BLD2023-0740_Site_Plan_6.13.2023_9.29.31_AM_36053772018 International Fire Code (IFC)
Chapter 12 ENERGY SYSTEMS
1204.2.1.1 Pathways to ridge.
Not fewer than two 36-inch-wide (914
mm) pathways on separate roof plane,
from lowest roof edge to ridge, shall be
provided on all buildings. Not fewer than
one pathway shall be provided on the
street or driveway side of the roof. For
each roof plane with a photovoltaic array,
not fewer than one 36-inch-wide (914 mm)
pathway from lowest roof edge to ridge
shall be provided on the same roof plane
as the photovoltaic array, on an adjacent
roof plane or straddling the same and
adjacent roof planes.
DRIVEWAY
36" Pathway
FORECAST
SOLAR
1 (425) 487-6000 1
Address: 12820 Avondale Way
Everett, WA 98204
Email: info@ForecastSolar.com
Address: 17806 73rd PI W
Edmonds, WA 98026
Phone: 206-850-5132
Equipment
Array Size
16.32 kW
Modules
34-QCELLS XL 10
Module Wattage
48OW
Module Color
Silver -framed
Module Dimension
41.35x87.5x35mm
Inverter
Enphase
Inverter Model
IQBA
Optimizer
NA
Racking System
IronRidge
Racking Color
Silver
Mounts
52-IronRidge FRA
204" XR100 Rails
12
168" XR100 Rails
4
124" XR100 Rails
0
Splice Kits
10
Grounds
5
End Clamp
12
Mid Clamps
64