BLD2023-0631_Manufacturer_Specifications_and_Installation_Instructions_5.23.2023_11.11.27_AM_3563564A ELECTRICAL DATA UNIT SIZE - SERIES (VOLTAGE) V/PH OPER VOLTS* COMPR FAN MCA MAX FUSE** or CKT BRK AMPS MAX MIN 197 LRA RLA FLA 018-A (N) 208/230/1 253 56.3 9.0 0.50 11.8 20 024-A N 62.9 10.9 0.50 14.1 25 030-A N 73.0 14.1 0.70 18.3 30 036-A N) 77.0 14.1 1.20 18.8 30 048-A (N) 124.0 18.5 1.2o---T 24.3 40 060-A N 152.5 23.7 1.45 31.1 50 036-A (P) 208/230/3 253 197 71.0 9.0 1.20 12.5 20 048-A (P) 83.1 13.7 1.20 18.3 30 060-A P 110.0 15.9 1.45 21.4 35 036-A E) 460/3 506 414 38.0 5.6 0.60 7.6 15 048-A (E) 41.0 6.2 0.60 B.4 15 060-A (E)1 52.0 7.1 1 0.80 1 9.7 15 Lizut=Nu: FLA - Full Load Amps HACR - Heating, Air Conditioning, Refrigeration LRA - Locked Rotor Amps NEC - National Electrical Code RLA - Rated Load Amps (compressor) • Permissible limits of the voltage range at which the unit will operate satisfactorily •' Time -Delay fuse. Complies with 2007 requirements of ASHRAE Standards 90.1 A -WEIGHTED SOUND POWER (dBA) Unit Size 1 B Standard Rating (dBA) 69 66 125 50.5 50.5 250 57.0 58.5 Typical Octave Band 500 59.5 60.5 Spectrum (dBA, 1000 64.5 59.5 without tone adjustment) 2000 60.5 56.5 4000 53.5 51.0 8000 43.0 41.5 24 30 68 55.5 59.5 61.5 63.5 60.0 58.0 49.5 36 71 59.5 59.5 62.0 65.5 63.5 62.0 55.0 48 70 57.5 59.5 64.0 66.0 63.0 60.5 54.5 60 73 60.0 61.5 64.5 67.0 1 66.0 6NN I 58.0 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). A A -WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD Unit Size Standard Rating (dBA) I Typical Octave Band Spectrum (dBA, without tone adjustment) j I 125 250 Soo 1000 2000 4000 8000 16 68 52.5 58.0 58.5 64.5 59.5 52.5 42.5 24 65 54.5 57.5 59.5 59.0 56.0 50.5 40.5 30 68 55.0 60.0 61.5 62.5 60.0 58.0 49.5 36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0 48 70 57.5 59.5 63.0 65.0 62.5 60.0 54.0 60 73 61.0 62.0 64.0 67.0 1 65.5 65.5 57.5 NOTES: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). Accessory sound shield will not accommodate unit sizes 18 and 24. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE -SERIES I REQUIRED SUBCOOLING ° F ( 18 k 24 12 12 30 12 36 8 48 60 12 10 7 DIMENSIONS - ENGLISH n 00 ®m r fr O r fr O c� c m d x _ YES N m 1. O=NO N pp N N MINIMUM UNIT SIZE MOUNTING PAD DIMENSIONS 18.24 23" X 42" 3D.36.48,60 24" X 50" 1 CLEARANCE REQUIREMENTS• SINGLE UNIT APPLICAIIONS: WITH COIL FACING WALL• ALLOW 6 IN. MINIMUM CLEARANCE ON COIL SIDF AND COIL END AND 2D 1N MINIMUM CLEARANCE ON FAN SIDE WITH FAN FACING WALL' ALLOW B If" MINIMUM CLEARANCE ON FAN SIDE AND 6 IN ON COIL LNO AND 20 IN MINIMUM CLEARANCE ON COIL 'IDE. MULII-UNIT APPLICATIONS: ALLOW 24 IN. MINIMUM CLEARANCE BETWEEN FAN AND COIL SIDES OF MULTIPLE UNITS ARRANGE UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOTHER WHEN TWO UNITS ARE INSTALLED ENO TO END WITH IRE COIL ENDS FACING EACH OTHER ALLOW 12 IN MINIMUM CLEARANCE BETWEEN UNITS COMPRESSOR END SERVILE CLEARANCE• ALLOW 24 IN MINIMUM CLEARANCE ON COMPRESSOR END WHEN UNITS AAE STACHED OR 'HERE IS LESS THAN 40 IN OF CLEARANCE ABOVE THE IOP OF THE UNIT, IF THEAE [S 40 IN. CLEARANCE ABOVE UNIT AND 1HE TOP PANEL IS ACCESSIBLE FOR REMOVAL ALLOW 6 IN. MINIMUM CLEARANCE ON GOMPRESSOk ENV FOR SERVICE IMPURTANI: WHEN INSTALLING SINGLE OR MULTIPLE UNITS IN AN ALCOVE, ROOF WELL• OR PARIIALLY ENCLOSED AREA, ENSURE THEAE IS ADEOUATE VENTILATION TO PREVENI RECIRCULATION OF DI`�CHARGE AIR. 2 MINIMUM OUT DOOA OPERATING AMBIENT IN COOLING 112, MOUE IJ SS'F, MAX. 125'F. 3. SERIES DESIGNATION IS THE 13TH POSITION OF IHE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY 4 3116' S. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. FIELD CONTROL SUFPLI WIRE ENTRY T 1 B" HOLE WIGROMMET M VAPOR LINE CONN FEMALE SWEAT CONN. LI — 0 3/6" LIOUID LINE FEMALE SWEAT CONN. — f—.WNCTION BOX FOR POWER SUPPLY AND CONTROL CONNECTIONS 1 Ifl6• •J�7� �•T 1 7116' IELD POWER SUPPLY CONN. OLE SIZES PROVIDED: 0 T/8" HOLE WITH 0 1 116" NNOG ROUT AND 0 1 316, HNOCNOUI