Loading...
BLD2023-0738_Site_Plan_6.12.2023_1.14.53_PM_3603476Edmonds Site Plan Melinda Goforth 8227 198th PI SW Edmonds Wa. 98026 Heat Pump Placement Location Nrop Line Prop .... Line SITE PLAN DRAWING Customer Goforth - 8227 198th PI SW Edmonds Heat Pump Location Under Carport 18227 198th PI SW ji-ropj i i i_ ..--------- Line ... North 23' jvarage p Prop Line M- e A* OPA --AL- 00 .a oo� A Product Data INDUSTRY LEADING FEATURES / BENEFITS A PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND COMFORT. The 38/40MAO series ductless split systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and wires. The fan coil is mounted on the wall, near the ceiling. This selection of fan coils permits creative solutions to design problems such as: • Add-ons to current space (an office or family room addition) • Special space requirements • When changes in the load cannot be handled by the existing system. • When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork. • Historical renovations or any application where preserving the look of the original structure is essential. The ideal compliment to your ducted system when it is impractical or prohibitively expensive to use ductwork. These compact indoor fan coil units take up very little space in the room and do not obstruct windows. The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound levels. AIR FLOW DATA SYSTEM SIZE 9K 12K 9K 12K 18K 24K 30K (115V) (115V) (208-230V) (208-230V) (208-230V) (208-230V) (208-230V) Turbo 380 380 380 380 680 870 870 Indoor High 360 360 360 360 650 780 780 (CFM) Medium 290 300 290 300 450 620 620 Low 210 210 210 210 310 520 520 Outdoor (CFM) 1200 1200 1200 1200 1390 2130 2130 AIR THROW DATA Unit Capacity Max Approximate Air Throw ft. (m) Approximate Air Throw ft. (m) range 9K, 12K 23 (7) 11 (3.5) - 23 (7) 18K 30 (9) 13 (4) - 30 (9) 24K 36 (11) 16 (5) - 36 (11) 30K 36 (11) 16 (5) - 36 (11) SOUND PRESSURE 9K 12K 9K 12K 18K 24K 30K System Size (115V) (115V) (208-230V) (208-230V) (208-230V) (208-230V) (208-230V) Indoor Sound Pressure cooling mode (at dBa 42/34/27 42/34/27 42/34/27 42/34/27 46.5/40/33 50/45/39 50/45/39 different speeds) Indoor Sound Pressure heating mode (at dBa 40/33/26 41/34/27 40/33/26 41/34/27 45/39/32 47/44/38 47/44/38 different speeds) Outdoor sound pressure level dBa 55.5 56 55.5 56 59 60 63 ELECTRICAL DATA UNIT OPER. VOLTAGE COMPRESSOR OUTDOOR FAN INDOOR FAN MCA MAX FUSE SIZE MAX / MIN* V/PH/HZ RLA V/PH/HZ FLA HP W V/PH/HZ FLA HP W CB AMP 127 / 104 115/1/60 5.3 115/1/60 0.14 0.053 40 115/1/60 0.17 0.027 20 15 20 12K 5.7 9K 253 / 187 208-230/1/60 5.3 208-230/1/60 0.42 0.053 40 208-230/1/60 0.07 0.027 20 15 15 12K 5.70 0.42 0.053 40 0.07 0.027 20 15 18K 7.3 0.95 0.067 50 0.17 0.077 58 15 20 24K 8.8 0.47 0.16 120 0.23 0.080 60 15 25 30K 13.5 1.21 0.16 120 0.23 0.080 60 20 30 *Permissible limits of the voltage range at which the unit will operate satisfactorily. LEGEND FLA - Full Load Amps MCA - Minimum Circuit Amps RLA - Rated Load Amps 12