BLD2023-0826_Manufacturer_Specifications_and_Installation_Instructions_7.3.2023_9.17.37_AM_3644996
Air Conditioning & Heating HE4TING INPUT: 40,000-120,000 BTU/H 4 Standard Features • Heavy-duty aluminized -steel dual - diameter tubular heat exchanger • Single -stage gas valve • Durable Hot -surface igniter • Quiet, single -speed draft induced • Self -diagnostic control board • Color -coded low -voltage terminals • Multi -speed ECM blower motor • California Low NOx emissions models available • Can no longer be installed in California's South Coast Air Quality Management District (SCAQMD) on or after October 1, 2019. • AHRI Certified; ETL Listed GM9S801GC9S80 SINGLE -STAGE, MULTI -SPEED ECM, MULTI -POSITION GAS FURNACE 80% AFUE Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Dimensions ............................................ 5 Airflow Data ........................................... 7 Wiring Diagrams .................................. 19 Accessories .......................................... 20 Minimum Filter Sizes .......................... 20 Cabinet Features • Installation: — GM9S80 -upflow, horizontal left or right — GC9580- downflow, horizontal left or right • Convenient left or right connection for gas and electrical service • Heavy -gauge steel cabinet with durable baked -enamel finish • Foil faced insulated heat exchanger LIFETIME I 1 0 PARTS LTI. \` I Y COMPANY WITH COMPANY WITH OUALITYSYSTEM ENVIRONMEMLSYSTEM HEAT EXCHANDER LIMITED LIMITED WARRANTY' YEAR WARRANTY' C US CWrIFIEDBY DNVGL CERTIFIED BY.NVGL =1509001==15019001= Intertek * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat QBB. Exchanger Limited Warranty (good for as long as you own your home) and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-GM9S80/GC9580 www.goodmanmfg.com 05/22 Supersedes 08/21 NOMENCLATURE G M 9 C 80 060 3 B N ** 4 5,6 7,8,9 1 2 3 10 11 12 13,14 BRAND ENGINEERING G - Goodman® Brand Major/Minor Revisions A - Initial Release B - 1st Revision CONFIGURATION NOX M - Upflow/Horizontal N =>40 NG/J NOx C - Downflow/Horizontal X = < 40 NG/J NOx U = < 14NG/J NOx MOTOR CABINET WIDTH 9 - Nine Speed ECM A - 14" C - 21" B-17W' D-24W' GAS VALVE MAXIMUM CFM S - Single Stage 3 - 1200 CFM 4 - 1600 CFM C - Two Stage 5 - 2000 CFM AFUE MBTU/H 80 - 80% AFUE 92 - 92% AFUE 030 - 30,000 BTU/h 080 - 80,000 BTU/hz 96 - 96% AFUE 97 - 97% AFUE 040 - 40,000 BTU/h 100 - 100,000 BTU/h 060 - 60,000 BTU/h 120 - 120,000 BTU/h 2 www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 PRODUCT SPECIFICATIONS HEATING CAPACITY Input 40,000 60,000 60,000 60,000 80,000 80,000 80,000 80,000 100,000 120,000 Natural Gas Output 32,000 48,000 48,000 48,000 64,000 64,000 64,000 64,000 80,000 96,000 LP Gas Output 32,000 48,000 48,000 48,000 64,000 64,000 64,000 64,000 80,000 96,000 AFUE' 80 80 80 80 80 80 80 80 80 80 Available AC @ 0.5" ESP 3 3 3 4 3 4 4 5 5 5 Temperature Rise Range(°F) 25-55 20-50 20-50 20-50 35-65 35-65 35-65 35-65 35-65 40-70 CIRCULATOR BLOWER Size (D x W) 10" x 6" 10" x 6" 10" x 8" 10" x 8" 10" x 8" 10" x 8" 10" x 10" 10" x 10" 10" x 10" 10" x 10" Horsepower @1075 RPM 0.5 0.5 0.5 0.75 0.5 0.75 0.75 0.75 0.75 1 Speed 9 9 9 9 9 9 9 9 9 9 Vent Diameter Z 4" 4" 4" 4" 4" 4" 4" 4" 4" 4" No. of Burners 2 3 3 3 4 4 4 4 5 6 ELECTRICAL DATA Min. Circuit Ampacity s 8.7 8.7 8.7 12.45 8.7 12.45 12.45 12.45 12.45 15.3 Max. Overcurrent Device (amps) ° 15 15 15 15 15 15 15 15 15 20 SHIP WEIGHT (LBS) 86 90 100 108 116 120 132 132 132 132 DOE AFUE based upon Isolated Combustion System (ICS) Z Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). s Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ° Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection %" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-GM9S80/GC9S80 www.goodmanmfg.com GC9S80 PRODUCT SPECIFICATIONS HEATING CAPACITY Input 40,000 60,000 80,000 80,000 100,000 Natural Gas Output 32,000 48,000 64,000 64,000 80,000 LP Gas Output 32,000 48,000 64,000 64,000 80,000 AFUE' 80 80 80 80 80 Available AC @ 0.5" ESP 3 3 4 5 5 Temperature Rise Range (°F) 25-55 30-60 35-65 35-65 40-70 CIRCULATOR BLOWER Size (DxW) 10"X6" 10"X6" 10"X8" 101,X10" 101,X10" Horsepower @1075 RPM 1/2 1/2 3/4 1 1 Speed 9 9 9 9 9 Vent Diameter z 4" 4" 4" 4" 4" No. of Burners 2 3 4 4 5 ELECTRICAL DATA Min. Circuit Ampacity 3 8.7 8.7 12.45 15.3 15.3 Max. Overcurrent Device (amps) ° 15 15 15 20 20 SHIP WEIGHT (LBS) 90 94 107 115 115 DOE AFUE based upon Isolated Combustion System (ICS) a Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). a Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accor- dance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ° Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. NOTES • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection %" FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 DIMENSIONS Alternate Gas Inlet Alt. Flue Outlet — Horizontal Left A 1'/16" B 19%„ 33%" Alt. Gas Inlet High -Voltage Inlet 20 235�e' Alt. High Voltage 0 13'/<" is Low -Voltage Inlet Alt. Low Voltage 28" 23„ !IV19S800�403A* 14" 12%" GM9S800603A* 14" 12%" GM9S800603B* 17%" 16" GM9S800604B* 17%" 16" GM9S80080313* 17%" 16" GM9S800804B* 17%" 16" GM9S800804C* 21" 19'/:" GM9S800805C* 21" 19'/:" GM9S801005C* 21" 19'/:" GM9S801205D* 24%" 23" • Line voltage wiring can enter tnrougn the rignt or iert siae or rurnace. Low -voltage wiring can enter through the right or left side of furnace. • Conversion kits for high -altitude (4500+ft) natural gas operation are available. Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings, according to which entrance is used: Left: One 902 street elbow; one 2Y:" pipe nipple; one 909 elbow; straight pipe; one ground joint union Right: Straight pipe to reach gas valve MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS ' 24" clearance for serviceability recommended. 2 Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA 13149.1 and CAN/CSA 8142.2 (in Canada). Note: AMES80 approved for line contact in the horizontal position. SS-GM9S80/GC9S80 www.goodmanmfg.com 5 GC9S80 DIMENSIONS 18 %" 11W, A B 33 W 28" 19%g'� High -Voltage Electrical Low -Voltage , Electrical Gas Inlet 00 0 O o 0 0 NOTES • Line voltage wiring can enter through the right or left side of furnace. Low -voltage wiring can enter through the right or left side of furnace. • Conversion kits for high -altitude (4SOO+ft) natural gas operation are avail- able. Contact your Goodman distributor or dealer for details. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS 24" clearance for serviceability recommended. Z Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). Note: GMES80 approved for line contact in the horizontal position. www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 LOW STAGE COOLING AIRFLOW DATA qq G M 9S80 0403A* Y/Y1 LOW STAGE COOLING AIFLOW EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN) F01 658 585 545 495 444 390 332 151 F02 749 697 652 607 554 509 459 406 F03 925 881 840 800 760 721 681 645 F04^ 882 841 800 760 719 678 641 602 F05 1330 1295 1273 1251 1223 1195 1168 1142 F06 1130 1090 1059 1022 991 957 926 895 F07 1158 1113 1090 1057 1024 996 964 935 F08 1270 1235 1208 1179 1147 1119 1088 1060 F09 1417 1380 1359 1336 1314 1288 1261 1238 G M 9S80 0603A* Y/Y1 F01 659 599 542 490 437 383 320 N/A F02 1268 1221 1188 1154 1122 1091 1060 1029 F03 1087 1044 1008 973 938 905 871 841 F04^ 1118 1070 1033 997 963 929 896 865 F05 1308 1262 1224 1197 1167 1141 1117 1089 F06 868 823 780 741 699 662 624 584 F07 922 877 835 795 757 718 679 642 F08 1382 1341 1311 1291 1263 1234 1206 1177 F09 1492 1448 1409 1381 1354 1332 1310 1288 G M 9S80 0603B* Y/Y1 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04^ 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286 G M 9S80 0604B* Y/Y1 F01 764 695 630 559 485 415 358 N/A F02 1287 1235 1191 1147 1104 1062 1020 979 F03 1339 1301 1258 1217 1174 1131 1090 1048 F04^ 1396 1346 1298 1257 1217 1175 1135 1098 F05 1185 1135 1088 1040 992 947 901 855 F06 1500 1460 1420 1360 1380 1294 1256 1219 F07 1591 1539 1493 1454 1416 1379 1347 1311 F08 1675 1622 1583 1545 1510 1474 1440 1402 F09 1790 1741 1701 1668 1631 1599 1567 1532 G M 9S80 0803B* Y/Y1 F01 710 646 580 515 432 367 314 274 F02 1298 1255 1216 1178 1140 1102 1067 1028 F03 1209 1166 1124 1083 1045 1005 964 923 F04^ 1138 1091 1045 1001 959 920 876 832 FOS 1391 1352 1314 1278 1241 1209 1175 1140 F06 977 931 880 836 785 734 683 626 F07 1036 985 940 895 848 799 751 705 F08 1456 1414 1376 1341 1302 1270 1238 1200 F09 1533 1488 1452 1415 1383 1350 1317 1286 Note: ^ DEFAULT SPEED SS-GM9S80/GC9S80 www.goodmanmfg.com GM9S80 Low STAGE COOLING AIRFLOW DATA (CONT.) COOLINGLOW STAGE F01 EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN) 841 657 595 522 439 367 315 N/A F02 1141 1089 1045 1001 958 914 869 823 F03 1311 1267 1226 1189 1150 1114 1072 1034 F04A 1395 1347 1309 1270 1233 1199 1164 1125 G M 9S80 0804B* Y/Y1 F05 1490 1447 1407 1373 1336 1303 1269 1237 F06 1553 1510 1469 1435 1401 1368 1335 1300 F07 1593 1548 1508 1474 1440 1409 1376 1343 F08 1776 1735 1695 1661 1628 1601 1570 1542 F09 1853 1812 1773 1739 1708 1679 1650 1623 F01 831 750 671 588 501 405 348 300 F02 1214 1158 1103 1045 989 936 883 823 F03 1303 1249 1191 1136 1081 1028 974 928 F04A 1426 1375 1324 1277 1229 1177 1124 1078 G M 9S80 0804C* Y/Y1 F05 1518 1465 1418 1372 1328 1284 1237 1195 F06 1588 1539 1494 1447 1401 1358 1313 1267 F07 1710 1666 1632 1595 1554 1512 1473 1431 F08 1785 1751 1717 1675 1639 1596 1557 1516 F09 1845 1805 1771 1733 1695 1655 1618 1576 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04A 1587 1544 1506 1459 1416 1372 1323 1281 G M 9S80 0805C* Y/Y1 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 F01 802 724 637 551 468 389 342 294 F02 1405 1356 1308 1262 1210 1182 1155 1102 F03 1574 1531 1484 1440 1392 1357 1306 1256 F04A 1619 1575 1526 1489 1446 1404 1355 1313 G M 9S80 1005C* Y/Y1 F05 1688 1641 1600 1557 1513 1477 1428 1381 F06 1811 1769 1730 1686 1649 1610 1572 1525 F07 1857 1812 1774 1733 1697 1662 1622 1586 F08 1892 1850 1805 1774 1735 1692 1658 1621 F09 2116 2073 2039 2005 1981 1945 1909 1879 F01 851 774 692 615 535 470 411 359 F02 1677 1629 1583 1540 1498 1449 1399 1349 F03 1537 1489 1444 1404 1365 1322 1272 1211 F04A 1416 1365 1315 1267 1220 1163 1106 1048 G M 9S80 1205D* Y/Y1 F05 1154 1098 1043 983 932 874 819 755 F06 1806 1764 1729 1688 1654 1615 1578 1535 F07 1869 1816 1773 1731 1693 1661 1629 1589 F08 1947 1903 1865 1833 1802 1769 1743 1708 F09 2107 2066 1 2030 1 1996 1963 1932 1899 1867 Note: A DEFAULT SPEED www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 HIGH STAGE COOLING AIRFLOW DATA F01 COOLINGHIGH STAGE EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN) 658 585 545 495 444 390 332 151 F02 749 697 652 607 554 509 459 406 F03 925 881 840 800 760 721 681 645 F04 882 841 800 760 719 678 641 602 G M 9S80 0403A* Y2 F05^ 1330 1295 1273 1251 1223 1195 1168 1142 F06 1130 1090 1059 1022 991 957 926 895 F07 1158 1113 1090 1057 1024 996 964 935 F08 1270 1235 1208 1179 1147 1119 1088 1060 F09 1417 1380 1359 1336 1314 1288 1261 1238 F01 659 599 542 490 437 383 320 N/A F02 1268 1221 1188 1154 1122 1091 1060 1029 F03 1087 1044 1008 973 938 905 871 841 F04 1118 1070 1033 997 963 929 896 865 G M 9S80 0603A* Y2 F05^ 1308 1262 1224 1197 1167 1141 1117 1089 F06 868 823 780 741 699 662 624 584 F07 922 877 835 795 757 718 679 642 F08 1382 1341 1311 1291 1263 1234 1206 1177 F09 1492 1448 1409 1381 1354 1332 1310 1288 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 G M 9S80 0603B* Y2 F05^ 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286 F01 764 695 630 559 485 415 358 N/A F02 1287 1235 1191 1147 1104 1062 1020 979 F03 1339 1301 1258 1217 1174 1131 1090 1048 F04 1396 1346 1298 1257 1217 1175 1135 1098 G M 9S80 0604B* Y2 F05^ 1185 1135 1088 1040 992 947 901 855 F06 1500 1460 1420 1360 1380 1294 1256 1219 F07 1591 1539 1493 1454 1416 1379 1347 1311 F08 1675 1622 1583 1545 1510 1474 1440 1402 F09 1790 1741 1701 1668 1631 1599 1567 1532 F01 710 646 580 515 432 367 314 274 F02 1298 1255 1216 1178 1140 1102 1067 1028 F03 1209 1166 1124 1083 1045 1005 964 923 F04 1138 1091 1045 1001 959 920 876 832 G M 9S80 0803B* Y2 F05^ 1391 1352 1314 1278 1241 1209 1175 1140 F06 977 931 880 836 785 734 683 626 F07 1036 985 940 895 848 799 751 705 F08 1456 1414 1376 1341 1302 1270 1238 1200 F09 1533 1488 1452 1415 1383 1350 1317 1286 Note: ^ DEFAULT SPEED SS-GM9S80/GC9S80 www.goodmanmfg.com GM9S80 HIGH STAGE COOLING AIRFLOW DATA (CONT.) COOLINGHIGH STAGE • F01 841 657 595 522 439 367 315 N/A F02 1141 1089 1045 1001 958 914 869 823 F03 1311 1267 1226 1189 1150 1114 1072 1034 F04 1395 1347 1309 1270 1233 1199 1164 1125 G M9S80 0804B* Y2 F05^ 1490 1447 1407 1373 1336 1303 1269 1237 F06 1553 1510 1469 1435 1401 1368 1335 1300 F07 1593 1548 1508 1474 1440 1409 1376 1343 F08 1776 1735 1695 1661 1628 1601 1570 1542 F09 1853 1812 1773 1739 1708 1679 1650 1623 F01 831 750 671 588 501 405 348 300 F02 1214 1158 1103 1045 989 936 883 823 F03 1303 1249 1191 1136 1081 1028 974 928 F04 1426 1375 1324 1277 1229 1177 1124 1078 0804C04C* G Y2 F05^ 1518 1465 1418 1372 1328 1284 1237 1195 F06 1588 1539 1494 1447 1401 1358 1313 1267 F07 1710 1666 1632 1595 1554 1512 1473 1431 F08 1785 1751 1717 1675 1639 1596 1557 1516 F09 1845 1805 1771 1733 1695 1655 1618 1576 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 G M9S80 0805C* Y2 F05^ 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 F01 802 724 637 551 468 389 342 294 F02 1405 1356 1308 1262 1210 1182 1155 1102 F03 1574 1531 1484 1440 1392 1357 1306 1256 F04 1619 1575 1526 1489 1446 1404 1355 1313 G M9S80 1005C* Y2 F05^ 1688 1641 1600 1557 1513 1477 1428 1381 F06 1811 1769 1730 1686 1649 1610 1572 1525 F07 1857 1812 1774 1733 1697 1662 1622 1586 F08 1892 1850 1805 1774 1735 1692 1658 1621 F09 2116 2073 2039 2005 1981 1945 1909 1879 F01 851 774 692 615 535 470 411 359 F02 1677 1629 1583 1540 1498 1449 1399 1349 F03 1537 1489 1444 1404 1365 1322 1272 1211 F04 1416 1365 1315 1267 1220 1163 1106 1048 G M9S80 1205D* Y2 F05^ 1154 1098 1043 983 932 874 819 755 F06 1806 1764 1729 1688 1654 1615 1578 1535 F07 1869 1816 1773 1731 1693 1661 1629 1589 F08 1947 1903 1865 1833 1802 1769 1743 1708 F09 2107 2066 2030 1996 1963 1932 1899 1867 Note:^ DEFAULTSPEED RECOMMENDED AIRFLOW SPEEDS FURNACE MODEL O. CONNECTION WITH Y2 2 STAGE OUTDOOR MODELS Y1 *M9S800805C* F08 F02 *M9S801205D* F06 F05 10 www.goodmanmfg.com SS-GM9S80/GC9S80 GM9S80 CIRCULATION AIRFLOW DATA COLUMN)CIRCULATION AIFLOW EXTERNAL STATIC PRESSURE, (INCHES WATER Pill III IN F01 658 585 545 495 444 390 332 151 F02 749 697 652 607 554 509 459 4 66 F03 925 881 840 800 760 721 681 645 F04 882 841 800 760 719 678 641 602 G M 9S80 0403A* G F05 1330 1295 1273 1251 1223 1195 1168 1142 F06 1130 1090 1059 1022 991 957 926 895 F07 1158 1113 1090 1057 1024 996 964 935 F08 1270 1235 1208 1179 1147 1119 1088 1060 F09 1417 1380 1359 1336 1314 1288 1261 1238 F01 659 599 542 490 437 383 320 N/A F02 1268 1221 1188 1154 1122 1091 1060 1029 F03 1087 1044 1008 973 938 905 871 841 F04 1118 1070 1033 997 963 929 896 865 G M 9S80 0603A* G F05 1308 1262 1224 1197 1167 1141 1117 1089 F06 868 823 780 741 699 662 624 584 F07 922 877 835 795 757 718 679 642 F08 1382 1341 1311 1291 1263 1234 1206 1177 F09 1492 1448 1409 1381 1354 1332 1310 1288 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 G M 9S80 0603B* G F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286 F01 764 695 630 559 485 415 358 N/A F02 1287 1235 1191 1147 1104 1062 1020 979 F03 1339 1301 1258 1217 1174 1131 1090 1048 F04 1396 1346 1298 1257 1217 1175 1135 1098 G M 9S80 0604B* G F05 1185 1135 1088 1040 992 947 901 855 F06 1500 1460 1420 1360 1380 1294 1256 1219 F07 1591 1539 1493 1454 1416 1379 1347 1311 F08 1675 1622 1583 1545 1510 1474 1440 1402 F09 1790 1741 1701 1668 1631 1599 1567 1532 F01 710 646 580 515 432 367 314 274 F02 1298 1255 1216 1178 1140 1102 1067 1028 F03 1209 1166 1124 1083 1045 1005 964 923 F04 1138 1091 1045 1001 959 920 876 832 G M 9S80 0803B* G F05 1391 1352 1314 1278 1241 1209 1175 1140 F06 977 931 880 836 785 734 683 626 F07 1036 985 940 895 848 799 751 705 F08 1456 1414 1376 1341 1302 1270 1238 1200 F09 1533 1488 1452 1415 1383 1350 1317 1286 Note: A DEFAULT SPEED SS-GM9S80/GC9S80 www.goodmanmfg.com 11 GM9S80 CIRCULATION AIRFLOW DATA (CONT.) F01 CIRCULATION AIFLOW EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN) 841 657 595 522 439 367 !315 N/AF02 1141 1089 1045 1001 958 914 69 823 F03 1311 1267 1226 1189 1150 1114 1072 1034 F04 1395 1347 1309 1270 1233 1199 1164 1125 G M 9S80 0804B* G F05 1490 1447 1407 1373 1336 1303 1269 1237 F06 1553 1510 1469 1435 1401 1368 1335 1300 F07 1593 1548 1508 1474 1440 1409 1376 1343 F08 1776 1735 1695 1661 1628 1601 1570 1542 F09 1853 1812 1773 1739 1708 1679 1650 1623 F01 831 750 671 588 501 405 348 300 F02 1214 1158 1103 1045 989 936 883 823 F03 1303 1249 1191 1136 1081 1028 974 928 F04 1426 1375 1324 1277 1229 1177 1124 1078 G M 9S80 0804C* G F05 1518 1465 1418 1372 1328 1284 1237 1195 F06 1588 1539 1494 1447 1401 1358 1313 1267 F07 1710 1666 1632 1595 1554 1512 1473 1431 F08 1785 1751 1717 1675 1639 1596 1557 1516 F09 1845 1805 1771 1733 1695 1655 1618 1576 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 G M 9S80 0805C* G F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 F01 802 724 637 551 468 389 342 294 F02 1405 1356 1308 1262 1210 1182 1155 1102 F03 1574 1531 1484 1440 1392 1357 1306 1256 F04 1619 1575 1526 1489 1446 1404 1355 1313 G M 9S80 1005C* G F05 1688 1641 1600 1557 1513 1477 1428 1381 F06 1811 1769 1730 1686 1649 1610 1572 1525 F07 1857 1812 1774 1733 1697 1662 1622 1586 F08 1892 1850 1805 1774 1735 1692 1658 1621 F09 2116 2073 2039 2005 1981 1945 1909 1879 F01 851 774 692 615 535 470 411 359 F02 1677 1629 1583 1540 1498 1449 1399 1349 F03 1537 1489 1444 1404 1365 1322 1272 1211 F04 1416 1365 1315 1267 1220 1163 1106 1048 G M 9S80 1205D* G F05 1154 1098 1043 983 932 874 819 755 F06 1806 1764 1729 1688 1654 1615 1578 1535 F07 1869 1816 1773 1731 1693 1661 1629 1589 F08 1947 1903 1865 1833 1802 1769 1743 1708 F09 2107 2066 2030 1996 1963 1932 1899 1867 Note: A DEFAULT SPEED 12 www.goodmanmfg.com SS-GM9S80/GC9S80 Ce11��SifilC►f-,UPR a _A .-TiVO►li G M 9S80 0403A* w/w1 F01^^ HEATING AIFLOW EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN) 658 N/A 585 N/A 545 N/A 495 N/A 444 F02^ 749 40 697 42 652 45 607 49 554 F03 925 32 881 34 840 35 800 37 760 F04 882 34 841 35 800 37 760 39 719 G M 9S80 0603A* w/W1 F01^^ 659 N/A 599 N/A 542 N/A 490 N/A 437 F02^ 1268 35 1221 36 1188 37 1154 38 1122 F03 1087 41 1044 43 1008 44 973 46 938 F04 1118 40 1070 42 1033 43 997 45 963 G M 9S80 0603B* w/W1 F01^^ 720 N/A 660 N/A 614 N/A 542 N/A 468 F02^ 1289 34 1260 35 1232 36 1194 37 1161 F03 1125 40 1089 41 1052 42 1013 44 973 F04 1252 36 1198 37 1153 39 1110 40 1069 G M 9S80 0604B* w/W1 F01^^ 764 N/A 695 N/A 630 N/A 559 N/A 485 F02^ 1287 35 1235 36 1191 37 1147 39 1104 F03 1339 33 1301 34 1258 35 1217 37 1174 F04 1396 32 1346 33 1298 34 1257 35 1217 G M 9S80 0803B* w/W1 F01^^ 710 N/A 646 N/A 580 N/A 515 N/A 432 F02^ 1298 46 1255 47 1216 49 1178 50 1140 F03 1209 49 1166 51 1124 53 1083 55 1045 F04 1138 52 1091 54 1045 57 1001 59 959 G M 9S80 0804B* w/W1 F01^^ 841 N/A 657 N/A 595 N/A 522 N/A 439 F02^ 1141 52 1089 54 1045 57 1001 59 958 F03 1311 45 1267 47 1226 48 1189 50 1150 F04 1395 42 1347 44 1309 45 1270 47 1233 G M 9S80 0804C* w/W1 F01^^ 831 N/A 750 N/A 671 N/A 588 N/A 501 F02^ 1214 49 1158 51 1103 54 1045 57 989 F03 1303 45 1249 47 1191 50 1136 52 1081 F04 1426 42 1375 43 1324 45 1277 46 1 1229 G M 9S80 0805C* w/W1 F01^^ 837 N/A 752 N/A 671 N/A 576 N/A 501 F02^ 1316 45 1270 47 1218 49 1166 51 1114 F03 1353 44 1323 45 1286 46 1235 48 1183 F04 1587 37 1544 38 1506 39 1459 41 1416 G M 9S80 1005C* W/W 1 F01^^ 802 N/A 724 N/A 637 N/A 551 N/A 468 F02^ 1405 53 1356 55 1308 57 1262 59 1210 F03 1574 47 1531 48 1484 50 1440 51 1392 F04 1619 46 1575 47 1526 49 1489 50 1446 G M 9S80 1205D* w/W1 F01^^ 851 N/A 774 N/A 692 N/A 615 N/A 535 F02^ 1677 53 1629 55 1583 56 1S40 58 1498 F03 1537 58 1489 60 1444 62 1404 63 1365 F04 AA 1416 N/A 1365 N/A 1315 N/A 1267 N/A 1220 Note: ^ DEFAULT SPEED AA NOT RECOMMENDED FOR HEATING SS-GM9S80/GC9S80 www.goodmanmfg.com 13 GC9S80 Low STAGE COOLING AIRFLOW DATA qq LOW STAGE COOLING AIFLOW EXTERNAL STATIC PRESSURE, (INCHES WATER • RFO1 712 663 610 559 514 462 !3795337F02 1120 1081 1053 1022 990 955 87 F03 929 891 858 815 772 737 699 664 F04^ 1073 1031 1003 969 922 891 854 822 GC9S80 0403A* Y/Y1 F05 1212 1198 1161 1138 1103 1076 1037 1007 F06 871 830 789 743 702 665 628 583 F07 825 784 741 694 650 609 563 520 F08 1274 1252 1220 1195 1169 1145 1110 1084 F09 1362 1342 1307 1273 1252 1237 1211 1185 F01 706 655 604 555 505 455 395 328 F02 1035 991 951 913 876 844 807 770 F03 932 887 844 806 767 728 689 651 F04^ 897 851 808 764 725 686 646 603 GC9S80 0603A* Y/Y1 F05 1123 1077 1041 1006 973 941 907 875 F06 1155 1113 1074 1039 1006 974 945 913 F07 1255 1214 1181 1147 1116 1087 1056 1028 F08 1388 1331 1298 1266 1235 1207 1179 1151 F09 1421 1380 1348 1318 1289 1262 1233 1207 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04^ 1459 1414 1371 1336 1297 1264 1229 1193 GC9S80 0804B* Y/Y1 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 F01 1022 813 674 585 511 431 334 282 F02 1453 1407 1332 1259 1190 1143 1064 1003 F03 1176 1105 1020 935 864 797 729 673 F04^ 1710 1660 1613 1560 1505 1424 1353 1296 GC9S80 0805C* Y/Y1 F05 1843 1786 1747 1690 1643 1575 1497 1435 F06 1859 1819 1779 1734 1691 1641 1593 1520 F07 2028 1982 1946 1907 1861 1814 1749 1683 F08 2096 2045 2006 1974 1927 1882 1818 1765 F09 2203 2170 2138 2113 2074 2032 1990 1948 F01 956 777 675 587 468 377 324 296 F02 1460 1404 1350 1299 1251 1203 1150 1098 F03 1561 1499 1441 1385 1336 1289 1243 1197 F04^ 1628 1571 1521 1472 1425 1380 1337 1291 GC9S80 1005C* Y/Y1 FOS 1714 1659 1611 1564 1519 1473 1432 1387 F06 1833 1784 1735 1688 1645 1605 1562 1520 F07 1899 1853 1804 1761 1720 1681 1640 1602 F08 1926 1894 1849 1807 1764 1720 1683 1642 F09 2222 2174 2132 2090 2053 2013 1976 1944 Note: ^ DEFAULT SPEED 14 www.goodmanmfg.com SS-GM9S80/GC9S80 GC9S80 HIGH STAGE COOLING AIRFLOW DATA •. . COOLINGLOW STAGE • EXTERNAL STATIC PRESSURE, (INCHES WATER C• '® '® '®�Pillis F01 712 663 610 559 514 462 395 337 F02 1120 1081 1053 1022 990 955 918 887 F03 929 891 858 815 772 737 699 664 F04 1073 1031 1003 969 922 891 854 822 GC9S80 0403A* Y2 F05^ 1212 1198 1161 1138 1103 1076 1037 1007 F06 871 830 789 743 702 665 628 583 F07 825 784 741 694 650 609 563 520 F08 1274 1252 1220 1195 1169 1145 1110 1084 F09 1362 1342 1307 1273 1252 1237 1211 1185 F01 706 655 604 555 505 455 395 328 F02 1035 991 951 913 876 844 807 770 F03 932 887 844 806 767 728 689 651 F04 897 851 808 764 725 686 646 603 GC9S80 0603A* Y2 F05^ 1123 1077 1041 1006 973 941 907 875 F06 1155 1113 1074 1039 1006 974 945 913 F07 1255 1214 1181 1147 1116 1087 1056 1028 F08 1388 1331 1298 1266 1235 1207 1179 1151 F09 1421 1380 1348 1318 1289 1262 1233 1207 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 GC9S80 0804B* Y2 F05^ 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 F01 1022 813 674 585 511 431 334 282 F02 1453 1407 1332 1259 1190 1143 1064 1003 F03 1176 1105 1020 935 864 797 729 673 F04 1710 1660 1613 1560 1505 1424 1353 1296 GC9S80 0805C* Y2 F05^ 1843 1786 1747 1690 1643 1575 1497 1435 F06 1859 1819 1779 1734 1691 1641 1593 1520 F07 2028 1982 1946 1907 1861 1814 1749 1683 F08 2096 2045 2006 1974 1927 1882 1818 1765 F09 2203 2170 2138 2113 2074 2032 1990 1948 F01 956 777 675 587 468 377 324 296 F02 1460 1404 1350 1299 1251 1203 1150 1098 F03 1561 1499 1441 1385 1336 1289 1243 1197 F04 1628 1571 1521 1472 1425 1380 1337 1291 GC9S80 1005C* Y2 F05^ 1714 1659 1611 1564 1519 1473 1432 1387 F06 1833 1784 1735 1688 1645 1605 1562 1520 F07 1899 1853 1804 1761 1720 1681 1640 1602 F08 1926 1894 1849 1807 1764 1720 1683 1642 F09 2222 2174 2132 2090 2053 2013 1976 1944 RECOMMENDED AIRFLOW SPEEDS FOR CONNECTION WITH 2 STAGE OUTDOOR MODELS SS-GM9S80/GC9S80 www.goodmanmfg.com 15 GC9S80 CIRCULATION AIRFLOW DATA CIRCULATION AIFLO EXTERNAL STATIC PRESSURE, (INCHES WATER • F01 37 712 663 610 559 514 4672 79187887 F02 1120 1081 1053 1022 990 F03 929 891 858 815 772 664 F04 1073 1031 1003 969 922 891 854 822 GC9S80 0403A* G F05 1212 1198 1161 1138 1103 1076 1037 1007 F06 871 830 789 743 702 665 628 583 F07 825 784 741 694 650 609 563 520 F08 1274 1252 1220 1195 1169 1145 1110 1084 F09 1362 1342 1307 1273 1252 1237 1211 1185 F01 706 655 604 555 505 455 395 328 F02 1035 991 951 913 876 844 807 770 F03 932 887 844 806 767 728 689 651 F04 897 851 808 764 725 686 646 603 GC9S80 0603A* G F05 1123 1077 1041 1006 973 941 907 875 F06 1155 1113 1074 1039 1006 974 945 913 F07 1255 1214 1181 1147 1116 1087 1056 1028 F08 1388 1331 1298 1266 1235 1207 1179 1151 F09 1421 1380 1348 1318 1289 1262 1233 1207 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 GC9S80 0804B* G F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 F01 1022 813 674 585 511 431 334 282 F02 1453 1407 1332 1259 1190 1143 1064 1003 F03 1176 1105 1020 935 864 797 729 673 F04 1710 1660 1613 1560 1505 1424 1353 1296 GC9S80 0805C* G F05 1843 1786 1747 1690 1643 1575 1497 1435 F06 1859 1819 1779 1734 1691 1641 1593 1520 F07 2028 1982 1946 1907 1861 1814 1749 1683 F08 2096 2045 2006 1974 1927 1882 1818 1765 F09 2203 2170 2138 2113 2074 2032 1990 1948 F01 956 777 675 587 468 377 324 296 F02 1460 1404 1350 1299 1251 1203 1150 1098 F03 1561 1499 1441 1385 1336 1289 1243 1197 F04 1628 1571 1521 1472 1425 1380 1337 1291 GC9S80 1005C* G F05 1714 1659 1611 1564 1519 1473 1432 1387 F06 1833 1784 1735 1688 1645 1605 1562 1520 F07 1899 1853 1804 1761 1720 1681 1640 1602 F08 1926 1894 1849 1807 1764 1720 1683 1642 F09 2222 2174 2132 2090 2053 2013 1976 1944 Note: A DEFAULT SPEED 16 www.goodmanmfg.com SS-GM9S80/GC9S80 GC9S80 HEATING AIRFLOW DATA GC9S80 0403A* W/W1 F01"^ HEATING AIFLOW EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN) 712 N/A 663 N/A 610 N/A 559 N/A 514 F02^ 1120 26 1081 27 1053 28 1022 29 990 F03 929 32 891 33 858 35 815 36 772 F04 1073 28 1031 29 1003 30 969 31 922 GC9S80 0603A* W/W1 F01"^ 706 N/A 655 N/A 604 N/A 555 N/A 505 F02^ 1035 43 991 45 951 47 913 49 876 F03 932 48 887 50 844 53 806 55 767 F04"^ 897 N/A 851 N/A 808 N/A 764 N/A 725 GC9S80 0804B* W/W1 F01"^ 760 N/A 697 N/A 636 N/A 569 N/A 481 F02^ 1286 46 1238 48 1196 50 1157 51 1117 F03 1393 43 1348 44 1308 45 1270 47 1230 F04 1459 41 1414 42 1371 43 1336 44 1297 GC9S80 0805C* W/W1 F01"^ 1022 N/A 813 N/A 674 N/A 585 N/A 511 F02^ 1453 41 1407 42 1332 45 1259 47 1190 F03 AA 1176 N/A 1105 N/A 1020 N/A 935 N/A 864 F04 1710 35 1660 36 1613 37 1560 38 1505 GC9S80 1005C* W/W1 F01"^ 956 N/A 777 N/A 675 N/A 1 587 N/A 468 F02^ 1460 51 1404 53 1350 55 1299 57 1251 F03 1561 47 1499 49 1441 51 1385 53 1336 F04 1628 1 46 1571 47 1521 49 1472 50 1425 Note: A DEFAULT SPEED AA NOT RECOMMENDED FOR HEATING SS-GM9S80/GC9S80 www.goodmanmfg.com 17 00 m 0 0 0- 3 cu 0 3 Ln LP ko 00 W 0 c 00 W 0 BTU/H OUTPUT VS. TEMPERATURE RISE CHART 100 90 80 70 w 60 or Q or a 50 -1411 w F- 40 30 20 10 30 40 50 60 70 80 90 100 110 120 130 140 150 OUTPUT BTU/H x 1,000 600 CFM Z--700— soo 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM - FORMULAS BTU/h Output = CFRM x 1.08 x Rise BTU/H Output Rise = _ CFM CFM x 1.08 _ — — — WIRING DIAGRAM A O r� TO =GND 115 VAC/ 10160 HZ n r l POWER SUPPLY WITH 1... OVERCURRENT ID BLOWER PRESSURE SWITCH O J11-1 PROTECTION DEVICE HOT < z Ir L SURFACE < IGNITER K r l WARNING:DISCONNECT POWER BEFORE c Y — — N SERVICING. WIRING N W TO UNIT MUST BE DISCONNECT PROPERLY POLARIZED 2 CIRCUIT AND GROUNDED. 1 CONNECTOR TO 115VAC/ 10 /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE C GY FLAME SENSOR WARNING: L rZ I x DISCONNECT POWER GAS VALVE HI BR BEFORE SERVICING. I WIRING TO UNIT MUST BE PROPERLY I POLARIZED AND DISCONNECT SOME UNITS MAY HAVE GROUNDED. 1 ROLLOUT SWITCH PUI_ PK__(P_ c r-� DOOR SWITCH L J L J L J —AUTO RESET PRIMARY m JUNCTION BOX x DRAFT LOWE CIRCUIIATOR BLOWERR BLWR ER COMPARTMENT GND LINE No NEUTR ER COMPARTMENT U y m AUTO RESET AUXILIARY PKIDIFI�R HUM' r NEUTRA LIMITCONTROL HUM EAC ELECTRONIC AI`CLEANJR NEUTRA p NEUTRAL t �.INDLO 2 HOT SURFACE 2 �G = x FE IGNITER FLA ME SENSOR LINE 115VAC NEUTR, z z RANSFORME TH (s) 24 VAC x RLO (IS MANUAL SET ROLLOUT LIMITS IT< • RD 12L r R TO ,—C—D Io AUTI RAUTO RESET AUX LIMIT PR M/ HL011) t5 / Rn ER OR OOCv IIII PRESS WITCH T READ CODES FROM LEFTTO RIGHT lJ O z ICR HLI (8) � G 'Q C MV Eu) HI n EHUM I O A EN C © F I GAS N VALVE WM11 R G CY/Y1 Y2 �' T^ TR 111 ECM MTR IN000R HARNESS TO AIR p CIRCULATOR G GN Z n y BIK MICRO_ BLWR GND L BK 1 ur INTERGRATED CONTROL MODULE C 1 p x /77 ; NOTES: GND T 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.]AMPS. x 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED CHASSIS BLOWER WHEN SERVICING, ACE CIRCULATOR BLOWER I GROUND COMPARTMENT MUST E REPLACED 3. IF ANY OF THE ORI R MOSNAL TBEREPLACED WITH RE AS SUPPLIED IT WIRING MH THE ATERIAL DOOR SWITCH (OPEN WHEN HAVING ATEMPERATURE RATING OF AT LEAST 105'0. USE COPPER DOOR OPEN CONDO,UNIT MUST BE PER 1 . ANT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E.C. AND RECALL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, Error Code Status Seven Se ment Dis la eE eE eE Internal Faults or IRQ Loss Lockout Due to Excessive Retries or Recycles E E 0 Pressure Switch Stuck Closed E E 1 Pressure Switch Open E E 2 Open High Limit Switch E E S Flame Detected When no Flame Should be Present E E 4 Open Fuse E E 5 Low Flame Signal E E 6 Ignitor Relay Fault E E L Reversed Line Polarity or Grounding Error E E A Internal Gas Valve Error E E b External Gas Valve Error E E C Open Rollout Switch E 1 1 Ignitor Open E E n Inducer Relay Error E E j TWIN Error E E H DEE ESS SWITCH FOR TORE THAN 2 SECONDS WHILE IN STANDBY NOHERMOSTAT —INPUTS) COLOR CODES: EQUIPMENTGND /07 PK PINK FIELD GND ?E BR BROWN H W HITE FIELD SPLICE b- BL BLUE SWITCH (TEMP.) GY GRAY IGNITER ZrLn� RD RED L YELLOW SWITCH (PRESS.) OR ORANGE PU PURPLE OVERCURRENT PROT.DEV ICE F GN GREEN BK BLACK JUNCTION TERMINAL -0- INTERNAL TO r INTEGRATED CONTROL — PLUG CONNECTION $ LOW VOLTAGE (24V) }t LOW VOLTAGE FIELD — �h HI VOLTAGE (115V) 0140F02640-A HI VOLTAGE FIELD C m y 0 3 w m. o C m 7 'O a U w '3 0 L w mO � w . SS-GM9S80/GC9S80 www.goodmanmfg.com 19 ACCESSORIES Fossil Fuel AFE18-60A V V V V V V V V V V (Dual Fuel) Kit High -Altitude HANG20 V V V V V V V V V V Natural Gas Kit Low LP Gas LPLP03 V V V V V V V V V V Pressure Switch LPT-03 LP Conversion Kits V V V V V V V V V V MVK-01 * Masonry Vent Kit V V V V V V V V V — MVK 02 * Masonry Vent Kit _ _ _ _ _ _ _ _ _ V (for 120k model only) * Upflow applications only MODEL Downflow Sub -Base SBT14 14" V V — — — Downflow Sub -Base SBT17 _ _ V 17.5" Downflow Sub -Base SBT21 — — — V V 21" Fossil Fuel (Dual AFE18-60A Fuel) Kit V V V V V High -Altitude Natu- HANG20 V V V V V ral Gas Kit Low LP Gas Pressure LPLP03 V V V V V Switch LPT-03 LP Conversion Kits V V V V V MINIMUM FILTER SIZES Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. Use 2 - 16 x 25 filters on side returns or 20 x 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. Our continuing commitment to quality products may mean a change in specifications without notice. 02022 DA/K/NCOMFORT TECHNOLOGIES MANUFACTUR/NG.L.P. • Houston, Texas • Printed in the USA. 20 www.goodmanmfg.com SS-GM9S80/GC9S80