Loading...
APPROVED PLN ENG BLD2022-0691+SITE PLAN+7.11.2022_12.54.53_PM+2981179SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM 1 I .T 114 VV VV L/ V VI n �25.37' -N 0011. ° 35' 27" W - I I 0 1 PROPERTY- SETBACKS - - - - - - - - - - I I I I I SNOHOMISH COUNTY APN: 00544300008001 j EXIST'G 8038 SQFT I REAR PATIO I I I I I � I I 00 I I 8 0 I I 00 EXISTING00 I I I RESIDENCE Z GAS METER FF = 379.32' o I 1056 SQFT I o I I -- �- 11 I ELEC METER O j� 7 -6 I RIDGE 390.83 I I I WALL TOP PLATE 388.33' I 8.15' x 16.5' MIN CLEAN 18'-011 PJ RKING OUT t oO° AEA (TYP) o -- - - - - XIIj 71_611 x x NEW GARAGE Q5 cP x F F = 3 x O GRAVEL xxI xx x�*x x xx�x xA*� xxxx*x xx� Xx,XI x * \ `xl 216 SQFT PARKING x xx*xx�X* / X*Y. AREA x xx X L x -*- �x O O - S W/ SPLASH BLO (TYP) W LU x x + H W x x cnCn IxXx `dP+ > UJ IL cn O Y. W LU x U x Q 2 ® 4 67.4 N 00 06 37 G TREE DRIP CIRCLE (TYP) WATER- L ETER LJ GAS MAIN SEWER MAIN I 95th Place West LEGEND AVERAGE HEIGHT CALCULATIONS 379.88' + 379.88' + 379.88' + 379.88' = 379.88' 0 4 Maximum Height = 25.0' Maximum Elevation = 404.88' Proposed Ridge Elevation = 390.83' < 404.88' 00 L0 ao 00 Z r` c� APPROVED BY PLANNING Jul 19 2022 SIGNIFICANT TREES ID TRUNK RAIN DRIP SPECIES DIAMETER RADIUS la, lb 2211 1 15 White Cedar - Thuja Occidentalis 2 24" 16 White Cedar - Thuja Occidentalis 3 1611 1 14 White Cedar - Thuja Occidentalis 4 3611 20' Douglas Fir - Psuedotsu a Menziesii 5 28" 181 Western White Pine - Pinus Monticola 6 38" 201 Red Cedar - Juniperis Vir iniana TREES 1a, 1b, AND 5 TO BE REMOVED PROPERTY SETBACKS SILT FENCE CLEARING LIMITS o -o 0 TREE PROTECTION O O PER CITY of EDMONDSI, 2 DS = DOWN SPOUT FOOTNOTES: 1. SEE TEMPORARY PROTECTIVE TREE RQMNTS 2. TREES 1 a, 1 b, AND 5 TO BE REMOVED 8rITE PLAN - 22408 95th Place West Z ADD GUTTERS/DOWNSPOUTS AND SPLASHBLOCKS PROPERTY LOCATION 220th St SW 220th St SW Lout i St ,,'u 2201h St S'1'1' 2.20th St 5W 220th `- 10 p �s OY i b Westgate � •o a � p r p Elementary School rb �+ Nas Gorden �, The Hair J B Asphalt Paving � A _ a 3 224th St SW 226th St SW 224th 51 SW 22408 95th PI W, Edmonds, WA 98020 8 � A 9 { {~ 13 m ar uGth �, 5; g 226thPlsrl Cisco Electric t7' a o. 227th PI SA- 71 m 7 220111 s1 sw 228th Si Sw 228th St SW Travelir meth PI sx' /�-We-slgate chapel > y � Walgreens _ Qrug store Sequoyah Condominiums YJoodway Estates 9 - -` South County --BucaIIni - \ Fire Station 20 n n 231 st 4sly 2319L = Go _ gle Compass Apartments N A TEMPORARY PROTECTIVE TREE RQMNTS Protective Barrier. Before development, land clearing, grading, filling or any land alteration, the applicant shall: 1. Erect and maintain readily visible temporary protective tree fencing along the limits of disturbance which completely surrounds the protected area of all retained trees, groups of trees, vegetation and native soil. Tree protective fencing shall be a minimum height of three feet, visible and of durable construction; orange polyethylene laminar fencing is acceptable. 2. Install highly visible signs spaced no further than 15 feet apart along the entirety of the protective tree fencing. Said sign must be approved by the director and shall state, at a minimum, "Tree and Soil Protection Area, Entrance Prohibited," and provide the city phone number for code enforcement to report violations. 3. Prohibit excavation or compaction of soil or other potentially damaging activities within the barriers; provided, that the director may allow such activities approved by a qualified professional and under the supervision of a qualified professional retained and paid for by the applicant. 4. Maintain the protective barriers in place for the duration of the project until the director authorizes their removal. 5. Ensure that any approved landscaping done in the protected zone subsequent to the removal of the barriers shall be accomplished with machinery from outside the protected zone O or by hand. 6. Limit the time period that the critical root zone is covered by mulch, plywood, steel plates or similar materials, or by light soils, to protect the tree's critical root zone. 7. In addition to the above, the director may require the following: a. If equipment is authorized to operate within the protected zone, the soil and critical root zone of a tree must be covered with mulch to a depth of at least six inches or with plywood, steel plates or similar material in order to protect roots and soil from damage caused by heavy equipment. b. Minimize root damage by hand -excavating a two -foot -deep trench, at edge of critical root zone, to cleanly sever the roots of trees to be retained. Never rip or shred roots with heavy equipment. C. Corrective pruning performed on protected trees in order to avoid damage from machinery or building activity. d. Maintenance of trees throughout construction period by watering and fertilizing. VICINITY MAP NO SCALE OWNER and SITE Marc and Helen Guzman 22408 95th Place West Edmonds, Washington 98020-4522 ADDRESS SNOHOMISH COUNTY PARCEL # 005443000008001 LEGAL DESCRIPTION Section 25 Township 27 Range 3 Quarter SE PINECREST BLK 000 D-01 LOT 1 OF CITY OF EDM SP NO S-97-50 REC AF NO 9709040257 BEING A PTN OF LOT 80 EXST PLAT LOT COVERAGE and AREA EXISTING RESIDENCE 1056 SQFT EXISTING GARAGE 216 SQFT TOTAL: 1272 SQFT LOT SIZE: 8038 SQFT, 0.18 ACRES LOT COVERAGE: 1272 / 8038 = 15.8% SCOPE of WORK BUILD NEW GARAGE 12' x 18' BUILDING CODE and ZONING BUILDING CODE: 2018 INTERNATIONAL BUILDING CODE (2018 INTERNATIONAL RESIDENTIAL CODE with CITY of EDMONDS AMENDMENTS) DESIGN CRITERIA: PER SRC SEC. R301 DESIGN LOAD CRITERIA: NOT APPLICABLE - NO CHANGE TO EXIST'G CONSTRUCTION TYPE: VB (NON -RATED) OCCUPANCY TYPE: R-3; SINGLE FAMILY RESIDENCE ZONING: RS-8 - Single Family, 8,000 SQFT lots, Maximum Ht = 25.0' ENERGY CODE GENERAL NOTES: 2018 WASHINGTON STATE ENERGY CODE 1. ELECTRICAL DESIGN BY OWNER/BUILDER & PERMITS BY PRESCRIPTIVE REQUIREMENT APPROACH FOR SINGLE FAMILY OWNER/ELECTRICAL CONTRACTOR MECHANICAL DESIGN BY RESIDENTIAL ADDITION/REMODEL < 500 SQFT OWNER/BUILDER & PERMITS BY OWNER/MECHANICAL CONTRACTOR. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND 0 SQUARE FOOT ADDITION TO THE EXISTING RESIDENCE, REMODEL MATERIALS IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES, WITHIN EXISTING FOOT PRINT - 0.0 ENERGY CREDITS REQUIRED. ORDINANCES, AND REGULATIONS. 3. DO NOT SCALE DIMENSIONS FROM DRAWINGS. USE CALCULATED PROJECT TEAM DIMENSIONS ONLY. NOTIFY THE ENGINEER OF RECORD IMMEDIATELY IF CONFLICTS EXIST. ENGINEERING: 4. CONTRACTOR SHALL VISIT JOB SITE AND VERIFY ALL DIMENSIONS AND sliderule engineering works EXISTING CONDITIONS, INCLUDING ASSUMPTIONS MADE ABOUT EXISTING 227'e' street southeast FRAMING, BEFORE PROCEEDING WITH THE WORK. DISCREPANCIES, IF auburn, Washington 98002 ANY,ARE TO BE REFERRED TO THE ENGINEER FOR DIRECTION PRIOR TO CONTACT: Andrew Herrick PROCEEDING WITH RELATED WORK. PHONE: 206.380.0732 5. VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT FIXTURES AND E-MAIL: alhpe-sliderule@q.com OTHER ITEMS. PROVIDE ALL BUCK -OUTS, BLOCKING, BACKING AND JACKS REQUIRED FOR INSTALLATION. GENERAL CONTRACTOR: 6. VERIFY LOCATIONS OF ALL EXISTING UTILITIES: CAP, MARK, AND Remodeling, PROTECT AS NECESSARY TO COMPLETE THE WORK. 5051 Hill 5051 Southeast Mile Hill Road 7. THE OWNER/CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW OF Port Orchard, Washington 9 8366 ELECTRICAL DESIGNS AND FOR COORDINATING WITH OWNER/ELECTRICAL LICENSE NUMBER: RL8 85LJ CONTRACTORS BEYOND THAT DESCRIBED IN THE PERMIT DOCUMENTS. WA UBI NUMBER: 603 188 88 983 8. THE OWNER/CONTRACTOR SHALL CONSULT DRAWINGS AND OTHER CONTACT: Moises Reyes DOCUMENTS OF ALL TRADES FOR ALL OPENINGS REQUIRED FOR THE PHONE: 4.6124 CONSTRUCTION AND INSTALLATION OF DUCTS, PIPES, CONDUITS, EMAIL: reyes?yes7094@gmail.com EQUIPMENT, FIXTURES, AND CABINETS, AND SHALL VERIFY SIZE AND LOCATION. 9. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS, AND ANY PENETRATING DUCTS, PIPES, CONDUIT, OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY MECHANICAL, ELECTRICAL, AND OTHER ITEMS. UTILITIES MAY REQUIRE A SEPERATE PERMIT. 10. ALL CONTRACTOR INSTALLED ITEMS SHALL BE SUPPLIED WITH MECHANICAL AND ELECTRICAL SERVICES AS NECESSARY TO PROVIDE FOR THE FULL OPERATION OF THE ITEMS INSTALLED. 11. CONTRACTOR IS RESPONSIBLE FOR ENSURING ADEQUATE WATER PROOFING AND BUILDING ENVELOPE PROTECTION PER DRAWINGS WHERE SPECIFICALLY INDICATED AND PER CURRENT STANDARDS OF RESIDENTIAL CONSTRUCTION OTHERWISE. 12. SLIDING GLASS DOORS AND GLAZING WITHIN 18" OF FLOOR TO HAVE SAFETY GLAZING, LAMINATED OR TEMPERED GLASS. 13. FIRE WARNING SYSTEMS: EVERY DWELLING SHALL BE PROVIDED WITH APPROVED DETECTORS OF PRODUCTS OF COMBUSTION OTHER THAT HEAT, MOUNTED ON THE CEILING OR WALL AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR WALL AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREAS GIVING ACCESS TO ROOMS USED FOR OWNER/CONTRACTOR IS RESPONSIBLE FOR SLEEPING PURPOSES AND IN EACH SLEEPING ROOM AS REQUIRED BY EROSION CONTROL AND DRAINAGE THE BUILDING OFFICIAL. 14. SMOKE DETECTORS SHALL BE INTERCONNECTED TO A DEVICE AUDIBLE IN SLEEPING AREAS AND SHALL BE POWERED BY THE BUILDING WIRING. 15. ALL NEW INTERIOR WALLS SHALL BE 2x4 @ 16" O.C. U.N.O. SEPARATE PERMITS REQUIRED FOR: • -ELECTRICAL Applicant shall repair/replace all ENGINEERING DIVISION • -PLUMBING damage to utilities or frontage APPROVED AS NOTED • -MECHANICAL improvements in City right-of-way per city standards that is caused or Jd/ W44U mt 07/12/2022 • -FURNACE occurs during the permitted project. VV • -SEWER 23. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED OR HAVE NATURAL RESISTANCE TO DECAY. 24. ALL FOOTINGS SHALL BE MIN. 18" BELOW GRADE, RESTING ON FIRM, UNDISTURBED EARTH OR COMPACTED FILL. --RS-8" Zone .------------- Corner Flag Setbacks: Required Actual 25 25 Front 7.5 Sides 15 15 Rear -:_-:_-:_-- ::------- Other . ' . ----- -. 15 : 10'10" Height •------------ •------- DRAWING INDEX A1.1 SITE PLAN AND NOTES A2.1 ARCHITECTURAL PLANS w/ DETAILS A3.1 ELEVATIONS S1.1 STRUCTURAL NOTES AND DETAILS 0, - n�l Fw �r `� 33083 �ex;tNAL �F3 TERE9 ��� �'ti 01.22 Bsliderule engineering works, 11c 227 'e' street southeast auburn, washington 98002 t= 206 + 380 + 0732 email = alhpe_sliderule@q.com O U n CD "Cf) C .� - Cn Ocn 0 N N E W PROJECT MANAGER: AH DRAWN BY: alh E: 07.07.22 QPLAN REVIEW COMMENTS 07.07.22 bld2022-0691 I m F RESUB Jul 11 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Site Plan, Vicinity Map and Project Information Al , 1