Loading...
APPROVED FIR2022-0112+Fire_Sprinkler_Plan+1.16.2023_12.58.45_PM+3316531LEGEND EXISTING PIPE NEW PIPE CAPPED OFF PIPE CPVC EXISTING QR UPRIGHT EXISTING QR PENDENT O NEW QR PENDENT NEW MRI PENDENT � NEW FULL HEIGHT WALL SCOPE OF WORK 1. REPLACE 4 EXISTING UPRIGHT SPRINKLERS FOR PENDANTS IN THE CONTROL ROOM AND STRETCHER VESTIBULE. CAP OFF AND ABANDON EXISTING PIPE IN PLACE IN NON COMBUSTIBLE SPACE ABOVE THE MRI ENCLOSURE AND INSTALL CPVC WITHIN MRI ENCLOSURE WITH 4 NEW PENDENT SPRINKLERS TO COMPLY WITH TENET IMPROVEMENT. 2. MAX SPACING 225 SQ FT FOR LIGHT HAZARD -HOSPITAL 3. INSTALL NEW QR PENDENT SPRINKLER HEADS. 4. UNOBSTRUCTED NON COMBUSTIBLE CONSTRUCTION. 5. ONLY NON FERROUS MATERIALS ALLOWED IN MRI ENCLOSURE. GENERAL NOTES 1. ALL DESIGN AND INSTALLATION IS IN ACCORDANCE WITH NFPA 13, 2016 AND THE CITY OF EDMONDS. 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND FM LISTED. 3. BLACK SCHEDULE 40 FOR 1" SPRINKLER PIPE AND SCHEDULE 10 FOR ALL 1-1/4" - 4" SPRINKLER PIPE OUTSIDE MRI ENCLOSURE AND TEMPORARY PROTECTION. CPVC INSIDE MRI ENCLOSURE ONLY. 4. 1" THREADED PIPE AND FITTINGS AND 1-1/4" -6" GROOVED PIPE AND FITTINGS OUTSIDE OF MRI ENCLOSURE AND CPVC FITTINGS WITHIN THE MRI ENCLOSURE. 5. PIPING DIMENSIONS ARE CUT LENGTH. 6. HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA 13 2016. 7. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA 13 2016. 8. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT PIPE FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM THAT IS NOT PROTECTED BY HEAT TRACE. KEY PLAN AREA OF V1 .,,. LEVEL `SITE MAP 4111111=01"TA MR VICINI mru- Su9iulaere Urt [ TY MAP SPRINKLER WAVEGUIDE 8"x8" SST PLATE SST WAVE GUIDE NPT THREAD (BY IMEDCO) INTERIOR EXTERIOR SPRINKLER NETWORK SPRK. NETWORK (BY OTHERS) DIELECTRIC NPT THREAD SWEDISH EDMONDS MRI BUILDOUT — o I I 10 1 I I W/S r , - ARPIN P K 1 OVERHEAD PIPING PLAN I SCALE: 1 /4 = 1 -❑ IMEDCO PENETRATION PLATE (1219x6l0) (BY OTHERS) a► o `~ Y�WC fi 10 flrANS -----------------t------I— rrr —1— r o I l a II ®II .. or I . cicxt 40 ®II ® 0 40 I 11 111 I I II II w k �, 1.4C II Oil 0 ® 04"X10A I f I I I I t I Aid W a °C ^ I a � � � a � I� T •�• ® ® I � I I a < a 4a csC, e 8 ® ® I I I I ria L J Ex rJA I I I I I ♦ + I e ; EXTERIOR VIEW I 1 I I I t 11. I 1 I I I 1 I l e J LJ I I, L- — — — — ————— — — — — — � 0 r DECK @ 13-0" AFF CAPPED BRANCH LINES @ 12'-1" AFF SPRINKLER WAVE GUIDE @ 9'-5 1/2"AFF ACT @ 9"1 AFF Approved DFM Chris Burt South County Fire Date: 01 /24/2023 01-24-2023 PLAN REVIEW NOTE: APPROVED DFM BURT STAINLESS STEEL SAMMYSCREW STAINLESS STEELATR� COPPER RING/ DROP CEILING \ i / WOOD JOISTS FIRE SPRINKLER USE NON FERROUS MATERIALS ONLY NSF INTERNATIONAL APPROVED FOR USE WITH POTABLE WATER CPVC HANGER DETAIL N.T.S. / SAMMY SIDEWINDER SCREW JOIST STAINLESS STEEL ATR A COPPER, ALUMINUM OR SST RING BRANCHLINE PIPING BRANCHLINE RESTRAINT DETAIL N.T.S. WOOD JOIST PIPE HANGER DROP CEILING — CPVC DROP FIRE SPRINKLER CPVC DROP DETAIL CURE TIMES WITH ONE STEP SOLVENT CEMENT 200 psi (MAAMUM) TEST PRESSURE PIPE SIZE Ambient Temperature During Cure Period inches 60eF to 120°F 40°F to 59°F 0°F to 39°F 3/4" 45 min. 1.5 hr. 24 hr. 1" 45 min. 1.5 hr. 24 hr. 1'/a" 1.5 hr. 16 hr. 120 hr. 1W. 1.5 hr. 16 hr. 120 hr. 2" 6 hr. 36 hr. See Note 1 2'/" 8 hr. 72 hr. See Note 1 See Note 1 3" 8 hr. 72 hr. Note 1 For these sizes, the solvent cement can be applied at temperatures below 32T however, the sprinider system temperature must be raised to a temperature of 32'F or above and allowed to cure per the above recommendations prior to pressJre testing. 2x1 %4"x9Y2" LVL BEAMS 3Y2" INSULATION " COMPRESSED INSULATION 3Y2 PY2' FR PLYWOOD W24X55 W14X22 �3�4' FR PLYWOOD CON C. ±0.00 CY co I Z I J E CZ Cn Cn f ! ®:; PPYIMEDCO; ao mn 0000 �� _ CL ^II m° rid III I'lll"I "14�SI1L -II'I �-+-J i L o VV) 4'-71/$„ C INT. FRAMING W it I CTR +Ya" RM. F +61 0.0 Ln 1'-113w, M D PR HATCH i N CPVC PIPING @ 9'-5 1/2" AFF ELEVATION VIEW Eiir iviRi I 00M SCALE: NTS F I R2022-0112 w z - w •• O0 _ w NZ Q �U 77Z0 N — E Q (`7 LL W �16.zQ U0 Q F W O �` p 6, •� Cn Ud ccv 0 a�No-zQ Y-rl O w J 0 Wc. W ° N �I o�70�oZ,,, 1- Q�NO�c�'�)U �w frl h.4 o ui-OcoJ rno3-� 60 0000 d -� JH 0000 U Z 0000 4 00 0000 U w 0000 0— 000o 2:7 QLu �Q off U ii 1 a;ea w n 1 1 £zOz/zl•/I• 1 a 1 W M x u 1 1 V N 1 T 1 ZIU 1 Q a J 1 1 F � Z on Y I y 1 1 i o i LL a 1 O 1 Z F O N> 1 1 V rn Z 1 Q V 1 LL W p 0 1 1 W Q.M�yLL 1 Oy! m�00 a=+1 1 E " 00 C 1 LL Ot.IU0 21 1 N 1 �-----------------� J Z 0 W W OY Z K CIO iE �vao A�� N E LL N O m`U U0� C o J L a) C L_ N 0 I-T x ,N Z J � In a o � t, Z `" Z a Dim MNW Waa Wwrn 0 N�tn L �x3 W W —no ; o L�Z W of a m�� F ? W a NNW DQ mNN 3 C SYMBOLS 4 2-WAY Eq BRACE 4-WAY Eq BRACE BRANCH LINE RESTRAINT \J. 7� HANGER LOCATION REVISION CENTERLINE A.F.F. *o0<� Jan 17 2023 *(}�, PIPE C/L TO B.O.D. CITY OF EDMONDS (0)POINT ULIC REFERENCE DEVELOPMENT SERVICES DEPARTMENT --3 FLEXIBLE COUPLING DATE : JAN 1 1, 2023 �7 1 13 4 S SCALE AS NOTE DRAWN BY: AG11= JOB NO.: 25SSIi 1-011 SHEET NO. SCALE — 1 /4" _ 1 FP 1.00 KEY PLAN AREA OF WORK SITE LOCATION y0 V LEGEND EXISTING PIPE NEW PIPE DEMO PIPE PIPE BEING RAISED EXISTING QR U PR IC EXISTING QR PEN D NEW QR UPRIGHT REPLACED QR UPR NEW FULL HEIGHT SITE MAP VICINITY MAP SWEDISH EDMONDS Mill BUILDOUT INSTALL PLAN RAISED BRANCH LINES @ 121-1 & 1214 BOTTOM OF BEAM @ 111-0 SCOPE OF WORK 1. RAISE BRANCH LINES UP TO ALLOW FOR CONSTRUCTION OF MRI ENCLOSURE. REPLACE 10 EXISTING UPRIGHTS WITH NEW QR UPRIGHTS AND ADD 4 MORE TO PROVIDE TEMPORARY COVERAGE. 2. MAX SPACING 225 SQ FT FOR LIGHT HAZARD - HOSPITAL 3. INSTALL NEW QR UPRIGHT SPRINKLER HEADS. 4. UNOBSTRUCTED NON COMBUSTIBLE CONSTRUCTION. GENERAL NOTES 1. ALL DESIGN AND INSTALLATION IS IN ACCORDANCE WITH NFPA 13, 2016 AND THE CITY OF EDMONDS. 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND FM LISTED. 3. BLACK SCHEDULE 40 FOR 1" SPRINKLER PIPE AND SCHEDULE 10 FOR ALL 1-1/4" - 4" SPRINKLER PIPE. 4. 1" THREADED PIPE AND FITTINGS AND 1-1/4" —611 GROOVED PIPE AND FITTINGS. 5. PIPING DIMENSIONS ARE CUT LENGTH. 6. HANGERS AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA 13 2016. 7. JOINING OF PIPE AND FITTINGS, THREADED AND WELDED SHALL BE IN ACCORDANCE WITH NFPA 13 2016. 8. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT PIPE FROM FREEZING IN AREAS PROTECTED BY WET PIPE SPRINKLER SYSTEM THAT IS NOT PROTECTED BY HEAT TRACE. 3000111 NORMAL WE13HT CONCRETE • • d ;`: a�a s a �1/2" OR 318" 3/9"ATR for 1' 4" PIPE 1/2" ATR for 6" & T PIPE 1 1 -8, RING I I #05C- HILTI HDI-P TZ DROP IN ANCHOR RETAINING BEAM CLAMP c TLOCKJNGTHREAD/ o GUNNEUTIONe RING FIG. IOR ,RETAINING f STRAP PI E TOP BEAM CLAMP CONCRETE ERICO ATR GWIVEL 3/B' ATR IICO EL ATTACHMENT 1'-7' Soo ® 7'T ERICO WIVI ERICO BL ATTACHM .NT ATTACHMENT TO CONC #BLR- BRANCHLINE RESTRAINT DECK @ 13-0 EXISTING BRANCH LINES @ 10--8 DRAIN @ 61-01' REVISIO Jan 17 2023 CITY OF EDMONDS DEVELOPMENT SERVICE DEPARTMENT O qr Iq II LL LL 00 0 E LO LO t N LLNN CO m °L O c to o L � co .L CL ALL 4923 L L L 0 In In <.i N LL Y 00 zoo L_ U l0 �55 E ISOMETRIC VIEW SCALE: WTS ELEVATION VIEW SCALE: NTS 2 1 0 4 8 I I I I SCALE - 1 /40 = 1'-O"