Loading...
REVIEWED BLD2022-0061+Structural_Analysis_or_Calculations+1.18.2022_10.16.35_AM+2625951REVBY I EWE D BLD2022-0061 CITY r Charging Station Edmonds, WA STRUCTURAL ANALYSIS For Electrical Equipment Anchorage and Pad Prepared for EVgo Services 11390 W. Olympic Blvd Suite 250 Los Angeles, CA 90064 Y Blymyer Engineers, Inc. 1101 Marina Village Parkway, Suite 100 Alameda, CA 94501 510.521.3773 Project No. 221193 October 8, 2021 RECEIVED Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCE AMERICAN SOCIUY OF CIVIL ENGINEERS Address: 21900 Highway 99 Edmonds, Washington 98026 RECEIVED ASCE 7 Hazards Report Jan 18 20 22 CITY OF EDMONDSDS DEVELOPMENT SERVICES Standard: ASCE/SEI 7-16 Elevation: 358.91 ft (NAVD 88) DEPARTMENT Risk Category: II Latitude: 47.800751 Soil Class: D - Default (see Longitude:-122.333394 Section 11.4.3) t i Edmcn� Alo iiixln,c � err. L;ncr., rc; r- r�r„� . .I�•�� Bmn II nwc - Knnmrm .;�� Shpre line � _ ��no0lnrnb Ralk I KUIJl nn__ It eomo Uc Lr J ' mar: � rail Wind Results: Wind Speed: 98 Vmph 10-year MRI 67 Vmph 25-year MRI 74 Vmph 50-year MRI 78 Vmph 100-year MRI 83 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1 B and Figs. CC.2-1—CC.2-4, and Section 26.5.2 Date Accessed: Fri Oct 08 2021 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane -prone region as defined in ASCE/SEI 7-16 Section 26.2. https://asce7hazardtool.online/ Page 1 of 3 Fri Oct 08 2021 -ASCE® AMERICAN SOCIUY OF CIVIL ENGINEERS Seismic Site Soil Class: D - Default (see Section 11.4.3) Results: Ss : 1.281 Sol : N/A S, 0.45 TL 6 Fa 1.2 PGA: 0.545 FV N/A PGA M : 0.654 SMS : 1.537 FPGA 1.2 SM, N/A le 1 SIDS : 1.024 CV 1.356 Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Data Accessed: Fri Oct 08 2021 Date Source: USGS Seismic Design Maps RECEIVED Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT https://asce7hazardtool.onIine/ Page 2 of 3 Fri Oct 08 2021 RECEIVED ASCE Jan 18 2022 CITY OFFEDMONDSDS AMERICAN SOCIETY OF CIVIL ENGINEERS DEVELOPMENT SERVICES DEPARTMENT The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided "as is" and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third -party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third -parry content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. https://asce7hazardtool.online/ Page 3 of 3 Fri Oct 08 2021 Blymyer Engineers, Inc. 1101 Marina Village Parkway, Suite 100, Alameda, CA 94501 C GIUMED P,dh•IV 2Q22 BLYMYER E N G I N E E R S Date 8/12/2021 By SG Client Ev90 Job No."CITYOFEDMONDS ES Chk Project 1200A Switchboard DEPARTMENT Variable Name Equation or Reference Symbl Value Unit Equipment Name J CG (X,Y,Z) C3 Z Y X h L2� 1200A Switchboard Width between anchors L2 21.0 in Length of unit L3 84.0 in Height of unit L4 91.5 in Center of gravity - Y CGy 46.0 in Weight Empty WE 2,131 lb Weight Full W 2,131 lb Number bolts in shear Ns 4 # Number bolts in tension Nt 2 # Short period spectral response' Sas 1.700 g Importance factor ASCE 7-16 § 13.1.3 Ip 1 - Component amplification ASCE 7-16 Tab. 13.6-1 ap 2.5 - Response modification factor ASCE 7-16 Tab. 13.6-1 RP 6 - Relative height in structure ASCE 7-16 § 13.3.1 z/h 0 - Overstrength factor ASCE 7-16 Tab. 13.6-1 Oo 2 - Nominal seismic coefficient .4 * ap * Sas * (1 + 2 * z/h) * Ip / RP Cs.nom 0.283 - Maximum seismic coefficient [EQ 13.3-2] = 1.6 * Sds * I — Cs.max 2.720 - Minimum seismic coefficient [EQ 13.3-3] = 0.3 * Sds * I = Cs.min 0.510 - Governing seismic coefficient Cs.min > Cs.nom < Cs.max = CS 0.510 - Total seismic load [EQ 13.3-1] = W * Cs= Fp 1,087 lb Ult seismic shear per anchor S)° * FP / Ns = VP' 543 lb Ult seismic tension per anchor ° p 9y 2 W*(0.9-.2*SaS)/2)/Nt= T " p 2,082 lb Height Above Ground Level z 15 ft Exposure Category ASCE 7-16 § 26.7.3 - C - Basic Wind speed ASCE 7-16 § 26.5.1 V 115 mph Velocity pressure exp. coefficient ASCE 7-16 Tab. 29.3-1 KZ 0.85 - Wind directionality factor ASCE 7-16 Tab. 26.6-1 Ka 0.85 - Topographic factor ASCE 7-16 Fig. 26.8-1 KZt 1 - Velocity pressure at elevation 0.00256 * KZ * Ka * KZt * VZ qZ 24.5 psf Guest effect factor ASCE 7-16 § 29.5 G 0.85 - Wind force coefficient ASCE 7-16 Fig. 29.5 Cf 1.3 - Wind load [ASCE § 29.51 qZ * G * Cf * L3 * L4 / 144 = Fes, 1,443 lb Ult wind shear per anchor F, / Ns Vw' 361 lb (FW*(L4/2)/L2-0.9WE/2)/Nt= Tw' 1,092 lb Refer to following for anchor bolt design check Blymyer Engineers, Inc. '- 1101 Marina Village Parkway, Suite 100, Alameda, CA 94501 B LY M Y E R Date 8/12/2021 Client E N G I N E E R S By SG Chk Project 1200A Switchboard Foundation design for: 1200A Switchboard Dimensions: B = 4.00 ft Foundation Width L = 8.00 ft Foundation Length T = 0.67 ft Foundation Thickness TE = 1.00 ft Foundation Edge Thickness CGy = 3.83 ft Seismic Center of Gravity L4= 7.63 ft Equipment Height \ ----- Loads: W, = 150xTxBxL = WE= W= VW = VP = SLIDING: Seismic: Wind: OVERTURNING: Seismic: Wind: BEARING: Seismic: if e' > B/3 if e' <_ B/3 Q <<= Wind: if e' > B/3 if e' <_ B/3 Q.1= 3,216 Lb Foundation Weight 2,131 Lb Equipment Weight Empty 2,131 Lb Equipment Weight Full 1,443 Lb Ultimate Wind Force 1,087 Lb Ultimate Seismic Force f = 0.25 CBC min allowable coefficient of friction p = 0 psf/ft lateral bearing pressure V = 0.7VP = 761 Lb VR = (W+W,)xf + pxLxTE2/2 = 1,337 Lb F.S. = VR/V= 1.8 >_ 1.5 O.K. V = 0.6VW = 866 Lb VR = (W+W,)xf + pxLxTE2/2 = 1,337 Lb F.S. = VR/V= 1.5 >_ 1.5 O.K. Mait = 0.7VPx(CGY+T) = 3,426 Lb-ft MR = (W+W,)x(B/2) = 10,694 Lb-ft F.S. = MR/Mait= 3.1 >_ 1.5 O.K. Moit= 0.6VWx(L4/2+T) = 3,880 Lb-ft MR= (WE+W,)x(B/2) = 10,694 Lb-ft F.S. = MR/Wit 2.8 >_ 1.5 O.K. Q = 1500 psf CBC min allowable bearing pressure e = Moit/(W+W,) = 0.64 ft e' = (B/2)-e = 1.36 ft > B/3 gmax= ((W+W,)/(BxL))±(Mortx6)/(B2xL) gmax= (W+W,)/(e'x3x0.5xL) gmax= 328 psf Qx1.333 = 2,000 psf ? gmax O.K. e = Moit/(WE+WJ = 0.73 ft e' = (B/2)-e = 1.27 ft <_ B/3 gmax= ((WE+W,)/(BxL))±(Mo/tx6)/(B2xL) gmax= (WE+W,)/(e'x3x0.5xL) gmax= 350 psf Qx1.333 = 2,000 psf ? gmax O.K. cog5CELVE D P 51, 11.872022 Job No. CITY OFEDMONDS VICES DEPARTMENT QxL By inspection reinforce with #5 bars @ 12" O.C., E.W. Hilti PROFIS Engineering 3.0.71 www.hilti.com RECEIVED Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Company: Page: 1 Address: Specifier: Phone I Fax: E-Mail: Design: 1200A Switch Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: Specifier's comments: 1 Input data Anchor type and diameter: Item number: Effective embedment depth: Material: Kwik Bolt TZ - SS 304 5/8 (3 1/8) not available hef,act = 3.125 in., hnom = 3.563 in. AISI 304 Evaluation Service Report: ESR-1917 Issued I Valid: 1/1/2020 1 5/1/2021 Proof: Design Method ACI 318-14 / Mech Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plate : IX x ly x t = 3.000 in. x 9.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) Profile: no profile Base material: cracked concrete, 2500, f� = 2,500 psi; h = 8.000 in. Installation: hammer drilled hole, Installation condition: Dry Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Note: the Kwik Bolt TZ - SS 304 anchor is in the process of phase -out. Application also possible with Kwik Bolt TZ2 - SS 304 under the selected boundary conditions. R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [in.] & Loading [Ib, in.Ib] Y X Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 0 RECEIVED Hilti PROFIS Engineering 3.0.71 www.hilti.com Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Company: Page: 2 Address: Specifier: Phone I Fax: E-Mail: Design: 1200A Switch Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 1.1 Design results Case Description Forces [lb] / Moments [in.lb] Seismic Max. Util. Anchor [%] Combination 1 N = 2,082; Vx = 543; Vy = 0 Mx = 0; My = 0; Mz = 0; Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan no 43 RECEIVED Jan 18 2022 Hilti PROFIS Engineering 3.0.71 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT www.hilti.com Company: Page: 3 Address: Specifier: Phone I Fax: E-Mail: Design: 1200A Switch Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity PN / Pv N Status Tension Concrete Breakout Failure 2,082 4,924 43 / - OK Shear Concrete edge failure in direction x+ 543 6,120 - / 9 OK Loading PN Pv t Utilization PN,y N Status Combined tension and shear loads 0.423 0.089 5/3 26 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 RECEIVED Jan 18 2022 Hilti PROFIS Engineering 3.0.71 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT www.hilti.com Company: Page: 4 Address: Specifier: Phone I Fax: E-Mail: Design: 1200A Switch Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Blymyer Engineers, Inc. 1101 Marina Village Parkway, Suite 100, Alameda, CA 94501 C GIUMED P,dh•IV 2Q22 BLYMYER E N G I N E E R S Date 8/12/2021 By SG Client EV90 Job No."CITYOFEDMONDS ES Chk Project Delta DC City Charger DEPARTMENT Variable Name Equation or Reference Symbl Value Unit Equipment Name J CG (X,Y,Z) C3 Z Y X h L2� Delta DC City Charger Width between anchors L2 16.5 in Length of unit L3 31.5 in Height of unit L4 59.1 in Center of gravity - Y CGy 30.0 in Weight Empty WE 772 lb Weight Full W 772 lb Number bolts in shear Ns 4 # Number bolts in tension Nt 2 # Short period spectral response' Sas 1.700 g Importance factor ASCE 7-16 § 13.1.3 Ip 1 - Component amplification ASCE 7-16 Tab. 13.6-1 ap 2.5 - Response modification factor ASCE 7-16 Tab. 13.6-1 RP 6 - Relative height in structure ASCE 7-16 § 13.3.1 z/h 0 - Overstrength factor ASCE 7-16 Tab. 13.6-1 Oo 2 - Nominal seismic coefficient .4 * ap * Sas * (1 + 2 * z/h) * Ip / RP Cs.nom 0.283 - Maximum seismic coefficient [EQ 13.3-2] = 1.6 * Sds * I — Cs.max 2.720 - Minimum seismic coefficient [EQ 13.3-3] = 0.3 * Sds * I = Cs.min 0.510 - Governing seismic coefficient Cs.min > Cs.nom < Cs.max = CS 0.510 - Total seismic load [EQ 13.3-1] = W * Cs= Fp 394 lb Ult seismic shear per anchor S)° * FP / Ns = VP' 197 lb Ult seismic tension per anchor ° p 9y 2 W*(0.9-.2*Sas)/2)/Nt= T " p 608 lb Height Above Ground Level z 15 ft Exposure Category ASCE 7-16 § 26.7.3 - C - Basic Wind speed ASCE 7-16 § 26.5.1 V 115 mph Velocity pressure exp. coefficient ASCE 7-16 Tab. 29.3-1 KZ 0.85 - Wind directionality factor ASCE 7-16 Tab. 26.6-1 Ka 0.85 - Topographic factor ASCE 7-16 Fig. 26.8-1 KZt 1 - Velocity pressure at elevation 0.00256 * KZ * Ka * KZt * VZ qZ 24.5 psf Guest effect factor ASCE 7-16 § 29.5 G 0.85 - Wind force coefficient ASCE 7-16 Fig. 29.5 Cf 1.3 - Wind load [ASCE § 29.51 qZ * G * Cf * L3 * L4 / 144 = Fes, 349 lb Ult wind shear per anchor F, / Ns Vw' 87 lb (FW*(L4/2)/L2-0.9WE/2)/Nt= Tw' 139 lb Refer to following for anchor bolt design check '' Blymyer Engineers, Inc. CAEC drll;ED '— 1101 Marina Village Parkway, Suite 100, Alameda, CA 94501 P 5Jar$2I1832M2 B LY M Y E R Date 8/12/2021 Client ,loll No. CITY OFEDMONDS ICES E N G I N E E R S By SG Chk Project Delta DC City Charger DEPARTMENT Foundation design for: Delta DC City Charger Dimensions: B = 2.33 ft Foundation Width L = 3.00 ft Foundation Length T = 1.42 ft Foundation Thickness TE = 0.75 ft Foundation Edge Thickness CGy = 2.50 ft Seismic Center of Gravity L4= 4.93 ft Equipment Height Loads: WO = l50xTxBxL = 1,489 Lb Foundation Weight WE = 772 Lb Equipment Weight Empty W = 772 Lb Equipment Weight Full VW = 349 Lb Ultimate Wind Force VP = 394 Lb Ultimate Seismic Force SLIDING: f = 0.25 CBC min allowable coefficient of friction p = 0 psf/ft lateral bearing pressure Seismic: V = 0.7VP = 276 Lb VR = (W+WO)xf + pxLxTE2/2 = 565 Lb F.S. = VR/V= 2.1 >_ 1.5 O.K. Wind: V = 0.6VW = 210 Lb VR = (W+WO)xf + pxLxTE2/2 = 565 Lb F.S. = VR/V= 2.7 >_ 1.5 O.K. OVERTURNING: Seismic: Ma/t= 0.7VPx(CGy+T) = 1,080 Lb-ft MR = (W+WO)x(B/2) = 2,634 Lb-ft F.S. = MR/MO/t= 2.4 >_ 1.5 O.K. Wind: MO/t= 0.6VWx(L4/2+T) = 814 Lb-ft MR= (WE+WO)x(B/2) = 2,634 Lb-ft F.S. = MR/MO/t= 3.2 >_ 1.5 O.K. BEARING: Q = 1500 psf CBC min allowable bearing pressure Seismic: e = MO/t/(W+WO) = 0.48 ft e' = (B/2)-e = 0.69 ft <_ B/3 if e' > B/3 gmax= ((W+WO)/(BxL))±(MO/tx6)/(B2xL) if e' <_ B/3 gmax= (W+WO)/(e'x3x0.5xL) gmax= 731 psf Q,,= Qx1.333 = 2,000 psf gmax O.K. Wind: e = MO/t/(WE+WO) = 0.36 ft e' _ (B/2)-e = 0.80 ft > B/3 if e' > B/3 gmax= ((WE+WO)/(BxL))±(MO/tx6)/(B2xL) if e' <_ B/3 gmax= (WE+WO)/(e'x3x0.5xL) gmax= 623 psf Q,,= Qx1.333 = 2,000 psf gmax O.K. By inspection reinforce with #5 bars @ 12" O.C., E.W. Hilti PROFIS Engineering 3.0.71 www.hilti.com RECEIVED Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Company: Page: 1 Address: Specifier: Phone I Fax: E-Mail: Design: Delta City Sds:1.7 Wind:115mph Date: 8/12/2021 Fastening point: Specifier's comments: 1 Input data Anchor type and diameter: Item number: Effective embedment depth: Material: Evaluation Service Report: Issued I Valid: Proof: Stand-off installation: Profile: Base material: Installation: Reinforcement: Kwik Bolt TZ - SS 304 1/2 (3 1/4) not available hef,act - 3.250 in., hnom = 3.625 in. AISI 304 ESR-1917 1/1/2020 1 5/1/2021 Design Method ACI 318-14 / Mech cracked concrete, 2500, f� = 2,500 psi; h = 17.000 in. hammer drilled hole, Installation condition: Dry tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Note: the Kwik Bolt TZ - SS 304 anchor is in the process of phase -out. Application also possible with Kwik Bolt TZ2 - SS 304 under the selected boundary conditions. Geometry [in.] & Loading [lb, in.lb] r r�0 X Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 0 RECEIVED Hilti PROFIS Engineering 3.0.71 www.hilti.com Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Company: Page: 2 Address: Specifier: Phone I Fax: E-Mail: Design: Delta City Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 1.1 Design results Case Description Forces [lb] / Moments [in.lb] Seismic Max. Util. Anchor [%] 1 Combination 1 N = 608; V. = 197; Vy = 0; no 24 Mx = 0; My = 0; MZ = 0; Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan RECEIVED Jan 18 2022 Hilti PROFIS Engineering 3.0.71 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT www.hilti.com Company: Page: 3 Address: Specifier: Phone I Fax: E-Mail: Design: Delta City Sds:1.7 Wind:115mph Date: 8/12/2021 Fastening point: 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity PIN / Pv N Status Tension Concrete Breakout Failure 608 2,545 24 / - OK Shear Concrete edge failure in direction x+ 197 2,006 410 10 OK Loading PN Pv C Utilization PN,y N Status Combined tension and shear loads 0.239 0.098 5/3 12 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 RECEIVED Jan 18 2022 Hilti PROFIS Engineering 3.0.71 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT www.hilti.com Company: Page: 4 Address: Specifier: Phone I Fax: E-Mail: Design: Delta City Sds:1.7 Wind:115mph Date: 8/12/2021 Fastening point: 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Blymyer Engineers, Inc. 1101 Marina Village Parkway, Suite 100, Alameda, CA 94501 C GIUMED P,dh•IV 2Q22 BLYMYER E N G I N E E R S Date 8/12/2021 By SG Client EV90 Job No."CITYOFEDMONDS ES Chk Project Delta 350 Dispenser DEPARTMENT Variable Name Equation or Reference Symbl Value Unit Equipment Name J CG (X,Y,Z) C3 Z Y X h L2� Delta 350 Dispenser Width between anchors L2 11.3 in Length of unit L3 26.0 in Height of unit L4 79.0 in Center of gravity - Y CGy 40.0 in Weight Empty WE 530 lb Weight Full W 530 lb Number bolts in shear Ns 4 # Number bolts in tension Nt 2 # Short period spectral response' Sas 1.700 g Importance factor ASCE 7-16 § 13.1.3 Ip 1 - Component amplification ASCE 7-16 Tab. 13.6-1 ap 2.5 - Response modification factor ASCE 7-16 Tab. 13.6-1 RP 6 - Relative height in structure ASCE 7-16 § 13.3.1 z/h 0 - Overstrength factor ASCE 7-16 Tab. 13.6-1 Oo 2 - Nominal seismic coefficient .4 * ap * Sas * (1 + 2 * z/h) * Ip / RP Cs.nom 0.283 - Maximum seismic coefficient [EQ 13.3-2] = 1.6 * Sds * I — Cs.max 2.720 - Minimum seismic coefficient [EQ 13.3-3] = 0.3 * Sds * I = Cs.min 0.510 - Governing seismic coefficient Cs.min > Cs.nom < Cs.max = CS 0.510 - Total seismic load [EQ 13.3-1] = W * Cs= Fp 270 lb Ult seismic shear per anchor S)° * FP / Ns = VP' 135 lb Ult seismic tension per anchor ° p 9y 2 W*(0.9-.2*Sas)/2)/Nt= T " p 883 lb Height Above Ground Level z 15 ft Exposure Category ASCE 7-16 § 26.7.3 - C - Basic Wind speed ASCE 7-16 § 26.5.1 V 115 mph Velocity pressure exp. coefficient ASCE 7-16 Tab. 29.3-1 KZ 0.85 - Wind directionality factor ASCE 7-16 Tab. 26.6-1 Ka 0.85 - Topographic factor ASCE 7-16 Fig. 26.8-1 KZt 1 - Velocity pressure at elevation 0.00256 * KZ * Ka * KZt * VZ qZ 24.5 psf Guest effect factor ASCE 7-16 § 29.5 G 0.85 - Wind force coefficient ASCE 7-16 Fig. 29.5 Cf 1.3 - Wind load [ASCE § 29.51 qZ * G * Cf * L3 * L4 / 144 = Fes, 386 lb Ult wind shear per anchor F, / Ns Vw' 96 lb (FW*(L4/2)/L2-0.9WE/2)/Nt= Tw' 555 lb Refer to following for anchor bolt design check Blymyer Engineers, Inc. CAEC drll;ED '' '— 1101 Marina Village Parkway, Suite 100, Alameda, CA 94501 P 5Jar$2I1832M2 Date 8/12/2021 Client ,loll No. CITY OFEDMONDS B LY M Y E R ICES E N G I N E E R S By SG Chk Project Delta 350 Dispenser DEPARTMENT Foundation design for: Delta 350 Dispenser Dimensions: B = 3.25 ft Foundation Width L = 4.41 ft Foundation Length T = 1.75 ft Foundation Thickness v TE = 1.00 ft Foundation Edge Thickness CGy = 3.33 ft Seismic Center of Gravity L4= 6.58 ft Equipment Height Loads: T WO = l50xTxBxL = 3,762 Lb Foundation Weight w WE = 530 Lb Equipment Weight Empty W = 530 Lb Equipment Weight Full j3 L VW = 386 Lb Ultimate Wind Force VP = 270 Lb Ultimate Seismic Force SLIDING: f = 0.25 CBC min allowable coefficient of friction p = 0 psf/ft lateral bearing pressure Seismic: V = 0.7VP = 189 Lb VR = (W+WO)xf + pxLxTE2/2 = 1,073 Lb F.S. = VR/V= 5.7 >_ 1.5 O.K. Wind: V = 0.6VW = 231 Lb VR = (W+WO)xf + pxLxTE2/2 = 1,073 Lb F.S. = VR/V= 4.6 >_ 1.5 O.K. OVERTURNING: Seismic: MO/t = 0.7VPx(CGy+T) = 962 Lb-ft MR = (W+WO)x(B/2) = 6,975 Lb-ft F.S. = MR/MO/t= 7.3 >_ 1.5 O.K. Wind: Mo/t= 0.6VWx(L4/2+T) = 1,166 Lb-ft MR= (WE+W,)x(B/2) = 6,975 Lb-ft F.S. = MR/MO/t= 6.0 >_ 1.5 O.K. BEARING: Q = 1500 psf CBC min allowable bearing pressure Seismic: e = Mo/t/(W+WO) = 0.22 ft e' = (B/2)-e = 1.40 ft > B/3 If e' > B/3 gmax= ((W+W,)/(BxL))±(MO/tx6)/(B2xL) if e' <_ B/3 gmax= (W+WO)/(e'x3x0.5xL) gmax= 423 psf Q,,= Qx1.333 = 2,000 psf gmax O.K. Wind: e = MOR/(WE+WO) = 0.27 ft e' _ (B/2)-e = 1.35 ft > B/3 if e' > B/3 gmax= ((WE+WO)/(BxL))±(MO/tx6)/(B2xL) if e' <_ B/3 gmax= (WE+WO)/(e'x3x0.5xL) gmax= 450 psf Q,,= Qx1.333 = 2,000 psf gmax O.K. By inspection reinforce with #5 bars @ 12" O.C., E.W. Hilti PROFIS Engineering 3.0.71 www.hilti.com RECEIVED Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Company: Page: 1 Address: Specifier: Phone I Fax: E-Mail: Design: Delta350 Dis Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: Specifier's comments: 1 Input data Anchor type and diameter: Item number: Effective embedment depth: Material: Evaluation Service Report: Issued I Valid: Proof: Stand-off installation: Profile: Base material: Installation: Reinforcement: Kwik Bolt TZ - SS 304 1/2 (3 1/4) not available hef,act - 3.250 in., hnom = 3.625 in. AISI 304 ESR-1917 1/1/2020 1 5/1/2021 Design Method ACI 318-14 / Mech cracked concrete, 2500, f� = 2,500 psi; h = 21.000 in. hammer drilled hole, Installation condition: Dry tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Note: the Kwik Bolt TZ - SS 304 anchor is in the process of phase -out. Application also possible with Kwik Bolt TZ2 - SS 304 under the selected boundary conditions. Geometry [in.] & Loading [lb, in.lb] .. X Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 0 RECEIVED Hilti PROFIS Engineering 3.0.71 www.hilti.com Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Company: Page: 2 Address: Specifier: Phone I Fax: E-Mail: Design: Delta350 Dis Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 1.1 Design results Case Description Forces [lb] / Moments [in.lb] Seismic Max. Util. Anchor [%] Combination 1 N = 883; Vx = 135; Vy = 0; Mx = 0; My = 0; Mz = 0; Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan no 28 RECEIVED Jan 18 2022 Hilti PROFIS Engineering 3.0.71 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT www.hilti.com Company: Page: 3 Address: Specifier: Phone I Fax: E-Mail: Design: Delta350 Dis Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity PN / Pv N Status Tension Concrete Breakout Failure 883 3,237 28 / - OK Shear Steel Strength 135 4,472 - / 4 OK Loading PN Pv t Utilization PN,y N Status Combined tension and shear loads 0.273 0.030 5/3 12 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 RECEIVED Jan 18 2022 Hilti PROFIS Engineering 3.0.71 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT www.hilti.com Company: Page: 4 Address: Specifier: Phone I Fax: E-Mail: Design: Delta350 Dis Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Blymyer Engineers, Inc. 1101 Marina Village Parkway, Suite 100, Alameda, CA 94501 C GIUMED P,dh•IV 2Q22 BLYMYER E N G I N E E R S Date 8/12/2021 By SG Client EV90 Job No."CITYOFEDMONDS ES Chk Project Delta Power Cabinet DEPARTMENT Variable Name Equation or Reference Symbl Value Unit Equipment Name J CG (X,Y,Z) C3 Z Y X h L2� Delta Power Cabinet Width between anchors L2 26.6 in Length of unit L3 39.3 in Height of unit L4 78.7 in Center of gravity - Y CGy 40.0 in Weight Empty WE 1,356 lb Weight Full W 1,356 lb Number bolts in shear Ns 4 # Number bolts in tension Nt 2 # Short period spectral response' Sas 1.700 g Importance factor ASCE 7-16 § 13.1.3 Ip 1 - Component amplification ASCE 7-16 Tab. 13.6-1 ap 2.5 - Response modification factor ASCE 7-16 Tab. 13.6-1 RP 6 - Relative height in structure ASCE 7-16 § 13.3.1 z/h 0 - Overstrength factor ASCE 7-16 Tab. 13.6-1 Oo 2 - Nominal seismic coefficient .4 * ap * Sas * (1 + 2 * z/h) * Ip / RP Cs.nom 0.283 - Maximum seismic coefficient [EQ 13.3-2] = 1.6 * Sds * I — Cs.max 2.720 - Minimum seismic coefficient [EQ 13.3-3] = 0.3 * Sds * I = Cs.min 0.510 - Governing seismic coefficient Cs.min > Cs.nom < Cs.max = CS 0.510 - Total seismic load [EQ 13.3-1] = W * Cs= Fp 692 lb Ult seismic shear per anchor S)° * FP / Ns = VP' 346 lb Ult seismic tension per anchor ° p 9y 2 W*(0.9-.2*Sas)/2)/Nt= T " p 850 lb Height Above Ground Level z 15 ft Exposure Category ASCE 7-16 § 26.7.3 - C - Basic Wind speed ASCE 7-16 § 26.5.1 V 115 mph Velocity pressure exp. coefficient ASCE 7-16 Tab. 29.3-1 KZ 0.85 - Wind directionality factor ASCE 7-16 Tab. 26.6-1 Ka 0.85 - Topographic factor ASCE 7-16 Fig. 26.8-1 KZt 1 - Velocity pressure at elevation 0.00256 * KZ * Ka * KZt * VZ qZ 24.5 psf Guest effect factor ASCE 7-16 § 29.5 G 0.85 - Wind force coefficient ASCE 7-16 Fig. 29.5 Cf 1.3 - Wind load [ASCE § 29.51 qZ * G * Cf * L3 * L4 / 144 = Fes, 581 lb Ult wind shear per anchor F, / Ns Vw' 145 lb (FW*(L4/2)/L2-0.9WE/2)/Nt= Tw' 124 lb Refer to following for anchor bolt design check '' Blymyer Engineers, Inc. '— 1101 Marina Village Parkway, Suite 100, Alameda, CA 94501 B LY M Y E R Date 8/12/2021 Client E N G I N E E R S By SG Chk Project Delta Power Cabinet Foundation design for: Delta Power Cabinet nimansionG- B= L= T= TE _ CGy = L4 = Loads: W, = l50xTxBxL = WE— W= VW = VP = SLIDING: Seismic: Wind: OVERTURNING: Seismic: Wind: BEARING: Seismic: if e' > B/3 if e' <_ B/3 Q"= Wind: if e' > B/3 if e' <_ B/3 Q"= 4.00 ft Foundation Width 4.00 ft Foundation Length 0.67 ft Foundation Thickness 1.00 ft Foundation Edge Thickness 3.33 ft Seismic Center of Gravity 6.56 ft Equipment Height —�- --- ---- - I� 1,608 Lb Foundation Weight 1,356 Lb Equipment Weight Empty 1,356 Lb Equipment Weight Full 581 Lb Ultimate Wind Force 692 Lb Ultimate Seismic Force f = 0.25 CBC min allowable coefficient of friction p = 0 psf/ft lateral bearing pressure V = 0.7VP = 484 Lb VR = (W+W,)xf + pxLxTE2/2 = 741 Lb F.S. = VR/V = 1.5 >— 1.5 O.K. V = 0.6VW = 348 Lb VR = (W+W,)xf + pxLxTE2/2 = 741 Lb F.S. = VR/V = 2.1 >_ 1.5 O.K. Man= 0.7VPx(CGY+T) = 1,938 Lb-ft MR = (W+W,)x(B/2) = 5,928 Lb-ft F.S. = MR/Ma/t= 3.1 >_ 1.5 O.K. Mat= 0.6VWx(L4/2+T) = 1,376 Lb-ft MR= (WE+W,)x(B/2) = 5,928 Lb-ft F.S. = MR/Ma/t= 4.3 >— 1.5 O.K. 1500 psf CBC min allowable bearing pressure e = Mat/(W+W,) = 0.65 ft e' = (B/2)-e = 1.35 ft > B/3 gmax= ((W+W(;)/(BxL))±(Mo/tx6)/(B2xL) gmax= (W+W,)/(e'x3x0.5xL) gmax= 367 psf Qx1.333 = 2,000 psf ? gmax O.K. e = Mat/(WE+W J = 0.46 ft e'= (B/2)-e = 1.54 ft > B/3 gmax= ((WE+W,)/(BxL))+(Monx6)/(B2xL) gmax= (WE+W(;)/(e'x3x0.5xL) gmax= 314 psf Qx1.333 = 2,000 psf ? gmax O.K. CORACENED P 5Jar$2I1832M2 Job No. CITY OF EDMONDS ICES DEPARTMENT QxL By inspection reinforce with #5 bars @ 12" O.C., E.W. Hilti PROFIS Engineering 3.0.71 www.hilti.com RECEIVED Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Company: Page: 1 Address: Specifier: Phone I Fax: E-Mail: Design: Delta350 Cab Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: Specifier's comments: 1 Input data Anchor type and diameter: Item number: Effective embedment depth: Material: Evaluation Service Report: Issued I Valid: Proof: Stand-off installation: Profile: Base material: Installation: Reinforcement: Kwik Bolt TZ - SS 304 1/2 (3 1/4) not available hef,act - 3.250 in., hnom = 3.625 in. AISI 304 ESR-1917 1/1/2020 1 5/1/2021 Design Method ACI 318-14 / Mech cracked concrete, 2500, f� = 2,500 psi; h = 8.000 in. hammer drilled hole, Installation condition: Dry tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Note: the Kwik Bolt TZ - SS 304 anchor is in the process of phase -out. Application also possible with Kwik Bolt TZ2 - SS 304 under the selected boundary conditions. Geometry [in.] & Loading [lb, in.lb] Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 0 RECEIVED Hilti PROFIS Engineering 3.0.71 www.hilti.com Jan 18 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Company: Page: 2 Address: Specifier: Phone I Fax: E-Mail: Design: Delta350 Cab Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 1.1 Design results Case Description Forces [lb] / Moments [in.lb] Seismic Max. Util. Anchor [%] Combination 1 N = 850; Vx = 346; Vy = 0; Mx = 0; My = 0; Mz = 0; Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan no 27 RECEIVED Jan 18 2022 Hilti PROFIS Engineering 3.0.71 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT www.hilti.com Company: Page: 3 Address: Specifier: Phone I Fax: E-Mail: Design: Delta350 Cab Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity PIN / Pv N Status Tension Concrete Breakout Failure 850 3,237 27 / - OK Shear Concrete edge failure in direction x+ 346 3,490 410 10 OK Loading PN Pv C Utilization PN,y N Status Combined tension and shear loads 0.263 0.099 5/3 13 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 RECEIVED Jan 18 2022 Hilti PROFIS Engineering 3.0.71 CITY OFEDMONDS DEVELOPMENT SERVICES DEPARTMENT www.hilti.com Company: Page: 4 Address: Specifier: Phone I Fax: E-Mail: Design: Delta350 Cab Sds:1.7 Wind: 115mph Date: 8/12/2021 Fastening point: 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROMS Engineering ( c ) 2003-2021 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan