Loading...
REVIEWED FIR2022-0106+Fire_Sprinkler_Equipment_Specification_Sheets+10.10.2022_1.17.25_PM+3155591Bulletin 006 June 2021 Relmlabld Features cULus Listed as Residential Sprinklers Push -On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in accordance with UL 199. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible -link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible -link operating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are intermediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model G5 cover plate. Model G5 cover plates are installed by pushing the cover plate into the cup and turning in the clockwise direction until it is tight against the ceiling. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model G5 cover plates are available in a variety of finishes as listed in Table H. Model RFC Series Residential Sprinklers Flat Concealed Pendent RECEIVED Oct 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Model RFC30 & RFC30LL Model RFC49 & RFC49LL Model RFC76 cULus Listed FI R2022-0106 Model RFC43 & RFC43LL Model RFC58 'Am Model G5 Cover Plate Sprinkler Model p Nominal K-Factor gpm/psi'l2 (I/min/bar'12) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20 (6.1 x 6.1) WILLS RA0618 cULus: CULLS Listed to UL199, Automatic Sprinklers for Fire -Protection Service. LL: CULLS Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals Bottom View J cULus Listed to UL 199 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Model RFC30 & RFC30LL Sprinkler Components and Dimensions Threa Body Cup Tower Fusible Lii Deflector (retrac Pin (exten( Deflector (exten( 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling i OOBFIG01_02_W Model G5 Cover Plate Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria 2-5/16" (58 mm) Cup Dia. uia. 2-5/8" (67 mm) Hole in Ceiling 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure M Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14 x 14 10 -7 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 2 of 8 June 2021 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed to UL 199 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Model RFC43 & RFC43LL Sprinkler Components and Dimensions Threa - Body Cup Tower Fusible Lit Deflector (retrac Pin (extended) - Deflector (extended) -s 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling 006FIGa1 az oa Model G5 Cover Plate Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Bottom View 2-5/16" (58 mm) Cup Dia. IM 3-5/16" (84 mm) Dia. 2-5/8" (67 mm) Hole in Ceiling 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure f'I Max. Coverage Area izl Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (1/min) (bar) (1/min) (bar) 15 x 15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16 x 16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table C above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 3 of 8 June 2021 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sensitivity Fast -response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Bottom View Cover Plate Finishes Listings and Approvals cULus Listed to UL 199 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions Threa - Body Cup Tower Fusible Lii Deflector (retrac Pin (exten( Deflector (exten( 1-3/4" (44 mm) +/- 1/4" (6 mm) Nominal face of fitting to ceiling 006FIG01_0203 Model G5 Cover Plate Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria 2-5/16" (58 mm) Cup Dia. aw 3-5/16" (84 mm) Dia. 2-5/8" (67 mm) Hole in Ceiling 3/16" (5 mm) Ceiling Minimum Flow and Residual PressureM Max. Coverage Area (z) Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (1/min) (bar) (1/min) (bar) 16 x 16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18 x 18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20 x 20 20 16.7 21 18.4 (6.1 x 6.1) (75.7) (1.15) (79.5) (1.27) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table D above and (2) the flow required to achieve a mini- mum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 4 of 8 June 2021 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed to UL 199 Model RFC58 Sprinkler Components and Dimensions Bottom View 2- (58 mm) Threads Cup Dia. Body Cup Tower 2 5/8" (67 mm) Fusible Link 1 7/8" (48 mm) +/- 3/8" (9 mm) Hole in Ceiling Nominal face of fitting to ceiling 3/16" Deflector (retracted) — (5 mm) Pin (extended) H H ""6F�"4A Deflector (extended) — �3-==F��3== F� 3-5/16" Model G5 Cover Plate (84 mm) Ceiling Dia. Model RFC58 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual PressureN Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 5 of 8 June 2021 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Min. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast -response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench -able cap) Model W3 (with wrench -able cap) Listings and Approvals cULus Listed to UL 199 Model RFC76 Sprinkler Components and Dimensions Threads Body Cup �` Tower Fusible Link Deflector (retracted) — Pin (extended) — Deflector (extended) — F1 =` Bottom View ti 2-5/16" (58 mm) Cup Dia. 1-7/8" (48 mm) +/ 3/8" (9 mm) Nominal face of fitting to ceiling OOBFIG05A Model G5 Cover Plate Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria 3-5/16" (84 mm) Dia. jrHole in Ceiling 2-5/8" (67 mm) 3/16" (5 mm) Ceiling Minimum Flow and Residual Pressure0) Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (1/min) (bar) 16 x 16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18 x 18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20 x 20 34 20 (6.1 x 6.1) (128.7) (1.4) Notes: 1. For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in Table E above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Reliable Page 6 of 8 June 2021 www.reliablesprinkler.com Cover Plate Finishes0) Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Custom color paint is semi -gloss, unless specified otherwise. 3. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the back side. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Recommended Min. to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceilings') Ceiling Rating inch (mm) inch (mm) RFC30, G5 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC30LL (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 135°F(2) RFC43LL, G5 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, (84) (67) (13) (38 to 51) (13 to 25) or 165°F­ RFC49LL (74°C) RFC58, G5 3-5/16 2-5/8 3/4 1-1 /2 to 2-1/4 1 /4 to 1 13oor 1655E 3C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 112" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. 2. For use with 165T (74°C) temperature rated sprinklers where the maximum ceiling temperature does not exceed 100T (38°C). 3. For use with 212T (100°C) temperature rated sprinklers where the maximum ceiling temperature does not exceed 150°F (66°C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench -able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench -able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque for iron pipe fittings is 8 to 18 ft-Ibs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-Ibs (19 to 27 N-m) for 3/4" thread sprinklers. Note: When used with gasketed fittings, follow fitting manufacturer's installation instructions regarding tightening to achieve a leak -free connection. Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Bulletin 006 June 2021 Page 7 of 8 www.reliablesprinkler.com Model FC For use with Model RFC Series sprinklers without wrench -able cap installed Model W8 High -strength plastic wrench for limited (emergency) use with Model RFC Series sprinklers without wrench -able cap installed. Meets NFPA requirements for sprinkler wrench on premises. Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non -operation. Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Model W3 For use with Model RFC Series sprinklers with wrench -able cap installed Listings and Approvals �J Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL 199, Automatic Sprinklers for Fire -protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwriters Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler • Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) • Temperature Rating Cover Plate • Model G5 • Temperature Rating • Finish (See Table H) Sprinkler Wrench • Model FC • Model W3 • Model W8 (Limited use) R. Bulletin 006 June 2021 Page 8 of 8 www.reliablesprinkler.com Bulletin 014 August 2021 limabile Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FRXLH & F1 FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model F1 FR40 Sprinkler Types Standard Spray Pendent Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 Recessed Sprinkler Types Standard Spray Pendent Model F1 FR56LL & F1 FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Con- tent Listing & Approvals The following organizations provide Listings or Approvals for various Model F1 FIR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprinkler. 1. Underwriters Laboratories Inc. and Certified for Cana- da (cULus) in accordance with ANSI/UL199. 2. FM Approvals (FM) 3. Loss Prevention Certification Board (LPCB) 4. VdS SchadenverhOtung GmbH (VdS) 5. Underwriters Laboratories Inc. and Underwriters Lab- oratories of Canada Certified for Health Effects to NSF/ ANSI Standard 61 Annex G (ULH) 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) (EC) 7. WaterMark certified. Certificate Number 23347. (WM) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Model F1 FR Series Quick Response Glass Bulb Sprinklers Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model F1 FR series sprinklers are quick -response automatic sprinklers with a glass bulb thermal element. Model F1 FIR series sprinklers are Standard Spray sprinklers, with the exception of the Model F1 FR56 Conventional sprinkler which is XLH Recessed an Old-style/Conventional sprinkler. Pendent FP The Model F1 FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FIR Series sprinklers to apply water to a fire faster than standard -response sprinklers of the same tem- perature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufac- tured glass capsule. This glass bulb is specially constructed to provide fast thermal response. co S 0 D c c N O N Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. Model F1 FIR Series sprinklers provide a wide range of options where quick -response, glass bulb sprinklers are used: • Pendent, recessed pendent, upright, horizontal side - wall, and vertical sidewall deflectors • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) • Flush, recessed, and concealed installations See the Design and Installation Information table in this Bul- letin for information on the approvals and availability of specific Model F1 FIR series sprinkler configurations. Model F1 FIR Recessed Pendent and Recessed Horizontal Sidewall sprinklers are required to be used with Reliable Model F1, F2, or FP recessed escutcheons. See the Recessed Es- cutcheon Data table in this Bulletin for listing and approval infor- mation with each specific Model F1 FIR series sprinkler. Model F1 and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2- inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cover plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.Omm) of cover plate adjustment. See the Design and Installation Infor- mation and Listed and Approved Temperature Ratings tables in this Bulletin for further information on approved cover plate options. Application Model F1 FIR Series sprinklers are intended for use in ac- cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Having Juris- diction. Care must be exercised that the k-factor, tempera- ture rating, deflector style, and sprinkler type are in accor- dance with the requirements of the applicable design and installation standards. In addition, Model F1 FIR Series sprin- klers must be used in accordance with their listings and ap- provals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or protec- tive caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Re- move the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protec- tor before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1 FIR Series sprinklers must be installed with the Reli- able sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model F1 FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the specific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1 FIR Series Recessed sprinkler. The use of any other recessed escutcheon will void all approvals and negate all warranties. Concealed Sprinklers Model F1 FIR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers have a facto- ry -installed Model CCP cup. A protective cap is installed at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread- off cover plate assembly. The cover plate and sprinkler cup as- semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1 FIR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1 FIR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model W4 wrench is used to engage the sprinkler wrenching sur- faces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent dam- age to the sprinkler. Do not wrench any other part of the sprinkler/ cup assembly. Installation is completed by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/ cup assembly other than the Reliable Model CCP with Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not spe- cifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick -response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm Pendent 2.25 57 W2 RA1411 cULus 2 F1 FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 W4 RA1411 cULus 2 Upright 2.25 57 W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 W4 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 1 57 W4 RA14131 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1 FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 W4 RA1410 cULus, ULH F1 FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 W4 RA1413 cULus 2 (F1 FR42 4.2 60 7/16 10 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 cULus, FM, Pendent 2.25 57 W2 RA1414 LPCB, VdS, EC, 1,2,3,4 WM cULus, FM, Recessed Pendent 2.25 57 W4 RA1414 LPCB, VdS, EC, 1,2,3,4 WM F1 FR56 5.6 80 1 2 15 Concealed Pendent 2.25 57 W4 RA1414 cULus VdS,EC, WM 5,6 cULus, FM, Upright 2.25 57 W2 RA1425 LPCB, VdS, EC, 1,2,3,4 WM "Conventional (Pendent or Upright)" 2.25 57 W2 RA1475 LPCB, VdS, EC, WM 4 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 1 57 W4 RA14151 cULus, ULH FlFR56LL 5.6 80 1/2 15 Concealed Pendent 2.25 57 W4 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 FlFR56 5.6 80 1/2 15 Recessed Horizontal Sidewall 2.63 67 W4 RA1435 cULus, FM 8 F1 FR56 5.6 80 1/2 15 Vertical Sidewall (Pen- dent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 (') cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. (1) cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. (1) Available with FM approved Polyester coating in black or white. (4) Available with LPCB and VdS approved Polyester coating. (1) VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 1550F (68°C) temperature rated sprinklers only. VdS approved sprinklers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. (1) Model F1 FR56 Concealed Pendent and Model F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. (') cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1 FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (1) cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (1) The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the F1 FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100T (38*C) Max. Ambient Temp. Intermediate Temp. Classification 150T (65*C) Max. Ambient Temp. High Temp. Classification 225T (107°C) Max. Ambient Temp. 135°F (57°C) Temp. R ting 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286T (141°C) Temp. Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1 FR28 Recessed Pendent cULus Upright cULus Pendent VdS F1 FR40 Recessed Pendent VdS Pendent cULus F1 FR42 Recessed Pendent cULus Upright cULus FlFR42LL Pendent Recessed Pendent cULus, ULH cULus, ULH Pendent cULus F1 FRXLH Recessed Pendent cULus Upright cULus Pendent cULus, FM, LPCB, VdS, EC, WM Recessed Pendent cULus, FM, LPCB, VdS, EC, WM F1FR56 Concealed Pendent cULus, WM cULus,, dS,EC, WM cULus, WM Upright cULus, FM, LPCB, VdS, EC, WM "Conventional Pendent or Upright)" LPCB, VdS, EC, WM Pendent cULus, ULH F1FR56LL Recessed Pendent cULus, ULH Concealed Pendent' EA9E���cULus, ULH Horizontal Sidewall cULus, FM F1 FR56 Recessed Horizontal Sidewall cULus, FM r1F1 FR56 Vertical Sidewall (Pen- dent or Upri ht cULus, FM, LPCB * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For In- termediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model F1 Model F2 Model FP Model Deflector/ (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1 FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 FlFR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 FlFR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC, WM RA1414 EC, WM VdS, EC, WM FlFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 9 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS --�\\ F7 ESCUTCHEONr//1� 3/4'[19mm] e1 ADJUSTMENT F2 ESCUTCHEON 112'T 12.7mm] ADJUSTMENT 2 114" HOLE DIA. [57.2mm] 1 15116" DIA [49.2mmJ l F S i i -1 II II L J� 2 27132" DIA. [72.2mmJ 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = i'[25.4mm] AT MINIMUM RECESS = 318'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'[19mm] AT MINIMUM RECESS = 318'T9.5mmj F1 ESCUTCHEON AT MAXIMUM RECESS = 7/8'T22.2mm] [3.2mmJ AT MINIMUM RECESS = 1-5/8'[41.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'[28.6mm] AT MINIMUM RECESS = 1-5/8'T41.3mm] Fig.1 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR421-L, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon I I 1 " X 1/2"' REDUCER -----I----- 2 5/8" DIA. [66.7mm] HOLE IN CEILING 1 I 2 5/16" DIA. [58.7mm] CUP L J CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION - AT MAXIMUM RECESS = 1-1/2"T38mm] AT MINIMUM RECESS = 1 'T25.4mm] AT MAXIMUM RECESS = 9/16'T14.3mm] %2'T 12.7mm] AT MINIMUM RECESS = 1 'T25.4mm] ADJUSTMENT 3 1/4" DIA. [82.6mm] Fig. 2 Model F1 FR56, F1 FR56LL, F1 FR42, F1 FR40, F1 FR42LL, F1 FRXLH & F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = I 'T25.4mm] AT MINIMUM RECESS = 318'T9.5mm] E2 ESCUTCHEON AT MAXIMUM RECESS = 3/4'T 19mm] AT MINIMUM RECESS = 3/8'T9.5mm] 2 114" HOLE DIA. [57.2mm] 1" X 112" REDUCER i i um I 1 15116" DIA. / uw [49.2mm] of um � um i TURN COLLAR UNTILu TIGHT AGAINST SPRINKLER WRENCH BOSS. 118" [3.2mm] F1 ESCUTCHEON AT MAXIMUM RE ESS 1 3 8" 34 9 C = - / [ . mm] AT MINIMUM RECESS = 2-1/16'T52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mm] AT MINIMUM RECESS = 2-1/16'T52.4mm] 2 27/32" DIA. [72.2mm] F1 ESCUTCHEON 3/4'T 19mm] ADJUSTMENT F2 ESCUTCHEON 1/2'T 12.7mm] ADJUSTMENT 1 (1) 4"-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR oiarcoM RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 escutcheon I" x 112" REDUCING TEE OR ELBOW 2 5116" DIA — CUP CEILING 2 518 " DIA. HOLE IN CEILING 1 112 " MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION I 112 " MAX. COVER ADJUSTMENT j COVER PLATE / ASSEMBL Y 3 5116 " DIA SPRINKLER 15/16" CONCEALED. 1 /2" ADJUSTMENT 017FG01A Fig. 4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate Al I" x TEE 112" REDUCING OR ELBOW _ 2 5116" CEILING 5116 " MAX. --I COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER - 2 518" DIA. HOLE IN CEILING 1 112 " MAX. FACE OF FITTING TO FACE OF CEILING """' DIMENSION CONCEALED, 5/16" ADJUSTMENT 017FG02A ncealea renaent sprinKler wltn low inch (8.Omm) adjustment - Model CCP cover plate Maintenance The Model F1 FIR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover late0) Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated (400 White Painted Special Application Finishes S rinkler Escutcheon Cover late0) Electroless Nickel PTFEM Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2)(6) Black Paint Off White Off White(2)(6) Off White Satin Chrome Chrome Dull I Chrome Dull (1) Other finishes and colors are available on special order. Consult the fac- tory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi -gloss, unless specified otherwise. (2) cULus Listed only. (3) 200°F (93°C) maximum. (4) cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. (5) FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (6) LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. (') cULus listed Corrosion Resistant 514" Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: 1. Sprinkler Model: [F1 FR28][F1 FR40][F1 FR42] [F1 FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] 2. Sprinkler Deflector/Orientation: [Pendent][Recessed Pendent] [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] 3. Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] 4. Sprinkler Temperature Rating: [135'F (57°C)][155'F (68°C)][175°F (79°C)][200°F (93°C)][286°F (141°C)] 5. Sprinkler Finish 6. Escutcheon Model: [F1][F2][FP] 7. Escutcheon Finish (where applicable) 8. Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.Omm) adjustment] 9. Cover plate Temperature Rating: [135'F (57°C) for use with Ordinary Temperature sprinklers][165°F (74'C) for use with Intermediate Temperature sprinklers] 10. Cover plate Finish Note: When Model F1 FIR Series Recessed sprinklers are ordered, the sprin- klers and escutcheons are packaged separately. 7. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many pre- cision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper Reliabld (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 08/21 P/N 9999970300 UponorAquaPEX®White, coils Submittal information Revision M: Sept. 18, 2018 Project information Job name: Location: Part no. ordered: Uponof Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Crosslinked polyethylene PEX-a Engel Method; PEX 5106 Standard grade hydrostatic ratings (PPI): 200°F (93°C) at 80 psi (551 kPa) 180°F (82°C) at 100 psi (689 kPa) 73.4°F (23°C) at 160 psi (1,103 kPa) '/2", %", 1", 1'/4", 1'/2" and 2" UponorAquaPEX® White only: --- 120°F (49°C) at 130 psi (896 kPa) Linear expansion rate: 1.1'/10°F/100' (27.94mm/5.56°C/30.48m) Product information and application use Uponor AquaPEX White is used for hot and cold domestic potable water distribution and residential fire safety as well as radiant heating/cooling and hydronic piping systems containing no ferrous corrodible components or where ferrous components are isolated from the piping. ✓ Description Part number I.D. O.D. Weight '/4' Uponor AquaPEX White, 100-ft. coil F1040250 0.241" 0.375" 4.0 lbs. Uponor AquaPEX White, 400-ft. coil F1090375 0.350" 0.500" 20.0 lbs. Uponor AquaPEX White, 1,000-ft. coil F1120375 0.350" 0.500" 44.0 lbs. ''/2" Uponor AquaPEX White, 100-ft. coil F1040500 0.475" 0.625" 6.0 lbs. %" Uponor AquaPEX White, 300-ft. coil F1060500 0.475" 0.625" 18.0 lbs. ''/z" Uponor AquaPEX White, 500-ft. coil F1100500 0.475" 0.625" 27.6 lbs. ''/z" Uponor AquaPEX White, 1,000-ft. coil F1120500 0.475" 0.625" 54.0 lbs. Uponor AquaPEX White, 300-ft. coil F1060625 0.574" 0.750" 28.0 lbs. Uponor AquaPEX White, 1000-ft. coil F1120625 0.574" 0.750" 86.0 lbs. Uponor AquaPEX White, 100-ft. coil F1040750 0.671" 0.875" 10.0 lbs. Y44" Uponor AquaPEX White, 300-ft. coil F1060750 0.671" 0.875" 34.0 lbs. %" Uponor AquaPEX White, 500-ft. coil F1100750 0.671" 0.875" 54.0 lbs. 1" Uponor AquaPEX White, 100-ft. coil F1041000 0.862" 1.125" 20.0 lbs. 1" Uponor AquaPEX White, 300-ft. coil F1061000 0.862" 1.125" 56.0 lbs. 1" Uponor AquaPEX White, 500-ft. coil F1101000 0.862" 1.125" 93.0 lbs. 1'/4' Uponor AquaPEX White, 100-ft. coil F1061250 1.054" 1.375" 34.0 lbs. 1'/4" Uponor AquaPEX White, 300-ft. coil F1021250 1.054" 1.375" 106.0 lbs. 1'/z" Uponor AquaPEX White, 100-ft. coil F1061500 1.244" 1.625" 44.0 lbs. 1'/z" Uponor AquaPEX White, 300-ft. coil F1021500 1.244" 1.625" 133.0 lbs. 2" Uponor AquaPEX White, 100-ft. coil F1062000 1.629" 2.125" 68.2 lbs. 2" Uponor AquaPEX White, 200-ft. coil F1052000 1.629" 2.125" 136.4 lbs. 2" Uponor AquaPEX White, 300-fit. coil F1022000 1.629" 2.125" 204.6 lbs. 2'/i' Uponor AquaPEX White, 100-ft. coil F1062500 2.011" 2.625" 88.0 lbs. 2'/i' Uponor AquaPEX White, 300-ft. coil F1022500 2.011" 2.625" 264.0 lbs. 3" Uponor AquaPEX White, 100-ft. coil F1063000 2.400" 3.125" 128.0 lbs. 3" Uponor AquaPEX White, 300-ft. coil F1023000 2.400" 3.125" 384.0 lbs. Installation Use ProPEX® fittings for %" through 3" pipe.' Refer to the ProPEX Connections Instructional Guide, Uponor Piping Pocket Guide, Plumbing Design Assistance Manual (PDAM), Complete Design Assistance Manual (CDAM), Hydronic Piping Design Assistance Manual (HPDAM) or AquaSAFET1A Residential Fire Sprinkler Installation Guide for more information. Listings2 Codes Standards cNSFus-fs3; cNSFus-pw; cQAlus P321; UL; IAPMO; ICC; IPC; IMC; IRC; ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM CSA; PPI TR-4; ICC-ES; BMEC; CCMC UPC; UMC; NSPC; HUD; F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; UFGS; NPC of Canada; ASTM E814/ULC S115; CSA B137.5; CSA B214; NBC of Canada UL 18213; ULC/ORD-C199P3; AWWA C9044 Related applications Contact information PEX-a plumbing systems Uponor, Inc. Uponor Ltd. AquaSAFETM fire safety systems 5925 148"' Street West 6510 Kennedy Road Radiant heating and cooling systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Hydronic piping systems Phone: 800.321.4739 Phone: 888.994.7726 Fax: 952.891.2008 Fax: 800.638.9517 uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEX- is a trademark of Uponor Ltd. 2Visit listing agency's website for complete information. 3For 3/4", 1" and 1'W pipe only. 4For %" to 3" pipe. ProPEX° Ring Submittal information Revision I: Nov. 1, 2018 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Engel -method crosslinked polyethylene (PEX-a) Density: 926 to 940 kg/m3 Degree of crosslinking: 70% to 89% Product information and application use Uponor ProPEX® rings are required to make a proper ProPEX connection.' The ProPEX ring with stop includes a leading edge chamfer and stop edge. ✓ Description Part number ProPEX Ring, %" ProPEX Ring with Stop, '/2" ProPEX Ring with Stop, %" ProPEX Ring with Stop, 3/4" ProPEX Ring with Stop, 1" ProPEX Ring with Stop, 1'/4" ProPEX Ring with Stop, 1'/2" ProPEX Ring with Stop, 2" ProPEX Ring with Stop, 2'/2" ProPEX Ring with Stop, 3" Installation Q4690302 Q4690512 Q4690625 Q4690756 Q4691000 Q4691250 Q4691500 Q4692000 Q4692500 Q4693000 uponof Length I.D. O.D. Weight 0.54" 0.49" 0.74" 0.005lbs. 0.63" 0.63" 0.87" 0.006lbs. 0.79" 0.75" 1.00" 0.008lbs. 0.87" 0.88" 1.13" 0.012lbs. 1.10" 1.13" 1.42" 0.020lbs. 1.35" 1.38" 1.66" 0.030lbs. 1.61" 1.63" 1.91" 0.040 lbs. 1.97" 2.14" 2.61" 0.133lbs. 2.61" 2.66" 3.25" 0.230lbs. 3.12" 3.16" 3.87" 0.400lbs. Square cut the Uponor PEX tubing. Remove excess material. Slide the ProPEX ring over the end of the tubing (maximum 'lid' over -hang for rings without stop). When using the ProPEX ring with stop, slide the ring on the tubing with the chamfered edge first until the end of the tubing contacts the stop edge. Expand the tubing and ring. If using the ProPEX Manual Expander Tool, rotate the tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. Make ProPEX connections at temperatures above 5°F/-15°C. For more information, refer to the Uponor ProPEX Connections Instructional Guide. Listings' cNSFus-fs3; cNSFus-pw; cNSFus-rfh; cQAlus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC; cQAlus P321 Codes ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; CSA 13137.5; CSA B214; UL 18213; ULC/ORD-C199P3 Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. AquaSAFE fire safety systems 5925 148"' Street West 6510 Kennedy Road Hydronic radiant heating and cooling systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Snow melting systems Phone: 800.321.4739 Phone: 888.994.7726 Turf conditioning systems Fax: 952.891.2008 Fax: 800.638.9517 Permafrost prevention systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEXT" is a trademark of Uponor Ltd. 2Visit listing agency's website for complete information; 3For '/2",'/", 1", 11/", 1'/2" and 2" tubing only ProPEXO Engineered Submittal information Revision H: May 23, 2019 Project information Job name: Polymer (EP) Tee Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved bv: Technical data Material: Engineered polymer (EP) Maximum temperature (no pressure): 320°F (160°C) Maximum working temperature/pressure: 210*F (99*C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) tees make diverting connections for Uponor crosslinked polyethylene (PEX-a)tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXTM tubing.' Note: Branch size is listed last in the part descriptions. Uponof Part ✓ Equivalent Equivalent cv cv Description number A B Weight length (ft.) length (ft.) through branch through branch ProPEX EP Tee, ''M." PEX x'/z' PEX x'/" PEX Q4755060 2.50" 1.53" 0.02 lbs. 1.0 6.3 7.7 3.4 ProPEX EP Tee, %" PEX x'/:' PEX x'/:' PEX* Q4757575 3.30" 1.94" 0.05 lbs. 1.5 15.6 15.7 5.4 ProPEX EP Tee, 1" PEX x 1" PEX x 1" PEX* Q4751010 4.10" 2.47" 0.07 lbs. 1.3 12.7 30.5 11.3 ProPEX EP Tee, 1'/4" PEX x 1'/4" PEX x 1'/4" PEX* Q4751313 4.80" 3.22" 0.15 lbs. 3.8 8.6 34.0 23.9 ProPEX EP Tee, 1 Yz' PEX x 1'/." PEX x 1'M." PEX Q4751515 5.80" 3.82" 0.25 lbs. 1.8 10.6 63.7 31.0 ProPEX EP Tee, 2" PEX x 2" PEX x 2" PEX Q4752000 7.45" 4.79" 0.38 lbs. 0.8 15.5 150.7 52.5 ProPEX EP Tee, 21/' PEX x 21/z' PEX x 21/z' PEX Q4752500 10.56" 5.45" 1.14 lbs. 2.7 22.3 197.2 81.5 ProPEX EP Tee, 3" PEX x 3" PEX x 3" PEX Q4753000 12.26" 6.37" 1.86 lbs. 2.8 23.9 286.6 122.8 Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor Professional Plumbing Installation Guide, AquaSAFET"^ Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards ASTM E84; ASTM E119; ASTM E814; ASTM F877; ASTM F1960; CAN/CSA B137.5; NSF 14; NSF 61 Codes IBC; IMC; IPC; IRC; NPC of Canada; NSPC; UMC; UPC Listings cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information PEX-a plumbing systems Uponor, Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 148t' Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFETm fire safety systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEXT" is a trademark of Uponor Ltd. ProPEX° Engineered Polymer (EP) Reducing Tee (up to 11/2") uponof Submittal information Revision I: Sept. 16, 2019 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Engineered polymer (EP) n� Maximum temperature (no pressure): 320°F (160°C) Max. working temperature/pressure: 210°F (99°C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) reducing tees make diverting connections for Uponor PEX-a pipe for use in hot and cold B domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX11 or Wirsbo hePEXTM pipe.' Note: Branch size is listed last in the part descriptions. ✓ Description Part A B Weight Equiv, length (ft.) Equiv. length Cv Cv number through (ft.) branch through branch ProPEX EP Reducing Tee,''/2" PEX x'/i' PEX x %" PEX Q4755575 2.86" 1.76" 0.03 lbs. 1.0 15.6 7.7 5.4 ProPEX EP Reducing Tee, '/<" PEX x'/i' PEX x'/i' PEX Q4757555 3.10" 1.70" 0.04 lbs. 3.5 6.4 4.6 3.4 ProPEX EP Reducing Tee, '/<" PEX x'/z' PEX x'/;' PEX* Q4757557 3.10" 1.94" 0.04 lbs. 2.3 16.1 5.4 5.4 ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x PEX Q4757563 3.30" 1.85" 0.05 lbs. N/A N/A N/A N/A ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x'/z' PEX* Q4757550 3.30" 1.70" 0.04 lbs. 2.0 7.6 14.2 3.1 ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x 1" PEX* Q4757710 3.64" 2.32" 0.08 lbs. 1.5 5.7 15.7 8.7 ProPEX EP Reducing Tee, 1" PEX x'/i' PEX x 1" PEX Q4751501 3.71" 2.43" 0.09 lbs. 1.98 9.7 12.3 5.7 ProPEX EP Reducing Tee, 1" PEX x'/d' PEX x'/ PEX Q4751750 3.65" 1.96" 0.07 lbs. 2.27 6.69 3.1 13.2 ProPEX EP Reducing Tee, 1" PEX x'/<" PEX x'/4" PEX* Q4751775 3.90" 2.24" 0.08 lbs. 2.4 16.7 12.8 5.3 ProPEX EP Reducing Tee, 1" PEX x'/<" PEX x 1" PEX* Q4751751 3.90" 2.47" 0.08 lbs. 2.4 15.1 12.9 10.5 ProPEX EP Reducing Tee, 1" PEX x'/;' PEX x 1%" PEX Q4751753 4.15" 2.95" 0.12 lbs. 2.74 19.48 14.7 12.0 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x'/;' PEX* Q4751150 4.10" 2.00" 0.08 lbs. 1.2 6.5 32.2 3.4 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x %" PEX* Q4751175 4.10" 2.24" 0.09 lbs. 1.7 6.4 27.8 8.2 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1 '/;' PEX* Q4751113 4.38" 2.95" 0.13 lbs. 6.52 5.37 15.0 28.0 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x'/<" PEX* Q4751377 4.11" 2.38" 0.09 lbs. 2.74 7.41 7.3 12.0 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x 1" PEX* Q4751371 4.37" 2.62" 0.11 lbs. 2.70 7.59 13.9 12.1 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x 1Y<" PEX* Q4751373 4.61" 2.88" 0.13 lbs. 2.74 11.91 18.8 12.0 ProPEX EP Reducing Tee, 1'/<" PEX x 1" PEX x %" PEX* Q4751317 4.50" 2.73" 0.11 lbs. 3.4 5.2 21.0 9.3 ProPEX EP Reducing Tee, 11/;' PEX x 1" PEX x 1" PEX* Q4751311 4.70" 2.97" 0.12 lbs. 11.0 23.0 11.7 8.4 ProPEX EP Reducing Tee, 11/;' PEX x 11/4" PEX x'/;' PEX* Q4751350 4.40" 2.15" 0.10 lbs. 1.9 3.9 45.2 4.1 ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x %" PEX* Q4751337 4.70" 2.73" 0.13 lbs. 2.3 5.7 43.4 8.9 ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x 1" PEX* Q4751331 5.00" 2.97" 0.14 lbs. 4.2 6.3 33.0 15.8 ProPEX EP Reducing Tee, 1'/z" PEX x'/<" PEX x %" PEX Q4751577 4.37" 2.64" 0.13 lbs. 2.88 7.41 7.3 11.7 ProPEX EP Reducing Tee, 1'/z" PEX x'/<" PEX x 1'/z" PEX Q4751575 4.97" 3.39" 0.19 lbs. 2.74 19.10 22.9 12.0 ProPEX EP Reducing Tee, 1'/z" PEX x 1" PEX x %" PEX Q4751517 5.25" 3.06" 0.17 lbs. 4.0 5.1 19.5 9.3 ProPEX EP Reducing Tee, 1'/z" PEX x 1" PEX x 1" PEX Q4751511 5.25" 3.30" 0.18 lbs. 4.3 6.5 18.9 15.6 ProPEX EP Reducing Tee, 11/2" PEX x 1" PEX x 11/2" PEX Q4751505 5.40" 3.45" 0.20 lbs. 4.2 14.9 19.0 26.5 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x %" PEX Q4751537 5.50" 2.65" 0.18 lbs. 4.2 11.3 33.1 6.3 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 1" PEX Q4751531 5.50" 2.85" 0.19 lbs. 3.1 13.1 36.4 11.2 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 11/4" PEX Q4751533 5.50" 3.15" 0.21 lbs. 2.0 17.7 45.4 17.0 ProPEX EP Reducing Tee, 1'/z" PEX x 1'/2" PEX x'/i' PEX Q4751550 4.95" 2.30" 0.14 lbs. 2.4 6.3 60.5 3.4 ProPEX EP Reducing Tee, 1'/z" PEX x 1'/2" PEX x %" PEX Q4751557 5.30" 3.06" 0.20 lbs. 2.9 5.4 56.0 9.0 ProPEX EP Reducing Tee, 1'/2" PEX x 1'/2" PEX x 1" PEX Q4751551 5.75" 3.30" 0.21 lbs. 3.1 6.9 53.8 15.3 ProPEX EP Reducing Tee, 1'/2" PEX x 1'/2" PEX x 11/4" PEX Q4751553 5.80" 3.56" 0.22 lbs. 3.2 4.1 54.3 33.7 Installation Use the appropriate ProPEX ring for PEX-a pipe. Refer to the Uponor Piping Systems Installation Guide, the AquaSAFETm Residential Fire Sprinkler Installation Guide or the Uponor Radiant Installation Handbook for additional information. Standards Codes Listings ASTM E84; ASTM E119; ASTM E814; IBC; IMC; IPC; IRC; NPC of Canada; cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ASTM F877; ASTM F1960; NSPC; UMC; UPC ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code CAN/CSA B137.5; NSF 14; NSF 61 Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 1481h Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFETM fire safety systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor Inc. ProPEX" is a trademark of Uponor Ltd. ProPEX® Engineered Polymer (EP) Elbow Submittal information Revision J: June 21, 2019 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: ADDroved bv: Technical data Material: Engineered polymer (EP) Maximum temperature (no pressure): 320°F (160°C) Maximum working temperature/pressure: 210°F (99°C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) elbows make 90-degree connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire safety and hydronic radiant heating and cooling systems. Each end of the elbow is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXTm tubing.' Uponof ✓ Description Part number A B Weight Equivalent Cv length (ft.) ProPEX EP Elbow, '/z" PEX x'/z" PEX Q4760500 1.30" 1.30" 0.02 lbs. 10.4 2.6 ProPEX EP Elbow, 3/4° PEX x 3/4" PEX* Q4760750 1.60" 1.60" 0.03 lbs. 10.8 6.7 ProPEX EP Elbow, 1" PEX x 1" PEX* Q4761000 2.10" 2.10" 0.07 lbs. 11.5 11.9 ProPEX EP Elbow, 1'/4" PEX x 1'/4" PEX* Q4761250 2.45" 2.45" 0.11 lbs. 10.0 22.2 ProPEX EP Elbow, 1'/z" PEX x 1'/z" PEX Q4761500 2.77" 2.77" 0.18 lbs. 11.5 29.7 ProPEX EP Elbow, 2" PEX x 2" PEX Q4762000 3.76" 3.76" 0.30 lbs. 17.1 50.2 ProPEX EP Elbow, 2'/z" PEX x 2'/z" PEX Q4762500 4.93" 4.93" 0.85 lbs. 20.0 86.0 ProPEX EP Elbow, 3" PEX x 3" PEX Q4763000 5.88" 5.88" 1.44 lbs. 23.2 125.0 ProPEX EP 45 Elbow, 1'/2' PEX x 1'/2" PEX Q4761515 2.32" 2.32" 0.13 lbs. 9.3 33.1 ProPEX EP 45 Elbow, 2" PEX x 2" PEX Q4762020 2.91" 2.91" 0.32 lbs. 8.8 68.9 ProPEX EP 45 Elbow, 2'/2' PEX x 2'/2" PEX Q4762525 3.83" 3.83" 0.65 lbs. 7.0 136.8 ProPEX EP 45 Elbow, 3" PEX x 3" PEX Q4763030 4.48" 4.48" 1.07 lbs. 8.3 195.5 Installation Use the appropriate ProPEX ring for PEX-a tubing. Refer to the Uponor Piping Pocket Guide, AquaSAFETm Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards ASTM E84; ASTM E119; ASTM E814; ASTM F877; ASTM F1960; CAN/CSA B137.5; NSF 14; NSF 61 Codes IBC; IMC; IPC; IRC; NPC of Canada; NSPC; UMC; UPC Listings cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 148t' Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFE fire safety systems uponorpro.com uponorpro.com 1 ProPEX® is a registered trademark of Uponor, Inc. ProPEX- is a trademark of Uponor Ltd. ProPEX° Fire Sprinkler Adapter Submittal Information Revision B: March 17, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: 300 Series Stainless Steel Product Information and Application Use Use the ProPEX° Fire Sprinkler Adapter in conjunction with the appropriate sprinkler to provide a multi -purpose residential fire sprinkler system'. For residential applications, the system is installed with the cold -potable portion of the Uponor plumbing system. Make connections with Uponor ProPEX fittings. These fittings are designed for use only with 3/4" or 1" AquaPEX° White tubing in the Uponor AQUASAFE° Looped System. uponof ✓ Description Part A B C D E Weight Number ProPEX Fire Sprinkler Adapter, 3/4" PEX x 1/2" FNPT Q7517550 0.75" 1.88" 2.50" 1.82" 1.41" 0.268 lbs. ProPEX Fire Sprinkler Adapter, 1" PEX x 1/2" FNPT Q7511050 0.75" 1.88" 2.50" 2.06" 1.54" 0.408 lbs. Installation Use appropriate ProPEX Ring for connecting the tubing. Refer to the AquaPEX Installation Handbook or the Uponor AQUASAFE° Installation Guide for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F 1960 Codes IPC; UPC; NSPC; IRC; IMC; NPC of Canada Listings ANSI/NSF 14- and 61-certified; U.P. Code; ICC ESR 1099; HUD MR 1269; UL 1821; ULC/ORD - C 199 P Related Applications PEX-a Plumbing Systems AQUASAFE Fire Safety Systems Contact Information Uponor, Inc. 5925 1481h Street West Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca 'ProPEX° is a registered trademark of Uponor, Inc. ProPEXTM is a trademark of Uponor Ltd. Bulletin 033 February 2019 Rellablia Model 171 RES LL Residential Sprinklers Specifically Listed for use in Multipurpose Systems that serve both domestic water and fire protection. Types: 1. F1 Res 30 LL Pendent 2, F1 Res 30 LL Recessed Pendent/F2 3, F1 Res 30 LL Recessed Pendent/FP 4. F1 Res 49 LL Pendent 5. F1 Res 49 LL Recessed Pendent/F1 6. F1 Res 49 LL Recessed Pendent/FP 7. F1 Res 58 LL Pendent 8. F1 Res 58 LL Recessed Pendent/F1 9. F1 Res 58 LL Recessed Pendent/FP 10. F1 Res 30 LL CCP Pendent 11. F1 Res 49 LL CCP Pendent 12. F1 Res 58 LL CCP Pendent 13. F1 Res 44 LL HSW 14. F1 Res 44 LL Recessed HSW/F2 15. F1 Res 58 LL HSW 16. F1 Res 58 LL HSW Recessed HSW/F2 17. F1 Res 44 LL SWC Pendent/F1, F1 Res 30 LL Recessed Pendent/F2 Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) for Safety to ANSI/ U L 1626. 2. Certified by Underwriters Laboratories, Inc. and Under- writers Laboratories of Canada for Health Effects to NSF/ ANSI Standard 61 Annex G (Less than 0.25% Lead Con- tent,) 3, WaterMark certified. WaterMark Certificate Number 23347 Additional Bulletins applicable to all F1 RES LL Sprinklers • Wall Wetting - Bulletin 007 • Design and Installation - Bulletin 140 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 LL & 58 LL Pendent Sprinklers Other patents pending. LL Recessed Pendent/FP 11 Pendent 11 CCP Pendent HSW Recessed HSW/F2 SWC Product Description Model F1 Res LL Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitivity glass -bulb and low profile decorative design. The F1 Res LL Horizontal Sidewall sprinklers (Figs. 5, & 6) are equally attractive when above ceiling piping cannot be used. The 3mm glass -bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in resi- dential fire protection design. The low flow F1 Res LL sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection application needs of the latest residential market standards (UL 1626 Standard). Upon fire conditions, rising heat causes a sprinkler's heat -sensitive glass -bulb to shatter, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass -bulb • Sprinkler Frame : Brass • Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: 1/2" NPT (R1/2) • K-Factor: 3.0 (Actual) - F1 Res 30 LL Pendent Sprinkler 4.9 (Actual) - F1 Res 49 LL Pendent Sprinkler 5.8 (Actual) - F1 Res 58 LL Pendent & HSW Sprinkler 4.4 (Actual) - F1 Res 44 LL HSW Sprinkler Cj m 0 W co CD 71 0 z. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Model F1 Res LL sprinklers are cULus Listed in accor- dance with UL 1626 for installation in accordance with NFPA 13, NFPA 13R, and NFPA 13D. Sprinkler systems using Model F1 Res LL sprinklers must be hydraulically designed to provide at least the flow identified in the Tech- nical Data tables in this bulletin. For NFPA 13 installations, the flow per sprinkler must be the greater of: (1) the flow listed in the applicable Technical Data table and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For cover- age area dimensions less than those listed in the Technical Data tables, use the minimum required flow for the next larger max. coverage area listed. • Model F1 Res 30 LL, 49 LL & 58 LL Pendent 135FG03 Fig. 1 Installation Models F1 Res LL sprinklers are to be installed as shown, Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Model F1 Res LL sprinklers, Use of any other recessed escutcheon will void all approvals and warranties. For installing Model F1 Res LL Pendent sprinklers use only the Model W2 sprin- kler Wrench; for installing Models F1 Res LL Recessed • Model F1 Res 30 LL Recessed Pendent / F2 • Model F1 Res 49 LL & 58 LL Recessed Pendent / F1 2 1/4" HDLE DIA. [51.2mm] 1 IS/I6" DIA. [49.2mm] f/ - 1"X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. I I FACE OF FITTING TO CEILING DIMENSION: TJT�/ 3/I6-15/16 (F1 ESCUTCHEON) 3/16-11/16 (F2 ESCUTCHEON) ADIUSTMENT ®��� I [3�2mmJ A" 135FGO2A 2 27/32" Du. [7z2mm] Pendent, CCP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for installing Model F1 LL Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install F1 Res 44 LL with a ceiling to de- flector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" marking must face ceiling. Fig. 2 Escutcheon*, F1 or F2, Data: Adjustment „A„ Face of fitting Type Inch (mm) Inch (mm) to ceiling Inch (mm) F1 3/4 (19.0) Min.=3/4" (19.1) 3/16 - 15/16 Max. =11/2" (38.1) (4.7 - 24.0) F2 1/2 (12.7) Min.=15/16" (23.8) 3/16 - 11/16 Max. =11/2" (38.1) (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 LL & 58 LL Recessed Pendent Sprinkler 2. Technical Data: F1 Res 30 LL Pendent and Recessed Pendent (SIN RA3311) Thread Size Nominal Orifice Inch mmpsi(bar) Max. Pressure Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch mm OF °C OF °C 1/2" NPT 21/64" (8.2) 175 (12) 155 68 100 38 3.0 (43.2) 2.25 (57) R1/z 175 79 Max. Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Spacing 155°F/68°C 175°F/79°C Top of Deflector to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Inch (mm) Ft (m) GPM (L/min) PSI(bar) GPM (L/min) PSI(bar) Ft (m) 12 x 12 (3.6 x 3.6) 12(3.6) 8(30.3) 7.0 (0.48) 8(30.3) 7.0 (0.48) Smooth Ceilings 1" to 4" (25mm to 100mm) Beamed Ceilings per NFPA 13, 13D, or 13R 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 10 (37.8) 11 (0.76) 10 (37.8) 11 (0.76) 16 x 16 (4.9 x 4.9) 16(4.9) 13 (49) 18.8 (1.3) 13 (49) 18.8 (1.3) Technical Data: F1 Res 49 LL Pendent and Recessed Pendent (SIN RA3316) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Tem . Ratin °F °C Ambient Temp. K Length OF °C psi bar 155 68 Factor Inch mm 1/2" NPT 7/16" (11) 175 (12) 100 38 4.9 (70.6) 2.25 (57) RYz 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 155°F/680C 175°F/790C to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) (mm) Ft (m) GPM min PSI a GPM min PSI(bar)Inch Smooth Ceilings 1" to 4" (25mm to 100mm) 8(2.4) 12 x 12 (3.6 x 3.6) 12(3.6) 13 (49) 7.0 (0.48) 13 (49) 7.0 (0.48) 14 x 14 (4.3 x 4.3) 14(4.3) 13 (49) 7.0 (0.48) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 16(4.9) 13 (49) 7.0 (0.48) 13 (49) 7.0 (0.48) Beamed Ceilings per NFPA 13, 13D, or 13R 18 x 18 (5.5 x 5.5) 18(5.5) 17 (64.3) 12 (0.83) 17 (64.3) 12 (0.83) 20 x 20 (6.1 x 6.1) 20(6.1) 20 (75.7) 16.7 (1.14) 20 (75.7) 16.7 (114) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 155°F/68°C(175'F/79'C) Intermediate Temp. Rating Top of Deflector to In Ceiling (mm) Minimum Spacing Ft (m) Flow GPM min Pressure PSI Flow GPM min Pressure PSI(badInch 12 x 12 (3.6 x 3.6) 12(3.6) 15 (57) 9.4 (0.65) 15 (57) 9.4 (0.65) Smooth Ceilings 4" to 8" (100mm to 200mm) 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 16 (60.5) 10.6 (0.73) 16 (60,5) 10.6 (0.73) 16 x 16 (4.9 x 4.9) 16(4.9) 17 (64.3) 12.0 (0.83) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5 x 5.5) 18(5.5) 19 (72) 15.0 (1.0) 19 (72) 15.0 (1.0) 20 x 20 (6.1 x 6.1) 20(6.1) 22 (83.2) 20.2 (1.4) 22 (83.2) 20.2 (1.4) 3. Technical Data: F1 Res 58 LL Pendent and Recessed Pendent (SIN RA3313) Thread Nominal Orifice Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) Pressure Temp. Ratin Ambient Temp. K Factor Length OF °C °F °C psi (bar) Inch (mm) 1/2" NPT 1/2" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.25 (57) (R1/2) 175 79 150 66 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing 155°F/680C 1750F/790C Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) In (mm) Ft (m) GPM min PSI a GPM Umin PSI(bar)Inch 12 x 12 (3.6 x 3.6) 12(3.6) 16 (61) 7.6 (0.53) 16 (61) 7.6 (0.53) Smooth Ceilings 1" to 4" (25mm to 100mm) 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 16 (61) 7.6 (0.53) 16 (61) 7.6 (0.53) 16 x 16 (4.9 x 4.9) 16(4.9) 16 (61) 7.6 (0.53) 16 (61) 7.6 (0.53) Beamed Ceilings per NFPA 13, 13D, or 13R 18 x 18 (5.5 x 5.5) 18(5.5) 19 (72) 10.8 (0.75) 19 (72) 10.8 (0,75) 20 x 20 (6.1 x 6.1) 20(6.1) 22 (83,3) 14.4 (1.0) 22 (83.3) 14.4 (1.0) • Model F1 Res 30 LL, 49 LL & 58 1 1 f! D 0--A-n+ 2 518" [66.7mml DIA. 2 5116" DIA. HOLE IN CEILING [58.7mm] CUP V 1 "x1/2" REDUCER CUP / CEILING 1 114» [31.5mm] WStltl MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION A» B' COVER ADJUSTMENT HEIGHT 3 5116» DIA. 135FG04D [84.1 mm] Fig. 3 • Model F1 Res 30 LL, 49 LL & 58 LL RP_CP_CCPrI PPnr1pnt / FP rr pusn-on/tnreaa-OTT escutcneon 2 5/8" DIA. [66.7mm] HOLE IN CEILING 2 5/16" DIA. [58.7mm] CUP / I � 1" X 1/2" REDUCER I 1 I I L J CEILING ®.iPV01 dd�� MM tltl 1 1/2" [38.1mm] MAX. FACE OF flTTING -- - TO FACE OF CEILING �� DIMENSION J_ 1/2" [13mm] MAX \ FP ADJUSTMENT A IJ5FG01A Fig. 4 4 Technical Data: F1 Res 30 LL CCP Pendent and Recessed Pendent/FP (SIN RA3311) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Tem . atin Ambient Temp. Factor Length °C OF oC Inch mm psi (bar)OF Inch mm 1/2" NPT (RI/2) "/64" (8.2) 175 (12) 135 57 100 38 3.0 (43.2) 2.25 (57) Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating 155°F/68°C Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Vmin) Pressure PSI bar 12 x 12 (3.6 x 3.6) 12(3.6) 8(30.3) 7.0 (0.48) Smooth Ceilings 1/2" to 1" (13mm to 25mm) using CCP or FP escutcheon 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 11 (37.8) 13.4 (0.92) Beamed Ceilings per NFPA 13, 13D, or 13R Technical Data: F1 Res 49 LL CCP Pendent and Recessed Pendent/FP (SIN RA3316) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. RatingAmbient Temp. Factor Length OF °C OF oC Inch (mm) psi (bar) Inch (mm) 1/2" NPT (R'/2 ) 7/16" (11) 175 (12) 135 57 100 38 4.9 (70.6) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum ea Max. Spacing (155°F/68°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ftr(m x m) Ft (m) Inch (mm) (m)g 12(3.6) GPM (Vmin) PSI (bar) Smooth Ceilings 1/2" to 1" (13mm to 25mm) using CCP or FP 8(2.4) 12 x 12 (3.6 x 3.6) 13 (49) 7.0 (0.48) 14 x 14 (4.3 x 4.3) 14(4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 16(4.9) 14 (53) 8.2 (0.56) escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 18 x 18 (5.5 x 5.5) 18(5.5) 18 (68.1) 13.5 (0.93) 20x20(6.1 x6.1) 20(6.1) 20(75.7) 16.7(1.14) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 58 LL CCP Pendent and Recessed Pendent/FP (SIN RA3313) Thread Nominal Max. CCP Assembly Max. K Sprinkler Size Orifice Pressure Temp. Ratin Ambient Temp. Factor Length OF °C OF OC Inch (mm) psi (bar) Inch (mm) 1/2" NPT (R'/2 ) 1/2" (13) 175 (12) 135 57 100 38 5.8 (83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155°F/68°C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) (m) GPM (Vmin PSI(bar)Ft 12 x 12 (3.6 x 3.6) 12(3.6) 16 (61) 7.6 (0.53) 14 x 14 (4.3 x 4.3) 14(4.3) 16(61) 7.6(0.53) Smooth Ceilings 1/2" to 1" 16 x 16 (4.9 x 4.9) 16(4.9) 16 (61) 7.6 (0.53) (13mm to 25mm) using CCP or FP escutcheon Beamed Ceilings per NFPA 13, 13D, or 13R 8(2.4) 18 x 18 (5.5 x 5.5) 18(5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6.1) 20(6.1) 22 (83.3) 14.4 (1.0) 5. rll�"� 1 FACE OF FITTING TO WALL DIMENSION 1 1/4 ` MIN. [31.8mm] 2 1/4" HOLE DIA. 1/8 'q" [57.2mm] CEILING TO [3.2mm] DEFLECTOR 1" X 1/2- REDUCER DIMENSION ro� Illi lip I �--r1 �� IIIIIIII 1 15/16" DIA. [49.2mm] hill IIIII 2 27/32" DIA. IIIII [72.2mm] _IlIV V TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. l� `\ 1/2- [13mm] IJ5FG06-D ADJUSTMENT • Model F1 Res 44 LL & 58 LL HSW (r _ � .' �. ice► Rom, � •�,, 1 • Model F1 Res 44 LL & 58 LL Recessed HSW/F2 escutcheon, 1 2" (13mm) adjustment Technical Data: F1 Res 44 LL HSW & HSW/F2 (SIN RA3331) Nominal Max. Sprinkler Max. Sprinkler Thread Orifice Pressure Temp. Rating Ambient K Length Size Inch (mm) psi (bar) Temp. Factor Inch (mm) of °C 1/2" NPT 3/8" (10) 175 (12) 155 68 100 38 4.4(63) 2.45 (62) (R/2) 175 79 150 66 Escutcheon. F2. Data: Face of T Type Adjustment to wetting ll Inch (mm) Inch (mm) F2 1/2 (1 3) 3/16 - 11/16 (4.7 - 17.4) Max. Coverage area Ft x Ft (m x m) Max. Spac- ing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate (175°F/79°C) Temp. Rating Top of Deflector to Ceiling Inch (mm) 4 to 6 (100 to 152) Minimum Spacing Ft (m) 8(2.4) Flow Pressure GPM (L/min) PSI (bar) Flow GPM (Umin) Pressure PSI (bar) 12 x 12 (3.6 x 3.6) 12(3.6) 12 (45.4) 7.5 (0.52) 12 (45.4) 7.5 (0.52) 14 x 14 (4.3 x 4.3) 14(4.3) 14 (53.0) 10.2 (0.71) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9 x 4,9) 16(4.9) 16 (60.6) 13.3 (0.92) 16 (60.6) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 16(4.9) 18 (68.1) 16.8 (0.53) 18 (68.1) 16.8 (0.53) 18 x 18 (5.5 x 5.5) 18(5.5) 19 (72.0) 18.7 (1.29) 19 (72.0) 18.7 (1.29) 16 x 20 (4.9 x 6.1) 16(4.9) 23 (87.1) 27.4 (1.89) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6 x 3.6) 12(3.6) 14 (53.0) 10.2 (0.71) 14 (53.0) 10.2 (0.71) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3) 14(4.3) 16 (60.6) 13.3 (0.92) 16 (60.6) 13.3 (0.92) 16 x 16 (4.9 x 4.9) 16(4.9) 17 (64.4) 15.0 (1.04) 17 (64.4) 15.0 (1.04) 16 x 18 (4.9 x 5.5) 16(4.9) 20 (75.7) 20.7 (1.43) 20 (75.7) 20.7 (1.43) 16 x 20 (4.9 x 6.1) 16(4.9) 23 (87.1) 27.4 (1.89) 23 (87.1) 27.4 (1.89) on Technical Data: F1 Res 58 LL HSW & HSW/F2 (SIN RA3333) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Inch (mm) psi (bar) Inch (mm) OF °C °F °C 1/2" NPT 1/2" (13) 175 (12) 155 68 100 38 5.8 (83.5) 2.45 (62) (R1/2) 175 79 150 66 Max. Coverage area Ft x Ft (m x m) 12 x 12 (3.6 x 3.6) Max. Spacing Ft (m) Ordinary Temp. 155°F/68°C Rating Intermediate 1750F/79°C Temp. Rating Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM min)VPSI(bar)--GPM Pressure Flow Vmin Pressure PSI ar 12(3.6) 16 (60.6) 7.6 (0.53) 16 (60.6) 7.6 (0.53) 4 to 6 (100 to 152) 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 18 (68.2) 9.7 (0.69) 18 (68.2) 9.7 (0.69) 16 x 16 (4.9 x 4.9) 16(4.9) 21 (79.5) 13.2 (0.91) 21 (79.5) 13.2 (0.91) 16 x 18 (4.9 x 5.5) 16(4.9) 25 (94.7) 18.6 (1.28) 25 (94.7) 18.6 (1.28) 16 x 20 (4.9 x 6.1) 16(4.9) 29 (109.8) 25.0 (1.73) 29 (109.8) 25.0 (1.73) 12 x 12 (3.6 x 3.6) 12(3.6) 22 (83.3) 14.4 (1.0) 22 (83.3) 14.4 (1.0) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3) 14(4.3) 22 (83.3) 14.4 (1.0) 22 (83.3) 14.4 (1.0) 16 x 16 (4.9 x 4.9) 16(4.9) 26 (98.4) 20.1 (1.39) 26 (98.4) 20.1 (1.39) 16 x 18 (4.9 x 5.5) 16(4.9) 31 (117.4) 28.6 (1.97) 31 (117.4) 28.6 (1.97) • Model F1 Res 44 LL SWC Technical Data: F1 Res 44 LL SWC SIN RA3331 4" to 12" [101.60mm To 304.80mm] 1 1/4" [31.75mm] Maximum Face Of Fitting To Wall Dimension PUSH ON COVER, THEN TURN TO ADJUST UNTIL TIGHT AGAINST WALL. I" X 1/2" Reducer id Recommended Well Hole 2 5/8" 2 5/16" [58.74mm]�-tiii - - - - -- [66.68mm] Dig. 3 5/16" Dig. L ignL , [84.14mm] / Dio. -- _ TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER 1 21/32 WRENCH BOSS. [42. 07mm] IJ5FG07 1/2" [12.70mm] Adjustment Fig. 6 Nominal Max. Cover Max. Sprinkler Thread Orifice Pressure Temp. Ambient K Length Size inch (mm) psi (bar) Rating Temp. Factor Inch (mm) OF °C OF °C 1/2" NPT (R1/2) a „ /s (10) 175 (12) 135 57 100 38 4.4(63) 2.45 (62) 7. Technical Data: F1 Res 44 LL SWC (SIN RA3331) continued Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating 155°F/68°C Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (Vmin) Pressure PSI bar 12 x 12 (3.6 x 3.6) 12(3.6) 13 (49.2) 8.7 (0.60) 4 to 6 (100 to 152) 8(2.4) 14 x 14 (4.3 x 4.3) 14(4.3) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9 x 4.9) 16(4.9) 17(64.3) 15.0(1.1) 16 x 18 (4.9 x 5.5) 16(4.9) 19 (71.8) 18.7 (1.13) 16 x 20 (4.9 x 6.1) 16(4.9) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6 x 3.6) 12(3.6) 14 (52.9) 10.2 (0.71) 6 to 12 (152 to 305) 14 x 14 (4.3 x 4.3) 14(4.3) 15 (56.7) 11.7 (0.81) 16 x 16 (4.9 x 4.9) 16(4.9) 18(68.1) 16.8(1.16) 16 x 18 (4.9 x 5.5) 16(4.9) 20 (75.6) 20.7 (1.43) Maintenance Model F1 Res 30 LL, 49 LL, F1 Res 58 LL and F1 Res 44 LL Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Model F1 Res 30 LL, 49 LL & 58 LL Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Resi- dential sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Deflector -to -ceiling distance listing shall be 1" to 4" maximum, unless specifically listed other- wise. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a PTFE-coated Belleville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard fin- ish; [Bronze] [Chrome -plated] [White Polyester] [Special finish- specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 49 LL & 58 LL Recessed Pendent/F1 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2 Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer's installation guidelines and the applicable installation standard. Deflector -to -ceil- ing distance listing shall be 1" to 4" maximum, unless spe- cifically listed otherwise. Sprinkler frame and deflector shall be of bronze frame construction having a'/2" NPT thread. Water seal assembly shall consist of a PTFE-coated Bel- leville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)], Sprinklers shall have a nominal K-factor of 3.0, 4.9 & 5.8. Standard finish; [Bronze] [Chrome -plated] [White Polyester] [Special finish- specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with'/2" adjustment (Model F2)] [with 3/4" adjustment (Model F1)] [of push -on and thread off design with'/2" adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F1 ] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/F2] [Model F1 Res 30 LL, 49 LL & 58 LL Recessed Pendent/FP] SIN RA3311, RA3316 & RA3313 (Bulletin 033), A., Model F1 Res 30 LL, 49 LL & 58 LL CCP Pendent (Concealed) Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential concealed sprinklers engi- neered to provide a minimum design density of 0.05 gpm/ ft2 over the listed coverage area. Listed flows as speci- fied by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in confor- mance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a PTFE- coated Belleville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of 1550F (680C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push -on and thread -off design allowing a 1/2" cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C), A plastic protective cap shall be provided and factory in- stalled inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed, Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 30 LL, 49 LL & 58 LL CCP, SIN RA3311, RA3316 & RA3313 (Bulletin 033). Model F1 Res 44 LL Horizontal Sidewall Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] [WaterMark Certified WMCS] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in confor- mance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal assembly shall consist of a PTFE- coated Belleville spring washer with top -loaded extruded or cold head cup with 3 mm glass bulb containing no plas- tic parts, and having a temperature rating of [ 1550F (680C)] [175°F (790C)], Sprinklers shall have a nominal K-factor of 4.4 (62,8). Standard finish: [Bronze] [Chrome -plated] [White Polyester] [Special finish— specify]. Residential hori- zontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL, SIN RA3331 (Bulletin 033). Model F1 Res 44 LL Recessed Horizontal Sidewall Sprinkler Specifications Use description for the Model F1 Res 44 horizontal side - wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with 1/2" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish— specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 44 LL/F2, SIN RA3331 (Bulletin 033). Standard Finishes F1, F2, FP Sprinkler Cover Plates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black Polyester White Painted Coated Special Application Finishes F1, F2, Sprinkler Cover Plates Escutcheons Bright Brass Bright Brass Bright Brass Black Plated Black Plated Black Plated Black Paint Black Paint Black Paint Off White Off White Off White Satin Chrome Satin Chrome Satin Chrome (1) Other finishes and colors are available on special order. Consult factory for details. Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 6. Cover Plate Finish The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. J011111 Recycled ® (800) 431-1588 Sales Offices Paper Relle labi (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 02/19 P/N 9999970411 UponorAquaPEX®White, coils Submittal information Revision M: Sept. 18, 2018 Project information Job name: Location: Part no. ordered: Uponof Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Crosslinked polyethylene PEX-a Engel Method; PEX 5106 Standard grade hydrostatic ratings (PPI): 200°F (93°C) at 80 psi (551 kPa) 180°F (82°C) at 100 psi (689 kPa) 73.4°F (23°C) at 160 psi (1,103 kPa) '/2", %", 1", 1'/4", 1'/2" and 2" UponorAquaPEX® White only: --- 120°F (49°C) at 130 psi (896 kPa) Linear expansion rate: 1.1'/10°F/100' (27.94mm/5.56°C/30.48m) Product information and application use Uponor AquaPEX White is used for hot and cold domestic potable water distribution and residential fire safety as well as radiant heating/cooling and hydronic piping systems containing no ferrous corrodible components or where ferrous components are isolated from the piping. ✓ Description Part number I.D. O.D. Weight '/4' Uponor AquaPEX White, 100-ft. coil F1040250 0.241" 0.375" 4.0 lbs. Uponor AquaPEX White, 400-ft. coil F1090375 0.350" 0.500" 20.0 lbs. Uponor AquaPEX White, 1,000-ft. coil F1120375 0.350" 0.500" 44.0 lbs. ''/2" Uponor AquaPEX White, 100-ft. coil F1040500 0.475" 0.625" 6.0 lbs. %" Uponor AquaPEX White, 300-ft. coil F1060500 0.475" 0.625" 18.0 lbs. ''/z" Uponor AquaPEX White, 500-ft. coil F1100500 0.475" 0.625" 27.6 lbs. ''/z" Uponor AquaPEX White, 1,000-ft. coil F1120500 0.475" 0.625" 54.0 lbs. Uponor AquaPEX White, 300-ft. coil F1060625 0.574" 0.750" 28.0 lbs. Uponor AquaPEX White, 1000-ft. coil F1120625 0.574" 0.750" 86.0 lbs. Uponor AquaPEX White, 100-ft. coil F1040750 0.671" 0.875" 10.0 lbs. Y44" Uponor AquaPEX White, 300-ft. coil F1060750 0.671" 0.875" 34.0 lbs. %" Uponor AquaPEX White, 500-ft. coil F1100750 0.671" 0.875" 54.0 lbs. 1" Uponor AquaPEX White, 100-ft. coil F1041000 0.862" 1.125" 20.0 lbs. 1" Uponor AquaPEX White, 300-ft. coil F1061000 0.862" 1.125" 56.0 lbs. 1" Uponor AquaPEX White, 500-ft. coil F1101000 0.862" 1.125" 93.0 lbs. 1'/4' Uponor AquaPEX White, 100-ft. coil F1061250 1.054" 1.375" 34.0 lbs. 1'/4" Uponor AquaPEX White, 300-ft. coil F1021250 1.054" 1.375" 106.0 lbs. 1'/z" Uponor AquaPEX White, 100-ft. coil F1061500 1.244" 1.625" 44.0 lbs. 1'/z" Uponor AquaPEX White, 300-ft. coil F1021500 1.244" 1.625" 133.0 lbs. 2" Uponor AquaPEX White, 100-ft. coil F1062000 1.629" 2.125" 68.2 lbs. 2" Uponor AquaPEX White, 200-ft. coil F1052000 1.629" 2.125" 136.4 lbs. 2" Uponor AquaPEX White, 300-fit. coil F1022000 1.629" 2.125" 204.6 lbs. 2'/i' Uponor AquaPEX White, 100-ft. coil F1062500 2.011" 2.625" 88.0 lbs. 2'/i' Uponor AquaPEX White, 300-ft. coil F1022500 2.011" 2.625" 264.0 lbs. 3" Uponor AquaPEX White, 100-ft. coil F1063000 2.400" 3.125" 128.0 lbs. 3" Uponor AquaPEX White, 300-ft. coil F1023000 2.400" 3.125" 384.0 lbs. Installation Use ProPEX® fittings for %" through 3" pipe.' Refer to the ProPEX Connections Instructional Guide, Uponor Piping Pocket Guide, Plumbing Design Assistance Manual (PDAM), Complete Design Assistance Manual (CDAM), Hydronic Piping Design Assistance Manual (HPDAM) or AquaSAFET1A Residential Fire Sprinkler Installation Guide for more information. Listings2 Codes Standards cNSFus-fs3; cNSFus-pw; cQAlus P321; UL; IAPMO; ICC; IPC; IMC; IRC; ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM CSA; PPI TR-4; ICC-ES; BMEC; CCMC UPC; UMC; NSPC; HUD; F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; UFGS; NPC of Canada; ASTM E814/ULC S115; CSA B137.5; CSA B214; NBC of Canada UL 18213; ULC/ORD-C199P3; AWWA C9044 Related applications Contact information PEX-a plumbing systems Uponor, Inc. Uponor Ltd. AquaSAFETM fire safety systems 5925 148"' Street West 6510 Kennedy Road Radiant heating and cooling systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Hydronic piping systems Phone: 800.321.4739 Phone: 888.994.7726 Fax: 952.891.2008 Fax: 800.638.9517 uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEX- is a trademark of Uponor Ltd. 2Visit listing agency's website for complete information. 3For 3/4", 1" and 1'W pipe only. 4For %" to 3" pipe. ProPEX° Ring Submittal information Revision I: Nov. 1, 2018 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Engel -method crosslinked polyethylene (PEX-a) Density: 926 to 940 kg/m3 Degree of crosslinking: 70% to 89% Product information and application use Uponor ProPEX® rings are required to make a proper ProPEX connection.' The ProPEX ring with stop includes a leading edge chamfer and stop edge. ✓ Description Part number ProPEX Ring, %" ProPEX Ring with Stop, '/2" ProPEX Ring with Stop, %" ProPEX Ring with Stop, 3/4" ProPEX Ring with Stop, 1" ProPEX Ring with Stop, 1'/4" ProPEX Ring with Stop, 1'/2" ProPEX Ring with Stop, 2" ProPEX Ring with Stop, 2'/2" ProPEX Ring with Stop, 3" Installation Q4690302 Q4690512 Q4690625 Q4690756 Q4691000 Q4691250 Q4691500 Q4692000 Q4692500 Q4693000 uponof Length I.D. O.D. Weight 0.54" 0.49" 0.74" 0.005lbs. 0.63" 0.63" 0.87" 0.006lbs. 0.79" 0.75" 1.00" 0.008lbs. 0.87" 0.88" 1.13" 0.012lbs. 1.10" 1.13" 1.42" 0.020lbs. 1.35" 1.38" 1.66" 0.030lbs. 1.61" 1.63" 1.91" 0.040 lbs. 1.97" 2.14" 2.61" 0.133lbs. 2.61" 2.66" 3.25" 0.230lbs. 3.12" 3.16" 3.87" 0.400lbs. Square cut the Uponor PEX tubing. Remove excess material. Slide the ProPEX ring over the end of the tubing (maximum 'lid' over -hang for rings without stop). When using the ProPEX ring with stop, slide the ring on the tubing with the chamfered edge first until the end of the tubing contacts the stop edge. Expand the tubing and ring. If using the ProPEX Manual Expander Tool, rotate the tool a quarter turn after each expansion to prevent the formation of grooves. Remove the expansion tool and fully seat the tubing and ring against the shoulder of the fitting. Make ProPEX connections at temperatures above 5°F/-15°C. For more information, refer to the Uponor ProPEX Connections Instructional Guide. Listings' cNSFus-fs3; cNSFus-pw; cNSFus-rfh; cQAlus; UL; CSA; PPI TR-4; ICC-ES; IAPMO; BMEC; CCMC; cQAlus P321 Codes ICC; IPC; IMC; IRC; UPC; UMC; NSPC; HUD; UFGS; NPC of Canada; NBC of Canada Standards ANSI/NSF 14; ANSI/NSF 61; ASTM F876; ASTM F877; ASTM F1960; ASTM F2023; ASTM E84; CAN/ULC S102.2; ASTM E119/UL 263; CAN/ULC S101; ASTM E814/ULC S115; CSA 13137.5; CSA B214; UL 18213; ULC/ORD-C199P3 Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. AquaSAFE fire safety systems 5925 148"' Street West 6510 Kennedy Road Hydronic radiant heating and cooling systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Snow melting systems Phone: 800.321.4739 Phone: 888.994.7726 Turf conditioning systems Fax: 952.891.2008 Fax: 800.638.9517 Permafrost prevention systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEXT" is a trademark of Uponor Ltd. 2Visit listing agency's website for complete information; 3For '/2",'/", 1", 11/", 1'/2" and 2" tubing only ProPEXO Engineered Submittal information Revision H: May 23, 2019 Project information Job name: Polymer (EP) Tee Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved bv: Technical data Material: Engineered polymer (EP) Maximum temperature (no pressure): 320°F (160°C) Maximum working temperature/pressure: 210*F (99*C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) tees make diverting connections for Uponor crosslinked polyethylene (PEX-a)tubing for use in hot and cold domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXTM tubing.' Note: Branch size is listed last in the part descriptions. Uponof Part ✓ Equivalent Equivalent cv cv Description number A B Weight length (ft.) length (ft.) through branch through branch ProPEX EP Tee, ''M." PEX x'/z' PEX x'/" PEX Q4755060 2.50" 1.53" 0.02 lbs. 1.0 6.3 7.7 3.4 ProPEX EP Tee, %" PEX x'/:' PEX x'/:' PEX* Q4757575 3.30" 1.94" 0.05 lbs. 1.5 15.6 15.7 5.4 ProPEX EP Tee, 1" PEX x 1" PEX x 1" PEX* Q4751010 4.10" 2.47" 0.07 lbs. 1.3 12.7 30.5 11.3 ProPEX EP Tee, 1'/4" PEX x 1'/4" PEX x 1'/4" PEX* Q4751313 4.80" 3.22" 0.15 lbs. 3.8 8.6 34.0 23.9 ProPEX EP Tee, 1 Yz' PEX x 1'/." PEX x 1'M." PEX Q4751515 5.80" 3.82" 0.25 lbs. 1.8 10.6 63.7 31.0 ProPEX EP Tee, 2" PEX x 2" PEX x 2" PEX Q4752000 7.45" 4.79" 0.38 lbs. 0.8 15.5 150.7 52.5 ProPEX EP Tee, 21/' PEX x 21/z' PEX x 21/z' PEX Q4752500 10.56" 5.45" 1.14 lbs. 2.7 22.3 197.2 81.5 ProPEX EP Tee, 3" PEX x 3" PEX x 3" PEX Q4753000 12.26" 6.37" 1.86 lbs. 2.8 23.9 286.6 122.8 Installation Use the appropriate ProPEX Ring for PEX-a tubing. Refer to the Uponor Professional Plumbing Installation Guide, AquaSAFET"^ Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards ASTM E84; ASTM E119; ASTM E814; ASTM F877; ASTM F1960; CAN/CSA B137.5; NSF 14; NSF 61 Codes IBC; IMC; IPC; IRC; NPC of Canada; NSPC; UMC; UPC Listings cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information PEX-a plumbing systems Uponor, Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 148t' Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFETm fire safety systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor, Inc. ProPEXT" is a trademark of Uponor Ltd. ProPEX° Engineered Polymer (EP) Reducing Tee (up to 11/2") uponof Submittal information Revision I: Sept. 16, 2019 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: Approved by: Technical data Material: Engineered polymer (EP) n� Maximum temperature (no pressure): 320°F (160°C) Max. working temperature/pressure: 210°F (99°C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) reducing tees make diverting connections for Uponor PEX-a pipe for use in hot and cold B domestic potable water systems, residential fire sprinkler systems and hydronic radiant heating and cooling systems. Each end of the tee is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX11 or Wirsbo hePEXTM pipe.' Note: Branch size is listed last in the part descriptions. ✓ Description Part A B Weight Equiv, length (ft.) Equiv. length Cv Cv number through (ft.) branch through branch ProPEX EP Reducing Tee,''/2" PEX x'/i' PEX x %" PEX Q4755575 2.86" 1.76" 0.03 lbs. 1.0 15.6 7.7 5.4 ProPEX EP Reducing Tee, '/<" PEX x'/i' PEX x'/i' PEX Q4757555 3.10" 1.70" 0.04 lbs. 3.5 6.4 4.6 3.4 ProPEX EP Reducing Tee, '/<" PEX x'/z' PEX x'/;' PEX* Q4757557 3.10" 1.94" 0.04 lbs. 2.3 16.1 5.4 5.4 ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x PEX Q4757563 3.30" 1.85" 0.05 lbs. N/A N/A N/A N/A ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x'/z' PEX* Q4757550 3.30" 1.70" 0.04 lbs. 2.0 7.6 14.2 3.1 ProPEX EP Reducing Tee, '/<" PEX x'/;' PEX x 1" PEX* Q4757710 3.64" 2.32" 0.08 lbs. 1.5 5.7 15.7 8.7 ProPEX EP Reducing Tee, 1" PEX x'/i' PEX x 1" PEX Q4751501 3.71" 2.43" 0.09 lbs. 1.98 9.7 12.3 5.7 ProPEX EP Reducing Tee, 1" PEX x'/d' PEX x'/ PEX Q4751750 3.65" 1.96" 0.07 lbs. 2.27 6.69 3.1 13.2 ProPEX EP Reducing Tee, 1" PEX x'/<" PEX x'/4" PEX* Q4751775 3.90" 2.24" 0.08 lbs. 2.4 16.7 12.8 5.3 ProPEX EP Reducing Tee, 1" PEX x'/<" PEX x 1" PEX* Q4751751 3.90" 2.47" 0.08 lbs. 2.4 15.1 12.9 10.5 ProPEX EP Reducing Tee, 1" PEX x'/;' PEX x 1%" PEX Q4751753 4.15" 2.95" 0.12 lbs. 2.74 19.48 14.7 12.0 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x'/;' PEX* Q4751150 4.10" 2.00" 0.08 lbs. 1.2 6.5 32.2 3.4 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x %" PEX* Q4751175 4.10" 2.24" 0.09 lbs. 1.7 6.4 27.8 8.2 ProPEX EP Reducing Tee, 1" PEX x 1" PEX x 1 '/;' PEX* Q4751113 4.38" 2.95" 0.13 lbs. 6.52 5.37 15.0 28.0 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x'/<" PEX* Q4751377 4.11" 2.38" 0.09 lbs. 2.74 7.41 7.3 12.0 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x 1" PEX* Q4751371 4.37" 2.62" 0.11 lbs. 2.70 7.59 13.9 12.1 ProPEX EP Reducing Tee, 1%" PEX x'/<" PEX x 1Y<" PEX* Q4751373 4.61" 2.88" 0.13 lbs. 2.74 11.91 18.8 12.0 ProPEX EP Reducing Tee, 1'/<" PEX x 1" PEX x %" PEX* Q4751317 4.50" 2.73" 0.11 lbs. 3.4 5.2 21.0 9.3 ProPEX EP Reducing Tee, 11/;' PEX x 1" PEX x 1" PEX* Q4751311 4.70" 2.97" 0.12 lbs. 11.0 23.0 11.7 8.4 ProPEX EP Reducing Tee, 11/;' PEX x 11/4" PEX x'/;' PEX* Q4751350 4.40" 2.15" 0.10 lbs. 1.9 3.9 45.2 4.1 ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x %" PEX* Q4751337 4.70" 2.73" 0.13 lbs. 2.3 5.7 43.4 8.9 ProPEX EP Reducing Tee, 11/4" PEX x 11/4" PEX x 1" PEX* Q4751331 5.00" 2.97" 0.14 lbs. 4.2 6.3 33.0 15.8 ProPEX EP Reducing Tee, 1'/z" PEX x'/<" PEX x %" PEX Q4751577 4.37" 2.64" 0.13 lbs. 2.88 7.41 7.3 11.7 ProPEX EP Reducing Tee, 1'/z" PEX x'/<" PEX x 1'/z" PEX Q4751575 4.97" 3.39" 0.19 lbs. 2.74 19.10 22.9 12.0 ProPEX EP Reducing Tee, 1'/z" PEX x 1" PEX x %" PEX Q4751517 5.25" 3.06" 0.17 lbs. 4.0 5.1 19.5 9.3 ProPEX EP Reducing Tee, 1'/z" PEX x 1" PEX x 1" PEX Q4751511 5.25" 3.30" 0.18 lbs. 4.3 6.5 18.9 15.6 ProPEX EP Reducing Tee, 11/2" PEX x 1" PEX x 11/2" PEX Q4751505 5.40" 3.45" 0.20 lbs. 4.2 14.9 19.0 26.5 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x %" PEX Q4751537 5.50" 2.65" 0.18 lbs. 4.2 11.3 33.1 6.3 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 1" PEX Q4751531 5.50" 2.85" 0.19 lbs. 3.1 13.1 36.4 11.2 ProPEX EP Reducing Tee, 11/2" PEX x 11/4" PEX x 11/4" PEX Q4751533 5.50" 3.15" 0.21 lbs. 2.0 17.7 45.4 17.0 ProPEX EP Reducing Tee, 1'/z" PEX x 1'/2" PEX x'/i' PEX Q4751550 4.95" 2.30" 0.14 lbs. 2.4 6.3 60.5 3.4 ProPEX EP Reducing Tee, 1'/z" PEX x 1'/2" PEX x %" PEX Q4751557 5.30" 3.06" 0.20 lbs. 2.9 5.4 56.0 9.0 ProPEX EP Reducing Tee, 1'/2" PEX x 1'/2" PEX x 1" PEX Q4751551 5.75" 3.30" 0.21 lbs. 3.1 6.9 53.8 15.3 ProPEX EP Reducing Tee, 1'/2" PEX x 1'/2" PEX x 11/4" PEX Q4751553 5.80" 3.56" 0.22 lbs. 3.2 4.1 54.3 33.7 Installation Use the appropriate ProPEX ring for PEX-a pipe. Refer to the Uponor Piping Systems Installation Guide, the AquaSAFETm Residential Fire Sprinkler Installation Guide or the Uponor Radiant Installation Handbook for additional information. Standards Codes Listings ASTM E84; ASTM E119; ASTM E814; IBC; IMC; IPC; IRC; NPC of Canada; cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ASTM F877; ASTM F1960; NSPC; UMC; UPC ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code CAN/CSA B137.5; NSF 14; NSF 61 Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 1481h Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFETM fire safety systems uponorpro.com uponorpro.com 'ProPEX® is a registered trademark of Uponor Inc. ProPEX" is a trademark of Uponor Ltd. ProPEX® Engineered Polymer (EP) Elbow Submittal information Revision J: June 21, 2019 Project information Job name: Location: Part no. ordered: Engineer: Date submitted: Contractor: Submitted by: Manufacturer's representative: ADDroved bv: Technical data Material: Engineered polymer (EP) Maximum temperature (no pressure): 320°F (160°C) Maximum working temperature/pressure: 210°F (99°C) at 150 psi (1,034 kPa) Product information and application use ProPEX® engineered polymer (EP) elbows make 90-degree connections for Uponor crosslinked polyethylene (PEX-a) tubing for use in hot and cold domestic potable water systems, residential fire safety and hydronic radiant heating and cooling systems. Each end of the elbow is manufactured with an Uponor ProPEX fitting for connections to Uponor AquaPEX® or Wirsbo hePEXTm tubing.' Uponof ✓ Description Part number A B Weight Equivalent Cv length (ft.) ProPEX EP Elbow, '/z" PEX x'/z" PEX Q4760500 1.30" 1.30" 0.02 lbs. 10.4 2.6 ProPEX EP Elbow, 3/4° PEX x 3/4" PEX* Q4760750 1.60" 1.60" 0.03 lbs. 10.8 6.7 ProPEX EP Elbow, 1" PEX x 1" PEX* Q4761000 2.10" 2.10" 0.07 lbs. 11.5 11.9 ProPEX EP Elbow, 1'/4" PEX x 1'/4" PEX* Q4761250 2.45" 2.45" 0.11 lbs. 10.0 22.2 ProPEX EP Elbow, 1'/z" PEX x 1'/z" PEX Q4761500 2.77" 2.77" 0.18 lbs. 11.5 29.7 ProPEX EP Elbow, 2" PEX x 2" PEX Q4762000 3.76" 3.76" 0.30 lbs. 17.1 50.2 ProPEX EP Elbow, 2'/z" PEX x 2'/z" PEX Q4762500 4.93" 4.93" 0.85 lbs. 20.0 86.0 ProPEX EP Elbow, 3" PEX x 3" PEX Q4763000 5.88" 5.88" 1.44 lbs. 23.2 125.0 ProPEX EP 45 Elbow, 1'/2' PEX x 1'/2" PEX Q4761515 2.32" 2.32" 0.13 lbs. 9.3 33.1 ProPEX EP 45 Elbow, 2" PEX x 2" PEX Q4762020 2.91" 2.91" 0.32 lbs. 8.8 68.9 ProPEX EP 45 Elbow, 2'/2' PEX x 2'/2" PEX Q4762525 3.83" 3.83" 0.65 lbs. 7.0 136.8 ProPEX EP 45 Elbow, 3" PEX x 3" PEX Q4763030 4.48" 4.48" 1.07 lbs. 8.3 195.5 Installation Use the appropriate ProPEX ring for PEX-a tubing. Refer to the Uponor Piping Pocket Guide, AquaSAFETm Residential Fire Sprinkler Installation Guide or Uponor Radiant Installation Handbook for additional information. Standards ASTM E84; ASTM E119; ASTM E814; ASTM F877; ASTM F1960; CAN/CSA B137.5; NSF 14; NSF 61 Codes IBC; IMC; IPC; IRC; NPC of Canada; NSPC; UMC; UPC Listings cNSFus-pw; *cNSFus-pw-fs; cQAlus P321; HUD MR 1269; ICC-ES-PMG-1006; ICC-ES-PMG-1012; *UL 1821; *ULC/ORD-C199P; U.P. Code Related applications Contact information PEX-a plumbing systems Uponor Inc. Uponor Ltd. Hydronic radiant heating and cooling systems 5925 148t' Street West 6510 Kennedy Road Snow and ice melting systems Apple Valley, MN 55124 USA Mississauga, ON L5T 2X4 CANADA Turf conditioning systems Phone: 800.321.4739 Phone: 888.994.7726 Permafrost prevention systems Fax: 952.891.2008 Fax: 800.638.9517 AquaSAFE fire safety systems uponorpro.com uponorpro.com 1 ProPEX® is a registered trademark of Uponor, Inc. ProPEX- is a trademark of Uponor Ltd. ProPEX° Fire Sprinkler Adapter Submittal Information Revision B: March 17, 2009 Project Information Job Name: Location: Part No. Ordered: Engineer: Date Submitted: Contractor: Submitted By: Manufacturer's Representative: Approved By: Technical Data Material: 300 Series Stainless Steel Product Information and Application Use Use the ProPEX° Fire Sprinkler Adapter in conjunction with the appropriate sprinkler to provide a multi -purpose residential fire sprinkler system'. For residential applications, the system is installed with the cold -potable portion of the Uponor plumbing system. Make connections with Uponor ProPEX fittings. These fittings are designed for use only with 3/4" or 1" AquaPEX° White tubing in the Uponor AQUASAFE° Looped System. uponof ✓ Description Part A B C D E Weight Number ProPEX Fire Sprinkler Adapter, 3/4" PEX x 1/2" FNPT Q7517550 0.75" 1.88" 2.50" 1.82" 1.41" 0.268 lbs. ProPEX Fire Sprinkler Adapter, 1" PEX x 1/2" FNPT Q7511050 0.75" 1.88" 2.50" 2.06" 1.54" 0.408 lbs. Installation Use appropriate ProPEX Ring for connecting the tubing. Refer to the AquaPEX Installation Handbook or the Uponor AQUASAFE° Installation Guide for additional information. Standards CAN/CSA B137.5; ASTM F877; ASTM F 1960 Codes IPC; UPC; NSPC; IRC; IMC; NPC of Canada Listings ANSI/NSF 14- and 61-certified; U.P. Code; ICC ESR 1099; HUD MR 1269; UL 1821; ULC/ORD - C 199 P Related Applications PEX-a Plumbing Systems AQUASAFE Fire Safety Systems Contact Information Uponor, Inc. 5925 1481h Street West Apple Valley, MN 55124 USA Phone: (800) 321-4739 Fax: (952) 891-2008 www.uponor-usa.com Uponor Ltd. 2000 Argentia Rd., Plaza 1, Ste. 200 Mississauga, ON L5N 1W1 CANADA Phone: (888) 994-7726 Fax: (800) 638-9517 www.uponor.ca 'ProPEX° is a registered trademark of Uponor, Inc. ProPEXTM is a trademark of Uponor Ltd.