Loading...
APPROVED ENG BLD PLN-RESUB1 BLD2023-0182+SITE & Architectural_Plan+3.21.2023_6.29.24_PM+3435108N SCALE DATE: SITE PLAN 1 Address: 9825 240th Pl SW Edmonds, WA 98020 Tax Account/Parcel No: 00-4466-000-002-00 Property Description: FIR MEADOWS NO 4 BLK 000 D-00 - LOT 2 TGW S1/2 VAC 240TH ST SW ABTG PER ORD89-173 AF 9004100500 Lot size: .22 acres (9,450 SF) Existing house: 1331 sf Attached garage: 322 sf Addition: 300 sf TOTAL: 1953 sf Zone: RS-8 MIN. SIDE YARD SETBACK: 7.5' MIN. REAR YARD SETBACK: 15' MAX LOT COVERAGE: 35% (3,307 sf) ACTUAL LOT COVERAGE: 1953/9450 SF = 21% OWNERS: COLIN AND MARIKO BLESSING 541-554-3271 AND 541-556-6382 BUILDING CODE: 2018 International Residential Code as amended by the State of Washington 70'-0" 13 5 ' - 0 " 7'-5" setback to (N) wall 7'-5" setback to (E) wall Demo existing fence and gate 300 sf addition over existing flat patio. No grading required. Existing house centerline of street 30 ' - 0 " (E) shed 15' rear yard setback (E) driveway 27 ' - 0 " 54'-0" 20 ' - 0 " 15'-0" Water meter 1" = 20' 240th Pl SW (E) walk (E) patio 31 ' - 0 " Overframing over existing roof ENERGY CODE PRESCRIPTIVE PATH REQUIREMENTS COMPONENT MIN. PERFORMANCE VALUE FENESTRATION U-FACTOR MAX 0.30 OPAQUE DOOR U-FACTOR MAX 0.20 TRUSS CEILIGN INSULATION MIN R-49 OR R-38 (FULL DEPTH OVER EXT. WALL) WALL R-21 FLOOR R-30 THE FOLLOWING MIN CRITERIA SHALL APPLY PER SWEC TABLE 402.1.1 FOR NEW HEATED AREAS ENERGY CREDIT REQUIREMENTS 1.5 CREDITS REQUIRED FOR ADDITIONS TO EXISTING BUILDING AREA LESS THAN 500 SF OF HEATED FLOOR AREA ADDITION TO HEATED AREA: 300 SF ENERGY CREDITS SHALL BE PROVIDED FROM WSEC TABLE R406.2 OPTIONS AS FOLLOWS FUEL NORMALIZATION CREDITS SYSTEM NO 1: COMBUSTION HEATING EQUIPMENT MEETING MINIMUM FEDERAL EFFICIENCY STANDARDS FOR THE EQUIPMENT LISTED IN TABLE C403.3.2(4) OR C403.3.2(5) = 0 CREDITS OPTION 3.4 HIGH EFFICIENCY HVAC EQUIPMENT DUCTLESS MINI-SPLIT HEAT PUMP SYSTEM, ZONAL CONTROL, WITH A MINIMUM HSPF OF 10.00 SHALL BE INSTALLED AN DPROVIDE HEATING TO THE LARGEST ZONE = 1.5 CREDITS 2/12/23 Ductless mini split 9825 240th Pl SW Edmonds, WA 98020 Powerline Pole W W W GA S GA S GA S S S S S S S (E) fence SSS HEIGHT CALCULATIONS: DATUM POINT: +100' @ TOP OF SS MANHOLE COVER A = +102' B = +104' C = +98' D = +101' Total = 405 Average Grade = 101.25 Actual = 112' @ existing house 110.5' @ addition Maximum = 126.25 (Average Grade + 25') (E) sewer clean out Property line gas meter sewer manhole A C +98D +101 B +104 A +102 TOTAL NEW OR REPLACED IMPERVIOUS SURFACE = 300 SF TESC NOTES: 1. All disturbed areas to be compost amended per 2014 SWMMWW BMP T.5.13. 2. Install and maintain all TESC measures according to approved plans, City of Edmonds standard details, and all other measures that may be required during construction. City Of Edmonds Building Department Work Address Owner Approved Date Building Official Permit Number ADDITION 9825 240TH ST SW BLESSING 4/6/2023 Kevin Bloomfield REVISIONS REV1 REV2 REV3 REV4 REV5 BLD2023-0182 RESUB Mar 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE APPROVED PLANS MUST BE ON JOB SITE SEPARATE PLUMBING PERMIT REQUIRED FOR THIS PROJECT. ENGINEERING DIVISION APPROVED AS NOTED __________________04/06/2023Jeff WhatmoreApplicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. GUTTERS/DOWNSPOUTS SHALL DRAIN TO SPLASHBLOCKS ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF EDMONDS STANDARD DETAIL SD-642 OR APPROVED EQUAL. Zone __________ Corner ____ Flag ____ Setbacks: Required Actual Front _______ _______ Sides _______ _______ Rear _______ _______ Other _______ _______ Height _______ _______ RS-8 25'31' 25' 7.5'7.5' 15'55' 11' APPROVED BY PLANNING Apr 07 2023 N SCALE DATE: DEMO FLOOR PLAN 21/8" = 1'-0" REMOVE EXISTING DOORS; PREP FRAME FOR INSTALLATION OF NEW DOORS DEMO EXISTING CONCRETE STAIR AND LANDING REMOVE AND SALVAGE EXISTING WINDOW FOR REINSTALLATION IN THE ADDITION. PREP OPENING FOR NEW DOOR. DEMO CASEWORK SEATING BENCH/CABINET. PATCH/REPAIR WALLS, FLOOR, AND KITCHEN CABINETS. FAMILY ROOM KITCHEN NOOK LIVING ROOM GARAGE BEDROOM BEDROOM BEDROOM BATH BATH 27 ' - 0 " 54'-0" 39 ' - 0 " 13'-6" DEMO GARAGE WALL FOR (N) 2'-8"x6'-8" DOOR TO SIDE YARD FIELD VERIFY EXACT LOCATION NEW DOOR (NOT SHOWN ON ENLARGED PLAN). (2) 2x8 HEADER ABOVE 2/12/23 9825 240th Pl SW Edmonds, WA 98020 Existing downspout and splash block Existing downspout and splash block Existing downspout and splash block RESUB Mar 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N NEW FLOOR PLAN 31/4" = 1'-0" SCALE DATE: SW - 6 SW-6 SW-6 SW - 6 ROOF TRUSS @ 24' oc (2)2x8 HDR(2)2x8 HDR (2 ) 2 x 8 H D R (2 ) 2 x 8 H D R (N) full-lite French doors in existing opening. (Doors to swing opposite way from existing condition.) 2' - 4 " x 6 ' - 8 " 6' - 0 " x 6 ' - 8 " s l i d i n g d o o r 5'-0" x 6'-8" sliding door Infill existing opening for new 5'-0" wide door (N) 12" wide steps; max rise 7.5" (N) 12" wide steps; max rise 7.5" 15'-0" 20 ' - 0 " 4'-7" 4' - 1 0 " +/- 20" eave (match existing) KITCHEN (E) FAMILY ROOM / (N) DINING ROOM (N) FAMILY ROOM CLOSET NOOK RIM BOARD REQ'D FACE NAILING TO WOOD BELOW (4) ANCHOR BOLTING TO CONCRETE BELOW (5) SW-6 YES 8d @ 6" oc CLIP @ 24" oc 1 3/4" LSL 16d @ 6" oc 5/8" DIAMETER @ 48" oc 240 PLF SW-4 YES 8d @ 4" oc (2) CLIP @ 20" oc 1 3/4" LSL 16d @ 4 3/4" oc 5/8" DIAMETER @ 48" oc 355 PLF (1) NAILS SHALL BE 8d COMMON NAILING APPLIED TO ALL PANEL EDGES (BLOCK ALL UNSUPPORTED PANEL EDGES), TOP & BOTTOM PLATES AND BLOCKING. NAIL TO INTERMEDIATE FRAMING MEMBERS WITH 8d @ 12" oc (2) FRAMING AT ADJOINING PANEL EDGES SHALL BE 3-INCH NOMINAL OR WIDER AND NAILS SHALL BE STAGGERED (5) PROVIDING 3"x3"x0.229" PLATE WASHER AT ALL ANCHOR BOLTS. ANCHOR BOLTS SHALL BE POSITIONED SUCH THAT PLATE EDGE OF PLATE WASHER IS WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE (PLATE WASHER MAY BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 13/16" AND A LENGTH NOT TO EXCEED 1 3/4") (3) CLIP SHALL BE EITHER A35 OR LTP4 (4) NAILS SHALL BE 10d COMMON; SCREWS SHALL BE SIMPSON SDS25300 BOTTOM PLATE ATTACHMENT SHEAR WALL SCHEDULE SW # BLOCKING ATTACHMENT TO TOP PLATE (3) PANEL EDGE NAILING (1) CAPACITY (PDF) SEISMIC SHEAR WALL SCHEDULE NOTES 1. INSTALL PANELS EITHER HORIZONTLLY OR VERTICALLY FOR ENTIRE LENGTH SHOWN ON PLAN. SHEATHING SHALL BE APPLIED DIRECTLY TO FRAMING. 2. WHERE SHEATHING IS BOTH SIDES OF WALL, PANEL EDGES ON 2X STUDS SHALL BE STAGGERED SO THAT JOINTS ON OPPOSITE SIDES ARE NOT LOCATED ON THE SAME STUDS. 3. BLOCKING IS REQUIRED AT ALL PANEL EDGES. 4. PROVIDE SHEAR ALL SHEATHING AND NAILING FOR THE ENTIRE LENGTH OF THE WALLS INDICATED ON THE PLANS. ENDS OF FULL HEIGHT WALLS ARE DESIGNATED BY EXTERIOR OF THE BUILDING, CORRIDORS, WINDOWS, OR DOORWAYS, OR AS DESIGNATED ON THE PLANS. SEE PLANS FOR HOLDDOWN REQUIREMENTS. 5. SHEATHING EDGE NAILING IS REQUIRED AT ALL HOLDDOWN POSTS. EDGE NAILING IS REQUIRED TO EACH STUD USED IN BUILT-UP HOLDDOWN POSTS. 6. INTERMEDIATE FRAMING TO BE 2X MINIMUM MEMBERS. FIELD NAILING SHALL BE AT 12” OC MAX. 7. USE 1-1/2” LONG NAILS TO ATTACH FRAMING CLIPS DIRECTLY TO FRAMING. USE 2-1/2” NAILS WHEN CLIPS ARE INSTALLED OVER SHEATHING. 8. AT ADJOINING PANEL EDGES, (2) 2X STUDS NAILED TOGETHER MAY BE USED IN LIEU OF A SINGLE 3XC STUD. DOUBLE 2X STUDS MAY BE CONNECTED TOGETHER WITH 3” NAILS OF THE SAME SPACING AND DIAMETER AS THE PLATE NAILING. 9. WHERE PLATE ATTACHMENT SPECIFIES (2) ROWS OF NAILS, PROVIDE DOUBLE JOIST, RIM, OR EQUAL. 10. USE OF ADHESIVE OR EXPANSION BOLTS IS STRICTLY PROHIBITED. 11. PROVIDE 8D @12” OC AT ALL INTERMEDIATE SUPPORTS (FIELD NAIL) TYP, UNO. 12. INSTALL SHEATHING WITH 1/8” GAP BETWEEN SHEETS FOR EXPANSION/SHRINKAGE 13. STAGGER ALL EDGE NAILS WHERE SPACED AT 3” OC OR LESS. ductless mini-split to serve addition only (min HSPF of 10.00) patch existing wood flooring after casework bench is removed 8" 6" 6"6" 18 " (2 ) 2 x 8 H D R 2/12/23 9825 240th Pl SW Edmonds, WA 98020 RESUB Mar 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT N SCALE DATE: PLANS 41/4" = 1'-0" ELECTRICAL PLAN S S S S S ELECTRICAL SCHEDULE wall mounted light wall mounted light exhaust fan 4" diameter LED dimmable recessed light switch electrical outlet internet/cable outlet +48" AFF Install blocking in wall for future wall mounted tv (5) 8" x 16" crawlspace vents 2x8 HF#2 @ 16" oc 2x8 HF#2 @ 16" oc 6x 1 0 H F # 2 6x 1 0 H F # 2 4x4 post on 18"x18" footing w/ (3) #4 bars each way Sawcut new crawl space access 16" x 24" min DTT2Z holddown, typ EXISTING CRAWL SPACE NEW CRAWL SPACE FOUNDATION PLAN 1/4" = 1'-0" ELECTRICAL PLAN 1/4" = 1'-0" 2/12/23 9825 240th Pl SW Edmonds, WA 98020 S (N) foundation drain to tie into existing New downspout and splash block Install chase in wall to run cables between wall mounted tv above and are behind future furniture below New downspout and splash block RESUB Mar 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCALE DATE: ELEVATIONS 51/8" = 1'-0" WINDOW SCHEDULE A B 3'-0" x 4'-10" CASEMENT WINDOW RELOCATED WINDOW C A B A NORTH ELEVATION SOUTH ELEVATION EAST ELEVATION WEST ELEVATION (N) 2'-8"x6'-8" door (N) asphalt shingle roof to match (E) Infill opening as needed for new door. Siding to match existing (N) downspout and splash block (N) downspout and splash block EXISTING NEW EXISTING NEW NEW EXISTING (N) asphalt shingle roof to match (E) Overframing over (E) roof - cut 1-1/2" diameter holes in (E) roof sheathing @ 8" oc to aid cross-ventilation Overframing over (E) roof - cut 1-1/2" diameter holes in (E) roof sheathing @ 8" oc to aid cross-ventilation 12 4 12 3 existing slope (E ) b l d g h e i g h t C 2'-0" x 6'-0" SLIDING WINDOW 12 ' - 0 " 2/12/23 9825 240th Pl SW Edmonds, WA 98020 Existing downspout and splash block Existing downspout and splash block Existing downspout and splash block RESUB Mar 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SCALE DATE: SECTIONS 6 BUILDING SECTION 1/4" = 1'-0" WALL SECTION 1" = 1'-0" 12 4 RIDGE VENT R-49 INSULATION WALL ASSEMBLY: HORIZONTAL WD SIDING BUILDING PAPER 2x6 @ 24" OC R-21 INSULATION VAPOR BARRIER 1/2" GWB ASPHALT SHINGLES TO MATCH EXISTING FAMILY ROOM R-30 INSULATION 6 MIL BLACK POLY VB CRAWL SPACE +/ - 7 ' - 8 " (M A T C H E X I S T I N G ) 24 " MI N SOFFIT VENT+/- 20" MATCH (E) ASPHALT SHINGLES TO MATCH EXISTING WALL ASSEMBLY: HORIZONTAL WD SIDING BUILDING PAPER 2x6 @ 24" OC R-21 INSULATION VAPOR BARRIER 1/2" GWB SOFFIT (MATCH EXISTING) 1/2" ANCHOR BOLTS @ 6" oc W/ 1/4"x3"x3" PLATE WASHER; 7" EMBED MIN 2x6 PT SILL PLATE 6" 12 " M I N 6" 3"6"3" (1)#4 BOTTOM OF FOOTING #4 @ 48" oc (1)#4 TOP OF STEM WALL 2/12/23 9825 240th Pl SW Edmonds, WA 98020 PERF PIPE FOUNDATION DRAIN COVERED W/ FILTER FABRIC. CONNECT TO EXISTING FOUNDATION DRAINAGE SYSTEM RESUB Mar 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FASTENERS FOR PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A153. IRC R317.3 PRESERVATIVE-TREATED LUMBER REQUIRED WHERE FLOOR JOISTS ARE CLOSER THAN 18" TO THE EXPOSED GROUND, WHERE FLOOR GIRDERS ARE CLOSER THAN 12" TO THE EXPOSED GROUND, ALL WOOD ON CONCRETE OR MASONRY IN DIRECT CONTACT WITH THE GROUND, EXTERIOR SIDING, SHEATHING AND FRAMING WITH A CLEARANCE LESS THAN 6" TO THE GROUND OR 2" TO CONCRETE SURFACES, ANY WOOD ATTACHED DIRECTLY TO THE INTERIOR OF MASONRY OR CONCRETE WALLS BELOW GRADE. SCALE DATE: STRUCTURAL NOTES 7 GENERAL 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTIO N SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE 2018 INTERNATIONAL RESIDENTIAL CODE (IRC) AS AMENDE D BY THE STATE OF WASHINGTON. 2. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. SEE ARCHITECTU RAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW OPENINGS. DESIGN CRITERIA MIN ROOF SNOW LOAD: 25 PSF RESIDENTIAL LIVE LOAD: 40 PSF SEISMIC DESIGN CATEGORY D1 WIND SPEED: 85 MPH (BASIC), 110 MPH (ULTIMATE) WIND EXPOSURE B SS 1.44 S1 0.53 KZT 1.00 ALLOWABLE SOIL PRESSURE: 2000 PSF FOUNDATION 1. FOUNDATION EXCAVATION, BACKFILL, AND COMPACTION SHALL CONFORM SPECIFICATION REQUIREMENTS. THIS CONSTRUCTION WORK, INCLUDING DRAINAGE, SHORING AND SUCH OTHER RELATED WORK AS REQUIRED, SHALL BE CONDUCTED BY THE CONTRACTOR. 2. FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH (CONTROLLED, COMPACTED STRUCTURAL FILL OR BOTH) AT LEAST 18” BELOW LOWEST ADJACENT FINISHED GRADE. 3. ALL ABANDONED FOOTINGS, UTILITIES, ETC. THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE REMOVED. 4. BACKFILL BEHIND ALL WALLS WITH WELL DRAINING, GRANU LAR FILL MATERIAL, AND PROVIDE PERFORATED PIPE DRAINS. CONCRETE 1. ULTIMATE STRENGTH DESIGN PER THE IBC. 2. CONCRETE FOR FOOTINGS SHALL CONFORM TO A 28-DAY STRENGTH OF F’C = 2500 PSI AND SHALL OBTAIN NOT LESS THAN 5-1/2 SACKS OF CEMENT PER CUBIC YARD. 3. REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60, FY = 60,000 PSI 4. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOK S AND BENDS) IN ACCORDANCE WITH ACI 318-19. LAP ALL CONTINUOUS REINFORCEMENT. PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS. LAP CORNER BARS. 5. REINFORCING STEEL LAPS AND EMBEDMENT SHALL BE AS NO TED BELOW: a. DEVELOPMENT LENGTH: 48 BAR DIAM b. DEVELOPMENT LENGTH (TOP BAR): 64 BAR DIAM c. LAP SPLICE LENGTH: 64 BAR DIAM d. LAP SPLICE LENGTH (TOP BAR): 80 BAR DIAM NOTE: TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12” OF CONCRETE IS CASE IN TH E MEMBER BELOW THE BAR. ALL HOOKS SHALL BE “STANDARD” IN ACCORDANCE WITH AC I 318 6. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: a. FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE: 3” b. FORMED SURFACES EXPOSED TO EARTH OR WEATHER: 2” c. SLABS AND WALLS (INTERIOR FACE): 1” CARPENTRY 1. FRAMING LUMBER SHALL BE GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER, LATEST EDITION. 2. ALL LUMBER AT LEAST 2” (NOMINAL) SHALL BE STAMPED SURFACE-DRY AND SHALL HAVE A MOISTURE CONTENT WHEN SURFACED AND WHEN INSTALLED OF NOT MORE THAN 19 PERCENT. LUMBER WITH A LEAST DIMENSION OF 4” (NOMIN AL) OR GRATER SHALL BE STAMPED SURFACE-GREEN AND AIR-DR IED TO A MOISTURE CONTENT OF NOT MORE THAN 19 PERCENT PRIOR TO ITS USE IN FRAMING THE STRUCTURE. 3. PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER FOR THE SPANS AND CONDITIONS AND CRITERIA SHOWN ON THE PLANS AND SHALL BE FURNISHED AND INSTA LLED IN CONFORMANCE WITH THE MANUFACTURER’S PUBLISHED SPECIFICATIONS. THE COMPONENT DESIGNER IS RESPONSIB LE FOR CODE CONFORMANCE, TEMPORARY AND PERMANENT BRACING, AND ALL NECESSARY CONNECTIONS, INCLUDING CONNECTION S TO THE PRIMARY STRUCTURE, NOT SPECIFICALLY CALLED O UT ON THE DRAWINGS. SHOP DRAWINGS SHALL INDICATE THE MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON THE PRIMARY STRUCTURE. ALL NECESSARY BRIDGING, BLOCKING , PRE- NOTCHED PLATES, ETC. SHALL BE DETAILED AND FURNISHE D BY THE MANUFACTURER. PERMANENT AND TEMPORARY BRIDGING SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER ’S SPECIFICATIONS. 3. SHEATHING SHALL BE APA PERFORMANCE RATED PANELS PER APA PLYWOOD DESIGN SPECIFICATION. PANELS MAY BE PLYWOOD OR OSB AS LONG AS THEY MEET THE REQUIREMENTS LISTED HE RE. PANELS SHALL BE GRADE CD. ALL PANELS SHALL BE IDENT IFIED AS EXPOSURE 1. PANEL RATINGS SHALL BE AS FOLLOWS: · PLYWOOD ONLY: ROOF: 5/8” THICK, 32/16 (OR 7/16” THICK, 32/16) · PLYWOOD OR OSB: WALLS: 1/2" THICK, 24/0 (OR 7/16” THICK, 24/0) FLOORS: 3/4" THICK, 48/24 4. UNLESS NOTED OTHERWISE, ROOF AND FLOOR SHEATHING SH ALL BE NAILED WITH 8D NAILS AT 6” OC TO FRAMED PANEL ED GES AND OVER STUD WALLS SHOWN ON PLANS AND 12” OC (10” AT FLOORS) TO INTERMEDIATE SUPPORTS. WALL SHEATHING SHALL BE LAID UP WITH THE LONG DIRECTION PERPENDICULAR TO THE STUDS AND NAILED WITH 8D NAILS AT 6” OC MINIMUM (CLOSER SPACING WHERE NOTED FOR SHEAR WALLS) AND 12” (10” A T FLOORS) TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED SHEATHING EDGE CLIPS AT 16” OC AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HA VE APPROVED TONGUE AND GROOVE JOINTS AND SHALL BE SUPPORTED WITH SOLID BLOCKING. TOENAIL BLOCKING TO SUPPORTS WITH 16D NAILS, UNLESS NOTED OTHERWISE. 5. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWIS E NOTED SHALL BE 2X4 STUDS @ 24” OC AT INTERIOR WALLS AND 2X6 STUDS @ 24” AT EXTERIOR WALLS. TWO STUD MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EA CH SIDE OF ALL OPENINGS AND UNDER THE ENDS OF ALL BEAMS AND HEADERS. UNLESS NOTED OTHERWISE A (2)2X8 HEADER SHA LL BE PROVIDED OVER ALL OPENINGS. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORT BELOW. 6. ALL STUD WALLS SHOWN ON STRUCTURAL DRAWINGS SHALL HAVE THEIR LOWER PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16D NAILS AT 12” OC STAGGERED OR BOLTED TO CONCRETE WITH 5/8” DIAMETER ANCHOR BOLTS AT 4’-0” O C, EMBEDDED 7” UNLESS NOTED OTHERWISE. REFER TO THE STRUCTURAL PLANS AND SHEAR WALL SCHEDULE FOR REQUIR ED SHEATHING AND NAILING. 7. FLOOR FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS. 8. TOENAIL JOISTS TO BEARING SUPPORTS WITH 16D NAILS. UNLESS NOTED OTHERWISE, ATTACH JOISTS TO FLUSH HEADERS OR BEAMS WITH SIMPSON U SERIES METAL JOIST HANGERS TO SUIT JOIST SIZE. ALL DOUBLE JOISTS AND BEAMS SHALL BE CO NNECTED TO FLUSH MEMBERS WITH HU SERIES JOIST HANGERS, UNLE SS NOTED OTHERWISE. STRUCTURAL NOTES 2/12/23 9825 240th Pl SW Edmonds, WA 98020 RESUB Mar 22 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FASTENERS FOR PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. COATING WEIGHTS FOR ZINC-COATED FASTENERS SHALL BE IN ACCORDANCE WITH ASTM A153. IRC R317.3 PRESERVATIVE-TREATED LUMBER REQUIRED WHERE FLOOR JOISTS ARE CLOSER THAN 18" TO THE EXPOSED GROUND, WHERE FLOOR GIRDERS ARE CLOSER THAN 12" TO THE EXPOSED GROUND, ALL WOOD ON CONCRETE OR MASONRY IN DIRECT CONTACT WITH THE GROUND, EXTERIOR SIDING, SHEATHING AND FRAMING WITH A CLEARANCE LESS THAN 6" TO THE GROUND OR 2" TO CONCRETE SURFACES, ANY WOOD ATTACHED DIRECTLY TO THE INTERIOR OF MASONRY OR CONCRETE WALLS BELOW GRADE.