BLD2023-0738_Site_Plan_6.12.2023_1.14.53_PM_3603476Edmonds Site Plan
Melinda Goforth
8227 198th PI SW
Edmonds Wa. 98026
Heat Pump Placement Location
Nrop
Line
Prop ....
Line
SITE PLAN DRAWING
Customer Goforth - 8227 198th PI SW Edmonds
Heat Pump
Location
Under
Carport
18227 198th PI SW
ji-ropj i i i_
..--------- Line ...
North
23'
jvarage p
Prop
Line
M-
e A*
OPA
--AL-
00
.a
oo�
A
Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
A PERFECT BALANCE BETWEEN
BUDGET LIMITS, ENERGY SAVINGS AND
COMFORT.
The 38/40MAO series ductless split systems are a matched
combination of an outdoor condensing unit and an indoor fan coil
unit connected only by refrigerant tubing and wires.
The fan coil is mounted on the wall, near the ceiling. This
selection of fan coils permits creative solutions to design problems
such as:
• Add-ons to current space (an office or family room
addition)
• Special space requirements
• When changes in the load cannot be handled by the
existing system.
• When adding air conditioning to spaces that are heated
by hydronic or electric heat and have no ductwork.
• Historical renovations or any application where
preserving the look of the original structure is essential.
The ideal compliment to your ducted system when it is
impractical or prohibitively expensive to use ductwork.
These compact indoor fan coil units take up very little space in the
room and do not obstruct windows. The fan coils are attractively
styled to blend with most room decors. Advanced system
components incorporate innovative technology to provide reliable
cooling performance at low sound levels.
AIR FLOW DATA
SYSTEM SIZE
9K
12K
9K
12K
18K
24K
30K
(115V)
(115V)
(208-230V)
(208-230V)
(208-230V)
(208-230V)
(208-230V)
Turbo
380
380
380
380
680
870
870
Indoor
High
360
360
360
360
650
780
780
(CFM)
Medium
290
300
290
300
450
620
620
Low
210
210
210
210
310
520
520
Outdoor
(CFM)
1200
1200
1200
1200
1390
2130
2130
AIR THROW DATA
Unit Capacity
Max Approximate Air Throw ft. (m)
Approximate Air Throw ft. (m) range
9K, 12K
23 (7)
11 (3.5) - 23 (7)
18K
30 (9)
13 (4) - 30 (9)
24K
36 (11)
16 (5) - 36 (11)
30K
36 (11)
16 (5) - 36 (11)
SOUND PRESSURE
9K
12K
9K
12K
18K
24K
30K
System Size
(115V)
(115V)
(208-230V)
(208-230V)
(208-230V)
(208-230V)
(208-230V)
Indoor Sound Pressure cooling mode (at
dBa
42/34/27
42/34/27
42/34/27
42/34/27
46.5/40/33
50/45/39
50/45/39
different speeds)
Indoor Sound Pressure heating mode (at
dBa
40/33/26
41/34/27
40/33/26
41/34/27
45/39/32
47/44/38
47/44/38
different speeds)
Outdoor sound pressure level
dBa
55.5
56
55.5
56
59
60
63
ELECTRICAL DATA
UNIT
OPER. VOLTAGE
COMPRESSOR
OUTDOOR FAN
INDOOR FAN
MCA
MAX FUSE
SIZE
MAX / MIN*
V/PH/HZ
RLA
V/PH/HZ
FLA
HP
W
V/PH/HZ
FLA
HP
W
CB AMP
127 / 104
115/1/60
5.3
115/1/60
0.14
0.053
40
115/1/60
0.17
0.027
20
15
20
12K
5.7
9K
253 / 187
208-230/1/60
5.3
208-230/1/60
0.42
0.053
40
208-230/1/60
0.07
0.027
20
15
15
12K
5.70
0.42
0.053
40
0.07
0.027
20
15
18K
7.3
0.95
0.067
50
0.17
0.077
58
15
20
24K
8.8
0.47
0.16
120
0.23
0.080
60
15
25
30K
13.5
1.21
0.16
120
0.23
0.080
60
20
30
*Permissible limits of the voltage range at which the unit will operate satisfactorily.
LEGEND
FLA - Full Load Amps
MCA - Minimum Circuit Amps
RLA - Rated Load Amps