APPROVED BLD ENG STM RESUB 5-13-21 REVISED Lot3 Civil PlansJ LU 0 14TH WAY SW 226TH ST SW y 0 J PROJECT �s SITE y500 �P S C VICINITY MAP N.T.S WASHINGTON STATE CODE THE SUPREME COURT OF WASHINGTON ISSUED A RULING ON DECEMBER 29, 2016 REGARDING THE "VESTING" OF STORMWATER REGULATIONS. THIS RULING UPHOLDS THE DEPARTMENT OF ECOLOGY'S REGULATIONS FOR APPLICATION AND CONSTRUCTION DATES FOR PROJECTS WITH STORMWATER REQUIREMENTS. THE CITY OF EDMONDS HAS RECEIVED CLARIFICATION FROM THE DEPARTMENT OF ECOLOGY ON WHAT THIS RULING MEANS FOR DEVELOPMENT APPLICATIONS SUBMITTED PRIOR TO LOCAL STORMWATER CODES BEING ADOPTED. THE STORMWATER CODES IN EFFECT AT THE TIME THE APPLICATION FOR A PLAT/SUBDIVISION IS SUBMITTED APPLY TO ALL SUBSEQUENT BUILDING PERMITS IF STORMWATER IS BEING ADDRESSED AT THE SUBDIVISION/PLAT LEVEL. IF THE SUBDIVISION INCLUDED RESTRICTIONS OR REQUIREMENTS FOR THE INDIVIDUAL LOTS, (E.G. MAXIMUM IMPERVIOUS SURFACE, LID BMP'S), THOSE REQUIREMENTS SHOULD BE RECORDED FOR EACH LOT AND MUST BE ENFORCED WHEN THE INDIVIDUAL LOT IS DEVELOPED. UNDER THE MUNICIPAL STORMWATER PERMITS THE ONLY PLACE THAT THE RECENT SUPREME COURT DECISION COMES INTO PLAY IS IF THE DEVELOPER DOES NOT START CONSTRUCTION ON THE PLAT/SUBDIVISION UNTIL AFTER JANUARY 1, 2022. FOR THE PURPOSES OF THE MUNICIPAL STORMWATER PERMITS BOTH "APPLICATION" AND "START CONSTRUCTION" ARE DEFINED IN THE PERMITS. APPLICATION MEANS AT A MINIMUM, A COMPLETE PROJECT DESCRIPTION, SITE PLAN, AND IF APPLICABLE SEPA CHECKLIST. START OF CONSTRUCTION MEANS AT A MINIMUM, THE SITE WORK ASSOCIATED WITH AND DIRECTLY RELATED TO THE APPROVED PROJECT HAS BEGUN. FOR EXAMPLE: GRADING THE PROJECT SITE TO FINAL GRADE OR UTILITY INSTALLATION. LANGUAGE SHALL BE INCLUDED ON THE FACE OF THE RECORDING DOCUMENTS FOR THE PLAT/SUBDIVISION THAT STATES THE STORMWATER CODES IN EFFECT AT THE TIME OF APPLICATION FOR THE PLAT/SUBDIVISION SHALL APPLY, AS LONG AS CONSTRUCTION ON THE PLAT/SUBDIVISION STARTS PRIOR TO JANUARY 1, 2022. IF CONSTRUCTION DOES NOT BEGIN PRIOR TO THIS DATE, THE STORMWATER SYSTEM FOR THE PLAT/SUBDIVISION SHALL BE REDESIGNED TO COMPLY WITH CURRENT CODES. SURVEY DATUM VERTICAL DATUM: NAVD88 BENCHMARK: 2" BRASS DISK IN CASED CONCRETE MONUMENT IN CENTERLINE OF 100TH AVENUE WEST 600' NORTH OF INTERSECTION WITH SR 104/EDMONDS WAY, OPPOSITE THE SOUTHEAST CORNER OF CEMETERY PROPERTY. ELEVATION = 312.10 FEET. (WGS CONTROL POINT #22) TEMPORARY BENCHMARK AT REBAR & CAP (LS #9891) AT SOUTH PROPERTY CORNER. ELEVATION = ???.?? FEET. HORIZONTAL BASIS OF BEARING: N74000'00"E BETWEEN FOUND MONUMENTS ON 15TH STREET SW. EQUIPMENT USED: INSTRUMENTATION FOR THIS SURVEY WAS A 5 SECOND THEODOLITE AND AN ELECTRONIC DISTANCE MEASURING UNIT. PROCEDURES USED IN THIS SURVEY WERE FIELD TRAVERSE, MEETING OR EXCEEDING STANDARDS SET BY WAC 332-130-090. PORTION OF SECTION 25, TOWNSHIP 27 5., RANGE 03 W., W.M. 719 EDMONDS WAY -LOT 3 CIVIL CONSTRUCTION PLANS PARCEL# SITE DATA SITE ADDRESS: 719 EDMONDS WAY EDMONDS, WA 98020 SITE AREA: 7,952 SF (0.18 ACRES) ZONING: (RS-6) SINGLE FAMILY RESIDENTIAL SETBACKS: FRONT: 20' REAR: 15' INTERIOR: 5' BUILDING COVERAGE: 37% LAND USE: BS PROPOSED DENSITY: 6.5 DU/ACRE STSVV--, 5th FOUND TACK IN CONCRETE IN CASED IRON PIPE HELD \ 15'ACCESS EASEMENT • a Know what's beIow. Call before you dig. 10 5 0 10 SCALE: 1" = 10' \ TOLKSARAHM,, RAEBALDOTIMOTII A \\ 7I0 9000 00 5 �/ / / \ 30" DEC. \ #I90.3901�000t�0.5®0 \ ' � \ TEMPORARY PROJECT BENCHMARK j Q',000 \ \ I FOUND REBAR & CAP LS #9891 / y �� / �,\� \ ELEV 287.43 /\� / CONTRACTOR SHALL VERIFY /000 Q0 EXACT LOCATION AND ELEVATION 8 5' UTILITY \ EASEMENT \ 'III / 11�1111 ,� P .- m 1DS 1 1 PROPOSED SINGLE FAMILY �G, \ I �N 1 RESIDENCE \oy p2\\\ �S \ �o / 1 1 1 1 �1 1 ROOF AREA: 2,140 SF I \ FF 291.29 s 1 1 1 1 1 1 1 1 v 1 v i s \\ \ S \ \ \ \ \ EX WATER Ds/ SERVICE STUB \ \ \ \\ \ G 1 1 0\\ EX SSCO a \\ \ s ' \ 1 1 1 1 ` os�: \`\ tiII'�� 6sPN �� s IE289.28 \ \ \ a \ \ o'er. II III �i \ i \ \ \ \ EX GAS MAIN I 1\I \' s � / < O \ GENERAL GRADING NOTE PROVIDE POSITIVE DRAINAGE AT A MINIMUM SLOPE OF 1.0%, AWAY FROM STRUCTURES O.C.�\\ `EX SIDE SEWE�2 STUB \ JER/ BLED \ I \ III N! \� I I j GdPN 16� EX SSCO \ \ \ \ E 287.83DS EX STORM DRAINAGE \ \ FRENCH DRAIN FOR LOT 1 \ GENERAL GRADING \ \ \ \ \ \ \\ SEE GRADING NOTE \ \ \ \ EX SSCO \ \ 10SEWER 7 IE 283.53 \ \ \ EASEMENT \ EX SSCO \ \ \ \ \\ \ \ \ \ ZE 283.25 �� \ �S� UTILITY PURVEYORS WATER: OLYMPIC VIEW SEWER & WATER DISTRICT SEWER: CITY OF EDMONDS POWER: SNOHOMISH PUBLIC UTILITY DISTRICT Cable/TV: COMCAST/FRONTIER GAS: PUGET SOUND ENERGY STORM: CITY OF EDMONDS CONSTRUCTION HOURS CONSTRUCTION ACTIVITIES SHALL BE RESTRICTED TO THE HOURS BETWEEN 7 AM AND 6 PM, MONDAY THROUGH FRIDAY. WORK ON SATURDAYS SHALL BE RESTRICTED TO THE HOURS BETWEEN 10 AM AND 6 PM. NO WORK SHALL BE PERMITTED ON SUNDAYS OR FEDERAL HOLIDAYS. -EMC SECTION 5.30.110.13 PROJECT INFO OWNEIMLIENT. ENGINEER: SUI HING CHUNG BEYLER CONSULTING 18321 3RD AVE SW 5920 100TH ST. SW STE 25 SHORELINE, WA 98177 LAKEWOOD, WA 98499 TEL: 253-984-2900 SHEET INDEX C1.0 COVER SHEET / SITE PLAN C2.0 TESC PLAN C2.1 TESC NOTES & DETAILS C3.0 GRADING AND UTILITY PLAN C3.1 STORM DRAINAGE & UTILITY DETAILS APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION w Q 0 z O a U V7 w 0 d Ln N a� E 1Y +' O O U O 08 1LLL + Q Co *' W U) 3 C O�ON O 0_,0.. o0(1)_ N 0 OmMMc V in J 0. m ^, V! z z Z a `V W C7 a ZW W L7 W� V W z as Z — ,--, Ic ` J E a zy J J D �� zm W LL W■/� 0 of - _ z- �z V Z W W W J W �< U cd� r I U a �° � a U O M QD Q o O � J L\ oLn ti Q Q CL z LU J O W CIO-01 c_ O QLU ~ U m O 2 W LL1 O O U _ m c U Y W W Q W = U O O U U UJI 1� ' \ ILL O Z U 0 J m 5/11/2021 JOB NUMBER 16,00089 SHEET 1 OF 5 ci . 0 0 N 0 N w 0 01 LID PROTECTION ALL LID FACILITIES TO BE PROPERLY PROTECTED FROM CONSTRUCTION TRAFFIC. OVER EXCAVATION AND GEOTECHNICAL APPROVAL OF THE SUBGRADE WILL BE REQUIRED PRIOR TO PLACING ANY ROCK FOR INFILTRATION FACILITIES. DUST CONTROL • - 15ACCESS - - EASEMENT i - - \ \ Know what's below. \ Call before you dig. AIL 31C2.1 30" DEC.. 10 5 0 10 00 SCALE: 1" = 10' TEMPORARY PROJECT BENCHMARKCID \ \ FOUND REBAR & CAP LS #9891 /" L / \/- i ♦ \ I \ \ \ \ \ ELEV 287.43 - - - - / - / - \ \ ♦ \ \ \ \ \ \ \ \ \ \ CONTRACTOR SHALL VERIFY // W \ \ \ \ \ \\ EXACT LOCATION AND ELEVATION - , \ / - - \ UP 8.5' UTILITY \ r \ �'\ \ \ ♦ / �� - i �j \ EASEMENT I, \ �'Sr ��Oo /�� PROVIDE ORANG ROTECTIVE FENCING \ �� i �O\�O�O� m I AROUND INFILT TIONJFACILITY �\ 00 ?a" o \ \ m I \ \ \ \ STABILIZED CONSTRUCTION ENTRANCE rn m \ \> > \ S \ \ \ \ \ \ a4 ° ♦ / % o�Q�O�gQ��\� SEE DETAIL 2/C2.1 ` I - ' col \ > \O�D�QaO\ PLACE GEOFABRIC BELOW QUARRY SPALLS TO oOo(-) �f PROTECT INFILTRATION SOILS. Q\�OoaOo\O\Oa p ` GEOTECH TO SUPERVISE REMOVAL. o\ \ \ \ ° \\ �SS\\ �o� � o\\\O_c�\ PROVIDE ORANGE PROTECTIVE FENCING QoOOAROUND INFILTRATION FACILITY \ `� \ � J PREVENTATIVE MEASURES TO MINIMIZE WIND TRANSPORT OF SOIL SHALL BE IMPLEMENTED WHEN A TRAFFIC HAZARD MAY BE CREATED OR WHEN THERE IS THE POTENTIAL FOR SEDIMENT TO BE TRANSPORTED BY WIND. WATER IS THE MOST COMMON DUST CONTROL USED IN THE AREA. WHEN USING WATER FOR DUST CONTROL, THE EXPOSED SOILS SHALL BE SPRAYED UNTIL WET, BUT RUNOFF SHALL NOT BE GENERATED BY SPRAYING. EXPOSED AREAS SHALL BE RE -SPRAYED AS NEEDED. OIL SHALL NOT BE USED FOR DUST CONTROL. SOIL MANAGEMENT PLAN RETAIN, IN AN UNDISTURBED STATE, THE DUFF LAYER AND NATIVE TOPSOIL TO THE MAXIMUM EXTENT PRACTICABLE. IN ANY AREAS REQUIRING GRADING REMOVE AND STOCKPILE THE DUFF LAYER AND TOPSOIL ON SITE IN A DESIGNATED, CONTROLLED AREA, NOT ADJACENT TO PUBLIC RESOURCES AND CRITICAL AREAS, TO BE REAPPLIED TO OTHER PORTIONS OF THE SITE WHERE FEASIBLE. ALL AREAS SUBJECT TO CLEARING AND GRADING THAT HAVE NOT BEEN COVERED BY IMPERVIOUS SURFACE SHALL DEMONSTRATE THE FOLLOWING: 1) A TOPSOIL LAYER WITH A MINIMUM ORGANIC MATTER CONTENT OF 5% ORGANIC MATTER AND A PH FROM 6.0 TO 8.0 OR MATCHING PH OF THE UNDISTURBED SOIL. THE TOPSOIL LAYER SHALL HAVE A MINIMUM DEPTH OF EIGHT INCHES EXCEPT WHERE TREE ROOTS LIMIT THE DEPTH OF INCORPORATION OF AMENDMENTS NEEDED TO MEET THE CRITERIA. 2) USE COMPOST AND OTHER MATERIALS SHALL MEET WAC 173-350-100 SOIL QUALITY DESIGN CAN BE MET BY USING ONE OF THE METHODS LISTED BELOW. OPTION 1: LEAVE UNDISTURBED NATIVE VEGETATION AND SOIL, AND PROTECT FORM COMPACTION DURING CONSTRUCTION OPTION 2: AMEND EXISTING SITE TOPSOIL OR SUBSOIL EITHER AT DEFAULT "PRE -APPROVED" RATES, OR AT CUSTOM CALCULATED RATES BASED ON TESTS OF THE SOIL AND AMENDED. OPTION 3: STOCKPILE EXISTING TOP DURING GRADING, AND REPLACE IT PRIOR TO PLANTING. STOCKPILED TOPSOIL MUST ALSO BE AMENDED IF NEEDED TO MEET THE ORGANIC MATTER OR DEPTH REQUIREMENTS, EITHER AT A DEFAULT "PRE -APPROVED" RATE OR AT A CUSTOM CALCULATED RATE. OPTION 4: IMPORT TOPSOIL MIX OF SUFFICIENT ORGANIC CONTENT AND DEPTH TO MEET REQUIREMENTS. SEE SOIL AMENDMENT QUALITY NOTE ON THIS SHEET FOR AMENDED GUIDELINES REFER TO BMP T5.13 IN THE WESTERN WASHINGTON STORMWATER MANUAL FOR FURTHER DIRECTION. INN SEE CB PROTECTION ON DOWNSTREAM STORM SYSTEM CB \ OF SECTION 25, TOWNSHIP 27 S., RANGE 03 W., W.M. PROPOSED BUILDING FOOTPRINT FILTER FABRIC FENCE (SILT) , SEE DETAIL 11C2.1 Ex ssco SP �, / \j , \ \ S IE 289.28\r , \ \ \ \ \ \ \ \ \ o/\ C RRY \ \ EX SSCO 287.83 / 41 \ \ \ \IP,YOO ° CITY OF EDMONDS CONSTRUCTION SEQUENCE NOTES 1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT 425-771-0220, EXT. 1326. TWO DAY (48 HR) NOTICE IS REQUIRED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. 3. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATIONOUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS CITY ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED. 6. DEMOLISH EXISTING STRUCTURES 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 8. CLEAR, GRUB & ROUGH GRADE SITE. REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW) 9. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SITE. 11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR -, \ \\ \ 4 / ASP <\ 10' SEWER \ EASEMENT \ \EX \\\\�7 \ \ 283.5 283.53 EX SSCO IE 283.25 �`b�\\ \ \ \ \\\ ♦ \ \��� // I `\` \/ / \ \ \ \ o \ \ \ \ \ \ \ \ ��� �\ , ; i PLASTIC COVERING NOTES INSTALL CB PROTECTION ON DOWNSTREAM STORM SYSTEM CB SEE DETAIL 3/C2.1 SEE SHEET C2.1 FOR GENERAL NOTES AND DETAILS INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. ADD DISTURBED SOILS WILL BE COMPOST AMENDED PER BMP T5.13 1. PLASTIC SHEETING SHALL HAVE A MINIMUM THICKNESS OF 6 MILS AND SHALL MEET THE REQUIREMENTS OF THE STATE STANDARD SPECIFICATION SECTION 9-14.5. 2. COVERING SHALL BE INSTALLED AND MAINTAINED TIGHTLY IN PLACE BY USING SANDBAGS OR TIRES ON ROPES WITH A MAXIMUM 10-FOOT GRID SPACING IN ALL DIRECTIONS. ALL SEAMS SHALL BE TAPED OR WEIGHTED DOWN FULL LENGTH AND THERE SHALL BE AT LEAST A 12-INCH OVERLAP OF ALL SEAMS. 3. CLEAR PLASTIC COVERING SHALL BE INSTALLED IMMEDIATELY ON AREAS SEEDED BETWEEN NOVEMBER 1 AND MARCH 31 AND REMAIN UNTIL VEGETATION IS FIRMLY ESTABLISHED. 4. WHEN THE COVERING IS USED ON UN -SEEDED SLOPES, IT SHALL BE KEPT IN PLACE UNTIL THE NEXT SEEDING PERIOD. 5. PLASTIC COVERING SHEETS SHALL BE BURIED TWO FEET AT THE TOP OF SLOPES IN ORDER TO PREVENT SURFACE WATER FLOW BENEATH SHEETS. 6. PROPER MAINTENANCE INCLUDES REGULAR CHECKS FOR RIPS AND DISLODGED ENDS. APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: w Q z O a U w 0 Ln N W +N I= 0 Uu LL N C U) � o �Q0 W U) o� 3 �o�N O o� v 0.o3:Q _4) N � O U Lr) _j Q D z zz a E /d `v - W (7 a Z X W '^ V J I,TV W ti > K a W :2; D U) a o- J � J l 1�1 Z> J J m �Ea • � U, W lWL I W z O En N W z rz Z W 71 V � W J W �a �z U 2: �I = F DU ~ W a �° J a z Q J a U i O M z Q o O J W� a� C Ln qzz a Q z W U (n LU O° J � m Q c W � U W U U p W } O m Z U W � J � 4J04;J 4. �SSIONAL E�G� 5/I I/2021 JOB NUMBER 16.00089 SHEET 2 OF 5 CITY ENGINEERING DIVISION C2. 0 PORTION OF SECTION 25, TOWNSHIP 27 S., RANGE 03 W., W.M. i 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS: - CURRENT INTERNATIONAL BUILDING CODE (IBC) - 2019 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION - WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN (CURRENT EDITION) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE 3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL ASBUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL NATIVE BACKFILL MATERIAL P�I CITY OF EDMONDS GENERAL NOTES 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ONSITE 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (i.e. HEAVY EQUIPMENT, STOCKPILING). 14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN. 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 5% 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. 18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT TO THE DRAINAGE SYSTEM DOWNSTREAM OF THE SITE STORMWATER DETENTION SYSTEM. 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO JEFF.KOBLYK@EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER. FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS 1 WIRE MESH FENCE TO SUPPORT FILTER FABRIC co j %/�Y/�Yj x\)X BURY BOTTOM OF FILTER a MATERIAL 8" TO 12" 6' MAX NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ACTIVITY. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN [tER-900 DATE CITY OF EDMONDS FILTER FABRIC FENCE 018 FILTRATION SYSTEMS PUBLIC WORKS RD DEPARTMENT L APPROVED BY: R. ENGLISH FILTER FABRIC FENCE FILTRATION SYSTEMS CITY OF EDMONDS STD PLAN ER-900 NTS 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED. 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT RELOCATE OR ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL. 30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS TO EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES. 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 32. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE PRIOR TO BACKFILLING. 33. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND _LS A TH CITY. 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE. 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL BE COMPACTED TO 95%. COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE POLYETHYLENE PLASTIC FOAM AS A CUSHION BETWEEN THE UTILITIES. 37. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING. 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM. 40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION IN DE FULL WIDTH GRESS/EGRESS DETAIL NOTES: 1� THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE AND/OR INTO THE PUBLIC RIGHT-OF-WAY. O ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 4. INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. PROJECT SIZE MIN LENGTH OF (FEET) QUARRY SPALLS* < 1/4 ACRE 30 < 1 ACRE 50 < 3 ACRE 100 > 3 ACRE 100 *PROVIDE ATB OR ASPHALT TRANSITION WHERE FRONTAGE ROAD IS AN ARTERIAL. LENGTH TO BE DETERMINED BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN CITY OF EDMONDS STABILIZED CONSTRUCTION ENTRANCE PUBLIC WORKS DEPARTMENT APPROVED BY: R. ENGLISH STABILIZED CONSTRUCTION ENTRANCE CITY OF EDMONDS STD PLAN ER-901 NTS REVISION DATE JANUARY 2018 STANDARD D ETAI L ER-901 O O 0 O O O 0 O O O 0 O O O O O a�� O . O "8 a FILTERI SOCK WITH OVER FLOW HOLES (TYP) 4 CITY OF EDMONDS PUBLIC WORKS DEPARTMENT �St. 189" 2005 WASHINGTON STATE DOE BMP: CONCRETE HANDLING (REFERENCE 2005 WASHINGTON STATE DOE STORMWATER MANUAL) PURPOSE: CONCRETE WORK CAN GENERATE PROCESS WATER AND SLURRY THAT CONTAIN FINE PARTICLES AND HIGH pH, BOTH OF WHICH CAN VIOLATE WATER QUALITY STANDARDS IN THE RECEIVING WATER. THIS BMP IS INTENDED TO MINIMIZE AND ELIMINATE CONCRETE PROCESS WATER AND SLURRY FROM ENTERING WATERS OF THE STATE. DESIGN: CONCRETE TRUCK CHUTES, PUMPS AND INTERNALS SHALL BE WASHED OUT ONLY INTO FORMED AREAS AWAITING INSTALLATION OF CONCRETE OR ASPHALT. (CONCRETE TRUCK CHUTES, PUMPS, ETC. SHALL NOT BE WASHED IN SUBGRADE AREAS OF PROPOSED POROUS ASPHALT/INFILTRATION) WHEN NO FORMED AREAS ARE AVAILABLE, CONTAIN WASHWATER AND LEFTOVER PRODUCT IN A LINED CONTAINER. DISPOSE OF WASHWATER IN A MANNER THAT DOES NOT VIOLATE GROUNDWATER OR SURFACE WATER QUALITY STANDARDS. UNUSED CONCRETE REMAINING IN THE TRUCK AND PUMP SHALL BE RETURNED TO THE ORIGINATING BATCH PLANT FOR RECYCLING. HAND TOOLS SHALL BE WASHED OFF ONLY INTO FORMED AREAS AWAITING INSTALLATION OF CONCRETE OR ASPHALT. EQUIPMENT THAT CANNOT BE EASILY MOVED, SUCH AS CONCRETE PAVERS, SHALL BE WASHED IN AREAS THAT DO NOT DIRECTLY DRAIN TO A NATURAL OR CONSTRUCTED STORMWATER CONVEYANCES. WASHDOWN FROM AREAS SUCH AS CONCRETE AGGREGATE DRIVEWAYS SHALL NOT DRAIN DIRECTLY TO NATURAL OR CONSTRUCTED STORMWATER CONVEYANCES. GRATE FILTER SOCK WITH OVER FLOW HOLES (TYP) .N�C�1�■7_1yI►1 .g NOTES: CATCH BASIN 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. REVISION DATE TEMPORARY JANUARY 2018 SEDIMENT TRAP FOR CATCH BASINS STANDARD D ETAI L APPROVED BY: R. ENGLISH E R - 9 02 TEMPORARY SEDIMENT TRAP FOR CATCH BASINS CITY OF EDMONDS STD PLAN ER-902 NTS BMP: SAWCUTTING AND SURFACING POLLUTION PREVENTION (REFERENCE 2005 WASHINGTON STATE DOE STORMWATER MANUAL) PURPOSE: SAWCUTTING AND SURFACING OPERATIONS GENERATE SLURRY AND PROCESS WATER THAT CONTAINS FINE PARTICLES AND HIGH pH (CONCRETE CUTTING), BOTH OF WHICH CAN VIOLATE WATER QUALITY STANDARDS IN THE RECEIVING WATER. THIS BMP IS INTENDED TO MINIMIZE AND ELIMINATE CONCRETE PROCESS WATER AND SLURRY FROM ENTERING WATERS OF THE STATE. DESIGN: VACUUM SLURRY AND CUTTINGS DURING CUTTING AND SURFACING OPERATIONS. DO NOT LEAVE SLURRY AND CUTTINGS ON PERMANENT CONCRETE OR ASPHALT PAVEMENT OVERNIGHT. DO NOT DRAIN SLURRY AND CUTTINGS TO ANY NATURAL OR CONSTRUCTED DRAINAGE CONVEYANCES. DISPOSE OF COLLECTED SLURRY AND CUTTINGS IN A MANNER THAT DOES NOT VIOLATE GROUNDWATER OR SURFACE WATER QUALITY STANDARDS. DO NOT DRAIN PROCESS WATER THAT IS GENERATED DURING HYDRO -DEMOLITION, SURFACE ROUGHENING, OR SIMILAR OPERATIONS TO ANY NATURAL OR CONSTRUCTED DRAINAGE CONVEYANCE. DISPOSE OF PROCESS WATER IN A MANNER THAT DOES NOT VIOLATE GROUNDWATER OR SURFACE WATER QUALITY STANDARDS. HANDLE AND DISPOSE OF CLEANING WASTE MATERIAL AND DEMOLITION DEBRIS IN A MANNER THAT DOES NOT CAUSE CONTAMINATION OF WATER. IF THE AREA IS SWEPT WITH A PICK-UP SWEEPER, HAUL THE MATERIAL OUT OF THE AREA TO AN APPROPRIATE DISPOSAL SITE. Know what's below. Call before you dig. APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION w Q 0 z z O a U U) w 0 d Ln N E W + p U�Mc u rn LL �0" O U) 0) ++ ,,Qo W V) 3 Q c moon o O o o .. � o�:� N � O �` O rn ro = W U Ln _j a m 0 Z z zZ a -w U a z X w LL O � w >� �t W z 2a o- J E- s~ Zy ¢ J m � fn z• �z< ■--� � w LL W O Nw z- Uz co A w� J w J■ Q < D Z U 5;- �--i � U U ~ w LO a �� � a U O M Qo O .I W� a� C �n z J ti Q J Q z W "' 6 U W W z U O l O o U W m U Y W = U o O U TW V 1 Q W N U_m O Z � � � J � G ,p oc�43645 G` R. � 1 STER� � �SSZONAL EC 5/I I/2021 JOB NUMBER 16.00089 SHEET 3 OF 5 C2.1 PORTION OF SECTION 25, TOWNSHIP 27 S., RANGE 03 W■, W.M. / / / / 15ACCESS EASEMENT � /000�/ \\ / \ 30" DEC. � \ \ \ \ o ♦ i \ \ \ � PERVIOUS CONCRETE o`oo' t � UTILITY AND SEWER \ \ \ \ \ DRIVEWAY PAVEMENT \� N�4��� ' 4" SDCO EASEMENT \ \ \ 293 W/ CHECK DAMS RIM TO GRADE 8.25"0 DRY WELL \ \ ♦ SEE DETAILS 1/C3.1 & 6/C3.1 /' IE 289.09 \ \ \ \ TEMPORARY PROJECT BENCHMARK 6 DEEP \ L FOUND REBAR &CAP LS #9891 YDCB FINISHED GRADE 292.40 \ \ \ �/ �♦ TOP OF GRAVEL 290.28 i RIM 292.12 \ \ \ ELEV 287.43 IE 288.62 (IN) \ \ \ \ CONTRACTOR SHALL VERIFY / � � � / � � � \ U IE 288.66 \ \ EXACT LOCATION AND ELEVATION i \ / 8.5' TILITY / BTM OF GRAVEL 283.96 EASE NT \ \ SEE DETAIL 2/C3.1 289.69 / 1 1 290.86 4"SDCO \ ► // \ \ \\ \ \ 289.93 IE 2895 RIM TO GRADE 291.20 / � / IE 288.80 > ' \s Ds CONNECT TO ROOF 291.06 291.27 DOWNSPOUTS (TYP) °�° \ -10.9 1 1 1 1 1 O \ \\ a \ \/ a \\ s �. ' 291.04 1 1 1 1 1 1 1 1 NEW RESIDENCE\o\ 2� \ \ ` \ \� 1 1 1�1 1 11 1 1 ROOF AREA: 2,140 SF FF \ \ CONNECT FOOTING 291.08 291.29 DRAINSSYSTETO STORM 291 29 D G \ - . EX SIDE SEWE� @MAIN / \ \ \ 290 79 1 y 1 1 1 1 1 1 1 1 1 WATER SERVICE POC > I -gam 1\ IE 279.5 \ \ \ 1�1 1 1 1 1 rq1 1 1 �1�1 1 1 4" ROOF DRAIN TIGHTLINE CO RIMTOGRADE 7 1 1 1 @ 1.0% MIN i 1 IE 288.86 S ��� 1 1 P \ \ \ a 1 1 1 O SIDE SEWER POC , / / IE 26 CONNECT TO EX WATER SERVICE STUB ?9 CHECK 1 1 1 1 \ •' IE 290.98 / 0 6 / \ \ , \ `Q\ ♦ ��`�1 \ Ds ° � � /� � / / / \ PER PIC VIEW WATER AND SEWER DAMS DISTRICT SUKVtY UA I UIVI /ERTICAL DATUM: 3ENCHMARK: !" BRASS DISK IN CASED CONCRETE MONUMENT IN CENTERLINE OF 100TI AVENUE WEST 600' NORTH OF INTERSECTION WITH SR 104/EDMONDS WA' )PPOSITE THE SOUTHEAST CORNER OF CEMETERY PROPERTY. 1EVATION = 312.10 FEET. (WGS CONTROL POINT #22) HORIZONTAL BASIS OF BEARING: J74°00'00"E BETWEEN FOUND MONUMENTS ON 15TH STREET SW. :QUIPMENT USED: VSTRUMENTATION FOR THIS SURVEY WAS A 5 SECOND THEODOLITE ANC kN ELECTRONIC DISTANCE MEASURING UNIT. PROCEDURES USED IN THI,1 )URVEY WERE FIELD TRAVERSE, MEETING OR EXCEEDING STANDARDS :FT RY M/0r qq9-1 qn-nQn @ 2.0% MIN POWER/TELEPHONE/CABLE POC\ NEW GAS METER & SERVICE LINE SERVICE LINE TO MAINTAIN 18" COVER MIN. PROVIDE 12" MIN. SEPARATION AT ALL GAS/SD CROSSINGS CNJCIVICIV 1 / \ ' "'"' ' - "' " CONNECT T6 EX \ IE 289.5 \ \ \ GAS MAIN \ \ - - 7 \ EX SSCO \\ \ \ ` \ IE 283.53 a \ 0 \ \ \ \ \ EX SSCO ZE 283.25 \ \\\ \ \\ \\ \ \ \ / \V` TEMPORARY PROJECT BENCHMARK FOUND REBAR & CAP LS #9891 ELEV 289.73 CONTRACTOR SHALL VERIFY EXACT LOCATION AND ELEVATION UtziNtKAL INU I t5 CITY OF EDMONDS WILL TV SEWER LINE PRIOR TO FINAL ACCEPTANCE. ALL SEWER PIPE SHALL BE SDR 35 OR BETTER PER ECDC 18.05 ALL UTILITY SERVICES SHALL BE INSTALLED UNDERGROUND. PLACE CABLE/TEL/TV LINE IN POWER LINE TRENCH. CONDITION OF EXISTING LATERAL SHALL BE VERIFIED BY THE CITY OF EDMONDS. CONTACT THE SEWER DIVISION AT 425-771-0235. IF NEW LATERAL IS REQUIRED, A MANHOLE WILL BE INSTALLED AT THE CONNECTION TO THE MAIN UNLESS SEWER DIVISION n1 TGRAAIKIGC ()TI-IGRV /ICG UTILITY NOTE: THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ITS REPRESENTATIVE. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES THAT HAPPEN DUE TO THE CONTRACTOR'S FAILURE TO LOCATE EXACTLY AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES. BEYLER CONSULTING ASSUMES NO LIABILITY FOR THE LOCATION OF UNDERGROUND UTILITIES. • a e Know what's below. Cali before you dig. 10 5 0 10 SCALE: 1" = 10' APPROVED FOR CONSTRUCTION OLYMPIC VIEW WATER AND SEWER DISTRI z 0 cy- U V) w 0 d Ln N Ucc:,. O IL�"to ON, O1 LLIna,4 O 4.1aC W (n�� 3 O�ON O O�o.. o0� N %' O OrnM-c a) U 1n-i n m 0 M � Q O O z J o WLn � ' z CL Q �- Q CL z W Q > c U C� z Q OO ca gzz LU V W Q z W 0 U p 1►� W ILL 0 co Z U 0 CL J Tel 5/11/2021 30B NUMBER 16.00089 SHEET 4 OF 5 C3. 0 PORTION OF SECTION 25, TOWNSHIP 27 S., RANGE 03 W., W.M. w z w RESIDENCE a 0 Of CLEANOUT WITH 45' BEND AND 2' CAP - CLEANOUT (MAX) (TYP) TO EXCEED 100' BETWEEN CLEANOUTS CLEANOUT (WYE WITH CAP AND CLEANOUT COVER) AND CONCRETE LEVELING COLLAR 2" t r FINISHED GRADE z a Of w n F w z Law a 0 c a 3 a 0 , 4" (MIN) 000000 000000� 6" (MIN) O O 6" (MIN) 65 1' (MIN) ABOVE SEASONAL HIGH GROUNDWATER TABLE OR HYDRAULICALLY /yj RESTRICTIVE LAYER = PERVIOUS CONCRETE, SEE NOTE 1 PERMEABLE BALLAST, } SEE NOTES 2 & 3 RUNOFF TREATMENT LAYER (IF REQUIRED PER EDMONDS STORMWATER CODE), SEE NOTE 4 SUBGRADE, SEE NOTE 5 GENERAL NOTES: 1. REFER TO THE 2017 CITY OF EDMONDS STORMWATER ADDENDUM FOR SETBACK (CHECKLIST 11) AND INFEASIBILITY REQUIREMENTS. 2. THE MINIMUM THICKNESS SHOWN ABOVE MAY NOT BE SUFFICIENT FOR ALL APPLICATIONS. A PROJECT SPECIFIC PAVEMENT DESIGN SHALL BE PREPARED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON IN CIVIL ENGINEERING TO: 2.1. SUPPORT THE ANTICIPATED LOADING (E.G. PAVEMENT DESIGN LIFE, INITIAL AND TERMINAL SERVICEABILITY, RELIABILITY, ETC.) AND 2.2. TO SATISFY THE HYDROLOGIC REQUIREMENTS OF THE CITY OF EDMONDS STORMWATER CODE (I.E., CODE MAY WARRANT A THICKER PAVEMENT SECTION THAN THE MINIMUM STRUCTURAL SECTION REQUIRED). 3. FOR SUBGRADE SLOPES 3% OR GREATER, SUBSURFACE CHECK DAMS OR OTHER METHODS TO PROMOTE SUBSURFACE PONDING ARE REQUIRED. 4. GEOTEXTILE SHALL NOT BE USED IN PAVEMENT SECTION UNLESS REQUIRED BY GEOTECHNICAL ENGINEER. IF REQUIRED, GEOTEXTILE SHALL CONFORM TO WSDOT 9.33.2(1) GEOTEXTILE FOR SEPARATION, WOVEN TYPE. 5. REFER TO WSDOT LOCAL AGENCY GSPs DIVISIONS 2-9 FOR APWA GSPs. NOTES: 1. PERVIOUS CONCRETE SHALL CONFORM TO REQUIREMENTS OF APWA GSP 5-06SA. SURFACE SLOPE SHALL BE BETWEEN 0.5% AND 10%. 2. PERMEABLE BALLAST SHALL CONFORM TO THE REQUIREMENTS OF APWA GSP 4-04.2(9-03.9(2)).OPT1. 3. PAVEMENT BASE SHALL BE INSTALLED PER APWA GSP 4-04.3(5) SHAPING AND COMPACTION. 4. RUNOFF TREATMENT LAYER SHALL MEET THE REQUIREMENTS OF 2017 CITY OF EDMONDS STORMWATER ADDENDUM. 5. PREPARE AND PROTECT SUBGRADE PER APWA GSP 2-06.3(3) SUBGRADE FOR PERMEABLE PAVEMENTS. 4,s. t. 18L3v 12" LOCKING COVER SEE NOTE 3 END OF PIPER GRIPPER PLUG (CHERNE 27061 OR APPROVED EQUAL) '--WATER TIGHT CAP RISER LEVELING COLLAR7- ;m\vA�1\yxwl� 45' SEE NOTE 4 45' 12" PVC SLEEVE 6" RISER 4" OR 6" SIDE SEWER 6" WYE AND 6" CITY STUB GENERAL CLEANOUT DETAIL 45' BEND 4" OR 6" 12" LOCKING COVER SIDE SEWER CLEANOUT DETAIL z SEE NOTE 3 AT PROPERTY LINE/CITY EASEMENT F w LEVELING COLLAR NOTES: j o w SEE NOTE 4 c� ASPHALT SURFACE 1. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE GASKETED. �i 12" f 2. PIPE SLOPE TO BE 2% MIN AND UP TO 50% MAX. 3. SEWER CLEANOUT COVER TO BE EAST JORDAN IRON WORKS 1 FOOT LONG 12" PVC PRODUCT #00366102 STAR PIPE COSP48L OR APPROVED SLEEVE EQUAL. 6" RISER END OF PIPE GRIPPER 4. LEVELING COLLAR SHALL BE CONSTRUCTED AS FOLLOWS: PLUG (CHERNE 270261 OR APPROVED EQUAL) • IN ROADWAYS PER COE STD DWG GU-424 TYPICAL CLEANOUT • IN SIDEWALK/LANDSCAPED AREAS, EITHER 24"x24"x6" UNDER ASPHALT OR CONCRETE DEEP CONCRETE COLLAR OR 24" DIAMETER x 6" DEEP CONCRETE COLLAR `St. 18yv REVISION DATE CITY OF EDMONDS JANUARY 2018 SEWER CLEANOUT DETAILS PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S S- 2 0 0 SEWER CLEANOUT DETAILS CITY OF EDMONDS STD PLAN SS-200 NTS CITY OF EDMONDS PUBLIC WORKS DEPARTMENT TYPICAL PERVIOUS CONCRETE PAVEMENT APPROVED BY: R. ENGLISH TYPICAL PERVIOUS CONCRETE PAVEMENT CITY OF EDMONDS STD PLAN SD-622 wow zw oz � X0 a WQW IL aa0 Qom NOTES: REVISION DATE DECEMBER 2017 STANDARD DETAIL SD-622 NTS OBSERVATION PIPE MARKING TYPE 1 OR 1-L CATCH CENTER OF DRYWELL BASIN W/ SOLID LID PER 48" DIA. (MIN) DRYWELL CITY STANDARD DETAIL SD-303 OR SD-304 4" (MIN) PERFORATED \ PVC UNDERDRAIN PIPE \ \ CLEANOUT w z� 5 \ / J z w (MIN) / Of wN \ �/ a� 0 � (MIN) GUTTER 4" (MIN) PVC DRAIN PIPE (TYP) Fli 5' (MIN) 10, (MIN) PROPERTY LINE/EASEMENT PLAN 1990 NTS REMOVABLE PUSH -ON PVC CAP ROOF DOWNSf 4" (MIN) PVC DRAIN PIPE PER WSDOT SPEC. 9-05.1(5), 1 % (MIN) SLOPE TEST PLUG IN PLASTIC BOX MARKED 'DRAIN" CLEANOUT 12 BUILDING 12" (MIN) 11=III=III -III=111�11 12" MIN 4" (MIN) PVC DRAIN PIPE PER WSDOT SPEC. 9-05.1(5), POSITIVE TOPSOIL= = T= 1= = SLOPE 6" (MIN) (� Ol GENERAL NOTES: 12" (MIN) z ��� 4" (MIN) 1. REFER TO THE 2017 CITY OF z O �00 PERFORATED PVC EDMONDS STORMWATER ADDENDUM REMOVABLE jO UNDERDRAIN FOR SETBACK (CHECKLIST 13) AND PIPE PER WSDOT PvcHr �N INFEASIBILITY REQUIREMENTS. SPEC. 9-05.1(6) 2. MINIMUM COVER DEPTHS ASSUME NO VEHICULAR LOADING. DESIGNER TO GEOTEXTILE, SEE NOTE 1 SPECIFY COVER DEPTHS IF VEHICULAR TRAFFIC ANTICIPATED. WASHED DRAIN ROCK, 7 3. PROVIDE 10 FEET (MIN) SPACING SEE NOTE 2 - BETWEEN DRY WELLS. - NOTES: UNCOMPACTED NATIVE MATERIAL, SCARIFY 3" 1. PLACE GEOTEXTILE FABRIC ALONG WALLS AND TOP OF WASHED (MIN) 1' (MIN) ABOVE SEASONAL ROCK. GEOTEXTILE SHALL CONFORM TO WSDOT SPEC. 9-33.2(1), HIGH GROUNDWATER TABLE_j GEOTEXTILE FOR SEPARATION, NON -WOVEN TYPE. OR HYDRAULICALLY RESTRICTIVE LAYER 2. WASHED DRAIN ROCK SHALL CONFORM TO WSDOT SPEC. 9-03.12(5), GRAVEL BACKFILL FOR DRYWELLS. PROFILE NTS 3. OBSERVATION WELL SHALL CONFORM TO WSDOT SPEC. 9-05.2(6), PERFORATED PVC UNDERDRAIN PIPE. REVISION DATE TYPICAL DOWNSPOUT DECEMBER 2017 CITY OF EDMONDS INFILTRATION DRYWELL PUBLIC WORKS STANDARD DEPARTMENT DETAIL Fs 9� APPROVED BY: R. ENGLISH S D- 6 3 8 `(IF STUB FOR FUTURE DEVELOPMENT) / SEWER STUB SHALL BE LOCATED 10' INSIDE PROPERTY UNE & STAKED. PLACE 2 x 4 AT END OF SIDE SEWER STUB AND CUT TO LENGTH TO ENSURE 3 FEET EXTENDS ABOVE GRADE. PAINT TOP 18 INCHES WHITE. IN 3 INCH HIGH LETTERS, STENCIL THE NUMBER OF EVEN FEET FROM GROUND ELEVATION TO THE SEWER STUB INVERT. 8 GAUGE WIRE TO BE DOUBLE WRAPPED AROUND PIPE AND 2 x 4 STAKE AT OR ABOVE FINISHED GRADE. w z J W a LOCKING CLEANOUT COVER a ` PER COE STD DTL SS-200 6" LATERAL SEWER SLOPE - 2% MIN TO 50% MAX 22.5' OR 45' BEND 6" TEST TEE 6" WYE/6" ROMAC SADDLE SEE NOTES 1 AND 2 POSSIBLE SEWER MAIN LOCATION 22.5' OR 45' BEND 6" TEST TEE 6" TEE POSSIBLE I SEWER MAIN LOCATION 1. WHEN TAPPING INTO EXISTING MAIN A ROMAC STYLE CB SADDLE SHALL BE USED. PLACEMENT OF TEE SHALL DEPEND ON DEPTH OF SEWER MAIN. AS A MINIMUM, THE TEE SHALL BE PLACED AT A 45 DEGREE ANGLE FROM PIPE SPRINGLINE. 2. IF NEW MAIN IS BEING INSTALLED OR MAIN IS BEING REPLACED, SERVICE CONNECTION TO THE MAIN SHALL BE DONE WITH A WYE. WYE SHALL BE AT A 45 DEGREE ANGLE FROM PIPE SPRINGLINE. 3. IF CONNECTING EXISTING PRIVATE SIDE SEWER TO NEW CITY LATERAL, A CONCRETE/PVC STRONGBACK FERNCO RC SERIES OR ROMAC COUPLING SHALL BE USED AND SECURED PER MFR'S INSTRUCTIONS. 4. BORING OF SERVICES WITHIN RIGHT OF WAY IS NOT ALLOWED. 5. SEWER PIPE SHALL BE SDR-35 AND JOINTS SHALL BE GASKETED. 6. IF STUB FOR FUTURE DEVELOPMENT, USE RUBBER JOINT BISCUIT PLUG OR OTHER APPROVED WATERTIGHT PLUG. REVISION DATE CITY OF EDMONDS FEBRUARY 2018 NEW LATERAL SEWER T - PUBLIC WORKS STANDARD DEPARTMENT DETAIL FS t . 18 90 APPROVED BY: R. ENGLISH S S - 2 0 2 NEW LATERAL SEWER CITY OF EDMONDS STD PLAN SS-202 DOWNSPOUT INFILTRATION DRYWELL CITY OF EDMONDS STD PLAN SD-638 NTS CONTROL JOINT (TYP) (PERVIOUS DESIGNER TO SPECIFY CONCRETE ONLY) SPACING, SEE NOTE 1 DESIGN WATER SURFACE DESIGNER TO SPECIFY ELEVATION CONTROLLED CHECK DAM HEIGHT BY OUTLET SLOPE PERMEABLE PAVEMENT SECTION, SEE NOTE 2 _ _ 6„ CONTROLLED DENSITY FILL 3" (MIN) KEY SUBSURFACE CHECK DAM PER WSDOT SPEC. 6" (MIN) BED 2-09.3(1)E (TYP) 12" (MIN) CONTROLLED DENSITY FILL CHECK DAM (FOR AREAS OUTSIDE OF PUBLIC RIGHT-OF-WAY AND CITY EASEMENTS) EXTEND LINER AS NEEDED TO SECURE DURING DESIGNER TO SPECIFY CONSTRUCTION SPACING SEE NOTE 1 MECHANICAL PLUG EXTEND CLEANOUT 2" ABOVE DESIGN PONDING ELEVATION OR PER PLAN 4" STREAMBED COBBLES PER WSDOT 9-03.1 1(2) DESIGN PONDING ELEVATION - oa �gC _ Oo�o�G IIIIIIII III=III- -III-III-III-� III-IIIIIIIIIIIII� I -III -III -I 1I- _III-III-III-I II_ „Ill, � �l l lllil l SOIL TIGHT 45' BEND WYE - -_� :IIIIIIII, ASPHALT/ CONCRETE TRAFFIC RATED, IRCULAR LOCKING AST VALVE BOX PER ANUFACTURER ECOMMENDATIONS, EE NOTES 1 AND 2 N \-- MECHANICAL PLUG ADD VALVE BOX EXTENSION OR SOIL PIPE AS NECESSARY TO ACCOMMODATE O.D. OF RISER PIPE CLEANOUT COVER IN PAVED AREA SOIL TIGHT _ LAWN/ NDS PRO SERIES VALVE COUPLER 1-LLI LANDSCAPE BOX WITH LOCKING 6" MIN COVER, OR EQUAL. SEE UNDERDRAIN PIPE, J�Or (MIN) NOTES 1 AND 2. 4" (MIN) 000000 0OoO00 PLUG OR CONTINUED UNDERDRAIN CRUSHED SURFACING MECHANICAL PLUG CONNECTION TOP COURSE (CSTC) CLEANOUT PER WSDOT 9-03.9(3) (SHOWN WITHIN BIORETENTION FACILITY) CLEANOUT COVER IN LANDSCAPE AREA GENERAL NOTES: 1. CLEANOUT PIPE SHALL BE SAME SIZE AND MATERIAL AS UNDERDRAIN PIPE. 2. CLEANOUT SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES. 3. ALL FITTINGS SHALL BE SOIL TIGHT. 4. CLEANOUT RISER TOP SHALL BE LOCATED OUTSIDE OF PONDING AREAS WHERE POSSIBLE. NOTES: 1. CLEANOUT COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED "DRAIN CLEANOUT," "CLEANOUT," "CO," OR SIMILAR. 2. TRAFFIC RATED LID REQUIRED IN AREAS WITH VEHICULAR LOADING. `s+t. 18L3v REVISION DATE CITY OF EDMONDS STORM DRAINAGE DECEMBER 2017 CLEANOUT PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S D - 61 9 STORM DRAINAGE CLEANOUT CITY OF EDMONDS STD PLAN SD-619 2" (MIN) CHECK DAM CLEARANCE, I DESIGNER TO SPECIFY 12" (MIN) COVER CHECA CHECA CHECA CHECA (4) CH 1 , ' (3) CH SLOTTED PVC DING UNDERDRAIN PIPE WITH SUBSURFACE CONTROL STRUCTURE PER STD DETAIL SD-628, SEE NOTE 3 2" (MIN) CHECK DAM CLEARANCE, DESIGN WATER DESIGNER TO SPECIFY SURFACE ELEVATION SLOPE 12" (MIN) COVER PERMEABLE PAVEMENT SECTION, SEE NOTE 2 = 3" (MIN) KEYmor �co_ s I� 30 MIL LINER �� T�i I� _I (TYP), SEE NOTE 4ESIGNER TO 12" (MIN) SPECIFY CHECK DAM HEIGHTLOTTED PVC IMPERMEABLE LINER CHECK DAM NDERDRAIN PIPE 6" MIN BEDTH SUBSURFACE (MIN) CONTROL STRUCTURE PER STD DETAIL NOTES: SD-628, SEE NOTE 3 1. DESIGNER SHALL DETERMINE AND SPECIFY SUBSURFACE CHECK DAM SPACING BASED ON THE SUBGRADE SLOPE AND DESIGN AVERAGE STORAGE DEPTH REQUIRED. TYPICAL MAXIMUM SPACING CAN BE ESTIMATED BY DIVIDING THE CHECK DAM HEIGHT BY THE SUBSURFACE SLOPE. 2. SEE STD DETAIL SD-621 THROUGH SD-624 FOR PERMEABLE PAVEMENT SECTION. 3. IF REQUIRED, UNDERDRAIN PIPE SHALL BE 6" MINIMUM DIAMETER (PRIVATE), 8" MINIMUM DIAMETER (PUBLIC). SLOPE PIPE AT 0.5% MIN UNLESS OTHERWISE SPECIFIED. PROVIDE ONE CLEANOUT (MIN) PER 100 FEET OF UNDERDRAIN, AND AT EACH END. LOCATE UNDERDRAIN BELOW STRUCTURAL PAVEMENT BASE DEPTH. 4. LINER SHALL BE HDPE CONFORMING TO GEOSYNTHETIC RESEARCH INSTITUTE (GRI) GM13 OR LLDPE CONFORMING TO GRI GM17. `St. 18,3- REVISION DATE CITY OF EDMONDS PERMEABLE PAVEMENT DECEMBER 2017 SUBSURFACE PUBLIC WORKS CHECK DAMS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH S D- 6 2 7 PERMEABLE PAVEMENT CHECK DAMS NTS 6 NTS DAM HEIGHT = 4" DAM CLEARANCE = 2" DAM SPACING (OC) = 4' (NORTH SECTION) DAM SPACING (OC) = 6.5' (SOUTH SECTION) ECK DAMS REQUIRED (NORTH SECTION) ECK DAMS REQUIRED (SOUTH SECTION) NTS APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION w Q 0 Z d N E U U) m rn 1L N G1 0 U) ++ �a00 W U)Z,M 3 Ix O -6N O O�0 o.. �03C ai N O OMra- O U in _j a z 0 M z ti O OW Q � J o� �- o ' z Q CL z Lu c) Lu > C� W a z Z o u_ ~ O U � O}0 �I W cl000 O z O =� U � ILL o m Z U 0 J 5/II/2o21 JOB NUMBER 16.00089 SHEET 5 OF 5 C3.1