ELECTRICAL DATA
UNIT SIZE - SERIES
(VOLTAGE)
V/PH
OPER VOLTS*
COMPR
FAN
MCA
MAX FUSE** or
CKT BRK AMPS
MAX
MIN
197
LRA
RLA
FLA
018-A (N)
208/230/1
253
56.3
9.0
0.50
11.8
20
024-A N
62.9
10.9
0.50
14.1
25
030-A N
73.0
14.1
0.70
18.3
30
036-A N)
77.0
14.1
1.20
18.8
30
048-A (N)
124.0
18.5
1.2o---T
24.3
40
060-A N
152.5
23.7
1.45
31.1
50
036-A (P)
208/230/3
253
197
71.0
9.0
1.20
12.5
20
048-A (P)
83.1
13.7
1.20
18.3
30
060-A P
110.0
15.9
1.45
21.4
35
036-A E)
460/3
506
414
38.0
5.6
0.60
7.6
15
048-A (E)
41.0
6.2
0.60
B.4
15
060-A (E)1
52.0
7.1
1 0.80
1 9.7
15
Lizut=Nu:
FLA - Full Load Amps
HACR - Heating, Air Conditioning, Refrigeration
LRA - Locked Rotor Amps
NEC - National Electrical Code
RLA - Rated Load Amps (compressor)
• Permissible limits of the voltage range at which the unit will operate satisfactorily
•' Time -Delay fuse.
Complies with 2007 requirements of ASHRAE Standards 90.1
A -WEIGHTED SOUND POWER (dBA)
Unit Size
1 B
Standard
Rating
(dBA)
69
66
125
50.5
50.5
250
57.0
58.5
Typical Octave Band
500
59.5
60.5
Spectrum (dBA,
1000
64.5
59.5
without tone adjustment)
2000
60.5
56.5
4000
53.5
51.0
8000
43.0
41.5
24
30
68
55.5
59.5
61.5
63.5
60.0
58.0
49.5
36
71
59.5
59.5
62.0
65.5
63.5
62.0
55.0
48
70
57.5
59.5
64.0
66.0
63.0
60.5
54.5
60
73
60.0
61.5
64.5
67.0
1 66.0
6NN
I 58.0
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).
A
A -WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD
Unit Size
Standard
Rating
(dBA)
I Typical Octave Band Spectrum (dBA, without tone adjustment)
j
I 125
250
Soo
1000
2000
4000
8000
16
68
52.5
58.0
58.5
64.5
59.5
52.5
42.5
24
65
54.5
57.5
59.5
59.0
56.0
50.5
40.5
30
68
55.0
60.0
61.5
62.5
60.0
58.0
49.5
36
71
59.5
59.5
62.5
65.0
63.0
61.5
55.0
48
70
57.5
59.5
63.0
65.0
62.5
60.0
54.0
60
73
61.0
62.0
64.0
67.0
1 65.5
65.5
57.5
NOTES:
Tested in accordance with AHRI Standard 270-08 (not listed in AHRI).
Accessory sound shield will not accommodate unit sizes 18 and 24.
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)
UNIT SIZE -SERIES I REQUIRED SUBCOOLING ° F (
18
k 24
12
12
30
12
36
8
48
60
12
10
7
DIMENSIONS - ENGLISH
n
00
®m
r
fr
O
r
fr
O
c�
c
m
d
x _ YES
N
m
1.
O=NO
N
pp
N
N
MINIMUM
UNIT SIZE
MOUNTING PAD
DIMENSIONS
18.24
23" X 42"
3D.36.48,60
24" X 50"
1 CLEARANCE REQUIREMENTS• SINGLE UNIT APPLICAIIONS: WITH COIL FACING WALL• ALLOW 6 IN. MINIMUM CLEARANCE
ON COIL SIDF AND COIL END AND 2D 1N MINIMUM CLEARANCE ON FAN SIDE WITH FAN FACING WALL' ALLOW B If"
MINIMUM CLEARANCE ON FAN SIDE AND 6 IN ON COIL LNO AND 20 IN MINIMUM CLEARANCE ON COIL 'IDE.
MULII-UNIT APPLICATIONS: ALLOW 24 IN. MINIMUM CLEARANCE BETWEEN FAN AND COIL SIDES OF MULTIPLE UNITS
ARRANGE UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOTHER WHEN TWO UNITS ARE INSTALLED ENO TO END
WITH IRE COIL ENDS FACING EACH OTHER ALLOW 12 IN MINIMUM CLEARANCE BETWEEN UNITS
COMPRESSOR END SERVILE CLEARANCE• ALLOW 24 IN MINIMUM CLEARANCE ON COMPRESSOR END WHEN UNITS AAE STACHED OR
'HERE IS LESS THAN 40 IN OF CLEARANCE ABOVE THE IOP OF THE UNIT, IF THEAE [S 40 IN. CLEARANCE ABOVE UNIT AND
1HE TOP PANEL IS ACCESSIBLE FOR REMOVAL ALLOW 6 IN. MINIMUM CLEARANCE ON GOMPRESSOk ENV FOR SERVICE
IMPURTANI: WHEN INSTALLING SINGLE OR MULTIPLE UNITS IN AN ALCOVE, ROOF WELL• OR PARIIALLY ENCLOSED AREA,
ENSURE THEAE IS ADEOUATE VENTILATION TO PREVENI RECIRCULATION OF DI`�CHARGE AIR.
2 MINIMUM OUT DOOA OPERATING AMBIENT IN COOLING
112, MOUE IJ SS'F, MAX. 125'F.
3. SERIES DESIGNATION IS THE 13TH POSITION OF IHE
UNIT MODEL NUMBER.
4. CENTER OF GRAVITY
4 3116' S. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED.
FIELD CONTROL SUFPLI
WIRE ENTRY
T 1 B" HOLE WIGROMMET
M VAPOR LINE CONN
FEMALE SWEAT CONN.
LI
— 0 3/6" LIOUID LINE
FEMALE SWEAT CONN. —
f—.WNCTION BOX FOR
POWER SUPPLY AND
CONTROL CONNECTIONS
1 Ifl6•
•J�7�
�•T 1 7116'
IELD POWER SUPPLY CONN.
OLE SIZES PROVIDED:
0 T/8" HOLE WITH
0 1 116" NNOG ROUT AND
0 1 316, HNOCNOUI