Loading...
ENG2023-0271 ROW PERMIT�~ o� RIGHT OF WAY EUC PERMIT o f EdmondsCity of Edmonds PERMIT NU M 98020 1 1 www.edmondswa.gov i Description: PSE - INSTALL GAS SERVICE FOR MAIN ST COMMONS ISSUED: 06/12/2023 Address: 550 MAIN ST EDMONDS WA 98020-3183 EXPIRES: 12/12/2023 Permit Type: RIGHT OF WAY EUC Permit Subtype: STANDARD Parcel Number: 00434212001500 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT SUSAN SIDICK 1660 PARK LANE, BURLINGTON WA 98233 (425)457-6353 CONTACT PUGET SOUND ENERGY 1660 PARK LANE, BURLINGTON WA 98233 (425)457-6353 CONTRACTOR PSE/INFRASOURCE 1660 PARK LANE, BURLINGTON WA 98233 (425)516-4388 OWNER SEATTLE-SNOHOMISH MILL 9525 AIRPORT WAY, SNOHOMISH WA 98296 COMPANY INC FEE INFORMATIO DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE - PER PERMIT $45.00 $45.00 ENG - INSPECTIONS $378.00 $378.00 RIGHT-OF-WAY PERMIT - STANDARD $378.00 $378.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY: MAJ DATE: 06/12/2023 Printed: Monday, June 12, 2023 2:07:42 PM 1 of 2 RIGHT OF WAY EUC PERMIT s C ` L"F�� City •Edmonds 98020 1 1 www.edmondswa.gov / 425.771i CONDITIONS CONDITION TYPE NOTES ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT NOTES COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL" E-7 CONCRETE SIDEWALK E-7 CURB GUTTER E-7 RESTOR LIMITS Printed: Monday, June 12, 2023 2:07:42 PM 2 of 2 RECEIVED of EpM04O� SECTION A RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal Requirements outlined in Right-of-Wgy permit Handout E6�. Jun 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A' instead of leaving blank. All fields required. Incomplete Applications will be denied. General • Project Name 1o6393285 Site Address or if no site address use Property Address at NW corner of project area: 558 MAIN ST Associated Permits: BLD PLN ENG X Owner and Entity Holding Franchise (if applicable) Name of Company PSE/Infrasource Franchise Ordinance No: Point of Contact Susan Sid ick Title SR Permit Specialist Address 1660 Park lane city Burlington State WA Zip 98233 Phone 425-457-6353 Email susan.sidickapse.com Contractor and Authorized Agent of Owner Name of Company (see note below) Contractor Contacts During Construction Primary Name PSE/Infrasource Susan Sidick Agent Name PSE/Infrasource Title SR Permit Specialist Title SR Permit Specialist Mobile 425-457-6353 Address 1660 Park lane Email susan.sidick@pse.com City Burlington State WA Zip 98233 Secondary Name Phone 425-457-6353 Title SR Permit Specialist Email susan.sidick@pse.com Mobile City of Edmonds Business License No: Email State License No: INFRASL871 C2 [N Contractor verifies it is currently bonded d( Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ix Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) ❑ Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Install gas service at approx work area is approx go' s c/l of main st & 18' w to 25' w c/l of 6th ave S (1) 3x5 paving cut & (1) 3x5 concrete cut anticipated RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF I x LF SF Alley 72 hours + LF Ix I LF SF Parking 72 hours + LF Ix I LF SF 1 SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications ❑ cable ❑ power 3xgas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes No x 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? x If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? x 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? x 5. Does the work involve proposed additions to an aboveground utility stem? If es: x Are the additions for the purpose of serving new commercial development? x Are the additions for the purpose of serving a single-family residential subdivision? x Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? x If yes, answer the following questions related to project area, i.e. the actual area in which the project is proposed: 6a. Does your project involve wires/cables/lines? If yes: x How many are existing? I I How many are to be added? City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: x How many poles are existing in the project area? What is the height of the existing poles? How many poles are to be removed? Are additional poles to be laced? How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: x How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsible for all permit fees. APPLICANT SIGNATURE: Susan Sidick DATE: 05/23/23 APPLICANT PRINTED NAME: Susan Sidick APPLICANT TITLE: SR Permit Specialist NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 Job #: Date: Jurisdiction: ROW Permit: Est. Start Date: Est. Duration: 106393285 Service Address: 5/19/23 City EDMONDS Yes 1 Day (8 Hours) 558 MAIN ST EDMONDS Tin- 98020 Customer: TOM NESS Phone: (425) 263-2474 Customer Email: gecko808O@gmail.com PM / Inspector: Jeffrey Naranjo Phone: (425) 449-6423 Site Contact Email: TNESS@WILCOXCONSTRUCTION.COM Phone: Job Description Project Scope: FROM 2" STW MAIN ON 6TH AVE S** INSTALL 20' OF 1-1/4" ALL SCAT(10STUB/10EXT)SET 2MM AND HANG ONE New Construction: Yes A630** INSTALL 2 - 3 BOLLARDS AS NECESSARY Construction Method COORDINATE WITH MAIN ST Hole Hog Building Foundation Type COMMONS DEVELOPMENT Slab Se tic System No PLAT Map: 163.066 I Z ENGINEERING DIVISION -- --OTED MAIN ST I N 6/07/2022 I— — i i i 60'IROW, II I I " —' I a I I I I I rh I I I I ! Vf PP I 1 vl P I o'lo Dar NICA; charger I----- 5�8 PE I? ----- - — — RESTORATION LIMITS TO BE DETERMINED A630 ON A 2MM I 1 BY CITY ENGINEERING INSPECTOR Mp—t edall repa-pl—all I ;C/L OWNER/CONTRACTOR IS RESPONSIBLE FOR aam_ .arse=°rrt°mage 'mpr°Vemea¢"cry r�gnt-°r-way EROSION CONTROL AND DRAINAGE per city a�andards irat is caps,,, curs during tre permilled pr°le,tcl. I b I OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING P/L I C1 I rl 1 ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. Proposed 1-1/411 SVC _8_'concrete — — — SEWER-LLEV----'8 --------- -- RECEIVED IF N I 8" CIPPJun 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES Work Location Size of Cut Surface Type 90' South of CL MAIN ST & 18' West of CL 6TH AVE S 3 X 5 X 3 A 90' 1 South of CL IMAINST & 25' West of CL 6TH AVE S 3 X 5 X 3 C/G of CL & 1 1 of CL Service Information Street Information Job Type Diameter: Flaggers #: 0 Arterial: No New Commercial Svc EFV: 2 - 10000 9998737 Police #: 0 TCP: Yes le- n rtting Meter: A630 I I Speed Limit: 0 No Parks #: 0 Steel - 1-1/4" x 1-1/4" - Style H17501- 7800671 Meter Loc: 0 Trolley Lines: No Mtr Hoods #: 0 Del Press: 2 PSI Traffic Signal: Bus Stop: No SNO YRD Snohomish Bollards: .5 # 4 # ADA Ramps #: 0 Route #'s: TEMPORARY TRAFFIC CONTROL PLAN BELL ST COORDINATE WITH MAIN ST COMMONS DEVELOPMENT -- ALLEY OVDH o >040M OV021 of 03SO10 O 2130lnOHS 1HSIN i � pl o� i ----------------------MAIN ST-----------;I TRAFFIC CONTROL INSPECTION SHALL BE z REQUIRED WHENEVER WORK ZONE IS SET UP I 'Q I I II � I ENGINEERING DIVISION I .'7TED I �i p(� 16/07/2023 y RESTORATION LIMITS TO BE DETERMINED END o BY CITY ENGINEERING INSPECTOR iiiiiiikIDWORK � I o I i I I•-0ZM i I I QofQ OO_ I i --------------------------100------------ 100' —► -------------------------------- - anolaa OV3HV • , _ * X 1P 03SO1000 i i •a', W NO PARKING SIGN MUST BE W20-1 558 ain St I Q PLACED 72 HOURS IN ADVANCE Ed onds ; OF SCHEDULED WORK DATE WA 98020 I Y � i Q Applicant shall repair/replace all damage to utilities or frontage USA improvements PEE improvements in City right-of-way CLOSED LIMIT i per city standards that is caused or ED 25 I occurs during the permitted project. I i b 00 ALLEY Q OWNER/CONTRACTOR IS RESPONSIBLE FOR 18 18 EROSION CONTROL AND DRAINAGE I o I I I o OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING r') �IHOM avOa ' ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY 4N3 I ROAD UTILITIES MAY REQUIRE A SEPERATE PERMIT. 'i WORK 6 III SIDEWALK HEAD CLOSED 20 I 20 AHEAD rn DETOUR DAYTON ST ------------------------- ----------------------- p Inq---------- G5 N =J yT � -------------------------------- ---------------------------------- I I � I � I I ' I II I , ' I 20 � n V I � I , I Notes: 1. All signs and spacing to conform to the MUTCD and City of Edmonds standards. 2. All sidewalks, driveways, exits and egresses shall be completely clear unless otherwise indicated. 3. Channelizing devices are 28" traffic cones. Use traffic drums (barrels) with steady burning Type C lights on all State Routes and Hwys. 4. Sign size can be a minimum of 36" x 36" and shall not obstruct pedestrian access. 5. Crew is required to leave a minimum of 10' for traveling lane width. 6. Alert affected residents and businesses. 7. Work to take place between 9 a.m. and 4 p.m unless otherwise specified. All work for arterials and major roadways will be from 9 a.m. to 3 p.m 8. Work area will be 90' SCL of Main St & 18-25' WCL of 6th Ave S. 9. If used, place NO -PARK signs 72 hours in advance of the day that the work is to be done. 20 4 SIGN SPACING MPH "X" 60/65 1000, 45/55 500' 35/40 350' 30 200' �_2�;l 100' Q Cz CHANNELIZATION DEVICE SPACING MPH TAPER TANGENT 55/70 40 80 35/45 30 60 25/30 20 40 MINIMUM TAPER LENGTH=L (FT.) LANE WIDTH 20 25 POSTED SPEED (MPH) 30 35 40 45 50 55 60 65 70 10 70 105 150 205 270 475 500 550 - - - 11 75 115 165 225 295 495 550 605 660 - - 12 80 125 180 245 320 540 600 660 720 780 840 RECEIVED Jun 07 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT LEGEND ® WORK PIT ® 28" TRAFFIC CONE TRAFFIC FLOW WORK VEHICLE/ FLASHING LIGHTS SIGN LOCATION RIGHT OF WAY ROW WORK AREA OCHEVRON ARROW BOARD UNIFORMED POLICE OFFICER FLAGGER Puget Sourd E"orgy REV PUGET Designer: Traffic Control Supervisor Safaa AlNeema Szfaa AlNeema 05/23/2023 0 SOUND Nu. 012611 Sa(azEaloeema@P e°com Job # ENERGY (425) 398-6077 (425)398 514166019 Project Address: safaa.alneema@pse.com J 558 Main St, Edmonds, WA 98020 Order # 106393285 Page 1 OF 1