Loading...
APPROVED BLD PLN BLD2020-1292+ARCHITECTUAL PLANS+1.29.2021_7.23.51_PM+2023738MUELLER ADDITION 200th St SW w 6 200ih S[ SW N J _ � D m f° � � 200th St SW D SITE �20124 81st Avenue West w > 203rd St SW VICINITY MAP NTS u ABBREVIATIONS /C XIMUM FF UM L LK LK BLOCKING BUILT-UP L ENT R LIN LG CEILING OMP COMPOSITION ONC ONCRETE ONT ONTINUOUS ONTR ONTRACTOR PT ARPET N S NG S DOOR WB ARCHITECTURAL SYMBOLS X� DETAIL X� SHEET N0. X � SECTION X X.X � SHEET N0. X.X DETAIL REFERENCE BUIEDING SECTION REFERENCE FEET &INCHES IN WIDTH FEET &INCHES IN HEIGHT OPERATION WINDOW NOMENCLATURE ARC H TECTU RAC NOTES: OWNER JAKE MUELLER 1 20124 81ST AVE W EDMONDS, WA 98026 2 3 DESIGNER NEW WORLD DESIGN, LLC JOHN RODRIGUEZ 4 LAKEWOOD, WA VOICE: 253-271-8501 EMAIL: JOHN@NWD-WA.COM 5 STRUCTURAL DS ENGINEERING DONG SHIN, P.E., S.E. 3121 147TH PL SE MILL CREEK, WA. 98012 VOICE: 425-338-4776 EMAIL: DSHIN@ENGINEER.COM DRAWING INDEX PROJECT TEAM 7 8. 90 11 12 13 14 15 m PROPOSED ELEVATION PROVIDE SLEEVES FOR DUCT AND PIPE OPENINGS IN CONCRETE WALLS, GROUT HOLES SMOOTH, PAINT TO MATCH ADJACENT SURFACES. GYPSUM WALL BOARD (GWB) IN TOILET/SHOWER ROOMS SHALL BE WATER RESISTANT. DO NOT INSTALL WATER RESISTANT GWB ON CEILING OR OVER VAPOR BARRIER ALL WOOD MEMBERS IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED AND WOOD SHIMS, ROUGH BUCKS, NAILERS AND BLOCKING IN ENCLOSED SPACES, BELOW GRADE OR OTHERWISE SUBJECT TO "DRY ROT" SHALL BE PRESSURE TREATED. CONTRACTOR SHALL PROVIDE FLOOR/CEILING AND ATTIC DRAFTSTOPS PER CODE. CONCEALED INTERSTITIAL FLOOR/CEILING AREA BETWEEN DRAFTSTOPS NOT TO EXCEED 1,000 SF AND SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. CONTRACTOR SHALL PROVIDE FIRESTOPPING PER CODE. PROVIDE 2" NOMINAL SOLID BLOCKING OR MINERAL FIBER BATT SECURELY FASTENED IN PLACE, TO COMPLETELY FILL CAVITIES TO BE FIREBLOCKED. CONCEALED SPACES BETWEEN STUDS, INCLUDING FURRED SPACES SHALL NOT EXCEED 10 FT IN LENGTH VERTICALLY AND HORIZONTALLY. OPENINGS FOR DUCT AND PIPE PENETRATIONS, CHASES AND WALL INTERSECTION WITH CEILING FLOOR AND STAIR STRINGERS SHALL BE FIREBLOCKED. UNLESS OTHERWISE NOTED IN THE DRAWINGS; NAILING SHALL BE GALVANIZED WHERE IN CONTACT WITH TREATED WOOD, AND SHALL BE STAINLESS STEEL WHERE IN CONTACT WITH CEDAR SIDING AND DECKING. ALL GLASS AND GLAZING SHALL COMPLY WITH THE CURRENT CODE AND U.S. CONSUMER PRODUCT SAFETY COMMISSION SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS. ALL SMOKE DETECTORS SHALL BE HARDWIRED AND INTERCONNECTED. ALL INSULATION SHALL BE IN CONFORMANCE WITH CURRENT CODE. ALL EXPOSED GWB TO HAVE METAL EDGES AT ALL CORNERS AND WALL INTERSECTIONS, ALL EXTERIOR DOORS AND WINDOWS SHALL BE WEATHER-STRIPPED, CAULKED AND SEALED TO MEET THE LOCAL CODE REQUIREMENTS AND ASTM E283-763. VAPOR BARRIERS SHALL BE INSTALLED ON THE WARM SIDE OF ALL WALLS, FLOORS AND CEILINGS. HOT WATER HEATERS SHALL COMPLY WITH THE REQUIREMENTS OF ASHRAE AND SHALL BE VENTED TO THE EXTERIOR. FINISH GRADES TO BE 6" MIN. BELOW WOOD SIDING AND 8" MIN. BELOW TOP OF FOUNDATION WALL. PROVIDE ASPHALTIC WATERPROOF MEMBRANE AT FOUNDATION WALLS BEFORE BACKFILLING. PROVIDE GRAVEL AND PERFORATED DRAIN PIPE, SEE STRUCTURAL FOR ADDITIONAL INFORMATION. PROVIDE 18" MIN. CRAWL SPACE UNDER WOOD JOISTS AND 12" UNDER WOOD GIRDERS. PROVIDE 6 MILLIMETER VAPOR BARRIER IN CRAWL SPACE AND UNDER SLABS (U.N.O.) GENERAL NOTES: 1. CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED BY LOCAL AND STATE GOVERNING AUTHORITIES. 2. REPETITIVE FEATURES NOT NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. IF CERTAIN FEATURES ARE NOT FULLY SHOWN OR CALLED FOR ON THE DRAWINGS THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR A0.1 COVER SHEET CONDITIONS THAT ARE SHOWN OR CALLED FOR. A0.2 GENERAL NOTES 3. CONTRACTOR IS RESPONSIBLE FOR BRACING, SHORING AND STORM A1.0 ELEVATIONS WATER CONTROL NECESSARY FOR SAFETY, ENVIRONMENTAL PROTECTIONS A2.0 DEMOLITION PLANS AND COMPLETION OF THE WORK. A2.1 PROPOSED FLOOR PLANS 4. DIMENSIONS ARE TO THE FACE OF STUD AT WALLS, FACE OF A2.2 PARTIAL BUILDING SECTIONS AND FOUNDATION PLAN CONCRETE AT FOUNDATION WALLS, TO THE CENTER OF COLUMNS AND A2.3 ROOF PLAN OPENINGS AND TO THE TOP OF SLAB OR PLYWOOD SUBFLOOR U.N.O. A5.0 DETAILS A5.1 DETAILS II 5. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN APPROVED BY THE OWNERS REPRESENTATIVE. ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS AND SAMPLE. OWNERS REPRESENTATIVE SHALL DETERMINE WHICH PORTIONS OF THE WORK SHALL REQUIRE SHOP DRAWINGS SUBMITTAL. BU �D NG CODE NOTES: CARPENTRY 1. WOOD FRAMING MEMBERS GRADES ARE AS FOLLOWS U.N.O. ON THE PLANS: POSTS, BEAMS, HEADERS, JOISTS, RAFTERS - N0. 2 DOUGLAS FIR; PLATES BLOCKING, BRIDGING, ETC - N0. 3 HEM -FIR; STUDS - STUD GRADE HEM -FIR N0. 2 2. ALL FRAMING MEMBERS SHALL BE KILN DRIED TO A 19% MADM MOISTURE CONTENT. GLAZING: 1. ALL EXTERIOR WINDOWS TO BE DOUBLE GLAZED WITH A U-VALUE OF 0.30 OR BETTER 2. SKYLIGHT GLAZING SHALL BE CONSTRUCTED OF LAMINATED GLASS WITH A MIN 30 MIL POLYVINYL BUTYRAL (OR EQUIVALENT) INTERLAYER WIRED GLASS, APPROVED PLASTIC MATERIALS MEETING THE REQUIRMENTS OF THE IBC, HEAT -STRENGTHENED GLASS OF FULLY TEMPERED GLASS. VENTILATION: 1. PROVIDE COMBUSTION AIR VENTS TO ALL FIREPLACES AND ANY HEATING APPLIANCES USING OPEN FLAME. 2. BATHROOMS AND TOILET/SHOWER COMPARTMENTS ARE TO BE VENTED WITH A 50 CFM FAN EXHAUSTED TO THE OUTSIDE. RANGE HOODS ARE TO BE VENTED WITH 100 CFM . 3. ATTIC SPACE TO HAVE A MINIMUM 1" AIRSPACE BETWEEN INSULATION AND ROOF SHEATHING PER BUILDING CODE. PROVIDE RIDGE VENTS AND LOW VENTS IN BLOCKING, AS REQUIRED. CLOTHES DRYER: 1. THE CLOTHES DRYER IS TO BE VENTED TO THE OUTSIDE AND SHALL BE EQUIPPED WITH ABACK -DRAFT DAMPER. DUCTS SHALL NOT BE CONNECTED OR INSTALLED WITH SHEET METAL SCREWS OR OTHER FASTENERS WHICH WILL OBSTRUCT THE FLOW. SMOKE DETECTORS: SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: 1. IN EACH SLEEPING ROOM 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. WHEN MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHIN AN INDIVIDUAL DWELLING UNIT THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT. ATTIC ACCESS: ACCESS SHALL BE IN A HALLWAY OR READILY ACCESSIBLE LOCATION NO LESS THAN 22"x30" OPENING WITH A MIN. OF 30" UNOBSTRUCTED HEAD ROOM IN THE ATTIC. PRESCRIPTIVE REQUIREMENTS PER TABLE WSEC 402.1.1 GLAZING U-FACTOR VERTICAL 0.30 SKYLIGHT 0.50 DOOR U-FACTOR 0.30 CEILINGS R-49 WALLS ABOVE GRADE R-21 FLOORS R-30 SLAB ON GRADE R-10 (2'-0") (HEATED SPACE ONLY) r----------■�-------� I Hardware and fasteners in contact with preservative -treated wood shall be of ■ ' hot -dipped zinc galvanized steel, I stainless steel, silicon bronze or copper. .In the absence of manufacturer's recommendations Ia minimum of ASTM A 653 type G185 zinc -coated I galvanized steel, or equivalent, shall be used. ■ LIRC R317.3.1 IBC 2304.10.5.1 I ------------------- PROJECT DESCRIPTION REMODEL/ADDITION TO AN EXISTING SINGLE STORY HOME. REMOVAL OF AND RELOCATION OF BEARING AND NON -BEARING WALES. ADDITION OF BEDROOM, BATHROOM, MECHANICAL ROOM, AND EXPANDED KITCHEN AND DECK AREAS. PROJECT INFORMATION SITE ADDRESS: 20124 81 ST AVE W EDMONDS, WA 98026 TAX PARCEE N0. 00431200002800 CODES 2015 IRC 2015 WA. STATE ENERGY CODE (WAC 51-11) APPROVED BY PLANNING �� Feb 10 2021 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE CITY OF EDMONDS BUILDING DIVISION APPROVED PLAN City Of Edmonds Building Department Work ADDITION Address 20124 81 ST AVE W Owner MUELLER Approved Date 02/18/2021 Building Official ����� ���� ���� Permit Number BLD2020-1292 ew ��or�� ����� PHONE 253.271.8501 NEW WORLDDESIGNLLC.COM U J J z c� w 0 J >� >> W Z 0 N O N O �L Q 0 U These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TITLE MUELLER ADDITION PROJECT ADDRESS 20124 81ST AVE W EDMONDS, WA 98026 0 AFP OCT 27, 2020 COVER SHEET DRAWN J. RODRIGUEZ PROJECT # 20-111 SHEET SCALE AS NOTED SHEET NUMBER A-0.1 RESUB Feb 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 2015 IRC R403.1.6 FOUNDATION ANCHORAGE: 2015 WSEC SECTION R403: 2015 WSEC SECTION 404: WOOD SOLE PLATES AT ALL EXTERIOR WALLS ON MONOLITHIC SLABS, WOOD SOLE PLATES OF BRACED WALL PANELS AT BUILDING INTERIORS ON MONOLITHIC SLABS AND ALL WOOD SILL PLATES SHALL BE ANCHORED TO THE FOUNDATION WITH ANCHOR BOLTS SPACED A MAXIMUM OF 6 FEET ON CENTER. BOLTS SHALL BE AT LEAST 1/2 INCH IN DIAMETER AND SHALL EXTEND A MINIMUM OF 7 INCHES INTO CONCRETE OR GROUTED CELLS OF CONCRETE MASONRY UNITS. A NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PLATE SECTION WITH ONE BOLT LOCATED NOT MORE THAN 12 INCHES OR LESS THAN SEVEN BOLT DIAMETERS FROM EACH END OF THE PLATE SECTION. INTERIOR BEARING WALL SOLE PLATES ON MONOLITHIC SLAB FOUNDATION THAT ARE NOT PART OF A BRACED WALL PANEL SHALL BE POSITIVELY ANCHORED WITH APPROVED FASTENERS. CONCRETE NOTE: CONCRETE SHALL HAVE MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 3000' f� , AS SHOWN IN TABLE 402.2. CONCRETE SUBJECT TO MODERATE OR SEVERE WEATHERING AS INDICATED IN TABLE R301.2 (1) SHALL BE AIR ENTRAINED AS SPECIFIED IN TABLE 402.2. FLASHING NOTE 2015 IRC R703.4: APPROVED CORROSION -RESISTANT FLASHING SHALL BE APPLIED SHINGLE -FASHION IN A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. SELF ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711. FLUID -APPLIED MEMBRANES USED AS FLASHING IN EXTERIOR WALLS SHALL COMPLY WITH AAMA 714. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION -RESISTANT FLASHINGS SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS: 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTIVE BARRIER COMPLYING WITH SECTION 703.2 FOR SUBSEQUENT DRAINAGE. 1.1. THE FENESTRACTION MANUFACTURERS INSTALLATION AND FLASHING INSTRUCTIONS, OR FOR APPLICATIONS NOT ADDRESED IN THE FENESTRACTION NAUFACTURERS INSTRUCTIONS, IN ACCORDANCE WITH THE FLASHING MANUFACTURERS INSTRUCTIONS. WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED, PAN FLASHING SHALL BE INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER -RESISTIVE BARRIER FOR SUBSEQUENET DRAINAGE. OPENINGS USING PAN FLASHING SHALL INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES. 1.2. IN ACCORDANCE WITH THE FLASHING DESIGN OR METHOD OF A REGISTERED DESIGN PROFESSIONAL 1.3. IN ACCORDANCE WITH OTHER APPROVED METHODS. 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR METAL COPINGS AND SILLS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. 5. WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD -FRAME CONSTRUCTION. 6. AT WALL AND ROOF INTERSECTIONS. 7. AT BUILT-IN GUTTERS. R401.3 CERTIFICATE (MANDATORY). A PERMANENT CERTIFICATE SHALL BE COMPLETED BY THE BUILDER OR REGISTERED DESIGN PROFESSIONAL AND POSTED ON A WALL IN THE SPACE WHERE THE FURNACE IS LOCATED, A UTILITY ROOM, OR AN APPROVED LOCATION INSIDE THE BUILDING. WHEN LOCATED ON AN ELECTRICAL PANEL, THE CERTIFICATE SHALL NOT COVER OR OBSTRUCT THE VISIBILITY OF THE CIRCUIT DIRECTORY LABEL, SERVICE DISCONNECT LABEL, OR OTHER REQUIRED LABELS. THE CERTIFICATE SHALL LIST THE PREDOMINANT R-VALUES OF INSULATION INSTALLED IN OR ON CEILING/ROOF, WALLS, FOUNDATION (SLAB, BELOW -GRADE WALL, AND/OR FLOOR) AND DUCTS OUTSIDE CONDITIONED SPACES; U-FACTORS FOR FENESTRATION AND THE SOLAR HEAT GAIN COEFFICIENT (SHGC) OF FENESTRATION, AND THE RESULTS FROM ANY REQUIRED DUCT SYSTEM AND BUILDING ENVELOPE AIR LEAKAGE TESTING DONE ON THE BUILDING. WHERE THERE IS MORE THAN ONE VALUE FOR EACH COMPONENT, THE CERTIFICATE SHALL LIST THE VALUE COVERING THE LARGEST AREA. THE CERTIFICATE SHALL LIST THE TYPES AND EFFICIENCIES OF HEATING, COOLING AND SERVICE WATER HEATING EQUIPMENT. WHERE A GAS -FIRED UNVENTED ROOM HEATER, ELECTRIC FURNACE, OR BASEBOARD ELECTRIC HEATER IS INSTALLED IN THE RESIDENCE, THE CERTIFICATE SHALL LIST "GAS -FIRED UNVENTED ROOM HEATER," "ELECTRIC FURNACE" OR "BASEBOARD ELECTRIC HEATER," AS APPROPRIATE. AN EFFICIENCY SHALL NOT BE LISTED FOR GAS -FIRED UNVENTED ROOM HEATERS, ELECTRIC FURNACES OR ELECTRIC BASEBOARD HEATERS. IRC M1502.5 PROTECTION REQUIRED: PROTECTIVE SHIELD PLATES SHALL BE PLACED WHERE NAILS OR SCREWS FROM FINISH OR OTHER WORK ARE LIKELY TO PENETRATE THE CLOTHES DRYER EXHAUST DUCT. SHIELD PLATES SHALL BE PLACED ON THE FINISHED FACE OF ALL FRAMING MEMBERS WHERE THERE IS LESS THAN 1 1/4" BETWEEN THE DUCT AND THE FINISHED FACE OF THE FRAMING MEMBERS. PROTECTIVE SHIELD PLATES SHALL BE CONSTRUCTED OF STEEL, SHALL HAVE A MINIMUM THICKNESS OF 0.062 INCH AND SHALL EXTEND NOT LESS THAN 2 INCHES ABOVE SOLE PLATES AND BELOW TOP PLATES. 2015 IRC M1503.1 GENERAL: RANGE HOODS SHALL DISCHARGE TO THE OUTDOORS THROUGH ASINGLE-WALL DUCT. THE DUCT SERVING THE HOOD SHALL HAVE A SMOOTH INTERIOR SURFACE, SHALL BE AIR TIGHT AND SHALL BE EQUIPPED WITH A BACKDRAFT DAMPER AND SHALL BE INDEPENDENT OF ALL OTHER EXHAUST SYSTEMS. DUCTS SERVING RANGE HOODS SHALL NOT TERMINATE IN AN ATTIC OR CRAWL SPACE OR AREAS INSIDE THE BUILDING. EXCEPTION: WHERE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND WHERE MECHANICAL OR NATURAL VENTILATION IS OTHERWISE PROVIDED, LISTED AND LABELED DUCTLESS RANGE HOODS SHALL NOT BE REQUIRED TO DISCHARGE TO THE OUTDOORS. 2015 IRC M1601.1 DUCT DESIGN: DUCT SYSTEMS SERVING HEATING, COOLING, AND VENTILATION EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS SECTION AND ACCA MANUAL D, THE APPLIANCE MANUFACTURERES INSTALLATION INSTRUCTIONS OR OTHER APPROVED METHODS. IRC M1502.4.6 WHERE THE DRYER EXHAUST DUCT EQUIVALENT LENGTH EXCEEDS 35 FEET, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A PERMANENT LABEL OR TAG. THE TAG SHALL BE LOCATED WITHIN 6 FEET OF THE EXHAUST DUCT CONNECTION. R403.1.1 PROGRAMMABLE THERMOSTAT. WHERE THE PRIMARY HEATING SYSTEM IS A FORCED -AIR FURNACE, AT LEAST ONE THERMOSTAT PER DWELLING UNIT SHALL BE CAPABLE OF CONTROLLING THE HEATING AND COOLING SYSTEM ON A DAILY SCHEDULE TO MAINTAIN DIFFERENT TEMPERATURE SET POINTS AT DIFFERENT TIMES OF THE DAY. THE THERMOSTAT SHALL ALLOW FOR, AT A MINIMUM, A 5-2 PROGRAMMABLE SCHEDULE (WEEKDAYS/WEEKENDS) AND BE CAPABLE OF PROVIDING AT LEAST TWO PROGRAMMABLE SETBACK PERIODS PER DAY. THIS THERMOSTAT SHALL INCLUDE THE CAPABILITY TO SET BACK OR TEMPORARILY OPERATE THE SYSTEM TO MAINTAIN ZONE TEMPERATURES DOWN TO 55°F (13°C) OR UP TO 85°F (29°C). THE THERMOSTAT SHALL INITIALLY BE PROGRAMMED BY THE MANUFACTURER WITH A HEATING TEMPERATURE SET POINT NO HIGHER THAN 70°F (21 °C) AND A COOLING TEMPERATURE SET POINT NO LOWER THAN 78°F (26°C). THE THERMOSTAT AND/OR CONTROL SYSTEM SHALL HAVE AN ADJUSTABLE DEADBAND OF NOT LESS THAN 10°F. EXCEPTIONS: 1. SYSTEMS CONTROLLED BY AN OCCUPANT SENSOR THAT IS CAPABLE OF SHUTTING THE SYSTEM OFF WHEN NO OCCUPANT IS SENSED FOR A PERIOD OF UP TO 30 MINUTES. 2. SYSTEMS CONTROLLED SOLELY BY A MANUALLY OPERATED TIMER CAPABLE OF OPERATING THE SYSTEM FOR NO MORE THAN TWO HOURS. R403.3.3 DUCT TESTING (MANDATORY). DUCTS SHALL BE LEAK TESTED IN ACCORDANCE WITH WSU RS-33, USING THE MAXIMUM DUCT LEAKAGE RATES SPECIFIED. EXCEPTION: THE TOTAL LEAKAGE TEST OR LEAKAGE TO THE OUTDOORS IS NOT REQUIRED FOR DUCTS AND AIR HANDLERS LOCATED ENTIRELY WITHIN THE BUILDING THERMAL ENVELOPE. FOR FORCED AIR DUCTS, A MAXIMUM OF 10 LINEAR FEET OF RETURN DUCTS AND 5 LINEAR FEET OF SUPPLY DUCTS MAY BE LOCATED OUTSIDE THE CONDITIONED SPACE. ALL METALLIC DUCTS LOCATED OUTSIDE THE CONDITIONED SPACE MUST HAVE BOTH TRANSVERSE AND LONGITUDINAL JOINTS SEALED WITH MASTIC. IF FLEX DUCTS ARE USED, THEY CANNOT CONTAIN SPLICES. FLEX DUCT CONNECTIONS MUST BE MADE WITH NYLON STRAPS AND INSTALLED USING A PLASTIC STRAPPING TENSIONING TOOL. DUCTS LOCATED IN CRAWL SPACES DO NOT QUALIFY FOR THIS EXCEPTION. A WRITTEN REPORT OF THE RESULTS SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL. R403.3.5 BUILDING CAVITIES (MANDATORY). BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS. INSTALLATION OF DUCTS IN EXTERIOR WALLS, FLOORS OR CEILINGS SHALL NOT DISPLACE REQUIRED ENVELOPE INSULATION. EGRESS NOTES: PER IRC R310.1 BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE BASEMENTS CONTAIN ONE OR MORE SLEEPING ROOMS, EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR TO YARD OR COURT THAT OPENS TO A PUBLIC WAY. 2015 IRC R310.1.1 OPERATIONAL CONSTRAINTS AND OPENING CONTROL DEVICES EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. WINDOW OPENING CONTROLL DEVICES COMPLYING WITH ASTM F2090 SHALL BE PERMITTED FOR USE ON WINDOWS SERVING AS A REQUIRED EMERGENCY ESCAPE AND RESCUE OPENING. 2015 IRC R310.2.1 MINIMUM OPENING AREA ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF NOT LESS THAN 5.7 SQUARE FEET. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. THE NET CLEAR HEIGHT OPENING SHALL BE NOT LESS THAN 24 INCHES AND THE NET CLEAR WIDTH SHALL BE NOT LESS THAN 20 INCHES. EXCEPTION: GRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF 5 SQUARE FEET. 2015 IRC R310.2.2 WINDOW SILL HEIGHT WHERE A WINDOW IS PROVIDED AS THE EMERGENCY ESCAPE AND RESCUE OPENING, IT SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 INCHES ABOVE THE FLOOR; WHERE THE SILL HEIGHT IS BELOW GRADE, IT SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION R310.2.3. 2015 IRC R312.2.1 WINDOW SILLS IN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN OPERABLE WINDOW OPENING IS LOCATED LESS THAN 24 INCHES ABOVE THE FINISHED FLOOR AND GREATER THAN 72 INCHES ABOVE THE FINISHED GRADE OR OTHER SURFACE BELOW ON THE EXTERIOR OF THE BUILDING, THE OPERABLE WINDOW SHALL COMPLY WITH ONE OF THE FOLLOWING: 1. OPERABLE WINDOWS THAT WILL NOT ALLOW A 4-INCH-DIAMETER SPHERE TO PASS THROUGH TH OPENING WHERE THE OPENING IS IN ITS LARGEST OPENED POSITION 2. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW FALL PREVENTION DEVICES THAN COMPLY WITH ASTM F 2090 3. OPERABLE WINDOWS THAT ARE PROVIDED WITH WINDOW OPENING CONTROL DEVICES THAT COMPLY WITH SECTION 312.2.2. SECTION RODENT PROOFING: STRAINER PLATES ON DRAIN INLETS SHALL BE DESIGNED AND INSTALLED SO THAT NO OPENING IS GREATER THAN 2 INCH IN THE LEAST DIMENSION. METER BOXES SHALL BE CONSTRUCTED IN SUCH A MANNER THAT RATS CANNOT ENTER A BUILDING BY FOLLOWING THE SERVICE PIPES FROM THE BOX INTO THE BUILDING. IN OR ON BUILDINGS WHERE OPENINGS HAVE BEEN MADE IN WALLS, FLOORS, OR CEILINGS FOR THE PASSAGE OF PIPES, SUCH OPENINGS SHALL BE CLOSED AND PROTECTED BY THE INSTALLATION OF APPROVED METAL COLLARS SECURELY FASTENED TO THE ADJOINING STRUCTURE. TUB WASTE OPENINGS IN FRAMED CONSTRUCTION TO CRAWL SPACES AT OR BELOW THE FIRST FLOOR SHALL BE PROTECTED BY THE INSTALLATION OF APPROVED METAL COLLARS OR METAL SCREEN SECURELY FASTENED TO THE ADJOINING STRUCTURE WITH NO OPENING GREATER THAN i INCH IN THE LEAST DIMENSION. R302.12 DRAFTSTOPPING: IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET. DRAFTSTOPPING SHALL DIVIDE THE CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES: 1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING. 2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS -TYPE OPEN -WEB OR PERFORATED MEMBERS. R302.12.1 MATERIALS.DRAFTSTOPPING MATERIALS SHALL NOT BE LESS THAN 2"GYPSUM BOARD, $" WOOD STRUCTURAL PANELS OR OTHER APPROVED MATERIALS ADEQUATELY SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED PARALLEL TO THE FLOOR FRAMING MEMBER UNLESS OTHERWISE APPROVED BY THE BUILDING OFFICIAL. THE INTEGRITY OF THE DRAFTSTOPS SHALL BE MAINTAINED. FIRE BLOCKING SHALL BE PROVIDED IN ACCORDANCE WITH SECTION R302.11 SECTION R302.1: CONSTRUCTION, PROJECTIONS, OPENINGS AND PENETRATIONS OF EXTERIOR WALLS OF DWELLINGS AND ACCESSORY BUILDINGS SHALL COMPLY WITH TABLE 302.1 rvnroTlnnlc. 1. WALLS, PROJECTIONS, OPENINGS OR PENETRATIONS IN WALLS PERPENDICULAR TO THE LINE USED TO DETERMINE THE FIRE SEPARATION DISTANCE. 2. WALLS OF DWELLINGS AND ACCESSORY STRUCTURES LOCATED ON THE SAME LOT. 3. DETACHED TOOL SHEDS AND STORAGE SHEDS, PLAYHOUSES AND SIMILAR STRUCTURES EXEMPTED FROM PERMITS ARE NOT REQUIRED TO PROVIDE WALL PROTECTION BASED ON LOCATION ON THE LOT. PROJECTIONS BEYOND THE EXTERIOR WALL SHALL NOT EXTEND OVER THE LOT LINE. 4. DETACHED GARAGES ACCESSORY TO A DWELLING LOCATED WITHIN 2 FEET OF A LOT LINE ARE PERMITTED TO HAVE ROOF EAVE PROJECTIONS NOT EXCEEDING 4 INCHES. 5. FOUNDATION VENTS INSTALLED IN COMPLIANCE WITH THIS CODE ARE PERMITTED. CONTINUOUS WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS TABLE M1507.3.3.(1) BEDROOMS 0-1 2-3 4-5 6-7 > 7 < 1500 30 45 60 75 90 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 150 > 7500 105 120 135 150 165 404.1 LIGHTING EQUIPMENT (MANDATORY): A MINIMUM OF 75� OF LAMPS IN PERMANANTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH EFFICACY LAMPS. WAC SECTION 1507 MECHANICAL VENTILATION M1507.3.3 MECHANICAL VENTILATION RATE. THE WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM SHALL PROVIDE OUTDOOR AIR TO EACH DWELLING UNIT AT A CONTINUOUS RATE OF NOT LESS THAN THAT DETERMINED IN ACCORDANCE WITH TABLE M1507.3.3(1). EXCEPTION: THE WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM IS PERMITTED TO OPERATE INTERMITTENTLY WHERE THE SYSTEM HAS CONTROLS THAT ENABLE OPERATION FOR NOT LESS THAN 25 PERCENT OF EACH 4-HOUR SEGMENT AND THE VENTILATION RATE PRESCRIBED IN TABLE M1507.3.3(1) IS MULTIPLIED BY THE FACTOR DETERMINED IN ACCORDANCE WITH TABLE M1507.3.3(2). M1507.3.4 WHOLE -HOUSE VENTILATION USING EXHAUST FANS. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR WHOLE -HOUSE VENTILATION SYSTEMS USING EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A WHOLE -HOUSE VENTILATION SYSTEM. M1507.3.4.1 WHOLE -HOUSE VENTILATION FANS. EXHAUST FANS PROVIDING WHOLE -HOUSE VENTILATION SHALL HAVE A FLOW RATING AT 0.25 INCHES WATER GAUGE AS SPECIFIED IN TABLE M1507.3.3(1). MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED ACCORDING TO HVI 916 OR AMCA 210. M1507.3.4.2 FAN NOISE. WHOLE -HOUSE FANS LOCATED 4 FEET OR LESS FROM THE INTERIOR GRILLE SHALL HAVE A SONE RATING OF 1.0 OR LESS MEASURED AT 0.1 INCHES WATER GAUGE. MANUFACTURER'S NOISE RATINGS SHALL BE DETERMINED AS PER HVI 915 (MARCH 2O09). REMOTELY MOUNTED FANS SHALL BE ACOUSTICALLY ISOLATED FROM THE STRUCTURAL ELEMENTS OF THE BUILDING AND FROM ATTACHED DUCT WORK USING INSULATED FLEXIBLE DUCT OR OTHER APPROVED MATERIAL. M1507.3.4.3 FAN CONTROLS. THE WHOLE -HOUSE VENTILATION FAN SHALL MEET THE REQUIREMENTS OF SECTION M1507.3.2 AND M1507.3.2.1. M1507.3.4.4 VENTILATION OPENINGS. EACH HABITABLE SPACE SHALL BE PROVIDED WITH OUTDOOR AIR INLETS OR OPERABLE WINDOWS WITH AN OPENABLE AREA NOT LESS THAN 4 SQUARE INCHES OF NET FREE AREA OF OPENING FOR EACH 10 CFM OF OUTDOOR AIR REQUIRED BY TABLE M1507.3.3(1). WHERE OUTDOOR AIR SUPPLIES ARE SEPARATED FROM EXHAUST POINTS BY DOORS, PROVISIONS SHALL BE MADE TO ENSURE AIR FLOW BY INSTALLATION OF DISTRIBUTION DUCTS, UNDERCUTTING DOORS, INSTALLATION OF GRILLES, TRANSOMS, OR SIMILAR MEANS. DOORS SHALL BE UNDERCUT TO A MINIMUM OF 1/2 INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING. INDIVIDUAL ROOM OUTDOOR AIR INLETS SHALL: 1. HAVE CONTROLLABLE AND SECURE OPENINGS; 2. BE SLEEVED OR OTHERWISE DESIGNED SO AS NOT TO COMPROMISE THE THERMAL PROPERTIES OF THE WALL OR WINDOW IN WHICH THEY ARE PLACED; 3. ANY INLET OR COMBINATION OF INLETS WHICH PROVIDE 10 CFM AT 10 PASCALS ARE DEEMED EQUIVALENT TO 4 SQUARE INCHES NET FREE AREA. VENTILATION OPENING SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OPENINGS SHALL BE CONTROLLABLE, SECURABLE AND SHALL BE DESIGNED TO NOT COMPROMISE THE THERMAL PROPERTIES OF THE BUILDING ENVELOPE. VENTILATION OPENINGS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL -BURNING APPLIANCES THEREIN. 5. CLOSER THAN 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES, OR GARAGES. 7. ASPHALT ROOFS UNLESS IT IS SHOWN THAT NO OTHER LOCATION IS PERMISSIBLE. IN SUCH CASES THE INLET OPENING SHALL BE LOCATED A MINIMUM OF 2 FEET FROM THE NEAREST SURFACE OF THE ASPHALT ROOFING, MEASURED FROM THE INTAKE OPENING. R402.1.1 - PRESCRIPTIVE REQUIREMENTS CLIMATE ZONE 5 8c MARINE 4 WOOD FENESTRATION SKYLIGHT GLAZED CEILING FRAMEWALL MASS WALL FLOOR BELOW GRADE SLAB R-VALUE U-FACTOR U-FACTOR FENESTRATION R-VALUE R-VALUE R-VALUE R-VALUE WALL R-VALUE & DEPTH 0.30 0.50 NR 49 21 int. 21/21h 30g 10/15 21 10,2 ft. i nt.+TB ENERGY CREDIT (DEBIT) OPTIONS GAS - OPTION OPTION DESCRIPTION CREDITS) 5a EFFICIENT WATER HEATING Sa: 0.5 All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less.c To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the maximum flow rates for all showerheads, kitchen sink faucets, and other lavatory faucets. r ew or�� DE51GN PHONE 253.271.8501 NEW WORLDDESIGNLLC.COM U J J z c� w 0 0 J O w z 0 N 0 N >� .T Q 0 U These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TITLE MUELLER ADDITION PROJECT ADDRESS 20124 81ST AVE W EDMONDS, WA 98026 AFP OCT 27, 2020 GENERAL NOTES DRAWN J. RODRIGUEZ PROJECT # 20-111 SHEET SCALE AS NOTED SHEET NUMBER A-0.2 RESUB Feb 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FRONT ELEVATION REAR ELEVATION ELEVATION KEYNOTE; 5/4x4 TRIM TORCHDOWN ROOFING. PER OWNER EXPOSED CONCRETE STEMWALL GUTTER, PAINT TO MATCH TRIM 30 YEAR ARCHITECTURAL ASPHALT SHINGLE ROOFING HORIZONTAL SIDING TO MATCH (E), PER OWNER 1x2 O/ 2x8 BARDGE BOARD (N) WOOD FRAMED DECK 1 preservative -treated wood shall be of ■ ' hot -dipped zinc galvanized steel, I Istainless steel, silicon bronze or copper. � .In the absence of manufacturer s recommendations Ia minimum of ASTM A 653 type G185 zinc -coated I galvanized steel, or equivalent, shall be used. ■ L IRC R317.3.1 IBC 2304.10.5.1 I ARIGHT ELEVATION � LEFT ELEVATION MAX HEIGHT = +118.71' � i ew or�u DESIGN PHONE 253.271.8501 NEW WORLDDESIGNLLC.COM U J J Z U_ W 0 J >� >> W Z 0 N O N O .� 0 U These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TITLE MUELLER ADDITION PROJECT ADDRESS 20124 81ST AVE W EDMONDS, WA 98026 Rl O1/29/2021 AFP OCT 27, 2020 ELEVATIONS DRAWN J. RODRIGUEZ PROJECT # 20-111 SHEET SCALE AS NOTED SHEET NUMBER A-1.0 RESUB Feb 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT (E) MILLWORK TO BE REMOVED (E) PORTION OF DECK TO BE REMOVED :-- II II II II ---� ---�I ---�I ---�I ---�I ___JI ___ II II ---�I ---71 ---11 ---�I ---�I —__—JI AMAIN FLOOR DEMOLITION PLAN (E) WALL TO BE REMOVED u 0 u u ROOF DEMOLITION PLAN /� (E) ROOF FRAMING TO BE REMOVED e� ll�or�d i�r.Sic,N PHONE 253.271.8501 NE W W ORLDDE S IGNLLC. COM U J J Z U' W J >� >> W Z O N O N O L �L Q Q U These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TTTLE MUELLER ADDITION PROJECT ADDRESS 20124 81ST AVE W EDMONDS, WA 98026 0 AFP OCT 27, 2020 DEMOLITION PLANS DRAWN J. RODRIGUEZ PROJECT # 20-111 SHEET SCALE AS NOTED LOWER FLOOR DEMOLITION PLAN `� SHEET NUMBER A 2.0 Feb 01 2021 DEVELOPMENT SERVICES DEPARTMENT A A3.0 AREA SUMMARY (E) MAIN FLOOR LIVING (E) LOWER FLOOR LIVING (N) MAIN FLOOR LIVING (N) LOWER FLOOR LIVING TOTAL LIVING AREA (E) WOOD DECK AREA (N) WOOD DECK AREA 102 PROPOSED MAIN FLOOR PLA 102 2289 51 DRAWING LEGEND: _ _ = EXISTING WALL TO BE REMOVED A A3.0 e largest tread or riser within any flight of stairs is not to exceE s inches. Per IRC 2015 R311.7.5 refer to mybuildingpermit.com for more Intormatlon. Handrails are required on at least one side for stairways with four or more risers. Per IRC 2015 R311.7.8. Also See mybuildingpermit.com Tip Sheet 2 for additional information regarding handrails. Landings are required at the top and the bottom of stairways. A floor landing is not required at the top of an interior flight of stairs, provided a door does not swing over the stairs. Per IRC 2015 311.7.6. also refer to mybuildingpermit.com for further information. Guards shall comply with IRC 2015 R312.1. Guards shall be structurally designed to comply with 2015 IRC Table R301.5 so that the guard is designed for a 200-pound load in any direction along the top and a 50-pound point load elsewhere. Open rail guards must comply with the following a 6" sphere cannot pass through the space created by the bottom rail and the stair. A 4" sphere cannot pass through a bottom rail and decking. A 43/8 sphere cannot pass through a descending or ascending set of intermediate pickets. See mybuildingpermit.com Tip Sheet 3 for more information. OUTLINE OF FLOOR ABOVE If either water heater or furnace are are gas fired appliances, this location is not allowed nPr IRC: 7fl1.ri (��4flFi � unlP�� nnP of the r'� d � � � r � f �! PHONE 253.271.8501 NEW WORLDDESIGNLLC.COM U J J Z C� W 0 J >0 >> W Z 0 N O N L �L Q 0 U These plans are copyrighted in TO VERIFY accordance with federal s, IF NOT statutes. Re roduction b an EPLACE p y y (N) SAFETY method of all, part or variations 'W thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TITLE MUELLER A ADDITION A3.0 PROJECT ADDRESS 20124 81 ST AVE W EDMONDS, WA 98026 Rl O1/29/2021 AFP OCT 27, 2020 PROPOSED FLOOR PLANS DRAWN J. RODRIGUEZ PROJECT # 20-111 SHEET SCALE AS NOTED NEW WALL EXISTING WALL TO REMAIN SHEET NUMBER � A-//�/ 1 Feb 01 2021 ` ■ ■ DEVELOPMENT SERVICES DEPARTMENT z 0 (E) FRAMING TO REMAIN (E) SLAB TO REMAIN TORCHDOWN ROOFING, INSTALL PER MFG wz (E) STRUCTURE BEYOND /� MAT i � (E) Q 3 2x6 RAFTERS @24" O.C., OR PER STRUCT. CLOSED CELL SPRAY FOAM AT RAFTER CAVITIES MIN R-38, TYP UNO I � � 7 ���i/ A5.0 3/4" T&G PLYWD SUB-FLR (GLUED &NAILED) 0/ (E) JOISTS TYPICAL ROOF ASSEMBLY: • 30 YR. ARCH. LAM. COMP. SHINGLE • (CLASS B - MIN) • 15# ROOFING FELT • 7/16" OSB SHT'G • RAFTERS PER STRUCT. 1 � — � � A5.0 TYPICAL EXTERIOR WALL ASSEMBLY: \ • 2-2X6 TOP PLATES i � 2X6 STUDS 16" O.C. � / 2X6 BOTTOM PLATE (TRT'D ON � / ,� CONC.) i > WEATHER BARRIER _ � � 7/16" OSB � LAP SIDING OR STONE VENEER 00 PER ELEVATION v R-21 BATT INSUL. W/ VAPOR = BARRIER AT WARM SIDE Q • 1 /2" G.W.B. � `\ � —�--- 1 / �, -i 3 A5.0 A PARTIAL BUILDING SECTION i� rJ a � FOUNDATION PLAN TYPICAL ROOF ASSEMBLY: • 30 YR. ARCH. LAM. COMP SHINGLE • (CLASS B - MIN) • 15# ROOFING FELT • 7/16" OSB SHT'G • RAFTERS PER STRUCT. • CLOSED -CELL SPRAY FOAI AT RAFTER CAVITIES MIN R-38 TYP UNO TYPICAL EXTERIOR WALL ASSEM • 2-2X6 TOP PLATES • 2X6 STUDS 16" O.C. • 2X6 BOTTOM PLATE (TRT'C CONC.) • WEATHER BARRIER • 7/16" OSB • LAP SIDING OR STONE VEf PER ELEVATION • R-21 BATT INSUL. W/ VAI BARRIER AT WARM SIDE • 1/2" G.W.B. I\- I V I\IVIV IIVJVL /'11 PERIMETER OF (E) SLAB P1V z1PARTIAL BUILDING SECTION r ew or �D�51�N PHONE 253.271.8501 NEW WORLDDESIGNLLC.COM U J J z w 0 0 J O w z 0 N 0 N �L Q 0 U These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TITLE MUELLER ADDITION PROJECT ADDRESS 20124 81 ST AVE W EDMONDS, WA 98026 Rl O1/29/2021 AFP OCT 27, 2020 FOUNDATION PLAN AND PARTIAL BUILDING SECTIONS DRAWN J. RODRIGUEZ PROJECT # 20-ll1 SHEET SCALE AS NOTED SHEET NUMBER � ^/ Feb 01 2021 A2 . ` DEVELOPMENT SERVICES DEPARTMENT LL �l SEE STRUCTURAL ENGINEERING FOR REQUIREMENTS (E) RIDGE r w J ROOF PLAN 1/� 4:12 V.I.F. I 3•.12► w c9 0 �9< (N) UNVENTED ROOF AREA AT HATCHED AREA �w > �- � U 1'-6" VIF .I Q MATCH (E) ^ � PHONE 253.271.8501 NEW WORLDDESIGNLLC.COM U J J Z C� W J >� >> W Z 0 N O N J L Q Q U These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TITLE MUELLER ADDITION PROJECT ADDRESS 20124 81 ST AVE W EDMONDS, WA 98026 AFP OCT 27, 2020 UNVENTED ROOF PLAN DRAWN PROJECT # SHEET SCALE J. RODRIGUEZ 20-111 AS NOTED SHEET NUMBER Feb 01 2021 A 4.0 DEVELOPMENT SERVICES DEPARTMENT ��ITYPICAL WINDOW FLASHING ���TYPICAL DOOR FLASHING (N; R-21 BATT CONT. VAP( 1" RIGID 2x4 FURRIN R-15 BATT Y" GWB @ (E) RETAIL (E) CONCF �nIINSUL WALL E) FLOOR FRAMING (E) BLOCKING (E) SILL PLATE RETAINING WALL COMP. SHINGLE ROOFING " � " ROOFING FELT ' CDX OR 7/16" OSB SHT'G �E CCX AT EXPOSED EAVES) . TRUSSES OR RAFTERS PER �11NG PLANS 3LOCKING SIMPSON HURRICANE TIE SEE ENGINEER DETAIL F( TYPE AND NUMBER. 2" RIGID INSULATION oT ax uFgDERS SEE PLAN 5 EAVE W/ INSUL. HDR COMP. SHINGLE ROOFING " � " ROOFING FELT " CDX OR 7/16" OSB SHT'G �E CCX AT EXPOSED EAVES) . TRUSSES OR RAFTERS PER �11NG PLANS 3LOCKING CLOSED CELL SP FOAM AT RAFTER MIN R-38, UNO TYPICAL EXTERIOf SEE SECTIONS & SEE PLAN � EAVE CONNECTION CLOSED CELL SPRA" �^"�� AT RAFTER BAYS MIN f COMP. SHINGLE ROi METAL RAKE EDGE P.T. LEDGER PER STRUCT FLASHING (MIN. 2"x DECKING 1x2 ON 2x8 BARGE TREATED JOISTS PER PLAN 2x4 OUTRIGGERS. - JOIST HANGER PER STRUCT SIDING PER ELEVATI' 6 DECK FRAMING EXISTING CONC SLAT 7 SLAB �� (E) SLAB 8 NOT USED GABLE END RAFTER 2 TYPICAL RAKE TYPICAL EXTERIOR WALL ASSEMBLY ANCHOR BOLTS PER ENG. SHE:ARWALL SCHED. P.T. 2X6 SILL PLATE 6" MIN. CLEAR. EARTH '� TO WOOD. GRADE TO SLOPE AWAY � a"� FROM BLDG. REINFORCEMENT PER a ENG. DETAILS ' c.� w as �, � � a �, a a I R-21 BATT INSULATION W/ CONT VAPOR BARRIER AT WARM SIDE. SEE ENG. � � SLAB ON GRADE 4 NOT USED EXISTING CONCRETE SLAB TO REMAIN R-10 x 24" RIGID SLAB INSUL. AT PERIMETER OF SLAB, SAWCUT (E) SLAB AS REQ'D r ew or�� °'' �I�:�I�i PHONE 253.271.8501 NEW WORLDDESIGNLLC.COM U J J z C� w J w z 0 CV 0 CV �L n 0 U These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TITLE MUELLER ADDITION PROJECT ADDRESS 20124 81 ST AVE W EDMONDS, WA 98026 0 AFP OCT 27, 2020 DETAILS DRAWN J. RODRIGUEZ PROJECT # 20-111 SHEET SCALE AS NOTF� � L+ SHEET NUMBER FReb 01 021 CITY OF ED ONDS A 5 � O DEVELOPMEN SERVICES DEPART ENT CONTRACTOR SHALL CONSULT BOTH THE WINDOW MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO FRAMING AND INSTALLATION OF WINDOWS. AND THE AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION STANDARD AAMA 2400-02 FOR INSTALLATION AND WEATHERPROOFING DETAILS. 1. ROUGH -IN WINDOW OPENING. 4. APPLY CONT. SEAL TO THE BACKSIDE OF THE MOUNTING FLANGE NEAR THE OUTER EDGE AND INLINE WITH ANY PRE -PUNCHED HOLES OR SLOTS ON THE MOUNTING FLANGE. SHIM &ADJUST WINDOW TO PLUM & LEVEL. USE CORROSION RESISTANT FASTENERS. 2. APPLY SILL FLASHING HORIZONTALLY BELOW SILL. FASTEN TOP EDGE ONLY. EXTEND SILL FLASHING HORIZONTALLY 9" BEYOND VERTCAL JAMB. 5. APPLY CONT. SEAL ALONG TOP (HEAD) MOUNTING FLANGE. EMBED BOTTOM OF HEAD FLASHING AGAINST SEALANT (FLASHING GOES OVER SEALANT) EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. 3. APPLY JAMB FLASHING VERTICALLY EXTEND BEYOND SILL FLASHING AND ABOVE WHERE HEAD FLASHING WILL INTERSECT. LEAVE BOTTOM EDGE UNATTACHED. 6. INSTALL BUILDING PAPER IN A WEATHERBOARD FASHION. SLIP BOTTOM OF JAMB FLASHING & SILL FLASHING OVER BUILDING PAPER AT BOTTOM OF WINDOW SILL 8 TYPICAL WINDOW FLASHING NTS ��WINDOW HEAD KING STUD & TRIMty 6 WINDOW JAM B 7 WINDOW SILL LAP SIDING MTL. HEAD FLASHING (MIN. 3" UPTURN)W/DRIP EDGE CASING OR TRIM PER ELEVATION, RABBET TO FIT WINDOW FLANGE MFG. WINDOW FRAME. INSTALL PER MFG. SPEC'S LAP SIDING CAULK SPACE PROVIDE FLASHING TAPE (NOT SHOWN) CASING OR TRIM PER ELEVATION, RABBET TO FIT WINDOW FLANGE CAULK SPACE MFG. WINDOW FRAME. INSTALL PER MFG. SPEC'S MFG. WINDOW FRAME. INSTALL PER MFG. SPEC'S PROVIDE SILL FLASHING PER MFG. SPEC. (NOT SHOWN) CASING OR TRIM PER ELEVATION, RABBET TO FIT WINDOW FLANGE LAP SIDING SHIM SPACE � � DOOR HEAD iunnn rncinic Y" G.W.B. 2x6 STUD 2x6 KING 2x6 TRIMM��� STU D � � DOOR JAMB LAP SIDING MTL. HEAD FLASHING (MIN. 3" UPTURN)W/DRIP EDGE DOOR CASING DOOR JAMB OR JAMB IM SPACE �� ���1-id DE51GN PHONE 253.271.8501 NEW WORLDDESIGNLLC.COM U J J Z U_ W J O w Z 0 N O N �L Q O U These plans are copyrighted in accordance with federal statutes. Reproduction by any method of all, part or variations thereof without written permission from New World Design, LLC is expressly prohibited. These drawings and all prints therefrom remain the property of New World Design, LLC PROJECT TITLE MUELLER ADDITION PROJECT ADDRESS 20124 81ST AVE W EDMONDS, WA 98026 L� AFP OCT 27, 2020 DETAILS DRAWN J. RODRIGUEZ PROJECT # 20-111 SHEET SCALE AS NOTED R E S U B Feb 01 2021 SHEET NUMBER CITY OF EDMONDS A5 � DEVE DEPARTMENRVICES . ��RI�C�I�RAL_ NO���: CODE: CODE: INTERNATIONAL BUILDING CODE 2015 a ASCE 1-10 LOADS: ROOF SNOW= 25 F'SF, FLOOR 4 STAIR LIVE= 40 F'SF, DECK LIVE= 60 F'SF ROOF DEAD= 14 F'SF, FLOOR DEAD= 12 F'SF, DECK DEAD= 10 PSF SEIS: GROUP I, CATEGORY 'D', R= 65 Ss = 1219 g, S , = 0b01 g, S� = 0.853 g, Sp,= 0.501 g WIND: 85 IASD) MPH ,EXPOSURE 'B', Kn= 1.00 FOUNDATIONS: EXTEND FOOTINGS TO FIRM UNDISTURBED SOIL, ASSUMED BEARING CAPACITY OF 2000 F'SF. ALL EXTERIOR FOOTINGS SHALL EXTEND A MINIMUM OF I'-6' BELOW ADJACENT EXTERIOR CAST- IN -PLACE CONCRETE: F'c=2,500 PSI � 28 DAYS. MINIMUM 5-I/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5' OR LESS. MAXIMUM SIZED AGGREGATE IS I-I/2 INCHES. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED ANp PLACED IN ACCORDANCE WITH IBC SECTION 1905,1906 ANDACI 301, INCULING TESTING PROCEDURES. ALL PHASES OF WORK PERTAINING TO THE CONCRETE CONSTRUCTION SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE. ALL REINFORCING STEEL DOWELS, ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN POSITION PRIOR TO POURING CONC. REINFORCINC-c STEEL: ALL �INFORCING STEEL SHALL BE PLACED IN CONFORMANCE WITH THE BUILDING CODE REQUIREh1ENTS FOR REINFORCED CONCRETE AND THE MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION BY CRSI. DEFORMED REINFORCING STEEL BARS SHALL CONFOR'1 TO ASTM GRADE 60. ALL �INFORCING BAR BENDS SHALL BE MADE COLD, WITH A MINIMUM RADIUS OF 6 BAR DIAMETERS (1'-l' MINIMUM). CORNER BARS (2'-0' BEND) SHALL BE PROVIDED FOR ALL HORIZONTAL REINFORCEMENT. LAP ALL BARS A MINIMUM OF 48 BAR DIAMETERS UNLESS NOTED OTHERWISE. UNLESS OTHERWISE NOTED ON THE DRAWINGS REINFORCING STEEL SHALL NAVE THE FOLLOWING MINIMUM COVER: CONCRETE CAST AGAINST EARTH 3' CONCRETE EXPOSED TO EARTH OR WEATHER: I��z' CONCRETE NOT EXPOSE TO EARTH OR WEATHER: MI BAR AND SMALLER 3ia' SLAB -ON -GRADE (FROM TOP SURFACE) Il�z' STRUCTURAL TIMBER: ALL GRADES SHALL CONFORM TO WWPA GRADING RULES FOR WESTERN LUMBER, LATEST EDITION. PROVIDE CUT WASHERS UNDER ALL NUTS AND BOLTS BEARING AGAINSt WOOD. ALL WOODS IN CONTACT WITH CONCRETE OR EXPOSE TO WEATHER SHALL BE PRESSURE TREATED. ALL STRUCTURAL LUMBER SHALL BE NOTED BELOW: 2x4 +E 2x6 SILL tE, 3x6, 4x4 POST, 4x BEAM DOUGLAS-FIR /LARCH *2 LUMBER NOT NOTED HEM -FIR "2 MISCELLANEOUS HANGERS TO BE SIMF'SON OR APPROVED EQUAL. ALL HANGERS SHALL BE FASTENED TO WOOD WITH MAXIMUM NAILS -ALL HOLES SHALL BE NAILED. ALL NAILS SHALL BE COMMON WIRE NAILS. PROVIDE NAILING SHALL BE IN ACCORDANCE WITH 'I.B.C. 2015' TABLE 2304.10.1 FASTENING SCHEDULE. ROOF � FLOOR SNEATNINCa: ROOF SHEATHING SHALL BE I/2' A.P.A. RATED SHEATHING. 5-PLY, SPAN RATING 32/16, INSTALLED LONG DIMENSION ACROSS SUPPORTS. PANEL END JOINTS SHALL OCCUR AT SUPPORTS. NAIL AT PANEL EDGES WITH 10d COMMON 1=0.148'mx21�z') a 6' O.C. AND 12' O.C. AT INTERMEDIATE SUPPORTS. FLOOR SHEATHING SHALL BE 3/4' TdG SPAN RATING 40/20 WITH 10d COMMON a 6' O.C. (EDGE) AND 10' O.C. IINTER'1). USE *10 SCREWS 12��z' LONG) IN LIEU OF 10d COMMON NAILS AT FLOOR CONTRACTOR'S OPTION. INSTALL PLYWOOD CLIP AT 48 INCHES ON CENTER BLOCKING IS REQ'D ALL PANEL EDGES. ANCHOR BOLTS: ANCHOR BOLTS TO BE A-301 OR BETTER ANCHOR BOLTS INTO CONCRETE SHALL BE s%'mxl0' WITH l INCHES OF EMBEDMENT � SPACED NOT MORE THAN 4' APART. THERE SHALL BE A MINIMUM OF TWO BOLTS PER PIER WITH BOLT LOCATED NOT MOB THAN 12 INCHES OR NOT LESS THAN 4 INCHES FROM EACH END OF EACH PIER A PROPERLY SIZED NUT WITH 3'x3'xl/4' B WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT TO THE P.T. SILL PLATE. GLUED -LAMINATED TIMBER: LAMINATED TIMBER SHALL BE DF/DF AND Exx = 1,800 ksi Eyy = Ib00 ksi ST�SS GRADE COMBINATION 24F-Y4 (Fb=2,400 PSI, Fv=165 PSI) FOR SIMPLE SPANS. A.I.T.C. CERTIFICATE OF CONFORMANCE REQUIRED. GLU-LAMS SHALL CONFORM TO A.I.T.C. STANDARD Ill. FABRICATOR SHALL SUBMIT THE DETAILS AND SPECIFICATIONS TO THE ENGINEER OR ARCHITECT FOR APPROVAL PRIOR TO FABRICATION. TIM�ERSTRAND LSL: LSL SHOWN ON PLAN TO BE 13E TIMBERSTRAND LSL OR APPROVED EQUAL. OTHER THAN 13E TIMBERSTRAND LSL SHALL NAVE ICBO APPROVALS SUBMITTED TO 7NE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW. Fb=I,100 psi., Fv = 400 psi, Fc= 680 psi, E= 1,300,000 psi. SPECIAL INSPECTIONS: PROVIDE SPECIAL INSPECTIONS IN ACCORDANCE WITH 'IBC 2015' FOR FOLLOWING: REINFORCING PLACEMENT PERIODIC a PRIOR TO ALL CONCRETE POURS ANCHOR BOLT PLACEMENT PERIODIC d PRIOR TO ALL CONC�TE POURS EPDXY GROUTED ROD OR REBAR PERIODIC INCLUDING INSPECTION OF EMBEDMENT DEPTH 4 HOLE CLEANLINESS PRIOR TO ALL INSTALLATION SPECIAL CONDITIONS: THE CONTRACTOR SHALL V1=RIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ALL DISCREPANCIES SHALL BE SPORTED TO THE ARCHITECT OR ENGINEER THE CONTRACTOR SHALL PROVIDED ADEQUATE SNORING AS REQUIRED UNTIL PERMANENT CONNECTIONS AND STIFFENING NAVE BEEN INSTALLED. THE CONTRACTOR SHALL VERIFY SIZE AND ALL LOCATIONS OF ALL OPENINGS IN THE FLOOR, ROOF, AND WALLS WITH ALL THE APPROPRIATE DRAWINGS. THE CONTRACTOR SHALL COORDINATE WITH THE E�IILDING DEPARTMENt FOR ALL E�IILDING DEPARTMENt REQUIRED INSPECTIONS. DO NOT SCALE THE DRAWINGS. THE DETAILS SHOWN ARE TYPICAL AND SHALL BE USED FOR LIKE OR SIMILAR CONDITIONS NOT SHOWN. TYPICAL EXTERIOR UJALL CONSTRUCTION: I. SHEATHING: ��z' APA RATED SHEATHING, EXTERIOR GLUE, EXTERIOR SIDE OF WALL, PANELS ARE APPLIED WITH LONG DIMENSION ACROSS STUDS, ALL PANEL EDGES BLOCKED, NAILING: 0.131m'x2�iz' NAIL a 6' O.C.: EDGES AND BOUNDARIES 0.131'mx2�iz' NAIL ®12' O.C.: FIELD. 2. BOLTS AT P.T. 2x6 SILL PLATE TO CONCRETE WITH sis'm A. BOLTS o 48' O.C. ll' EMBED) A. BOLTS TO BE PLACED 4' TO 12' FROM END OF EACH PLATE. ALL A. BOLTS SHALL BE SECURED WITH 3'x3'x�ia' PLATE WASHER 3. EXTERIOR STUD SHALL BE 2x6 DF *2 � 24' O.G. 4. FASTEN DOUBLE PLATE TO JOIST OR BLOCKING ABOVE WITH 0.148'mx3' TOE NAIL � 6' O.C. 5. Sd COMMON: 0.131m'x2'iz' , 10d COMMON: 0.148'mx3',16d COMMON: 0.161'mx3'iz' ��z' PLYWOOD W/ TYP. EXTERIOR WALL NAILINCs VERIFY ALL 3'-10' 5'-0" DIMENSION IN FIELD 08 ROOF , l2)-2x6 HDR _� WINDOW � m 0 c!J 0 DTT2Z 'MST3l' �� (SEE '03') (t) I'-3' "' FLOOR (SEE '05') , 61 2)-2x6 HD 'MSTA49' W/ WINDOW EXIST 0 3x6 BLK'G WINDOW m � � 4 COMER r 0 ._. 1�1 ' m TOP OF 'NDU2' (SEE '05') CONC. 2'-3" 5'-0' 2'-10" ��z' PLYWOOD W/ TYP. EXTERIOR WALL NAILING SOUt� UJALr� SCALE: pia' = I'-0' ELBOW BAR: SAME SIZE t SPACING AS NORIZ. BAR LAP *4 BAR: 30' MIN '� WALL REINF. PER OTHER SECTION DOWELS: DRILL s�s'mx4�iz' HOLE INTO lE) CONC. WALL 4 SET *4 REBAR W/ SIMF'SON 'SET' EPDXY. n CORN�i� i�� INF. w� SCALE: I' = I'-0' 1'-0" IMIN) a • II-III=III ' ' i I —I I I- 4' SLAB ON CaRADE 11" (SEE ARCH • ° ° *4 NOSING r � Q • • 4' *4 � 16' O.G. *4 � EA. RISER (U-*4 CO1�lC. S�AfR �� SCALE: 1" = 1'-�" l2)-16d TOE NAIL g EA. END ITYP) l4)-16d T N A HEADER � (O PE DER (SEE PLAN) USE (I) -JACK ll) KING 16d � 16' O.G. STUD BETWEEN STUD (TYP) BEAM PERP. TO WALL: 3�izx CaLB : (2) JACKS MIN. UNDER BEAM ��AD�R �2 SCALE: 1" = 1'-f�" (2)-2x6 � STRAP W/ EDGE NAIL 3�a' PLYWD. SHT'Ca � RIM (2)-2x6 � STRAP W/ EDGE NAIL 4 C� w 'MST3l' STRAP (SEE PLAN) BENT � HEADER Q C� w PLl'WD. Sl-IT'Cs '1`�I'��3�' ��fi�,�P 'NDU2' W/ (2)-2x STUDS W/ EDGE NAIL 'DTT2Z' W/ l6) ��a-2��z SDS x x (8)-��ax1��zSDS TO TO (2)-2x STUDS x x STUDS d ��y'm LAG x x SCREW TO 4x10 P.T. 2x SILL fE DRILL 3�4'mx10' HOLE �iz'mxl2' LAG SCREW ° INTO lE) 6' GONG. WALL °a d SET 5i8'm (A30�) ROD � ° W/ SIMPSON 'SET' EPDXY. \ / (E) 2x8 � 16' O.C. ° OR 'SSTBI6' 1125�8' EMBED) I X I 4x8 ll'-0' MIN.) BLK'G ° � NEW CONC. WALL / \ � �iz'm LAG SCREW '� d d ° � 6' CONC. WALL ISEE PLAN) (E) 4x10 BEAM m� �-IOLD DOUJN SCALE: I' I'-0' 4x4 POST W/ 8'x8' PLINTH (3)-l�ia'xl4' TIMBERSTRAND LSL OR 16'xl6' PB44 OR CB44 FOOTING W/ 'A35' � P.T. 2x6 fE < 'LSC' � 4x DECK BEAM PLl'WD. - 2x6 � 24' O.C. I ( ) STU WA '—' ' '— a° ' I E D LL III�III III�III SHT G P.T. 2x6 SILL IE W/ 5ia'm A. BOLT � I (l' EMBED) � fE��ax3x3 g 48' O.C. z d a � d EDGE NAIL (E) 4' CONC. SLAB ON GRADE � (E) 4' CONC. � (SAW GUT FOR NEW INSULATION) SLAB ON GRADE _`� d 4 d-° ° � ai d d III —III —III —I I ° � ° ° � d 11-III=III_111= VERT: �� o� wa��� °I a a z d ° HORIZ: *4 * 16' O.C. d �� (E) CONC WALL , ll)-*4 I -4 � SEE ARCH FOR INSULATION —° L � � FOOTING 16'xl6'x8' FOOTING � ° ° ° ° REBAR NOT REG2'D _� ° ° ° _ d d ° d° d ° �' � °° � la ° � °I L-�--J D��Af � � u Q 6° Q (2)-*4 I'-0" (SEE PLAN) s� c� � o� ��� SCALE: 1" = 1'-f�" 2x6 � 24' O.G. 10d � 6' O.C. EDGE NAIL (2)-10d PER BLK'G (ONE g EA. SIDE) 10d � 8' O.C. (2)-10d (3' O.C.) 2x8 BLK'G � EDGE NAIL 4'-0' O.G. W/ 10d � 6' O.G. PLYWD. � 2x6 � 24' O.G. SNT'G S� C� � Ol�l � �� SCALE: 1" = 1'-f�" s� c� � o� ��2 SCALE: 1" = 1'-�" REPLACE (E) Ix4 DECKING W/ NEW 3ia' TEG PLYWOOD SNT'G 10d � 10d � 6' O.C. 8' O.C. lE) FLOOR SNT'G �� n �� 5ia'm TNRU BOLT g 16' O.C. (VERIFI' IN FIELD) EDGE - NAIL lE) 2x8 PLYWD. — JOIST (E) 2x8 SHT'G LEDGER �� lE) STUD WALL s� c� � o� � � SCALE: 1" = 1'-�" ,�3 SCALE: 1" = 1'-�° 'LUS26' OR 'U26' HANGER Sd � 6' O.G. L 2x6 RAFTER (SEE PLAN) 'H3' PER RAFTER (NOT SHOWN) 2x6 � 24' O.G. P.T. 2x6 iE W/ v�, l2)-5ia'mx10' A. BOLTS (32' O.C.) d I I II °° III —III z � e � °d l2)-*4 61 d 10' �� C� I Ol�l Sd � 6' O.G. l2)-10d PER RAFTER LONE � EA. SIDE) � Sd � �� % I 6' O.G. 3��z' GLB W/ 2x6 SHIM � TOP RAFTER (SEE PLAN) (SEE PLAN) I 1�8 S� C� I Ol�l SCALE: 1" = 1'-�" 2x8 W/ (2)-Sd (3' O.C.) TO 2x8 BLK'G (2) ROWS OF 16d � 3' OC (TOTAL 12 EA. SIDE) i-inv a �cc v rv� rv�� i TOP OR BOTTOM iE SPLICE �P� �C� 4x4 GUARD RAIL g 48' O.G. (MAX) W/ l2)-5ie'm TNRU BOLTS (4' O.G.) Ix4 DECKING W/ (2)-Sd TO EA. 2x8 JOIST (NOT SHOWN) \ � � (2)-Sd \V V (3' O.C.) 2x8 BLK'G � 32' O.C. W/ (3)-Sd � DECKING 4x4 GUARD RAIL � 48' O.G. (MAX) 2x6 �+ 24' O.C. W/ l2)-5/8'm THRU BOLTS (4' O.G.) EDCzE NAIL 10d � 6' O.C. Ix4 DECKING W/ (2)-Sd TO � *, Sd � 6' O.G. EACH JOIST (NOT SHOWN) 2x8 RIM 6' O.G. 2x8 W/ A35 � 16' O.C. (2)-Sd (3' O.C.) EDGE v TO EA. JOIST NAIL /� (2)-10d PER JOIST 2x8 W/ 'LUS26' � lE) 2x8 JOIST LONE � EA. SIDE) EDGE X (SEE PLAN) ISEE PLAN) NAIL (E) 4x10 4x BEAM 'DTTIZ' m FIRST 2x8 LEDGER (SEE PLAN) (SEE PLAN) l2) JOIST FROM W/ (2)-16d (3' O.C.) EACH END OF � 8' O.C. 2x6 � DECK. 24' O.C. 'DTT1Z' W/ 3�8' HDG LAG SCREW W/ HDG WASHER OR SDWH TIMBER -HEX HDG SCREW INTO TOP fE, STUD, OR JOIST (3' MIN. THREAD PENETiv4TION) � �� C� � O� � (2)-Sd (2��z' o.c.) �� SCALE: 1" = 1'-f�° TO EA. BLK'G Sd � 6' O.G. 10d � l2)-10d PER BLK'G 8' O.C. � (ONE � EA. SIDE) , _ I lE) STUD WALL 2x6 BLK'G � EDCxE NAIL 4'-0' O.G. W/ Sd � 6' O.C. _ 'H3' PER BLK'C� PLYWD. (NOT SHOWN) SHT'G 2x6 � 24' o.c. 1� �� C� � Ol�l ADDITION EXIST Sd � 6' O.G. == 2x6 RAFTER ISEE PLAN) (E) RAFTER 'HU412' HANGER � 3�iz'xl2' GLB 4x12 (SEE PLAN) (NOT SHOWN) 11� S� C� � O� SCALE: 1" = 1'-�" REVISIONS: NO. PATE DESCRIPTIONS 0 0 0 0 D. S. Engineering Consulting Structural Engineers 3121 147th Place SE Mill Creek, WA 98012 T: 425-338-4776 II/05/2020 IL S ���G OF WAS��O,� � � I F,� T � I � � �.�i �+PG 28398 �yw�'�CV ��' c�RAL E��l �SSIDNAL ���ti� C�II �y \>C II I�I II U DATE: November 5, 2®2® SCALE: SEE PLAN JOB NO.: 2®-84� DRAUJN: �. s. CHECK: �. s. SHEET TITLE C��N�R,4L NO��S t�l'PICA� D�tAILS AND S� CT I ONS S���T RESUB F 01 20 CIT F EDMON DEVEL MENT SER CES D ARTMENT ■ 1 FOUNDATION PLAN ALT: 1 PC4Z: � � U P P E R FLOOR FRAMING PLAN CCQ 44SDS2.5 OR CC44 2 EPC4Z ECCQ 44SDS2.5 OR ECC44 REVISIONS: NO. DATE DESCRIPTIONS 0 1/29/21 PLAN REVISIONS 0 0 D. S. Er��,iir�PPr-ir��,i Consulting Structural Engineers 3121 147th Place SE Mill Creek, WA 98012 T: 425-338-4776 1/29/2021 �p�� S�1 � RA �Y��°� 5`S@�� `"�,` � �� � �� �'�'p 28398 c�RAL �+�' E� ��`_ ��' �S'sI�NAL ���ti� O � � 0 � o 0 a� � Q � Q Q � � � c� � � � � � � � � � � N o � � � O � C\1 W H U w O DATE: November 05, 2020 SCALE: SEE PLAN JOB NO.: 20-870 DRAWN: �. s. CHECK: �. s. SHEET TITHE FOUNDATION AND UPPER FEOOR FRAMING PLANS SHEET RESUB Feb 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT c��N (E) RIDGE �P��� �``� �FJ �'�l <� 1� V. I . F. T� w c� w 0 � J Q W w (E) FRAMING TO REMAIN 110 S1.0 4x12 RAFTER > w c� I m \1 w m 108 N X S1.0 o 3:1 2 V. I . F. � 3:1 2 V. I . F. I N N I 2 6 RAFTERS (�24" O.C. �q F� 6x10 HDR 109 S1.0 � ROOF FRAMING PLAN 1 /4 - 1 -0 108 S1.0 REvisioNs: NO. DATE DESCRIPTIONS D. S. Engineering Consulting Structural Engineers 3121 147th Place SE Mill Creek, WA 98012 T: 425-338-4776 11/05/2020 O�G IL Sk �A���WA���� '"�,- � � � "drp ad'p 28398 c�RAL ��, �+� E� '� �S'��NAL E��1 O � �0 0 Q� w �� `� Q +� ICJ � U� � � � N O O�� U W O DATE: November 05, 2020 SCALE: SEE PLAN JOB NO.: 20-870 DRAWN: D. S. CHECK: D. S. SHEET TI TEE ROOF FRAMING PLAN SHEET ■ RESUB Feb 01 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT