BLD2020-1292+Energy_Calculations+11.24.2020_2.01.41_PMBLD2020-1292 RECEIVED Simple Heating System Size: vraa hillrytv1r State Dec 04 2020 This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and AGtAc OF EDMo IDS Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determifi@Y 61f NT s VICES loads. THE IN T Please fill out all of the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Project Information Contact Information Mueller Addition Mueller, Jake 20124 81st Ave W 20124 81st Ave W Edmonds, WA 98026 Edmonds, WA 98026 Heating System Type: ® All other systems o Heat Pump To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature Instructions — Design Temperature Difference (AT) Edmonds A = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 204 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.0 1,632 Glazing and Doors U-Factor X Area - UA Instructions u-0.30 � � 0.300 74 22.20 SkVlights U-Factor X Area - UA Instructions 0.50 0 --- Insulation Attic U-Factor X Area = UA ,structions R-38 Advanced 0.026 194 5.04 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project. Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21 Intermediate I � 0.056 246 13.78 Floors U-Factor X Area UA Instructions No Floors above unconditioned spaces. � Below Grade Walls (see Figure 1) U-Factor X Area UA Instructions No Below Grade Walls in � 0.028 0� this project. Slab Below Grade isee moure ti F-Factor X Length UA Instructions � 0.303 0� No Slab Below Grade in this project. Slab on Grade (see Figure n F-Factor X Length UA Instructions 0.540 41 22.14 R-10 Perimeter Location of Ducts Instructions Duct Leakage Coefficient Unconditioned Space 1.10 Sum of UA 63.16 Figure 1. Above Grade 46 Envelope Heat Load 2,905 Btu/Hour Sum of L A X AT Air Leakage Heat Load 811 Btu / Hour VolumeX 0.6XATX.018 Building Design Heat Load 3,716 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 4,088 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 5,723 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07101113) -E -E Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. f Reserved. g Reserved. b Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. Reserved. k For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38. Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3.