Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-0654_Other_5.29.2023_1.24.50_PM_3573584
• PlusOneTm Energy Efficiency offers minimum of 20 SEER and 13 HSPF system performance across all capacities. • PlusOneTm Expanded Valve Space — 3"-4"-5" service valve space — provides a minimum working area of 27-square inches for easier access • PlusOneTm Triple Service Access — 15" wide, industry leading corner service access — makes repairs easier and faster. The two fastener removable corner allows optimal access to internal unit components. Individual louver panels come out once fastener is removed, for faster coil cleaning and easier cabinet reassembly • EcoNetTm Enabled product. The EcoNet Smart Home System provides advanced air & water control for maximum energy savings and ideal comfort. • New composite base pan — dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed • Powder coat paint system — for a long lasting professional finish • The Copeland ScrolITM Variable Speed Compressor has a mod- ulating technology which provides more precise temperature control, lower humidity and greater efficiency. The overdrive feature provides cooling load up to 107°F and heating load down to 7°F. • Modern cabinet aesthetics — increased curb appeal with visu- ally appealing design • Equipped with electronic expansion valve to precisely control variable refrigerant flow. • Improved tubing design — reduces vibration and stress, making unit quieter and reducing opportunity for leaks • Optimized defrost characteristics - decrease defrosting and provide better home comfort UP20 Series Efficiencies up to 20 SEER/14.5 EER/13 HSPF Nominal Sizes 2, 3, 4 & 5 Ton [7.03, 10.6, 14.06 & 17.6 kW] Cooling Capacities 17.3 to 60.5 kBTU [5.7 to 17.7 kW] & LISTED "Proper sizing and installation of equipment is critical to achieve opti- mal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet Energy Star. Ask your Contractor for details or visit www.energystargov." Iri LcoNet TM • Optimized reversing valve sizing — improves shifting performance for quieter unit operation and increased life of the system • Enhanced mufflers — help to dissipate vibration energy for qui- eter unit operation • Integrated heat pump lift receptacle — allows standard CPVC stands to be inserted into the base • Curved louver panels —provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity • Optimized fan orifice — optimizes airflow and reduces unit sound • Rust resistant screws — confirmed through 1500-hour salt spray testing • Diagnostic service window with two -fastener opening — provides access to the high and low pressure. • External gauge port access — allows easy connection of "low -loss" gauge ports • Single -row condenser coil (up thru 4 tons) — makes unit lighter and allows thorough coil cleaning to maintain "out of the box" performance • 35% fewer cabinet fasteners and fastener -free base — allow for faster access to internal components and hassle -free panel removal • Service trays — hold fasteners or caps during service calls • QR code — provides technical information on demand for faster service calls • Fan motor harness with extra long wires allows unit top to be removed without disconnecting fan wire. • High and low pressure standard on all models. FORM NO. P22-81 1 Table of Contents UP20 Series StandardFeature......................................................................................................3 AvailableSKUs........................................................................................................3 Features& Benefits..............................................................................................4-8 Model Number Identification..............................................................................9-10 General Data/Electrical Data..................................................................................11 Accessories..........................................................................................................12 WeightedSound Power..........................................................................................12 Smart Home Systems......................................................................................13-14 UnitDimensions......................................................................................................15 Clearances..............................................................................................................16 WiringDiagrams....................................................................................................17 Refrigerant Line Size Information......................................................................18-19 Performance Data..................................................................................................20 GuideSpecifications..............................................................................................21 LimitedWarranty....................................................................................................22 Standard Feature/Available SKUs UP20 Series Standard Feature Table STANDARD FEATURES Feature 24 36 48 60 R-410A Refrigerant -1/ -1/ Maximum SEER 20 20 20 20 Maximum EER 14.5 14 13 13 EcoNet Enabled ,/ ✓ ,/ ,/ Copeland ScroIITM Variable Speed Compressor ,/ Compressor Sound Blanket Variable speed outdoor fan motor Swept wing fan blade Field Installed Filter Drier Front Seating Service Valves ,/ Internal Pressure Relief Valve Internal Thermal Overload ✓ �/ ,/ �/ Low Ambient capability 3-4-5 Expanded Valve Space Composite Basepan 1" Screw Control Box Access 15" Access to Internal Components Quick release louver panel design No fasteners to remove along bottom Optimized Venturi Airflow ,/ Single row condenser coil ✓ 2 Row Powder coated paint Rust resistant screws QR code External gauge ports ,/ Service trays V ✓ = Standard Available SKUs Available Models Description UP2024AJVCA 2 ton EcoNet'' Enabled inverter driven Ruud Ultra` Series Variable Speed Heat Pump-208/230/1/60 UP2036AJVCA 3 ton EcoNet'' Enabled inverter driven Ruud Ultra'" Series Variable Speed Heat Pump-208/230/1/60 UP2048AJVCA 4 ton EcoNet'' Enabled inverter driven Ruud Ultra'" Series Variable Speed Heat Pump-208/230/1/60 UP2060AJVCA 5 ton EcoNetf' Enabled inverter driven Ruud Ultra'" Series Variable Speed Heat Pump-208/230/1/60 Features & Benefits UP20 Series Introduction to UP20 Heat Pump The UP20 is our EcoNetTm Enabled, Inverter Driven Ultra TM Series Variable Speed Heat Pump and is part of the Ruud Heat Pump product line that extends from 13 to 20 SEER. This highly featured and reliable heat pump is designed for years of reliable, efficient operation when matched with Ruud indoor aluminum evaporator coils and furnaces or air handler units with aluminum evaporators. The EcoNet Smart Home System is an integrated system for a home's Heating, Cooling and Water Heating equipment — allow- ing homeowners to manage the products that consume up to 65% of the their home's energy. EcoNet sets Ruud, and our distributor and contractor customers, apart in the industry with a unique, advanced and efficient technology solution. The UP20 Ultra TM Series inverter driven Variable Speed Heat Pump is exclusively designed to operate with the EcoNetTM Smart Home System. Developed by Ruud, The EcoNet Smart Home System allows homeowners to manage select high - efficiency, EcoNet Enabled air conditioners, heat pumps, gas furnaces, air handlers and water heaters from anywhere. EcoNet Enabled products in a home are connected through standard HVAC wiring; then contractors have the option of adding an EcoNet WiFi Kit (1❑) so the homeowner can access everything remotely through a free mobile app or mobile -friendly website. The Control Center (❑2) acts as both a thermostat for the heat- ing and cooling system, and a remote control for connected water heaters. C W�11-irla -6 Along with the EcoNet Smart Home System the UP20 is matched with the RHMV Constant CFM Variable Speed EcoNet Enabled Air Handler (❑s) or can be applied in a Furnace applica- tion with the EcoNet Enabled Two -Stage Variable Speed R802V or U96V Gas Furnaces or the fully modulating U97V and RCF Aluminum Cased Furnace Coils with EEV (®). See individual specification documents for more details of the indoor products. Features & Benefits UP20 Series How It Works The EcoNetTm Enabled, Inverter Driven Ruud® Ultra TM Series Variable Speed Heat Pump's (❑5) variable speed outdoor unit control (VSODU) (©) continuously monitors the EcoNet control temperature and humidity set point, suction pressure (❑� ), suction temperature (®), outdoor coil temperature (10 and outdoor temperature (io) and feeds this information to the Copeland Inverter Control Motor Drive (11 ). The Copeland Inverter Control Motor Drive converts AC to DC power, sends it to the Copeland ScrolITM variable speed compressor (12 ) Brushless Permanent Magnet motor (BPM), dynamically adjust- ing its speed. Simultaneously the VSODU provides input to the ECM outdoor fan motor (13) which is equipped with the latest swept wing fan technology (ia) and the Electronic Expansion Valve (EEV) (Es) which syncs up with the compressor speed to deliver the exact capacity the home needs to meet its comfort requirements. The result of this advanced technology is signifi- cantly improved energy efficiency and comfort. Energy efficiency is improved by precise load matching, less cycling on and off and low amp gradual compressor, outdoor and indoor motor operation. Comfort is improved by precise temperature control, precise humidity control and extra capacity during extreme summer and cold weather conditions. Features & Benefits UP20 Series ❑0 4W.T*-,* System Component Descriptions EcoNet Control Center - (5-1): The EcoNet Control Center serves as the hub of communication for a home's Heating, Cool- ing and Water Heating systems and is required to operate an EcoNet Enabled Heating and Cooling system in a fully communi- cating mode. The EcoNet Control center displays detail diagnos- tic from outdoor and indoor connected units. See individual specification documents for more details of the EcoNet Control Center. EcoNet Cooling and Heating WiFi Module - (❑2) is required to remotely operate an EcoNet Enabled Heating and Cooling system from the EcoNet web portal and mobile apps. See indi- vidual specification documents for more details of the EcoNet Control Center. Variable Speed Outdoor Unit Control (VSODU) - (©) is where control wiring is hooked to the UP20. The VSODU control takes input from the EcoNet Control Center, outdoor suction tempera- ture and pressure sensors, outdoor air and coil temperatures and communicates to the Copeland Inverter Control Motor Drive, EEV, reversing valve, outdoor fan and indoor blower to precisely control system capacity output of the heat pump in heating and cooling modes. It also is equipped with Dual Seven -Segment Display for technician interface, operation status and fault code communication. Two momentary buttons allow technician to initiate various operating modes. Various LED's communicate active EcoNet communication, microprocessor activity and EEV operation. See 1&0 for more details. The Copeland Inverter Control Motor Drive - (-1) converts incoming single-phase AC power to 3 phase DC simulated sine wave power. Once power is converted the Copeland Inverter Control Motor Drive varies frequency of the power to the com- pressor varying the compressor speed. The Copeland Inverter Control Motor Drive has active protection algorithms that keep the compressor safely inside its operating envelope. The Copeland ScrolITM Variable Speed compressor - (12 ) utilizes a Brushless Permanent Magnet Motor (BPM) that varies the Scroll speed, thus, varying the refrigerant flow. The robust scroll design has proven reliability over competing compressor technologies. Swept Wing Fan Blade - (ia) is the latest technology in out- door fans that increase efficiency and reduces air noise. The Electronic Expansion Valve (EEV) - (is) is an electroni- cally driven refrigerant control valve. A small stepper motor is used to open and close valve to precisely control refrigerant flow. It is controlled by the VSODU, which receives input from the pressure transducer and suction line temperature sensor to control the UP20 in the heating mode. The VSODU drives it fully open in the cooling mode. The EEV is superior to a TXV (ther- mostatic expansion valve) because the EEV controls superheat at the evaporator coil under varying load and refrigerant flow conditions, more precisely than traditional TXV's. The Filter - (16) is an electrical device that "cleans" the AC power component. This low pass filter only permits the passage of 60-Hertz signal to the inverter drive. The Pressure Transducer - (❑�) is used to measure suction pressure in the outdoor heat pump. The VSODU takes this input to operate the EEV and make decisions on system operation such as low ambient cooling. Various temperature sensors - are located on the Heat Pump. There is an outdoor air sensor (io ), an outdoor coil sensor (fl), a discharge line temperature sensor (not shown, located on discharge line), a suction line temperature sensor (®) and a compressor sump temperature sensor (not shown, located bot- tom of compressor). The VSODU uses these temperature mea- surements to operate the system. The Choke - (1�) is provided to absorb power spikes that might occur on the DC line. Ferrite Rings - (is) are iron cores through which AC power is looped keeping any electrical noise contained. They also reduce the induction of electrical transient into the DC drive. The Suction Accumulator - (is) prevents liquid refrigerant from entering the compressor. The Reversing Valve - (20) reverses the flow of refrigerant in cooling versus heating. Features & Benefits UP20 Series Features In addition all UP20 Ultra Series Inverter Driven Variable Speed Heat Pumps have the following features: 18 20 3 - © 6 8 ❑ ❑ 17 (17 ). Outdoor coil heights range from as short as 35" to 48". Our unique composite base (❑3) reduces sound emission, elimi- Disassembly to this degree and complete reassembly only takes nates rattles, significantly reduces fasteners, eliminates corrosion a first time service technician less than 10 minutes. (17 ) and has integrated brass compressor attachment inserts (®). Furthermore it has incorporated into the design, water manage- ment features, means for hand placement (❑5) for unit maneu- vering, screw trays (©) and inserts for lifting off unit pad. (❑f ) Service Valves (®) are rigidly mounted in the composite base with 3" between suction and discharge valves, 4" clearance below service valves and a minimum of 5" above the service valves, creating industry leading ease of installation. The minimum 27 square -inches around the service valves allows ample room to remove service valve schrader prior to brazing, plenty of clearance for easy brazing of the suction and discharge lines to service valve outlets, easy access and hookup of low loss refrig erant gauges (❑9 ), and access to the service valve caps for opening. Controls are accessed from the corner of the unit by removing only one fastener from the control access cover, revealing the industry's largest 15" wide and 22" tall control area (-0 ). With all this room in the control area the high voltage electrical whip (11 ) can easily be inserted through the right size opening in the bottom of the control area. Routing it leads directly to lugs for connection. The low voltage control wires (12) are easily con- nected to the units VSODU terminal strip. The service window (14) can be removed by removing two screws, to access the EEV and view interior of unit. (15) (High and low pressure is standard on UP20 models). If in the rare event, greater access is needed to internal compo- nents, such as the compressor, the entire corner of the unit can be removed along with the top cover assembly to have unprece- dented access to interior of the unit (is ). Extra wire length is incorporated into each outdoor fan and compressor so top cover and control panel can be positioned next to the unit. Or with minimal effort the plug can be removed from the compres- sor and the outdoor fan wires can be removed from the VSODU to allow even more uncluttered access to the interior of the unit All units utilize formed louver panels which provide industry leading coil protection. Louver removal for coil cleaning is accomplished by removing one screw and lifting the panel out of the composite base pan. (19) All UP20 units utilize single row coils (ia) making cleaning easy and complete, restoring the performance of the air conditioner back to out of the box performance levels year after year. The outdoor fan motor has sleeve bearings and is inherently protected. The motor is totally enclosed for maximum protection from weather, dust and corrosion. (20) Access to the outdoor fan is made by removing four fasteners from the fan grille. The out- door fan can be removed from the fan grille by removing 4 fas- teners in the rare case outdoor fan motor fails. Each cabinet has optimized composite (21) fan orifice assuring efficient and quiet airflow. INV21 The entire cabinet has post powder paint (22) achieving 1000 hour salt spray rating, allowing the cabinet to retain its aesthetics throughout its life. _ 26 22 25 24 = 23 i The Copeland ScrolIT" Variable Speed compressors (2s) with standard internal pressure relief and internal thermal overload are used on all capacities assuring longevity of high efficient and quiet operation for the life of the product. All UP20 Heat Pump come standard with high and low pressure switches reinforced vinyl compressor sound covers containing a 11/2 inch thick batt of fiberglass insulation and open edges are sealed with a 1 inch wide hook and loop fastening tape for superior sound quality. Features & Benefits UP20 Series Features (con't.) Each unit is shipped with filter drier for field installation and will trap any moisture or dirt that could contaminate the refrigerant system. All cabinets have industry leading structural strength due to the composite base pan (23 ), interlocking corner post (24) formed curved louver panels ( 25) and drawn top cover (26) making it the most durable cabinet on the market today. Each UP20 capacity has undergone rigorous psychometric test- ing to assure performance ratings of capacity, SEER and a 0� S EER per AHRI Standard 210/240 rating conditions. Also uO each unit bears the UL mark and each unit is certified to UL 1995 safety standards. Each unit has undergone specific strain and modal testing to assure tubing (27) is outside the units natural frequency and that the suction and discharge lines connected to the compressor withstand any starting, steady state operation, or shut down forces imposed by the compressor. All units have been sound tested in sound chamber to AHRI 270 rating conditions, and A -weighted Sound Power Level tables produced, assuring units have acceptable noise qualities (see page 12). Each unit has been ran in cooling operation at 95°F and sound ratings for the UP20 range from as low as 56 dBA at low speed and as high as 76 dBA at 95°F rated conditions. All units have been ship tested to assure units meet stringent "over the road" shipping conditions. As manufactured, all units in the UP20 family have cooling capa- bility to 40°F. Addition of low ambient control will allow the unit to operate down to 0°F. Factory testing is performed on each unit. All component parts meet well defined specification and continually go through receiving inspections. Each component installed on a unit is scanned, assuring correct component uti- lization for a given unit capacity and voltage. All condenser coils are leak tested with pressurization test to 550#'s and once installed and assembled, each units' complete refrigerant system is helium leak tested. All units are fully charged from the factory for up to 15 feet of piping. All units are factory run tested. The UP20 has a 10-year conditional unit replacement warranty (registration required) and a 10 year limited parts warranty. Optional Accessories (Refer to accessory chart for model #) 311/611/1211 • Gray high density polyethylene feet are available to raise unit off of mounting surface away from moisture Accessories EcoNet Control Center The EcoNet Control Center serves as the hub of communication for a home's Heating, Cooling and Water Heating systems, and is required to operate an EcoNet Enabled Heating & Cooling system in a fully communicating mode. UETST601SYS WiFi Kit for Heating and Cooling Systems pt. .. 4 iiiimp- - a REWRA630SYS Thermostor Kit - RXHT A02 The WiFi kit is required to remotely operate EcoNet Enabled Heating and Cooling Systems from the EcoNet Web portal and mobile apps. U P 20 24 A Brand Product SEER Capacityt Major Series* Category BTU/HR Ruud P - Heat Pump 13 - 13 SEER 18 - 18,000 [5.28 kW] A - 1st Design 14 - 14 SEER 24 - 24,000 [7.03 kW] 15 - 15 SEER 30 - 30,000 [8.79 kW] 17 - 17 SEER 36 - 36,000 [10.55 kW] 20 - 20 SEER 42 - 42,000 [12.31 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] *See page 3 for available SKU's. tTwo-stage and inverter available in whole capacities only. J V C A Voltage Type Controls Minor Series** Option Code J - 1 ph, 208-230/60 1 - Single -stage C - Communicating A - 1st Design N/A C - 3ph, 208-230/60 2 - Two -stage N - Non -Communicating D - 3ph, 460/60 V - Inverter P - Piston U A 20 24 A J V C B Brand Product SEER Capacityt Major Series* Voltage Type Controls Minor Series** Option Category BTU/HR Cade Ruud A - Air Conditioners 13 -13 SEER 18-18,000 [5.28 kW] A -1st Design J -1 ph, 208-230/60 1 - Single -stage C - Communicating B - High N/A 14 -14 SEER 24 - 24,000 [7.03 kW] B - 2nd Design C - 3ph, 208-230/60 2 - Two -stage N - Non -Communicating and low 16 -16 SEER 30 - 30,000 [8.79 kW] V - Inverter pressure 17 -17 SEER 36 - 36,000 [10.55 kW] control 20 - 20 SEER 42 - 42,000 [12.31 kW] 48 - 48,000 [14.07 kW] 60 - 60,000 [17.58 kW] *See page 3 for available SKU's. tTwo-stage and inverter available in whole capacities only. R C F 24 17 S E A M Brand Product Type Capacity Width Efficiency Metering Major Orientation Category BTU/HR Device Series* Ruud C - Evap Coil F - Furn Coil 24 - 24,000 [7.03 kW] 14 - 14" S- Standard Eff. T-TXV A - 1st Design M - Multipoise H - Air -Handler 36 - 36,000 [10.55 kW] 17 - 17.5" M- Mid Eff. E-EEV V - Vertical only/ Coil 48 - 48,000 [14.07 kW] 21 - 21" H- High Eff. P-Piston convertible 60 - 60,000 [17.58 kW] 24 - 24.5" H - Ded. Horizontal only NOTE: The above Model Number ID's are for reference only. Available SKU's are listed on the standard features/available SKU page of model spec sheet. [ ] Designates Metric Conversions C A Casing Minor Series** Option Code C - Cased A - 1 st Design N/A U - Uncased cK N Q 0M NZ m m' 3 rn a' CD 3 a m U 96 V A 70 2 3 17 M Brand Series Motor Major Rev Input Stages Air Flow Cabinet Configuration BTU/HR Width Ruud 90 - 90 AFUE V - Variable speed A - 1st Design 040 - 42,000 [12.31 kW] 1 Single -stage 3 - up to 3 ton 14 - 14" M - Multi 92 - 92 AFUE T - Constant 060 - 56,000 [16.41 kW] 2 Two -stage 5 - 3 1/2 up to 5 ton 17 - 17.5" 95 - 95 AFUE Torque 070 - 70,000 [20.51 kW] M - Modulating 21 - 21" 96 - 96 AFUE (X-13)085 - 84,000 [24.62 kW] 24 - 24.5" 97 - 97 AFUE P - PSC 100 - 98,000 [28.72 kW] 115 - 112,000 [32.82 kW] .I'. ' •. U 80 2 V A 075 3 17 M Brand Series Stages Motor Major Rev Input Air Flow Cabinet Configuration BTU/HR Width Ruud 80 - 80+ AFUE 1 Single -stage V - Variable speed A - 1st Design 050 - 50,000 [15 kW] 3 - up to 3 ton 14 - 14" M - Multi 2 Two -stage T - Constant Torque (X-1 3)075 - 75,000 [22 kW] 4 - 2 1/2 to 4 ton 17 - 17.5" D -Down P - PSC premium 100 - 100,000 [29 kW] 5 - 3 1/2 up to 5 ton 21 - 21" Z - Down & S - PSC standard 125 - 125,000 [37 kW] 24 - 24.5" zero clearance 150 - 150,000 [44 kW] down flow S A Nox Minor Rev X - Low Nox A - 1 st Design S - Standard S A Nox Minor Rev X - Low Nox A - 1 st Design S - Standard R H M V 36 17 S E A C J A 000 Brand Product Stages of Motor Type Capacity Width Coil Size Metering Major Controls Voltage Minor Factory Heat Option Category Airflow BTU/HR Device Series' Series" Cap Code Ruud H -Air 1 - Single -Stage V - Variable 24 - 24,000 [7.03 kW] 14 - 14" S - Standard T - TEV A - 1 st Design C -Communicating J - 1 ph, 208-240/60 A - 1 st Design 00 - no "TBD Handler 2 - Two -Stage Speed 36 - 36,000 [10.55 kW] 17 - 17.5" Eff. E - EEV N -Non-comm factory heat M - Modulating T - Constant 48 - 48,000 [14.07 kW] 21 - 21" M -Mid Eff. P - Piston with option Torque 60 - 60,000 [17.58 kW] 24 - 24.5" H - High Eff. code P - PSC NOTE: The above Model Number ID's are for reference only. Available SKU's are listed on the standard features/available SKU page of model spec sheet. [ ] Designates Metric Conversions Cg N Q OCD NZ m m' En a' m 3 a m General Data/Electrical Data UP20 Series Physical Data Model No. UP2024A UP2036A UP2048A UP2060A Nominal Tonnage 2.0 3.0 4.0 1 5.0 Valve Connections Liquid Line O.D. — in. 3/8 3/8 3/8 3/8 Suction Line O.D. — in. 3/4 3/4 7/8 7/8 Refrigerant (R-410A) furnished oz.' 135.2 Coming Soon 215.2 Coming Soon Compressor Type Scroll Outdoor Coil Net face area — Outer Coil 21.5 Coming Soon 32.5 Coming Soon Net face area — Inner Coil — Coming Soon — Coming Soon Tube diameter— in. 3/8 Coming Soon 3/8 Coming Soon Number of rows 1 Coming Soon 1 Coming Soon Fins per inch 20 Coming Soon 22 Coming Soon Outdoor Fan Diameter— in. 26 Coming Soon 26 Coming Soon Number of blades 3 Coming Soon 3 Coming Soon Motor hp 1/5 Coming Soon 1/2 Coming Soon CFM 4375 Coming Soon 4995 Coming Soon RPM 731 Coming Soon 842 Coming Soon watts 95 Coming Soon 108 Coming Soon Shipping weight — lbs. 231 Coming Soon 301 Coming Soon Operating weight — lbs. 223 Coming Soon 293 Coming Soon Electrical Data Line Voltage Data (Volts -Phase -Hz) 208/230-1-60 208/230-1-60 208/230-1-60 208/230-1-60 Maximum overcurrent protection (amps)2 45 Coming Soon 70 Coming Soon Minimum circuit ampacity3 27 Coming Soon 46 Coming Soon Compressor Rated load amps 21 Coming Soon 32 Coming Soon Locked rotor amps 35 Coming Soon 50 Coming Soon Condenser Fan Motor Full load amps 1.4 Coming Soon 5.3 Coming Soon Locked rotor amps N/A Coming Soon N/A Coming Soon 'Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. 2HACR type circuit breaker of fuse. 311efer to National Electrical Code manual to determine wire, fuse and disconnect size requirements. Accessories/Weighted Sound Power UP20 Series Accessories Model No. UP2024 UP2036 UP2048 UP2060 EcoNet Control Center UETST601SYS UETST601SYS UETST601SYS UETST601SYS Wil'i Kit for Heating & Cooling REWRA630SYS REWRA630SYS REWRA630SYS REWRA630SYS Compressor sound cover STD STD STD STD Heat pump Riser 6 in. 686020 686020 686020 686020 Supply Return Sensor RXHT-A02 RXHT-A02 RXHT-A02 RXHT-A02 Rheem Show Unit Shell RXHD-CU4 RXHD-CU4 RXHD-CU4 RXHD-CU4 Weighted Sound Power Level (dBA) RP20 Sound Power Level Sound Power Full Octave Linear Sound Power Level dB - Center Frequency - Hz Sound Power Model Level [dB(A)l Level [dB(A)l Low Speed/ with Sound High Speed 125 250 500 1000 2000 4000 6300 8000 Blanket 59 38.6 35.9 42.2 43.3 39.2 44.8 55.1 40.4 UP2024 69 44.8 52.5 60.1 58.7 57.5 49 49.9 44.2 64 33.7 45.1 1 51.6 53.5 51.8 45.4 1 48.4 42.4 UP2036 70 50.3 53.3 58.9 58 55.9 49.5 49.2 45.4 Sound Blankets UP2048 59 29.9 38.3 43.1 49.4 42.7 46.4 40.9 38.9 - Standard 72 41.1 47.9 61.2 59.4 57.4 50.6 48.9 45.8 59 41.1 40.8 45.6 48.6 43.4 41 40.2 38.9 UP2060 71 45 54.1 61.1 57.5 55.9 50.1 48 47.3 NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI) Smart Home Systems UP20 Series Integrated Controls r�EcoNet TM EcoNet is smart, new technology developed exclusively by Ruud that allows Heating, Cooling, and Water Heating products to communicate with each other on one integrated network. Easy to Setup, Easy to Use, Easy to Save • Built with our 360°+1 design philosophy, it is optimized for InstallabilityTM, Performance, Integration & Serviceability • Controls 65%t or more of a typical home's energy use from a single device • Can reduce energy costs by up to 30%tt Features • Added support for new EEV (Electronic Expansion Valve) Air Handlers, Air Condi- tioners and Heat Pumps' • Rapid installation with standard 4-wire configuration • Automatically configures communicating equipment with optimal settings • Adapts to home decor through interchangeable faceplates and adjustable background coloring • Full -color, 4.7" LCD touchscreen display with easy -to -read icons and text • Convenient date, time and indoor/outdoor temperature indications • 5 operating modes with short -cycle protec- tion (Heat, Cool, Auto, Emergency Heat, Fan Only) • 7-Day programmable schedule with Smooth Arrival & Whole Home Vacation options • Detailed operating status, alarm history, and audible alerts • Supports humidifier accessories or over- cool based dehumidification • One -touch access to Water Heater Managementttt • Easily manage from anywhere in the world with the compatible WiFi Module & EcoNet app for smart phones and tablets t Source — Department of Energy tt When compared to non -programmable thermostats. Source: ENERGY STAR' for Programmable Thermostats ttt Requires wired connection to EcoNet Enabled Electric or Hybrid Water Heaters EcoNet Control Center Compatibility EcoNetTM Control Center Home control with intuitive LCD touchscreen navigation UETST601SYS OFFERINGS HEATING & COOLING WATER HEATING Product Categories Gas Furnaces Air Handlers Air Conditioners Electric Heat Pumps Tank Hybrid Gas Powered Models Tank HB50 Damper Ending in Models Tank EC2 Models U ETST601 SYS J J J J J J J yt J J yt J J J �t J J J *Available in 2016 **Electronic Expansion Valve (EEV) Models * Comfort Control2 SystemTm Translator for EcoNet Required Installation of the RETRN620CC2 Comfort Contro12 SystemTm Translator on the outdoor unit's control board is required to operate Comfort Contro12 SystemTm Air Conditioner and Heat Pump models (****-JEC) with an EcoNet Control Center in a fully communicating mode when matched with EcoNet Enabled Furnaces or Air Handlers*. Smart Home Systems UP20 Series The EcoNetTM WiFi Kit for Heating & Cooling Systems (REWRA630SYS) provides remote control of EcoNet 0 Ecc Net TM Enabled air and water products from smart phones, tablets, and personal computers using the home's internet connection. Features • Enables remote operation from: • 24" Port -to -Port Connection Cable - The EcoNet App on Apple° mobile devices • 1 " x 2" Double Adhesive Mounting Tape (iPhone°, iPad°, & iPod° Touch) using iOS . RJ12 Y Splitter (for use with version 7.0 or later communicating electric water heaters) - The EcoNet App on AndroidTm based smart phones and tablets using AndroidTM version 4.4 orlater - Recent versions of popular web browsers such as Internet Explorer, Chrome, Safari, etc. • Designed for use with EcoNet communi- cating HVAC Systems • Compatible with 802.11 b/g/n WiFi networks • WPA-2 Security using AES/CCMP • Status LEDs: - Power & Equipment Connection Status - Home Network WiFi Status - Internet Connection Status • "WLAN SETUP" factory reset button WiFi Kit Components • EcoNet WiFi Module • Installation Instructions • V Power Adapter • Junction Box Compatibility • Works with any HVAC System which includes an EcoNet Enabled furnace or air handler and an EcoNet control center. Warranty • 1 Year from installation date EcoNet WiFi Kit for Heating & Cooling Systems REWRA630SYS HVAC Connection Illustration - R- R 1W 7 am -E1- o -E1- -E1- -E2- I -E2- -E2- 1. 1 Unit Dimensions UP20 Series Unit Dimensions MODEL NO. OPERATING SHIPPING H (Height) L (Length) W (Width) H (Height) L (Length) W (Width) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm UP2024 35 990 35.75 908 35.75 908 37.56 1055 39.37 999 39.64 1006 UP2036 39 990 35.75 908 35.75 908 41.56 1056 39.37 999 39.64 1006 UP2048 51 1295 35.75 908 35.75 908 53.56 1360 39.37 999 39.64 1006 UP2060 1 51 1295 1 35.75 1 908 35.75 1 908 1 53.56 1 1360 39.37 999 1 39.64 1006 ALLOW 60" [1524 mm] OF CLEARANCE 'E PANELS/ CONNECTIONS / HIGH & LOW GE ACCESS 124" [610 mm] OF CLEARANCE Min IIVLC I LVV V CfIJ MLLIIVV 6" [152 mm] MIN. OF CLEARANCE ALL SIDES 12" [305 mm] RECOMMENDED [ ] Designates Metric Conversions ST-A1226-02-00 CLEARANCES 6" (152.4) 24" (609.6) Service 18" (457.2) 24" (609.6) 24" recommended 6" minimum 24" (609.6) Service 24" (609.6) 24" recommended 6" minimum NOTE: NUMBERS IN () = mm IMPORTANT. When installing multiple units in an alcove, roof well or partially enclosed area, ensure there is adequate ventillation to prevent re -circulation of discharge air. 12" (304.8) 24" (609.6) Service ST-A1225-01-00 Cn R1 w O-3 cn m m F5' I N Wiring Diagram/Application Guidelines UP20 Series Control Wiring FIGURE 2 TYPICALECONET COMMUNICATING SYSTEM"m WIRING DIAGRAM Indoor Unit WIRING INFORMATION Line Voltage -Field Installed ------ -Factory Standard Application Guidelines Communicating Thermostat E1 E2 qR CQ ----r--+--- -------------------- _u f-------------------- i --� �, r' Outdoor Unit 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01 -in. wc. 2. Minimum outdoor operation air temperature for cooling mode without low -ambient operation accessory is 55°F (12.8°C). 3. Maximum outdoor operating air temperature is 125°F (51.7°C). 4. For reliable operation, unit should be level in all horizontal planes. 5. Use only copper wire for electric connections at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. 6. Do not apply capillary tube indoor coils to these units. 7. Factory — supplied filter drier must be installed. Refrigerant Line Size Information R-410A System Capacity Model Liquid Line Size Connection Size (Inch I.D.) [mm] Liquid Line Size (inch O.D.) [mm] Liquid Line Selection chart Elevation (Above or Below) Total Equivalent Length - 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 125 [45.72] 150 [45.72] 175 [53.3, V]2 .58]250 [76.20] 275 [83.82] 300 [91.44] Maximum Vertical Separatio 24 3/8" [9.53] 1/4 [6.35] 25 [7.62] 50 [15.241 35 [10.67] 15 [4.57] N/R N/R N/R 60 [182 ] 90 [27.4; ] 95 [28.91 ] N/R N/R N/R 5/16 [7.94] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 75 [22.86] 70 [21.34] 50 [15.24] 45 [13.72] 40 [12.19] 35 [10.67] 3/8 [9.53] 25 [7.62] 50 [15.241 75 [22.861 95 [28.961 90 [27.431 90 [27.431 85 [25.911 80 [24.381 80 [24.381 80 [24.38] 7/16 [11.121 25 [7.62] 50 [15.241 75 [22.861 100 [30.48] 95 [28.96] 95 [28.96] 95 [28.96] 95 [28.961 90 [27.43] 90 [27.43] 1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 100 [30.48] 100 [30.48] 100 [30.48] 100 [30.41 81 N/R 100 [30.48] 100 [30.48] 95 [28.96] 95 [28.96] 1/4 [6.35] 25 [7.62] N/R N/R N/R N/R N/R N/R N/R N/R N/R 36 3/8" [9.53] 5/16 [7.94] 25 [7.62] 50 [15.241 60 [18.291 45 [13.721 30 [9.14] 20 [6.11 5 [1.5; 65 [19.8 ] 85 [25.9- ] N/R N/R N/R N/R 3/8 [9.53] 25 [7.62] 50 [15.241 75 [22.86] 80 [24.381 75 [22.861 70 [21.341 55 [16.761 50 [15.241 50 [15.241 45 [13.721 7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 90 [27.43] 90 [27.43] 85 [25.91] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86] 1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 95 [28.96] 95 [28.96] 90 [27.43] 90 [27.4; 3] N/R 90 [27.43] 90 [27.43] 85 [25.91] 85 [25.911 1/4 [6.35] 20 [6.1] N/R N/R N/R N/R N/R N/R N/R N/R N/R 48 3/8" [9.53] 5/16 [7.94] 25 [7.62] 50 [15.241 35 [10.671 20 [6.1] N/R N/R N/R 50 [15.2, ] N/R 35 [10.67] N/R 30 [9.14] N/R 25 [7.62] N/R 20 [6.1] 3/8 [9.53] 25 [7.62] 50 [15.24] 70 [21.34] 65 [19.81] 60 [18.29] 55 [16.76] 7/16 [11.12] 25 [7.62] 50 [15.24] 75 [22.86] 80 [24.38] 75 [22.86] 75 [22.86] 70 [21.3, 80 [24.31 4] 8] 65 [19.81] 65 [19.81] 60 [18.29] 60 [18.29] 1/2 [12.71] 25 [7.62] 50 [15.24] 75 [22.86] 85 [25.91] 85 [25.91] 80 [24.38] 80 [24.38] 75 [22.86] 75 [22.86] 75 [22.861 1/4 [6.35] N/R N/R N/R N/R N/R N/R N/R ON/R N/R N/R N/R N/R 60 3/8" [9.53] 5/16 [7.94] 25 [7.62] 10 [3.05] N/R N/R N/R N/R N/R N/R 40 [12.1! ] N/R N/R N/R 3/8 [9.53] 25 [7.62] 50 [15.24] 40 [12.19] 30 [9.14] 20 [6.1] 10 [3.05] N/R N/R N/R N/R 7/16 [11.12] 25 [7.62] 50 [15.24] 60 [18.29) 55 [16.76] 50 [15.24] 45 [13.72] 35 [10.671 30 [9.14] 25 [7.62] 20 [6.1] 1/2 [12.711 25 [7.62] 50 [15.24] 65 [19.811 65 [19.81] 60 [18.291 60 [18.291 55 [16.7 NEENIELL55 [16.76] 50 [15.241 50 [15.241 45 [13.72] NOTES: N/R = Application not recommended. Grey =This application is acceptable, but the long line guidelines must be followed. Reference Long Line Set section in the 1&0 [ ] Designates Metric Conversions O Refrigerant Line Size Information (con't.) R-410A System Capacity Model Vapor Line Connection Size (Inch I.D.) [mm] Vapor Line Size (Inch O.D.) [mm] Chart ZirnTable To - Feet 1 341 0 [m] 25 [7.62] 50 [15.24] 175 [22.86] 100 [30.48] 1125 [45.72] 7200 [60.96] 225 [68.58] 250 [76.20] 275 [83.82] 1300 [91.441 24 3/4"[19.06] 5/8 [15.88] 0.99 0.99 0.98 0.97 0.96 0.93 0.92 0.91 0.9 0.9 3/4 [19.05] 1.00 1.00 1.00 0.99 0.99 0.98 0.98 0.98 0.97 0.97 7/8 [22.23] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 1-1/8 [28.581 N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 36 3/4"[19.06] 5/8 [15.88] 0.98 0.96 0.94 0.92 0.9 0.85 0.84 0.83 0.84 0.82 3/4 [19.05] 1.00 0.99 0.98 0.98 0.97 0.94 0.94 0.93 0.93 0.92 7/8 [22.23] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 1-1/8 [28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 48 3/4" [19.061 5/8 [15.88] 0.99 0.98 0.98 0.96 0.95 0.92 0.91 0.9 0.89 0.88 3/4 [19.051 0.98 0.94 0.91 0.89 0.87 0.81 0.8 0.82 0.81 0.83 7/8 [22.23] 1.00 0.99 0.99 0.98 0.98 0.97 0.97 0.96 0.95 0.95 1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 1-1/8 [28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 60 3/4" [19.06] 5/8 [15.88] 0.99 0.98 0.96 0.95 0.94 N/R N/R N/R N/R N/R 3/4 [19.05] 0.97 0.93 0.89 0.87 0.84 N/R N/R N/R N/R N/R 7/8 [22.23] 1.00 0.99 0.99 0.98 0.98 N/R N/R N/R N/R N/R 1 [25.4] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R 1 1/8 [28.58] N/R N/R N/R N/R N/R N/R N/R N/R N/R N/R NOTES: v N/R =Application not recommended. All calculations assume a 3/8" liquid line n O M [ ] Designates Metric Conversions a� ru z O CE, mCD m m �* VI r m Performance Data @ AHRI Standard Conditions — Heat Pump High Sales Volume Tested Combination (HSVTC) Outdoor Unit Air Handler Total Capacity BTU/H [kW] Net Sensible BTU/H [kW] Net Latent BTU/H [kW] SEER EER Indoor CFM [L/s] 47 Degree Heating Capacity BTU/H [kW] 47 Degree COP 17 Degree Heating Capacity BTU/H [kW] 17 Degree COP Region IV HSPF AHRI# UP2024AJV RHMV2421HEAC 24000 [7.0] 18500 [5.4] 5500 [1.6] 20.5 14.5 850 [401.21 19500 [5.7] 4.6 28000 [8.2] 2.4 13 8950569 UP2048AJV RHMV6021SEAC 46500 [13.6] 36200 [10.6] 10300 [3.0] 20 12.5 1650 [778.71 35600 [10.4] 4.5 45500 [13.3] 2.4 13 8950570 [ ] Designates Metric Conversions '0CD , 0 E. 3 m CD 7 (n N 0 v v Guide Specifications UP20 Series GUIDE SPECIFICATIONS General System Description Outdoor -mounted, air-cooled, split -system heat pump unit suit- able for ground or rooftop installation. Unit consists of a hermetic compressor, composite basepan, an air-cooled coil, propeller - type condenser fan, suction and liquid line service valve, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a coil unit. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c-UL-us approval. — Unit cabinet will be capable of withstanding ASTM 13117 1000- hr salt spray test. — Air-cooled condenser coils will be leak tested at 150 psig and pressure tested at 550 psig. — Unit constructed in IS09001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer's recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. Products Equipment Factory assembled, single piece, air-cooled heat pump unit. Con- tained within the unit enclosure is all factory wiring, piping, con- trols, compressor, refrigerant charge R-410A, and special fea- tures required prior to field start-up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonder- ized, and coated with a powder coat paint. — All units constructed with louver coil protection and corner post. Louver can be removed by removing one fastener per louver panel. Your Local Ruud Contractor NWHVAC Service 14004 NE 82nd Ave Vancouver, WA 98662 phone:360-576-9679 f ax: 360-576-1588 Email: office@nwhvac.net AIR-COOLED, SPLIT -SYSTEM HEAT PUMP U P20 1-1/2 TO 5 NOMINAL TONS Fans — Condenser fan will be direct -drive propeller type, discharging air upward. — Condenser fan motors will be totally enclosed, 1-phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. — Compressor will be Copeland fully variable speed. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes. Refrigeration Components — Refrigeration circuit components will include liquid -line shutoff valve with sweat connections, vapor -line shutoff valve with sweat connections, system charge of R-410A refrigerant, and compressor oil. — Unit will be equipped with filter drier for R-410A refrigerant for field installation. Operating Characteristics — The capacity of the unit will meet or exceed Btuh at a suction temperature of °F/°C. The power consumption at full load will not exceed kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of Btuh or greater at conditions of CFM entering air temperature at the evap- orator at °F/°C wet bulb and °F/°C dry bulb, and air entering the unit at °F/°C. — The system will have a SEER of Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Nominal unit electrical characteristics will be v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of v to V. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Limited Warranty UP20 Series GENERAL TERMS OF LIMITED WARRANTY* Ruud will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Unit Replacement (Registration Required) ...............................Ten (10) Years Parts............................................................Ten (10) Years Notes UP20 Series In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. Ruud Heating, Cooling & Water Heating • P.O. Box 17010 Ruud Canada • 125 Edgeware Road, Unit 1 Fort Smith, Arkansas 72917 • www.ruud.com Brampton, Ontario • L6Y OP5 PRINTED IN U.S.A. 3/16 QG FORM NO. P22-81 1