Stainless Steel Side CurtainsQuarter LIR -23" Top 23" High 0" Bottom
EF-1
28D DIRECT DRIVE EXHAUST FAN 115V, SINGLE PHASE,1/2 HP, UL762 LISTED
Type-1
Roof Curb for 20D-28D FLAT-17.5-17.5 See M— 4
Exhaust
10 AMP VARIABLE SPEED CONTROL for 36D
Fan
SF-1
SF7 Belt Drive Make -Up Air Fan See M— 5
Roof Curb for Makeup Air Fan - FLAT
HINGE KIT
Suppression
KIDDE 8' Pre -Piped Fire Suppression Sys. Incl.: Pipe, Conduit, Nozzles, Detection Brackets,
Micro Switch, Remote Pull Station, Gas Shut Off Valve, Control Heads, Tanks and Brackets (Doe
NOT Incl. Final Hook Up, Permits, Final Test)
Under
Seperate
Permit
City Of Edmonds
Building Department
Work �` TYPE 1 HOOD
Address 177 5TH AVE S
Owner'i -RED TWIG
Approved Date-----------------------
Building Official
--------------------- —
PermitNumberL B' D2D2 (�975_,i
Williams Mechanical
3903 Smith Ave.
Everett, WA 90201
Mechanical Scope
Install one 81 Type -I Hood,
Exhaust Fan, Supply fan,
Grease Duct, Stainless back
splash panels and gas piping
NOTE:
Fire Suppression and
Electrical Under Separate
ni.-.; }_
Red Twig Cafe
117 5th Ave S
Edmonds, WA 98020
M—n°2aE.+2022 s
7-12-22
Restrooms
Fire Suppression and
Control Panel Under
Separate Permits
16" Induction Burner
20" x 12" Make Up
Air duct down from
SF-1 on roof
Insulated per code
Entry
5th Avenue S
161 to
property line
13x13 Type-1
Welded 16 GA
Up to EF-1 on Roof
Firemaster Fire Wrap
1 30" Flat Top Griddle
33" Doublr Crepe
Griddle
8'x4' Type-1 Hood
Minimum 6"
HD-1 Overhang of Cooking
Surface
Kitchen Area Of Work
Williams Mechanical
3903 Smith Ave.
Everett, WA 90201
Building Outline
Red Twig Cafe
117 5th Ave S
RECEIVED
Jul 21 2022
M- lu �aa.M
-12
Edmonds, WA 980201
Roof Supports 6' on center
--a-----------------------------------�-
Q
1" Gas Pipe Down to
Suppression Shunt Valve by
others. ;
Gas Meter
Entry
5th Avenue S
1 16' to bronerty line
16x16 Intake Duct
*� Make Up Air Intake
I Minimum 10' Clearance
from any exhaust.
Williams Mechanical
3903 Smith Ave.
rinu rru
Red Twig Cafe
117 5th Ave S
Everett, WA 90201 l Edmonds , WA 98020
RECEIVED
M- 2�2, 2022
" F.a: ..
7-12-22
HEIM MAPM' T 172REASERCOURT PHONE:440-365-1399 TOLL FREE PH:800-715-1014 WWW.HOODMART.COM
rop rom SHOP ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX: 800-716-1214 SALES@HOODMART.COM
e
6*4
3"A
El
13x13 Grease Duct
4' Incandescent
Lig is T.Y.P.
20x12 Makeup Air
0 0
PLAN VIEW
SCALE: %'= V - 0"
DUCT OPENING ARE
RECOMMENDED
SIZES � ®L US
OPENINGS TO BE PUT ..uu /� �y LISTED
IN FIELD
MS�/NSF2 Safety
954iHed
Red TW1CJ Cafe RECEIVED
Williams Mechanical
M- 3.11212022
3903 Smith Ave. 117 5 th Ave S 7 _ 12�"_'2 2
Everett, WA 90201 Edmonds, WA 98020
Hood Details
HOOD MAX.O EXHAUST PLENUM Q SUPPLY PLENUM
HOOD
MODEL
LENGTH
COOKING
CONSTRUCTION
Hood Weight
TOTAL
RISERCS)
TOTAL
RISER(S)
NO.
TEMP.
EXH, CFM
SUP. CFM
DIA.
QTY.
CFM
S.P.
WIDTH
LENG.
QTY..
CFM
S.P.
96" NOM
700
16"
1
2000
O.5'
12"
18"
2
800
0.25"
1
MVA
96"OD
Deg.
2000
1600
STAINLESS/ALVMINIZEDS�S
MKD0ffJMAMT 172 REASER COURT PHONE: 440-365-1399 TOLL FREE PH: 800-715-1014 WWW.HOODMART.COM
roa PC=ANOP ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX: 800-716-1214 SALES@HOODMART.COM
EF-1
FAN MODEL
I A
I B
C
D
WT.
LBS.
28D
26y"
20�/"
16Y"
19" SO.
60 LBS.
FAN
Q1 EXHAUST FAN
IT
FAN VNITMODEL#
MODEL
TAG
CFM
S.P.
RPM
H.P.
O
VOLTS
FLA
Unit Weight
NO
28D
7,.,
50 lbs
1
28D
EF-1
2000
0.75"
1625
1/2
1
115
5.6
'il
MSI/NSF2
C UL US
LISTED
Safety Certified
MH29547
C�100�1/IART
�OIA! Of12 5T4r n,"" • enur
172 REASER COURT PHONE: 440-365-1399 TOLL FREE PH: 800-715-1014 WWW.HOODMART.COM
ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX: 800-716-1214 SALES@HOODMART.COM
F
B D
L
r�
L
NOT TO SCALE
FAN MODEL
A
B
C
D
1 WT
LBS.
SF7
24-
22-
22-
19%'
1 122 LB5.
FAN 2Q SUPPLY FAN
UNINOT FAN UNIT MODEL# MODEL TAG CFM S.P. RPM H.P. 0 VOLTS FLA Unit Weight
1 SF 1 SF7 5F-1 1600 0.25' 1028 3/4 1 115/230 - 122 lb S
�F
M81ANSF2
RECEIVED
C UL US
LISTED
Safety Certified
MH29547
Jul 21 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
RECEIVED
Jul 21 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
40" I Hinged Kit Access
20" Curb
Two Layers of
Firemaster Fire Wrap
See Submittale
201 Exhaust Cbambel�
3" Air Ga
S.S. Side Curtain
1" Stainless Panels
with Fire Rated Wool
Insulation
Concrete Block Wall
with framing and
sheetrock
EF-1
501bs F. 7—
Make-Up
Air Chamber
L100W Pre -Wired
Lights
Baffle Grease Filter
ss Steel Grease Cup
6'-6" - 6'-1"
A.F.F.
Equipment
provided/
installed by
others
SIPE VIEW
SCALE: %8"=1' - O"
.-k
Roof
Ceiling
Make Up Air Duct
Insulate per Code
i
MRINSF2
C UL US
LISTED
Safety Certified
MH29547
1��0171�/�I�T 172REASERCOURT PHONE:440-365-1399 TOLL FREE PH:800-715-1014 WWW.HOODMART.COM
ov tmo nw ELYRIA, OHIO 44035 FAX: 440-365-2100 TOLL FREE FAX: 800-716-1214 SALES@HOODMART.COM
I Intake with filter I
10' minimum clearance from
exhaust