APPROVED FIR2022-0028+Fire_Alarm_Equipment_Specification_Sheets+3.16.2022_10.33.50_AM+2740853
RECEIVED FIR2022-0028 3/16/22 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT , Fire Systems West, Inc. S 206 FRONTAGE ROAD NORTH, SUITE C PACIFIC, WA 98047 (253) 833-1248 J I :i :9_101_1:i u Equipment Submittal FOR Main St. Commons (East Building) 550 Main Street Edmonds, WA 98020 Honeywell FarenhytT" Seri THE POWER OF CONNECTED I FP-300 / I FP-300 Intelligent Fire Alarm Cont The IFP-300 (red) and IFP-300B (black) arrintelligent analog/addressable fire alarm control panels (FACP). The basic IFP-300 panel contains one built in signaling line circuit (SLC), which can support 159 (IDP/SK) System Sensor' sensors and 159 IDP/SK modules or 127 (SD) Hochiki° devices per ar loop. Additional SLC loops can be added using the model 6815 SLC o ❑ expander for SK/IDP devices to increase the overall point capacity to a maximum of 300 points per panel, or mod 15XL for SD devices to increase the overall point capacity to a ma m of 254 points per panel. IFP-300 has the interconnection capabilityfor up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. To network panels together use the SK-NIC network interface card. Copper wire or fiber optic cable panel connectivity can be used within the same networked system. IFP-300 has a built-in dual phone line, digital alarm communicator/ transmitter (DACT), IP or optional cellular technologies, Form C trouble relay, and two programmable Form C relay&P-300 has powerful features such as detector sensitivity, day/night thresholds, drift compensation, IFP-300B pre -trouble maintenance alert, and calibration trouble alert. The IFP-300 supports a variety of devices, including RA-2000, RA-1000 or RA-100 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), RPS-1000 power module, and IDP, SK or SD devices. FEATURES & BENEFITS • Network support for up to 32 Sites • Built-in support for up to 1591DP/SK detectors and 159 IDP/SK modules or 127 SD SLC devices • Four line LCD display with 40 characters per line • Available in a red or black cabinet • IFP-300 can be surface or flush mounted • Built-in USB interface for convenient and quick programming • Firmware can be upgraded in the field • Network card allows copper network connection with a multi -mode or single -mode fiber connection option • Built-in dual phone Line, digital alarm communicator/ transmitter (DACT), I or optional cellular technologies • JumpStart AutoProgramming' feature for easy programming • Supports up to four SWIFTwireless gateways. Each gateway can have up to 49 wireless devices • Supports Class B (Style 4) and Class A (Style 6 or Style 7 configuration for SLC, and SBUS. • Built in synchronization for appliances from AMSECO, Gentex°, System Sensor', and Wheelock IFP-300 Technical Specifications PHYSICAL: Overall Dimensions: 26.4"H x 16.4"W x 4.11"D Weight: 45 lbs. Color: Red or Black ENVIRONMENTAL Operating Temperature: 32°Fto120°F (01Cto 49°C) Humidity: 0 to 93% relative humidity (non - condensing) ELECTRICAL: IFP-300 Primary AC: 120VAC @ 60 Hz, 3.3ATotal Accessory Load: 6A @ 24VDC power -limited Standby Current:190mA Alarm Current: 250mA Battery Charging Capacity: 17 to 55AH Battery Size: 18AH max. allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. AGENCY LISTINGS AND APPROVALS N FPA 13, N F PA 15, N F PA 16, N F PA 70, & N F PA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service UL Listed CSFM: 7165-0559:0504 FDNY:COA#6245 Seismic (CA) (pending) FM approved APPROVED RELEASING SOLENOIDS Asco T821OA107 24 VDC 3 A max 0 Hz Asco 821OG207 24 VDC 3 A max 0 Hz COMPATIBLE DEVICES See the data sheets listed below for a complete Listing of the IDP, SK, SWIFT or SD devices. 350361: IDP Device Protocol data sheet 53623: SK Device Protocol data sheet 350360: SD Device Protocol data sheet 350615 & 350617: SWIFT devices data sheet For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Farenhyt 12 Clintonville Road Northford, CT 06472 800-328-0103 ORDERING INFORMATION IFP-300: Intelligent Fire Alarm Control Panel. Red Cabniet. IFP-30OB: Intelligent Fire Alarm Control Panel Black Cabinet. SBUS ACCESSORIES RA-2000, RA-1000, RA-1000R, RA-100, RA-2000GRAY: Remote annunciators 6815: Signal Line Circuit (SLC) Expander for IDP or SK devices 5815XL: Signal Line Circuit(SLC) Expanderfor SD devices RPS-1000: Power Supply 5496: NAC Expander 5824: Serial/Parallel Module 5880: LED I/O Module 5865-3 or 5865-4: LED Annunciator 5883: Relay Interface MISCELLANEOUS ACCESSORIES HFSS: Software Suite. Provides programming, upload/download and event reporting RBB: Remote Battery Box Cabinet. Use for backup batteries up to 35 AH. Dimensions:16" W x 10" H x 6" D SK-SCK: Seismic Compliance Kit SK-NIC: Network Interface Card SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode CELL -MOD: Cellular Communicator in Plastic Enclosure CELL-CAB-SK: Cellular Communicator in Metal Enclosure with lock and key 3516031AI11/17 © 2017 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. SWIFT° and Honeywell' are registered trademarks of and Farenhyt- is a trademark of Honeywell International, Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, Please call 800-446-6444. Honeywell SILENT Farenhyt KNIGHT by Honeywell AnnunciatorRemote Remote Annunciator Agency Listings T'" M EA RA-1000 N (US F nn �R VY APPROVED 429-92-E Vol IX The RA-1000 is a remote annunciator used to operate and program IFP-series fire alarm control panels (FACPs). The RA- 1000's keypad and display match the built-in annunciator of the IFP-1000 control panel. The remote annunciator connects to the control panel via the RS-485 system bus. When the system is in normal operation and has AC power, the Power LED is lit and all other LEDs are off. The other LEDs turn on Qb Eb 0 41 Cirs%1 as alarms, supervisories, troubles, system silenced and AC power losses occur. Features • 80-character backlit LCD display (4 lines with 20 characters on each line) RA-1000 • Tactile and audible feedback • Accepts user codes or fire fighter's key Installation • Larger keypad buttons for system reset and silence The RA-1000 can be surface or flush • RS-485 interface to panel mounted. Use the optional trim ring for surface • Operation and appearance is identical to IFP-1000 built-in mounts. When flush mounting an electrical annunciator box is optional. If using an electrical box, use • Install up to eight RA-1000s per FACP a 4S, single -gang, or double -gang box. • Support for simultaneous use of multiple RA-1000s Compatibility • On -board piezo sounder audibly indicates alarms, troubles, The RA-1000 is compatible with the following and supervisories FACPs: • Five status LEDs for alarm, supervisory, trouble, silence and . IFP-1000ECS Emergency Communication AC power conditions System with Fire Alarm Control Panel • Available in red or light gray • IFP-100ECS Emergency Communication • Wiring lengths up to 6000 ft. from the FACP (depending on System and Fire Alarm Control Panel wire gauge and number of devices on SBUS) • IFP-1000 Intelligent Fire Panel • UL listed, complies with NFPA 72 • IFP-100 Intelligent Fire Panel • CSFM approved • IFP-50 Intelligent Fire Panel • M EA P/N 350071 Rev D Copyright © 2012 Honeywell International Inc. FlexputT" is a Trademark of Silent Knight Jumpstart® is a Registered Trademark of Silent Knight IFP-1000 FACP RA-1000 RA-1000 0, u al'�• P • Up to 8 RA-1000 per system • 80-character backlit LCD display (4 lines with 20 characters each) • Wiring lengths up to 5000 ft. from the control panel Specifications Physical Height: 7.4" (18.8 cm) Width: 9.1" (23.1 cm) Depth: 1.5" (3.8 cm) Shipping Weight: 2.8 Ibs (1.3 kg) Color RA-1000R: Red RA-1000: Gray Electrical Operating Voltage: 24 VDC Standby Current: 20 mA max Alarm Current: 25 mA Wiring Distance: 6,000 max. from FACP (depending on wire gauge and number of devices on the SBUS) Max Per System: 8 Environmental Operating Temperature: 320F — 120OF (0°C — 49°C) Humidity: 10% — 93% non -condensing RA-1000 vu� qUo Q . oua Approvals • NFPA 72 • UL Listed; • CSFM 7170-0559: 135; • MEA 429-92-E Vol. IX; • FM Approved Ordering Information RA-1000R Remote Annunciator. Four line LCD annunciator with 20 characters per line. Red. RA-1000 Remote Annunciator. Four line LCD annunciator with 20 characters per line. Gray. Accessories 5860TR Red Trim Ring. For surface mounting. 5860TG Gray Trim Ring. For surface mounting. SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 by Honeywell Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Made in the U.S.A. Honeywell FarenhytT" Seri THE POWER OF CONNECTED Farenhyt IDP-PHO 0-W Series Intelligent Plug-in Photoel Detectors Honeywell's IDP-PHOTO-W Series intelligent plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The IDP-PHOTO-W Series detector sensitiv can be programmed in the control panel software. Sensitivity is contin sly monitored and reported to the panel. Point ID capability allows eac tector's address to be set with rotary, decimal address switches, prove g exact detector location for selective maintenance when chamber cont ination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the IDP-PHOTO-T. The IDP-PHOTO-R is a remote test capable detector for use with DNR Series duct detector housings FEATURES & BENEFITS • New modern profile • Optional remote, • Built-in tamper - for improved single- gang LED resistant feature aesthetics accessory . Sealed against back • Stable communication • Dual LED design pressure technique with noise provides 360'viewing . Expanded color immunity angle options • Low standby current • Remote test feature • SEMS screws for • Two -wire SLC from the panel wiring of the separate connection • Built-in functional test base switch activated by external magnet IDP-PHOTO-W in B300-6 base • Optional relay, isolator, and sounder bases • Plugs into separate base for ease of installation and maintenance DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications referto NFPA 72. System Smoke Detector Application Guide, documentA05-1003, is available at systemsensor.com INSTALLATION The IDP-PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: • Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class °B") wiring. • When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION NOTE: Detectors must be mounted to one of the Intelligent Bases listed below IDP-PHOTO-W: White, low -profile intelligent photoelectric sensor. IDP-PHOTO-IV: Ivory, low -profile intelligent photoelectric sensor. IDP-PHOTO-T-W: White, same as the IDP-PHOTO-W, but includes a built-in 135°F (57°C) fixed -temperature thermal device. IDP-PHOTO-T-IV: Same as IDP- PHOTO-T but in Ivory. IDP-PHOTO-R-W: White, low -profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW.. IDP-PHOTO-R-IV: Ivory, low -profile intelligent photoelectric sensor, remote test capable. For use with DNR/DNRW. INTELLIGENT BASES B300-6: White, standard flanged low -profile mounting base. B300-6-BP: Bulk pack of B300-6, package contains 10. B300-6-IV: Ivory, standard flanged low -profile mounting base. B501-WHITE: White, standard European flangeless mounting base. UL listed. B501-BL: Black, standard European flangeless mounting base. UL listed. B501-IV: Ivory, standard European flangeless mounting base. UL listed. B20OS-WH: White, Intelligent, programmable sounder base. B20OS-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base for retrofit applications. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224BI-WH: White, plug-in System Sensor isolator detector base. B224BI-IV: Ivory, plug-in System Sensor isolator detector base. ACCESSORIES TR300: White, replacement flange for B21OLP and B300-6 bases. TR300-IV: Ivory, replacement flange for B21OLP and B300-6 bases. RA10OZ: Remote LED annunciator. 3 — 32 VDC. Mounts to a U.S. single -gang electrical box. For use with B501 and B300(A)-6 bases only. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. CK300: White, detector color kit. Pack of 10. CK300-IV: Ivory, detector color kit. Pack of 10. CK300-BL: Black, detector color kit. Pack of 10. Farenhyt IDP-PHOTO-W Series Technical Specifications PHYSICAL Height: 2.0" (51mm) installed in B300-6 base Diameter: 6.2" (156mm) installed in B300-6 base 4.1" (104 mm) installed in B501 base Weight: 3.4 oz (95 g) ENVIRONMENTAL Operating Temperature range: Photo: 32°F to 122°F (0°C to 50°C) Photo with Thermal: 320F to 100OF (0°C to 38°C) Thermal Ratings: Fixed Temperature Set point: 1350F(570C) Sensitivity: U L Applications: 0.50/6 to 4.00/o per foot obscu ration. ELECTRICAL RATINGS Voltage Range:15 to 32VDC peak Operating Current C 24VDC: 200µA (one communication every 5 seconds with green LED blink on communication) Maximum Current: 4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell's Farenhyt Series and other products available by visiting www.farenhyt.com Honeywell Farenhyt 12 Clintonville Road Northford, CT 06472 800-328-0103 COMPATIBILITY The IDP-PHOTO-W series detectors are compatible with the following Farenhyt Series FACPs: • IFP-2100 / IFP-2100ECS / RFP-2100 • IFP-2000 / IFP-2000ECS / RPS-2000 • IFP-1000/ IFP-1000ECS • IFP-300/ IFP-300ECS • IFP-100/IFP-100ECS • IFP-75 • IFP-50 AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S6173 FM approved CSFM: 7272-0559:0512 Doc 351629 1 Rev Al 04/18 © 2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.farenhyt.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Honeywell'and System Sensor' are registered trademark of and Farenhyt" is a trademark of Honeywell International, Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, Please call 800-446-6444. Honeywell Farenhyt IDP-Heat, IDP-Heat-HT, & IDP-Heat-ROR The IDP-Heat, IDP-Heat-HT, and IDP-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors. These thermal detectors are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Heat is a fixed temperature thermal detector that uses a thermistor sensing circuit to produce 1350F (57°C) fixed thermal detection. IDP-Heat-HT is a variable high temperature detector that provides high temperature detection at 135°F — 190°F (57°C — 880C). IDP-Heat-ROR is a fixed temperature and rate -of -rise thermal detector that uses a thermistor sensing circuit to produce 1350F (57°C) thermal protection. Features • Sleek, low -profile design • Reliable analog communications for trouble -free operation • Age resistant polymer housing • Innovative thermistor sensing circuit • Superior EMI resistance for reliability • Variety of mounting options to meet any application • Dual LED indicators for 3601 visibility • Detector transmits signal to indicate maintenance is required • Plug-in mounting provides ease of installation • Optional remote LED annunciator (PN SSRA400Z; System Sensor® PN RA400Z) • Tamper -proof feature available on mounting bases • Rotary address switches for fast installation • UL Listed Installation The IDP thermal detectors plug into a compatible IDP-series detector base. SILENT 7550 Meridian Circle, Suite 100 Maple Grove, Mn 55369-4927 U. KNIGHT 763-493-6455 or 800-328-0103 Fax: 763-493-6475 www.farenhyt.com Icy Honeywell Addressable Thermal and Rate -of -Rise Thermal Detectors M EA 383-02-E Vol. VI IDP-Heat Installed in the IDP-6AB Mounting Base (Base Not Included) Compatibility The IDP-Heat, IDP-Heat-HT, and IDP-Heat-ROR are compatible with the following IDP-series detector bases: • IDP-6AB 6" Mounting Base • SSB501 4" Mounting Base* • SSB224BI 6" Isolator Base* • SSB224RB 6" Relay Base* • SSB501 BHT-2 6" Temporal Sounder Base* The IDP-Heat, IDP-Heat-HT, and IDP-Heat-ROR are compatible with the following FACPs: • IFP-2000/RPS-2000 Intelligent Fire Panel • IFP-1000 Intelligent Fire Panel • IFP-100 Intelligent Fire Panel • IFP-50 Intelligent Fire Panel " For ordering purposes, an SS has been added to the System Sensor part numbers. Example —System Sensor PN for SSB501 is B501. P/N 350285 Rev D Copyright © 2008 Honeywell International Inc. i,...,..___..,.,.,..__..,.,.,.,_....,.,,ClessAdpllane144Gring ..............._,,,,,,,.,.,.,.,,,............ ...,.,.....,__..,.,.,..___..,.,.,....__,.....,.,...,.._...F W61ng OF-Serlea Dwilimtor Mounting Bases Specifications* Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) Shipping Weight: 4.8 oz (136 g) Electrical Operating Voltage: 15 — 32 VDC Standby Current IDP-Heat: 200 CIA @ 24 VDC (no communication; LED off) 300 CIA @ 24 VDC (one communication every 5 sec with LED enabled) IDP-Heat-HT & IDP-Heat-ROR: 150 pA @ 24 VDC (no communication; LED off) 200 pA @ 24 VDC (one communication every 5 sec with LED enabled) Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature IDP-Heat & IDP-Heat-ROR: -40 — 100°F (20°C — 38°C) IDP-Heat-HT: -41— 150°F (20°C — 66°C) Humidity: 10% — 93% non -condensing Thermal Ratings IDP-Heat: Fixed temperature setpoint 135°F (57°C) IDP-Heat-HT: High temperature heat 135°F — 190°F (57°C — 88°C) IDP-Heat-ROR: Rate -of -rise detection 151F/min (91C/min) Ordering Information IDP-Heat Fixed Temperature Thermal Detector IDP-Heat-HT Fixed High Temperature Thermal Detector IDP-Heat-ROR Fixed Temperature and Rate -of -Rise Thermal Detector Accessoriesf SSRA40OZ Remote LED Annunciator. SSRMK400 Recessed Mounting Kit. Provides low profile for use with B501. SSXR2B Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the T55-127-000. SSM02-04-00 Replacement Test Magnet. SSM02-09-00 Test Magnet with Telescoping Handle. SSXP-4 Extension Pole for XR2B. Extends from 5 — 15 ft. SST55-127-000 Detector Removal Head. SSBCK-200B Black Detector Kit. For IDP-series detectors. Unless otherwise noted, specifications apply to all IDP thermal detectors. t For ordering purposes, an SS has been added to the System Sensor part numbers. Example —System Sensor PN for SSB501 is B501. ILE1T This document is not intended to be used for installation purposes. We try to keep our 3. KNIGHT product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple by Honeywell �y Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Made in the U.S.A. 4,�� SYSTEM 5600 Series Mechanical Heat Detectors System Sensor' 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non -life -safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: — Single- and dual -circuit models — Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. • Plain housing for residential installations (Model 5601P) • Easy -to -use terminal screws • A broad range of back box mounting options: — Single gang — 3.5"and 4"Octagonal — 4"square with square to round plaster ring • Reversible mounting bracket Agency Listings 0i @ UDC AR S2101 3016008 CSG30 7270-1653:0167 FM LISTED APPROVED Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual -circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four -square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface -mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate -of -rise units are marked FX/ROR. The 5600 series also provides a post -activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series model number , listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single -circuit or a dual -circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90oC), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Maximum Installation Temperature 5601 P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150OF (65.6°C) Operating Humidity Range 5 to 95% RH non -condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194OF (90°C) Weight 6 oz. (170 grams) Rate -of -Rise Threshold 150F (8.3°C) rise per minute (models 5601 P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact 6-125VAC / 3A Ratings 6-28VDC / 1 A 125VDC / 0.3A 250VDC / 0.1A Input Terminals 14-22 AWG "yd (D 5601 P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information 5601 P Single None 135°F (57°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 1940F (90-C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 1350F (57-C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering `NOTE: Refer to NFPA72 guidelines for 1940F (90-C) Fixed Temperature spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2013System Sensor. Product specifications subject to change without notice. Visit systemsensorcom Phone: 800 SENSOR2 •Fax: 630 377 6495 or current product information, including the latest version of this data sheet. SENSOR" www.systemsensor.com SPDS30001.7/13 Farenhyt Addressable Relay Module IDP-Relay The IDP-Relay is an addressable relay module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Relay allows a Silent Knight FACP to switch discrete contacts by code command. The relay contains two isolated sets of Form C contacts, which operate as a DPDT switch. No supervision is provided for the notification appliance circuit. The IDP-Relay contacts can be used for virtually any normally open or normally closed application. Each IDP-Relay is programmed with a unique signaling line circuit (SLC) loop address. When an event occurs that controls the IDP-Relay, the relay is triggered by the FACP. Features • Two sets of Form C contacts • Contacts are rated for a variety of amps (see Specifications) • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Relay programming is completely flexible —can be mapped to zone conditions • Polling LED visible through the cover plate • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring • UL Listed Relay Contact Ratings Current Rating Max Voltage Load Description Application 3 A 30 VDC Resistive Noncoded 2 A 30 VDC Resistive Coded 0.7 A 70.7 VDC PF = 0.35 Noncoded 0.9 A 125 VAC Resistive Noncoded 0.46 A 30 VDC L/R = 20 ms Noncoded 0.5 A 125 VAC PF = 0.75 Noncoded 0.3 A 125 VAC PF = 0.35 Noncoded 2 A 25 VAC PF= 0.35 Noncoded SILENT KNIGHT by Honeywell Agency Listings MEA V 'O: L 386-02-E Vol II OP -Relay Compatibility The IDP-Relay is compatible with the following FACPs: • IFP-2000 / RPS-2000 Intelligent Fire Panel • IFP-2000ECS Emergency Communication System with Fire Panel • IFP-1000 / ECS Intelligent Fire Panel • IFP-100 / ECS Intelligent Fire Panel • IFP-50 Intelligent Fire Panel • IFP-25 Intelligent Fire Panel Installation The IDP-Relay mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. P/N 350290 Rev J © 2015 Honeywell International Inc. CONNECT MODULES TO LISTED COMPATIBLE (-} CONTROL PANELS ONLY. (-) TO NEXT FROM PANEL OR PREVIOUS DEVICE (+} �� (+) _ DEVICE RELAY CONTROL MODULE 0lop O O o A o T1t Relay Common 2 Tt0 Tt Normally Closed 2 T9 TS Normally Open 2 Ta T; Relay Common 1 T� , 9 TA Normally Closed 1 T6 3 � ; T' 2 106 +U TENS e ONES � C Specifications Physical 4.675" H x 4.275" W x 1.4" D Shipping Weight: 6.3 oz (196 g) Environmental Operating Temperature: 32°F — 120OF (0°C — 49°C) Humidity: 10% — 93% non -condensing Electrical Operating Voltage: 15 — 32 VDC End -of -Line Resistance: Not used SLC Standby & Alarm Current:.2551 max @ 24 VDC (one communication every 5 sec with LED enabled) If any wiring to Terminals 4-10 is Nonpower limited, The CB500 barrier is required. The CB500 includes a Nonpower limited label, which must be placed over the Power Limited terminal information on 1) the name plate label. W Unused Normally Open 1 *NOTE: ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE. Ordering Information IDP-Relay Relay Module Accessories SMB500 4" Square Surface Mount Electrical Box CB500 Module Barrier SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or KNIGHT anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call by Honeywell Assembledin the 800-446-6444. www.farenhyt.com U.S.A. Farenhyt Addressable Monitor Module IDP-Monitor The IDP-Monitor is an addressable monitor module for use with Silent Knight IFP-series fire alarm control panels (FACPs). The IDP-Monitor acts as an interface to contact devices, such as waterflow switches and pull stations. The IDP-Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4-wire smoke detectors can be monitored for alarm and trouble conditions. Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate • Rotary address switches for fast installation • SEMS screws for easy wiring • UL Listed Installation The IDP-Monitor mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. SILENT KNIGHT by Honeywell Agency Listings UO MEA L 386-0-E-Vol2 OP -Monitor Compatibility The IDP-Monitor is compatible with the following FACPs: • IFP-2000 / RPS-2000 Intelligent Fire Panel • IFP-2000ECS Emergency Communication System with Fire Panel • IFP-1000 / ECS Intelligent Fire Panel • IFP-100 / ECS Intelligent Fire Panel • IFP-50 Intelligent Fire Panel P/N 350288 Rev J Copyright © 2015 Honeywell International Inc. TO NEXT DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED. DO NOT MIX MODULE FIRE ALARM INTIATING, SUPERVISORY, OR o 0 SECURITY DEVICES ON THE SAME MODULE. e e n 47K EOL IT M T RESIST o ,.. o do ,-. INITIATING DEVICE CIRCUIT (IDC) - NFPA STYLE B POWER LIMITED: 45DNA MAX, @ 11 VDC MAX FROM PANEL OR PREVIOUS DEVICE CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY ALL WIRING SHOWN IS SUPERVISED AND POWER LI MITED INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS, Typical Wiring for IDP-Monitor Module, NFPA Style B TO NEXT FROM PANEL OR DEVICE �/— — — — �Q * PREVIOUS DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT MODULE CLOSURE DEVICES MAY BE USED. DO NOT MIX CONNECT MODULES TO LISTED COMPATIBLE FIRE ALARM INTIATING, SUPERVISORY, OR �O Q��J CONTROL PANELS ONLY SECURITY DEVICES ON THE SAME MODULE. e n H T EOL RESISTOR IS INTERNALAT \J�.� feewfl ALLWIRING SHOWN IS SUPERVISED AND POWER LIMITED TERMINALS 8 & 9 13 L_J INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. Typical Wiring for IDP-Monitor Module, NFPA Style D Specifications Physical Height: 4.5" (11.4 cm) Width: 4" (10.2 cm) Depth: 1.25" (3 cm) Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 — 32 VDC SLC Standby and Alarm Current Draw: 350 pA End -of -Line Resistance: 47K Q Max. IDC wiring resistance: 1,500 0 Max. IDC Voltage: 11 Volts Max. IDC Current: 450 pA SLC Loop Resistance: 40 Q max. Environmental Operating Temperature: 32°F — 120°F (0°C — 49°C) Humidity: 10% — 93% non -condensing Ordering Information IDP-Monitor Monitoring Module Accessories SMB500 4" Square Surface Mount Electrical Box SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to- date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are KNIGHT subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. by Honeywell For Technical Support, Please call 800-446-6444. www.farenhyt.com 3SILENT KNIGHT O by Honeywell INSTALLATION AND MAINTENANCE INSTRUCTIONS IDP-Monitor-2 Dual Monitor Module Specifications Normal Operating Voltage: 15 to 32 VDC Maximum Current Draw: 5.7 mA (LED on) Average Operating Current: 750pA (LED flashing) EOL Resistance: 47K Ohms Max. IDC wiring resistance: 1,500 Ohms Temperature Range: 32°F to 120°F (0°C to 49°C) Humidity: 10% to 93% Non -condensing Dimensions: 41/2' H x 4" W x 11/4" D (Mounts to a 4" square by 21/8- deep box.) Accessories: SMB500 Electrical Box Before Installing This information is included as a quick reference instal- lation guide. Refer to the control panel installation man- ual for detailed system information. If the modules will be installed in an existing operational system, inform the operator and local authority that the system will be tem- porarily out of service. Disconnect power to the control panel before installing the modules. NOTICE: This manual should be left with the owner/ user of this equipment. General Description The Dual Monitor Module is intended for use in intel- ligent, two wire systems. It provides two independent 2-wire initiating device circuits (IDC), at two separate, consecutive addresses. It is capable of monitoring nor- mally open contact fire alarm and supervisory devices, or either normally open or normally closed security devices. The module has a single panel controlled red LED. Compatibility Requirements To ensure proper operation, this module shall be con- nected to a compatible Silent Knight system control panel (list available from Silent Knight). Mounting Mounts directly to 4" square electrical boxes (see Figure 2A). The box must have a minimum depth of 21/8". Surface mounted electrical boxes (SMB500) are available from Silent Knight. Wiring NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. This module is in tended for power limited wiring only. 1. Install module wiring in accordance with the job draw- ings and appropriate wiring diagrams. 2. Set the address on the module per job drawings. Note: Monitor module L (using terminals 6 and 7) re- sponds at the address set on the code switches. Monitor module H (using terminals 8 and 9) will automatically respond at the next higher address. For example, if the code switches are set to 76, module L will respond at address 76 and module H will respond at address 77. Use caution to avoid duplicate addressing of modules on the system. 3. Secure module to electrical box (supplied by installer), as shown in Figure 2A. Figure 2A. Module mounting: Figure 1. Controls and Indicators: CO218-01 K200-13-00 C0156-00 1 156-2730-002 Figure 3. Typical 2-wire initiating circuit configuration, NFPA Style B: TO NEXT FROM PANEL OR + + PREVIOUS DEVICE DEVICE TWO INITIATING DEVICE CIRCUITS (L & H), EACH POWER LIMITED TO 230µ4 @ 12VDC MAX. F<><:CONNECT MONITOR MODULE MODULES TO LISTED COMPATIBLE SILENT KNIGHT CONTROL PANELS ONLY 47 K EOL "TH 0 O Q (b RESISTOR oIIJJ ��llELR-47K 47 K EOL RESISTOR [:L ELR-47K ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED. DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR SECURITY DEVICES ON THE SAME INITIATING DEVICE CIRCUIT. INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. K200-13-00 9 0 H ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED ®a 358 as 2 El ® 0 as 3 SIGNAL LINE CIRCUIT (SLC) s 2a o„ 32 VDC MAX. SHIELDED -TWISTED PAIR aQ Q IS RECOMMENDED MONITOR A (TERMINALS 6 & 7) RESPONDS AT ADDRESS SET ON CODE SWITCHES. MONITOR B (TERMINALS 8 & 9) RESPONDS AT NEXT HIGHER ADDRESS. C0809-01 SILENT KNIGHT by Honeywell 7550 Meridian Circle Maple Grove, MN 55369-4927 763-493-6455;800-328-0103 Fax:763-493-6475 http://www.silentknight-com © 2006 Silent Knight 2/06 2 156-2730-002 Farenhyt Addressable Single Action and Dual Action Pull Stations IDP-Pull-SA & IDP-Pull-DA The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station. The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 Ibs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble -free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-1/0 surface back box or semi -flush mounted on a standard single -gang with a minimum depth of 2.13"(5.40 cm) or double - gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor® PN BG-TR) trim ring if the station is being semi -flush mounted. SILENT KNIGHT by Honeywell Agency Listings r MEA '• �� 67-02-E Vol. IX Rw ® For IDP-Pull-DA IDP-Pull-SA IDP-Pull-DA Compatibility The IDP-Pull-SA and IDP-Pull-DA are compatible with the following FACPs: • IFP-2000 / RPS-2000 Intelligent Fire Panel • IFP-1000 / ECS Intelligent Fire Panel • IFP-100 / ECS Intelligent Fire Panel • IFP-50 Intelligent Fire Panel P/N 350286 Rev F © 2013 Honeywell International Inc Compatible FACP Class A Wiring: Class B Wiring: Class A ..................................................................... Class B ,� enn NOR 0 I �. Wiring IDP-Pull-SA & IDP-Pull-DA Pull Stations Specifications* Physical Height: 5.5" (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 321- 120°F (0°C - 49°C) Humidity: 10% — 93% non -condensing Ordering Information IDP-Pull-SA Single Action Pull Station IDP-Pull-DA Dual Action Pull Station Accessories BG-TR Optional trim ring. SB-1/0 Surface backbox, indoor/outdoor. Unless otherwise noted, specifications apply to IDP-Pull-SA and IDP-Pull-DA. SILENT This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications KNIGHT or anticipate all requirements. All specifications are subject to change without notice. 13c) For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472- by Honeywell 1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com Made in the U.S.A. 4,�� SYSTEM Indoor Selectable - Output Strobes and Horn Strobes for Ceiling Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on ceiling units: 15, 30, 75, 95, 115, 150, and 177 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices • Compatible with MDL3 sync module • Listed for ceiling mounting only Agency Listings SIGNALING & F M LISTED APPROVED 55512 FM approved except 7125-1653:0504 54011 for ALERT models 7135-1653:0503 3057383 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling -mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. AVDS868-02 - 12/01/2017 • Page 3 L-Series Specifications General L-Series ceiling -mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double - gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling -Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high) Ceiling -Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS868-02. 12/01/2017 • Page 2 UL Current Draw Data RIJNMFVf1RjM- T.i. nja;' 1IFFSL*Irii1MECi11 L max. 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16--,33 Volts Candela DC DC FWR Sound Pattern dB DC DC FWR Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non -Temporal High 43 47 54 95 N/A 134 164 Non -Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non -Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.11K Non -Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non -Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non -Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.11K Non -Temporal High 108 135 179 200 225 255 289 3.1 K Non -Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn .: 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 AVDS868-02 • 12/01/2017 • Page 3 L-Series Dimensions 0.83" di (173 n 2.47" (62.7 mm) 1.37" (34.8 min) Ceiling -Mount Horn Strobes A0545-00 A0494-01 6.92" r+— (175. Ceiling Surface Mount Back Box 2-Wire Ceiling Mount Horn Strobes 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories 2.5' (64 mm) O A0546-00 TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCWL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling -listed horn -only device, see AVDS865 "Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications". 1-01 SYSTEM ©t to c System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemsensoccom SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,6,-02ngthe latestversion ofthisdata sheet. AVDS868-02 • 12/01/2017 4,�� SYSTEM Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features 2 • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only Agency Listings SIGNALING & F M LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057383,3057072 011 The System Sensor L-Series offers the most versatile and easy -to -use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. L-Series Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double -gang back box. L-Series compact products shall mount to a single -gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit'M Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR' 2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 1.91-D 043 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.25-D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25" D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data UL Max. Strobe Current Draw (rnA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Candela 15 88 43 60 Temporal High 39 44 54 Range 30 143 63 83 Temporal Low 28 32 54 75 N/A 107 136 Non -Temporal High 43 47 54 95 N/A 121 155 Non -Temporal Low 29 32 54 110 N/A 148 179 3.1 KHz Temporal High 39 41 54 135 N/A 172 209 3.1 KHz Temporal Low 29 32 54 185 N/A 222 257 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 Max. Current Draw (rnA DC Input RMS), 2-Wire 8-17.5 Volts 15cd Strobe,UL Horn 30cd 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1 K Temporal High 93 156 53 73 119 140 164 190 242 3.1 K Temporal Low 91 154 45 66 112 133 160 185 235 3.1 K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1 K Non -Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1KTemporal High 81 105 155 177 196 234 284 3.1 K Temporal Low 68 90 145 166 186 222 276 3.11K Non -Temporal High 104 131 177 204 230 264 326 3.1 K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9" Coded High 85 90 90 10" 3.1 KHz Coded High 84 89 89 . Settings 9 and 10 are not available on the 2-wire horn strobes. L-Series Dimensions 1.y1 3.46 1.25 0 0°000°0°U°0 a0a°a°o°o°oOo 0000000000000 5.27 �I 0 Compact Strobe / Horn Strobe 4.70 1.91 1.25 5.67 Strobe / Horn Strobe L-Series Ordering Information 5 3.46 1.25 0°0°o°0° 00000000e0000 0000000000000 o0a0000000000 000'0000000o0 27 ° a°o°a°a°o°a0• a°o°o°o°o°a°a ooa000000000a oa000ao°o°oaa o aaaaaoaaaaa 0 Compact Horn Horn Wall Horn Strobes Horns P2RL 2-Wire, Horn Strobe, Red HRL Horn, Red P2WL 2-Wire, Horn Strobe, White HWL Horn, White P2GRL 2-Wire, Compact Horn Strobe, Red HGRL Compact Horn, Red P2GWL 2-Wire, Compact Horn Strobe, White HGWL Compact Horn, White P2RL-P 2-Wire, Horn Strobe, Red, Plain Accessories P2WL-P 2-Wire, Horn Strobe, White, Plain TR-2 Universal Wall Trim Ring Red P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO TR-2W Universal Wall Trim Ring White P2WL-SP 2-Wire, Horn Strobe, White, FUEGO SBBWL Wall Surface Mount Back Box, Red Wall Strobes SBBWL Wall Surface Mount Back Box, White SRL Strobe, Red SBBGRL Compact Wall Surface Mount Back Box, Red SWL Strobe, White SBBGWL Compact Wall Surface Mount Back Box, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO" marking on cover All -ALERT models have "ALERT' marking on cover 3825 Ohio Avenue • St. Charles, IL 60174 ©2017SystemSensor. SYSTEM Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit systemsensorcom SENSOR` or current product information, including the latest version of this data sheet. www.systemsensor.com nvosassoa • 03n7 4,�� SYSTEM Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING O L F M MEA 7300-1653:187 (outdoor strobes) LISTED approved 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) APPROVED pp chime strobes) S3593 (outdoor and alert strobes) 3N,'F79 MEA452-05-E 7135-1653:189 (horns, chimes) AIL 0 pf'r S y s t e m S e n s o ar SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitT" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 °F (-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) MIMEr "MIRIMM, I 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL ..Candela 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current •Strobe, DC Input High 16-33 Volts 135 150 177 Candela 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 wit 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output •8-17.5 candela ratings must be reduced in accordance with 16-33 24-Volt Nominal this table. S h S d Volts Volts Reverberant Anechoic StrobeOutput Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 c Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 rAlert Advance Diagrams 2.5" 3„ Wall -Mount Horn Strobes IMP U erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK`t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK•t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK"t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK't Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK•t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: Add '-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. f_ SYSTEM ©t to change System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Produc specifications subject02SysmSentnotice. Visit systemsensoccom SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,DS01 01.3/atestversionofthisdaasheet. AVDS01201 • 3/12 4,�� SYSTEM Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert® Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from —40°F to 151 °F • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper -resistant construction • Listed for ceiling or wall mounting Agency Listings SIGNALING O L F M MEA 7300-1653:187 (outdoor strobes) LISTED approved 7125-1653:188 (horn strobes, S4011 (chimes, horn strobes, horns) APPROVED pp chime strobes) S3593 (outdoor and alert strobes) 3N,'F79 MEA452-05-E 7135-1653:189 (horns, chimes) AIL 0 pf'r S y s t e m S e n s o ar SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from —40oF to 151 °F. Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24-volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater corrosion. Knock -outs located on the back eliminate the need to drill holes for screw -in mounting. Plastic and metal weatherproof back boxes come with 3/4-inch top and bottom conduit entries and 3/4-inch knock -outs at the back. A screw -in NPT plug with an 0-ring gasket for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•CircuitT" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Operating Temperature -40°F to 151 °F (-40oC to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (including lens) 5.6-L x 4.7-W x 2.5-D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7-L x 5.1-W x 2.0-D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non -regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max. Strobe Current Draw (mA RMS) MIMEr "MIRIMM, I 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non -Temporal High 57 56 69 75 95 NA NA 181 176 Non -Temporal Medium 42 50 60 69 110 NA NA 202 195 Non -Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 Max. Current Draw (mA RMS), 2-Wire Horn Strobe,UL ..Candela 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low 132 154 80 90 105 161 184 202 211 UL Max. Current •Strobe, DC Input High 16-33 Volts 135 150 177 Candela 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 wit 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output •8-17.5 candela ratings must be reduced in accordance with 16-33 24-Volt Nominal this table. S h S d Volts Volts Reverberant Anechoic StrobeOutput Listed Candela Candela rating at —40°F 15 Do not use below 32°F 15/75 30 75 44 95 70 110 110 115 115 135 135 150 150 177 177 185 1185 c Position oun Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal Low 71 73 76 76 83 80 94 89 4 Non- Temporal High 82 82 88 88 93 92 100 100 5 Non- Temporal Medium 78 78 85 85 90 90 98 98 6 Non- Temporal Low 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobe. AVDS01201 rAlert Advance Diagrams 2.5" 3„ Wall -Mount Horn Strobes IMP U erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Wall Horn Strobes P2RK`t 2-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK't 2-Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK"t 2-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK•t 2-Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4-Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe, High cd, Red, Outdoor, 120 V (includes plastic weatherproof back box) Wall Strobes SRK"t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK't Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK•t Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK*t Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Horns HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WBB Red, Metal Weatherproof Back Box SA-WBBW White, Metal Weatherproof Back Box Notes: Add '-P" to model number for plain housing (no "FIRE" marking on cover), e.g., P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. f_ SYSTEM ©t to change System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Produc specifications subject02SysmSentnotice. Visit systemsensoccom SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 or current product information,DS01 01.3/atestversionofthisdaasheet. AVDS01201 • 3/12 TELGUARD AMETEK° �l Telguard Portal Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7. This advanced tool has multi -level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. TG-7FS LTE COMMERCIAL FIRE CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS PRODUCT FEATURES f Certified for use on the AT&T or Verizon LTE networks for sunset -free installations. f Meets UL 864 requirements for sole, primary or backup path communications. f Minimizes false alarms by providing dual paths for self -tests. The Telguard TG-7FS LTE is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG- 7FS LTE can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user r significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE because of the new five or sixty minute supervision modes. The TG-7FS LTE can also be installed as a backup path and upgraded to sole path at a later date. Telguard Cellula v " Telguard Cellular Service provides nationwide LTE network coverage for all Telguard units. Telguard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. Advanced Reliability • Features the ability to utilize multiple cellular technologies to increase availability and reduce false alarms. • Automatic self -tests with central station notification ensure the cellular system is operating. • Available relay output for tripping the alarm control panel when a trouble condition occurs. TELGUARD AMETEK° Power • Transmit Power: 200 mW in all bands. • Power Consumption: 40mA (Standby) 160mA (Transmission) with link supervision enabled. • Source: 12VAC, 800mA UL listed plug-in transformer (included), or 24VDC from panel with TG-PEM accessory. Radio Transceiver • LTE Bands: AT&T: 2, 4, 5, and 17 Verizon: 4 and 13.v • Antenna Port: SMA, 50-Omh. • FCC part 15, 22, 24, 27 and 68 compliant. Physical Details r �_l • Size (without antenna): 7.5" H x 11.5" W x 3.5" D (19.05cm H x 29.21cm W x 8.89cm D). • Shipping Weight (with transformer): 8lbs (3.63kg). • Operating Environment: 0°C to +50°C; up to 95% humidity (non -condensing). Standard Features • Full data reporting. • Automatic self -test (5 or 60 minute, and daily). • Locking, red metal enclosure. • Two programmable supervisory trip outputs. • Alarm format support for SIA2, Contact ID, pulse (3x1, 4x2), modem Ile, & Illaz, DMP. • Telephone line monitor built-in, with Standard Line Security. TG-7FS LTE CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS 04 LTE ® Netwo rk Alarm Panel TG-IFS C LTE _a i e (opt""l) _-1Telguard Comnietio reter ' I Central Station Fire Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for superior in -building penetration. Telguard products are easy to install, economical, and UL Listed. Accessories • TG-PEM: Power & Expansion Module for powering the TG-7FS from 24V DC alarm panel; no need to have an electrician install a dedicated outlet. • ACID 12, ACID 35, ACID 50, ACID 100: 12/35/50/100 feet of low loss, high performance cable. • HGDL-0: High gain directional antenna. • EXDL-0: External antenna. UL Listings: AT&T and Verizon Commercial Fire Commercial Burglary Residential 864 • Control units & 365 Police Station 985 • Household fire accessories for fire connected burglar warning systems alarm systems alarm units and 1023 • Household burglar systems alarm systems 1610 • Central station burglar alarm units; Line security servcies ULC Listings: AT&T Only S545 Canadian household fire warning systems S304 Canadian commercial burglary alarm systems S559 Equipment for fire signal receiving centres and systems C1023 • Canadian household burglary alarm systems * For the most current product specifications and UL Listings visit www.Teiguard.com. SECURITY SIGNA ING ELECTRONIC J.•��• CSlus ® % AsEcuR TY SSOCIATION"" Verizon network certified NFPA //Il\ Executive Strategic Partner Connected LISTED ;,00,;oz INTERNATIONAL Gold by AT&T 800.229.2326 13225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA I telguard.com ©2020 Telguard is a brand of Telular Corporation I Telular is a business unit of AMETEK, Inc • All Rights Reserved 032020RevB