Loading...
APPROVED BLD-BLD2022-0691+Arch plans +7.11.2022_12.54.53_PM+298117917.4' N 000 35' 27" / o S. �h � , I / i I � I I 25.37' N 00° 35' 27" W i' I o /i I i I PROPERTY - I SETBACKS I � I City Of Edmonds Building Department Work NEW GARAGE - - - - - - -------------- Address 22408 95TH PL W ------------------------------------------------ --------------------------------- Owner GUI ❑ MAN Approved Date 071119112022 Building Official Permit Number' bId2022-0691 OB IN ELECTRICAL ERMIT FROM S ATE LABOR & INDUSTRIES -----lease use I APPROVED LIDPLANS MUST BE stand alon I L0 ON JOB SITE SNO OMISH COUNTY 00 00544300008001 I z 8038 SQFT I REAR PATI I � I I 00 I I �I I I 8 0 I I 0 I I1 II /RESENCE noo zGAS METER FF ' SQ 56 CD III I -ELEC METER 7 -6" I RIDGE 390.83' ° I I WALL TOP PLATE 388.33' I 8.15' x 16.5' MIN CLEAN 18'-011 PJ RKING I OUT ��9�c�'o O° o j AkEA (TYP) - - - - - - XI Ix 7'-611 NEW GARAGE x I CP\ FF = 380.0' o x t xx x * x c\ x ° A ILY. 7 X x*\ 216SQFT GRAVEL � �x x xxl' �xl L?�ti PARKING I x xX*X x / xxx X x XxXx1x x xX - -Q 98��0 I xl_x X p� _ AREA W -1 - - - 5 x � xX '` x � xX x x � ' x* � � Ix X/x x ICC0 X x x xxXX x�/xxx o C O x x.4-x x x XXx � x x / I S W/ SPLASH w z w LUx* x x I BLO (TYP) - x af w I xx x X x O �X ern Ix* I >LU �xx I U) O W W w U x 2 I O ® 4 - -- --- 67.4 N 0 06 37 G TREE DRIP CIRCLE (TYP) WATER- L ETER LJ GAS MAIN I SEWER MAIN I 95th Place West LEGEND AVERAGE HEIGHT CALCULATIONS 379.88' + 379.88' + 379.88' + 379.88' = 379.88' 0 4 Maximum Height = 25.0' Maximum Elevation = 404.88' Proposed Ridge Elevation = 390.83' < 404.88' ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE SIGNIFICANT TREES ID TRUNK RAIN DRIP SPECIES DIAMETER RADIUS la, lb 2211 15 White Cedar - Thuja Occidentalis 2 24" 16 White Cedar - Thuja Occidentalis 3 1611 14 White Cedar - Thuja Occidentalis 4 36" 20' Douglas Fir - Psuedotsu a Menziesii 5 28 " 1 18 Western White Pine - Pinus Monticola 6 38" 20 Red Cedar - Juniperis Vir iniana TREES 1a, 1b, AND 5 TO BE REMOVED PROPERTY SETBACKS SILT FENCE CLEARING LIMITS o -o Q TREE PROTECTION O O PER CITY of EDMONDSI, 2 DS = DOWN SPOUT FOOTNOTES: 1. SEE TEMPORARY PROTECTIVE TREE RQMNTS 2. TREES 1 a, 1 b, AND 5 TO BE REMOVED 8rITE PLAN - 22408 95th Place West z N O PROPERTY LOCATION - tth S11 SW 220th St SW l2utn St SW 2201h St S'N1' 2.20th St 5W 22Crt!,'- 10 �s O Y i b Westgate ro � •o a 4 p r p Elementary School19 rb �+ Nas Gorden The Hair J B Asphalt Paving s A a Zr 224th St SW 226th St SW 224th 51 SW 22408 95th Pl W, s Edmonds, WA 98020 8 � A 9 { {~ f5 � m a pf Lll>th $1 5;' a 2z5thPlsr� Cisco Electric t7' a o. 227th PI SA- 71 m 7 229111 st sw 228th Si Sw 228th St SW � � � Travelir. meth PI SWff rWeg2te chapel i FwWalgreens -l❑rug slore ,.\19 Sequoyah Condominiums Woodway Estates ��- _ - ---- - -" South County --Bucatini - Fire Station 209 n n m` 231st $,yw 23191 W Go - gl� 6o repass Apartments N A TEMPORARY PROTECTIVE TREE RQMNTS Protective Barrier. Before development, land clearing, grading, filling or any land alteration, the applicant shall: 1. Erect and maintain readily visible temporary protective tree fencing along the limits of disturbance which completely surrounds the protected area of all retained trees, groups of trees, vegetation and native soil. Tree protective fencing shall be a minimum height of three feet, visible and of durable construction; orange polyethylene laminar fencing is acceptable. 2. Install highly visible signs spaced no further than 15 feet apart along the entirety of the protective tree fencing. Said sign must be approved by the director and shall state, at a minimum, "Tree and Soil Protection Area, Entrance Prohibited," and provide the city phone number for code enforcement to report violations. 3. Prohibit excavation or compaction of soil or other potentially damaging activities within the barriers; provided, that the director may allow such activities approved by a qualified professional and under the supervision of a qualified professional retained and paid for by the applicant. 4. Maintain the protective barriers in place for the duration of the project until the director authorizes their removal. 5. Ensure that any approved landscaping done in the protected zone subsequent to the removal of the barriers shall be accomplished with machinery from outside the protected zone or by hand. 6. Limit the time period that the critical root zone is covered by mulch, plywood, steel plates or similar materials, or by light soils, to protect the tree's critical root zone. 7. In addition to the above, the director may require the following: a. If equipment is authorized to operate within the protected zone, the soil and critical root zone of a tree must be covered with mulch to a depth of at least six inches or with plywood, steel plates or similar material in order to protect roots and soil from damage caused by heavy equipment. b. Minimize root damage by hand -excavating a two -foot -deep trench, at edge of critical root zone, to cleanly sever the roots of trees to be retained. Never rip or shred roots with heavy equipment. C. Corrective pruning performed on protected trees in order to avoid damage from machinery or building activity. d. Maintenance of trees throughout construction period by watering and fertilizing. VICINITY MAP NO SCALE GENERAL NOTES: 1. ELECTRICAL DESIGN BY OWNER/BUILDER & PERMITS BY OWNER/ELECTRICAL CONTRACTOR MECHANICAL DESIGN BY OWNER/BUILDER & PERMITS BY OWNER/MECHANICAL CONTRACTOR. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES, ORDINANCES, AND REGULATIONS. 3. DO NOT SCALE DIMENSIONS FROM DRAWINGS. USE CALCULATED DIMENSIONS ONLY. NOTIFY THE ENGINEER OF RECORD IMMEDIATELY IF CONFLICTS EXIST. 4. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS, INCLUDING ASSUMPTIONS MADE ABOUT EXISTING FRAMING, BEFORE PROCEEDING WITH THE WORK. DISCREPANCIES, IF ANY,ARE TO BE REFERRED TO THE ENGINEER FOR DIRECTION PRIOR TO PROCEEDING WITH RELATED WORK. 5. VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT FIXTURES AND OTHER ITEMS. PROVIDE ALL BUCK -OUTS, BLOCKING, BACKING AND JACKS REQUIRED FOR INSTALLATION. 6. VERIFY LOCATIONS OF ALL EXISTING UTILITIES: CAP, MARK, AND PROTECT AS NECESSARY TO COMPLETE THE WORK. 7. THE OWNER/CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW OF ELECTRICAL DESIGNS AND FOR COORDINATING WITH OWNER/ELECTRICAL CONTRACTORS BEYOND THAT DESCRIBED IN THE PERMIT DOCUMENTS. 8. THE OWNER/CONTRACTOR SHALL CONSULT DRAWINGS AND OTHER DOCUMENTS OF ALL TRADES FOR ALL OPENINGS REQUIRED FOR THE CONSTRUCTION AND INSTALLATION OF DUCTS, PIPES, CONDUITS, EQUIPMENT, FIXTURES, AND CABINETS, AND SHALL VERIFY SIZE AND LOCATION. 9. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS, AND ANY PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS. 10. ALL CONTRACTOR INSTALLED ITEMS SHALL BE SUPPLIED WITH MECHANICAL AND ELECTRICAL SERVICES AS NECESSARY TO PROVIDE FOR THE FULL OPERATION OF THE ITEMS INSTALLED. 11. CONTRACTOR IS RESPONSIBLE FOR ENSURING ADEQUATE WATER PROOFING AND BUILDING ENVELOPE PROTECTION PER DRAWINGS WHERE SPECIFICALLY INDICATED AND PER CURRENT STANDARDS OF RESIDENTIAL CONSTRUCTION OTHERWISE. 12. SLIDING GLASS DOORS AND GLAZING WITHIN 18" OF FLOOR TO HAVE SAFETY GLAZING, LAMINATED OR TEMPERED GLASS. 13. FIRE WARNING SYSTEMS: EVERY DWELLING SHALL BE PROVIDED WITH APPROVED DETECTORS OF PRODUCTS OF COMBUSTION OTHER THAT HEAT, MOUNTED ON THE CEILING OR WALL AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR WALL AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREAS GIVING ACCESS TO ROOMS USED FOR SLEEPING PURPOSES AND IN EACH SLEEPING ROOM AS REQUIRED BY THE BUILDING OFFICIAL. 14. SMOKE DETECTORS SHALL BE INTERCONNECTED TO A DEVICE AUDIBLE IN SLEEPING AREAS AND SHALL BE POWERED BY THE BUILDING WIRING. 15. ALL NEW INTERIOR WALLS SHALL BE 2x4 @ 16" O.C. U.N.O. SEPARATE PERMITS REQUIRED FOR: • -ELECTRICAL • -PLUMBING • -MECHANICAL • -FURNACE • -SEWER 23. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED OR HAVE NATURAL RESISTANCE TO DECAY. 24. ALL FOOTINGS SHALL BE MIN. 18" BELOW GRADE, RESTING ON FIRM, UNDISTURBED EARTH OR COMPACTED FILL. OWNER and SITE Marc and Helen Guzman 22408 95th Place West Edmonds, Washington 98020-4522 ADDRESS SNOHOMISH COUNTY PARCEL # 005443000008001 LEGAL DESCRIPTION Section 25 Township 27 Range 3 Quarter SE PINECREST BLK 000 D-01 LOT 1 OF CITY OF EDM SP NO S-97-50 REC AF NO 9709040257 BEING A PTN OF LOT 80 EXST PLAT LOT COVERAGE and AREA EXISTING RESIDENCE 1056 SQFT EXISTING GARAGE 216 SQFT TOTAL: LOT SIZE: LOT COVERAGE: 1272 / 8038 = 15.8% SCOPE of WOR 1272 SQFT 8038 SQFT, 0.18 ACRES BUILD NEW GARAGE 12' x 18' BUILDING CODE and ZONING BUILDING CODE: 2018 INTERNATIONAL BUILDING CODE (2018 INTERNATIONAL RESIDENTIAL CODE with CITY of EDMONDS AMENDMENTS) DESIGN CRITERIA: PER SRC SEC. R301 DESIGN LOAD CRITERIA: NOT APPLICABLE - NO CHANGE TO EXIST'G CONSTRUCTION TYPE: VB (NON -RATED) OCCUPANCY TYPE: R-3; SINGLE FAMILY RESIDENCE ZONING: RS-8 - Single Family, 8,000 SQFT lots, Maximum Ht = 25.0' ENERGY CODE 2018 WASHINGTON STATE ENERGY CODE PRESCRIPTIVE REQUIREMENT APPROACH FOR SINGLE FAMILY RESIDENTIAL ADDITION/REMODEL < 500 SQFT 0 SQUARE FOOT ADDITION TO THE EXISTING RESIDENCE, REMODEL WITHIN EXISTING FOOT PRINT - 0.0 ENERGY CREDITS REQUIRED. PROJECT TEAM ENGINEERING: sliderule engineering works 227 'e' street southeast auburn, Washington 98002 CONTACT: Andrew Herrick PHONE: 206.380.0732 E-MAIL: alhpe-sliderule@q.com GENERAL CONTRACTOR: King's Remodeling, LLC. 5051 Southeast Mile Hill Road Port Orchard, Washington 98366 LICENSE NUMBER: KINGSRL885LJ WA UBI NUMBER: 603 188 983 CONTACT: Moises Reyes PHONE: 425.274.6124 EMAIL: reyes7094@gmail.com DRAWING INDEX A1.1 SITE PLAN AND NOTES A2.1 ARCHITECTURAL PLANS w/ DETAILS A3.1 ELEVATIONS S1.1 STRUCTURAL NOTES AND DETAILS �r `� 33083 �ex;tNAL �F3 TERE9 ��� �'ti 01.22 Bslide rule engineering works, 11c 227 'e' street southeast auburn, washington 98002 t= 206 + 380 + 0732 email = alhpe_sliderule@q.com O U n CD C "Cf) IZ - can 0 Ocn 0 N N E W PROJECT MANAGER: AH DRAWN BY: alh E: 07.07.22 QPLAN REVIEW COMMENTS 07.07.22 I m F RESUB Jul 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Site Plan, Vicinity Map and Project Information A1,1 CALL BEFORE YOU DIG: 1-800-424-5555 EXIST'G RESIDENCE (no work) Finish Floor = 379.32' 44'-0" x 24'-0" 2 NEW 4" CONCRETE SLAB ON GRADE W/ #3 REINFORCING BAR AT CL SLAB SPACED AT 12" OC _ 5/A2.1 EACH WAY Qiy�,B ,�Opti� UNLESS NOTED OTHERWISE, NAILING SHALL TOP PLATES CONFORM TO IBC TABLE 2304.9.1. HEADER PER PLAN (TYP) 1/2" STR1 PLYWOOD IT HID END NAIL' O- III I: •I 16d( ) PANEL EDGE — — •II II I. — •I — — II II 8d AT 12" I' I;I 'I I'I :•I II II I'I AT FIELD 8d at 4" OC AT I::I PANEL EDGES III II II II I; •I I SILL PLATE DISTRIBUTE EDGE NAIL SPC'G EQUALLY OVER ALL BUNDLE I'.I STUDS (TYP.) J— — L — — — — L - HOLDOWN PER 4/A2.1 SOLID BLOCKING LAID FLAT, MATCH STUD SIZE AT ALL PANEL EDGES, (TYP.) TYPICAL FRAMED WALL ELEVATION � J not to scale 4" SLAB w/ #3 @ 12" OC 1/8" x 1-1/2" PREMOLDED CONT. MASTIC JOINT STRIP. EW at CL SLAB (TYP.) (JOINT MAY BE SAW -CUT AT CONTRACTOR'S OPTION) L 10 MIL PLASTIC VAPOR BARRIER & COMPACTED STOP REBAR AT JOINT GRANULAR FILL, (TYP.) CONTROL JOINT PROVIDE CONTROL IN SLABS ON GRADE TO BREAK UP SLAB INTO RECTANGULAR AREAS OF 200 SQUARE FEET OR LESS. AREAS TO BE APPROX. SQUARE AND HAVE NO ACUTE ANGLES. CV 'd E 18'-0" O INGLE CAR GARAGE &DGE FLOOR ELEV = 380.0' 12 -0" x 18'-0" 1/8:12 SLOPE CONTROL JOINT PER 2/A2.1 (TYP) '< CR z Foundation Plan scale: 1/4" = V-0" NAILED SPLICE ol — KING AND TRIMMER 10d @ 12"o.c. STUD PER PLAN, OUTSIDE OF (TYP.) SPLICE (TYP) 2x HF#2 PLATE JOINT IN LOWER PLATE @ STUD . , u.Id SINGLE-xAT WINDO I L SIMPSO 4 AT 2x4, FC6 x6, (TYP.) FASTENER SIZE & SPACING PER SHEARWALL SCHED (2) 2x4 HORIZ. BLOCK EVENLY SPACED INTERSECTING WALL CORNER BARS TO MATCH EXTERIOR HORIZ. REINF. D p D D ADDITIONAL .1'-6" PLAN NOTES: (SEE SHEETS A1.1 FOR ADDITIONAL NOTES) 1. CONTRACTOR SHALL VERIFY ALL NOTES, DIMENSIONS & CONDITIONS PRIOR TO CONSTRUCTION. 2. EXTERIOR GARAGE WALLS TO BE 2x4 STUDS @ 16" OC PER 1/A2.1 (UNO) 3. PROVIDE FIRE BLOCKING @ LOCATIONS PER IRC SEC R302.11 4. ALL CONNECTORS BY SIMPSON STRONG -TIE INSTALL PER MANUFACTURER'S SPECIFICATIONS. 5. MINIMUM PROTECTION REQUIRED FOR BOLTS, NAILS, AND METAL CONNECTORS IN CONTACT WITH TREATED MATERIAL SHALL MEET THE MINIMUM REQUIREMENTS: TRIPLE ZINC ZMAX (G185 ASTM A653) FOR METAL PLATES, HOT DIP GALVANIZE (ASTM A123 FOR CONNECTORS AND ASTM 152 FOR FASTENERS AND ANCHORS). 6. ALL EXISTING FOOTINGS MIN 18" BELOW GRADE ON FIRM BEARING SOIL. —.------ -- -----. ------- II II II u EXIST'G RESIDENCE (no work) n Finish Floor = 379.32' II r . 44'-0" x 24'-0" I II JI I I II II II �I II Ii II I I I I . I. I . I . .I LEGEND ■ COLUMN ORIGINATES OR CONTINUES ❑ COLUMN BELOW WALL BELOW WIND OW SCHED ULE WINDOW MARK UNIT SIZE TYPE FRAME MTL GLAZING MIN "U" MFR MODEL NOMINAL HEAD HT QTY REMARKS WIDTH x HEIGHT OA 4'-0" x V-6" CASEMENT WOOD w/ METAL CLADDING INSULATED LOW E II 0.30 OWNER SELECT 6-8" 2 GARAGE PV = FROST OR PRIVACY GLASS EG = EGRESS VERIFY ROUGH OPENINGS AND SIZES SG = SAFETY GLASS DOOR SC HEDULE DOOR MARK UNIT SIZE WIDTH x HEIGHT TYPE MIN. "U" LOCATION QUANTITY REMARKS 0 3'-0" x 6'-8" SOLID EXTERIOR OD DOOR, EXEMPT EXTERIOR DOOR 1 OWNER SELECT 0 8' 0" x 7'-0" OVERHEAD GARAGE DOOR EXEMPT GARAGE 1 OWNER SELECT VERIFY ROUGH OPENINGS AND SIZES 4'-0" SPLICE (TYP) (2) ROWS 10d NAILS 11 AT 2" OC, STAGGER JOINT IN UPPER LAYOUT, (24) NAILS TOTAL PLATE @ STUD NAILED SPLICE DETAIL DOUBLE TOP PLATE PER NAILED SPLICE DETAIL HDR PER PLAN SET TOWARDS OUTSIDE OF WALL FLUSH W/EXT SURFACE OF STUD 2x SECTION AT HEADER CORNER BARS TO MATCH CROSS WALL HORIZ. REIiNF. (ALT. HOOKS) p D.. p 0 o. VERT. BARS CROSS WALL TYP CORNER BAR ARRN G (2) STUDS (TYP) SILL PLATE & AB'S - SEE SHEARWALL 3CHEDULE ADDED STUD IF COUNTER-SINK'G 7" E BED INTO OF BOLT HEADS CO CRETE (TYP) IS REQ'D (2) 3/4" DIA I: t SIMPSON HD513 4" MIN A307 5/8" DIA HILTI 04 HY-150 EPDXY ANCHO TOP OF STEM EDGE OF STEM ELEVATION INTERSECTING WALL 16d @ 8" OC, STGR SIMPSON HD5B W/ (2) 3/4" DIA BOLTS, TO 5/8" DIA A307 HILTI HY-150 EDGE NAIL'G (TYP, UNO) SHEARWALL NOTES: 1. SEE PLAN FOR HOLDOWN LOCATION. 2. INSTALL PER SIMPSON STRONG TIE SPECIFICATIONS. HD5B HOLDOWN DETAIL co j(2) 2x8 (2) 2x8 O o II co Uj II II U) 1:t Of 5/8" APA RATED c 24/16 SHT'G. NAIL 2E N W/ 8d @ 4" OC Of EDGES 12" OC FIELD, PROVIDE 2/S1.1 LL_ ________ _�212x8 _ _-- J� PLY CLIPS AT UNSUPPORTED EDGES /U) z Roof Framing Plan scale: 1/4" = V-0" IT (2) #4 CONT. SLAB ON GRADE PER PLAN #3 30" @ 18"o.c. co F o O III -III D 3/A2.1 co z _ (2) #4 CONT. _ OQ. I III=III_ BEAR FTG. ON FIRM EQ 6" EQ #4 @ 12"OC HORIZ & #4 @ UNDISTURBED SOIL 1'-211 TUC VERT, ALT LEG 04 EXTERIOR FTG at OPENING 3/4"=1'-0" #4 @ 12"OC, EW— ALT VERT BAR LEG Q (2) #4 CONT .----- Q 6" EXTERIOR F007G AB PER 1/A2.1 (2) #4 CONT. SLAB ON GRADE PER PLAN BEAR FTG. ON FIRM UNDISTURBED SOIL Z.22 Bslide rule engineering works, llc 227 'e' street southeast auburn, washington 98002 t= 206 + 380 + 0732 emaii = alhpe—sliderule@q.com O U n O 0) o Cn E O N N 0 N E � w PROJECT MANAGER. AH DRAWN BY: alh 07.07.22 QPLAN REVIEW COMMENTS 07.07.22 I— I— L�J m RESUB Jul 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Existing and Proposed Floor Plans w/ Details 314" =1'-0" 314"=1'-0" not to scale 314"=1'-0" A2, 1 RS-8 MAX HEIGHT 2_5.0' 404.88' Ir' AVERAGE HEIGHT CALCULATIONS 379.88' + 379.88' + 379.88' + 379.88' = 379.88' 4 Maximum Height = 25.0' (RS-8) Maximum Elevation = 404.88' Proposed Ridge Elevation = 390.83' < 404.88' A CONTINUOUS RIDGE VENT TYP TOP OF RIDGE 390_.83' � �7 12 12 METAL DRIP N 4 a 4 EDGE (TYP) NEW TOP PLATE 388.33' — — — — — — — — — — 1x PAINTED 1x PAINTED FASCIA (TYP) FASCIA (TYP) C V-6" � 2 MAX PAINTED 6" BEVEL PAINTED 6" BEVEL SIDING (TYP) SIDING (TYP) C Q FINISH FLOOR 380.00' FINISH GRADE FINISH GRADE 379.88' rJ �� L South Elevation scale: 1/4" = V-0" HEIGHT CALCULATIONS L - - - J L - - - J CONTINUOUS RIDGE VENT ( ❑0 0 11 LA___ ____ ___ NEW 3068 DOOR West Elevation scale: 1/4" = V-0" 1. VERIFY SHEAR WALL NAILING & HOLDOWNS PER PLAN & SCHEDULE PRIOR TO INSTALLING SIDING. 2. THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED & WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. PROVIDE INFILTRATION CONTROL @ WINDOW & DOOR FRAMES AND PENETRATIONS & OPENINGS AT WALLS, FLOORS & ROOFS. 3. PROVIDE GALVANIZED OR ANODIZED SHEET METAL FLASHING & COUNTER FLASHING AT ALL ROOF PENETRATIONS, CHIMNEYS, & SKYLIGHTS PER IRC SEC. R905. 4. PROVIDE ROOF COVERING PER IRC SEC. R905. -INSTALL PER MFR'S SPECS. 5. PROVIDE EXTERIOR WALL COVERING PER IRC SEC. R703. 6. PROVIDE CONTINUOUS GUTTERS & DOWNSPOUTS @ ALL EAVES, TYP. 7. SITE SHALL BE GRADED & HARD SURFACES SLOPED, SO AS TO DRAIN SURFACE WATER AWAY FROM BUILDING. 1'-6" MAX rJ �� FINISH GRADE L --- J RS-8 MAX HEIGHT 25.0' I-F A 404.88' CONTINUOUS CONTINUOUS Q RIDGE VENT (TYP) RIDGE VENT (TYP) TOP OF RIDGE 390.83' METAL DRIP 12 12 EDGE (TYP) 4 �a 4 `? — — — \ — — — — CV NEW TOP PLATE 388.33' — - 1x PAINTED FASCIA (TYP) 1x PAINTED FASCIA (TYP) 1'-611 MAX PAINTED 6" BEVEL MAX PAINTED 6" oO SIDING (TYP) BEVEL SIDING 1 = _ (TYP) — FINISH FLOOR 380.00' — FINISH GRA rJ �� rJ �� FINISH GRADE 379.88' r1 rJ FINISH GRADE L - - - J L - - - J L - - - J L.___J A3, 1 East Elevation scale: 1/4" = V-0" EXTERIOR ELEVATION NOTES: (SEE SHEETS A1.1 and S1.1 FOR ADDITIONAL NOTES) 1. VERIFY SHEAR WALL NAILING & HOLDOWNS PER PLAN & SCHEDULE PRIOR TO INSTALLING SIDING. 2. THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED & WEATHERSTRIPPED TO LIMIT AIR LEAKAGE. PROVIDE INFILTRATION CONTROL @ WINDOW & DOOR FRAMES AND PENETRATIONS & OPENINGS AT WALLS, FLOORS & ROOFS. 3. PROVIDE GALVANIZED OR ANODIZED SHEET METAL FLASHING & COUNTER FLASHING AT ALL ROOF PENETRATIONS, CHIMNEYS, & SKYLIGHTS PER IRC SEC. R905. 4. PROVIDE ROOF COVERING PER IRC SEC. R905. -INSTALL PER MFR'S SPECS. 5. PROVIDE EXTERIOR WALL COVERING PER IRC SEC. R703. 6. PROVIDE CONTINUOUS GUTTERS & DOWNSPOUTS @ ALL EAVES, TYP. 7. SITE SHALL BE GRADED & HARD SURFACES SLOPED, SO AS TO DRAIN SURFACE WATER AWAY FROM BUILDING. North Elevation scale: 1/4" = V-0" WINDOW SCHEDULE WINDOW MARK UNIT SIZE TYPE FRAME MTL GLAZING MIN "U" MFR MODEL NOMINAL HEAD HT QTY REMARKS WIDTH x HEIGHT OA 4'-0" x V-6" CASEMENT WOOD w/ METAL CLADDING INSULATED LOW E II 0.30 OWNER SELECT 6'-8" 2 GARAGE PV = FROST OR PRIVACY GLASS EG = EGRESS VERIFY ROUGH OPENINGS AND SIZES SG = SAFETY GLASS DOOR SCHEDULE DOOR MARK UNIT SIZE WIDTH x HEIGHT TYPE MIN. "U" LOCATION QUANTITY REMARKS 1U 3'-0" x 6'-8" SOLID ER OROD DOOR, EXEMPT EXTERIOR DOOR 1 OWNER SELECT 2U 8'-0" x 7'-0" OVERHEAD GARAGE DOOR EXEMPT GARAGE 1 OWNER SELECT VERIFY ROUGH OPENINGS AND SIZES �r Z-22 Bslide rule engineering works, llc 227 'e' street southeast auburn, washington 98002 t= 206 + 380 + 0732 email = alhpe_sliderule@q.com 0 Q� N U n CD C o •� C .� can E O 0 CINIJ N � W PROJECT MANAGER. AH DRAWN BY: alh 07.07.22 APLAN REVIEW COMMENTS 07.07.22 i— W m C� RESUB Jul 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Garage Elevations GENERAL STRUCTURAL NOTES WOOD (The following apply unless shown otherwise on the plans) CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE 2018 INTERNATIONAL BUILDING CODE (IBC 2018 EDITION). 2. DESIGN LOADING CRITERIA ROOF LIVE LOAD ......................... 25 PSF (SNOW) FLOOR LIVE LOAD (RESIDENTIAL) ................. 40 PSF BASIC WIND SPEED (3-SEC GUST) ... 110 MPH, MRI 50YR = 85 MPH, EXPOSURE B, Kzt = 1.3, 1 = 1.0 SEISMIC ............................... SITE CLASS "D", R=6.0, Ss=1.225, S1=0.421, I = 1.0 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 5. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. GEOTECHNICAL 7. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH AT LEAST 18" BELOW ADJACENT FINISHED GRADE. UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. ALL VALUES ARE ASSUMED. ASSUMED ALLOWABLE SOIL PRESSURE............................1500 PSF CONCRETE 8. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH IBC SECTION 1905 AND ACI 301. CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF f'c=3000 PSI (FOR WEATHERING PURPOSES AND NOT STRENTH, MIN 2,500 PSI FOR STRENGTH) AND MIX SHALL HAVE A MAXIMUM ABSOLUTE WATER: CEMENT RATIO OF 0.58 FOR NON -AIR ENTRAINED CONCRETE AND 0.46 FOR AIR -ENTRAINED CONCRETE CONCRETE SHALL BE PROPORTIONED TO PRODUCE A SLUMP OF 5" OR LESS. AIR ENTRAINED CONCRETE SHALL BE USED AT ALL EXTERIOR AND UNHEATED EXPOSURES. THE MINIMUM AMOUNTS OF CEMENT AND MAXIMUM AMOUNTS OF WATER MAY BE CHANGED IF A CONCRETE PERFORMANCE MIX IS SUBMITTED TO THE STRUCTURAL ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE. THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE AMOUNTS OF CEMENT, FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER CEMENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH SBC 1905.3. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY FOR SPECIFIED PERFORMANCE. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND C618. TOTAL AIR CONTENT FOR FROST -RESISTANT CONCRETE SHALL BE IN ACCORDANCE WITH TABLE 1904.2.1 OF INTERNATIONAL BUILDING CODE. CEMENT CONTENT MAY BE REDUCED 15% - 25% BY VOLUME AND REPLACED WITH FLY ASH SHALL NOT MAKE UP MORE THAN 35% OF THE TOTAL CEMENTITIOUS CONTENT. FLY ASH SHALL COMPLY WITH ASTM C618 OR AASHTO M295. 9. A MINIMUM OF 80% OF REINFORCING STEEL SHALL COME FROM RECYCLED MATERIALS. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, Fy=60,000 PSI. EXCEPTIONS: ANY BARS #5 AND SMALLER CAN BE GRADE 40, Fy=40,000 PSI. 10. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 315 AND 318. LAP ALL CONTINUOUS REINFORCEMENT #5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 40 BAR DIAMETERS OR 2'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACI 318, CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 11. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE IN ACCORDANCE WITH IBC SECTION 1907.7. FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ................................ 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER)... 2" (#5 BARS OR SMALLER) ........................ 1-1/2" SLABS AND WALLS (INT. FACE) .... GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4" 12. FRAMING LUMBER SHALL BE KILN DRIED OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 16. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: 2x MEMBERS: HEM -FIR #2 OR BETTER 2x STUDS AND PLATES: HEM -FIR STUD GRADE OR BETTER 13. STRUCTURAL WOOD PANEL SHEATHING (PLYWOOD) SHALL BE APA RATED PANELS WITH EXPOSURE 1 CLASSIFICATION. ROOF SHEATHING SHALL BE 5/8" (NOMINAL) WITH SPAN RATING 24/16. WALL SHEATHING SHALL BE 1/2" WITH SPAN RATING 24/0. REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS. 14. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF 15# ASPHALT IMPREGNATED BUILDING PAPER OR ONE LAYER OF 30# ASPHALT IMPREGNATED BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR MASONRY. 15. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C-2022. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICBO APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTNERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. 16. WOOD FASTENERS A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER EQUIV STAPLE MIN LENGTH 8d 2-1/2" 0.131 " 13 GA. 1-3/4" 10d 3" 0.148" 12 GA. 1-3/4" 16d 3-1/2" 0.162" NO EQUIV NO EQUIV IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS OR STAPLES, SHALL BE SUBMIT NAIL SPECIFICATIONS TO THE ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. B. NAILS AND STAPLES - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. 20. PREFABRICATED CONNECTOR PLATE WOOD ROOF TRUSSES SHALL BE DESIGNED BY THE MANUFACTURER IN ACCORDANCE WITH THE "DESIGN SPECIFICATION FOR METAL PLATE CONNECTED WOOD TRUSSES, TPI-78" BY THE TRUSS PLATE INSTITUTE FOR THE SPANS AND CONDITIONS SHOWN ON THE PLANS. LOADING SHALL BE AS FOLLOWS: TOP CHORD LIVE LOAD TOP CHORD DEAD LOAD BOTTOM CHORD DEAD LOAD BOTTOM CHORD LIVE LOAD TOTALLOAD WIND UPLIFT (TOP CHORD) 25 PSF 10 PSF 5 PSF 5 PSF (not concurrant with top chord) 40 PSF 5 PSF (GROSS) WOOD TRUSSES SHALL UTILIZE APPROVED CONNECTOR PLATES (GANGNAIL OR EQUAL). SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS TO THE ARCHITECT AND ENGINEER FOR REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS SHALL BEAR THE STAMP AND SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON. PROVIDE FOR SHAPES, BEARING POINTS, INTERSECTIONS, HIPS, VALLEYS, ETC., SHOWN ON THE DRAWINGS. EXACT COMPOSITION OF SPECIAL HIP, VALLEY, AND INTERSECTION AREAS (USE OF GIRDER TRUSSES, JACK TRUSSES, STEP-DOWN TRUSSES, ETC.) SHALL BE DETERMINED BY THE MANUFACTURER UNLESS SPECIFICALLY INDICATED ON THE PLANS. PROVIDE ALL TRUSS TO TRUSS AND TRUSS TO GIRDER TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. PROVIDE FOR ALL TEMPORARY AND PERMANENT TRUSS BRACING AND BRIDGING. 21. WOOD FRAMING NOTES -THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.9.1 OF THE IBC. UNLESS OTHERWISE NOTED, ALL NAILS SHALL BE COMMON. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. B. WALL FRAMING: ALL NEW STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE 2x4 STUDS @ 16" O.C. AT EXTERIOR WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS. TWO 2x8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED. ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO 16d NAILS, AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16d NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16d @ 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE SIX 16d NAILS @ 4" O.C. EACH SIDE JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS @ 12" O.C. STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS (WITH 7" MINIMUM EMBEDMENT) @ 4'-0" O.C. UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16d @ 12" O.C. STAGGERED. REFER TO THE PLANS AND SHEARWALL SCHEDULE FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED, PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND BOTTOM PLATES, AND BLOCKING WITH NAILS @ 7" O.C. USE 5d COOLER NAILS OR 1/2" GWB AND 6d COOLER NAILS FOR 5/8" GWB. PROVIDE 1/2" (NOMINAL) APA RATED SHEATHING (SPAN RATING 24/0) ON EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UN -SUPPORTED EDGES), AND TOP AND BOTTOM PLATES WITH 8d @ 6"O.C. AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8d @ 12" O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS. C. ROOF FRAMING: UNLESS OTHERWISE NOTED ON THE PLANS, PLYWOOD ROOF SHEATHING SHALL BE LAID UP WITH GRAIN PERPENDICULAR TO SUPPORTS AND NAILED WITH 8d NAILS @ 6" O.C. TO FRAMED PANEL EDGES AND OVER STUD WALLS AS SHOWN ON PLANS AND @ 12" O.C. TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOFSHEATHING EDGES. ALLOW 1/81, SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING. 2x VENT BLK'G W/ (3) 2"0 VENT HOLES EVENLY SPACED AND SCREENED A-35 @ 24" OC ROOFEDGE NAILING (2) 16D FASCIA TO TRUSS 2x FASCIA SHEAR WALL PER 1/A2.1 EDGE NAIL'G PRE -MANUFACTURED TRUSS PER PLAN SIMPSON H2.5 X DOUBLE TOP PLATE - PER 1/A2.1 HDR PER PLAN TYPICAL TRUSS to WALL 3/4"=1' 0" 2'-0" MAX. (2) 10d FASCIA TO TRUSS SHEARWALL EDGE NAILING PER PLAN AND SCHED, (TYP.) LOAD BEAR'G GABLE TRUSS 16d @ 8"o.c. BOT. CHORD GABLE TRUSS TO 2x BLKG. SHEATH PER PLAN AND SHEARWALL SCHEDULE 2'-0" ROOF SHT'G, EDGE NAILING, (TYP.) (2) 16d TOP CHORD TRUSS TO 2x (TYP) 2x BLKG @ 4'-0" OC TRUSS PER PLAN (2) 16d BOT. CHORD TRUSS TO 2x BLKG. DBL 2x TOP R PER 1/A2.1 TYPICAL GABLE END FRAMING 3/4"=1'-0" L. �r `� 33083 �ex;tNAL ISTE$F 01.22 Bslide rule engineering works, llc 227 'e' street southeast auburn, washington 98002 t= 206 + 380 + 0732 email - alhpe_sliderule@q.com U .Cf) E N 0 cn o0 N � U 0 cn LC7 0 06 00 cn N 0 N E W PROJECT MANAGER. AH DRAWN BY: alh 07.07.22 QPLAN REVIEW COMMENTS 07.07.22 RESUB Jul 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Structural Notes and Details Si'l