APPROVED BLD-RESUB 1-Architectural_Plan+5.18.202214'-6"
\
BEDROOM
5'
N
H CLOSET
32'
� a2 �
5' 15'-8" 7' 6-1 1/2"
1 ' 6"
2' S' _7'-8" 6' 2' 2-F 2'-6" 2' 8" 2'-6"
DD D NEW WINDOW5 / 4 X 10 D/F#2 HDR
8050T5 6068� 2636DH 2636DH
FAN/HEAT/LIGHT o
I D O Ir
} Ns /
D Leim O�W �_ /
(Yi 50 GFM VTO m m — - /
DINTERIOR BRACED WALL 46 BATH g Q ® O
2468
AREA OF
BATH ZEE INTERIOR BRACED WALL LAUNDRY ROOM FAN / HEAT / LIGHT E 1 /
LA N REMOVED REMOVE EXI5TING WALL FOR 50 GFM VTO �p
/ RELOCATED HALLWAY ACCE55 cn HALL ois LAUNDRY P-1
ELEVATION 1
LIVING ROOM m /
\ CLOS11
ET INTERIOR NON -BEARING WALL5 TO BE REMOVED
2665 2b 26b8— — — — — — — —
/ \ RIDGE
CA I r \ CA
EXISTING 5FR
ATTIC
10'-8 1/2"
2'-11 1/2"
--- ------ 3068 /
N �
m
N r p FRIDGE SELF CLOSING 20 MIN FIRE DOOR / 5/8" TYPE "X" DRYWALL @ ALL NEW WALL5
-- FRIDGE --- --
LL cn NI I
Z N I _ �� I LANDING
� N I I m
w VTO
Aa
/ / \
KITCHEN I � m
—__— __-- ca
GARAGE \
D15HWA5HER 1 5B36 633 T
A I\
4034FX / \
H15 OUT5IDE WALL I //
�- - - - - - - - - - - - - - - - - - ---
4' 5'-4" 4' 16, 4' —
24'
FLOOR PLAN SCALE 1 /411 = 1 '
TYPICAL ROOF CONSTRUCTION
ASPHALT COMP. ROOFING
#15 FELT PAPER
1/2" APA - RATED SHEATHING OVER
MANUF. TRUSSES @ 24" O/C
5/8'. G.W.B.
PROP05ED NEW BATH /LAUNDRY
W
II II II
R21 INSULATED 2 X 6 WALL
WITH STUDS @ 16" O/C TYP.
TYP. INTERIOR WALL CONSTRUCTION
2 X 4 STUDS @ 16" O/C WITH DOUBLE TOP PLATE
AND G.W.B. EACH SIDE
GARAGE
TYP. FLOOR CONSTRUCTION SLAB
IL 4" CONCRETE FINISNED FLOOR OVER
COMPACTED FILL
nnnnnnnnnnnnnnnnnnnnnnnnnnnnn RIGID FOAM INSULATION TYP.
12 X 8 PT J015T OVER 4" CONCRETE FLOOR ANCHORED" 1/4" X 4" QUICK BOLTS (GALV.)
E-1 OR055 5EOTION SCALE 3/8" = 1'
co
1
I FASTENERS FOR PRESERVATIVE -TREATED AND !
.FIRE -RETARDANT -TREATED WOOD SHALL BE OF HOT -DIPPED
!ZINC -COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE !
.OR COPPER. COATING WEIGHTS FOR ZINC -COATED FASTENERS SHALL BE,
! IN ACCORDANCE WITH ASTM A153, IBC SECTION 2304.10.5 & IRC SECTION !
■ 317.3
24'
S LEDGER ATTACHED TO EXISTING CONCRETE / FRAMING
U5E 316" X 4.5 GALV. EXPAN51011 BOLTS OR LA65 TO WOOD
A5 NEEDED @ 12" O/G 5TAGGERED 2" FROM BOTTOM AND TOP OF LEDGER - - - - -
- - - - - -
I
I
I
E1
P-1 I
ELEVATION 1 I I
I I
I I
I 2 X 8 PT J015T @ 16" W/ RIGID INSULATION I I
. � I DIRECT ONTO EXISTING CONCRETE FLOOR I
I I
I I
1
�I I
I
I I
� I
L-----------------------�
..
—
— — — — — — — — — — — —
— — — — — — — — — — — —
—
24'
24'
SEPARATE PLUMBING OBTAIN ELECTRICAL
PERMIT REQUIRED FOR PERMIT FROM
STATE LABOR &
THIS PROJECT. �� _ �
INDUSTRIES FLOOR FRAMING PLAN 5CAL E 1 /4 - 1
HIGHEST RIDGE
11.8'
TOP OF PLATE
q.1'
APPROVED
PLANS MUST BE
ON JOB SITE
City of Edmonds
Building Department
APPROVED Plans
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
City Of Edmonds
Building Department
------------------
Work INTERIOR REMODEL
Address; 21925 95TH AVE W
-----------------------------------
------------------------------------
Owner ; LLETTE - ------------ --
Approved Date; 6'2r2C�22 /
Building Official:
Permit Number;
----------- -----------
BLD2022-0532---------------------------------------------
TOP OF 5UBFLOOR - 15T FLOOR
0'
TOP OF 5UBFLOOR - FOUNDATION
-1.11
BOTTOM OF FOOTING
-4 ff
WALL LEGEND
EXISTING WALL TO BE REMOVED C _ _ _ _ _
EXISTING WALL TO BE REMAIN
PROPOSED NEW INTERIOR WALL
PROPOSED NEW EXTERIOR WALL
LATERAL CONTROL (PRE5CRIPTI\/E)
WALL BRACING PANEL SCHEDULE
A. PLYWOOD / OSB 6d NAIL 6" O.C. ( EDGES )
3/8" X 4' X 8' 12" O.C. (FIELD)
B. GWB - 1/2" X 4' X 8' 5d COLLIER / WALLBOARD NAILS
( ONE FACE) *7 O.C.
C. GWB - 1/2" X 4' X 8' 5d COLLIER / WALLBOARD NAILS
( TWO FACES) *7 O.C. THROUGHOUT
D. STRUCTURAL PANEL SIDING CORROSION -RESISTANT 6d NAILS
* 6" O.C. (EDGES)
3/8" X 4' X 8' *12" O.C. (FIELD)
NAILING 8d * 6" O.C. ( EDGES )
* 12" O.C. (FIELD)
E. ONE - STORY ALT. BRACE PANEL BLOCKING REQ. AT ALL EDGES
3/8" X 2'-8" X 10' OR LESS ANCHOR BOLTS - 2 EA.
PLACED AT QUATER POINTS
HOLDDOWNS - 1800# AT
NAILING 8d * 6" O.C. ( EDGES )
F. TWO-STORY ALT. BRACE PANEL * 12" O.C. (FIELD)
3/8" X 2'-8" X 10' OR LESS BLOCKING REQ. AT ALL EDGES
PLYWOOD OR OSB ( TWO FACES) ANCHOR BOLTS - 3 EA.
PLACED AT FIFTH POINTS
HOLDDOWNS - 3500# AT
GENERAL NOTES:
1. BRACED WALL PANEL SOLE PLATES NAILED TO FLOOR AND
TOP PLATES SHALL BE ANCHORED TO FRAMING ABOVE
2.
WHERE JOINTS ARE PERPENDICULAR TO BRACED WALL
LINES, PROVIDE BLOCKING UNDER AND IN LINE WITH BRACED
WALL PANELS
RESUB
May 18 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
TOP OF 5UBFLOOR - 15T FLOOR
0'
TOP OF 5UBFLOOR - FOUNDATION
-1.11
BOTTOM OF FOOTING
-4 ff
WALL LEGEND
EXISTING WALL TO BE REMOVED C _ _ _ _ _
EXISTING WALL TO BE REMAIN
PROPOSED NEW INTERIOR WALL
PROPOSED NEW EXTERIOR WALL
LATERAL CONTROL (PRE5CRIPTI\/E)
WALL BRACING PANEL SCHEDULE
A. PLYWOOD / OSB 6d NAIL 6" O.C. ( EDGES )
3/8" X 4' X 8' 12" O.C. (FIELD)
B. GWB - 1/2" X 4' X 8' 5d COLLIER / WALLBOARD NAILS
( ONE FACE) *7 O.C.
C. GWB - 1/2" X 4' X 8' 5d COLLIER / WALLBOARD NAILS
( TWO FACES) *7 O.C. THROUGHOUT
D. STRUCTURAL PANEL SIDING CORROSION -RESISTANT 6d NAILS
* 6" O.C. (EDGES)
3/8" X 4' X 8' *12" O.C. (FIELD)
NAILING 8d * 6" O.C. ( EDGES )
* 12" O.C. (FIELD)
E. ONE - STORY ALT. BRACE PANEL BLOCKING REQ. AT ALL EDGES
3/8" X 2'-8" X 10' OR LESS ANCHOR BOLTS - 2 EA.
PLACED AT QUATER POINTS
HOLDDOWNS - 1800# AT
NAILING 8d * 6" O.C. ( EDGES )
F. TWO-STORY ALT. BRACE PANEL * 12" O.C. (FIELD)
3/8" X 2'-8" X 10' OR LESS BLOCKING REQ. AT ALL EDGES
PLYWOOD OR OSB ( TWO FACES) ANCHOR BOLTS - 3 EA.
PLACED AT FIFTH POINTS
HOLDDOWNS - 3500# AT
GENERAL NOTES:
1. BRACED WALL PANEL SOLE PLATES NAILED TO FLOOR AND
TOP PLATES SHALL BE ANCHORED TO FRAMING ABOVE
2.
WHERE JOINTS ARE PERPENDICULAR TO BRACED WALL
LINES, PROVIDE BLOCKING UNDER AND IN LINE WITH BRACED
WALL PANELS
RESUB
May 18 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
RESUB
May 18 2022
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
z
O
d
W
J
m
m
Q
Q
W
z�
O
co
IYW
W
lY
W
W
m
z
CO
~�
O
�
Ln Q
Z
Ln SO
Q
(V LIA
z �
AO
z�
oQ
aQ
ua <
\Q
LU z
LU 111
Q
O
O�
LULL
LU
CID
o LU
LUQ
0 N
0 l� LU
z
Z CD
Q
0
DATE:
5/18/2022
SCALE:
SHEET:
P-1
o
L
LU
co
2018 Washington State Energy Code - Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family - New & Additions effective February 1, 2021 Version 1.1
These requirements apply to all IRC building types, including detached one- and two-family
dwellings and multiple single-family dwellings (townhouses).
Project Information Contact Information
EDMONDS TERRY WILLEY
Instructions: This single-family project will use the requirements of the Prescriptive Path below and
incorporate the minimum values listed. Based on the size of the structure, the appropriate number of
additional credits are checked as chosen by the permit applicant.
Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and
Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits.
Authorized Representative FDate 05/18/2022
All Climate Zones Table R402.1.1
R-Value,
U-Factora
Fenestration U-Factor b
n/a
0.30
Skylight U-Factor b
n/a
0.50
Glazed Fenestration SHGC bje
n/a
n/a
Ceiling a
49
0.026
Wood Frame Wall g•h
21 int
0.056
Floor
30
0.029
Below Grade Wall c h
10/15/21 int + TB
0.042
Slab d•f R-Value & Depth
1 10, 2 ft
n/a
R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less
a
than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix
Table A101.4 shall not be less than the R-value specified in the table.
The fenestration U-factor column excludes skylights.
b
"10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on
the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at
c
the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on
the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB"
means R-5 thermal break between floor slab and basement wall.
d
R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1.
For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth
e
extends over the top plate of the exterior wall.
R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter
f
slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall
meet the requirements for thermal barriers protecting foam plastics.
For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for
g
climate zone 5 of ICC 400.
Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard
h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10
insulation.
Prescriptive Path - Single Family
••.
ACT"
2018 Washington State Energy Code-R
2018 Washington State Energy Code - Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family - New & Additions (effective February 1, 2021)
Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel
normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of
credits. To claim this credit, the building permit drawings shall specify the option selected and the
maximum tested building air leakage, and show the qualifying ventilation system and its control sequence
of operation.
1. Small Dwelling Unit: 3 credits
Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area.
Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf.
2. Medium Dwelling Unit: 6 credits
All dwelling units that are not included in #1 or #3
3. Large Dwelling Unit: 7 credits
Dwelling units exceeding 5,000 sf of conditioned floor area
4. Additions less than 500 square feet: 1.5 credits
All other additions shall meet 1-3 above
Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4.
Summary of Table R406.2 and 406.3
Heating Credits - select ONE
Options Fuel Normalization Descriptions heating option User Notes
1 Combustion heating minimum NAECAb 0.0 ❑
2 Heat pump` 1.0 0 EXISTING
3
Electric resistance heat only - furnace or zonal
-1.0 ❑
0.5 ❑
-1.0 ❑
Credits - select ONE
energy option from each
-ate ory
0.5 0
4
DHP with zonal electric resistance per option 3.4
All other heating systems
Energy Credit Option Descriptions
Efficient Building Envelope
Efficient Building Envelope
5
Energy
O tions
p
1.1
1.2
1.0
0.5
1.0
❑
❑
❑
1.3
Efficient Building Envelope
1.4
Efficient Building Envelope
1.5
Efficient Building Envelope
2.0
❑
1.6
Efficient Building Envelope
3.0
❑
1.7
Efficient Building Envelope
0.5
❑
2.1
Air Leakage Control and Efficient Ventilation
0.5
❑
2.2
Air Leakage Control and Efficient Ventilation
1.0
❑
2.3
Air Leakage Control and Efficient Ventilation
1.5
❑
2.4
Air Leakage Control and Efficient Ventilation
2.0
❑
❑
❑
❑
❑
❑
❑
❑
❑
3.1a
High Efficiency HVAC
1.0
3.2
High Efficiency HVAC
1.0
3.31
High Efficiency HVAC
1.5
3.4
High Efficiency HVAC
1.5
3.5
High Efficiency HVAC
1.5
3.6'
High Efficiency HVAC
2.0
4.1
High Efficiency HVAC Distribution System
0.5
4.2
High Efficiency HVAC Distribution System
1.0
1 Prescriptive Path -Single Family 2018 Washington State Energy Code-R
2018 Washington State Energy Code - Residential
Prescriptive Energy Code Compliance for All Climate Zones in Washington
Single Family - New & Additions (effective February 1, 2021)
Summary of Table R406.2 (cont.)
Energy
Options
Energy Credit Option Descriptions (cont.)
Credits - select ONE
energy option from
each category d
User Notes
5. Id
Efficient Water Heating
0.5
❑
5.2
0.5
❑
Efficient Water Heating
5.3
1.0
❑
Efficient Water Heating
5.4
1.5
❑
Efficient Water Heating
5.5
Efficient Water Heating
2.0
❑
Efficient Water Heating
2.5
5.6
❑
6.1e
Renewable Electric Energy (3 credits max)
1.0
Q
7.1
Appliance Package
0.5
❑
Total Credits
1.5
,'--late Total
clear Form
a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W,
whichever is bigger, may be installed in the dwelling unit.
b. Equipment listed in Table C403.3.2(4) or C403.3.2(5)
c. Equipment listed in Table C403.3.2(1) or C403.3.2(2)
d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined
with options 5.2 through 5.6. See Table 406.3.
e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max.
See the complete Table R406.2 for all requirements and option
descriptions.
f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group.
Please print only pages 1 through 3 of this worksheet for submission to your building official.
For Building Officials Only
Prescriptive Path - Single Family
Monsoon I has taken the one-piece
ing surface. Equipped with 6-speed ZE PI-1'R • • ZE PH R
liner to the next level. Including
electronic controls, pro baffle filters,
dual -level LumiLight LED's and an
our exclusive ACTTm technology and ZEPHYRONLINE.COM ZEPHYRONLINE.COM
ADA-compliant wireless remote you
either a powerful 600-CFM blower INSERT
can easily control Monsoon I without
(30" and 36" models) or 1,200-CFM
ever reaching over a dangerous cook-
blower (42" and 48" models).
INTERNAL BLOWER
INTERNAL BLOWER with ACT m
STANDARD
AIRFLOW CONTROL TECHNOLOGY'"
30"/36"Min. -May_ CFM
200 - 600
NA 200 - 390 200 - 290
30"/36"Min. -Max Sones
1-6
NA
1-4
1-3
42748" Min. -Max. CFM
450 - 1,200
350 - 590
350 - 390
NA
42"/48"Min. -May- Sones 3.5 - 9 3.3 - 6 3.3 - 4 NA
*AIRFLOW CONTROLTECHNOLOGYTM (ACTr")
is an exclusive feature built into specific Zephyr hoods which can
limit the maximum blower CFM to meet local code requiremerds.
V : Vill, 1W VW VW
0
.:.4i&i
7t
M
0
Includes Wireless Remote Control
?2
5r '?�8ry
sro .9i8-,
3/4 VIEW
(28") 14-1/4"
(34") 17-1/4"
(4011) 20-1/4"
(46") 23-1/4"
(28") 9-1/4"
to M
(34") 12-1/4"
M zo
�, (40") 15-1/4"
(46") 18-1/4"
co o
elec. T
k/o
M co
I � �
ID �
C/L
M �1'
N
TOP I
* Dimensions for 28" and 34" model sizes only
MODEL
Stainless Steel
AK9228BS
AK9234BS
AK924OBS
AK9246BS
Size
30" (28-3/8" x 19-1/4")
36" (34-3/8" x 19-1/4")
42" (40-3/8" x 19-1/4")
48" (46-3/8" x 19-1/4")
BLOWER PERFORMANCE
Blower CFM (Min. - Max.)
200 - 600
200 - 600
450 -1,200
450 -1,200
Sones (Min. - Max.)
1-6
1-6
3.5 - 9
3.5 - 9
ACT 590 CFM (Min. - Max)
NA
NA
350-590
350-590
ACT 590 Sones (Min. - Max.)
NA
NA
3.3 - 6
3.3 - 6
ACT 390 CFM (Min. - Max.)
200-390
200-390
350-390
350-390
ACT 390 Sones (Min. - Max)
1-4
1 - 4
3.3 - 4
3.3 - 4
ACT 290 CFM (Min. - Max)
200-290
200-290
NA
NA
ACT 290 Sones (Min. - Max.)
1-3
1-3
NA
NA
FEATURES
ACTrM Technology
Yes
Yes
Yes
Yes
Controls
Electronic Touch
Electronic Touch
Electronic Touch
Electronic Touch
Speed Levels
6*
6*
6*
6*
Auto Delay -Off
Yes
Yes
Yes
Yes
CleanAir Function
Yes
Yes
Yes
Yes
Lighting
LumiLight LED, 6W x2
LumiLight LED, 6W x2
LumiLight LED, 6W x2
LumiLight LED, 6W x4
Dual -Level Lighting
Yes
Yes
Yes
Yes
Filters
Pro Baffle x2
Pro Baffle x2
Pro Baffle x2
Pro Baffle x3
Grease Collection Tray
Yes
Yes
Yes
Yes
Wireless Remote Control
Yes
Yes
Yes
Yes
Recirculating Option
No
No
No
No
ADA Compliant
Yes
Yes
Yes
Yes
DUCT SPECIFICATIONS
Vertical Internal Blower
8" Round
8" Round
10" Round
10" Round
Horizontal Internal Blower
8" Round
8" Round
NA
NA
AC POWER
120V, 60Hz at Max. 5A
120V, 60Hz at Max. 5A
120V, 60Hz at Max. 7A
120V, 60Hz at Max. 7A
OPTIONAL ACCESSORIES
Make -Up Air Kit
MUA006A
MUA006A
MUA010A
MUA010A
MOUNTING HEIGHT RANGE**
26" - 36"
26" - 36"
26" - 36"
26" - 36"
WARRANTY
3 years parts, 1 year labor
3 years parts, 1 year labor
3 years parts, 1 year labor
3 years parts, 1 year labor
*When ACTT^' is enabled the maximum speed levels will change. 30" and 36" models: ACT 390 CFM = 3 speeds and ACT 290 CFM = 2 speeds. 42" and 48" models: ACT 590 CFM = 3 speeds and ACT
390 CFM = 2 speeds.
-Mounting height refers to distance between top of a 36" tall cooking surface and bottom of hood.
AIRFLOW CONTROL TECHNOLOGYr" (ACTT"')
is an exclusive feature built into specific Zephyr hoods which can
ACT'limit the maximum blower CFM to meet local code requirements.
Specifications subject to change, check zephyronline.com for up-to-date information.
Zephyr Ventilation 12277 Harbor Bay Parkway, Alameda, CA 945021 888.880.VENT
OCT20.0201
Window, Skylight and Door Schedule
Project Information
EDMONDS
Ref. U-factor
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
uescrlptlon KeT. U-Tactor
BATH WINDOW 0.30
LAUNDRY WINDOW 1030
Overhead Glazing (Skylights)
Component
Contact Information
TERRY WILLEY
Width Height
Qt. Feet Inch Feet Inch Area UA
Width Height
Qt. Feet Inch Feet Inch
1
2
6
3
6
1
2
6
3
6
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UA/Area
Description Ref. U-factor
Width Height
It. Feet Inch Feet Inch
Area UA
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
11
111
17.51 5.25
0.30
Area UA
11
111
11
111
11
111
11
111
11
111
11
111
2018 Washington State Energy Code-R 3 Sum of Overhead Glazing Area and UA 1 0.01 0.00
Overhead Glazing Area Weighted U = UA/Area 1 0.00
Total Sum of Fenestration Area and UA (for heating system sizing calculations) 1 17.5 5.25
I FASTENERS FOR PRESERVATIVE -TREATED AND I
■ FIRE -RETARDANT -TREATED WOOD SHALL BE OF
I HOT -DIPPED ZINC -COATED GALVANIZED STEEL, I
!STAINLESS STEEL, SILICON BRONZE OR COPPER. ■
(COATING WEIGHTS FOR ZINC -COATED FASTENERS
!SHALL BE IN ACCORDANCE WITH ASTM A153, IBC ■
SECTION 2304.10.5 & IRC SECTION 317.3
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ r
Z2 X 6 @16" O.C. W/2 X 6 PT SILL
R - 21 INSU U.O.N. IN WALL
EXISTING SFR NEW BATH AND LAUNDRY 2 X FLOOR JOIST AS PER PLAN
2 X RIM JOIST TYP.
3/4" T&G SUBFLOOR GLUED AND NAILED
nnnn
R-39 INS
ZMn1UZ=M
UUUU c4
EXISTING GARAGE SLAB 4
SOLID TREATED FRAMING GLUED AND NAILED
Z EXISTING SFR
CRAWLSPACE _
a° a
.a
EXISTING GARAGE
a ° a
FRAMING DETAIL @ GARAGE WALL SCALE 3/4" = 1'
RESUB
May 18 2022
r+@US CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
Z
~
O
N
LU (63
Z)U_
LU
1!1 Q
� Z
Ln 0
r Q
N LU
J) Z
Q
Q
Q Q
LU
Q
LU Z
LU LU
O
Q
O
LL
LU
LU
'Z
V
m LU
0 Q
w
0
> Q
0 LU
a �Q
(n _
z
Z C4
Q
lY
0
DATE:
5/18/2022
SCALE:
SHEET:
F-2
CO
5;