Loading...
FIR2023-0059_Fire_Sprinkler_Equipment_Specification_Sheets_6.9.2023_2.13.04_PM_3600544NOR TNWES T FIRE SYSTEMS 22645 83rd Ave. S., Bldg D * Kent, WA 98032 Ph:206.772.7502 * Fax:206.772.7504 www.nwfiresystems.com LIC # NORTHFS928CR EQUIPMENT SUBMITTAL Johnny Mo's Edmonds, WA NWSF JOB NO. 05339C Pendent / HB (See Fig. 2) Horizontal Sidewall / HB (See Fig. 7) "DuPont Registered Trademark Model F3QR Dry Pendent Sprinkler Model F30R Dry Pendent w/HB Escutcheon "A" Dim. 2" to 48" (51 mm to 1219mm) in %" (6mm) increments "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*(4) Electroless Nickel PTFE (Teflon®) Bronze Brass (3) Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. 4) cULus listed Corrosion Resistant - TJ-�F___�i �- system Tee 1" NPT 2 1/8" Din. Omm] "A" Dimension Hole inCeiling Adjustment Range —1/4" [-6.4mm] 1 43/64" Dia. +1 1/4" [+31.8mm] [42.5mm] 1 1/2" [38.1mm] Total Adjustment Sprinkler Can Ceiling 1 1/4" [31.8mm] 1/4" [6.4mm] Escutcheon Escutcheon Ceiling Adjustment n1 5/8" Nominal Positian� [41.3mm] of Escutcheon 1/4" [6.4mm] Protrusion 3" Did. [76.2mm] NFW15]FC01 Fig. 1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides -1/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed FP Pendent Sprinkler "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon6)*(8) Electroless Nickel PTFE (Teflon" )*(4) Bronze Brass Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Cup and Escutcheon Electroless Nickel PTFE (Teflon°)" Plated. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Ratina Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200oF (93°C) 150°F (66°C) Green H' h(1) 286°F 141°C 225°F 107°C Blue Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green Hi h 286°F 141°C 225°F 107°C Blue Listed and Certified only by cULus. Electroless Nickel PTFE (Teflon®)" Plated sprinklers, escutcheons and cups are recommended for exterior applications. System Tee "A" Dimension 2 1/2" [63.5mm] 1" NPT Adjustment Range Dia. Hole in Ceiling —1/2" [-12.7mm] 3 1/2" [8g. +1 /2" [+12.7mm] eon Dig. EscuthDi Escutheon Adj. Ceiling 1" [25.4] Escutcheon Total Adj. 1/2" [12.7mm] Escutheon Adj. Position Sprinkler Can oNominal f Escutcheon 1-1/4" [31.75mm] 1 Nominal Protrusion 35/8" [41.mm] 2 13/64" [55.88mm] Dia. NEW15]FG02 Fig. 2 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. "I - � System Tee 2 1/2" Dic. [63.50mm] "A" Dimension Hole in Ceiling Adjustment Range 31/4" 2 19/64" Dig. [36.35mm] [58.34mm] Nominal Position of Escutcheon Ceiling 1/4" [6.35mm] Escutcheon Adjustment 1/4" [6.35mm] 3 7/32' Dig. Escutcheon AdjustmentL [81.76mm] 1/2" [12.7mm] Total Adjustment 1" APT Sprinkler Cup Assembly Escutcheon Ceiling NEW157FG03 i Fig. 3 Sprinkler cup and FP Escutcheon fabricated of steel and recommended Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprin- for interior applications. kler in ceilings which have positive pressure in space above. M Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark 2. Model F30R Dry Pendent Concealed Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments ('P rnvor Plata "' Fini¢hoe 121 Standard Finishes Spec! I Application Finishes Chrome Plated Bright Brass Plated White Black Plated Black Paint Off White Satin Chrome Utilizes the 1/2" cover plate with 3/8" total adjustment. �1 Other finishes and colors are available on special order. Consult factory for details. Standard Temperature Ratings Sprinkler Cover Plate Max. Classification Temperature Temp. Rating Ambient Rating Temp. Ordinary 135oF (57oC) 135-F (57oC) 100-F (38oC) Ordinary 155-F (68-C) 135oF (57oC) 100-F (38oC) Intermediate (1) 175oF (79oC) 165oF (74oC) 150'F (66oC) Intermediate 200-F (93oC) 165oF (74oC) 150-F (66oC) High0) 286aF(141aC) I 165oF (74oC) I 150-F (66oC) Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed F1 Pendent Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel Electroless Nickel Electroless Nickel PTFE(Teflon®)*(3) PTFE (Teflon")* PTFE (Teflon")* Chrome Chrome Chrome White Polyester (2) White White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100-F (380C) Orange Ordinary 155-F (68-C) 100-F (38oC) Red Intermediate 1 175'F (79'C) 150OF (66oC) Yellow Intermediate 200-F (93oC) 150OF (66oC) Green High (1) 286aF (1410C) I 2250F (107oC) I Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark - IiIIH -I I- �91 I I -7 L- — System Tee 1" NPT 2 1/2" Dig. [6.35mm] "A" Dimension Hole in Ceiling Adjustment Range f 3/16" 2 19/64" Dig. [t4.76mm] [58.34mm] Nominal Position Sprinkler of Coverplate Cup Assembly Coverplate Ceiling Assembly Ceiling 3/16" [4.76mm] Coverplate Adjustment 3/16" [4.76mm] 3 5/16" Dia. Coverplate Adjustment [84.13mm] 3/8" [9.53mm] Total Adjustment NEW157FG04 Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. �---- v- -------2--MF— II 1 I I ly�iiii I �- System Tee 2 1/2" Dig. " NPT [63.50mm] Hole in Ceiling 1 15/16" "A" Dimension [49.2mm] Adjustment Range t 1/4" [t6.35mm] 15/16" Nominal Position [23.8mm] of Escutcheon Sprinkler Cup Assembly Ceiling 1 /8" Ceiling 1 /4" [6.35] 4" Escutcheon Adjustment 4p(� Escutcheon Adjustment Escutcheon 1/2" [12.7mm] Adjustment 2 27/32 NEW157FG05 [72.2mm] Fig. 5 3. Model F3QR Dry Horizontal Sidewall Sprinkle "A" Dim. 2" to 48" 51 mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon°)"(4) Electroless Nickel PTFE (Teflon®)" Bronze Brass(') Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cLILus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. (4) cULus listed Corrosion Resistant 1 1/2" [38.10mm] Total Adjustment Ceiling r = T 4" [101.60mm] Mir 1 1/4" [31.75mm]a 12" [304.80mm] M Escutcheon Adjustmen System Tee tcheon Adjustment 1" NET 3/32" .18mm] 3" [76.20m m] 2 1/8" Dia. - [53.98mm] Hole in Wall 1/4" [6.35mm] Sprinkler Can Protrusion "A" Dimension Adjustment Nominal Position Range - 1/4" [-6.35mm] of Escutcheon Ne F57Fc06 + 1 1/4 [+31.75mm] Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Model F3QR Dry HSW w/HB Escutcheon "A" Dim. 31/z' to 48" 89mm to 1219mm in 1/4" 6mm increments Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150OF (66°C) Green High 286°F 141°C 225°F 107°C Blue (1) Listed and Certified only by cULus. 1" [25.4mm] Total Adjustment Ceiling 1/2" [12.7mm] Escutcheon Adjustment 4" [101.60mm] Min. mm 12" [304.80mm] Max. Escutcheon Adjustment 2 3/32" System Tee 3 [53.18mm] 1" NPT 2-13/64" 3-1/2" [55.88mm] [88 9mm] Dia. Escutcheon Dia. 2 1/2" Dia. [63.5mm] Hole in Wall 1-1/4" [31.75mm] Nominal Protrusion "A" Dimension Sprinkler Can Escutcheon Adjustment Ncwrnrco� Rongs + 1/2' [+12.7mm] — 1/2" [-12.7mm] Nominal Position of Escutcheon Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Model F30R Dry Recessed FP Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Electroless Nickel PTFE(Teflon11)'(3) Electroless Nickel PTFE (Teflon" )*(4) Bronze Brass Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. "See page 2" (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Sprinkler's can and FP Escutcheon Electroless Nickel PTFE (Teflon")` Plated recommended for exterior applications. Standard Temperature Ratings Classification Sprinkler Tem- erature Rating Max. Ambient Temp. Bulb Color Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200OF (93°C) 150OF (66°C) Green High 286°F 141°C 225°F 107°C Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 F Ceiling 13/32" Escutcheon [35.7mm] 4" [101. imm]Min. System Tee Cup 3 12" [304.fimm]Max.'� �1" NIT 3 7/32" Dia. 81.8m_ �m] 2 1/2" Di [63.5mm] = Nominal Position 1 Hole Wall 3 of Escutcheon 2 19/64" Di.. [58.3mm] 1/4" [6.35] Escutcheon Adjustment "A" Dimension Adjustment Range 1 t0 n Adj t NEWiS�FGOB i1/4" Escutcheon Adjustment [36.35mm] Escut1/4" [6.351 cheon Adjustment =k • FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 8 Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response. Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. "DuPont Registered Trademark 4. Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel Electroless Nickel Electroless Nickel PTFE(Teflon6)"(3) PTFE (Teflon®)` PTFE (Teflon®)' Chrome Chrome Chrome White Polyester (2) White White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (8) cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100-F (38oC) Orange Ordinary 155-F (68oC) 100-F (38oC) Red Intermediate (1) 175oF (79oC) 150oF (66oC) Yellow Intermediate 200-F (93oC) 150-F (66oC) Green High (1) 286aF (141aC) 225aF (107aC) Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Technical Data: Orifice Size:'h" (15mm) Thread Size: 1" NPT per ANSI B2.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F3QR Dry Sprinklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F3QR Dry Sprinklers are intended for use in dry and preac- tion systems and in areas subjected to freezing temperatures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be cor- rosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. When the temperature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. F Ceiling —11 Escutcheon �^1 [3.2mm] �= 4" [101.6mm]Min. System Tee SpAssembly rinkler Cup 1" NPT 3 12" [304.8mm]Max. ref 1 2 27/32" [72.2mm] \\� << 2 1/2" Di �-� [63.5mm] Hole in Wall 31 Nominal Position 1 15/16" [^- of Escutcheon [49.2mm] 1/4" [6.35] Escutcheon Adjustment "A" Dimension 1/2" [12.7mm] NEW157FG09 Adjustment Range Adjustment 31/4" [F6.35mm] 1 [6.35] Escu/4" tcheon Adjustment # • FOR FACTORY MUTUAL (FM) • 4" - 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 9 Listed by cULus for Quick Response. Approved by FM for Standard Response. Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. Ordering Information Specify: 1. Sprinkler Type select one): (a) Model F3QR Dry Pendent (b) Model F3QR Dry Pendent/HB (c) Model F3QR Dry Recessed FP Pendent (d) Model F3QR Dry Recessed F1 Pendent (e) Model F3QR Dry Concealed Pendent (f) Model F3QR Dry Horizontal Sidewall (g) Model F3QR Dry Horizontal Sidewall/HB (h) Model F30R Dry Recessed FP Horizontal Sidewall (i) Model F30R Dry Recessed F1 Horizontal Sidewall 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (F1 or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: "A" Dimension (face of tee to face of ceiling or wall) in (6mm) increments. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI 132.1 [71/2 threads approximately]. 2. All platings and paintings are decorative and intend- ed for interior use. "DuPont Registered Trademark 5. General Installation Instructions Model F3QR dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC", the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F3QR Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 11. During installation, the following steps must be followed 1. Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model F3 or XLO2 Sprinkler Wrench as specified. 3. Install the Model FP push -on / thread -off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F30R Concealed and Recessed In- stallation Instructions • The Model XLO2 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard'/2" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F30R Quick Response Dry Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. Caution: Use specified by RASCO wrenches only, which are designed to engage sprinkler's wrenching pad. (Fig. 15, page 9) RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) AMBIENT TEMPERATURE OF PROTECTED AREA- AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50'F/10'C I 6O'F/16'C EXPOSED MINIMUM BARREL LENGTH'* (FACE OF TEE TO TOP OF CEILING) IN. MM IN. MM IN. MM 40-F (4'C) 0 0 0 30'F (-1'C) 0 0 0 20'F (-TC) 4 (101) 0 0 10'F (-ITC) 8 (203) 1 (25.1) 0 0'F (-16'C) 12 (305) 3 (75) 0 -10'F (-23'C) 14 (356) 4 (101) 1 (25.1) -20-F (-29'C) 14 (356) 6 (152) 3 (75) -30-F (-34'C) 16 (406) 8 (203) 4 (101) -40-F (-4('C) 18 (457) 8 (203) 4 (101) -50-F (-46'C) 20 (508) 10 (254) 6 (152) -60-F (-51'C) 20 (508) 10 (254) 6 (152) INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER WET PIPE INTO THE 1 INCH NPT SIDE OUTLET OF A MALLEABLE IRON TEE FITTING ____ -- PER ANSI B 16.3 (CLASS 150) - ___ OR CAST IRON THREADED TEE FITTING i n u PER ANSI 16.4 (CLASS 125) ONLY. LATc___� Lr-` 1J IF HUMIDITY AND TEMPERATURE DIFFERENTIAL fi CAUSES CONDENSATION ON THE EXPOSED DRY I SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING i TAPE OR EQUIVALENT. MINIMUM (HEATED AREA) EXPOSED SEAL THE CLEARANCE SPACE BARREL AROUND THE SPRINKLER TO AVOID LEAKAGE OF AIR INTO THE PROTECTED LENGTH AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. 'A' CLEARANCE DIMENSION HOLE i • THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING, THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES LISTED, USE THE NEXT COOLER TEMPERATURE. )— //�l � THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. CEILING) ESCUTCHEON NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH WIND VELOCITIES IN THE PROTECTED AREA. (PROTECTED AREA) r3" DIA. *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE MINIMUM (HEATED AREA) (HEATED AREA) MINIMUM EXPOSED EXPOSED BARREL BARREL LENGTH DECKTITE FLASHING — INSIDE FACE SEAL LENGTH (SEE ABOVE) RASCO /4003910 (SEE ABOVE) (RECOMMENDED) 1 CLEARANCE HOLE i I INSULATED FREEZER i OR COOLER STRUCTURE OR EXTERIOR FRAMING (PROTECTED AREA) w DRY SPRINKLER (PROTECTED AREA) DRY SPRINKLER IN COLD AREA W_ SIN COLD AREA NEW157FG10 Fig. 10 7. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION FEMALE FEMALE PIPE PIPE . THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE 1 SHORTER LONGER INLET INLET MALE MALE PIPE PIPE THREAD THREAD MODEL F3-PL, MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3, DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fgO8A Fig. 11 m Fig. 12 - XL02 Wrench Fig. 13 - XL02 Wrench 15- Fig. 14 - XL02 Wrench 0 Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co., Inc. ® Recycled ® (800) 431-1588 Sales Offices Paper Relleiabi (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 01/14 P/N 9999970175