Loading...
BLD2022-0975_MATERIAL INFO_7.21.2022_1.06.47_PM_3004465RECEIVED 11 MorganJul CITY OF OF 2022 CITY EDMONDS SERC Advanced Materials DEVELOPMENDEPARTMMENTENT CES Datasheet Code US: 714-236 © 2014 Thermal Ceramics is a business of Morgan Advanced Materials UL'11 W4., 01 VALIDATED LOA ✓ FIR EMASTERFASTWRAPXL IS LOW VOC EMITTING MATERIAL PER CA SECTION 01350 ✓ FIREMASTERFASTWRAPXL IS MOLD RESISTANT PER lllll_AST. C1338418 * Commonly referred to test method CA Section 01350 is CDPH Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers Version 1. 1, Feb 2010 Grease Duct Enclosure System Air Ventilation Duct Enclosure System Product Data & Installation Guide 1. Product Description Thermal Ceramics FireMaster° FastWrap XL is a flexible blanket composed of high temperature fibers classified for applications to 2192°F (1200°C) and fully encapsulated in a durable glass fiber reinforced foil facing for easy handling and installation. Thermal Ceramics FastWrap XL is UL and ULC Listed for 1 and 2 hour fire resistive enclosure protection, zero clearance for kitchen exhaust ducts, electrical circuit protection, and as a component in UL firestop designs for fire resistance rated floors, ceilings, and walls. The core fibers in FastWrap XL are manufactured using Thermal Ceramics patented Superwoole fiber which is an alkaline -earth silicate wool with low biopersistence and therefore increased safety for installers. FastWrap XL is under UL's Follow -Up Service Program to ensure the consistent quality essential to this life -safety application. BLD2022-0975 f/.vt& TER Product Features • Thin and Lightweight at 1-1/2" (38mm) thick, 6 pcf (96 kg/m3) density • Contours easily to complex duct designs • Grease duct installation UL and ULC Listed with butt joints at all seams on both layers • Fully foil encapsulated for fast and clean installation • Contains 2192°F (1200°C) rated fibers • Microbial Resistance validated by UL Environment • Good sound absorption • Compliant to IMC, NFPA 96, UMC, CMC, CNBC 2. Applications • 2 hour enclosure and firestop system for kitchen exhaus duct • Zero clearance to combustibles • 1, 2 and 3 hour enclosure and firestop system for hazardous exhaust ducts, pressurization ducts, clothes dryer exhaust ducts, trash and linen chutes, and other fire rated HVAC ducts • 1 hour electrical circuit integrity protection • Engineered and tested solutions for fire protection of structural steel and storage vessels per ASTM E119, ISO 834, and UL1709 3. Specifications - Division 23 07 00 (or 15080) CSI Spec and AutoCAD available online, www.arcat.com/sd/clients/thermcer.html. Thermal Ceramics FireMaster FastWrap XL is a flexible high temperature insulation rated to 2192°F (1200°C) that is fully encapsulated in FSP facing. The duct enclosure system shall be listed by UL and /or ULC per ASTM E 2336, CAN/ULC S144 and ISO 6944 for 1-, 2- and 3-hour rating and zero clearance to combustibles, and tested per ASTM E84 for a flame/ smoke rating less than 25/50. Insulation shall have a nominal thickness of 1-1/2 inches (38 mm) and density of 6 Ibs/ft3 (96 kg/m3). Insulation shall have a R-Value of 7.3 at 75°F. Installation shall be in strict accordance to manufacturers published installation instructions, UL or ULC Listings, and shop drawings. FastDoorTM XL shall be used for duct access where specified or as required by code. www.morganthermaIceramics.com 12:2014 Page 1 of 8 11Morgan CAdvanced Materials I 4. Physical Characteristics Units/ Wt./ Product Unit Size Ctn. Ctn. FastWrap XL Roll 1-1/2" x 24" x 25' 1 37.5 lbs. FastWrap XL Roll 1-1/2" x 48" x 25' 1 75 lbs. 5. Performance Specifications Reference Standard Standard No. Performance Grease Duct Enclosure ASTM E2336 Pass System Section 16.1 - ASTM E136 Pass Non -Combustibility Section 16.2-Fire Resistance ASTM E119 Pass (wall) Section 16.3 - Durability Test ASTM C518 Pass Section 16.4 - Internal Fire ASTM E2336 Pass Test Section 16.5 - Fire Engulfment ASTM E814/ (duct) E119 pass ULC Grease Duct Test Pass Protocol Standard Methods of Fire CAN/ULC Resistance Tests - Grease Pass S144 Duct Assemblies Grease Duct Clearances UL 1978 Pass Air Ventilation Duct Enclosure ISO 6944 Pass Surface Burning ASTM E84 <25/50 Characteristics Thermal Resistance ASTM C518 7.3 per layer (R-value @ 75°F) Mold Growth ASTM C1338 ULE Validated CA Standard Low VOCs ULE Validated 01350 6. Listings/Building Code Reports Listed Uses Agency Listing Layers Grease Duct Enclosure per UL G18 ASTM E2336 and AC101 (2006, 2 2009, 2012 IMC, NFPA 96, ICC-ES ESR 2213 UMC, CMC) ULC Grease Duct Test Protocol ULC FRD 4, 7* 2 and CAN/ULC S144" Grease Duct Insulation OPL TC/BI 120-01 1 (2003 IMC) Through Penetration FireStop UL System per ASTM E814, See Figure 2 1 or 2 UL 1479 ULC UL HNLJ.V1, 1- or 2-hour Ventilation Duct 19,29 1 FRD 3, 5, Enclosure per ISO 6944-1985 ULC 6, 18 3-hour Ventilation Duct UL HNLJ.V2 2 Enclosure per ISO 6944-1985 Electrical Circuit Protective UL FHIT.5 2 System 7. Storage Thermal Ceramics FastWrap XL must be stored in a dry warehouse environment on pallets. Pallets should not be stacked. 8. Installation Thermal Ceramics FastWrap XL shall be installed by a qualified contractor in accordance with manufacturer's instructions and laboratory design listings. Materials and Equipment • Thermal Ceramics FastWrap XL blanket • Aluminum foil tape • Glass filament reinforced tape (optional) • Carbon steel or stainless steel banding material, minimum 1/2" (13mm) wide, minimum 0.015" (0.4mm) thick, with steel banding clips • Hand banding tensioner and crimping tool • Minimum 12 gage (3mm) steel insulation pins; steel speed clips, minimum 1-1/2" (38mm) square or 1-1/2" (38mm) diameter, or equivalent sized cup -head pins; • Capacitor discharge stud gun • Thermal Ceramics FastDoorTM XL • An approved firestop sealant www.morganthermaIceramics.com 12:2014 Page 2 of 8 11Morgan CAdvanced Materials General Cut edges of the blanket shall be taped with aluminum foil tape to prevent exposed edges of the insulation absorbing grease and moisture in the event of a compromised grease duct joint or condensation. Overlaps and/or tightly butted joints are used to block heat transfer in the event of duct deformation resulting from thermal expansion. Filament tape is suggested to hold the blanket in place until steel banding or pinning is installed to permanently secure the blanket. A. Installation on Grease Duct per ASTM E2336 and CAN/ULC S144 (Figure 1) System requires two layers of insulation applied directly to the duct with tight butt joints at all seams on both layers. The first layer of insulation is cut to a length sufficient to wrap around the duct and provide a tight butt joint where the blanket ends meet. Adjacent blankets on the first layer are butted tightly together with longitudinal seams offset minimum 6" (150mm). The second layer of insulation is installed in the same method as the first layer, with seams between layers offset a minimum of 6" (150mm). Banding and/or pinning per Section D is used to permanently secure the insulation to the duct. B. Installation on HVAC Duct per ISO 6944 (Figure 1) System requires one layer of insulation applied directly to the duct with 3" (75mm) overlaps at all seams. The insulation is cut to a length sufficient to wrap around the duct and provide a 3" (75mm) overlap where the blanket ends meet. Adjacent blankets are installed to provide a minimum overlap of 3" (75mm). Banding and/or pinning per Section D is used to permanently secure the insulation to the duct. C. 2 & 3 Sided Wrap Installation (Figure 4) When space does not allow for a complete wrap applied to the duct on all four sides, the FastWrap XL is approved for 2 or 3 sided installations with mechanical attachment to a rated concrete or CMU assembly. (See Figure 4 for installation details.) D. Mechanical Attachment Methods 1) Banding (Figure 1) - Minimum 1/2" (13mm) wide carbon steel or stainless steel banding, 0.015" (0.4mm) thick, is placed around the entire perimeter of the insulated duct on maximum 10-1/2" (270mm) centers and 1-1/2" (38mm) from each blanket edge or 1-1/2" (38mm) from each collar edge when using the butt joint F/RE��TER 1■1 and collar method. The banding is placed around the blanket and tightened to firmly hold the FastWrap XL in place against the duct, but not cause any cutting or damage to the blanket. 2) Pinning - Pinning on all sides of the duct may be used as an alternative to banding. For ducts wider than 24" (610mm) pinning is required on the bottom of horizontal runs, or on one side of vertical runs (in addition to steel banding). When applicable, 12 Gage (0.4mm) steel pins are installed on 12" (305mm) centers along the width of the duct and 10-1/2" (270mm) centers along the length of the duct. Pins that extend beyond the outer blanket layer shall be turned down or the excessive length cut off to prevent sharp edges. Shoot through pins (cup head pins) may be used in conjunction with steel banding to prevent blanket sag. E. Access Doors 1) FastDoor TM XL (Figure 3) - FastDoor XL is a UL Listed, liquid tight duct cover panel supplied complete with a single layer insulation cover per UL Listing HNKT G18. The FastDoor XL is installed per included installation instructions. No field welding is required. 2) Field Fabricated Access Doors - Each access door assembly has four threaded rods 1/4 inch (6mm) in diameter and 5" (127mm) in length, with one welded to each corner of the door opening. Hollow steel tubes, 4-1/2" (114mm) long are installed outside the access cover plate and over the threaded rods. Four 12 gage (3mm) and 4-1/2" (114mm) long steel insulation pins are welded to the access cover plate to allow for installation of the three layers of FastWrap XL. One layer of FastWrap XL is cut to approximately the same size as the access panel, and impaled over the insulation pins on the panel. A second layer of FastWrap XL is cut so as to overlap the first layer a minimum of 1-1/2" (38mm). It is essential that the first and second layer fit tightly against the surrounding wrap with no through openings. The third and outside layer should be cut to overlap the second insulation layer by a minimum of 1-1/2" (38mm). Minimum 1-1/2" (38mm) round or square insulation clips are installed on the insulation pins to secure the three layers of insulation to the access cover plate. All cut edges of the insulation shall be taped with minimum 3" (75mm) wide aluminum foil tape. Wing nuts and washers are installed on the four threaded rods, and tightened against the hollow steel tubes to seal the www.morganthermaIceramics.com 12:2014 Page 3 of 8 11Morgan CAdvanced Materials Ob.- access cover plate to the duct. F. Through Penetration Firestop System (Figure 2) - When the duct penetrates a fire rated assembly an approved fire stop system must be employed. Figure 2 provides a complete list of UL / ULC firestop design listings which can be found in the Certifications Directory at www.ul.com for US systems and www.ulc.ca for Canadian systems. Prior to installing any firestop system the surfaces of all openings and penetrating items must be clean and dry. The FastWrap XL core blanket (or mineral wool where allowed by the firestop design listing) must be compressed into the annular space. The packing material must be recessed a minimum depth from the surface of the concrete or gypsum assembly. The recessed opening must be filled with a minimum thickness of an approved firestop sealant. The packing material type and compression, minimum recess (typically 1/4" (6mm)), and approved firestop sealant and thickness (typically 1/4" (6mm)) shall be as specified in an approved UL / ULC firestop design listing. When there is not sufficient annular space around the duct to run the FastWrap XL enclosure system continuous through the fire rated assembly, the enclosure may terminate above and below the floor/ceiling assembly or on either side of a wall assembly as shown in Figure 2. When this method is used, the FastWrap XL must be mechanically attached on either side of the fire rated assembly using one of the attachment methods described in Section D, spaced a maximum of 1-1/2" (38mm) from the fire rated assembly. G. Support Hanger Systems 1) Grease ducts: Trapeze support hangers shall be spaced on maximum 60 in. (1500 mm) centers. Hanger rods or straps shall be anchored with steel drop in or wedge expansion type masonry anchors. No additional protection is required for hangers and supports meeting the requirements of the Table below. Hanger Cross Maximum Trapeze Support (or Section Perimeter, in (mm) equivalent Yield Strength), in mm 38 in (10 mm) threaded rod 148 (3759) 2 (51) x 2 (51) x 1,8 (3) in angle 2) HVAC ducts: Trapeze support hangers shall be spaced on maximum 60 in. (1500 mm) centers. Hanger rods or straps shall be anchored with steel drop in or wedge expansion type masonry anchors. No additional F/RE��TER protection is required for hangers and supports meeting the requirements of the Table below. Max. Perimeter, Trapeze Support (or Hanger Cross Section in (mm) equivalent Yield Strength), in (mm) 1 in x 16 gage strap 100 (2540) (25 mm x 1.5 gage strap) A in (6 mm) threaded rod 50 (1270) 1h (38) x 1% (38) x 3/16 (5) angle 38 in (10 mm) threaded 150 (3810) 1h (38) x 1% (38) x 316 (5) rod le angle 12 in (12.7 mm) threaded 218 (5540) 2 (51) x 2 (51) x 14 (6) angle rod 9. Maintenance and Repair No maintenance is required when installed in accordance with Thermal Ceramics (TC) installation instructions. If damage is limited to the foil facing, aluminum foil tape can be used to repair the foil facing. If an area of blanket is found to be damaged the following procedure must be in- corporated. If the damaged area is larger than 8" (203mm) x 8" (203mm) the entire wrap section must be removed and replaced according to TC installation instructions. If the damaged area is small (less than 8" (203mm) x 8" (203mm)), the damaged area must be cut away and replaced with a new section 1" (25mm) larger in length and width than the cut out, such that the new section can be compressed tightly into the cut out area. All cut edges of the new section must be taped and sealed with aluminum foil tape. The new section must be held in place with either pinning or banding per TC installation i nstructions. 10. Limitations Thermal Ceramics FireMaster FastWrap XL shall be installed in accordance with these installation instructions and appropriate laboratory design listings. The integrity of FastWrap XL systems is limited to the quality of the installation. * For personal protective equipment recommendations, please see SIDS. Thermal Ceramics, FireMaster, and FastWrap are trademarks of Morgan Advanced Materials. FireMaster products are manufactured by Thermal Ceramics and are distributed by authorized distributors. www.morganthermaIceramics.com 12:2014 Page 4 of 8 UMorgan CAdvanced Materials F/R"94FR qw� Grease and HVAC Duct Enclosure System 1 or 2 Hour Shaft Alternative / Zero Clearance to Combustibles 2 t trz� ae 9 Butt Joint / Butt Joint Typical s TWO LAYER INSTALLATION (Grease Duct perASTM E2336 and CAN/ULC S144) Telescope Wrap Option Butt Joint Option Checkerboard Wrap Option SINGLE LAYER INSTALLATION OPTIONS (2-Hour rated HVAC Duct per UL HNLJ V-19) LEGEND 1 Two Layers of XL Insulation for ASTM E2336 and CAN/ULC S144 Grease Duct Enclosures One La er of XL Insulation for 2-Hour Air Ventilation Duct Enclosures 2 Steel banding minimum 1/2" 13 wide by 0.015" 0.4 thick. 3 Tight butt joints no overlap at perimeter and longitudinal joints, both layers for grease ducts 4 Min. 3" 75 overlap on perimeter and between adjacent blankets 5 Optional 6" XL collar 6 Hangers - size dependent weight of assembly see datasheet Section G 7 Trapeze Supports - size dependent on weight of assembly see datasheet Section G 8 1 Steel Rectangular or Round Duct size, gage and construction dependent per Listed Desi n The integrity of Thermal Ceramics duct systems is limited to the quality of the installation. XL001-10 www.morganthermalceramics.com 12:2014 Page 5 of 8 UMorgan CAdvanced Materials F/R"7ER" Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System Through Penetration Firestop Systems XL Insulation continuous through rated wall assembly XL insulation terminated on both sides of the rated wall assembly XL Insulation continuous through rated floor/ceiling assembly Packing XL insulation terminated at the top and bottorri surface of the floor/ceiling assembly Firestop Designs per ASTM E814 / UL 1479 - Consult UL / ULC Directories for System Details UL Listing F- & T-Rating1 FloorNVall 2 Penetrant 3 Enclosure Per 4 Termination 5 Firestop Sealant Details C-AJ-7012 2-hour Concrete/CMU 8424; 26 Ga Duct V19; FRD3; 5; 18 wrap through 1/2 in; STI; Tremco C-AJ-7014 3-hour Concrete/CMU 84x24; 26 Ga Duct V2; wrap through 1/2 in; STI; Tremco C-AJ-7019 1 or 2-hour Concrete/CMU 84x24; 26 Ga Duct V19; FRD3, 5, 18 terminate at 1/4 in; STI; Tremco C-AJ-7021 2-hour Concrete/CMU 49x24; 16 Ga Duct G18; FRD4; 7 terminate at 114 in; STI; Tremco C-AJ-7095 2-hour Concrete/CMU 39x39; 22 Ga Duct V19; FRD3, 5, 18 wrap through 1/4 in; STI Hilti; Rectorseal; Tremco C-AJ-7098 2-hour Concrete/CMU 49x24; 16 Ga Duct G18; FRD4; 7 wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco F-C-7036 1 or 2-hour Wood/Gyp Floor 24x12; 16 Ga Duct G18; FRD4; 7 wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco F-C-7055 1-hour Wood/Gyp Floor 4 Dia; 30 Ga Duct V29; FRD28 wrap through 1/4 in; STI W-J-7086 2-hour Concrete/CMU Wall 100x100; 26 Ga Duct V19; FRD3;5; 18 terminate at 1/4 in; STI W-L-7121 1 or 2-hour Gyp Wall 30x30; 16 Ga Duct G18; FRD4; 7 wrap through 1/4 in; STI; Hilti; Rectorseal; Tremco W-L-7145 1 or 2-hour Gyp Wall 100x100; 26 Ga Duct V19; FR133; 5; 18 terminate at 5/8 in; STI The integrity of Thermal ceramics duct systems is limited to the quality of the installation. XL0035 www.morganthermalceramics.com ir 12:2014 Page 6 of 8 11Morgan CAdvanced Materials 4 NI ASTM E 2336 Compliant Enclosure and Door System FIGURE 3 1 UL listed FastDoor XL access panel 2 All Thread Rods and wing nuts 3 Retainer Clips with threaded nut and wing bolts 4 Insulation layers as required by UL or ITS Listings 5 FastDoor XL; 1-1/2 inch thick single layer insulation F/R"STER FastDoor XL1 Access Doors Sizes Available Opening Sizes Ordering Code 10" x 4" Door Opening *434-6970-033-99X1 10" x 6" Door Opening 434-6970-034-99X1 12" x 8" Door Opening 434-6970-035-99X1 12" x 12" Door Opening 434-6970-036-99X1 16" x 12" Door Opening 434-6970-037-99X1 20" x 20" Door Opening 434-6970-038-99X1 *Special Order; Curved and SS Available www.morganthermalceramics.com 12:2014 Page 7 of 8 UMorgan CAdvanced Materials F/R"94FR 19� Commercial Kitchen Grease Duct Enclosure System Air Ventilation Duct Enclosure System 1 Or 2 Or 3 Hour Shaft Alternative / Zero Clearance to Combustibles 2 and 3 Sided Wrap Detail for Attaching to Walls and/or Ceilings XL005-4 Note: Ducts must be independently supported per code LEGEND 1 Rated Concrete floor/ceiling, or wall - with rating equal or greater than enclosure rating 2 Two layers of XL Insulation for Grease Duct Enclosures (install per UL G18)) One layer of XL Insulation for Air Ventilation Duct Enclosures (install per UL V19) Two layers of XL Insulation for 3-hr Air Ventilation Duct Enclosure (install per UL V2) 3 Concrete fastener system 4 3/16" (5) thick x 2" (50) -3" (75) wide bar stock perforated 12" (305) o.c. 5 8" (203) maximum Air Gap 6 Duct 7 Steel banding min. 1/2" (13) wide by 0.015" (0.4) thick. 8 Banding clip The integrity of Morgan Thermal Ceramics duct systems is limited to the quality of the installation. www.morganthermalceramics.com 12:2014 Page 8 of 8