REVIEWED BLD-BLD2021-1694+WSEC-HEATING+12.14.2021_4.58.25_PM+2573082
REVIEWED BY CITY OF EDMONDS € BUILDING DEPARTMENT BLD2021-1694 RECEIVED Dec 20 2021 CITY — EDMONDS Simple Heating System Size. Washington State DEVELOPMENT SERVICES RTMENT This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Drew Accessory Dwelling Unit 17715 Talbot Rd, Edmonds, WA 98026 Heating System Type: o All Other Systems Contact Information Patricia Albert, Architect pattyalbertarchitect@msn.com 206-949-1758 6707 1s Ave NW, Seattle, WA O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions Design Temperature Difference (AT) Edmonds 4T =Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 670 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.01 5,360 Glazing and Doors U-Factor X Area = UA Instructions _u-o.za - l 0.280 131 36.68 Skylights U-Factor X Area = UA Instructions 0.50 0 --- Insulation Attic U-Factor X Area = UA Instructions "R-38Advanced -4 0.026 1 670 17.42 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA `Select R-Value No selection 0 --- Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions L Select R-Value ] No selection 654 Floors U-Factor X Area UA Instructions R-30 0.029 670 19.43 Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions Select R-value . No selection 0 --- Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions Select conditioning � No selection 0 --- Slab on Grade (see Figure 1) F-Factor X Length UA Instructions Select R-value � No selection 0 --- Location of Ducts Instructions Duct Leakage Coefficient Unconditioned Space 1.10 Figure 1. Above Grade "Mmo- Sum of UA 73.53 Envelope Heat Load 3,382 Btu / Hour Sum of UA x AT Air Leakage Heat Load 2,663 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 6,045 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 6,650 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 8,312 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07101113) Window, Skylight and Door Schedule Project Information Drew Accessory Dwelling Unit Additon 17715 Talbot Rd, Edmonds, Wa 98026 Ref. U-factor Exempt Swinging Door (24 sq. ft. max.) JA 10.42 Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component DOUBLE HUNG 2 0.28 XX DOUBLE HUNG 3 0.28 CASEMENT, EGRESS 4 0.28 DOUBLE HUNG 5 0.28 HORIZ. SLIDER 16 10.28 DOUBLE HUNG, KITCHEN 17 10.28 Contact Information Patricia Albert, Architect patty albert architect@msn.com 206-949-1758 6707 1st Ave NW, Seattle, WA 98117 Width Height Qt. Feet Inch Feet Inch Width Height Ot FPPt Inch FPPt Inch ©©EM© MMEME M©EME ©©EME M©E©E M©E©E --E-E --E-E --E-E --E-E --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ --■-■ Area HA 11 111 Area IIA ' 1 ' 1 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area Overhead Glazing (Skylights) Component Description Ref. U-factor Width Height Qt. Feet Inch Feet Inch Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA/Area Total Sum of Fenestration Area and UA (for heating system sizing calculations) 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 110.0 30.80 0.28 Area UA 11 111 11 111 11 111 11 111 11 111 11 111 11 111 1 11 131.0 39.62