Loading...
APPROVED BLD BLD2023-0453+Mechanical_Plan+4.12.2023_9.46.42_AM+3478397RECEIVED 4/12/2023 LEGEND AND ABBREVIATIONS HP - 1,2 - heat pump outdoor units IU - 1,2,3,4 - indoor units AH-1 - air handler RL - refrigerant line RS - refrigerant suction line n.wv-- Flexible duct o 6 Outlet grill ICJ Return air CD - condensate drain CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT City Of Edmonds Building Department Work 2 HEAT PUMPS •--_-_------------ Address 20919 76TH AVE W Owner, SPROUTS PRESCHOOL Approved Date; _ 04/19/2023 Building Official: Eri.G Coder ------------------------ Permit Number BLD2023-0453 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES RECEIVED 4/1212023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT r" 4ixl0 N 20919 76th Ave W, Edmonds. Mechanical floor plan. N 20919 76th Ave W, Edmonds. DADU. Indoor units plan view. RECEIVED 4/12/2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT RECEIVED 4/12/2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HVAC SCHEDULE 11P-AT r%11■Ar% A1P9 11 A\I11I rr1 A1111r-11111 r TAG MANUF MODEL 1 IL-r-1I 1 LIY11 11Y LLVVI P11\ I Ir1 ✓I\ l "L.FW6." CAPACITY ELECTR. SEER WEIGHT NOISE NOTE COOLING(BTU) HEATING(BT ) V PHASE MCA BREAKER HP-1 MITSUBISHI MXZ5C42NA 43000 24400 30 1 32.5 40 19 189 56 1 HP-2 MITSUBISHI MXZ2C20NA 20000 15500 230 1 20 20 16 126 50 1 AH-1 MITSUBISHI SVZKP18NA 18000 21600 30 1 3 15 18 93 55 1 Notes; 1. Power wiring, conduit and disconnect by E.C. 2. With R-410 refrigerant 3. Refrigerant line connection sizes - %" gas, '/a' - liquid, 4. Field verify available voltage and phase. INDOOR UNITS SCHEDULE TAG I MANUF. IMODEL I COOLING HEATING I SEER I HSPF I EER I V/O IMCPIMOCP WT IU-1,2,3,41 MITSUBISH11 MSZGL121 13600 12000 1 23 12.5 230/1L 11 12 26 Notes; 1. Verify refrigeration pipe sizing 2. Units must be properly leveled for condensate removal 3. Rise of condensate pipelines not be exceed 19" 4. Condensate piping by pc ROUTE ORAiN x DVSCHARI WITH AIR AIR GAP t-,-�-COND.ENSING UNIT DETAIL _ SCALE: NTS (3/81 FOUNDATION DOLT RECEIVED 4/12/2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Noise information sheet MXZ5C42NA (HP-1) - 56 dB - sound rating The distance from the outdoor unit to the nearest building property line 207, the distance correction factor 23.5 dB. 56dB - 23.5dB =32.5 dB. MXZ2C20NA(HP-2) - 50 dB - sound rating. The distance from the outdoor unit to the nearest building property line 14', the distance correction factor 21 dB. 50 dB - 14 dB = 36 dB. Acoustic report not required. RECEIVED 4/12/2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT