Loading...
ENG2023-0238 ROW PERMIToff' EIDM �~ o�RIGHT OF WAY EUC PERMIT o , UM EdmondsCity of Edmonds PERMIT NU 98020 www.edmondswa.gov i Description: COMCAST-OVERLASH 260' THEN UG 176' THROUGH EXISTING CONDUIT ISSUED: 06/16/2023 Address: 21701 76TH AVE W EDMONDS WA 98026-7536 EXPIRES: 12/16/2023 Permit Type: RIGHT OF WAY EUC Permit Subtype: MINOR Parcel Number: 00580700002702 CONTACTS NAME TYPE NAME ADDRESS PHONE APPLICANT JESSAMIN SANTOS 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188 CONTACT COMCAST CABLE COMMUNICATIONS 410 VALLEY AVE NW, PUYALLUP WA 98371 (206)401-2188 MANAGEMENT, LLC CONTRACTOR CABLECOM LLC 19910 NORTHCREEK PARKWAY N, BOTHHELL WA 98011 (363)608-6700 OWNER HR ACQUISITION I CORPORATION PO BOX 92129, SOUTH LAKE TX 76092 FEE INFORMATION DESCRIPTION AMOUNT PAID CITY TECHNOLOGY FEE - PER PERMIT $45.00 $45.00 ENG - INSPECTIONS $252.00 $252.00 RIGHT-OF-WAY PERMIT - MINOR $126.00 $126.00 REQUIREMENTS REQUIREMENT TYPE NOTES TRAFFIC CONTROL Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their posession. RESTORATION Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday - No Exceptions WARRANTY The contractor is responsible for workmanship and materials for a period of one year following the final inspection and acceptance of the work. INSPECTION SCHEDULING: WWW.MYBUILDING PERMIT.COM 24 HR NOTICE REQUIRED INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including but not limited to the defense of any legal proceedings including defense costs and attorney fees by reason of granting this permit. RELEASED BY: MAJ DATE: 06/16/2023 Printed: Friday, June 16, 2023 1:14:48 PM 1 of 2 o RIGHT OF WAY EUC PERMIT f PERMIT NUM of Edmonds EdmondsCity 98020 www.edmondswa.gov i CONDITIONS CONDITION TYPE NOTES ALERT RESIDENTS ALERT AFFECTED RESIDENTS AND OR BUSINESSES PRIOR TO WORK START. It is the owner's responsibility to repair/replace all damage of utilities or frontage improvements in DAMAGE TO FRONTAGE City right of Ways or Easements to City Standards caused by or occurring during the permitted IMPROVEMENTS project. MAINTAIN EROSION AND SEDIMENTATION CONTROL PER CITY AND SWMMW STANDARD ESC REQUIREMENTS REQUIREMENTS. Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of whatever nature, arising directly or indirectly from the HOLD HARMLESS issuance for this permit. Issuance of this permit shall not be deemed to modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance provision. SCHEDULE REQUIRED INSPECTIONS AS NOTED THROUGH MY BUILDING PERMIT. INSPECTIONS www.mybuildingpermit.com POTHOLING VERIFY CLEAR BORE CROSSINGS. RESTORE LANDSCAPE Restore landscape to like or better conditions Sound or noise originating from temporary construction sites as a result of construction activity are exempt from the noise limits of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on SOUND AND NOISE weekdays and 10:00am and 6:00pm on Saturdays, excluding Sundays and Federal Holidays. At all other times the noise originating from construction sites and activities must comply with the noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120. All utilities shall be located prior to any excavation. New locates shall be called for if at time of UTILITY LOCATES excavation, original locates are no longer identifiable. INSPECTIONS INSPECTION TYPE DATE RESULT COMPLETE A-1 JOB START E-7 TRAFFIC CTRL X-2 ENGINEERING FINAL" Printed: Friday, June 16, 2023 1:14:48 PM 2 of 2 RECEIVED of EpM04O� SECTION A RIGHT OF WAY CONSTRUCTION PERMIT APPLICATION Complete and submit this Application in accordance with the Submittal Requirements outlined in Right-of-Wgy permit Handout E6�. May 05 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT If any field is not applicable to your project, write "N/A' instead of leaving blank. All fields required. Incomplete Applications will be denied. General • Project Name JB-1335034 Site Address or if no site address use Property Address at NW corner of project area: 21701 76th AVE W, EDMONDS ,WA 98026 Associated Permits: BLD PLN ENG Owner and Entity Holding Name of Company Comcast Cable Communications Management, LLC. Franchise Ordinance No: Point of Contact Jessamin Santos Title Permit Coordinator Address 410 Valley Ave NW City Puyallup State WA Zip 98371 Phone (2o6) 401-2188 Email jessamin_santos@cable.comcast.com Contractor and Authorized Agent of Owner Name of Company Cablecomm, LLC (see note below) Contractor Contacts During Construction Primary Name CHRIS ATKINSON Agent Name Leah Ihlenfeldt Title Construction Supervior Title Permit Coordinator Mobile 36o-926-3437 Address 1316 BONNEVILLE AVE ,BLDG A, Email CHRIS.ATKINSON@CABLECOMLLC.NET City Snohomish State wA Zip 98290 Secondary Name Phone (36o) 668-1300 Title Email leah.ihlenfeldt@cablecomllc.net Mobile City of Edmonds Business License No: NR-o21818 Email State License No: CABLE-971DP ® Contractor verifies it is currently bonded ® Contractor verifies it currently has general liability insurance NOTE: ECDC 18.6o. o2o requires that the Application be signed by a licensed and bonded contractor unless otherwise approved by the city engineer. ❑ Multifamily residential ❑ Commercial ❑ City project ❑ Single family residential subdivision ❑ Single family -other ❑ Industrial ❑ Demo and rebuild or from vacant land? ❑ Other, please specify: ❑ Utility Franchise Work associated with development (check one of the above boxes as welt ❑ Traffic Control Only (no associated development) X Utility Franchise Work (no associated development) City of Edmonds ROW construction permit Application --Page 1 of 3 Updated 3/25/2021 Include an overall narrative description of the proposed work. Be specific and detailed: Describe infrastructure to be impacted, such as, poles, wires, conduit, utility mains, etc. Include whether this is construction, maintenance, or repair. Include description of proposed construction methods, (e.g., bores, trenches, overhead wires proposed, depth for underground utilities, etc.) Comcast JB 1335o34 The proposed work in the ROW is to overlash 26o' of 48ct fiber to existing Comcast strand along 76TH AVE W; proof existing Comcast riser / buried conduit 176', pull new 48ct fiber to address 21701 76th AVE W. No disturbance of surface. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (Number of Months) Sidewalk 72 hours + LF x LF SF NA Alley 72 hours + LF x LF SF NA Parking 72 hours + LF x LF SF NA SECTION B - If you are not a utility company performing work in the City ROW, skip to SECTION C. 1. The work in the right of way is on or for the following type of facilities: ❑ telecommunications X cable (fiber) ❑ power ❑ gas ❑ water ❑ sewer ❑ storm Details of Work to be Completed 1. Does the utility owner have existing overhead infrastructure in the area of work? Yes X No 2. Will any equipment be added underground or above ground (e.. pedestals, vaults, etc.)? X If yes, describe: 3. Does the proposed work connect a lot or commercial development with utilities that serve more than one lot or commercial development? X 4. Does the work involve rebuilding or relocating an existing aboveground utility system which connects a lot or commercial development to an existing underground common utility stem? X 5. Does the work involve proposed additions to an aboveground utility stem? If es: X Are the additions for the purpose of serving new commercial development? X Are the additions for the purpose of serving a single-family residential subdivision? X Details of Work to be Completed Yes No 6. Does your project involve rebuilding or replacing utility equipment which currently serves more than one lot or commercial development? If yes, answer the following questions related to project area, i.e. the actual area in which the X project is proposed: 6a. Does your project involve wires/cables/lines? If yes: X How many are existing? 1 1-2 1How many are to be added? 1 City of Edmonds ROW construction permit Application --Page 2 of 3 Updated 3/25/2021 6b. Does your project involve poles? If yes: X How many poles are existing in the project area? 3 What is the height of the existing Poles? 35-50 How many poles are to be removed? o Are additional poles to be laced? no How many? I I What is the height of the additionalpoles? 6c. Are any poles to be modified/rebuilt/replaced? If yes: X How many? I I What is the height of the poles after? Describe the modification rebuild: SECTION C Traffic Control and Public Safety. Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by WAC 296-155-305 and must have certification verifying completion of the required training in their possession. Restoration. Restoration shall be in accordance with City codes and Standards. All street cut trench work shall be patched with asphalt or City approved material prior to the end of the workday -NO EXCEPTIONS. Insurance. The City may require the owner or contractor to provide proof of insurance acceptable to the City prior to any permit approval. Indemnification. The Applicant agrees to defend, indemnify, and hold harmless the City of Edmonds, its officials, officers, employees, and agents against any injuries, damages, or claims of any kind or description whatsoever, foreseen or unforeseen, including defense costs and attorney fees, resulting directly or indirectly from any act or omission of the Applicant, its subcontractors, anyone directly or indirectly employed by them, and anyone for whose acts or omissions they may be liable, arising out of, related to, or by reason of the granting of this permit; and specifically including but not limited to all loss by the failure of the Applicant to fully or adequately perform, in any respect, all authorizations or obligations under the permit. These indemnification requirements shall survive the expiration, revocation, or termination of any resulting permit approval. Acceptance of terms, conditions, and requirements. Applicant accepts the terms, conditions, and requirements set forth in this Application and agrees they apply to any resulting permit and shall comply with them to the satisfaction of the City Engineer. Applicant further agrees to comply with the conditions listed on the Submittal Requirements; with all applicable city ordinances, including but not limited to ECDC Title 18; and with all applicable requirements of state and federal law. Statement of Applicant. I declare under penalty of perjury under the laws of the State of Washington that: I am a licensed and bonded contractor; the information provided herein is correct and complete; and I am authorized by owner to act on its behalf and have authority to bind the owner to this application. Fees. The Applicant is responsibleforall permit fees. APPLICANT SIGNATURE: Je SaW(n , Saht0S APPLICANT PRINTED NAME: Jessamin Santos APPLICANT TITLE: Permit Coordinator NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE 4/28/2023 City of Edmonds ROW construction permit Application --Page 3 of 3 Updated 3/25/2021 OVERVIEW Completed By: Nathan Lindae-Fregoso Address: 21701 76TH AVE W STE 206 EDMONDS WA 98026 Completion Date: 1/30/2023 Right of Way Footages: CST OMCA Job Type: Metro E Retail New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 176 New Aerial Fiber: 0 Overlash Fiber: Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Fiber Survey Scope: Post=Sale Project Manager: P2 ID: JB0001335034 Legend Provide Clear Construction Details 1. TIE IN AT SP0554.WALY. 2. BEGIN FIBER OVERLASH DOWN 3 POLES 2 SPANS 260'. 3. BEGIN PROOF AND PULL THROUGH EXISITNG UG 176' TO 2ND FLR DEMARC. 4. BEGIN NEW INTERIOR PATH THROUGH CEILING 100' FOLLOWING EXISTING COAX New Ped � DROP. 5. PLACE PROPER FIBER EQUIPMENT IN CUSTOMER STE TELECO CLOSET. ENGINEERING DIVISION I\ E D RECEIVED G G N G New Vault Applicant shall repair/replace all OWNER/CONTRACTOR IS RESPONSIBLE damage to utilities or frontage EROSION CONTROL AND DRAINAGE FOR OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING �r "OTED ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY May 05 2023 improvements in City right-of-way per city standards that is caused or occurs during the UTILITIES MAY REQUIRE A SEPERATE PERMIT. / II — �v 16/08/2023 CITY OF EDMONDS DEVELOPMENT SERVICES Existing U/G permitted project. DEPARTMENT Existing Aerial 3 1 New U/G a New Aerial NEW INTERIOR PATH ^ MAIN DEMARC LOCATED THROUGH CEILING ON 2ND FLR. EXISITING Interior Path _ -� P. -' TAP FEEDING STE •'1 FOLLOWING EXISITNG COAX DROP 100' -I ` T �- Exterior Building Path Footage Break EXISITNG COMMS POLE. EXISTING 2" �_ on 2ND FLR CUSTOMERSFIBER PLACE ti DEMARC PROPER F RISER EQUIPMENT IN TELECO . ' _ CLOSET. Fiber Splice Point WFI -_ Storage Loop_ —4 176' Riser e 60' R Pole . PROOF AND PULL THROUGH EXISTING UG Lock Box Footage - 176' INTO 2ND FLR DEMARC. — 2' 00 - - low Text Box / FIBER OVERLASH � DOWN 3 POLE 2 SPANS _ Callout Arrow New Tap Text 220' (span length) - Phase Identifier Power Suppy 1 o L- Hard Surface Cut TIE IN SP0554.WALY. LOCATED ON SPAN. O > f • x Abandoned Cable a _ \ Bak RIGHT OF WAY Completed By: Nathan Lindae-Fregoso Address: 21701 76TH AVE W STE 206 EDMONDS WA 98026 Completion Date: 1/30/2023 Private Exterior Footages: COMICAST Job Type: Metro E Retail New Aerial Coax: 0 Overlash Coax: 0 New UG Fiber: 0 New Aerial Fiber: 0 Overlash Fiber: 0 Existing UG Fiber: 0 Empty Conduit Only: 0 New UG Coax: 0 Existing UG Coax: 0 Are Additional Pages Needed: No Job Subtype: Fiber Survey Scope: Post -Sale Project Manager: P2 ID: JB0001335034 •Provide Clear Construction 1. TIE IN AT SP0554.WALY. 2. BEGIN FIBER OVERLASH DOWN 3 POLES 2 SPANS 260'. 3. BEGIN PROOF AND PULL THROUGH EXISITNG UG 176'TO 2ND FLR DEMARC. 4. BEGIN NEW INTERIOR PATH THROUGH CEILING 100' FOLLOWING EXISTING COAX New Ped F1 DROP. 5. PLACE PROPER FIBER EQUIPMENT IN CUSTOMER STE TELECO CLOSET. RECEIVED May 05 2023 New Vault 0 CITY OF EDMONDS DEVELOPMENT Existing U/G DEPARTMENT •�`: Existing Aerial New Ll/G New Aerial 01 .a z Interior Path lAft i Exterior Building Path Footage Break /,j-� y, • SIP :✓.4 .�i•: _ .. _ot .:CStorage Fiber Splice Point �/q1 / � , ...CD } ''1 , !' '�"ice' /� � � _ r-i _ ' TR ',,�+�T11 AN•, 1 �� 's.►� 4�1 ��� 15 / �� �: s Riser iA Pole Lock Box • • .,•t • �.e i z. For r'k �.- i� f ►, •. ` Lease �.. Text .. �..�., = tii`bText Callout Arrow New Tap 9 •- .. I • ' ai R .�c 2 MM TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. c 45 MPH 1 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 1 123' 172' 74' 100, 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED Z--,"==- CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/60 40 80 35145 30 60 25130 20 40 W20-1 MINIMUM TAPER LENGTH = L (feet) Lane Width (feet) Posted Speed (mph) 25 30 35 40 45 50 55 60 65 70 10 105 150 1 205 1 270 1 450 1 500 1 550 - - - 11 115 165 225 295 495 550 605 660 - - 12 125 180 1 245 1 320 1 540 1 600 SIGN SPACING = X (FEET) ( 1 ) RURAL HIGHWAYS 60165 MPH 8001± RURAL ROADS 45/55 MPH 500'± RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350'± RURAL ROADS, URBAN ARTERIALS 25/30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200'± (2) URBAN STREETS 25 MPH OR LESS ALL SIGNS ARE 48" X 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. Spotter to assist pedestrians (1) All spacing may be adjusted to accommodate interchange through work zone ramps, at -grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. KEEP MAINTAIN TWO 11' W1-4L W20-1 24'4x s0" � TRAVEL LANES ROAD o WORK BAN RIGHT AHEAD 30' MIN. i 20', 1 100' MAX. , R, B L/2 X X 'VK INIH o a a ° 76th Ave W o WORK AREA ° l7 0 1� a o o o— — °0 -9 0 12-0 0 00 09 12 12° — — o-M o— �j E 0 71 -E 2ft min. recommended 0 IT]° a ® El ao a a � X X L/2 L/2 DEVICE SPACING 1/2 DISTANCE FOR ROAD WORK IN SIGN LOCATION SIGN LOCATION - S MOUNTING ® HEIGHT -RECOMMENDED 0 0 0 CHANNELIZING DEVICES EM PROTECTIVE VEHICLE REQUIRED OPPOSING TRAFFIC DEVICES NOTES 1. For long term projects, conflicting pavement markings no longer applicable must be removed or obliterated as soon as practicable. Temporary markings shall be used as necessary and signs shall LANE be post mounted. CLOSED Applicant shall repair/replace all AHEAD damage to utilities or frontage 2 For speed limits of 30 mph or less, use sign W1-3 in lieu of sign W1-4. improvements in City right-of-way W20-51- per city standards that is caused or 3. Extend device taper across shoulder if applicable. occurs during the permitted project. 4. Protective vehicle with TMA required for roadways 45 mph or higher. For roads 40 mph or less - shall be a work vehicle placed strategically to shield work area. TYPICAL LANE SHIFT WITH TWO WAY LEFT TURN LANE TCP 22 OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROLAND DRAINAGE OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. 0 0 ry RECEIVED May 05 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP WORK ZONE CONDITION (SEE CHAPTER 1.9.10) A - ALLOWED - CONSIDER USING A SPOTTER. KEEP AT LEAST ONE LANE OPEN AT B - ALLOWED - SPOTTER RECOMMENDED CONSIDER ADDITIONAL WARNING SIGNS. ATIME WHERE FEASIBLE. C - NOT ALLOWED - SEE TCP 14 & 15 FOR ADDITIONAL WORK ZONE REQUIREMENTS. I FLAGGERS TO HOLD TRAFFIC FOR OVERLASH CROSSING Approximate hold time of 5 min per crossing attempt. WORK 76th Ave W 11 AREA ------------- - ROAD µZ n BE W n WORK PREPMEO AHEAD _sL ro arov - o V_"E—E KEEP R� I Fr_Fnln ® WORK VEHICLE W/ WARNING BEACON ¢ (LOCATE TO SHIELD WORK VEHICLE) OS SPOTTER RECEIVED May 05 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SIGHT DISTANCE DATA MINIMUM STOPPING SIGHT DISTANCE = S SPEED LIMIT 25 30 35LO4 50 55LO6 70 MPH DISTANCE155 FEET 200 250 425 495 730 DISTANCES SHOWN ARE MINIMUMS, USE ADDITIONAL DISTANCE WHEN POSSIBLE. GENERAL LIMITS OF CHANNELIZED INTERSECTION KEEP RIGHT Spotter to assist pedestrians through work zone NOTES: 1. Work vehicle w/beacon located in same quadrant as work location. 2. Repeated access to work lane not allowed. see tcp 14 & 15 for work zone requirements - condition "C". 3. Restricted sight distance requires additional advance warning devices or signs, see sight distance data chart. 4. Recommend working during red phase if signalized. 5. See chapter 1.9.10 - 1.9.11 for additional direction . "ROAD WORK AHEAD" signs to be TYPICAL VERY SHORT DURATION WORK OPERATION (INTERSECTION APPLICATION) placed On all public road approaches to TCP 29 work area or advance sign area. 2 ry MM TRAFFIC CONTROL INSPECTION SHALL BE REQUIRED WHENEVER WORK ZONE IS SET UP BUFFER DATA LONGITUDINAL BUFFER SPACE = B SPEED (MPH) 25 30 35 40 45 50 55 60 65 70 LENGTH (feet) 155 200 250 305 360 425 495 570 645 730 TMA ROLL AHEAD DISTANCE = R HOST VEHICLE WEIGHT 9,900 TO 22,000 Ibs. HOST VEHICLE WEIGHT > 22,000 Ibs. c 45 MPH 1 45-55 MPH > 55 MPH < 45 MPH 45-55 MPH > 55 MPH 100' 1 123' 172' 74' 100, 150, PROTECTIVE VEHICLE (WORK VEHICLE) = R NO SPECIFIED DISTANCE REQUIRED CHANNELIZING DEVICE SPACING (FEET) MPH TAPER TANGENT 50/60 40 80 35145 30 60 25130 20 40 MINIMUM TAPER LENGTH = L (feet) Lane Width (feet) Posted Speed (mph) 25 30 35 40 45 50 55 60 65 70 10 105 150 1 205 1 270 1 450 1 500 1 550 - - - 11 115 165 225 295 495 550 605 660 - - 12 125 180 1 245 1 320 1 540 1 600 SIGN SPACING = X (FEET) ( 1 ) RURAL HIGHWAYS 60165 MPH 8001± RURAL ROADS 45/55 MPH 500'± RURAL ROADS & URBAN ARTERIALS 35/40 MPH 350'± RURAL ROADS, URBAN ARTERIALS 25/30 MPH RESIDENTIAL & BUSINESS DISTRICTS 200'± (2) URBAN STREETS 25 MPH OR LESS ALL SIGNS ARE 48" X 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. Spotter to assist pedestrians (1) All spacing may be adjusted to accommodate interchange through work zone ramps, at -grade intersections, and driveways. (2) This spacing may be reduced in urban areas to fit roadway conditions. R4-713 KEEP MAINTAIN TWO 11' W1-41- W20-1 TRAVEL LANES ROAD 24" x 30" BAN RIGHT AHEAD 30' MIN. i 20', 1 100' MAX. , R, B L/2 X X 'VK INIH 0 a a ° 76th Ave W 0 WORK AREA ° 0 1� a goo 0 o - 00 -9 0 12-0 0 00 09 0 00 - - 0-0 0- 0 0 ®M 71 D -E 2ft min. recommended❑ 0 IT] —0oi�0000000000000000000o a a a � X X L/2 L12 DEVICE SPACING 1/2 DISTANCE FOR OPPOSING TRAFFIC DEVICES ROAD NOTES WORK 1. For long term projects, conflicting pavement markings no longer AHEAD applicable must be removed or obliterated as soon as practicable. W20-1 Temporary markings shall be used as necessary and signs shall LEGEND LANE be post mounted. CLOSED IN SIGN LOCATION AHEAD 2. For speed limits of 30 mph or less, use sign W1-3 in lieu of sign W1-4. SIGN LOCATION - S MOUNTING W20-5L 3. Extend device taper across shoulder if applicable. ® HEIGHT -RECOMMENDED 0 0 0 CHANNELIZING DEVICES 4. Protective vehicle with TMA required for roadways 45 mph or higher. For roads 40 mph or less - shall be a work vehicle placed strategically PROTECTIVE VEHICLE REQUIRED to shield work area. TYPICAL LANE SHIFT WITH TWO WAY LEFT TURN LANE TCP 22 RECEIVED May 05 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 0 0 IV