Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-0610_Manufacturer_Specifications_and_Installation_Instructions_5.18.2023_1.30.43_PM_3554446
Job Name: System Reference: Date: Indoor Unit.PVA-A36AA7 .............................................................................. Outdoor Unit PUZ-HA36NKA ........................................................................ ,ao►Illllllllllllllllllllulll�,,�,,.: �ldlllllllllllllllllllllllllllllllllllllllllll, �Illlllllllllllllllllllllllllllllllllllllllllllllld IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII�''' lo�llllllllllllllllllllllloo��� :I - �dlllllllllllllllllllllllllllllllllllllllllil� IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII�� Illllllllllllll 111111111111111111111111111' .M INDOOR UNIT FEATURES • Ducted air handler provides a solution to cool and heat large zones • Highly efficient totally enclosed ECM motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and boosts efficiency • Positive pressure cabinet with air leakage of less than 1.0% at 1.0 in.WG • Unique blow through design allows simple coil cleaning when the blower is removed • Multi -position installation: horizontal (left or right), vertical (up or down). For downflow configurations, the CMA-1 is recommended for proper management of condensate to prevent water blow -off in certain conditions • Optional electric heat kit for additional heat capacity • Optional humidifier control and ERV control • Multiple control options available: o kumo cloud® smart device app for remote access o Third -party interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • Variable speed INVERTER -driven compressor • High heating capacity: flash injection circuit maintains 100% heating capacity at 5°F outdoor temperature • Wide heating range: heating performance down to -13°F (average of 80% heating capacity) • High speed heating at start up: Hyper -Heating INVERTER® reduces the time for heating at start up by about half compared to standard models • Suction accumulator pre -charged with refrigerant volume for piping length up to 100 ft. • High pressure/temperature protection • Built-in base pan heater • Flash injection circuit provides efficient high heating capacities at low ambient temperatures Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input Rated Power Input Moisture Removal BTU/H 36,000 BTU/H 33,000 BTU/H 15,500 W 2,800 W 2,500 Pints/h 3.8 Sensible Heat Factor 0.87 Power Factor [208V / 230V1 % 90.0 / 90.0 Heating at 47°F' Maximum Capacity BTU/H 40,000 Rated Capacity BTU/H 38,000 Minimum Capacity BTU/H 18,600 Maximum Power Input W 3,070 Rated Power Input W 2,850 Power Factor [208V / 230V1 % 91.0 / 91.0 Heating at 17°F3 Maximum Capacity BTU/H 38,000 Rated Capacity BTU/H 24,600 Maximum Power Input W 4,895 Rated Power Input W 2,825 Heating at 5°F" Maximum Capacity BTU/H 38,000 Maximum Power Input W 5,565 Heating at -13°F7 Maximum Capacity BTU/H 30,400 Efficiency SEER I SEER2 18.2 1 18.2 EER' I EER2' 13.0 1 13.2 HSPF [IV] I HSPF2 [IV] 11.2 1 10.0 COP at 47°F2 3.9 COP at 17°F at Maximum Capacity3 2.3 COP at 5°F at Maximum Capacity' 2.0 Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 198 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 35 Recommended Wire Size [Indoor - Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit Indoor Unit MCA A 5.63 Fan Motor Full Load Amperage A 4.40 Fan Motor Type DC Motor Airflow Rate at Cooling, Dry CFM 788-956-1,125 Airflow Rate at Heating, Dry CFM 788-956-1,125 Sound Pressure Level [Cooling] dB[A] 30-3"8 Sound Pressure Level [Heating] dB[A] 30-34-38 External Static Pressure in.WG 0.30-0.5-0.8 Drain Pipe Size In. [mm] 3/4 FPT [19.05] Coating on Heat Exchanger — External Finish Color Galvanized steel cabinet -Powder coated Slate Gray Unit Dimensions W x D x H: In. [mm] 25 x 21-5/8 x 59-1/2 [635 x 548 x 1,511] Package Dimensions W x D x H: In. [mm] 13-7/16 x 34-11/16 x 65 [340 x 880 x 1,650] Unit Weight Lbs. [kg] 172 [78] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 72 WB 166 DB, 61 WB Heating Intake Air Temp [Maximum / Minimum] °F 77 DB / 59 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 7Heating at -13°F (Indoor // Outdoor) °F 70 DB, 60 WB H -13 DB, -14 WB * Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): Wind baffles required to operate below 23°F DB in cooling mode. Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP Fan Motor Output Airflow Rate [Cooling / Heating] A 24.0 A 40 W 74 CFM 3880 / 3880 Refrigerant Control LEV Defrost Method Reverse Cycle Sound Pressure Level, Cooling' dB(A) 52 Sound Pressure Level, Heating2 dB(A) 53 Compressor Type Scroll Compressor Model ANB33FJMMT Compressor Rated Load Amps A 18 Compressor Locked Rotor Amps A 27.5 Compressor Oil [Type // Charge] oz. FV50S // 1.4,47 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Built-in Unit Dimensions W x D x H: In. [mm] 41-5/16 x 14-3/16 x 52-11/16 [1050 x 360 x 13381 Package Dimensions W x D x H: In. [mm] 43 x 18 x 57 [1110 x 480 x 1440] Unit Weight Lbs. [kg] 261 [118] Package Weight Lbs. [kg] 285 [129] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 0 DB Heating Air Temp [Maximum / Minimum] °F 70 DB, 59 WB / -13 DB, -13 WB Heating Thermal Lock -out / Re -start Temperatures** °F -22 / -13 Refrigerant Type R410A Pre -Charged Refrigerant Amount Lbs, oz 11.0, 7.0 Maximum Pre -Charged Piping Length Ft. [m] 100.0 [30.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] .7 [56] Piping Gas Pipe Size O.D. [Flared] In.[mm] 518 [15.88] Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52] Maximum Piping Length Ft. [m] 245 [75] Maximum Height Difference Ft. [m] 100 [30] Maximum Number of Bends 15 NOTES: AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB H 5 DB, 4 WB 7Heating at -13°F (Indoor H Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB * Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]): Wind baffles required to operate below 23°F DB in cooling mode. Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 3-Pin Connector ❑ PAC-715AD Airzone ZBS Wired Blueface Principal Controller White ❑ AZZBSBLUEFACECB Airzone ZBS Wired Blueface Principal Controller White ❑ AZZBSBLUEZEROCB Airzone ZBS Wired Lite Controller White ❑ AZZBSLITECB Airzone ZBS Wireless Lite Controller White ❑ AZZBSLITERB Control Interface Airzone ZBS Wireless Think Controller White BACnet® and Modbus® Interface Connector cable for remote display ❑ AZZBSTHINKRB ❑ PAC-UKPRC001-CN-1 ❑ PAC-SA88HA-EP IT Extender ❑ PAC-WHS011E-E kumo station® for kumo cloud® ❑ PAC-WHS01 HC-E Remote Operation Adapter= ❑ PAC-SF40RM-E Thermostat Interface ❑ PAC-US444CN-1 Thermostat Interface ❑ PAC-US445CN-1 USNAP Adapter ❑ PAC-WHS01UP-E Flush Mount Remote Temperature Sensor ❑ PAC-USSEN002-FM-1 Flush Mount Temperature Sensor ❑ PAC-USSEN001-FM-1 Remote Sensor Remote Temperature Sensor ❑ PAC-SE41 TS-E Wireless temperature and humitity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Deluxe Wired MA Remote Controllert ❑ PAR40MAAU Simple Ductless Wired Remote Controller ❑ PAC-SDW01 RC-1 Wired Remote Controller Simple MA Remote Controllert ❑ PAC-YT53CRAU-J Touch MA Controllert ❑ PAR-CT01 MAU-SB kumo touch' RedLINK' Wireless Controller ❑ MHK2 Lockdown bracket for remote controller ❑ RCMKPICB Wireless Remote Controller Wireless MA Receiver ❑ PAR-FA32MA-W Wireless MA Remote Controller ❑ PAR-FL32MA-E Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor ❑ X87-835 Condensate Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H ❑ COMBI 20/2PR, 1 PR shielded + 1 PR plenum wire for Airzone, 100 Itreel ❑ CW2042S2-100 Control Wire 20/2PR, shielded + 1PR plenum wire for Airzone, 500 ft reel ❑ CW2042S2-500 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Downflow Kit Condensate Management Kit for downflow installation ❑ CMA-1 Electric Heat Lockout Electric Heat Lockout ❑ ETC-211020-MIT 10kW Electric Heater ❑ EH10-MPA-LB Electric Kit Heats 15kW Electric Heater ❑ EH15-MPAS-LB 17kW Electric Heater ❑ EH17-MPAS-LB 10' x 3/8" x 10' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-10 100' x 3/8" x 100' x 518" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-100 15' x 318" x 15' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-15 Lineset 30' x 3/8" x 30' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-30 50' x 3/8" x 50' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-50 65' x 3/8" x 65' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-65 Terminal Block Separate Terminal Power Block ❑ SPTB1 NOTES: *PAC-SF40RM-E (Unable to use with wireless remote controller) Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide (1 Piece) Central Drain Pan Control/Service Tool Hail Guard M-NET Converter M-NET Converter Condensing Unit Mounting Pad: 24" x 42" x 3" Optional Defrost Heater 18" Dual Fan Stand ❑ PAC-SH96SG-E (two pieces are required) Centralized Drain Pan ❑ PAC-SH97DP-E Control/Service Tool ❑ PAC-SK52ST Hail Guards ❑ HG-A2 M-NET Converter ❑ PAC-SJ85MA-E ❑ PAC-SJ95MA-E Mounting Pad ❑ ULTRILITE2 Optional Defrost Heater ❑ PAC-SJ20BH-E ❑ QSMS1802M 24" Dual Fan Stand ❑ QSMS2402M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1202M Wind Baffle Front Wind Baffle ❑ WB-PA3 (two pieces are reauired) Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. To p view 626 Kno ckout Hole o26 Kno ckout Hole (Indoor / Outdoor unit connection) (Remote controller transmission) Unit:mm(in. ) Note 1.K eep the ser vice space for maintenance at the front . F rc C Bol Right side view Model ®Nominal Filter Size Duct Connection 12 KBTUIH 508 x 406.4 x 25.4 376 x 402 18 KBTU/H 20 x 16 x 1 14-13I16 x 15-7/8 24 KBTU/H 508 x 508 x 25.4 477 x 402 30 KBTUIH 20 x 20 x 1 18-13/16 x 15-7/8 36 KBTU/H 508 x 609.6 x 25.4 579 x 402 42 KBTUIH 20 x 24 x 1 22.13/16 x 15-7/8 U.K. mm 6. i Model A B C D E F G H J ®Gas Pipe ®Liquid Pipe 12 KBTU/H 18 KBTU/H 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8-7/8) 1275 (50-114) 680 (26-13116) 823 (32-7116) 735.5 (29) 360 (143/18) 0112.7 (1/2) 416.35 (1/4) 24 KBTUIH 30 KBTU/H 534 (21) 477 (18-13/16) 382.6 (15.1/8) 266.5 (10.1/2) 1378 (54-114) 737 (29-1116) 953.5 (373YI6) 792 (313116) 461 (18.3116) 36 KBTU/H dt 15.88 (SIS) m 9.52 (3l8) 42 KBTUIH 635 (25) 579 (22-13116) 484.6 (19.1/8) 317.5 (12.1/2) 1511 (59.1/2) 798.5 (31.7/16) 1053 (41.1/2) 853.5 (33.5/8) 563 (223116) Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 1 FREE SPACE (Around the unit) The diagram below shows a basic example. Explanation of particular details are given in the installation manuals etc. C C 2 SERVICE SPACE 3 FOUNDATION 30LTS Dimensions of space needed Please secure the unit firmly for service access are with L foundation IN10<W3/8>I balls. shown in the below diagram. (Baits and washers must be purchased locally.) Example of Notes Q. . . Refrigerant GAS pipe connection (FLARE)015.88(5/8F). Q2 -Refriggerant LIQUID pipe connection (FLARE)09.52(3/8F). "7 Indication of VALVE connection location. Piping Knock -Out Hole Detailes 4 PIPING -WIRING DIRECTIONS Piping and wiring connections can be made from 6 directions: FRONT, Right, Rear and Below. MIR MAN iJ _ail' M■r ��v 00 CD O O OW w< N N N (n N 7 CD CID o S ^� < D rD m �1 P w X- ° N 3 3 3 A V V