APPROVED FIR BLD BLD2023-0622+Architectural_or_Building_Floor_Plans+5.22.2023_10.20.08_AM+3559547_ 41, 3 n 1330 S.F. SECOND FLOOR OCCUPANCY CURRENTLY 'B' WITH OFFICE SPACES STORAGE AT 100 S.F. / OCCUPANT 202 GROSS = 14 TOTAL OCCUPANTS N 33 SF EXG STUDIO OCCUPANCY _ PROPOSED TO BE CHANGED M �— TO EVENT ROOM AND UNCONCENTRATED ASSEMBLY — OCCUPANCY AT 15 S.F. / 22 OCCUPANTS OCCUPANT NET �► 2' 8" —2'- 81 - — — — Lit _ STAIR 1 N 214 0 r--28 49 SF KITCHENETTE 203 107 SF 17 2 OCCUPANTS j Irtlqr OFFICE 1 204 � 0 132 SF • � 2 OCCUPANTS CLO 211 BRIE0 20 16 SF 60 4OCCUPANTS \ 2 cI_o 210 14 SF TOILETF�7 CORK - 46 SF L OFFICE 2 0 - .-• 205 176 SF Ar 135 SF • _ - 2 OCCUPANTS CLO " 209 rte + 20 SF STAIR 2 _ 5 213 52 SF STORAGE L - 98 SF ROOF ACCESS DOOR Jor JL abo �. I v e ) APP OVE PLANS UST BE ON J B SITE ALL WORK SUBJECT TO FIELD INSPEP ION FOR CODE CO PLIANCE G&A 2nd FLOOR PLAN 3 1 1 /4" = V-0" ***NO CHANGES TO TRASH RECEPTACLES OR LOCATION APPROVED UNDER THIS PERMIT. IF CHANGES ARE PROPOSED PLEASE CONTACT THE CITY OF EDMONDS TO DETERMINE WHAT PERMITS MAY BE REQUIRED.*** 4 SCOPE OF WORK: THE SECOND FLOOR OF GLAZED AND AMAZED PLANS TO USE THE LARGE ROOM AT THE FRONT OF THE BUILDING, FACING MAIN STREET, AS AN EVENT ROOM FOR BIRTHDAY PARTIES, CLASSES, AND WORKSHOPS. EVENTS WOULD BE HELD IN THIS SPACE 3-5 TIMES A WEEK. THE THREE SMALLER ROOMS AT THE BACK OF THE BUILDING ARE USED FOR OFFICE AND STORAGE SPACES. NO OTHER CHANGES ARE BEING PROPOSED GLAZED AND AMAZED CURRENTLY HAS 7 EMPLOYEES. - 4 N Approved DFM Chris gust South County Fire Date: 06/09/2023 06-09-2023 PLAN REVIEW APPROVED WITH CONDITION: 1. CHANGE OF USE REQUIRES A FIRE ALARM SYSTEM TO BE INSTALLED THOUGHOUT THE BUILDING. PER ECDC 19.25.035. C.3. DFM BURT LEGEND FE/FEC 28 EXIT ROUTE WITH OCCUPANCY NUMBER 278 ....• :::::. ... • .•• . • ::•• ... .. I tt ..: • :.,. :-,•; I •: ..•: . _ :=.=.. = =:: •� 9 0 t .' -:-. ols .. ••..: '• - .:_. ... :,:........... .............. �:�:•:�......:: .. ... •. ... ..•.... :.... r ...•.... , ....... ...•: • .... ... •- - :: :•. :•: Jos o,66C - -- - � •; • :-. . .:.. -- •. • .. •. ., -�. .•. •. . • • :• - . . •: - . _•: : ... .•. ......... •: • • . •: • . . •• • • • r .:: 1 1ZZ J------ "I's ZORS -ys PLM M001s , a6ej G&A 1st FLOOR PLAN GLAZED AND AulttLV15YM1 •J 2ND FLOOR EVENT ROOM CHANGE OF OCCUPANCY 514 MAIN STREET UNIT B EDMONDS WA 98020 CODE ANALYSIS 2021 IEBC, 2021 IBC, AND ASSOCIATED LOCAL BUILDING CODE AMENDMENTS. SUMMARY: ZONING: BD-1 City Of Edmonds USE / OCCUPANCY: M - MERCANT LE (1ST FLR) Building Department B - OFFICE (2ND FLR) _______ CONSTRUCTION TYPE: V-B (NS) Work ;----------- CHANGE OF OCCUPANCY AUTOMATIC SPRINKLER SYSTEM: NO Address. 514 MAIN B TABLE 506.2 - ALLOWABLE AREA: 9000 SF-_=__=_=- ACTUAL AREA 1st FLR: 1738 SF Owner: GLAZED AND AMAZED ACTUAL AREA 2nd FLR: 1330 SF Approved Dater 06/06/2023 TOTAL AREA 3086 SF TABLE 504.3 - ALLOWABLE HT: 40' Building Official ACTUAL HEIGHT: 30' Permit Number'---------- BLD2023-0622 TABLE 504.4 - ALLOWABLE STORIES: M-OCCUPANCY (1ST FLR) 1 STORY (COMPLIES) CONSTRUCTION TYPEB B-OCCUPANCY (2ND FLR) 2 STORIES (COMPLIES) TABLE 508.4 - SEPARATION BETWEEN OCCUPANCIES OCCUPANCY GROUPS NONE REQUIRED BETWEEN M AND B OCCUPANT LOAD 22— event r PER IEBC - CHAPTER 5 PRESCRIPTIVE METHOD UTTty SECTION 502 - DOES NOT APPLY, THERE ARE NO ADDITIONS TO THIS FACILITY SECTION 503 - DOES NOT APPLY, THERE ARE NO ALTERATIONS TO THIS FACILITY SECTION 504 - DOES NOT APPLY THERE ARE NO FIRE ESCAPES EXISTING OR REQUIRED AT THIS FACILITY SECTION 505 - DOES NOT APPLY, THERE ARE NO WINDOWS AND EMERGENCY ESCAPE OPENINGS EXISTING OR REQUIRED AT THIS FACILITY SECTION 506 - CHANGE OF OCCUPANCY SHALL COMPLY WITH THE IBC REQUIREMENTS FOR THE NEW OCCUPANCY, EXCEPT CHAPTER 16 PER THE EXCEPTION: THIS CHANGE OF OCCUPANCY IS NOT CHANGING GRAVITY OR LATERAL LOADS. THE EXISTING BUILDING ENVELOPE, STRUCTURE, AND ALL INTERIOR CONSTRUCTION ARE REMAINING AS IS. SECTION 506.4 - STAIRWAY IS NOT REQUIRED TO COMPLY AS THE EXISTING CONSTRUCTION DOES NOT ALLOW A REDUCTION IN PITCH OR SLOPE. SECTION 506.5 - STRUCTURAL ELEMENT DEMAND CAPACITY RATIO IS NOT BEING INCREASED BY MORE THAN 5%, THEREFORE COMPLIANCE WITH 506.5 IS NOT REQUIRED. SECTION 507 - THIS FACILITY IS NOT DESIGNATED AS AN HISTORIC PROPERTY. PORTABLE FIRE EXTINGUISHERS ARE PROVIDED AND INSTALLED PER SECTION 906 MEANS OF EGRESS TWO EXITS PROVIDED (ONE ACCESSIBLE) THE TRAVEL DISTANCE FROM ANY POINT IN THE SPACE TO AN EXIT IS LESS THAN 75 FEET. EXG STREET PARKING - 2 CARS EXG BUILDING SIGN TO REMAIN N FRONT OF BUILDING \\ \\ \ CCESSIBLE ENTRANCE EXISTING ENTRY s s V a *, TO SECOND FLOOR V. -- -- TO REMAIN * • .To pogirt-- 1 PROPOSED PROJECT - LOCATION - 1GLAZED AND AMAZED 514 MAIN STREET, UNIT B 1 PROPERTY LINE (ASSUMED. (FACE OF BUILDING — , ) JACENT PARKING T (NOT GLAZED D AMAZED) — SH AND RECYCLE IN =Y BEHIND BUILDING DING IN ALLEY IND BUILDING ALLEY BETWEEN MAIN AND DAYTONoP'— SITE PLAN 1 " = 20'-0" ,oa., �GI8TtERED AAc 7WT Q (AURA M. STRAUSg STATE OF WASHtNfiTON 0 Ln CD CD M 00CD 0 o N V; ra o Ln Ln i-u C N 0 0 0 � v � 0 l/'1 G 'N J v 6 J Q o N � O (00 U Q � O LL. o O z w w 0 � � 0w = Z = m ::D � U ~ Q w Q U) � z c caLU Q � N L0 Q J CD REVISION SCHEDULE # DESCRIPTION DATE RECEIVED 5/22/23 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2023-0622 JOB NO. 2023-008 DATE 15 MAY 2023 DRAWN LMS REVIEWED Ims SHEET NAME CofO PLANS AND CODE REVIEW SHEET NO. �) Al