APPROVED FIR2022-0028+Fire_Alarm_Plan+3.16.2022_10.33.39_AM+2740851
Symbol Legend SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MODEL QUANTITY FACP INTELLIGENT FACP RED FARENHYT IFP-300 IFP-300 1 DACT CELLULAR RADIO NETWORK TELGUARD/ TELULAR TG-7FS TG-7FS 1 FA, LCD REMOTE LCD ANNUNCIATOR, RED FARENHYT RA-1000R RA-1000R 1 (1 3 SMOKE, PHOTO, ADD, WHITE, LOW PROFILE FARENHYT IDP-PHOTO-W IDP-PHOTO-W 4 ( j ) HEAT, FIXED 135, ADDRESSABLE FARENHYT IDP-HEAT IDP-HEAT 1 (1 j 135 °F (57° C) DUAL CIRCUIT FIXED TEMPERATURE SYSTEM SENSOR 5623 5623 1 AIM 1 INTERFACE MODULE, ADDRESSABLE FARENHYT IDP-MONITOR IDP-MONITOR 2 e2- DUAL MONITOR MODULE FARENHYT IDP-MONITOR 2 IDP-MONITOR-2 2 el RELAY MODULE, ADDRESSABLE FARENHYT IDP-RELAY IDP-RELAY 3 nPULL STATION, DOUBLE ACTION, ADDRESSABLE FARENHYT IDP-PULL-DA IDP-PULL-DA 1 EL-SERIES 2-WIRE, HORN STROBE, RED, WALL SYSTEM SENSOR P2RL P2RL 1 (N L-SERIES 2-WIRE, HORN STROBE, RED, CEILING SYSTEM SENSOR PC2RL PC2RL 8 LSERIES STROBE, 2 WIRE, M-C, RED, CEILING SYSTEM SENSOR SCRL SCRL 3 /O\ WF HORN/STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR SYSTEM SENSOR P2RK P2RK 1 STROBE, 2 WIRE, M-C, RED, CEILING, WEATHERPROOF SYSTEM SENSOR SCRK SCRK 1 �O� WP ® 4.7K Q EOL 4.7K FARENHYT EOL-4.7 EOL-4.7 4 Circuit Calculations Panel: FACP Card: 00 Circuit:SIG4 Circuit Name: SIG4 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 3.000OA Cable: 14/2 SOL JKT FPLR 1 M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 1671F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop IFP-300 Panel 20AV 1 PC2RL L-SERIES 2-WIRE, HORN STROBE, RED, CEILING, 15CD 35'-0 69.0000mA 20.3072V (0.0928V) 2 PC2RL L-SERIES 2-WIRE, HORN STROBE, RED, CEILING, 15CD 8'-0 69.0000mA 20.2893V (0.0178V) 3 PC2RL L-SERIES 2-WIRE, HORN STROBE, RED, CEILING, 75CD 27'-0 147.000OmA 20.2406V (0.0487V) 4 PC2RL L-SERIES 2-WIRE, HORN STROBE, RED, CEILING, 75CD 44'-0 147.0000mA 202009V (0.0397V) 4 EOL-4.7 EOL 4.7K 3-0 0.0000mA 202009V (OV) 11 T-0 432.0000mA Total Current: 432.0000mA (Total VDrop Percent:0.98%) Total Voltage Drop: 0.1991V Circuit Calculations Panel: FACP Card: 00 Circuit:SLC Circuit Name: SLC Circuit Type: Signaling line/IDP - SLC Terminal Voltage: 20.2V:DC Amperage: 1.000OA Cable: 18/2 SOL OAS FPLR 1 M BX RED #18 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop IFP-300 Panel 20.2V SA IDP-PHOTO-W SMOKE, PHOTO, ADD, WHITE, LOW PROFILE 3'-0 0.2000mA 20.1996V (0.0004V) M:1 IDP-PULL-DA PULL STATION, DOUBLE ACTION, ADDRESSABLE 4'-0 0.3501 20.1995V (0.0001V) M:2, 3 IDP-MONITOR 2 DUAL MONITOR MODULE 4'-0 0.7500mAj 20.1994V (0.0001V) MA 5 IDP-MONITOR 2 DUAL MONITOR MODULE T-0 0.7500mA 20.1994V (OV) S:2 IDP-PHOTO-W SMOKE, PHOTO, ADD, WHITE, LOW PROFILE 33-0 0.2000mA 20.1962V (0.0034V) 3 IDP-HEAT HEAT, FIXED 135, ADDRESSABLE 16'-0 0.3000mA 20.1953V (0.0009V) M:6 IDP-MONITOR INTERFACE MODULE, ADDRESSABLE 2'-0 2.5000mA 20.1952V (0.0001V) M:7 IDP-RELAY RELAY MODULE, ADDRESSABLE T-0 0.2600mA 20.1951V (OV) M:8 IDP-RELAY RELAY MODULE, ADDRESSABLE T-0 0.2600mA 20.1951V (OV) M:9 IDP-RELAY RELAY MODULE, ADDRESSABLE 2'-0 0.2600mA 20.1951V (OV) SA IDP-PHOTO-W SMOKE, PHOTO, ADD, WHITE, LOW PROFILE 40'-0 0.2000mA 20.1944V (0.0018V) S:5 IDP-PHOTO-W SMOKE, PHOTO, ADD, WHITE, LOW PROFILE 21'-0 0.2000mA 20.1935V (0.0009V) M:10 IDP-MONITOR INTERFACE MODULE, ADDRESSABLE 15'-0 2.5000mA 20.1929V (0.0006V) 145'-0 8.7300mA Total Current: 8.7300mA (Total VDrop Percent:0.04%) Total Voltage Drop : 0.0071 V Battery Calculations for Panel: FACP Part No:IFP-300 - INTELLIGENT FACP RED Part No. Qty. Description Standby Total Standby Alarm Total Alarm Panel Equipment IFP-300_MB 11 IFP-300 INTELLIGENT MAIN BOARD 190.000OmA 190.0000mA 250.000OmA 250.000OmA Total Panel Stby 190.000OmA Total Panel Alarm 250.000OmA Peripheral Devices P21RK 1 HORN/STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR (Notification) 110CD 88dB 0.000OmA 0.0000mA 221.0000mA 221.000OmA EOL-4.7 4 EOL 4.7K (Notification) 0.000OmA 0.0000mA 0.0000mA 0.000OmA SCRL 3 L-SERIES STROBE, 2 WIRE, M-C, RED, CEILING (Notification) 15CD 0.000OmA 0.0000mA 41.0000mA 123.000OmA PC2RL 4T L-SERIES 2-WIRE, HORN STROBE, RED, CEILING (Notification) 75CD 88dB 0.000OmA 0.000OmA 147.000OmA 588.000OmA PC2RL 1 31 L-SERIES 2-WIRE, HORN STROBE, RED, CEILING (Notification) 15CD 88dB 0.000OmA 0.000OmA 69.000OmA 207.000OmA SCIRKI 1 1 STROBE, 2 WIRE, M-C, RED, CEILING, WEATHERPROOF (Notification) 75CD 0.000OmA I 0.0000mA 158.000OmA I 158.000OmA PC2RL 1 11 L-SERIES 2-WIRE, HORN STROBE, RED, CEILING (Notification) 30CD 88dB 0.000OmA I 0.0000mA 94.000OmA I 94.000OmA P2RL 1 L-SERIES 2-WIRE, HORN STROBE, RED, WALL (Notification) 30CD 88dB 0.000OmA 0.000OmA 73.000OmA 73.000OmA RA-1000R 1 REMOTE LCD ANNUNCIATOR, RED (Power) 20.000OmA 20.000OmA 25.000OmA 25.000OmA RA-1000R 1 REMOTE LCD ANNUNCIATOR, RED (Serial) 0.1000mA 0.1000mA 0.1000mA 0.1000mA IDP-PHOTO-W 4 SMOKE, PHOTO, ADD, WHITE, LOW PROFILE (Signaling line) 0.2000mA 0.8000mA 4.5000mA 18.000OmA IDP-MONITOR 2 2 DUAL MONITOR MODULE (Signaling line) 0.7500mA 1.5000mA 0.7500mA 1.5000mA IDP-HEAT 1 HEAT, FIXED 135, ADDRESSABLE (Signaling line) 0.3000mA 0.3000mA 6.5000mA 6.5000mA IDP-MONITOR 2 INTERFACE MODULE ADDRESSABLE (Signaling ( 9 9 line) 2.5000mA 5.000OmA 22500mA 4.5000mA IDP-RELAY 3 RELAY MODULE, ADDRESSABLE (Signaling line) 0.2600mA 0.7800mA 0.0260mA, 0.078OmA IDP-PULL-DA 1 PULL STATION, DOUBLE ACTION, ADDRESSABLE (Signaling line) 0.3500mA 0.3500mA 0.3500mA 0.3500mA Total Peripheral Stby 28.8300mA Total Periph Alarm 1520.0280mA Total Standby Amps 218.8300mA Total Alarm Amps 1770.0280mA Standby time: 24 Hrs 5.252Ah Alarm time: 5 Min 0.148Ah Battery requirement: 5.399Ah Compensation Factors - Standby: 1.2 Alarm: 1.2 Requirement with compensation: 6.479Ah Circuit Calculations Panel: FACP Card: 00 Circuit:SBP1 Circuit Name: SBP1 Circuit Type: Power/SBUS RS-485 Terminal Voltage: 20.2V:DC Amperage: 1.0000A Cable: 14/2 SOL JKT FPLR 1 M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167oF Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop IFP-300 Panel 20.2V RA-1000R REMOTE LCD ANNUNCIATOR, RED 22'-0 20.000OmA 20.1973V (0.0027V) 22'-0 20.000OmA Total Current: 20.000OmA (Total VDrop Percent: 0.01 %) Total Voltage Drop: 0.0027V Circuit Calculations Panel: FACP Card: 00 Circuit:SIG1 Circuit Name: SIG1 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 3.000OA Cable: 142 SOL JKT FPLR 1 M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167'F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop IFP-300 Panel 20AV 1 P2RK HORN/STROBE, 2 WIRE, STANDARD CD, RED, OUTDOOR, 110CD 22'-0 221.000OmA 20.3701V (0.0299V) 1 EOL-4.7 EOL 4.7K 5'-0 0.000OmA 20.3701 V (OV) 27'-0 221.000OmA Total Current: 221.000OmA (Total VDrop Percent: 0. 15%) Total Voltage Drop: 0.0299V Circuit Calculations Panel: FACP Card: 00 Circuit:SIG2 Circuit Name: SIG2 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 3.000OA Cable: 14/2 SOL JKT FPLR 1 M RL RED #14 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167'F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop IFP-300 Panel 20AV 1 PC2RL L-SERIES 2-WIRE, HORN STROBE, RED, CEILING, 75CD 10'-0 147.000OmA 20.3727V (0.0273V) 2 SCRL L-SERIES STROBE, 2 WIRE, M-C, RED, CEILING, 15CD 25'-0 41.000OmA 20.3269V (0.0457V) 3 PC21RL L-SERIES 2-WIRE, HORN STROBE, RED, CEILING, 15CD 23'-0 69.0000mA 20.2906V (0.0363V) 4 SCRL L-SERIES STROBE, 2 WIRE, M-C, RED, CEILING, 15CD 27'-0 41.000OmA 20.2595V (0.0312V) 5 PC2RL L-SERIES 2-WIRE, HORN STROBE, RED, CEILING, 75CD 24'-0 147.0000mA 20.2378V (0.0217V) 005 EOL-4.7 EOL 4.7K 3-0 0.000OmA 20.2378V (OV) 117-0 445.000OmA Total Current: 445.000OmA (Total VDrop Percent: 0.80%) Total Voltage Drop: 0.1622V Circuit Calculations Panel: FACP Card: 00 Circuit:SBC1 Circuit Name: SBC1 Circuit Type: Serial/SBUS RS-485 Terminal Voltage: 4.2V:DC Amperage: 1.0000A Cable: 16/4 SOL JKT FPLR 5C RL RED #16 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167'F Max. operating voltage drop: 10% Device Part No Appliance Desc Distance Current Voltage Voltage Drop IFP-300 Panel RA-1000R REMOTE LCD ANNUNCIATOR, RED 22'-0 0.1000mA Circuit Calculations Panel: FACP Card: 00 Terminal Voltage: 20.4V:DC Amperage: 3.000OA Cable: 14/2 SOL JKT FPLR 1 M RL RED #14 Calculations based on Lump Sum Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 10% Circuit Description Type Total Len P2RL, 30CD, 73.000mA SCRL, 15CD, 41.000mA PC2RL, 30CD, 94.000mA SCRK, 75CD, 158.000mA EOL-4.7 Total Amps Gauge V Drop % V Drop Resistance Max Len SIG3 Notification 80'-0 1 1 1 1 1 366.0000mA 1 #14 0.88 0.1798V 0.5 Ohms 90T-0 FIRE ALARM SYSTEM OPERATIONAL MATRIX ALARM TROUBLE SUPERVISORY misc. 20 �' i.0� k QO� 110 �� =6 �� I v co 0 �CID CIO?J tC� ��2� Q J` �?� mv� t� �Q2 JQm J Q _Q ge O�� JO i. /.� �� �Q S�J �VQ ��y O O O �� IT �� �T �� 2 `0 G ti CAUSE .� v� ,� ,� ,� r, r, r, 4 �, p p C-2 SMOKE DETECTORS • • • • • ELEVATOR SMOKE 1ST FLOOR • • • • • • • ELEVATOR SMOKE 2ND FLOOR • • • • • • • HEAT DETECTORS • • • • • MANUAL PULL STATIONS • • • • • SYSTEM RESET • • • SIGNAL SILENCE • • AC POWER FAILURE • • • TROUBLE (OPEN, SHORT, GROUND) • • • TAMPER SWITCHES • • • WATERFLOW SWITCH • • • 1 • • SYSTEM NOTES: 14/2 75CD 15CD 15CD EOL 4.7K 075CD 01 H H H H bL Dry of Approved by Fire 04/07/2022 AFM FC-FLtterer Need a Knox Box at entry to lobby S S AIM 2 �• C12• ,. �U �O G (V 14/2 WP 75CD 3!15CDCD 3 EOL 4.7K 0\ / H \ /�0CD O 02 1412 1612 TG-7FS EOL 4.7K 075CD �SC� 15CD �SC� 75CD IH H H S F AIM AIM UIH �v �v 14/2 FACP LCD EOL 4.7K 0 WP 110CD FAA N0/ _ G +. �`� • y�Cl ((AA� .05 0 C; Cif 41 CV �v 20 AMP DEDICATED CIRCUIT Area 0 WIRING DIAGRAM GENERAL NOTES / SCOPE OF WORK 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANYALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATICAND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSTALLATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F. P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHTTO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. FIRE SYSTEMS WEST WILL INSTALLA NEW FIRE ALARM CONTROL PANEL, COMMUNICATOR, AND FIRE ALARM ANNUNCIATOR. 8. FIRE SYSTEMS WEST WILL INSTALL NEW SMOKE DETECTORS FOR ELEVATOR RECALL. 9. FIRE SYSTEMS WEST WILL INSTALL NEW ADDRESSABLE INPUT MODULES TO MONITOR THE SPRINKLER RISER. 10. FIRE SYSTEMS WEST WILL INSTALL NEW NOTIFICATION DEVICES THROUGHOUT. CODE COMPLIANCE OCCU PANT TYPE: A-21 A-3 OCCUPANT LOAD: 420 AREA: 51660 SF CONSTRUCTION: V B SPRINKLERED APPLICABLE CODES: CITY OF EDMON DS MUNICIPAL CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL FIRE CODE 2020 NATIONAL ELECTRICAL CODE 2019 NATIONAL FIRE ALARM AND SIGNALING CODE VICINITY SCALE: N.T.S. B 16/2 FPLP EX EXISTING LOCATION D DEMO DEVICE N NEW DEVICE R RELOCATE STROBE COVERAGE AREA SHALL BE DEFINED AS 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20'X20' 30 cd = 30'x30' 75 cd = 30'x30' 95 cd = 30X30' 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 40'x40' 95 cd = 50'x50' 110 cd = 50X50' 115 cd = 50'x50' Drawing re'Viewe d b : MattCarlman IVICET Cerd ic.ation -No. 1 053 Fire AL= Sy. stems - Level III CertiScation Expires: N ovember 0l, 2023 E-mail: maftc&Eresystemswestcom Phone: 253-951-6005 WORKAREA Grace Lutheran Ch h Edmonds O Elemen,ary School Edmonds Food Bank I I V DF ED DS Holy7hurch ♦w^'s £ Edmonds Center Forthl Arts ce^s �^- mma - s I iked's Dw d' x z .x.as Emerald HillsQ z ndi 13 North a „p� 10 mills RivarolaQ Rory s of Edmindae /� �Ms1 Edm1n Sil Ferry rerminal z etlls z\ • S Edmonds Mraln SL 1 dmods, WA 98020 oepe.A DWI.% Den.. sr oe nsr �� uae,w .u-w N .�aas € a.,s vost PoolQ Walnut Street Cotfeee wens Welts st "jam a' d,PPerkTennis \ c leliell Courts ehelNbeyer � eoiryw caass � Isnn 3 ' �:L $ s fEd'- N • O O 00 C7 LO � L-4 N 00 � a I� (� t- N O N co C7 00 CO J U U � m 0 N N W 0 N uO co M Z 0 O W ujo w 1- OfI D- Of O U W w o Z 2 r• C) z 02 D_ � co co ZZ Z O LLI ¢ � �! zmz w o ?:: ¢ 0 CD 0 - cocr- z W >-L Uj ( Q Lu Q U- Z Cn Z C) C w 0 E 0[ 0 LL co K N FIR2022-0028 RECEIVEI 3/1 6/2; CITY OF EDMONDS DEVELOPMENT LO 00 Z N o o N E �(AO0D O U >_ N o) Q AMACQ g LLI IOC x "n0 }' O _ L-L •U It E 0 1 0�NW O 0 Z N J N ::D E E Cl) LLJ N .__. E5 Cl) 2 z � O 2 N o C04 OE O a.., 0) ,E I_ oO �U� U z�.-� w Q 0 I` 2 O 1 o'@I-0 z O 02L1')w (I N CD O 0 r 0 l LO I I ¢' CIOo I- LU LU LU Q Q LU o GENERAL NOTES / SCOPE OF WORK • �' o o 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE 00 L7 p REQUIREMENTS. ANYALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT co ELECTRICAL CONTRACTOR'S OWN RISK!! Z ' Rco 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATICAND ONLY USED FOR to 04 N W 04 REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSTALLATION MAY VARY DUE TO `� cd w OBSTRUCTIONS. c a 0 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE 00 W PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME N RACEWAY. Co r--I N m 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., c`') 00 N.F. P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY m N o AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHTTO SUBSTITUTE +� EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE w CIRCUITS SHALL NOT BE PERMITTED. i 7. FIRE SYSTEMS WEST WILL INSTALLA NEW FIRE ALARM CONTROL PANEL, COMMUNICATOR, AND FIRE ALARM ANNUNCIATOR. •� U k 8. FIRE SYSTEMS WEST WILL INSTALL NEW SMOKE DETECTORS FOR ELEVATOR RECALL. U U 9. FIRE SYSTEMS WEST WILL INSTALL NEW ADDRESSABLE INPUT MODULES TO MONITOR THE SPRINKLER RISER. 10. FIRE SYSTEMS WEST WILL INSTALL NEW NOTIFICATION DEVICES THROUGHOUT°�° OU CODE COMPLIANCE co Z W QLo o; N N O 0 OCCU PANT TYPE: A-21 A-3 o w OCCUPANT LOAD: 420 �o a w �I ' O $ IG3.1 ICE CREAM STORAGE AREA: 51660 SF (n w OI Lu ' 30CD TENANT 5 - UNOCCUPIED Lu ICE CREAM PREP H 3aCD CONSTRUCTION: V B SPRINKLERED — TENANT 4 - OCCUPIED z APPLICABLE CODES: CITY OF EDMON DS MUNICIPAL CODE 2018 INTERNATIONAL BUILDING CODE PONY WALL / SIG3.4 SIG2 SIG2.5 H 2O18 INTERNATIONAL FIRE CODE o z ~ Co /75CD 4.7K S� 75CD 2020 NATIONAL ELECTRICAL CODE �� Q co z O w o f- / SIG3.2 2019 NATIONAL FIRE ALARM AND w z �� J— Q ICE CREAM SERVING 15CD / ` SIGNALING CODE Cn Oz ¢ w w cn TO FACP �■ $IG3 4.7K 0 a A 14/2 FPLP B 16/2 FPLP Lu �� QU �z Q < cn z U of of LL � N C x EX EXISTING LOCATION D DEMO DEVICE N NEW DEVICE FIR 022-0028 TENANT 3 - UNOCCUPIED R RELOCATE I I STROBE COVERAGE AREA SHALL BE DEFINED AS IRECEIVED 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20'x20' I3/16/22 30 cd = 30'x30' 75 cd = 30'x30' 95 cd = 30'x30' 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 40'x40' 95 cd = 50'x50' 110 cd = 50'x50' 115 cd = 50'x50' CITY OF EDMONDS DEVELOPMENT ERVICES DEPARTMEN SIG 2.1 � H \' � 75CD Hill MEWS RR / SIG2.4 15CD Q N FIRE RISER ROOM LOBBY o o N E Lq _ V co OD U $LC•M:V AIM OM WWI Q O SIG2.3 15CDH SLCe3 oM 1: 1 0� CaQ Lc SLC.S. y OMEN R wo -D ❑ S n CL LC•M:9 OC LO on o _ LL •UMW O SLC•M:1 N F INSTALL RELAYS FOR ELEVATOR RECALL / SIG2.2 SL •S:2 LIE z • LC M. AIM INSTALL INPUT MODULE FOR ELEV. SHUNT o m 2 / 15CD •0 WORKAREA E • U P LC M. AIM 2 FAA ELECTRICAL ROOM 7' x° _ tl°ns ®Tranalt P Parkiiq Pharmacies mATMe a„°ew.r `V E o u—a � uomr aR Grace Lutheran Gh h OElemeMa _ Elementary School new= ewe wawa.. wM+ r _ � I m..a {0 110CD 'p' a w.a w w SIG 1.1 Edmonwds .dBankQ rr� Wp a S THE BO L �I OF ED DS max° u) N Lo tea' Holy ROSdry Church 4Rn'a \\ EdmandsGmter ,.....x 19 ..s �A p �/ •s_ C G r 0 SIG1 For the s° m9 kett's owra �' a z °xws Emerald HillsQ tl Hodh coo 17114 o U w Q 4.7K Q / a w\ Vllla RivarolaQ 0 Q �(((, �,�Rorys of Etlmantls - \ eemm°.a sem ' S ', E (D ¢ z •5 /� ©Salt and Iron S 'aY enis g > 4 l EdmoMs� Edmdn Sil Ferry Terminal z eels z\ s y Edmonds Main dmonds, WA 980]0 . O L }I p EAST BUILDING MAIN LEVEL Iq w°� A� N � H b S9ua rn.w.9 N M i.s v AthlHlcGlub� uw,s ^uea nieces g aaaa Yost PoolQ .,,` C) �// o `�J .� E ' :� nn`� Walnut Street Coffee ek. t lr Ennis cen S wehus WelnN st � d,kPlckeliall Cauris Edmonds ehelNbeyer xoihn' caws % '+:_ Mersh ~ O ig Z 1 o Y/ C) _ • L O L 0' 2' 4' 6' 12' 20' .h w n ; £ SCALE: 1/4��=1�_0�� P.*--�m�'`'°° ��°ryPa° �� „aHw each Edmonds N ww\ r.ws ...,,. "' `) O N ' N E E C a °i Erma % nd n ' � I Q (0 ) w s � r� � nw Edwa s Pot�� � ... . . lnt 1 W��y� co O f L 1 Lu Lu ll-� VICINITY Lu o w O Cn U) J SCALE: N.T.S. I GENERAL NOTES / SCOPE OF WORK • �' 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE o o 00 L7 p REQUIREMENTS. ANYALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT co ELECTRICAL CONTRACTOR'S OWN RISK!! Z Rco 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATICAND ONLY USED FOR ' LO W 04 N 04 REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSTALLATION MAY VARY DUE TO `� w Cd OBSTRUCTIONS. c a 0 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE 00 W PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME N Co RACEWAY. r--I N m 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., C`') 00 N.F. P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. m 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY N77� o AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHTTO SUBSTITUTE +� EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE w CIRCUITS SHALL NOT BE PERMITTED. i 7. FIRE SYSTEMS WEST WILL INSTALLA NEW FIRE ALARM CONTROL PANEL, COMMUNICATOR, AND FIRE ALARM ANNUNCIATOR. •� U k 8. FIRE SYSTEMS WEST WILL INSTALL NEW SMOKE DETECTORS FOR ELEVATOR RECALL. _ TERRACE 9. FIRE SYSTEMS WEST WILL INSTALL NEW ADDRESSABLE INPUT MODULES TO U MONITOR THE SPRINKLER RISER. 10. FIRE SYSTEMS WEST WILL INSTALL NEW NOTIFICATION DEVICES THROUGHOUT. m 0 0 N N W QLO 0 CODE COMPLIANCE o; W Z 0 � o w OCCU PANT TYPE: A-21 A-3 IL Ixo w OCCUPANT LOAD: 420 F IX E XI O U AREA: 51660 SF w � w o CONSTRUCTION: V B SPRINKLERED — EVENT SPACE ° z APPLICABLE CODES: CITY OF EDMON DS MUNICIPAL CODE 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL FIRE CODE o z ~ Co TERRACE H SIG4.3 w wo � o z LuI, 0z o Q N w Z. 75CD 2019 NATIONAL FIRE ALARM AND CD Q o= cor 1(_- SIGNALING CODE w Cn O� - Q n QU Cn Z U 0 z O A 14/2 FPLP of Q x B 16/2 FPLP o EX EXISTING LOCATION D DEMO DEVICE N NEW DEVICE FIR 022-0028 R RELOCATE STROBEGE RCLGEA HHT.L BE DEFINED IRECEIVEDI SIG4.4 DN 10 FT. CLGHT.OVERA20 FT. OTC G HT. H 75CD 15 cd = 20'x20' 30 cd = 20'x20' 75 cd = 20'x20' 30 cd = 30'x30' 75 cd = 30'x30' 95 cd = 30'x30' 13/16/22 ® 75 cd = 40'x40' 95 cd = 40'x40' 110 cd = 40'x40' 95 cd = 50'x50' 110 Cd = 50'x50' 115 cd = 50'x50' JERVICESDEVELOPMENT CITY OF EDMONDS DEPARTMEN MONITOR KITCHEN HOOD � SIG4 DN 4.7K 0 SLC•M:1 AIM ® z N L® LJ� o 0 DN N E SIG4.1 SIG4.2 "� ° ° U ° H H 15CD 15C D Q N �¢ s Q I.-o> �CaQ N W OC "xno _ L-L_ •U E o x i C) V SLC•S:5 — IS SLC•S.• I4 IS z LE C) _ N ■I KITCHEN yWORKAREA 5 0—®Tranalt P Parkiiq ElPharmacies m ATMa �.o eGrace Lutheran Ch h E 1 LID 0µlemeMa,ySchool v JA (J< UCD M m W LLJ .. s c,a aEdmonwdseFood Danko THE BO L OF ED DS � c..�x., ` l Holy \\ ROSdry Church r Ch Eam For the For,he Adsch^s s ketts oxna �' a z .wws Emerald HillsQ z di l3 Nodh � O :✓ O U w - -a. �„a,\ VIIIa RivarolaQ �, �,�Rorys of Etlmantls EAST BUILDING — UPPER LEVEL a O (on) E }� � I—J Q \ emm 5� w`"a : ma.w /� ©Sah and Iron S 'OY g `j0`J l�+J E (� < YL/ L •� enis > 4 l EdmoMs� Edo.. Sil Ferry Terminal z s�ls z\ s y Edmonds Main SL dmonds, WA 98020 \ . O }I O Iq wo.n•.s who.. o.y,o.% o,h— canons 0' 2' 4' 6' 12' 20' w.w.9 v M.xw a,..w z z �� N cf 'C u„I C CL Cu Harbor Squar Q y Q AthlHlc b Yost Pool SCALE: 1 /4"=1 �-011 a s ,a :k�. sA g has Q ��♦ U C o c F- m o ''J Walnut Street Coffee lost PerkTennis S w.wws WelnN st � d,Plckleliall Cauft Edmonds ehelNbeyer xoihn' Marsh z 1A Y/ U Lu L O L I www spwa n ea hPadc —� \'Com_-Pack d w xmiml ���N N • f £ r Leash aw T N l z.an nsw f Edmonds N ,ssw `-, O ` �' /O N ' O /�y�./'-'�� c J EE s ani omd� rma C nd Edwa s Polnt �130 CO O f LL �+ L 1 � Lu � i VICINITY � o w O Cn U) J SCALE: N.T.S. I