BLD2023-0644_Manufacturer_Specifications_and_Installation_Instructions_5.25.2023_8.40.32_AM_3568542
124ANS PREFERRED'"" SERIES AIR CONDITIONER B r yant WITH PURON® REFRIGERANT 1 1/2 TO 5 NONUNAL TONS Product Data � n Preferred TM Bryant air conditioners with Puron o refrigerant provide a collection of features unmatched by any other family of equipment. The 124ANS has been designed utilizing Bryant's Puron refrigerant. This environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth's ozone layer. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up—to—date ratings information. INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency • 14 SEER/11.7 — 12.2 EER (Based on tested combinations) Sound • Levels as low as 66 dBA Design Features • Small footprint • DuraGuard - cabinet — All steel cabinet construction — Mesh coil guard Reliability, Quality and Toughness • Scroll compressor • Factory —supplied filter drier • High pressure switch • Accumulator • Line lengths up to 250' (76.2 m) • Low ambient operation (down to—20°F/-28.9°C with low ambient accessories) MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 1 2 4 A N S 0 3 6 0 0 0 A Voltage Series Product Family Tier SEER Variations N = 208/230-1 S = Capacity 0 = Not 0 = Not 0 —Not A 1 — AC 2 = Preferred 4 = 14 SEER S = Side Discharge P = 208/230-3 Standard Defined Defined Defined Original E = 460-3 Series Nron. ..ill CERTIFIEDT. C UL US Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program For verification of certification for individual products, go to www.ahridirectory.org. PHYSICAL DATA UNIT SIZE — SERIES (VOLTAGE) 18—A (N) 24—A (N) 30—A (N) 36—A (N, P, E) 48—A (N, P, E) 60—A (N, P, E) COMPRESSOR TYPE Scroll REFRIGERANT Puron® (R-410A) Charge Ib (kg) 6.40 (2.90) 6.50 (2.95) 8.60 (3.90) 8.90 (4.04) 9.00 (4.08) 10.60 (4.81) COND FAN Propeller Type, Direct Drive Air Discharge Horizontal Air Oty (CFM) 1285 1285 1900 2615 2615 2785 Motor HP 1/12 1/12 1/10 1/4 1/4 1/4 Motor RPM 800 800 800 800 800 800 COND COIL Face Area (Sq ft) 7.3 7.3 12.1 12.1 12.1 14.1 Fins per In. 20 20 20 20 20 20 Rows 2 2 2 2 2 2 Circuits 3 3 3 3 3 4 VALVE CONNECT. (In. ID) Vapor 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 REFRIGERANT TUBES* (In. OD) Rated Vapor* 5/8 3/4 3/4 7/8 7/8 1 1 /8 Max Liquid Linet 3/8 * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. t See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. 2 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengthst for Cooling Only Systems with Purono Refrigerant: The maximum allowable length ol'a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. Sce 'l'ablc below for liquid line sizing and maximum lengths Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit Liquid AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit BELOW Indoor Size Liquid Line Line Vertical Separation ft (m) Connection Diam. 0-5 6-10 11-20 21-30 31-40 41-50 51-60 61-70 71-80 w/TXV (0-1.5) (1.8-3.0) (3.4-6.1) (6.4-9.1) (9.4-12.2) (12.5-15.2) (15.5-18.3) (18.6-21.3) (21.6-24.4) 018 1/4 150 150 125 100 100 75 -- -- -- AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 225* 150 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 024 1/4 75 75 75 50 50 -- -- -- -- AC with 3/8 5/16 250* 250* 250* 250* 250* 225* 175 125 100 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 030 1/4 30 -- -- -- — AC with 3/8 5/16 175 225* 200 175 125 100 75 -- -- Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 250* 036 5/16 175 150 150 100 100 100 75 -- -- AC with 3/8 Puron 3//8 250* 250* 250* 250* 250* 250* 250* 250* 250* 048 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 230 160 -- Puron 060 AC with 3/8 3/8 250* 250* 250* 225* 190 150 110 -- Puron * Maximum actual length not to exceed 200 ft (61 m) t Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Liquid AC with Puron Refrigerant Maximum Total Equivalent Lengtht: Outdoor unit ABOVE Indoor Size Liquid Line Line Vertical Separation ft (m) Connection Diam. 25 26-50 51-75 76-100 101-125 126-150 151-175 176-200 w/TXV (7.6) (7.9-15.2) (15.5-22.9) (23.2-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) 018 1/4 175 250* 250* 250* 250* 250* 250* 250* AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 024 1/4 100 125 175 200 225* 250* 250* 250* AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 030 1/4 30 -- -- -- AC with 3/8 5/16 250* 250* 250* 250* 250* 250* 250* 250* Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 036 5/16 225* 250* 250* 250* 250* 250* 250* 250* AC with 3/8 Puron 3/8 250* 250* 250* 250* 250* 250* 250* 250* 048 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* Puron 060 AC with 3/8 3/8 250* 250* 250* 250* 250* 250* 250* 250* Puron * Maximum actual length not to exceed 200 ft (61 m) t Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. -- = outside acceptable range 3 REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) Units are factory charged for 15 ft (4.6 m) of 3/8" liquid line. The factory charge for 3/8" lineset 9 oz (266.16 g). or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft x total length) — (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of line set using existing 1/4" liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) — (9 oz) = (-4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16" liquid line. What is the charge adjustment? Formula: (40 oz/ft. x 45ft) — (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system LONG LINE APPLICATIONS When using other length An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. AC WITH PURON® REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor 1/4 No accessories needed within allowed lengths No accessories needed within allowed lengths 175 (53.3) 5/16 120 (36.6) 50 (15.2) vertical or 120 (36.6) total 120 (36.6) 3/8 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) Note: See Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered vertical separation is 200 ft. (60.96 m) when outdoor unit is "Long line" when the total equivalent tubing length exceeds 80 abovc indoor unit, and up to 80 ft. (24.38 m) when the outdoor ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical unit is below the indoor unit. Refer to Accessory Usage Guideline separation between indoor and outdoor units. These applications below for required accessories. See Longline Application require additional accessories and system modifications for Guideline for required piping and system modifications. Also, reliable system operation. The maximum allowable total refer to the table below for the vapor tube diameters based on the equivalent length is up to 250 ft. (76.2 m). The maximum total length to minimize the cooling capacity loss. Vapor Line Sizing and Cooling Capacity Losses — Puron® Refrigerant 1—Stage Air Conditioner Applications Unit Maximum Vapor Line Cooling Capacity Loss (%) Nominal Liquid Line Diameters is ete rs Total Equivalent Line Length ft. (m) Size (fiDiameters 26-50 51-80 81-100 101-125 126-150 151-175 176-200 201-225 226-250 (in. OD) (7.9-15.2) (15.5-24.4) (24.7-30.5) (30.8-38.1) (38.4-45.7) (46.0-53.3) (53.6-61.0) (61.3-68.6) (68.9-76.2) 018 1/2 1 2 3 I� 6 7 8 r 9 1 Stage 3/8 5/8 0 1 1 IN 1 2 2 2' 3 AC with Puron 3/4 0 0 0 0 1 1 1 1 Mill 024 5/8 0 1 2 0 2 3 3 4 5 1 Stage 3/8 3/4 0 0 1 1 1 1 1 2 2 AC with Puron 7/8 0 0 0 0 0 1 1 1 1 030 5/8 1 2 3 3 4 5 6 7 8 1 Stage 3/8 3/4 0 0 1 1 1 2 2 2 3 AC with Puron 7/8 0 0 0 0 1 1 1 1 1 036 5/8 1 2 4 5 6 8 9 10 12 1 Stage 3/8 3/4 0 1 1 2 2 3 3 4 4 AC with Puron 7/8 0 0 0 1 1 1 1 2 2 048 3/4 0 1 2 3 4 5 5 6 7 1 Stage 3/8 7/8 0 0 1 1 2 2 2 3 3 AC with Puron 11/8 0 0 0 0 0 0 0 1 1 060 3/4 1 2 4 5 6 7 9 10 11 1 Stage AC with 3/8 7/8 0 1 2 2 3 4 4 5 5 Puron 11/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. 4 ACCESSORIES Unit Size (Voltage/Series) KIT NUMBER KIT NAME 018 024 030 036 036 036 048 048 048 060 060 060 (30) (30) (30) (30) (50) (60) (30) (50) (60) (30) (50) (60) KAACH1401AAA Crankcase Heater X X X X X KAACH1201AAA Crankcase Heater X X X X KAACH1501AAA Crankcase Heater X KAACH1901AAA Crankcase Heater X X KSAFT0101AAA Evaporator Freeze Stat X X X X X X X X X X X X KAATD0101TDR Time Delay Relay X X X X X X X X X X X X KAAWS0101AAA Winter Start Kit X X X X X X X X X X X X KSALA0801AAA MotorMasters 230v X X X X X X X X X KSALA0901AAA MotorMasters460v X X X 53DS-900---087 Wind Baffle X X 53DS-900---071 Wind Baffle X X X X X X X 53DS-900---088 Wind Baffle X X X 53DS-900---075 Stacking Kit X X 53DS-900---076 Stacking Kit X X X X X X X X X X 53DS-900---077 Wall Mounting Kit X X 53DS-900---078 Wall Mounting Kit X X X X X X X X X X KAALP0401 PUR Low Pressure Switch Kit X X X X X X X X X X X X KSASH2301COP Sound Blanket Kit X X X X X X KSASH2401COP Sound Blanket Kit X X X X X X KAALS0201 LLS Solenoid Valve Kit X X X X X X X X X X X X KSAHS1501AAA Capacitor Relay Start X X X X X X Assist X = Accessory ACCESSORY THERMOSTATS PART NUMBER DESCRIPTION T6-WEM01 HousewiseT" Wi-Fi@ thermostat T6-PRH01-A Programmable Relative Humidity Thermostat T6-PAC01 Programmable Thermostat T6-NRH01 Non -Programmable Relative Humidity Thermostat T6-NAC01 Non -Programmable Thermostat T2-WHS01 Wi-Fi@ Thermostat T2-PAC01 Programmable Thermostat T2-NAC01 Non -Programmable Thermostat T2SNAC01 Non -Programmable Standard Screen Thermostat THERMOSTAT ACCESSORIES PART NUMBER DESCRIPTION THERMOSTATS USED WITH T6-EXP EXPO Card T6-Pxx, T6-Nxx TSTATXXSEN01-B Outdoor Air Temperature Sensor T6-Pxx, T6-Nxx TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) - 10 pack All Bryant@ branded thermostats TX-MBP01 Medium Decorative Backplate T2-Nxx TX-LBP01 Large Decorative Backplate T6-Pxx, T6-Nxx, T2-Pxx ACCESSORY USAGE GUIDELINE Accessory Ball Bearing Fan Motor Compressor Start Assist Capacitor and Relay Crankcase Heater Evaporator Freeze Thermostat Liquid Line Solenoid Valve MotorMaster@ Controller REQUIRED FOR LOW —AMBIENT COOLING APPLICATIONS (Below 55°F / 12.8°C) Standard Yes Yes Yes No Yes REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 ft. / 24.38 m) Standard Yes Yes No See Long —Line Application Guideline No REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) Standard No No No No No * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split —System Longline Application Guideline. Accessory Description and Usage (Listed Alphabetically) 1. Ball —Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when using MotorMaster° 2. Compressor Start Assist — Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single—phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 4. Evaporator Freeze Thermostat An SPST temperature —actuated switch that stops unit operation when evaporator reaches freeze—up conditions. Usage Guideline: Required when low ambient kit has been added. 5. Low Pressure Switch Kit Optional added compressor protection against loss of refrigerant. It cuts out the system at 50 PSI and allows operation again at 95 PSI. Used for commercial or "harsh" environment applications for extra protection. Not required for Low —Ambient Cooling application. 6. MotorMaster Low —Ambient Controller A fan —speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated condensing temperatures down to —20°F (-28.9°C), it maintains condensing temperature at 100°F +/— 10°F (37.8°C +/— 6 °C) Usage Guideline: A MotorMaster Low —Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55°F (12.8°C). Suggested for all commercial applications. 7. Winter Start Kit The device is designed to alleviate nuisance opening of the low—pressure switch by bypassing it for the first 3 minutes of operation. A Winter Start control must be used where low evaporator temperatures, or nuisance tripping of low—pressure switch may be encountered. It is not required for low ambient cooling application unless a low—pressure switch KAALP0401PUR is added. 8. Time Relay Delay Optional Accessory for systems that do not have an integral blower time delay. ELECTRICAL DATA UNIT SIZE - OPER VOLTS* SERIES V/PH (VOLTAGE) MAX MIN LRA 018-A (N) 56.3 024-A (N) 62.9 030-A (N) 208/230/1 253 197 73.0 036-A (N) 77.0 048-A (N) 124.0 060-A (N) 152.5 036-A (P) 71.0 048-A (P) 208/230/3 253 197 83.1 060-A (P) 110.0 036-A (E) 38.0 048-A (E) 460/3 506 414 41.0 060-A (E) 52.0 LEGEND: FLA - Full Load Amps HACR - Heating, Air Conditioning, Refrigeration LRA - Locked Rotor Amps NEC - National Electrical Code RLA - Rated Load Amps (compressor) * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time -Delay fuse. Complies with 2007 requirements of ASHRAE Standards 90.1 COMPR FAN MAX FUSE** or MCA RLA FLA CKT BRK AMPS 9.0 0.50 11.8 20 10.9 0.50 14.1 25 14.1 0.70 18.3 30 14.1 1.20 18.8 30 18.5 1.20 24.3 40 23.7 1.45 31.1 50 9.0 1.20 12.5 20 13.7 1.20 18.3 30 15.9 1.45 21.4 35 5.6 0.60 7.6 15 6.2 0.70 8.5 15 7.1 0.80 9.7 15 A -WEIGHTED SOUND POWER (dBA) Standard Unit Size Rating Typical Octave Band Spectrum (dBA, without tone adjustment) (dBA) 125 250 500 18 69 50.5 57.0 59.5 24 66 50.5 58.5 60.5 30 68 55.5 59.5 61.5 36 71 59.5 59.5 62.0 48 70 57.5 59.5 64.0 60 73 60.0 61.5 64.5 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI) 1000 2000 4000 8000 64.5 60.5 53.5 43.0 59.5 56.5 51.0 41.5 63.5 60.0 58.0 49.5 65.5 63.5 62.0 55.0 66.0 63.0 60.5 54.5 67.0 66.0 65.5 58.0 A -WEIGHTED SOUND POWER (dBA) WITH ACCESSORY SOUND SHIELD Standard Typical Octave Band Spectrum (dBA, without tone adjustment) Unit Size Rating (dBA) 125 250 500 1000 2000 4000 8000 18 68 52.5 58.0 58.5 64.5 59.5 52.5 42.5 24 65 54.5 57.5 59.5 59.0 56.0 50.5 40.5 30 68 55.0 60.0 61.5 62.5 60.0 58.0 49.5 36 71 59.5 59.5 62.5 65.0 63.0 61.5 55.0 48 70 57.5 59.5 63.0 65.0 62.5 60.0 54.0 60 73 61.0 62.0 64.0 67.0 65.5 65.5 57.5 NOTES: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI). Accessory sound shield will not accommodate unit sizes 18 and 24. CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE) UNIT SIZE -SERIES REQUIRED SUBCOOLING °F (°C) 18 12 (6.7) 24 12 (6.7) 30 12 (6.7) 36 8(4.4) 48 12 (6.7) 60 10(5.6) 7 00 DIMENSIONS — ENGLISH ®m 0000©00©0©0©©0�� o o M '9 X = YES O (9 O M 0 = NO � N O �o O N N • TIM MINIMUM UNIT SIZE MOUNTING PAD DIMENSIONS 18,24 23" X 42" 30,36,48,60 24" X 50" CLEARANCE REQUIREMENTS: SINGLE UNIT APPLICATIONS: WITH COIL FACING WALL: ALLOW 6 IN. MINIMUM CLEARANCE ON COIL SIDE AND COIL END AND 20 IN. MINIMUM CLEARANCE ON FAN SIDE. WITH FAN FACING WALL: ALLOW 8 IN. MINIMUM CLEARANCE ON FAN SIDE AND 6 IN. ON COIL END AND 20 IN. MINIMUM CLEARANCE ON COIL SIDE. MULTI - UNIT APPLICATIONS: ALLOW 24 IN. MINIMUM CLEARANCE BETWEEN FAN AND COIL SIDES OF MULTIPLE UNITS. ARRANGE UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOTHER.WHEN TWO UNITS ARE INSTALLED END TO END WITH THE COIL ENDS FACING EACH OTHER ALLOW 12 IN. MINIMUM CLEARANCE BETWEEN UNITS. COMPRESSOR END SERVICE CLEARANCE: ALLOW 24 IN. MINIMUM CLEARANCE ON COMPRESSOR END WHEN UNITS ARE STACKED OR THERE IS LESS THAN 40 IN. OF CLEARANCE ABOVE THE TOP OF THE UNIT. IF THERE IS 40 IN. CLEARANCE ABOVE UNIT AND THE TOP PANEL IS ACCESSIBLE FOR REMOVAL ALLOW 8 IN. MINIMUM CLEARANCE ON COMPRESSOR END FOR SERVICE. IMPORTANT: WHEN INSTALLING SINGLE OR MULTIPLE UNITS IN AN ALCOVE, ROOF WELL, OR PARTIALLY ENCLOSED AREA, ENSURE THERE IS ADEQUATE VENTILATION TO PREVENT RECIRCULATION OF DISCHARGE AIR. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING 112" MODE IS WE, MAX. 125°F. 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY 4 3/16" 5. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. FIELD CONTROL SUPPL WIRE ENTRY 7/8" HOLE W/GROMMET M VAPOR LINE CONN. FEMALE SWEAT CONN. /8" LIQUID LINE TALE SWEAT CONN. 2 IONS fi7f[� IELD POWER SUPPLY CONN. 0LE SIZES PROVIDED: 0 7/8" HOLE WITH 0 1 1/8" KNOCKOUT AND 0 1 3/8" KNOCKOUT R DIMENSIONS - SI 0 - 0000©00©0©0©� OPERATING) D SHIPPING C�) X = YES M M �,:� 0 = NO Oc. tb N co O 0 N N MINIMUM UNIT SIZE MOUNTING PAD DIMENSIONS 18,24 584.2 X 1066.8 30,36,48,60 609.6 X 1270.0 1. CLEARANCE REQUIREMENTS: SINGLE UNIT APPLICATIONS: WITH COIL FACING WALL: ALLOW 152.4 mm MINIMUM CLEARANCE E ON COIL SIDE AND COIL END AND 504 mm MINIMUM CLEARANCE ON FAN SIDE. WITH FAN FACING WALL: ALLOW 203.2 mm MINIMUM CLEARANCE ON FAN SIDE AND 152.4 mm ON COIL END AND 504.0 mm MINIMUM CLEARANCE ON COIL SIDE. MULTI -UNIT APPLICATIONS: ALLOW 609.6 mm MINIMUM CLEARANCE BETWEEN FAN AND COIL SIDES OF MULTIPLE UNITS. ARRANGE UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOTHER.WHEN TWO UNITS ARE INSTALLED END TO END WITH THE COIL ENDS FACING EACH OTHER ALLOW 304.8 mm MINIMUM CLEARANCE BETWEEN UNITS. COMPRESSOR END SERVICE CLEARANCE: ALLOW 609.6 mm MINIMUM CLEARANCE ON COMPRESSOR END WHEN UNITS ARE STACKED OR THERE IS LESS THAN 1016 mm OF CLEARANCE ABOVE THE TOP OF THE UNIT. IF THERE IS 1016 mm CLEARANCE ABOVE UNIT AND THE TOP PANEL IS ACCESSIBLE FOR REMOVAL ALLOW 203.2 mm MINIMUM CLEARANCE ON COMPRESSOR END FOR SERVICE. IMPORTANT: WHEN INSTALLING SINGLE OR MULTIPLE UNITS IN AN ALCOVE, ROOF WELL, OR PARTIALLY ENCLOSED AREA, ENSURE THERE IS ADEQUATE VENTILATION TO PREVENT RECIRCULATION OF DISCHARGE AIR. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING 3.6 MODE IS 12.8°C, MAX. 51.7°C. 3. SERIES DESIGNATION IS THE 14TH POSITION OF THE UNIT MODEL NUMBER. 4. CENTER OF GRAVITY 106.3 5. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED. FIELD CONTROL SUPPL WIRE ENTRY 22.22 HOLE W/GROMME M VAPOR LINE CONN. FEMALE SWEAT CONN. 9.53 LIQUID LINE .MALE SWEAT CONN. FIELD POWER SUPPLY CONN. HOLE SIZES PROVIDED: iR 0 22.23 HOLE WITH D 0 28.58 KNOCKOUT AND IONS 36.2 0 34.93 KNOCKOUT TESTED AHRI COMBINATION RATINGS* NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectomorg Additional ratings and system combinations can be accessed via the Bryant database at: www.MyBryantRatings.com For performance data at specific application &/or design conditions with various indoor unit combinations, the equipment performance calculator can be accessed at : http://rpmobbU.wrightsoft.com/ .wrightsoft.com/ Outdoor Model Number — Series (voltage) Indoor Coil Model Number Furnace Model Number Capacity EER SEER 124ANS018—A (N) CNPV*3014AL*+TDR 18,000 12.2 14 124ANS024—A (N) CNPV*3117AL*+TDR 24,000 12.2 14 124ANS030—A (N) CNPV*3117AL*+TDR 29,600 12.2 14 124ANS036—A (N,P,E) CNPV*3717AL*+TDR 35,400 12.2 14 124ANSO48—A (N,P,E) CNPV*6024AL*+TDR 45,000 11.7 14 124ANS060—A (N,P,E) CNPV*6124AL*+TDR 57,000 11.7 14 EER — Energy Efficiency Ratio SEER— Seasonal Energy Efficiency Ratio TXV — Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. 10 DETAILED COOLING CAPACITIES EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES °F (°C) 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) EWB Capacity MBtuh P y Total Capacity MBtuh P y Total Capacity MBtuh P ri Total Capacity MBtuh P ri Total Capacity MBtuh P y Total Capacity MBtuh P y Total CFM °F Sys Sys Sys Sys Sys Sys (°C) Total Sens# KW** Total Sens# KW** Total Sens$ KW** Total Sens$ KW** Total Sens# KW** Total Sens# KW** 72 (22.2) 21.49 10.92 1.18 20.55 10.57 1.31 Outdoor 19.56 Section With 10.21 CNPV*3014AL* 1.45 Indoor 18.50 Section 9.83 1.61 17.36 9.43 1.79 16.12 9.00 2.00 67 (19.4) 19.43 13.31 1.18 18.58 12.96 1.31 17.67 12.60 1.45 16.71 12.22 1.61 15.68 11.82 1.79 14.57 11.39 2.00 525 63 (17.2) 17.96 12.78 1.18 17.15 12.43 1.31 16.31 12.06 1.45 15.43 11.69 1.61 14.48 11.29 1.79 13.46 10.86 2.00 62 (16.7) 17.68 15.68 1.18 16.91 15.33 1.31 16.11 14.96 1.45 15.28 14.56 1.61 14.48 14.48 1.79 13.65 13.65 2.00 57 (13.9) 17.17 17.17 1.18 16.55 16.55 1.31 15.91 15.91 1.45 15.21 15.21 1.61 14.46 14.46 1.79 13.63 13.63 2.00 72 (22.2) 21.93 11.50 1.21 20.94 11.14 1.34 19.90 10.77 1.48 18.79 10.38 1.64 17.61 9.97 1.82 16.32 9.53 2.03 67 (19.4) 19.84 14.22 1.21 18.94 13.87 1.34 18.00 13.50 1.48 17.00 13.11 1.63 15.93 12.70 1.82 14.78 12.26 2.03 600 63 (17.2) 18.34 13.63 1.21 17.51 13.27 1.33 16.63 12.90 1.47 15.70 12.51 1.63 14.72 12.10 1.82 13.65 11.66 2.03 62 (16.7) 18.14 16.91 1.21 17.36 16.53 1.33 16.61 16.61 1.47 15.86 15.86 1.63 15.05 15.05 1.82 14.15 14.15 2.03 57 (13.9) 17.95 17.95 1.21 17.29 17.29 1.33 16.59 16.59 1.47 15.84 15.84 1.63 15.02 15.02 1.82 14.13 14.13 2.03 72 (22.2) 22.25 12.05 1.24 21.22 11.69 1.36 20.15 11.31 1.50 19.00 10.91 1.66 17.78 10.50 1.85 16.46 10.05 2.06 67 (19.4) 20.15 15.11 1.24 19.22 14.74 1.36 18.25 14.37 1.50 17.22 13.97 1.66 16.12 13.55 1.85 14.94 13.09 2.06 675 63 (17.2) 18.64 14.45 1.24 17.77 14.08 1.36 16.86 13.70 1.50 15.91 13.30 1.66 14.90 12.88 1.84 13.81 12.42 2.05 62 (16.7) 18.63 18.63 1.24 17.92 17.92 1.36 17.18 17.18 1.50 16.38 16.38 1.66 15.51 15.51 1.84 14.56 14.56 2.06 57 (13.9) 18.60 18.60 1.24 17.89 17.89 1.36 17.15 17.15 1.50 16.36 16.36 1.66 15.49 15.49 1.84 14.55 14.55 2.06 CONDENSER ENTERING AIR TEMPERATURES °F (°C) EVAPORATOR AIR 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) EWB Capacity MBtuh P y Total Capacity MBtuh P y Total Capacity MBtuh P y Total Capacity MBtuh P y Total Capacity MBtuh P y Total Capacity MBtuh P y Total CFM °F Sys Sys Sys Sys Sys Sys (°C) Total Sens# KW** Total Sens# KW** Total Sens# KW** Total Sens# KW** Total Sens# KW** Total Sens# KW** 72 (22.2) 28.62 14.23 1.58 27.33 13.77 124ANS024-A 1.75 Outdoor 25.95 Section With 13.30 CNPV*3117AL* 1.94 Indoor 24.48 Section 12.80 2.15 22.90 12.26 2.40 21.21 11.70 2.67 67 (19.4) 26.06 17.53 1.57 24.88 17.08 1.74 23.63 16.60 1.93 22.30 16.09 2.14 20.87 15.56 2.39 19.33 14.99 2.67 700 63 (17.2) 24.20 16.87 1.57 23.11 16.41 1.74 21.96 15.94 1.92 20.73 15.44 2.14 19.41 14.91 2.38 17.99 14.34 2.66 62 (16.7) 23.80 20.79 1.57 22.74 20.32 1.73 21.65 19.83 1.92 20.58 20.58 2.14 19.51 19.51 2.38 18.33 18.33 2.66 57 (13.9) 23.29 23.29 1.57 22.44 22.44 1.73 21.53 21.53 1.92 20.55 20.55 2.14 19.48 19.48 2.38 18.31 18.31 2.66 72 (22.2) 29.11 14.99 1.62 27.76 14.53 1.79 26.33 14.04 1.98 24.80 13.53 2.19 23.16 12.99 2.43 21.41 12.42 2.71 67 (19.4) 26.53 18.75 1.61 25.30 18.29 1.78 24.00 17.80 1.97 22.61 17.28 2.18 21.13 16.74 2.43 19.54 16.16 2.70 800 63 (17.2) 24.68 18.01 1.61 23.53 17.54 1.77 22.33 17.06 1.96 21.05 16.55 2.18 19.67 16.00 2.42 18.21 15.42 2.70 62 (16.7) 24.39 22.42 1.61 23.40 23.40 1.77 22.42 22.42 1.96 21.36 21.36 2.18 20.20 20.20 2.42 18.94 18.94 2.70 57 (13.9) 24.28 24.28 1.61 23.36 23.36 1.77 22.39 22.39 1.96 21.32 21.32 2.18 20.17 20.17 2.42 18.91 18.91 2.70 72 (22.2) 29.46 15.72 1.66 28.07 15.25 1.83 26.59 14.76 2.01 25.01 14.24 2.23 23.33 13.69 2.47 21.53 13.11 2.75 67 (19.4) 26.88 19.93 1.65 25.61 19.46 1.82 24.27 18.96 2.01 22.84 18.43 2.22 21.32 17.87 2.46 19.70 17.27 2.74 900 63 (17.2) 25.04 19.11 1.65 23.85 18.63 1.81 22.60 18.14 2.00 21.28 17.61 2.21 19.87 17.05 2.46 18.38 16.43 2.74 62 (16.7) 25.15 25.15 1.65 24.16 24.16 1.81 23.11 23.11 2.00 21.98 21.98 2.22 20.75 20.75 2.46 19.42 19.42 2.74 57 (13.9) 25.11 25.11 1.65 24.13 24.13 1.81 23.08 23.08 2.00 21.95 21.95 2.22 20.73 20.73 2.46 19.39 19.39 2.74 See notes on pg. 13 N DETAILED COOLING CAPACITIES (CONT.) CONDENSER ENTERING AIR TEMPERATURES -F (-C) Evaporator Air 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) Total Total Total Total Total Total Capacity MBtuht System Capacity MBtuht System Capacity MBtuht System Capacity MBtuht System Capacity MBtuht System Capacity MBtuht System CFM EWB KW** KW** KW** KW** KW** KW** .F (-C) Total Total Total Total Total Total Total Sens# System Total Sens# System Total Sens# System Total Sens# System Total Sens# System Total Sens# System KW** KW** KW** KW** KW** KW** 72 (22.2) 35.20 16.84 1.95 33.62 16.29 124ANS030-A 2.18 Outdoor 31.97 Section 15.73 With CNPV*3117AL* 2.43 Indoor 30.18 Section 15.13 2.70 28.24 14.48 3.02 26.13 13.79 3.38 67 (19.4) 31.99 20.62 1.92 30.56 20.08 2.15 29.06 19.51 2.40 27.44 18.91 2.68 25.67 18.26 3.00 23.75 17.57 3.36 875 63 (17.2) 29.66 19.84 1.90 28.34 19.30 2.13 26.95 18.74 2.37 25.45 18.13 2.66 23.80 17.48 2.98 22.02 16.78 3.35 62 (16.7) 29.18 24.36 1.90 27.92 23.82 2.12 26.58 23.24 2.37 25.18 24.97 2.65 23.81 23.81 2.98 22.34 22.34 3.35 57 (13.9) 28.38 28.38 1.89 27.37 27.37 2.12 26.28 26.28 2.37 25.09 25.09 2.65 23.77 23.77 2.98 22.31 22.31 3.35 72 (22.2) 35.90 17.73 1.98 34.26 17.17 2.21 32.52 16.59 2.46 30.66 15.98 2.74 28.65 15.32 3.05 26.46 14.62 3.41 67 (19.4) 32.65 22.03 1.95 31.17 21.48 2.18 29.60 20.90 2.43 27.91 20.28 2.71 26.08 19.62 3.03 24.10 18.91 3.39 1000 63 (17.2) 30.30 21.15 1.93 28.93 20.60 2.16 27.48 20.02 2.40 25.91 19.41 2.69 24.21 18.74 3.01 22.36 18.02 3.37 62 (16.7) 29.94 26.26 1.93 28.66 25.66 2.15 27.43 27.43 2.41 26.15 26.15 2.69 24.73 24.73 3.01 23.17 23.17 3.38 57 (13.9) 29.65 29.65 1.93 28.56 28.56 2.15 27.39 27.39 2.40 26.11 26.11 2.69 24.70 24.70 3.01 23.14 23.14 3.38 72 (22.2) 36.44 18.57 2.01 34.73 18.00 2.24 32.94 17.41 2.49 31.02 16.79 2.77 28.94 16.12 3.08 26.71 15.41 3.43 67 (19.4) 33.18 23.38 1.98 31.64 22.82 2.21 30.01 22.23 2.46 28.28 21.60 2.74 26.40 20.92 3.05 24.38 20.18 3.41 1125 63 (17.2) 30.81 22.41 1.96 29.38 21.85 2.19 27.89 21.26 2.43 26.28 20.63 2.72 24.53 19.94 3.04 22.65 19.20 3.40 62 (16.7) 30.76 30.76 1.96 29.59 29.59 2.19 28.34 28.34 2.44 26.99 26.99 2.72 25.49 25.49 3.05 23.84 23.84 3.41 57 (13.9) 30.72 30.72 1.96 29.55 29.55 2.19 28.31 28.31 2.44 26.95 26.95 2.72 25.45 25.45 3.04 23.81 23.81 3.41 CONDENSER ENTERING AIR TEMPERATURES °F ('C) EVAPORATOR AIR 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) EWB Ca acit MBtuh p y Total Capacity MBtuh p y Total Capacity MBtuh P Total Capacity MBtuh P Total Capacity Ca acit MBtuh Total CapacityMBtuh Total CFM 'F Sys Sys Sys Sys Sys Sys ('C) Total Sens# KW** Total Sens# KW** Total Sens$ KW** Total Sens$ KW** Total Sens# KW** Total Sens# KW** r Outdoor 72 (22.2) 42.58 22.26 2.36 40.51 21.51 2.60 38.30 20.71 2.87 35.94 19.87 3.16 33.37 18.97 3.50 30.62 18.01 3.88 67 (19.4) 38.73 27.46 2.34 36.87 26.71 2.58 34.88 25.92 2.84 32.74 25.08 3.14 30.43 24.18 3.48 27.97 23.23 3.86 1050 63 (17.2) 35.96 26.41 2.32 34.24 25.67 2.56 32.40 24.88 2.82 30.43 24.04 3.12 28.31 23.15 3.46 26.03 22.20 3.85 62 (16.7) 35.38 32.60 2.32 33.73 31.84 2.56 32.01 31.81 2.82 30.38 30.38 3.12 28.63 28.63 3.46 26.73 26.73 3.85 57 (13.9) 34.71 34.71 2.31 33.37 33.37 2.55 31.92 31.92 2.82 30.34 30.34 3.12 28.59 28.59 3.46 26.70 26.70 3.85 72 (22.2) 43.29 23.46 2.42 41.13 22.69 2.66 38.84 21.88 2.93 36.37 21.02 3.22 33.71 20.10 3.56 30.85 19.13 3.94 67 (19.4) 39.43 29.38 2.40 37.47 28.61 2.64 35.40 27.80 2.90 33.18 26.94 3.20 30.79 26.02 3.53 28.26 25.05 3.92 1200 63 (17.2) 36.64 28.20 2.38 34.83 27.43 2.62 32.92 26.62 2.88 30.87 25.77 3.18 28.67 24.85 3.52 26.33 23.88 3.91 62 (16.7) 36.27 36.05 2.38 34.77 34.77 2.62 33.20 33.20 2.89 31.50 31.50 3.19 29.61 29.61 3.53 27.57 27.57 3.92 57 (13.9) 36.17 36.17 2.38 34.71 34.71 2.62 33.15 33.15 2.89 31.45 31.45 3.19 29.57 29.57 3.53 27.54 27.54 3.91 72 (22.2) 43.81 24.60 2.48 41.58 23.82 2.72 39.20 23.00 2.99 36.66 22.13 3.28 33.92 21.20 3.62 31.04 20.23 4.00 67 (19.4) 39.93 31.22 2.46 37.92 30.44 2.70 35.78 29.61 2.96 33.50 28.73 3.26 31.06 27.78 3.59 28.49 26.76 3.98 1350 63 (17.2) 37.14 29.91 2.44 35.28 29.13 2.68 33.30 28.30 2.94 31.20 27.42 3.24 28.94 26.47 3.58 26.58 25.43 3.97 62 (16.7) 37.43 37.43 2.44 35.87 35.87 2.68 34.21 34.21 2.95 32.39 32.39 3.25 30.39 30.39 3.59 28.23 28.23 3.98 57 (13.9) 37.38 37.38 2.44 35.83 35.83 2.68 34.16 34.16 2.95 32.35 32.35 3.25 30.36 30.36 3.59 28.20 28.20 3.98 See notes on pg. 13 DETAILED COOLING CAPACITIES (CONT.) EVAPORATOR AIR 75 (23.9) 85 (29.4) Capacity MBtuh Total Capacity MBtuh Total CFM EWB P y Sys P y Sys °F (°C) Total Sens# KW- Total Sens# KW** CONDENSER ENTERING AIR TEMPERATURES °F (°C) 95 (35) 105 (40.6) Capacity MBtuh Total Capacity MBtuh P y Sys P y Total Sens# KW** Total Sens# •CNPV*6024AL* Indoor Section Total Sys KW** 115 (46.1) Capacity MBtuh P y Total Sens# Total Sys KW-* 125 (51.7) Capacity MBtuh P y Total Sens# Total Sys KW** 72 (22.2) 54.32 28.47 3.22 51.89 27.57 3.53 49.29 26.62 3.88 46.43 25.59 4.29 43.30 24.47 4.76 39.89 23.27 5.30 67 (19.4) 49.54 35.14 3.19 47.35 34.25 3.49 45.00 33.30 3.85 42.43 32.28 4.25 39.60 31.16 4.72 36.51 29.95 5.26 1400 63 (17.2) 46.06 33.82 3.16 44.05 32.94 3.47 41.89 32.00 3.82 39.52 30.98 4.22 36.90 29.87 4.69 34.04 28.66 5.23 62 (16.7) 45.44 41.73 3.15 43.53 40.82 3.46 41.48 39.82 3.81 39.37 39.37 4.22 37.22 37.22 4.70 34.80 34.80 5.24 57 (13.9) 44.54 44.54 3.15 42.97 42.97 3.46 41.24 41.24 3.81 39.32 39.32 4.22 37.17 37.17 4.70 34.76 34.76 5.24 72 (22.2) 55.17 29.90 3.30 52.64 28.99 3.61 49.92 28.01 3.96 46.96 26.96 4.37 43.72 25.83 4.84 40.19 24.61 5.38 67 (19.4) 50.36 37.46 3.27 48.09 36.55 3.57 45.64 35.59 3.93 42.97 34.53 4.34 40.05 33.39 4.81 36.86 32.13 5.34 1600 63 (17.2) 46.86 35.98 3.24 44.77 35.09 3.55 42.51 34.12 3.90 40.05 33.08 4.31 37.35 31.93 4.77 34.40 30.67 5.31 62 (16.7) 46.51 44.79 3.24 44.64 44.64 3.55 42.79 42.79 3.90 40.73 40.73 4.31 38.42 38.42 4.79 35.83 35.83 5.33 57 (13.9) 46.30 46.30 3.24 44.60 44.60 3.55 42.73 42.73 3.90 40.67 40.67 4.31 38.37 38.37 4.79 35.79 35.79 5.33 72 (22.2) 55.79 31.25 3.38 53.16 30.32 3.69 50.36 29.34 4.04 47.31 28.27 4.45 43.97 27.12 4.92 40.37 25.89 5.46 67 (19.4) 50.98 39.68 3.35 48.62 38.75 3.65 46.10 37.76 4.01 43.37 36.69 4.42 40.37 35.50 4.89 37.14 34.18 5.42 1800 63 (17.2) 47.47 38.04 3.32 45.30 37.12 3.63 42.98 36.13 3.98 40.45 35.06 4.39 37.69 33.87 4.86 34.70 32.54 5.39 62 (16.7) 47.80 47.80 3.32 45.99 45.99 3.63 44.00 44.00 3.99 41.81 41.81 4.40 39.36 39.36 4.88 36.64 36.64 5.42 57 (13.9) 47.74 47.74 3.32 45.93 45.93 3.63 43.95 43.95 3.99 41.76 41.76 4.40 39.32 39.32 4.87 36.60 36.60 5.41 CONDENSER ENTERING AIR TEMPERATURES °F (°C) EVAPORATOR AIR 75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7) EWB Capacity MBtuh P ri Total Capacity MBtuh P y Total Capacity MBtuh P ri Total Capacity MBtuh P y Total Capacity MBtuh P y Total Capacity P y MBtuh Total CFM °F Sys Sys Sys Sys Sys Sys (°C) Total Sens$ Kyy** Total Sens# KW** Total 0.r Sens# KW** Total Sens# KW** Total Sens# KW** Total Sens# KW** 72 (22.2) 68.86 34.68 4.09 65.73 33.57 4.48 62.37 32.40 4.93 58.68 31.12 5.45 54.65 29.75 6.04 50.21 28.26 6.71 67 (19.4) 62.81 42.85 4.03 60.01 41.76 4.42 57.00 40.60 4.87 53.69 39.34 5.39 50.05 37.96 5.98 46.03 36.46 6.65 1750 63 (17.2) 58.41 41.24 3.99 55.85 40.17 4.38 53.11 39.03 4.82 50.06 37.78 5.34 46.70 36.41 5.93 42.98 34.90 6.59 w 62 (16.7) 57.61 50.93 3.98 55.17 49.82 4.37 52.58 48.59 4.82 49.93 49.93 5.34 47.15 47.15 5.94 44.00 44.00 6.61 57 (13.9) 56.53 56.53 3.97 54.53 54.53 4.37 52.32 52.32 4.82 49.86 49.86 5.34 47.09 47.09 5.94 43.94 43.94 6.61 72 (22.2) 69.94 36.44 4.19 66.66 35.31 4.58 63.14 34.10 5.04 59.32 32.81 5.56 55.14 31.41 6.15 50.56 29.90 6.81 67 (19.4) 63.84 45.70 4.14 60.93 44.59 4.53 57.78 43.40 4.98 54.34 42.10 5.49 50.59 40.69 6.08 46.45 39.14 6.75 2000 63 (17.2) 59.43 43.90 4.09 56.76 42.80 4.48 53.87 41.62 4.93 50.72 40.34 5.44 47.25 38.93 6.03 43.42 37.37 6.70 62 (16.7) 58.98 54.67 4.09 56.66 56.66 4.48 54.28 54.28 4.94 51.61 51.61 5.46 48.63 48.63 6.06 45.27 45.27 6.73 57 (13.9) 58.76 58.76 4.09 56.58 56.58 4.48 54.20 54.20 4.93 51.55 51.55 5.46 48.57 48.57 6.05 45.22 45.22 6.73 72 (22.2) 70.70 38.10 4.29 67.30 36.94 4.68 63.68 35.72 5.14 59.73 34.41 5.66 55.44 32.99 6.25 50.77 31.46 6.91 67 (19.4) 64.61 48.42 4.24 61.59 47.28 4.63 58.35 46.06 5.08 54.82 44.74 5.59 50.98 43.27 6.18 46.79 41.64 6.85 2250 63 (17.2) 60.18 46.42 4.19 57.41 45.29 4.58 54.45 44.09 5.03 51.21 42.77 5.55 47.66 41.31 6.13 43.79 39.65 6.80 62 (16.7) 60.66 60.66 4.20 58.34 58.34 4.59 55.79 55.79 5.05 52.96 52.96 5.57 49.81 49.81 6.17 46.25 46.25 6.84 57 (13.9) 60.58 60.58 4.20 58.27 58.27 4.59 55.72 55.72 5.05 52.90 52.90 5.57 49.75 49.75 6.17 46.20 46.20 6.84 $ Total and sensible capacities are net capacities. Blower motor heat has been subtracted. $ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh (245 kW) per 1000 CFM (480 US) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 US) of indoor coil air per degree above 80°F (27°C). ** System kw is total of indoor and outdoor unit kilowatts. EWB - Entering Wet Bulb NOTES: 1. Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240-2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. 2. When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. CONDENSER ONLY RATINGS SST CONDENSER ENTERING AIR TEMPERATURES °F (°C) °F (°C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) TCG 16.60 15.60 14.70 13.80 12.90 12.00 11.10 10.10 30 (-1.11) SDT 68.50 78.00 87.50 97.00 106.50 116.00 125.40 134.70 KW 0.76 0.87 0.99 1.11 1.25 1.40 1.59 1.80 TCG 18.30 17.20 16.30 15.30 14.30 13.30 12.30 11.20 35 (167) SDT 69.70 79.20 88.70 98.20 107.60 117.00 126.30 135.50 KW 0.76 0.87 0.99 1.11 1.25 1.41 1.59 1.80 TCG 20.00 19.00 17.90 16.90 15.80 14.70 13.60 12.40 40 (4.44) SDT 71.10 80.50 89.90 99.40 108.70 118.00 127.20 136.30 KW 0.77 0.88 0.99 1.11 1.25 1.41 1.59 1.80 TCG 22.00 20.80 19.70 18.50 17.40 16.20 14.90 13.60 45 (7.22) SDT 72.50 81.90 91.30 100.60 109.80 119.00 128.20 137.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80 TCG 24.00 22.80 21.60 20.40 19.10 17.80 16.40 15.00 50 (10.0) SDT 74.00 83.40 92.60 101.90 111.00 120.10 129.20 138.20 KW 0.77 0.88 0.99 1.12 1.26 1.41 1.59 1.80 TCG 26.30 25.00 23.60 22.30 20.90 19.50 18.00 16.40 55 (12.78) SDT 75.60 84.80 94.10 103.20 112.30 121.30 130.30 139.20 KW 0.78 0.88 1.00 1.12 1.26 1.42 1.60 1.80 TCG 21.40 20.20 19.00 17.80 16.60 15.40 14.20 12.90 30 (-1.11) SDT 71.90 81.30 90.70 100.00 109.30 118.50 127.70 136.80 KW 1.01 1.15 1.30 1.46 1.64 1.85 2.09 2.36 TCG 23.50 22.20 20.90 19.60 18.30 17.00 15.60 14.20 35 (167) SDT 73.50 82.80 92.10 101.30 110.50 119.60 128.70 137.70 KW 1.02 1.16 1.30 1.47 1.65 1.86 2.09 2.37 TCG 25.70 24.40 23.00 21.60 20.20 18.70 17.20 15.60 40 (4.44) SDT 75.10 84.30 93.50 102.60 111.80 120.80 129.80 138.80 KW 1.02 1.16 1.31 1.47 1.66 1.86 2.10 2.38 TCG 28.20 26.70 25.20 23.70 22.10 20.50 18.90 17.10 45 (7.22) SDT 76.70 85.90 95.00 104.10 113.10 122.10 131.00 139.80 KW 1.03 1.17 1.32 1.48 1.66 1.87 2.11 2.39 TCG 30.80 29.20 27.50 25.90 24.20 22.40 20.60 18.70 50 (10.0) SDT 78.50 87.50 96.60 105.60 114.60 123.40 132.20 140.90 KW 1.04 1.18 1.32 1.49 1.67 1.88 2.12 2.39 TCG 33.60 31.80 30.10 28.30 26.40 24.50 22.40 20.30 55 (12.78) SDT 80.30 89.30 98.30 107.20 116.10 124.90 133.50 142.00 KW 1.05 1.18 1.33 1.50 1.68 1.89 2.13 2.40 TCG 27.20 25.80 24.40 22.90 21.40 19.70 17.90 16.00 30 (-1.11) SDT 69.90 79.20 88.60 98.00 107.30 116.60 125.80 134.80 KW 1.22 1.39 1.57 1.77 2.00 2.27 2.58 2.94 TCG 30.10 28.50 27.00 25.40 23.70 21.90 20.00 17.90 35 (167) SDT 71.20 80.60 89.90 99.20 108.50 117.70 126.80 135.80 KW 1.22 1.40 1.58 1.78 2.01 2.28 2.58 2.94 TCG 33.10 31.40 29.70 28.00 26.20 24.30 22.20 20.00 40 (4.44) SDT 72.70 82.00 91.20 100.50 109.70 118.90 127.90 136.90 KW 1.23 1.41 1.59 1.80 2.03 2.29 2.59 2.94 TCG 36.50 34.50 32.70 30.80 28.80 26.80 24.50 22.10 45 (7.22) SDT 74.30 83.50 92.70 101.90 111.00 120.10 129.10 137.90 KW 1.25 1.43 1.61 1.82 2.05 2.31 2.60 2.95 TCG 40.00 37.90 35.80 33.80 31.60 29.40 27.00 24.40 50 (10.0) SDT 76.00 85.10 94.20 103.40 112.40 121.40 130.30 139.00 KW 1.27 1.45 1.64 1.84 2.07 2.33 2.62 2.95 TCG 43.80 41.40 39.20 36.90 34.60 32.10 29.50 26.70 55 SDT 77.90 86.90 95.90 104.90 113.90 122.80 131.50 140.20 (12.78) KW 1.29 1.47 1.66 1.87 2.09 2.35 2.64 2.97 See notes on page 15 14 CONDENSER ONLY RATINGS (CONT) SST CONDENSER ENTERING AIR TEMPERATURES °F (°C) °F (°C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) r 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) TCG 31.40 29.80 28.20 26.40 24.60 22.70 20.60 18.50 30 (-1.11) SDT 68.70 78.10 87.50 96.80 106.20 115.50 124.70 134.00 KW 1.48 1.69 1.91 2.14 2.40 2.69 3.04 3.44 TCG 34.70 32.90 31.10 29.20 27.20 25.10 22.80 20.50 35 (167) SDT 70.00 79.30 88.60 97.90 107.20 116.40 125.60 134.80 KW 1.48 1.70 1.91 2.15 2.41 2.70 3.05 3.45 TCG 38.20 36.20 34.20 32.10 29.90 27.60 25.20 22.60 40 (4.44) SDT 71.30 80.50 89.80 99.10 108.30 117.40 126.50 135.60 KW 1.49 1.70 1.92 2.16 2.42 2.72 3.06 3.45 TCG 42.00 39.80 37.60 35.30 32.90 30.30 27.70 24.80 45 (7.22) SDT 72.80 81.90 91.10 100.30 109.40 118.50 127.50 136.40 KW 1.50 1.72 1.94 2.18 2.44 2.73 3.07 3.46 TCG 46.00 43.60 41.10 38.60 36.00 33.20 30.20 27.20 50 (10.0) SDT 74.40 83.40 92.50 101.60 110.60 119.60 128.50 137.30 KW 1.52 1.74 1.96 2.20 2.46 2.75 3.08 3.47 TCG 50.20 47.60 44.90 42.10 39.20 36.20 32.90 29.60 55 (12.78) SDT 76.10 85.00 94.00 103.00 111.90 120.80 129.50 138.20 KW 1.54 1.76 1.98 2.22 2.48 2.77 3.10 3.48 TCG 41.50 39.50 37.40 35.40 33.20 30.80 28.20 25.40 30 (-1.11) SDT 73.40 82.60 91.90 101.20 110.40 119.50 128.60 137.50 KW 2.05 2.30 2.57 2.87 3.21 3.60 4.05 4.56 TCG 45.70 43.40 41.20 38.90 36.50 33.90 31.10 28.10 35 (167) SDT 75.10 84.30 93.40 102.60 111.70 120.80 129.70 138.60 KW 2.08 2.33 2.60 2.90 3.24 3.63 4.08 4.60 TCG 50.10 47.70 45.20 42.70 40.10 37.20 34.20 30.90 40 (4.44) SDT 77.00 86.00 95.10 104.10 113.20 122.10 131.00 139.70 KW 2.12 2.36 2.63 2.93 3.27 3.67 4.12 4.64 TCG 54.80 52.20 49.50 46.70 43.80 40.70 37.40 33.80 45 (7.22) SDT 78.90 87.80 96.80 105.80 114.70 123.50 132.20 140.80 KW 2.15 2.39 2.66 2.96 3.31 3.71 4.16 4.69 TCG 59.90 56.90 54.00 51.00 47.80 44.40 40.70 36.80 50 (10.0) SDT 80.90 89.80 98.60 107.50 116.30 125.00 133.60 142.00 KW 2.19 2.43 2.70 3.00 3.34 3.74 4.20 4.72 TCG 65.20 62.00 58.80 55.40 51.90 48.20 44.20 39.90 55 (12.78) SDT 83.10 91.80 100.50 109.30 117.90 126.50 134.90 143.20 KW 2.24 2.47 2.73 3.03 3.38 3.78 4.24 4.76 TCG 53.00 50.30 47.70 45.10 42.40 39.40 36.00 32.40 30 (-1.11) SDT 76.00 85.10 94.30 103.50 112.70 121.70 130.60 139.40 KW 2.59 2.90 3.23 3.61 4.03 4.52 5.08 5.71 TCG 58.30 55.30 52.50 49.70 46.60 43.30 39.70 35.70 35 (167) SDT 78.00 87.00 96.10 105.20 114.20 123.10 131.90 140.60 KW 2.64 2.94 3.28 3.65 4.08 4.58 5.14 5.78 TCG 63.90 60.70 57.60 54.50 51.10 47.50 43.60 39.30 40 (4.44) SDT 80.00 88.90 97.90 106.90 115.80 124.70 133.30 141.90 KW 2.69 2.99 3.32 3.70 4.14 4.63 5.20 5.84 TCG 70.00 66.50 63.10 59.60 55.90 51.90 47.60 42.90 45 (7.22) SDT 82.20 91.00 99.90 108.80 117.60 126.30 134.80 143.20 KW 2.74 3.04 3.38 3.76 4.19 4.69 5.27 5.91 TCG 76.40 72.60 68.80 65.00 60.90 56.50 51.80 46.70 50 (10.0) SDT 84.60 93.30 102.00 110.70 119.40 127.90 136.30 144.50 KW 2.80 3.10 3.43 3.81 4.25 4.76 5.33 5.97 TCG 83.30 79.10 74.90 70.60 66.10 61.30 56.10 50.60 55 SDT 87.00 95.60 104.20 112.80 121.20 129.60 137.80 145.80 (12.78) KW 2.86 3.15 3.49 3.87 4.31 4.82 5.39 6.04 * AHRI listing applies only to systems shown in Combination Ratings table. KW - Outdoor Unit Kilowatts Only. SDT - Saturated Temperature Leaving Compressor (°F) SST - Saturated Temperature Entering Compressor (°F/°C) TCG - Gross Cooling Capacity (1000 Btuh) 15 GUIDE SPECIFICATIONS GENERAL System Description Outdoor —mounted, air—cooled, split —system air conditioning unit suitable for ground or rooftop installation. Unit consists of a scroll —type hermetic compressor, an air—cooled coil, propeller —type condenser fan, and a control box. Unit will discharge supply air horizontally as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or furnace. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c—UL approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500—hsalt spray test. — Air—cooled condenser coils will be leak tested and pressure tested — Unit constructed in IS09001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. PRODUCTS Equipment — Factory assembled, single piece, air—cooled air conditioning unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Purono (R-410A), and special features required prior to field start—up. Unit Cabinet Fans — Unit cabinet will be constructed of galvanized steel and bonderized. — Condenser fan will be direct —drive propeller type, discharging air horizontally. Copyright 2017 Bryant Heating & Cooling Systems • 7310 W. Morris St. • Indianapolis, IN 46231 AIR—COOLED, SPLIT —SYSTEM AIR CONDITIONER 124ANS 1-1/2 TO 5 NOMINAL TONS — Condenser fan motors will be totally enclosed, 1—phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be a scroll —type, hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration Components — Refrigeration circuit components will include liquid —line front —seating shutoff valve with sweat connections, vapor —line front —seating shutoff valve with sweat connections, system charge of Puron@ (R-410A) refrigerant, and compressor oil. — Unit will be equipped with high—pressure switch and filter drier for Puron refrigerant. Operating Characteristics — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption at full load will not exceed kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evaporator at °F/°C wet bulb and °F/°C dry bulb, and air entering the unit at °F/°C. — The system will have a SEER of Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Nominal unit electrical characteristics will be v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Edition Date: 10/17 Catalog No: PDS124ANS-05 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 16 Replaces: PDS124ANS-04