APPROVED REV1 STM ENG RESUB 1-Civil_Plan0 SET REBAR & CAP EMW LS #44651 O FOUND REBAR & CAP (AS SHOWN) ® FOUND CASED MONUMENT (AS SHOWN) ® FOUND BRASS DISK (AS SHOWN) �PMT� POWER METER P POWER POLE j POWER POLE W/LIGHT, TRANSFORMER & DROP SIGN STORM DRAIN MANHOLE /S, SEWER MANHOLE co SEWER CLEANOUT WATER METER WATER VALVE FRUIT TREE (R) DISTANCE PER REFERENCE (M) DISTANCE AS MEASURED (C) DISTANCE AS CALCULATED LS LICENSED LAND SURVEYOR F.F. FINISHED FLOOR HOGWIRE FENCE WOOD FENCE OH OH OH OH OVERHEAD UTILITY LINE --D----D----D----D--- STORM DRAIN LINE -S----S----S----S--- SEWER LINE --W----W----W----W--- APPROXIMATE WATER LINE HORIZONTAL DATUM NAD 1983(2011); PER RTK GPS TIES AND THE WASHINGTON STATE REFERENCE NETWORK (WSRN). UNITS OF MEASUREMENT ARE U.S. SURVEY FEET. VERTICAL DATUM NAVD 1988 PER RTK GPS TIES AND THE WASHINGTON STATE REFERENCE NETWORK (WSRN). UNITS OF MEASUREMENT ARE U.S. SURVEY FEET. LEGAL DESCRIPTION UTILITY CONTACTS STORM SEWER: EDMONDS PUBLIC WORKS (425) 771- 0235 SA NI TARP SEWER: EDMONDS PUBLIC WORKS (425) 771- 0235 WATER: EDMONDS PUBLIC WORKS (425) 771- 0235 ELECTRIC: SNOHOMISH COUNTY PUD PHONE: (425) 783-1000 GAS: SNOHOMISH COUNTY PUD PHONE. (425) 783-1000 TELEPHONE. CENTURY LINK FIRE DEPARTMENT SOUTH COUNTY FIRE (425) 551-1200 HAUL ROUTE NOTE: - WEST ON DALEY STREET TO 3RD AVENUE NORTH - SOUTH ON 3RD AVENUE NORTH TO MAIN STREET - WEST ON MAIN STREET TO SR 104 & MERGE ONTO SR 104 PARCEL A LOTS 31, 32 AND ALL THAT PORTION OF LOT 30 LYING ON THE WEST SIDE OF FOURTH STREET AS EXTENDED, ALL IN BLOCK 119, THE CITY OF EDMONDS, SNOHOMISH COUNTY, WA, ACCORDING TO PLAY THEREOF RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SAID COUNTY, SITUATE IN THE COUNT OF SNOHOMISH, STATE OF WASHINGTON. CONTAINING 7208 SQ. FEET PARCEL B LOTS 33 AND 34, ALL IN BLOCK 119, THE CITY OF EDMONDS, SNOHMOMISH COUNTY, WA, ACCORDING TO PLAT THEREOF RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SAID COUNTY, SITUATE IN THE COUNT OF SNOHOMISH, STATE OF WASHINGTON. CONTAINING 6600 SQ. FEET NOTES: 1. A SEPARATE DEMOLITION PERMIT IS REQUIRED FOR REMOVAL OF ANY EXISTING BUILDING. 2. THIS PERMIT DOES NOT AUTHORIZE GRADING ACTIVITY TO CROSS PROPERTY LINES OR AFFECT ADJACENT PROPERTIES UNLESS EXPLICITLY AUTHORIZED BY THE OWNER(S) OF THE PROPERTIES) AFFECTED. J. UNDERGROUND ALL NEW AND EXISTING ON -SIZE TRANSMISSION LINES FROM THE BUILDING TO THE POINT OF ORIGIN AT THE PRIMARY/DISTRIBUTION LINES FOR THE UTILITIES 4. ADJUST ANY EXISTING UTILITY WHICH MAY CONFLICT WITH STREET OR UTILITY IMPROVEMENTS REFERENCE SURVEYS R1) THE PLAT OF THE CITY OF EDMONDS, SNOHOMISH COUNTY, WA, RECORDED IN VOLUME 2 OF PLATS, PAGE 39 R2) RECORD OF SURVEY, RECORDING NO. 201112215004 R3) RECORD OF SURVEY, RECORDING NO. 9104255001 R4) RECORD OF SURVEY, RECORDING NO. 200708JO5220 R5) STATUTORY WARRANTY DEED, RECORDING NO. 200211200190 R6) SUPERIOR COURT DECREE NO. 10928 RECORDS OF SNOHOMISH COUNTY AUDITOR'S OFFICE CALL 3 WORKING DAYS BEFORE YOU DIG C 811 UTILITIES UNDERGROUND LOCATION CENTER (ID, MT, ND, OR, WA) jcul SAFETY PRECAUTION SHALL BE IMPLEMENTED BY ELECTRIC -RED SEWER - GREEN GAS/OIL - YELLOW CONTRACTOR(S)ATALL TRENCHING INACCORDANCE SURVEY -PINK TEL/CATV-ORANGE PROPOSED -WHITE WITH CURRENT OSHA STANDARDS WATER -BLUE P e 235.65'(C) 235.69'(R2) TACK uIN13/4" IRON PIPE SURVEYOR'S NOTES 1. THE PURPOSE OF THIS SURVEY IS TO DETERMINE THE LOCATION OF THE BOUNDARIES AND PROVIDE TOPOGRAPHIC INFORMATION OF THE PARCEL AS DESCRIBED HEREON. 2. THIS SURVEY WAS MADE BY FIELD TRAVERSE USING A LEICA 1203 3" ROBOTIC TOTAL STATION AND GS 14RTK GPS WITH RESULTING CLOSURES EXCEEDING THE MINIMUM ACCURACY STANDARDS AS SET FORTH BY WAC 332-130. 3. THE BOUNDARY CORNERS AND LINES DEPICTED ON THIS MAP REPRESENT DEED LINES ONLY. THEY DO NOT PURPORT TO SHOW OWNERSHIP LINES THAT MAY OTHERWISE BE DETERMINED BY A COURT OF LAW. 4. THE LEGAL DESCRIPTION IS PER RECORDS OF SNOHOMISH COUNTY AUDITOR'S OFFICE, RECORDING NO. 200802290945, DATED FEBRUARY 29, 2008. 5. FIELD WORK FOR THIS PROJECT WAS PERFORMED IN OCTOBER, 2020 AND IS THEREFORE A REFLECTION OF THE CONDITIONS AT THAT TIME. ALL MONUMENTS WERE VISITED OR SET IN OCTOBER, 2020. THIS SITE CONTAINS IMPROVEMENTS NOT LOCATED OR SHOWN AS A PART OF THIS SURVEY. 6. THIS SURVEY DOES NOT PURPORT TO SHOW EASEMENTS OF RECORD, IF ANY. 7. OVERHEAD UTILITY LINES SHOWN ON THIS MAP ARE INTENDED TO SHOW THE DIRECTION OF THE OVERHEAD UTILITY LINES ONLY AND DO NOT REPRESENT THE ACTUAL WIDTH, NUMBER OR LOCATION OF LINES(S) ON THE UTILITY POLES. NW 1/4 OF SW 1/4 SEC 24, TWP. 27N., RGE 03E., W.M. COVER SHEET PARKER EDMONDS DALEY EAST SFR - N88'45�21 "W c' ° 1 60. 00 '.'.'. '::... '.'. 66.34' 1 N88' ' 45 2 1"W I / 5' 'BSBL'.'.'.'.... 11 25.43' I ° FOUND REBAR & CAP "LSA 22969" / I k GARAG '� -� FFE=59.00' I I s, I 1 I I I LOT 31 LOT 30 ° • 1 LOT 32 I I I ° I I 1 25' LOT 35 v, I m Ih I I I m I m LOT A° 7,0801 SF . ai I m I vi I I I I ° . ,... ° Io I PROPOSED SF HOUSE SEE I LOT B UNDER O ARCHITECTURAL SEPARATE PERMIT I 0 PLANS I HOUSE I I MAIN FFE=66.00 I II DI BSMT FFE=56.57 LOT B I l 6,600 SFf d ' a VC 5' PRI VA TE DRAINAGE EASEMENT TO BENEFIT 20' BSBL _ LOT A d I _. ?5 I Q FOUND REBAR & CAP "LSA 22969" ------------ ------ If 10' SNO PUD d -----_-_- rn ° ?5 EASEMENT 60.00' G °' •p N88-45'21"W 120. 0' A. ,d d d S88'45'21"E 356.30'(R3)(R4) DALEY ST 4 4. d. S88.45'21"E -� FOUND CASED TACK IN 3/4" IRON PIPE WA D.O.E. SOIL AMENDMENT NOTES SOIL RETENTION. RETAIN, IN AN UNDISTURBED STATE, THE DUFF LAYER AND NATIVE TOPSOIL TO THE MAXIMUM EXTENT PRACTICABLE. IN ANY AREAS REQUIRING GRADING REMOVE AND STOCKPILE THE DUFF LAYER AND TOPSOIL ON SITE IN A DESIGNATED, CONTROLLED AREA, NOT ADJACENT TO PUBLIC RESOURCES AND CRITICAL AREAS, TO BE REAPPLIED TO OTHER PORTIONS OF THE SITE WHERE FEASIBLE. SOIL QUALITY. ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS SURFACE, INCORPORATED INTO A DRAINAGE FACILITY OR ENGINEERED AS STRUCTURAL FILL OR SLOPE SHALL, AT PROJECT COMPLETION, DEMONSTRATE THE FOLLOWING. 1. A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF 109 DRY WEIGHT IN PLANTING BEDS, AND 59 ORGANIC MATTER CONTENT IN TURF AREAS, AND A PH FROM 6.0 TO 8.0 OR MATCHING THE PH OF THE UNDISTURBED SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE CRITERIA. SUBSOILS BELOW THE TOPSOIL LAYER SHOULD BE SCARIFIED AT LEAST 4 INCHES WITH SOME INCORPORATION OF THE UPPER MATERIAL TO AVOID STRATIFIED LAYERS, WHERE FEASIBLE. 2. MULCH PLANTING BEDS WITH 2 INCHES OF ORGANIC MATERIAL 3. USE COMPOST AND OTHER MATERIALS THAT MEET THESE ORGANIC CONTENT REQUIREMENTS. A. THE COMPOST MUST ALSO HAVE AN ORGANIC MATTER CONTENT OF 407. TO 6590, AND A CARBON TO NITROGEN RATIO BELOW 25: 1. THE CARBON TO NITROGEN RATIO MAY BE AS HIGH AS 35: 1 FOR PLANTINGS COMPOSED ENTIRELY OF PLANTS NATIVE TO THE PUGET SOUND LOWLANDS REGION. B. CALCULATED AMENDMENT RATES MAY BE MET THROUGH USE OF COMPOSTED MATERIALS MEETING (A.) ABOVE, OR OTHER ORGANIC MATERIALS AMENDED TO MEET THE CARBON TO NITROGEN RATIO REQUIREMENTS, AND MEETING THE CONTAMINANT STANDARDS OF GRADE A COMPOST REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT •.I.1.1.�.1.1.1.1.1.1 .1. 1.1 .1. 1.1 .1. 1.1.1.1.1.1� 6" CONIC PIPE DIRECTION PER CITY OF EDMONDS GIS GRAPHIC SCALE 20 0 10 20 SCALE: 1 - 20 25' w 5.00' S88.45'21"E 329.35'(C) 329.32'(R1)(R2) FOUND 3" BRASS DISK ON SURFACE CONSTRUCTION SEO UENCE NOTES 1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT 425-771-0220, EXT. 1326. TWO DAY (48 HR) NOTICE IS REQUIRED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. J. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATIONOUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS CITY ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED. 6. DEMOLISH EXISTING STRUCTURES 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 8. CLEAR, GRUB & ROUGH GRADE SITE. REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW) 9. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 13, STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SITE. 14. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. REFER TO CIVIL PLANS APPROVED 6/25/2021 FOR COMPLETE ENGINEERING REQUIREMENTS COMPLIES WITH APPLICABLE CITY STORMWATER CODE RE ONLY RESUB Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVISION Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 1. COVER SHEET 2. T.E.S.C. PLAN 3. SITE IMPROVEMENT PLAN 4. CONSTRUCTION DETAILS - 1 5. CONSTRUCTION DETAILS - 2 { { { { -7- 1 M 1 14 1 VICINITY MAP NOT TO SCALE PROJECT DATA PROPERTY ADDRESS. 327 DALEY ST, EDMONDS, WA TAX LOT NUMBER: 00434211903000 SI TE AREA: 7,080 SF (0.16 AC.) ZONING DESIGNATION: R-6 PROJECT CONTACTS OWNER/ DALEY STREET BUILDERS, LLC APPLICANT 323 DALEY STREET EDMONDS, WA 98020 PHONE. (425) 359-9789 CONTACT DENNIS PARKER ARCHITECT. CLOWARD SUSTAINABLE DESIGN 630 NW 81ST ST SEA TTLE, WA. 98117 PHONE: (206) 755-0759 CONTACT BRIAN CLOWARD Cl VIL ENGINEER: LI TCHFIELD ENGINEERING 12840 81 ST AVE NE KIRKLAND, WA 98034 PHONE. (425) 821- 5038 CONTACT KEI TH LI TCHFIELD, PE SURVEYOR: INFORMED LAND SURVEY PO BOX 5137 TACOMA, WA 98415 PHONE. (253) 627-0137 CONTACT EVAN WAHLSTROM GEOTECHNICAL THE RILEY GROUP ENGINEER: 17522 BOTHELL WAY NE BOTHELL, WA 98011 PHIONE: (425) 415-0551 CONTACT DAVID BAUMGARTEN, LHG R-1 1. THESE PLANS ARE APPROVED FOR STANDARD ROAD AND DRAINAGE IMPROVEMENTS ONLY. PLANS FOR STRUCTURES SUCH AS RETAINING WALLS REQUIRE A SEPARATE REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. 2. SPECIAL INSPECTIONS FOR STRUCTURAL ASPECTS OF OF THE PROJECT MAY BE REQUIRED DURING VARIOUS STAGES OF THE PROECT. CONTRACTOR TO BE RESPONSIBLE FOR COORDINATION AND OBTAINING INSPECTIONS WHEN AND WHERE NECESSARY. J. SEE ARCHITECTURAL PLANS FOR BUILDING SECTIONS AND ALL LOCATIONAL/DIMENSIONAL ASPECTS OF BUILDINGS. 4. SEE ARCHITECTURAL AND STRUCTURAL PLANS FOR ALL BUILDING AND RETAINING WALL DETAILS. 5. COORDINATE ALL SITE CIVIL CONSTRUCTION WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL/PLUMBING AND LANDSCAPE PLANS SITE IMPR 0 VEMENT NOTES 1. PROOF OF LIABILITY INSURANCE SHALL BE SUBMITTED TO THE CITY PRIOR TO THE PRE -CONSTRUCTION MEETING. 2. RETAINING WALLS GREATER THAN FOUR (4) FEET IN HEIGHT REQUIRE A SEPARATE BUILDING PERMIT. 3. FILL MATERIAL PLACED UNDER BUILDING FOUNDATIONS OR PAVEMENT SHALL BE CRUSHED BASE ROCK OR COMPACTED STRUCTURAL FILL IN ACCORDANCE WITH CITY AND WSDOT STANDARD SPECIFICATIONS. 4. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES, NOT LOCATED WITHIN A TRAVELED ROADWAY OR SIDEWALK, SHALL HAVE SOLID LOCKING LIDS. 5. THIS PLAN DOES NOT SHOW THE LOCATION OF ALL EXISTING UTILITIES, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES PRIOR TO EXCAVATION. 6. THE CONTRACTOR SHALL EXPOSE ALL EXISTING PIPING THAT WILL BE CONNECTED TO WITH NEW PIPING. DEPTH, LOCATION, AND CONDITION SHALL BE RELAYED TO THE ENGINEER IF CONDITIONS VARY SIGNIFICANTLY FROM WHAT IS DETAILED OR ANTICIPATED. 7. ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE TO DETAILS AND SPECIFICATIONS OF CITY STANDARDS. ALL CONSTRUCTION DEBRIS GENERATED DURING CONSTRUCTION TO BE REMOVED & DISPOSED OF AT AN APPROVED LOCATION OFF SI TE. 8. ALL CUT MATERIAL GENERATED DURING THE PROJECT THAT IS NOT ACCEPTABLE FOR USE AS COMPACTED FILL MATERIAL AT ANOTHER LOCATION ON -SITE MUST BE HAULED TO AN APPROVED LOCATION OFF -SITE. APPROVED FOR CONSTRUCTION ONDS STORMWATER ENGINEERING DIVISION BY. REVISION ONLY APPROVED AS NOTED CITY l m_wA 1 /23/2021 _ � N � �� JOB No. :�►»nrrr•�►��y�:i�I���rcl�y���1►��yi�ll��rlr�1]]:i�l%��1:��rl��rJle�lrl��:i�]lrxK�]a� .1� TH IN DE FALL WIDTH DRESS/EGRESS DETAIL NOTES: 1D THE MINIMUM LENGTH SHALL BE EXTENOE)O AS NECESSARY TD ENSURE MATERIAL IS N07 TRACKED OFF SITE AND/01R INTO THE P013I1C RIGHT-OF-WAY, ATR DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN, SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE, IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH S.1 SLOPES WILL BE PERMITTED, 2, MAINTENANCE - THE ENTF"OE SHALL SE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRA,CKINO OR FLOWING OF SEDIMENT OFF" SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSIN Q WrrH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR OLEANpIlT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AMD/OR 090 PUBLIC RIGi�T-OF-WAY MUST BE REMOVED IMMEDIATELY. 1 WHEELS SHALL BE CLEANED TO-REMi}1/E SEDIMENT PRIOR TO LEAVING THE SITE, WHEN WASHING IS USED, 1T SHALL ISE DONE ON AN AREA STABILIZED WITH QUARRY SPALLa AND WHICH ID -RAINS INTO Add APPROVED SEDIMENT TRAPPING I]EVIT:E. 4, INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. PROJECT SIZE MIN LENGTH OF �fEET) QUARRY' $PALLS* < 1 4 ACRE 130 < 1 ACRE i5O i 3 ACRE 100 > 3 ACRE 100 PROVIDE ATp OR ASPHALT if�ANSITION WHERE fRONTAOE ROAD IS AN ARTERIAL, LENGTH TO .BE DETERMINED BY CITY INSPECTOR, MY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER 'CORK CM BEGIN REVISION DATE STABILIZED CONSTRUCTION JAxUARY 2.01E ,aCITY OF EDMONDS ENTRANCE � r'y. PUBLIC WORKS STANDARD DEPARTMENT DETAIL ''T 3��� APPROVED BY R. I:NOLISH ER-901 E 20 x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 (;A WIRE FABRIC EQUAL NATIVE BACKFILL MATERIAL FILTER FABRIC MATERIAL IN CONTIUOUS ROLLS USE STAPLES OR WIFE RINGS TO ATTACH FA R I C TO WIFE 2" ;x 2" WOOO/STEEL POETS-\ I YhORE MESH (FENCE TO SUPPORT FILTER fiABRIC BURY 3070M OF FILTER MATSIIAL S" TO 12" 6' MAX NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT, 2, SILT FENCE TO BE PLACED DOWNSLOPE OF CONMUCTION ACTIVITY CITY OF EDMONDS PUBLIC WGR�<S DEPARTMENT CITY INSPECTION REQUIRED ON ,ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN REVISION DATE FILTER FABRIC FENCE JAxUARY 2-018 FILTRATION( SYSTEMS STANDARD DETAIL APPROVED BY: R. B12LISH E R - 9 00 GRAPHIC SCALE 20 0 10 20 SCALE: 1" = 20' CALL 3 WORKING DAYS BEFORE YOU DIG ff _T 811 UTILITIES UNDERGROUND LOCATION CENTER (ID, MT, ND, OR, WA) SAFETY PRECAUTION SHALL BE IMPLEMENTED BY ELECTRIC - RED SEWER -GREEN GAS/OIL - YELLOW .^.ONTRACTOR(S)ATALL TRENCHING IN ACCORDANCE SURVEY -PINK TEUCAN-ORANGE PROPOSED - WHITE WITH CURRENT OSHA STANDARDS WATER -BLUE a 3� CITY OF EDMONDS PUBLIC WGR�<S DEPARTMENT CATCH SAS I N J a CONSTRUCTION . "a ENTRANCE PER COE a STD PLAN CE-ER-901 EDGE OF GRAVEL EDGE OF GRAVEL / WOOD FENCE 126.34' 60.00' ON LIN EXISTING GARAGE FOUND REBAR & CAP YSA 22969" 6 LOT 35 � I / <�<�< / Ov I� NOTE. • ALL DISTURBED PERVIOUS AREAS TO BE COMPOST AMENDED PER v I A 2014 SWMMWW BMP T5.13. F.F. EL=60.92' NOTE. • INSTALL AND RESIIDENCE I ' MAINTAIN ALL 7ESC MEASURES IN ACCORDANCE TO APPROVED PLANS, Cl TY 4 OF EDMONDS, STANDARD DETAILS, AND ALL OTHER N0°D MEASURES THAT MAYBE PORCH REQUIRED DURING CONS7RUC77ON. d jz 'OUND REBAR & SAPt2969' dp `Z ITEWALKWAY d ENCE .3' W BO.00::::iJ -� p 52.0' iALLEY FENCING PER STD CE-ER-900-2 °o°o°e°e°e°000e --- _L_ LOT 31 \ / TEMP. ri�r30 I STOCKPII_F AREA! t £OVER WITHIN J / \ 24 HOURS _ate 777, Q I LOT 32 14• 4 I TREE TO BE REMOVED I I I a _I F y ALL STRUCTURES, CONCRETE, BRICKS, J RETAINING WALLS AND d INTERNAL FENCING TO BE $ REMOVED. ! t tl 1� I d 0 I A O'S' CLEARING AND .d p d GRADING LIMI TSB` Dry/ \ n N WESTERLY MARGIN � � / 25' EXTENDED / � � p'a d p. •p '•O N88'45'21"W 120. ' d• ,d d CONIC. SIDEWALK d 'e p; .d• I d p' .I a d p• dd n. : d CONC. CURB J ----D----D-- -D- 7/--D----D----D---- -IN- - - - W - - - -W � - -W- APPROXIMATE,WATER LINE PER Or pF EDMONDS US VV----VV----W -- W----W----W-� rg �ry M I i - S -1 �_- - � - - - - - - 188.45.21 S88'45'21 "E 356.30'(R3)(R4) \ DALEY ST BE 5 C TY OF 128 SF �i- ZS• LOT 30 A TED TO 1 I I I I I - PRO-TECT ARI: A OF INFIL TRENCH WUCi ,T 4' HI A CONSTRTS( IOR NO E ORK EXC VATS 1-' R 7REN'H I � I I 0 41 6Z I OH- OHO =c ®r ye--lAa---W�---W -- m 6" CONC PIPE / DIRECTION PER CITY OF EDMONDS CIS -i S88'45'21"E 329.35'(C) 329.32'(R1)(R2) NOTE. • FILTER SOCKS PER COE ER-902 SHALL BE ADDED TO DOWNSTREAM CATCH / BASINS IN THE VICINITY OF ,^.ONSTRUC770N. CONIC- - C CURB -` rnur rno- FILTEIR SOCK WITH OVM FLOW HOLES {rnP) NOTES: 1. CONTRACTOR/(DEVELOPER SHALL MAINTAIN THIS APPUCA71ON AT ALL TIMES DURING 0ONSTRUCT1ON PERIOD. 2, ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL 3, CITY INSPECTION REQUIRES ON ALL EROSION CONTROL METHODS3EFORE OTHER WORK CAN BEGIN, TEMPORARY SEDIMENT TRAP FOR CATCH BASINS AP'P°ROVEID BY; IR, KNOLISH REVISION DATE JANUARY 2018 STANDARD DETAIL ER-902 - - W- EROSION & SEDIMENT CONTROL NOTES FENCIN( AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL AS- BUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER NGE SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION D AND SHALL CONTACT THE UNDERGROUND UTILITIES Revised 05.15.2017 LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13 SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTI VE ACTI VI TIES (i.e. HEAVY EQUIPMENT, STOCKPILING). 14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWA TER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. _ 18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT TO THE DRAINAGE SYSTEM DOWNSTREAM OF THE SITE STORMWATER MANAGEMENT FACILITY. 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 21 A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC 1. PRIOR TO BEGINNING EARTH DISTURBING ACTIVITIES, INCLUDING CLEARING AND GRADING, ALL CLEARING LIMITS, EASEMENTS, SETBACKS, TREES AND DRAINAGE COURSES SHALL BE CLEARLY DEFINED AND MARKED IN THE FIELD TO PREVENT DAMAGE AND WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, PROVIDE TO THE OFFSITE IMPACTS. CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO 2. CONSTRUCTION VEHICLE ACCESS AND EXIT SHALL BE LIMITED TO ONE ROUTE IF POSSIBLE. ACCESS POINTS SHALL BE STABILIZED JEFF.KOBLYK@EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE COMPLETED BY THE WITH QUARRY SPALLS OR CRUSHED ROCK TO MINIMIZE THE TRACKING OF SEDIMENTS ONTO PUBLIC STREETS. WHEEL WASH OR TIRE BATHS SHALL BE LOCATED ON -SITE. IF SEDIMENT IS TRANSPORTED ONTO A ROAD SURFACE, THE PAVEMENT SHALL BE OWNER ANNUALLY THEREAFTER. CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED FROM THE PAVEMENT BY SHOVELING OR 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE SWEEPING AND BE TRANSPORTED TO A CONTROLLED SEDIMENT DISPOSAL AREA. STREET WASHING WILL ONLY BE ALLOWED AFTER RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN SEDIMENT IS REMOVED IN THIS MANNER. PAVEMENT WASHING SHALL NOT OCCUR UNTIL ALL STORM DRAIN INLETS, LOCATED DOWNSTREAM OF THE WASHING AREA, HAVE BEEN PROTECTED BY PLACEMENT OF A FILTER CLOTH UNDER THE INLET GRATE. ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR J. PROPERTIES AND WATERWAYS DOWNSTREAM FROM THE DEVELOPMENT SITE SHALL BE PROTECTED FROM EROSION DUE TO STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ON- SITE INCREASES IN THE VOLUME, VELOCITY, AND PEAK FLOW RATE OF STORMWATER RUNOFF FROM THE PROJECT SITE. EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS 4. PRIOR TO LEAVING THE SITE, STORMWATER RUNOFF SHALL PASS THROUGH APPROVED SEDIMENT BARRIERS OR FILTERS, DIKES, FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. OR ANY OTHER APPROVED FACILITY INTENDED TO TRAP SEDIMENT. THESE SEDIMENT CONTROLLING MEASURES SHALL BE 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY CONSTRUCTED AS THE FIRST STEP IN GRADING. THESE FACILITIES SHALL BE FUNCTIONAL BEFORE ANY OTHER LAND DISTURBING ACTIVITY TAKES PLACE. EARTHEN STRUCTURES SUCH AS DAMS, DIKES, AND DIVERSIONS SHALL BE SEEDED AND MULCHED SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR ACCORDING TO THE TIMING INDICATED UNDER ITEM 5. APPROVAL. 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND 5. ALL EXPOSED AND UNWORKED SOILS SHALL BE STABILIZED BY THE PLACEMENT OF SOD OR OTHER VEGETATION, PLASTIC COVERING, MULCHING, APPLICATION OF BASE ROCK WITHIN AREAS TO BE PAVED, OR SOME OTHER APPROVED MEANS, TO IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. PROTECT THE SOIL FROM THE EROSIVE FORCES OF RAINDROP IMPACT AND FLOWING WATER. FROM OCTOBER 1 THROUGH APRIL 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS 30, NO SOILS SHALL REMAIN EXPOSED AND UNWORKED FOR MORE THAN 2 DAYS. FROM MAY 1 THROUGH SEPTEMBER 30, NO OR SPOT ELEVATIONS SHOWN. SOIL SHALL REMAIN EXPOSED AND UNWORKED FOR MORE THAN 7 DAYS. THIS CONDITION APPLIES TO ALL SOILS ON SITE, 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 59 WHETHER AT FINAL GRADE OR NOT. THE SOIL STABILIZATION MEASURES SELECTED SHOULD BE APPROPRIATE FOR THE TIME OF YEAR, SITE CONDITIONS, ESTIMATED DURATION OF USE, AND THE POTENTIAL WATER QUALITY IMPACTS THAT THE STABILIZATION SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. MEASURES MAY HAVE ON THE DOWNSTREAM WATERS. SOIL STOCKPILES SHALL BE STABILIZED AND PROTECTED WITH SEDIMENT 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN TRAPPING MEASURES. SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, 6. CUT AND FILL SLOPES SHALL BE DESIGNED AND CONSTRUCTED IN A MANNER THAT WILL MINIMIZE EROSION. CONSIDER SOIL TYPE STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND ITS POTENTIAL FOR EROSION. REDUCE SLOPE RUNOFF VELOCITIES BY (1) REDUCING THE LENGTH OF CONTINUOUS SLOPES BY AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. USING TERRACING AND DIVERSIONS, (2) REDUCING THE GRADE OF THE SLOPE, AND (3) ROUGHEN SLOPE SURFACE. CONTAIN CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, DOWNSLOPE COLLECTED WATER IN PIPES OR PROTECTED CHANNELS. AS REQUIRED. 7. ALL STORM DRAIN INLETS MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT STORMWATER RUNOFF SHALL 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY NOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR TREATED To REMOVE SEDIMENTS. PROCEDURES FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, STREET 8. ALL TEMPORARY ON -SITE CONVEYANCE CHANNELS SHALL BE DESIGNED, CONSTRUCTED AND STABILIZED To PREVENT EROSION. CLOSURES OR OTHER ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT RELOCATE OR STABILIZATION, INCLUDING ARMORING MATERIAL, ADEQUATE TO PREVENT EROSION AT ALL DISCHARGE POINTS, ADJACENT STREAM ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE BANKS, SLOPES AND DOWNSTREAM REACHES, SHALL BE PROVIDED. FIRE MARSHAL. 9. ALL POLLUTANTS, INCLUDING WASTE MATERIALS AND DEMOLITION DEBRIS, THAT OCCUR ON -SITE DURING CONSTRUCTION SHALL 30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS BE HANDLED AND DISPOSED OF IN A MANNER THAT DOES NOT CAUSE CONTAMINATION OF STORMWATER. MAINTENANCE AND AND/OR SERVICE INTERRUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE REPAIR OF HEAVY EQUIPMENT AND VEHICLES INVOLVING OIL CHANGES, HYDRAULIC SYSTEM DRAIN DOWN, SOLVENT AND UTILITY COMPANIES CONNECTIONS TO DE -GREASING CLEANING OPERATIONS AND OTHER ACTIVITIES WHICH MAY RESULT IN DISCHARGE OR SPILLAGE OF POLLUTANTS TO Revised 05.15.2017 THE GROUND OR INTO STORMWATER RUNOFF, MUST BE CONDUCTED UNDER COVER AND ON IMPERVIOUS SURFACES. THESE SURFACES SHALL BE CLEANED IMMEDIATELY FOLLOWING ANY DISCHARGE OR SPILLAGE INCIDENT. WHEEL WASH, OR TIRE BATH WASTEWATER, SHALL NOT BE DISCHARGED TO THE STORM DRAIN, OR ON -SITE STORMWATER TREATMENT SYSTEM. EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE 10. ALL TEMPORARY AND PERMANENT EROSION AND SEDIMENT CONTROL FACILITIES SHALL BE MAINTAINED AND REPAIRED AS NEEDED AUTHORITIES GOVERNING SAID UTILITIES. TO ASSURE CONTINUED PERFORMANCE OF THEIR INTENDED FUNCTION. 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 32. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE AND INSPECTED AND GRADING NOTES ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE PRIOR TO 1. ALL CUT MATERIAL GENERATED DURING THE PROJECT THAT IS NOT ACCEPTABLE FOR USE AS COMPACTED FILL MATERIAL AT BACKFILLING. ANOTHER LOCATION ON -SITE MUST BE HAULED To AN APPROVED LOCATION OFF -SITE. 33. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO 2. ALL TEMPORARY OR PERMANENT SLOPES SHALL NOT EXCEED 2H: 1V UNLESS APPROVED BY A GEOTECHNICAL ENGINEER. DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY, J. FILL MATERIAL PLACED UNDER BUILDING FOUNDATIONS OR PAVEMENT SHALL BE CRUSHED BASE ROCK OR COMPACTED 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE. STRUCTURAL FILL IN ACCORDANCE TO WSDOT STANDARD SPECIFICATIONS. 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL 4. ROCKERY AND/OR RETAINING WALLS GREATER THAN FOUR (4) FEET IN HEIGHT REQUIRES A BUILDING PERMIT. BE COMPACTED TO 95% COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 5. IT WILL BE THE PERMITEE'S RESPONSIBILITY TO SUCCESSFULLY CAP AND ABANDON ALL EXISTING UTILITIES WITHIN THE 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE DEVELOPMENT IN ACCORDANCE TO THE GOVERNING UTILITY AGENCY. RESUB POLYETHYLENE PLASTIC FOAM AS A CUSHION BETWEEN THE UTILITIES. 37, SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE GENERAL NOTES Nov 05 2021 UTILITIES WITHIN THE BUILDING. CITY OF O 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS DEVELOPMENT C ERVES DEPARTMENT 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM. STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS.- - CURRENT INTERNATIONAL BUILDING CODE (IBC) - 2020 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION - WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN (CURRENT EDITION) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE J. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION. REVISION Nov 052021 APPROVED FOR CONSTRUCTION EDMONDSCITY OF DEVELOPMENT SERVICES M 0 N DS DEPARTMENT STORMWATER ENGINEERING DIVISION r-� REVISION ONLY APPROVED AS NOTED C/ ,- �,II l / LI_rMWA112312021 PAP N N LJ 0 N N M 11-1 W N 7- c)c W CY) �� zC7� Lclf W � �_ --c ) C) c� dT oc N 7 1 � 111- Z QJ_j uj 0 Z Q z ww000000 aJ Z oQ�Mr- uj1 m�< ' U Q u„I W Ln J c >�0ZLo � r� � , N a Ld LE � O c o W �_ I= Lu SHEET 2 of 5 JOB No. EXTEND LINER AS NEEDED TO SECURE DURING CHECK DAM SPACING 11' CONSTRUCTION DESIGN WATER 3" CHECK DAM CLEARANCE SURFACE ELEVATION SLOE 12" (MIN) COVER PERMEABLE PAVEMENT SECTION, SEE NOTE 2 c 3" (MIN) KEY v 30 MIL LINER 1 (TYP), SEE NOTE 4 CHECK DAM 12" (MIN) HEIGHT =5" SLOTTED PVC UNDERDRAIN PIPE IMPERMEABLE LINER CHECK DAM WITH SUBSURFACE 6" (MIN) BEDDING CONTROL STRUCTURE PER STD DETAIL NOTES: SD-628, SEE NOTE 3 1. DESIGNER SHALL DETERMINE AND SPECIFY SUBSURFACE CHECK DAM SPACING BASED ON THE SUBGRADE SLOPE AND DESIGN AVERAGE STORAGE DEPTH REQUIRED. TYPICAL MAXIMUM SPACING CAN BE ESTIMATED BY DIVIDING THE CHECK DAM HEIGHT BY -HE SUBSURFACE SLOPE. 2. SEE STD DETAIL SD-621 THROUGH SD-624 FOR PERMEABLE PAVEMENT SECTION. 3. IF REQUIRED, UNDERDRAIN PIPE SHALL BE 6" MINIMUM DIAMETER (PRIVATE), 8" MINIMUM DIAMETER (PUBLIC). SLOPE PIPE AT 0.5% MIN UNLESS OTHERWISE SPECIFIED. PROVIDE ONE CLEANOUT (MIN) PER 100 FEET OF UNDERDRAIN, AND AT EACH END. LOCATE UNDERDRAIN BELOW STRUCTURAL PAVEMENT BASE DEPTH. 4. LINER SHALL BE HDPE CONFORMING TO GEOSYNTHETIC RESEARCH INSTITUTE (GRI) GM13 OR LLDPE CONFORMING TO GRI GM17. REVISION DATE `ICITY OF EDMONDS PERMEABLE PAVEMENT DECEMBER 2017 -= SUBSURFACE PUBLIC WORKS CHECK DAMS STANDARD DEPARTMENT DETAIL Fs i y$cJ APPROVED BY: R. ENGLISH S D - 627 (Ml'N) PAVEMENT BASE COURSE, BEE NOTE 2 PATS, 2" (MIN) 5" OR CSCC, 3" (MIN) (MIN) OR PER MANUFACTURER RECOMMENDATION 6" (MIN) V (MIN) ABOVE SEASONAL HIGH GROUNDWATER TABLE OR HYDRAULICALLY RESTRICTIVE LAYER POROUS HMA/WMA, SEE NOTE 1 PERMEABLE ASPHALT TREATED BASE COURSE OR CRUSHED SURFACING CHOKER COURSE, SEE NOTE 3 PERMEABLE BALLAST, SEE NOTE 4 RUNOFF TREATMENT LAYER (IF REQUIRED PER EDMONDS STORMWATER CODE), SEE NOTE 5 GRADE, SEE NOTE 6 GENERAL NOTES: 1. REfER TO THE 2017 CITY OF EDMONDS STORMWATER ADDENDUM FAR SETBACK (CHECKLIST 11) AND INFEASIBILITY REQUIREMENTS. 21 THE MINIMUM THICKNESS SHOWN ABOVE MAY NOT BE SUFFICIENT FAR ALL APPLICATIONS, A PROJECT SPECIFIC PAVEMENT DESIGN SHALL BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON IN CIVIL ENGINEERING TO., 2,1, SUPPORT THE ANTICIPATED LOADING (EG, PAVEMENT DESIGN LIFE, INITIAL AND TERMINAL SERVICEABILITY, RELIABILITY, ETC,) AND 2,2. TO SATISFY THE HYDROLOGIC REQUIREMENTS OF THE CITY OF EDMONDS STORMWATER CODE (LE„ CODE MAY WARRANT A THICKER PAVEMENT SECTION THAN THE MINIMUM STRUCTURAL SECTION REQUIRED), 3. FOR SUBGRADE SLOPES 3% OR GREATER, SUBSURFACE CHECK DAMS OR OTHER METHODS TO PROMOTE SUBSURFACE PQNDING ARE REQUIRED, 4, GEOTEXTILE SHALL NOT BE USED IN PAVEMENT SECTION UNLESS REQUIRED BY GEOTECHNICAL ENGINEER, IF REQUIRED, GEOTEXTILE SHALL CONFORM TO W'SDOT 9.33.2(1) GEOTEXTILE FOR SEPARATION, WOVEN TYPE. S. REFER TO WS-DOT LOCAL AGENCY 0SP9 DIVISIONS 2-�9 FOR APWA GSPs. NOTES, 1. POROUS HMA SHALL CONFORM TO REQUIREMENTS OF APWA GSP 5-04. SURFACE SLOPE SHALL BE BETWEEN 0Z% AND SX. 2. PAVEMENT BASE SHALL BE INSTALLED PER APWA GSP '4-04.3(5) SHAPING AND COMPACTION. 3. PERMEABLE ASPHALT TREATED BASE (PATS) SHALL CONFORM TO THE REQUI-REMENTS OF APWA GSP 4-SA2. CRUSHED SURFACING CHOKER COURSE (CSOC) SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-0-4.2(9-03,9(2)),OPT2, 4. PERMEABLE BALLAST $HALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-C4.2(9-ID3.9(2)),OPT1. 5. RUNOFF TREATMENT LAYER SHALL MEET THE REQUIREMENTS OF 2017 CITY OF EDMONDS STDRMWATER ADDENDUM, 61 PREPARE AND PROTECT SUBGRADE PER APWA GSP 2-06.3(3) SUBGRADE FOR PERMEABLE PAVEMENTS. -REASION DATE CITY OF EDMONDS TYPICAL POROUS APRIL 2021 F A ASPHALT PAVEMENT � m PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED) BY: R. ENGLISH SD-621 TYPE OF AREA SQUARE FOOTAGE STORMWATER FACILITY LAWN AND LANDSCAPE 3694 SOIL AMENDMENT ROOFS 2711 INFILTRATION TRENCH HARD SURFACES 675 PERMEABLE PAVEMENT OFFSITE ALLEY 1003 PERMEABLE PAVEMENT OFFSITE APPROACH 385 NONE GRAPHIC SCALE NOTE. IF RIM TO INVERT 20 0 10 20 ELEVATION OF ANY STORM STRUC7URE EXCEEDS 5' THEN A TYPE 2 MANHOLE SCALE: 1" = 20' WILL BE REQUIRED. NOTE. • EXISTING FAILING, DAMAGED, OR NON-ADA COMPLIANT FRONTAGE IMPROVEMENTS SHALL BE REMOVED AND REPLACED AS DETERMINED BY THE CITY ENGINEERING INSPECTOR. IF ANY PORTION OF THE SIDEWALK ON DALEY STREET OR 4TH AVE IS RECONSTRUCTED, STREET TREES SHALL BE REQUIRED. FOUND REBAR d& CAP "LSA 22969" LOT35 N N NOTE ALL FINAL RESTORATION COMMUNICATION UTILITIES• PERMEABLE PAVEMENT TO \ WITHIN THE RIGHT-OF-WAY TV, TELEPHONE, CABLE, MATCH EXISTING GRADE SHALL BE COMPLETED BY THE J ETC. (SPECIFIC LOCATION \ \ CONTRACTOR, NOT THE CITY TO BE DETERMINED BY OF EDMONDS. UTILITY PURVEYOR) 5 43 E TO BE EXTENDED 1 UP DR I V EW Y APP ROACH 0 AC ' h TY PE ALL E1 ALLEY FR OM OM 3R ' D AV ENUE EN OR .ERME,4BLE:�:P'��:...�::,; �:::�:� ��� �������������.��.. �� : ��:" `'``;' �."' . .... . ° PER CO DETAIL TR-541 PER DISCUSS/ONE WITH SNO PUD. / :ALLEY FER:: COE DETAIL :� ... '.......'.. / C9 s I 0 GAS '. GAS GAS.:'. .c.'.... :..W...''::'.�...'...'.. . A, 1 N88'45'21 126.34' 60.00' ...... .. IN88'45'21 PERMEABLE 66.34' 25.43' I I PAVEMENT 5 BSBL °S EMERGENCY BACK P 24" PUM BASIN PER DRI VEWAY ADU PARKING .: �..o. I:: ; GARAGE I I GENERATOR s. DETAIL IS SHEET (FQ"071NG DRAINS ONLY) ELEC7RIC BOX FOR .... I::I: FFE=59.00' o I LOT31 Lul.;u 25' I POWER SERVICE :: `:.. ':..:: LOT 32 1 25' REPLACE EXISTING D VEWAY PVC PE F PIPE m I I LOT A APPRO CH WITH CUR i AND I I m 0017NG DI�4IN ® I I N I m 7, OSOi SF s I GUTTER PER COE DET,,IIL =55.05 v o = TR-520 AND SIDEWA ' PER I *NOTE- A 6" PVC BACKWATER VALVE I 4" R00 DRAIN 77GH7Ll I CAP COE DETAIL TR-531 LJ �.. / REQ'D BETWEEN J, I `I (TYP). LL ROGF DRAIN SDCO ITHE ONSITE I J ': TO DE N110N TANK. \ FiD RC I N E: I P I PRIVATE CB & 18 90 Y -MOL PI E PUBLIC DRAIN. I... PROPOSED SF HOUSE I �2 QP LOT B UNDER I SEE ARCHITECTURAL I I r � I a \ I SEPARATE PERMIT I HOUSE PLANS I i 4' PVC 1.09 (R00 �J MAIN FFE=66.00 D AIN��LLECTOR S STEM) I REFER TO CIVIL PLANS CB-J TYPE -[ / BSMT FFE=56.57 � I 1E=57. APPROVED 6/25/2021 FOR STRUCT. PER COE STD SD-300 l... I & 3D1 y' 7EE W/"4 x "18 11 11 vI $I COMPLETE ENGINEERING RIM=59.50t lE () J. I VE 178 LF - 1SEH-89 REDUCER (NOTE' 8" W =56,OD , AN ADD177ONAL ¢I REQUIREMENTS -PPRESSURE PUMP LINE a REDUCER MAY ME LOT B IE (i" W)=56.00 WITRACER TAPE 6" ABOVE NECESSARY FOR 6,600 SFt OVERFLOW=57.50 7HE 4' x 18" / INSTALL PVC FLOW RESTRICTOR 77?ANS1710N) 93 LF - 1 " N12 CPE TEE W/0.50" ORIFICE S0 I I( I FG = 60.0 - 60.50 CB-2 TYPE 1 PER COE El IE=54. t : "I J \ TOP OF Pl E = 57.50 / STD SD-303 W SOLID LID p _- ' IE = 56. 0 RIM=57.5t MATCH FG - r SDCO , - - - - / IE 1.5" (E)=56.00 (LOT A FOOTING) 5' PRI VA TE DRAINAGE II - � IE 6" (E,S)=55.47 ___EASEMENT TO BENEFIT LOT A - --------- I' Q 23'-6" PVC 0 0.709 s� No ---- S ruurvu rctenn ec----'-'------- - - - - ----- I 25 LF ELBOW CAP "LSA 22969" i /j 27'-6" PVC ti zs 10' SNO PUD 75'-6" PVC ® 0.7 % *6" BW VALVE �21� _ J N 7 I ®2.09 MIN. / EASEMENT so.00 BACKWATER VALVE DETAIL NOT PRO\r = e.o W _67• 60'°°� CONTRACTOR SHALL PROVIDE CITY NW45REPLACE SIDEWALK PER ° ° L INSPECTOR WITH PRODUCT CUT SHEET FO 6" SSCO WITH 12" CI ° -D- - -A LPIRLQR QINSTAL �TION. IF - COE TR-531, TYP LAMPHOLE COVER WITH - - D - - p - 0.5EXBOLSPER VALVE D ES NOT PROVIDE A CLEANOUT TEN - -D- - - -D- - - o�- -W - - SHALL BE INSTALLED IN CB-2. RIM=6 - - - - - - - - - - � 2.00± MATCH FG � y I 6 / Q W- - IE=55.00t e° o EXISTING WATER METER--�15" POLYPIPE h`� -"'1� -W� -W TO BE UPSIZED TO 1 " PAVEMENT REPAIR FOUND CASED "I WATER SERVICE LINE 29'-6" PVC 0 ti / 235.65'(C) 235.69'(R2) PER COE GU-410 I / 6" CONC PIPE WITH TRACER WIRE. 2.O/o MIN. DIRECTION PER CITY TACK IN 3/4" 1 - - - -�l- N PER COE WA-130 S S88'45'21"F. 450.00'@2) OF EDMONDS GIS IRON PIPE - - - �.� -� - - __ ! - / '/ CB-1 TYPE 1 PER COE STD SD-303 S88'45'21"E 356.30'(R3)(R4) S88'45'21"E 329.35'(C) 329.32'(R1)(R2) RIM=A57.5J± MATCH FG DALEY ST \ IE=51.77t REPLACE EXISTING CURB RAMP IE 6" PVC (N)=55.31 NEW SIDE SEWER 0 PER COE DETAIL TR-540 IE 12" CONC. (E,W)=54.82 CONNECTION PER \ / ► /O NOTE.• COORDINATE INSTALLATION COE SS-202 AND RESTORATION WITH CITY INSPECTOR TO MAXIMIZE CAPTURE OF STORM FLOWS AT THIS LOCATION. h° NOTE: 3' OF HORIZONTAL ti _ SEPARATION BETWEEN WET =� AND DRY UTIL171ES (LE. POWER, PHONE, GAS, CABLE, ETC.) HOUSE FOUNDATION SEE ARCHITECTURAL & STRUCTURAL PLANS STORMWATER PUMP SYSTEM NOTES 1) THE PUMP SYSTEM MUST BE PRIVATELY OWNED AND MAINTAINED. THE PUMP SYSTEM SHALL HAVE A DUAL PUMP (ALTERNATING), UNLESS OTHERWISE APPROVED. 2) THE PUMP SYSTEM SHALL BE USED TO CONVEY WATER FROM ONE LOCATION OR ELEVATION TO ANOTHER WITHIN THE PROJECT SITE, PRIOR TO GRAVITY DISCHARGE TO THE PUBLIC STORM DRAINAGE SYSTEM. 3) THE PUMP SYSTEM MUST BE CONNECTED TO AN EMERGENCY BACK-UP GENERATOR. 4) ALL PUMPS SHALL BE EQUIPPED WITH AN EXTERNAL VISUAL AND AUDIBLE ALARM SYSTEM. 5) THE PUMP SYSTEM SHALL NOT VIOLATE ANY CITY ORDINANCES OR CODES. 6) NO FORCED MAIN SYSTEM SHALL BE DIRECTLY CONNECTED TO THE CITY'S STORM CONVEYANCE. ALL FORCED MAIN FROM PUMP SYSTEMS SHALL CONNECT TO A CB OR YARD DRAIN ON SITE AND GRAVITY TO THE STORM SYSTEM IN THE RIGHT-OF-WAY. PUMP CONTROL SYSTEM: PROVIDE A SJE-RHOMBUS 1221 SINGLE PHASE DUPLEX ALTERNATING PUMP CONTROL PANEL WITH OVERRIDE CIRCUIT BREAKER. PUMPS TO OPERATE AS A STANDARD LEAD, LAG, ALTERNATING STYLE OF SYSTEM. PANEL TO BE MOUNTED INSIDE GARAGE. PUMPS, PUMP BASIN, AND CONTROL PANEL ARE AVAILABLE AT HD FOWLER. PH. (425) 746-8400 PROVIDE POWER CONNECTION AND CONTROL SWITCH WIRING TO CONTROL BOX IN GARAGE VIA APPROPRIATE CIRCUIT BREAKER, CONDUIT AND JUNCTION BOX FROM SUMP STRUCTURE. CONSTRUCT AND INSTALL PER ELECTRIC CODES AND MFR. REQ'TS BASEMENT FINISHED FLOOR ° SOLID CAST IRON LID POWER/CONTROL RIM ELEV=MATCH FIN. CONDUIT GRADE (ALTERNATIVE 8 (WATERTIGHT ORENCO PVC PUMP CONN.) BASIN COVER) *10 N ^ U \ N /�\/ �\ \ CONNECT 1-112" ° �� ��SUMP ��\ TO CB OR AREAS Emil \//� //�/ DRAIN "e,/�� PROVIDE UNION a //�j FOR SERVICING PUPS INDIVIDUALLY /I"--EACHKPUMPVALVE FOR 24" RCP PIPE (SEAL INTERIOR TO PREVENT LEAKAGE) \/\\/ a a (ALTERNATIVE: ALRIBBEDPUMPBASIN) TRN• N BOTTOM OF F0077NG ECO PVC �REFERENCE EL Y/\ EV.= +0.00' 4" I ^1 14..y N - I�J.Se, GOULDS MODEL LSP0311 DUPLEX ALTERNATING SUMP PUMP OR EQUAL jA.1 HIGH WATER ALARM LAG PUMP a �� ON ELEV.= -1.00' LEAD PUMP ON ELEV.= -2.00' PUMP o o � - STOP ELEV.= -3.00' BOTT. EPRE-CAST OPLUG FO 0 TING DRAIN SUMP PUMP SYSTEM DETAIL NOT TO SCALE R/W F� R/W 15' PERMEABLE PAVEMENT EXISTING GRAVEL i EXISTING FENCE I I (TO BE REPLACED) (BETWEEN DRI VEWA YS) I POROUS HMA/WMA I- 2:1 Max (cur). PROPOSED J • - ,..- ,.., ,, ....... �..- -• . . COMMUNICATION BASE COURSE UTILITIES SUBGRADE PERMEABLE PAVEMENT SECTION SHALL BE IN CONFORMANCE WITH COE DETAIL SD-621 & SD-627 ALLEY CROSS SECTION LOOKING WEST NOT TO SCALE STORM DRAIN STRUCTURE TABLE SEWER STRUCTURE TABLE (D STORM DRAIN MANHOLE RIM EL=62.93' (S) 10" CONC. I.E.=58.35' (W) 12" CONC. I.E.=58.31' 02 STORM DRAIN MANHOLE RIM EL=51.56' (E) 12" CONC. I.E.=48.88' (SW) 12" CONC. I.E.=47.06' (NE) 12" CONC. I.E.=47.01' 10 SEWER MANHOLE RIM EL=63.10' (N) 8" PVC I.E.=52.91' (E) 10" CONC. I.E.=52.19' (W) 10" CONC. I.E.=52.10' SEWER MANHOLE RIM EL=51.81' (E) 10" CONC. I.E.=45.67' (SW) 12" CLAY I.E.=45.63' (N) 10" CONC. I.E.=46.83' BUILDING DEPARTMENT CONSTRUCTION NOTES 1. NO EXCAVATION OR FILL IS AUTHORIZED TO ENCROACH UPON A NEIGHBORING PROPERTY WITHOUT EXPLICIT AUTHORIZATION BY THE ADJACENT PROPERTY OWNER. 2. ANY CAST -IN -PLACE RETAINING WALL 4 FEET AND GREATER, MEASURED FROM TOP OF WALL TO TOE, OR ANY RETAINING WALL THAT HAS A SURCHARGE ON IT, SHALL HAVE A SEPARATE BUILDING PERMIT. J. A SEPARATE DEMOLITION PERMIT IS REQUIRED PRIOR TO REMOVAL OF ANY EXISTING STRUCTURE(S). GENERAL INFILTRATION SYSTEM NOTES CALL 3 WORKING DAYS BEFORE YOU DIG • 811 _ UTILITIES UNDERGROUND LOCATION CENTER (lD, MT, ND, OR, WA) ELECTRIC - RED SEWER - GREEN GAS/OIL - YELLOW SAFETYPRECAUTION SHALL BE IMPLEMENTED BY SURVEY -PINK TEL/CATV-ORANGE PROPOSED -WHITE CONTRACTOR(S)ATALL TRENCHING INACCORDANCE WITH CURRENT OSHA STANDARDS WATER -BLUE 1. THE INFILTRATION TRENCH MUST BE CONSTRUCTED LEVEL AND PARALLEL TO EXISTING CONTOURS. NATIVE VEGETATION SHALL BE MAINTAINED DOWNHILL OF THE INFILTRATION TRENCH AS MUCH AS POSSIBLE. ( 2. TRENCH LOCATION IS SCHEMATIC AND ALIGNMENT SHALL BE FIELD ADJUSTED TO MATCH EXISTING CONTOURS AND TO AVOID TREES. 3.IN THE EVENT OF ADJACENT TRENCHES, A MINIMUM OF 5' SEPARATION SHALL BE PROVIDED. 4. A MINIMUM OF 6" OF SOIL COVER SHALL BE PROVIDED OVER TRENCH. 5. TRENCHES SHALL BE FILLED WI TH UNIFORML Y GRADED WASHED GRA VEL WI TH NOMINAL SIZE FROM %" TO 1 X" DIAMETER. 6. TRENCH TO BE CONSTRUCTED IN ACCORDANCE TO THE DETAILS, ELEVATIONS, AND GEOMETRIC DATA PROVIDED. CHANGES TO THE CONFIGURATION OR LAYOUT SHALL BE APPROVED BY THE ENGINEER PRIOR TO IMPLEMENTATION IN THE FIELD. 7. THE INFILTRATION SYSTEM SHALL NOT BE PLACED INTO OPERATION UNTIL SITE WORK IS COMPLETED AND THE SITE IS COMPLETELY STABILIZED (I.E. WELL ESTABLISHED GRASS, STRUCTURES COMPLETED, AND GRAVEL DOWN, PARKING PAVED, ETC.). 8. USE OF THE INFIL TRA TION SYSTEM PRIOR TO COMPLETELY STABILIZING THE SITE IS LIKELY TO REDUCE THE CAPACITY OF THE SYSTEM TO PERFORM AS DESIGNED. STORM DRAIN GENERAL NOTES 1. A PRE -CONSTRUCTION CONFERENCE SHALL BE HELD PRIOR TO THE START OF CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL NECESSARY PERMITS PRIOR TO CONSTRUCTION. 2. BEFORE ANY CONSTRUCTION MAY OCCUR, THE CONTRACTOR SHALL HAVE PLANS WHICH HAVE BEEN SIGNED AND APPROVED BY THE CITY OF EDMONDS PUBLIC WORKS DEPARTMENT, OBTAINED ALL CITY, COUNTY, STATE, FEDERAL AND OTHER REQUIRED PERMITS, AND HAVE POSTED ALL REQUIRED BONDS. J. ALL STORM DRAINAGE IMPROVEMENTS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE CITY OF EDMONDS PUBLIC WORKS STANDARD PLANS AND POLICIES AND THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION, PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA). 4. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL, ALL CHANGES SHALL BE SUBMITTED TO THE CITY. 5. A COPY OF THE APPROVED STORM WATER PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 6. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR SIMILARLY STABILIZED TO THE SATISFACTION OF THE CITY OF EDMONDS DEPARTMENT OF PUBLIC WORKS FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. 7. MINIMUM COVER OVER STORM DRAINAGE PIPES IN ROW OR VEHICULAR PATH SHALL BE 18 INCHES, UNLESS OTHER DESIGN IS APPROVED. 8. CONSTRUCTION OF DEWATERING (GROUNDWATER) SYSTEMS SHALL BE IN ACCORDANCE WITH THE APWA STANDARD SPECIFICATIONS. 9. ALL TRENCH BACKFILL SHALL BE COMPACTED TO 95 PERCENT DENSITY IN ROADWAYS, ROADWAY SHOULDERS, ROADWAY PRISM AND DRIVEWAYS, AND 85 PERCENT DENSITY IN UNPAVED AREAS. ALL PIPE ZONE COMPACTION SHALL BE 95 PERCENT. 10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARDS, SAFETY DEVICES, PROTECTIVE EQUIPMENT, CONFINED SPACE PROTECTION, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. 11. APPROXIMATE LOCATIONS OF EXISTING UTILITIES HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR CONVENIENCE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF EXISTING UTILITY LOCATIONS WHETHER OR NOT THESE UTILITIES ARE SHOWN ON THE PLANS. THE CONTRACTOR SHALL EXERCISE ALL CARE TO AVOID DAMAGE TO ANY UTILITY. IF CONFLICTS WITH EXISTING UTILITIES ARISE DURING CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE CITY CONSTRUCTION INSPECTOR AND ANY CHANGES REQUIRED SHALL BE APPROVED BY THE DEVELOPMENT ENGINEER PRIOR TO COMMENCEMENT OF RELATED CONSTRUCTION ON THE PROJECT. 12. THE UNDERGROUND UTILITY LOCATION SERVICE SHALL BE CONTACTED FOR FIELD LOCATION OF EXISTING UTILITIES PRIOR TO ANY CONSTRUCTION. THE OWNER OR HIS REPRESENTATIVE SHALL BE CONTACTED IF A UTILITY CONFLICT EXISTS. FOR UTILITY LOCATION IN KING COUNTY, CALL 811. THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT UTILITY LOCATES ARE MAINTAINED THROUGHOUT THE LIFE OF THE PROJECT. 13. OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING TRAVELED ROADWAY SHALL BE BACKFILLED ONLY WITH 5/8" MINUS CRUSHED ROCK AND MECHANICALLY COMPACTED (UNLESS OTHERWISE APPROVED BY THE CITY). CUTS INTO THE EXISTING ASPHALT SHALL BE NEAT LINE CUT WITH SAW OR JACKHAMMER IN A CONTINUOUS LINE. A TEMPORARY COLD MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND COMPACTION. A PERMANENT HOT MIX PATCH SHALL BE PLACED WITHIN 30 DAYS AND SHALL BE A MINIMUM OF 1" THICKER THAN THE ORIGINAL ASPHALT WITH A MINIMUM THICKNESS OF 2". 14. ALL DAMAGES INCURRED TO PUBLIC AND/OR PRIVATE PROPERTY BY THE CONTRACTOR DURING THE COURSE OF CONSTRUCTION SHALL BE PROMPTLY REPAIRED TO THE SATISFACTION OF THE CITY CONSTRUCTION INSPECTOR BEFORE PROJECT APPROVAL AND/OR THE RELEASE OF THE PROJECT'S PERFORMANCE BOND. 15. GROUT ALL SEAMS AND OPENINGS IN ALL INLETS, CATCH BASINS, AND MANHOLES. RESUB REVISION Nov 05 2021 Nov 05 2021 CITY OF EDMONDS CITY OF EDMONDS DEVELOPMENT SERVICES DEVELOPMENT SERVICES DEPARTMENT DEPARTMENT APPROVED FOR CONSTRUCTION ONDS STORMWATER ENGINEERING DIVISION BY. REVISION ONLY APPROVED AS NOTED CITY I� 1/23/2021- o P� w > �1 - a o n �N z 'Is 0 0 Q 00 o -> w z � cn ul z z 0 Z z w_ J U O U C, F- U w Q z w Q z F- C)fLLJ 0 0 Lu m a o a o U) w U) w Of Of w w CV I cV I N I N I cV olNI'INI070I� udm m J J J J J Y Y Y Y Y Y U nz W z H-I z W Q HE­4-I cn W C\1 � CV �CD z� W � Q 00 o 00 00 ,�, CV N V) p co .01 w U J 0 0 0 N O T 0 u cr LL Q~z aa�J WSJ WLLI o H Of Ld o w LL-I 00 00 �QW_jP�� W p M 5U)a I m>_�� > cr W w J�� O Q w o o� �Z crU)Ng� a0CL,�o.� c c w w WWWn NV/ �W CL SHEET 3 of 5 JOB No. SEE A,PPLIWLE STANDARD DETAILS FRAME AND CRATE �� * COR RUOATE13 POLYETHYLENE S70 RM SEWER RIPE 2", 4", 16", OR 12" NOTES: 1. CATCH BASINS SMALL BE CONSTRUCTED IN A=RDANCE WITH WSOOT STANDARD SPECIFICATION 9-05.50(3). 2, AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WELDED 'WIRE FABRIC HAVING A MIN. AREA OF 0,12 SQUARE INCHES PER FOOT MAY BE USED. WELDED WIRE FABRIC SHALL COMPLY TO AST ! A497 (AASHTO M 221). WIRE FABRIC SHALL NO BE PLACED IN KNOCKOUTS. 3. APPLY 1`40f4—SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINIaE. RISERS AND FRAMES. 4. ROUND KNOCKOUTS MAY BE ON ALL 4 SIDES, WITH MAX DIAMETER OF 2O", KNOCKOUTS MAY BE EITHER ROUND OR "D" SHAPE. 5. THE MAX DEPTH FTROM THE FINISHED ORAOE TO THE -PIPE INVERT' IS 6, THE TAPER ON THE SIDES OF THE PRE -CAST BASE SECTION AND RISER SECTION SHALL NOT EXCEED 1/2-/FT. 7, CATCH BASIN FRAME AND GRATE SHALL BE IN AOCORDANCE WITH STANDARD SPECIFICATIONS. MATING SURFACES SHALL BE FINISHED TO ASSURE NON --ROCKING FIT WITH ANY COVER -POSITION. (MEASUREMENT AT THE 70P OF THE EASE) S. VERTICAL EDGE OF RISER SHALL NOT BE MORE THAN 2" PRE>vA T BASE SE TION -F ROM VERTICAL EDGE OF OATCH BASIN WALL, RISER SECTION CITY OF EDMONDS PUBLIC WORDS DEPARTMENT PIPE ALLOWANCES -PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIKE 15" CPSSP" 12" (W8D4T STD SPEC SI-OEi.20) SOLID WALL PVC 1a" (WSIDOT STD SPED P1�Df1LE MALL PVC 15� (WSI�T STD SPED S-O;S,12(211 -REVISION DATE JANUARY 20118 CATCH BASIN TYPE I APPROVED BY; R. EH+GLI8H /// .--"DISHED" CAST IRON GRATE r 6" DIAMETER OUTLET PIPE i r"irwnrir wvi ivri (POURED IN PLACE) .r;`oe NOTES 1, FOR USE IN NON -TRAFFIC AREAS ONLY, SUCH AS ENCLOSED YARDS IN PRIVATE RESIDENCES AND ENCLOSED PLAY AREAS IN SCH001- GROUNDS, 2, FOR USE WITH 6"" PIPES AND SMALLER, AND DEPTH LESS THAN 18"'. 3, LAST STRUCTURE BEFORE ROW HAS 18" MIN. SUMP DEPTH STANDARp QETAIL SD-30 LAST REVIUD: 1/2019 die SQUARE TYPE FLAW CONTROL. � 4.;'S',� STRUCTURE _ NON -SHRINK GR0LIT PVC PIPE* 1'_O" U1Ak CONTnL DEVICE EL* ASSEMBLY TO BE COUPLING PVC PIPE � STUB* I -REMOVABLE FROM INSIDE THE FCS (OPTIONAL) v I PVC PIPE* — -IF-- �r SET SCREW TO I 4 PREVENT ROTATION ' INVEIRT*GASKET rr (IYP) � PVC PIPE M I ER* PVC ADAPTER* Wj - ° CROSS* DOUBLE GASKET I AND ADHESIVE BONDED SAND FINISH ON EXTERIOR, MIN 7" LONG DRILLED ORIFICE CAULK SPACE BETWEEN IN P' II+l51QE � Pt.uB PVC ADAPTER AND PIPE STUB! CONNECTION # CONML DE�110E DETAIL ORIFICE DIAMETER'" =0.50" DRILLED A OR1F10E CONNECTION AND LADDER OR HAND HOLDS �- DIAO CONTROL DEVICE POLYPROPYLENE P°VC INSIDE (SEE DETAIL A) CAP PLUG* r , OUTLET PIPE. II I CINCH ANCHOR ALLOWABLE OUTLET LOCAI' O (18cr to 315') WIRE TROPE CUP (�� ELEV=59.50t ®FINISHED IoRADE ;TCi� BASIN TYPE II 'q DEFORMED V-NOTCH 'WEIR AS NEEDED* -PER �C�►y3�E STa DTL SD-ELEV=57.50 3/8" DEL 0 OVMFLOW EL,E; ' ROD (S OR ALUMINUM) + SUPPORT (2 IREC'1)) a r r rrl 1 A I A I neal�Yf�! e 'fir LENGTH T4 FIT INVERT* 1'-CI MIN �' PVC PIPE 81; ELEV=56.00 ® INVERT - , 1 "-8" MAX C� FLOW CONTROL STRUCTURE CONTROL DEVICE SEE DETAIL A �+ DETENTION PIPE PIPE SUPPORT (LENGTH, DIAMETER, DETAIL B DIA * MATERIAL TYPE)* 93 LF - 18" DIAMETER, N-12 FLOW CONTROL MU�CMIRE DETENI)ON PIPE. SEE SHEET 2 �N W/ TYPE 2 CATCH BASIN FOR GEOMETRY ALL £SICNS (DETAIiEFRELA NOTES: SHEAR GATE WOULD OAPPLY THERWISEO APPLY} * SPECIFIC DESIGN INFORMATION AS INDICATED ON APPROVED CONSTRUCTION DRAWINGS. INVERT OF DETENTION PIPE 1N STRUCTURE SHALL 13E EQUAL TO OR ♦AIGHEfR THAN THE INVERT OF THE OUTLET PIPE. PRIVATELY -OWNED CONTROL STRUCTURES SHALL NOT BE PLACED IN CITY RIGHT-OF-WAY. REVISION [SATE FLOW CONTROL JANUAIRY 2018 CITY �F EDMONDS STRUCTURE STANDARD PUBLIC WORKS (FCS) ' DEPARTMENT DETAIL Z, t ,1 S D -- 3O 1 APPROVED BY: R. ENOUSH 10, EXPANSION DUMMY JCIINT JOINT d a di e' 10, O.C. _I�, ELM OEA (NOT TO 'SCALE) 5' MIN FULL DEPTH 1 /2" EXPANSION CURB/GUTTER �J1riINT MATT=RIAL SEE R- STD 2. MAX DTL TR-B2O , dap 0 4" :,a qz d 1 /" R `. G A 4 All UK 4 ww'N) - , YARD DRAIN DETAIL ' O" MIN NATIVE B MINUS CSTC ON NATIVE BEARING SOIL SECTIO I MEW SEE NOTE T! NOTES: (NOT TO SCALE) 1. CITY INSPECTION RFOUNREID ON FORM WORK PRIOR TO POUR. 2, CONCRETE SHALL 13F CLASS 3000. 3, FINISH SHALL BE LIGHT 13JROQM. 4, SIDEWALK THICKNF� SHAI-L BF 4'. B, SIDEWALK THICKNESS AT DfRIVE�WAYS SHALL BE 8' THICK, 6, CURB AND GUTTER SHALL BE POURED SEPARATELY FROM SIDEWALK, 7. LIDS FOR JUNCTION BOXES AND UTILITY 'VAULTS SiaALL BE NON-SKID AS SPECIFIED BY ENGINEEIR. 8, SEE COE SM DTL TR-E�50 FOR POSSIBLE TROT BARRIER INSTALLATION, 0. SUBGRADE SHALL BE COMPACTED TO 4% MAXIMUM DENSITY, 10, ALL EDGES WITH EXPANSION JOINTS SHALL HAVE � RADIUS CITY OF EDMONDS PUBIC WORKS DEPARTMENT CONCRETE SIDEWALK APPROVED BY: R, ENOUSH REVISIDN (DATE JUNE 201E STANDARD DETAIL TR-5 1 RING AND COVER PER COE STD DTL OU-420 FOR CORRO AND SPLASH LINE ONLY: FRAME AND CRATE PER COE SM DTL SD-Z20 SERIES S" MIN 18" MAX TOP SLAB 2"-S" CONCRETE RISERS USING NON -SHRINK GROUT, PROVIDE SMOOTH FINISH INSIDE AND OUT HANDHOLDS (2) SEE CLUE STD DTI, OU-423 POLYPROPYLENE SAFETY STEP/LADDER 12" O,C, (SEE NOTE 6 & 7) SAND COLLAR OR KCR-N-SEAL AROUND PIPE PRECAST BASE AND INTEGRAL RISER �. 1, CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.60(3), 2. HANDHOLDS IN ADJUSTMENT SECTION SHALL HAVE 3" MIN CLEARANCE. STEPS IN CATCH BASIN SHALL HAVE 8" MIN CLEARANCE. 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ,ALL JOINTS, RINGS, PICK HOLES, RISERS AND FRAMES. ALL PRECAST CONCRETE SHALL BE CLASS 4000, 4. KNOCKOUT OR MOUT HOLE SIZE SHALL EQUAL PIPE OUTER DIAMETER PLUS CATCH IRASIN WALL THICKNESS. MAX HOLE SIZE SHALL SE 36" FOR 48" CATCH BASIN, 42" FOR 54" CB, 48'" FOR 60" CB, 60" FOR 72" CS, 1134" FOR OV CB, MIN DISTANCE 13ETWEEN HOLES SHALL RE 8" FOR 48"0 54°', AND 60" CB; 12" FOR 72" AND W CB. S. CATCH BASIN FRAMES AND GRATES OR COVERS SHALL SE IN ACCORDANCE WIT+•I SEC 7.05 OF THE WSDOT STANDARD SPECIFICATIONS. 6. STEP AND LADDER MAY BE USED IN LIEU OF POLYPROPYLENE SAFETY STEPS, SEE COE STD DTL GU-423, 7. STEP ANTI I -A OM SHALL BE ORIENTED TO AVOID INS7AL-L.ATION ASAVE PIPE, 1 'z t , 18"A" rSD DATE CITY OF EDMONDSLCCH BASIL d TYPE II 2021 60 PUBLIC WORKS72", & � 96 � STANDARD DEPARTMENT L E;D Imo,' R, F PIGUSH D O 8-1 j2" •� 1 ERTTER Ri18 y 0,a FT FT 2' MIN SAWCUT SEE NOTE 10 18" STANDARD I >5"-5/5 MINUS CSTC SEE N : 11 J MIND CSTC AST ND„ "RD TYPE ' e :QURja/GUTTER (NCT TO SCALE) HMA 4" OR MATCH EXISTING, WHICHEVER IS GREATER SEE NOTE 12 1, CITY' INSPECTION REQUIRED ON FORM WORK PRIOR TO POUR. 2, FORMS SHALL BE TRUE TO LINE AND GRADE AND SECURELY STAKED. 3, EXPANSION JOINTS SHALL BE PLACED ADJACENT TO ANY STRUCTURE. 4, EXPANSION ,JOINTS SHALL BE EVERY 10 FEET, 5, EXPANSION JOINTS SHALL HAVE 1/2" TO 5/8" WIDE PREMOLDED JOINT FILLER. -6, CONCRETE SHALL BE CLASS 3000. 7, FINISH SHALL BE LIGHT BROOM. 8, CURB SHALL 13E SPRAYED WITH CLEAR CURING; COMPOUND OR SHALL BE COVERID3 AND KEPT MOIST FOR 72 HOURS. -9, REMOVAL/REPLACEMENT OF CONCRETE CURB .6HALL BE FROM EXPANSION TO EXPANSION ,JOINT, UNLESS O1'FIELRWISE DIREOTED 13Y CITY ENGINEER. 10, A 2-FT MINIMUM ASPHALT SAWCUT MAY BE RE-QUIRED AS DETERMINED BY CITY ENGINEER, 11, CURB/GU`TTEER SHALL BE 1 B" OR AS DIRECTED BPI' CITY ENGINEER, 12. ALL VERTICAL EDGES SHALL BE TACKED, IREVIrMON BATE CONCRETE CURB JANUAIRY 2018 F. CITY OF EDMONDS AND GUTTER r PUBLIC WORKS STANDARD DEPARTMENT DETAI L s 1. 1�°fl APPROVED BY: It. I N-SUS14 TR-'52O MECHANICAL PLUG - EXTEND CLEANOUT 2" ABOVE DESIGN PONDING ELEVATION OR PER PLAN 4" STREAMBEU COBBLES PER W$DOT 9--p3.11(2) DESIGN PONDING ELEVATION SOIL TIGHT 45' BEND 1. WYE SOIL TIGHT COUPLER UNDERDRAIN PIPE,-\ PER PLANS rU RES U B Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVISION Nov 05 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TRAFFIC RATED. CIRCULAR LOCKING CAST VALVE BOX PER ASPHALT/ MANUFACTURER CONCRETE RECOMMENDATIONS, SEE NOTES 1 AND 2 N MECHANICAL PLUG AOO VALVE BOX EXTENSION OR SOIL PIPE AS NECESSARY TO ACCOMMODATE O.D. OF RISER PIPE II CLEANOUT COVER IN PAVED AREA Hh LAWN/ NIPS PRO SERIES VALVE LANDSCAPE BOX WITH LOCKING =IN)COVER, OR EQUAL. SEE � NOTES 1 AND 2. 4" (MIN) Aw PLUG OR CONTINUED UNDER DRAIN CRUSHED SURFACING MECHANICAL PLUG CONNECTION TOP COURSE (CSTC) CLEANOUT PER wswr 9-w.9(3) (SHOWN WITHIN BIORETENTION FACILJTY) CLEANOUT COVER IN LANDSCAPE AREA GENERAL NOTES: 1. CLEANOUT PIPE SHALL BE SAME SIZE AND MATERIAL AS UNDERORA14 PIPE. 2. CLEANOUT SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 3- ALL FITTINGS SHALL BE SOIL TIGHT. 4. CLEANOUT RISER TOP SHALL BE LOCATED OUTSIDE OF PONDING AREAS WHERE POSSIBLE. NOTES: 1. CLEANOUT COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "DRAIN CLEANOUr." "CLEANOUT," "CO," OR SIMILAR. 2. TRAFFIC RATED LID REQUIRED IN AREAS WITH VEHICULAR LOADING. REVISION DATE _ CITY OF EDMONDS CLEANOUT DRAINAGE DECEMBER 2017 CLEANOUT PUBLIC WORKS STANDARD DEPARTMENT D ETAI L t. 1890 APPROVED BY: R. ENGLISH S D— 61 9 BY. APPROVED FOR CONSTRUCTION MONDS STORMWATER ENGINEERING DIVISION APPROVED AS NOTED REVISION ONLY 1 /23/2021 >LJ �M m w 0 H- C)Z IZ U J � U � U o 0:: o � � o � w N N I I 0 in 04 N N z Hn�y-I W W 7W Z C z W r- �W 11 T� V I� cn W N W o z� w¢ Q� Y) = - o 00 O •� N N � N -- d• U. V/ CO I co JHZ < co C) uj uj � Q ` N ■ W W � 00 ZJ W�Na OQ �p WLd Ll) �_j V�>wQo� 0 0CC �o NMoN � z - c) LLI Ld U/ m Q pW W Y Q a. SHEET 4 of 5 JOB No. z z SEWER STUB SHALL 13E LOCATED 10 INSIDE Ph�CPEFkT`P LINE �e STAKED. PLACE 2"x'1•" TIMBER AT END OF SIDE SEWER STUB AND CUT TO LENGTH-1 Tt3 ENSURE ;3 FEET E7�TEh1135 AB�3VE GRADE, PAINT Ti3R 18 INCHES WHITE, IN 3 INCH HIGH LETTERS RESIDENCE STENCIL THE NUMBER OF EVEN FEET FR�3tul GROUND ELEVAT1QN T�i THE SEWER STUB INVERT. 3 GAUGE WIFE T�3 BE DOUBLE WRAPPED AROUND PIPE AND '� x � 3TA}�I; AT L {3R ABOVE FINISHED GLADE. WITH 4me 5' � .,�,.. SEND AND � i' DAP, CLEAN�ILlT (MAX) (� ri LOCKING G1.EAN�iL>T D�11/ER JOB No. (IF ST#!B F�?I� FlITI,Jf#E DEVELOPMENT? LL ) PER COS 17� SEE NOTE 3 2 1,i71�1�1N�S COVER CD G�I�AN�7lJT DETAIL Pc�a�SIS DETAILS I'�E1>�I LATERAL SEWER SS-20It L0 0 A oo LLj 00 7 oo CURB DTL C TY%V CITY EDMONDS PES DIRECTIONS). CL