Loading...
APPROVED ENG BLD2023-0380+DEMO Site_Plan+3.28.2023_3.55.41_PM+3449220I I EX HOUSE I / w n * sr -9 I � \I I I TREE RETENTION/MI TIGA TION AREA I I 7 8,519 SF - -1 (CROSS -HATCHED AREA) F -1 I 4 INSTALL 3' X 3' DRYWELL EX / WITH3/4-TO 1-1/2"DRAIN I BLDG ROCK FOR WALL DRAIN CONNECTION (3' M/N DEPTH) PLAT OF AURORA HEIGHTS DIVISION NO, 3 I BLOCK 9 Ex BLDG EX BLD)� I TOP 432.0 3 TOE 429.0_ 432 EX SHED BnE /J 3 TOP 433.0 IL�ISLT/ ��� TOE 430.0 � 75 1 I ��75 2 WALL, A SOCIATED DRAINA E AND CONSTR JCTION ACTIVITIES SHALL NOT ENCROACIH ONTO ADJACENT PROPERTY TO WEST. NO TE.• ALL ONSITE IMPROVEMENTS TO BE REMOVED UNLESS OTHERWISE NOTED _ I FILTER FABRIC I FENCE (TYP) EX SHED TO BE i REMO VED 1 I � I 760 I �e H \ EXISTING TREES �� TO REMAIN (TYP) 2 TOP 433.0 1 - i CONC BLOCK WALL , XlSTING-fii4E (3 MAX HGT) TO BE REM E, SEE DETAIL THIS SHT - -� - - // � EX) HOUSE EXISTING SEWER I TO►' BE I REMOVED SERVICE TO BE � / I �- - REMOVED I / I SEWER TOLE CUT AND CAPPED AT PROPE Tim - 25 ,I ; ` �- LINE 3 TOE 29.5 76�E � dl I I 777 I 7 6 I I I 36 EX HOUSE I i I �� 1 I 4 I I� 1 I I 75 I /� 7 I I\ AS ROW BEOIND SIDE VALK IS 05 TOP 432.5 �7I III TOE 432.0 d I / I / �� 17 \ I I REGRADED, CONFIRM POLE I I +4 / X = I - I j 76 IE F r E_ TREE PROTECTION FENCING AS REQUIRED. CONTRACTOR SHALL 761 l Z J CONC BLOCK WALL (3' MAX HG T�� F - TO I 438.5 5 TO 436.0 CLEARING I`�\ (TYP) EX HOUSE 765 ANY WORK DONE WITHIN THE DRIPLINE I OF TREES TO BE SA VED WILL NEED TO BE EVALUATED BY ARBORIST I I TOP 438.0 � TOE 436.0 2 I EXISTING SPLIT RAIL FENCE TO BE REMOVED NW 1 /4, SEC 30, TWP 27N, RGE 4E, W.M. PLAT OF AURORA HEIGHTS DIVISION NO. 3 BLOCK 1 \ 1 i �I E ISTING SHED T01 BE REMOVED - READ THE TREE PROTECTION NOTES (ON SHEET GN-01) AND / PROJECT ARBORIST REPORT LETTER (BY CREATIVE LANDSCAPE / SOLUTIONS) PRIOR TO CONSTRUCTION. THE PROJECT ARBORIST SHALL BE CONSULTED AND SUPERVISE ALL WORK WITHIN THE CRITICAL ROOT ZONE/CANOPY OF ANY TREE TO BE RETAINED. / FlL TER FABRIC �� FENCE (TYP) DEPTH OF BURY IS / 4&X ASPHALT I 7 CONSTRUCT STABILIZED I ACCEPTAB� E TO PUI� EXISTING POWER I I QRIVEWAY TO I TEMPORARY CONSTRUCTION I POLE T REMAIN / 7� REMOVED I ENTRANCE AT EXISTING i III DRI VEWA Y - _ EXISTING WATER METER TO BE REMOVED. - •� i EX RETAINING WALL &FENCE ALONG (EXISTING WATER METER SHALL BE - -1T STREET FRONTAGE TO BE REMOVED RETAINED UNTIL NEW METER IS INSTALLED. / - T1 1.6 < HOSE SPIGOT & AVB SHALL BE INSTALLED III / I I =434 - - �. _ / TOP 436.5 FOR USE DURING CONSTRUCTION.) I II I I -' �-"- '- 1?- P TOE 434.0 'S I 4,31 �_ 69 CB RIM=438.11 \ � I \ IE 12" CPP(W�428.86 IE 12" CPP(E)=428.86 I SSCO R/M=42�4�J`! _ _ � I i \ 1 ---------- --�� ` --------------- ----1------- ----/ ---- - ---- -- --__-- -- i ------ ` __ _-� ���i7 =�==SD�-3i--S6=-_ - -1 _ � --- -- - --_--- ------1 'rJ i x o -- -- --- - \��----------------\\�' SJS---SIF=----56----SU----56---- `\-'- -- - --- - - -- r� r-- ----r----- J ry' W/2 BRASS DISK PUN DOVV 1.4'. VISITED 9-2-Cry H. ---W I N --W- I I I - / III -�- - i - ---- ---- ----W�__ II �� �ry ; �� ACO D` -- � D` 1 / I\-�- --G----G----G=---G-�a----G +--G-----I G--- ,--- 12+DO - ---SS---SS---ASS----� SS�� SSMH RIM=426.i46 --SS----SS---- - -- I --- -SS- ---SS��---- - _--- �I PROPOi D CB \ PROTECIITION (TYP) \ SS- ---S�6----SS----SS- 28THry I --z---------- c � I I --- / ------- i ----_ �\\\\ III � r // 7---------------- r-- -/ -- ---- I \ t /► 1--- ------- ----7 CB R1M=429.44 u I I I CB RIM=429.45 IE 12" CPP(W)=426.11 T__ I -. IE 12 CPP(N)=426.18 IE 12" CPP(E)=426.11 I IE 12" CPP(S)=426.14 I I l p I I N SCALE.• 1 " = 20' 0 10 20 40 TREE LEGEND TREE TAG NUMBER (SEE TREE RETENTION PLAN FOR DESCRIPTION) k,// Xxx xxx EXISTING TREE TO BE REMOVED xxx xxx DRIP LINE EXISTING TREE TO REMAIN I I -TREE PROTECTION FENCING (LIMITS OF DISTURBANCE) CONSTRUCTION SEQUENCE 1. SCHEDULE A PRE -CONSTRUCTION MEETING WITH CITY ENGINEERING DIVISION AT ENGINEER/NGPERMITS@EDMONDSWA.GOV. TWO DAY (48 HR) NOTICE IS REQUIRED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. J. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HA VE EROSION CONTROL MEASURES INSPECTED BY Cl TY OF EDMONDS Cl TY ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION /S ESTABLISHED. 6. DEMOLISH EXISTING STRUCTURES 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 8. CLEAR, GRUB & ROUGH GRADE SITE. REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. (OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW) 9. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SITE. 11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. UNDISTURBED PLANTS UNDISTURBED TURF (LAWN) (SEE NOTE 1) AREAS (SEE NOTE 1) UNDISTURBED UNDISTURBED NATIVE VEGETATION ' 0" TURF/LAWN/LANDSCAPE UNDISTURBED NATIVE SOIL \y/\\/\ \ \ / UNDISTURBED NATIVE SOIL STEEP SLOPE NOTE: 1X'/���� AMENDED SOILS SHOULD NOT BE INSTALLED ON FINISHED SLOPES OPTION 1 - NO DISTURBANCE EXCEEDING 33%. AREAS EXCEEDING 33% SHALL BE STABILIZED PER THE PLANTING BEDS TURF (LAWN) AREAS ENGINEER/GEOTECH OF RECORD. SEED OR SOD 2" ORGANIC MULCH 3" OF COMPOST - --I'�'�"�1 I I I - IE=111=III I-TI��IIIII=III-IIIII 1.75" OF COMPOST INCORPORATED INCORPORATED INTO 5" OF II_ I I I I II 11=1 I I I f=1 I Il _ I I-IIII I I_I INTSITEIL (FORA SITE 501E (TOTAL AMENDED I __1 =III 11=�=111��)�--�I�--III�I I AMENDED DEPTH 0F 905", A DEPTH of 9.5", FORA I�I I1-III-III Ir11I= �FII�I� -III-III-III=11 SETTLED DEPTH OF 8") DEPTH OF 8") I I f=i=SETTLED MIXI FI I I -III -III I F 1� I I-111=III-I I II II-III�II=IIFI�ILI II-Ili-IIFIIFIIFIFII I H I FIFI I FI I F I 1 g" -1 i FI I FI a-1 1 1=111=1 I SUBSOIL SCARIFIED 4" BELOW ". ' \\ / SUBSOIL SCARIFIED 4" BELOW COMPOST AMENDED LAYER COMPOST AMENDED LAYER (12" BELOW SOIL SURFACE) / / /; . f (12" BELOW SOIL SURFACE) I OPTION 2 - AMEND IN PLACE OR STOCKPILE AND AMEND GENERAL NOTES: PLANTING BEDS TURF (LAWN) AREAS 1. AREAS OF NO DISTURBANCE ., SHALL BE FENCED AND EXISTING 2" ORGANIC j�� j�� j� GRASS: SEED VEGETATION AND SOIL SHALL BE MULCH ,���/,�� 0" I OR SOD PROTECTED FROM CONSTRUCTION I I=1 I I=1 I I�IFI! fah =III- - 1- 1 I I-1 I rIT1=1 I FTFTi-111 IMPACTS. I H I H I I l-I 11=1 11-1 11=I I I=111� I I� I� I 6" IMPORTED I�II�I€=IIFIII-II I I F I FI 11=T1=1 11=1 11=1 I I E I I I -I I I=11 F1 I F11 I FI I I=III FIIF111=1I1=III=III=III 6" IMPORTED 2. TO MEASURE SETTLED DEPTH, WATER SOIL SUFFICIENTLY TO TOPSOIL MIX 11=III=11HIr�IF-�I I EziI1�1II=111=1IEEII1=1 TOPSOIL MIX FULLY SATURATE WITHOUT I I I I 1=1 I I -I 11=1 (COMPACTED I11=III=111=11HIi-1II� I 1=1 I I=1 11=1 I F1 I F111=111 III=III=III=III-III-III-III (COMPACTED CAUSING EROSION. DEPTH) III 111=III lil 111=11 I II€=11llll Ill III III 6 III DEPTH) 111 II Ili III III=ILI=1 I[ - I+I III-111 III=11! III I' 3. COMPOST SHALL MEET SPEC. =I � I- ij I � I ! REQUIREMENTS IN THE 2017 SUBSOIL IS // \ j % `// I' E / /� I \//\�: SUBSOIL IS EDMONDS STORMWATER ADDENDUM (CHECKLIST 7), SCARIFIED 6" ;\ I' \ J /. _ SCARIFIED 6" f// BELOW . \ IMPORTED \ //\\� \/ \fie - //:" BELOW IMPORTED 4. COMPACTION OF TOPSOIL (WHERE TOPSOIL MIX \ /\//\%"°"�/` /\� \�v // `/ /\!7"' j 12" \% \/i\ TOP50EL MIX REQUIRED) TO BE TO 85% (MAX) OF THE MAXIMUM DRY DENSITY OPTION 3 - IMPORT TOPSOIL PER MODIFIED PROCTOR TEST (ASTM D1557). REVISION DATE POST CONSTRUCTION SOIL APRIL 2021 . CITY OF EDMONDS QUALITY AND DEPTH PUBLIC WORKS STANDARD DEPARTMENT DETAIL "St, 1g911 S D - 642 APPROVED BY: R. ENGLISH APPROVED BY PLANNING iZ Apr 07 2023 GRADING QUANTITIES CUT FILL 1600 CY f600 CY TESC NOTE INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO APPROVED PLANS, EDMONDS STANDARD DETAILS, AND THE SWPPP. CONTRACTOR /S RESPONSIBLE FOR MAINTENANCE AND ADJUSTMENTS TO TESC MEASURES AS NEEDED. CB INLET PROTECT/ON NOTE CATCH BASIN INLET PROTECTION SHALL BE INSERTED AND MAINTAINED ON ALL EX/STING CATCH BASINS W/ THIN 500 FEET OF THE SITE AND ON ALL NEWLY CONSTRUCTED CATCH BASINS THROUGHOUT THE S/TE IMMEDIATELY AFTER INS TALLA T/ON. FILTER FABRIC FENCE NOTE ADD/TONAL FLIER FABRIC FENCING SHALL BE ADDED AS NEEDED. FENCING TO BE INSTALLED PER CITY OF EDMONDS STD DETAIL ER-900 (SEE DETAIL ON SHEET TD-01). STOCKPILE NOTE STOCKPILE SHALL TO STABILIZED BY PLASTIC COVERING. THE EXPOSED SOILS SHALL BE STABILIZED ACCORDING TO AN APPROVED TIMETABLE. (TYPICALLY, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN TWO DAYS FROM OCTOBER 1 THROUGH APRIL 30 AND NO MORE THAN SEVEN DA YS FROM MAY 1 THROUGH SEP TEMBER 30). SOILS NOTE ILL DISTURBED SOILS WILL BE COMPOST AMENDED PER 'ITY STANDARD DETAIL SO-642. SEE DETAIL THIS SHEET. SIDEWALK NOTE THE SIDEWALK ALONG 2207HST SW PROPERTY FRONTAGE SHALL REMAIN OPEN EXCEPT AS NEEDED TO PERFORM SPECIFIC ACT/V/T/ES SUCH AS SIDEWALK REPLACEMENT AND UT/LI TY CONNECTIONS. 12" Min. -.0 Wall Blocky Unit Drainage Fill (18" Min. Depth) o•o 0 1"Clean / .6. . Crushed Rock (No Fines) H = 4' Max. Wall Battery •o•oD Structural Fill / 1 H : 12V �-o' : (Geotechnical / (or Flatter) o; Engineer Q 1 Loads and Structures to to Confirm) / 1 Maintain Min. 1 H:1 V Setback . •o r _ o 0Qo III=III $,.Min. •�••o;o�. a•oQ: / 4" Diameter Perforated PVC 2"_4" ,o,�Q, o,�o.o, o• p, Drain Pipe (By Others) III= R Connect to Approved Discharge Leveling Pad \ (Crushed Rock) Competent Subgrade (Geotechnical Engineer to Confirm) Not - To - Scale City Of Edmonds Building Department Work Address Owner DEMO SFR AND SHEDS 8929 220TH ST SW SELECT HOMES ------------------------- Approved Date Building Official Permit Number BLD2023-0380 - T. nF W � 53803 _IST L ���\�� NA 11 /07/2022 i Know what's below. Call before you dig, Earth arch Solutions Solutions NW LLe Geotechnical Engineering, Com g and Environme C • i- Drwn. MRS Date 11/07/2022 Proj. No. 7515.02 Checked HTW Date Nov. 2022 Plate BW 1 BLD2023-0380 PLN2 021-0038 APPROVED FOR CONSTRUCT/ON CITY OF EDMONDS DATE: 04/05/2023 BY CITY ENGINEERING DIVISION ENGINEERING, INC. Civil Engineering / Land Planning RAM 19109 36TH AVE W, SUITE 100 LYNNWOOD, WA 98036 PHONE: (425) 678-6960 WWW.RAMENGINEERINGINC.COM m � � o_ o Z Lij U U U U o N � rn cN O V y Q �O O Z 00 M 0 N Z v H ZN J m Q W � Q � Q O N � N W O � RECEIVED O Mar 28 2023 LU O CITY M EDMONDS TSERM DEVELOPMENT SERVICES DEPARTMENT 0 WA41 F S 0 / Z 36508 CL% ISTER�� � 'IONTA1. ENGINEER: ROB L. LONG, PE DRAWN BY.• MIKE MORRIS ISSUE DATE. SCALE.• 5123/22 AS NOTED JOB NO. 20-016 SHEET.• TP-0 1 SHT 4 OF 10