APPROVED BLD2023-0325+Structural_Plans+3.9.2023_5.11.26_PM+3412804GENERAL STRUCTURAL NOTES: (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS) 1. BASIS OF DESIGN: 1.1. BUILDING CODE & REFERENCE STANDARDS: ALL MATERIALS & WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF THE DRAWINGS, SPECIFICATIONS, & THE 2018 INTERNATIONAL BUILDING CODE. 1.2. STRUCTURAL DESIGN CRITERIA: ACTUAL DEAD LOADS PLUS THE FOLLOWING DEAD & LIVE LOADS: FLOOR LIVE LOAD: 40 PSF DECK LIVE LOAD: 60 PSF WIND LOADING: 100 MPH BASIC WIND SPEED; EXPOSURE "B"; IW = 1.0; KZT = 1.0; RISK CATEGORY - II SEISMIC DESIGN: EQUIVALENT STATIC FORCE PROCEDURE SS = 1.50, Fa = 1.0 S, = 0.5, FV = 1.8 SIDS = 1.0 IE = 1.0 SITE CLASS = "D" SEISMIC DESIGN CATEGORY = "D" RISK CATEGORY - II 2. CAST -IN -PLACE CONCRETE: 2.1. FOOTINGS: FOOTINGS SHALL BEAR ON SOLID UNYIELDING EARTH AT LEAST 18 INCHES BELOW LOWEST ADJACENT FINISHED GRADE AT PERIMETER AND EXTERIOR LOCATIONS. MINIMUM FOOTING WIDTH SHALL BE 18 INCHES. ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF MAXIMUM. 2.2. CONCRETE: NEW CONCRETE SHALL ATTAIN A 28 DAY STRENGTH OF 2500 PSI, MAXIMUM W/C RATIO = 0.45, MINIMUM 5-1/2 SACKS OF CEMENT PER CUBIC YARD. SUBMIT MIX DESIGN FOR REVIEW AND APPROVAL. 2.3. GROUT: 5000 PSI MINIMUM 7-DAY CURE STRENGTH PER ASTM C1157-00. GROUT TO BE PREMIXED NON -SHRINK "MASTERFLOW 928 GROUT" OR APPROVED EQUAL. USE SPECIFIC GROUT MIX RECOMMENDED BY MANUFACTURER FOR EACH GROUT APPLICATION & FOLLOW GROUT MANUFACTURER'S INSTRUCTIONS. 2.4. REINFORCING STEEL: NEW REINFORCING STEEL SHALL CONFORM TO ASTM A615 GRADE 60. SUBMIT REINFORCING SHOP DRAWINGS WITH DETAILS PER ACI 315 MANUAL OF STANDARD PRACTICE. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WITH ACI 318-14. LAP ALL CONTINUOUS REINFORCEMENT 40 BARS DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS. LAP CORNER BARS 40 BAR DIAMETERS OR 2'-0" MINIMUM. LAP ADJACENT MATS OF WELDED WIRE FABRIC 1 1/2 MESH SIDES & ENDS. REINFORCING STEEL TO BE WELDED SHALL BE ASTM A706. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 2.5. CONCRETE PROTECTION: COVER FOR REINFORCING SHALL BE AS FOLLOWS: FOOTINGS & OTHER UNFORMED SURFACES (EARTH FACE): 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER: #6 BARS & LARGER: 2" #5 BARS & SMALLER: 1-1 /2" WALLS, INT FACE, THE LARGER OF ONE BAR DIAMETER OR A MIN OF: 3/4" 2.6. DRILL -IN EXPANSION BOLTS: KWIK BOLT III BY HILTI FASTENING SYSTEMS, "RED HEAD WEDGE ANCHOR" BY ITT PHILLIPS OR APPROVED EQUAL. ICC CERTIFICATION REQUIRED. SPECIAL INSPECTION REQUIRED. 2.7. DRILL -IN ADHESIVE INSTALLATIONS: HILTI HY20 ADHESIVE ANCHOR SYSTEM FOR UNREINFORCED MASONRY OR BRICK WITH CAVITIES, HIT RE 500 SD ADHESIVE ANCHOR SYSTEM BY HILTI FASTENING SYSTEMS OR "SET-3G" EPDXY ANCHOR SYSTEM BY SIMPSON STRONG TIE ANCHOR SYSTEMS FOR SOLID MASONRY OR CONCRETE, OR APPROVED EQUAL. ICC CERTIFICATION REQUIRED. SPECIAL INSPECTION REQUIRED. GENERAL STRUCTURAL NOTES NO SCALE 3. WOOD STRUCTURAL FRAMING: 3.1. WOOD FRAMING: LUMBER SHALL BE KILN DRIED OF MC-15, & GRADED & MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 16, LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS (2X MEMBERS): DOUGLAS-FIR #2 BEAMS & STRINGERS: DOUGLAS-FIR #1 POSTS & TIMBERS: DOUGLAS-FIR #1 STUDS, PLATES, & MISC DOUGLAS-FIR LIGHT FRAMING: STANDARD GRADE TOP & BOT PLATES DOUGLAS-FIR AT BEARING WALLS: CONSTRUCTION GRADE BOLTED STUDS, DOUGLAS-FIR LEDGERS, & PLATES: STANDARD GRADE 2X6 STUDS & PLATES: DOUGLAS-FIR #3/ STUD GRADE 3.2. PLYWOOD SHEATHING: PLY SHEATHING SHALL BE GRADE C-D, UNLESS NOTED OTHERWISE IN THE SPECIFICATIONS. EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE SHALL BE IN CONFORMANCE WITH I.B.C. STANDARDS. SEE PLANS FOR THICKNESS, PANEL IDENTIFICATION & NAILING REQUIREMENTS. 3.3. WOOD PLATES & BLOCKING: ALL WOOD PLATES & BLOCKING IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WITH AWPA APPROVED PRESERVATIVE. PROVIDE TWO LAYERS OF ASPHALT IMPREGNATED PAPER BETWEEN UNTREATED LEDGERS, BLOCKING, ETC., & CONCRETE OR MASONRY. 3.4. TIMBER CONNECTORS: TIMBER CONNECTORS CALLED OUT BY LETTERS & NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG C-2021. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER & SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTIONS SHALL BE INSTALLED IN ACCORDANCE WITH THE MFR'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS & NUTS OF ALL BOLTS & LAG SCREWS BEARING ON WOOD. UNLESS NOTED OTHERWISE ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEASONED & DRIED & THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. ALL JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES JOIST HANGERS. ALL DOUBLE -JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS. ALL TRIPLE -JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS. 4. GENERAL PROJECT INFORMATION: 4.1. SITE VERIFICATION: THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS & CONDITIONS ON SITE PRIOR TO CONSTRUCTION. THE STRUCTURAL ENGINEER HAS NO KNOWLEDGE OF, & IS NOT RESPONSIBLE FOR, THE SITE & SOIL CONDITIONS. 4.2. UTILITIES: CONTRACTOR SHALL VERIFY LOCATIONS OF ALL SITE UTILITIES PRIOR TO EXCAVATION. 4.3. SHORING: CONTRACTOR SHALL PROVIDE TEMPORARY BRACING & SHORING FOR THE STRUCTURE & STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE W/ THE PLANS. 4.4. MEANS & METHODS: CONTRACTOR SHALL BE RESPONSIBLE FOR ALL THE REQUIRED SAFETY PRECAUTIONS & THE METHODS, TECHNIQUES, SEQUENCES & PROCEDURES REQUIRED TO PERFORM THE WORK. 4.5. CHANGES: CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT & STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 4.6. DRAWINGS: "DRAWINGS" INDICATE GENERAL & TYPICAL DETAILS OF CONSTRUCTION, WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW & APPROVAL BY THE STRUCTURAL ENGINEER. 4.7. STRUCTURAL DRAWINGS: THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE ARCHITECTURAL DRAWINGS FOR BIDDING & CONSTRUCTION. CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS FOR COMPATIBILITY & SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4.8. OTHER DRAWINGS: REFER TO ARCHITECTURAL DRAWINGS FOR WALL OPENINGS, ARCHITECTURAL TREATMENT & DIMENSIONS NOT SHOWN. REFER TO MECHANICAL & ELECTRICAL DRAWINGS FOR SIZE & LOCATION OF DUCT OPENINGS, PIPING, CONDUITS, ETC. NOT SHOWN. VERIFY ALL DIMENSIONS & CONDITIONS AT THE PROJECT SITE PRIOR TO STARTING WORK & NOTIFY THE STRUCTURAL ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. REFER TO THE SPECIFICATIONS FOR INFORMATION NOT CONTAINED IN THESE GENERAL NOTES. 4.9. FIELD ERECTED FABRICATIONS: ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE & ERECTION IN ACCORDANCE WITH THE INSTRUCTIONS PREPARED BY THE SUPPLIER. 5. TESTS & INSPECTIONS: 5.1. SPECIAL INSPECTIONS: SPECIAL INSPECTIONS SHALL BE PERFORMED IN ACCORDANCE WITH I.B.C. CHAPTER 17 BY A TESTING AGENCY APPROVED BY THE AUTHORITY HAVING JURISDICTION FOR THE FOLLOWING COMPONENTS: L GUARD RAILING INSTALLATION. 5.1. INSPECTION REPORTS: SUBMIT SPECIAL INSPECTION REPORTS TO THE CITY OF EDMONDS BUILDING DEPARTMENT, THE GENERAL CONTRACTOR, PROPERTY OWNER, ARCHITECT, & THE STRUCTURAL ENGINEER OF RECORD. - END OF GENERAL STRUCTURAL NOTES - AM E NTOG RO U P 710 2nd Avenue, Suite 400 Seattle, WA 98104 amentogroup.com O f 3 AL' NAL��G� 03/09/2023 ENGINEER'S SEAL APPLIES TO STRUCTURAL DESIGN ONLY The documents created by Amento Group and its Consultants for this project are instruments of Amento Group's service. Amento Group retains all common law, statutory and other reserved rights, including the copyright. Amento Group's documents shall not be used by anyone on any other project, except with Amento Group's written permission. TU RESIDENCE 7219 164th PL SW EDMONDS, WA 98026 DECK REPLACEMENT DESIGN APPROVED STRUCTURAL DETAILS PERMIT PLANS MUST E DOCUMENTS PROJECT#: ON JO SITE 200291 DRAWN BY: WFL CHECKED BY: DSJ = The following documentation shall be available on REVISIONS: site for the building inspector: • F-] COE APPROVED ARCHITECTURAL PLAN SET ' ■ BLDG DEPT: COE APPROVED STRUCTURAL PLAN SET ' [:]COE REVIEWED CALCULATION PACKET RECEIVED - ❑ ENERGY CREDIT WORKSHEET Mar 16 2023 ■ CITY OF EDMONDS DEVELOPMENT SERVICES ■ 0SITE PLAN DEPARTMENT ❑ CIVIL PLAN ■ ; DATE: . � 03-09-23 ■ SHEET TITLE: ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 GENERAL STRUCTURAL NOTES SHEET #: BLD2023-0325 S001 LEGEND: (E) J1 (E) JOISTS, SIZE VERIFY IN FIELD (E) R1 (E) (5) - 2X10 RIM JOISTS, SIZE VERIFY IN FIELD; IF NOT PRESENT, STRENGTHEN AS DIRECTED BY STRUCTURAL ENGINEER OR REPLACE W/ 2.0E 3-1/2 X 11-1/4 PSL BEAM J2 P.T. 2X8 HF #2 JOISTS @ 16" O.C. R2 (2) - 2X8 HF #2 RIM JOISTS / JOISTS L1 P.T. 2X8 HF #2 LEDGER B1 P.T. 4X10 HF #2 BEAM B2 P.T. 4X8 HF #2 BEAM S1 (2) - P.T. 2X12 HF #2 NOTCHED STAIR STRINGER @ 12" O.C. UPPER FLOOR DECK FRAMING PLAN 1 /4" = 1'-0" LEGEND: P1 S1 deckplan P.T. 4X4 HF#2 POST (2) - P.T. 2X12 HF #2 NOTCHED STAIR STRINGER @ 12" O.C. LOWER FLOOR & FOUNDATION PLAN 1 /4" = 1'-0" deck_plan_002 (E) BUILDING EXTERIOR WALL, TYP ALIGN RAILING AND WINDOW DIVIDER POST STAIRWAY WITH HANDRAIL F*WTINTAMUOM 2 4 S2.0 S2.0 TYP TYP (E) R1 DOWN r \ J2 . \ I NOT IN SCOPE OF WORK SIMPSON DTT1Z TENSION TIES, TYP (TOTAL OF (8) - PLACES) 3'-0" 7 1�1- ' J2 ti 1 _BEAM CANT. 7 S2.0 TYP \—BEAM HANGER, TYP ----o\-P.T. 2X4 FLAT V-BRACE— AT BOTTOM, TYP BEAM CANT. � ' R2 �k---POST BELOW, TYP 1'- 0' DECKING BOARD PER DOUBLE JOIST W/ JOIST OWNER, TYP HANGER, CONT 15'-0" EDGE OF DECK, TYP JOIST CANTILEVERED, TYP (E) BUILDING EXTERIOR WALL, TYP (E) WOOD FRAMED PLATFORM STAIRWAY STAIRS: (15) - RISERS @ 7-1/2" RISE +/- & (14) -TREADS @ 11" RUN ADD POST & FOOTING, TYP REUSE (E) CONC FOOTING &— (E) POST BASE FOR POST, TYP 6'-7" 6'-711 (E) STEP 4 S2.0 TYP J J2 (E) CONIC PLINTH & (E) FOOTING 7 S2.0 TYP EQ ADD POST & FOOTING, TYP 0 EO BEAM CANT. DECKING BOARD PER OWNER, TYP ALUMINUM GUARDRAILING ALL EXTERIOR DECK FLOOR PERIMETER EDGES, PER OWNER N AM E NTOG RO U P 710 2nd Avenue, Suite 400 Seattle, WA 98104 amentogroup.com ENGINEER'S SEAL APPLIES TO STRUCTURAL DESIGN ONLY The documents created by Amento Group and its Consultants for this project are instruments of Amento Group's service. Amento Group retains all common law, statutory and other reserved rights, including the copyright. Amento Group's documents shall not be used by anyone on any other project, except with Amento Group's written permission. TU RESIDENCE 7219 160 PL SW EDMONDS, WA 98026 DECK REPLACEMENT DESIGN STRUCTURAL DETAILS PERMIT DOCUMENTS PROJECT #: 200291 DRAWN BY: WFL CHECKED BY: DSJ REVISIONS BLDG DEPT: RECEIVED Mar 16 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT DATE: 03-09-23 SHEET TITLE: DECK FRAMING & FOUNDATION PLAN SHEET #: S100 EMPLOY CS 16 AT SIMPSON CS 16, Flashing shall be GUARDRAIL WRAPAROUND SEE DETAIL 2/S2.0 FOR LEDGER & JOISTS (E) WALL FRAMING AM E NTOG RO U P ATTACHMENT RIM JOIST installed to prevent SIMPSON LU (E) WALL FRAMING ONLY CONNECTION 710 2nd Avenue, Suite 400 JOIST HANGER Water intrusion DECKING BOARD 11" TYP (E) FLOOR SHEATHING Seattle, WA 98104 GUARDRAIL I I DECK BOARD DECK BOARD (E) FLOOR SHEATHING ATTACHMENT 0 (1) - SIMPSON H2.5A PER PLAN amentogroup.Com PER MFR 1 CLIP AT EACH FACE I Fil OF JOIST SIMPSON LU 1 JOIST HANGER ' COTT ✓O,t, ``Ns RIM JOIST WAS F Hj PER PLAN P.T. 2X SOLID BLKG Iwo 4 (E) DOUBLE RIM, JOIST PER PLAN, P.T. 2X4 V-BRACE BOT JOIST PER PLAN �. E DOUBLE RIM, (E) � JOIST PER PLAN SIZE VERIFY IN FIELD CANTILEVERED �� W/ (2) - #10 X 3 S.S. SIMPSON DTT1Z TENSION SIZE VERIFY IN FIELD 3 w� ; v w �AL� (1) - 5/8" DIA. X 5" LONG LEDGER PER PLAN SIMPSON AC4 WOOD SCREWS TO EACH JOIST TIE W/ (1) - 3/8" DIA. S.S. X L SECTION MIN 3" THREAD ��s S.S. LAG SCREWS W/ (2)-16 D NAILS @ 16" O.C. P.T. 2X4 V-BRACE BOT POST CAP SECTION BEAM PER PLAN REQ'D LAG SCREWS & (8) - 0.148" X 1-1/2" NAILS PENETRATION 03 2023 TO LEDGER W/ (2) - #10 X 3" S.S. POST PER PLAN TO JOIST LEDGER PER PLAN ENGINEER'S SEAL APPLIES TO O STRUCTURAL DESIGN ONLY SECTION WOOD SCREWS NOTE: JOIST AND BEAM TO POST CONNECTION APPLIES AT DETAIL SIMILAR. NOTE: SEE PLAN FOR DTT1Z LOCATIONS. TO EACH JOIST The documents created by 1 NOT USED 2 TYP LEDGER TO JOISTS AT (E) EXT WALL 3 TYP BEAM TO POST AT JOIST CANT. 4 TYP TENSION TIE TO JOISTS Amento Group and its Consultants for this project are S2.0 S2.0 1" = 1'-0" WD_LDG_JST_001 S2.0 1" = 1'-0" WD_BM-PST _001 WD_JST_TIE_001 S2.0 1" = 1'-0" instruments of Amento Croup's service. Amento Group retains all LEDGER PER DETAIL 2/S2.0 common law, statutory and other E JOISTS, CANTILEVERED, ( ) FASTENER PER DECKING BOARD TYP ADD (1) - SOLID BLKG FOR DOUBLE BLKG; DECKING BOARD reserved rights, including the copyright. Amento Group's TYP DECKING MFR SIMPSON CS 16 VERIFY IN FIELD RIM JOIST documents shall not be used by WRAPAROUND— STAIR TREADS, TYP 3" +/- PER PLAN anyone on an other project, Y Y p J BEAM except with Amento Group's DECKING BOARD ICI SIMPSON LCE4 written permission. -__ - POST CAP BEAM PER ---,I PLAN 11" TYP 77-1 STAIR STRINGER GUARDRAIL PER PLAN T TU RESIDENCE (E) WALL FRAMING/ SIMPSON LTP4 CLIP, ATTACHMENT (E) FLOOR FRAMING SHAPED BEARING ----__BEAM PER PLAN EACH END PER MFR SEAT FOR STAIR r 77�- SIMPSON P.T. 2X4 V-BRACE BOT STRINGER, TYP POST PER PLAN (2) -ROWS 16° NAILS LPC4Z SECTION W/ (2) - #10 X 3" S.S. 7219 1641h PL SW @ 16" O.C. POST CAP WOOD SCREWS SIMPSON HUC48 EDMONDS, WA 98026 JOIST PER PLAN POST PER TO EACH JOIST BEAM HANGER DOUBLE JOISTS SECTION PLAN JOIST PER PLAN BEAM PER PLAN AT STEP SECTION NOTE: EMPLOY SIMPSON CS 16 AT GUARDRAIL ATTACHMENT ONLY. DECK 5 NOT USED 6 TYP STEP AT (E) DECK 7 TYP WOOD BLOCKING REPAIR AT (E) JOISTS 8 HIGH BEAM TO LOW BEAM AT POST 52.0 1-1/2" = V-0" WD_STEP_DECK_001 52.0 1 " = 1'-0° WD_BLKG_RPAR_001 S2 0 1 " = 1'-0° WD_BM_BM_001 REPLACEMENT S2.0 DESIGN 1'-6" POST, CONC PLINTH & RIM JOIST PER PLAN T a T FOOTING 1-1/2" CLR � 1-1 /2 EACH WAY CLR STAIR STRINGER _ SIMPSON CB44 I PER PLAN t I 11 B t POST BASE W/ a(2) - 5/8" DIA. S.S. POST S26B .0 STRUCTURAL DETAILS S2.0 I a THRU BOLTS PLAN .-. a CONC PLINTH w FINISH GRADE 8" DIA. = #3 XOTIES, 0 SIMPSON LTP4 CLIP, -- JOINT STRINGER & 5-1/2" MIN PERMIT Q BEAM - DOCUMENTS & REINF. CONC FOOTING (3) - @ 2" O.C. III -III -III- 11 AT TOP, 'i-IIII�III=' II L ----------- SHAPED BEARING SEAT FOR STAIR �IIIII; (4) - #4 X PROJECT# PER PLAN BALANCE Z VERT, HOOK _ STRINGER, TYP A PLAN @ 4" O.C. a a ENDS IN _---------- 20029 - FOOTING BEAM PER PLAN DRAWN BY: oa T ; WFL III i = #4 EACH � SIMPSON AC4 CHECKED BY: DSJ fill' POST CAP REVISIONS: STANDARD 'CV U WAY AT BOT HOOK, TYP SECTION POUR FOOTING B ON UNYIELDING POST PER PLAN 9 NOT USED 10 NOT USED 11 TYP POST TO CONC FOOTING SOIL S2.0 1" = 1'-0" WD_CONC_FTG_001 A ELEVATION S2.0 S2.0 BLDG DEPTSTA: STRINGER PER PLAN JOIST PER PLAN RECEIVED (E) DECKING BOARD Mar 16 2023 NOTCH STRINGER CITY OF EDMONDS DEVELOPMENT SERVICES 5-1/2" MIN TO FIT TRUST BLK I DEPARTMENT \ �Xl (E) JOIST, SIZE - -_ _ P.T. 2X4 TRUST BLK VERIFY IN FIELD I I DATE 03-09-23 SHEET TITLE 1 (E) FINISHED GRADE STRUCTURAL DETAILS SIMPSON HUTF P.T. 4X SOLID BLKG 1/2" DIA. X 6" LONG HANGER, TYP; SECTION S.S. LAG SCREWS SIMPSON LU HANGER @ 9" O.C. IN PRE- DECKING BOARD, TYP AT EACH END BORED HOLES SHEET # (TOTAL OF (4) - SCREWS) PLAN g 13 NOT USED 14 NOT USED 15 TYP STAIR 52.0 1" = 1'-0" STRINGER TO (E) PLATEFORM WD_STGR_BOT _001 16 TYP STAIR STRINGER TO LOW 52.0 1" = 1'-0" BEAM WD_STGR_PST_001 S2 0 0 S2.0 52.0