FIR2022-0033+Fire_Sprinkler_Equipment_Specification_Sheets+3.31.2022_9.23.08_AM+2772899
RECEIVED Mar 31 2022 CITY OF EDMONDS DEVELOPMENT SEA"'^�" DEPARTMEI` FI R2022-0033 NOR TNWES T FIRE SYSTEMS 2545 83,d Ave. ., Bldg D * Kent, WA 98032 Ph: 206.772.7502 * Fax; 206.772.7504 Www.nwfiresysterns.corn LIC # NORTHF59 8CR EQUIPMENT SUBMITTAL 558 (east bldg) Main St Commons East Edmonds, WA NWSF JOB NO. 05043C TABLE OF CONTENTS Section 1 - Pipe and Fittings Victaulic_Firelock Fittings 10.03 Wheatland MegaFlow Pipe Wheatland_Sch 10 & Sch 40 Pipe Star _Ductile Iron Threaded Fittings (Import) Vicaulic_741_Vic-Flange Adapter Section 2 - Hangers and Sway Bracing Anvil _146_All Thread Rod Tolco_980_Universal Sway Brace Attachment Sammy_Sidewinders Afcon_300_Hanger Ring Afcon_400_Riser Clamp Tolco_4L_In Line Sway Brace Tolco_1001_Fast Clamp Sway Brace Attachment Tolco Fig 25 Surge Restrainer Caddy Branchline Restraint Pipe Attachment Caddy Branchline Wood/Concrete Structural Attachment Section 3 - Valves and Accessories Tyco_RM-1 Riser Manifold AGF 2511A Test and Drain Section 4 - Alarms and Supervisory Devices Potter VSR-F Waterflow Switch Section 5 - Fire Sprinklers Tyco_DS-1_QR_ Dry Pendent, Up, Horz Sw K=5.6 Tyco_TY-FRB_QR_SSP,SSU,Rec Pend_K=2.8,5.6,8.0 Section 6 — Miscellaneous Victaulic - Head Cabinet All variations used All variations used 00-002 Table Of Contents.xls Page 1 of 1 3/31/2022 SECTION 1 PIPE AND FITTINGS Victaulic° FireLockT" Fittings 1.0 PRODUCT DESCRIPTION Available Sizes • 11/a — 87DN32 — DN200 ✓ctaulic® 10.03 Maximum Working Pressure • Pressure ratings for Victaulic FireLockTM Fittings conform to the ratings of Victaulic Fire Lock EZTM Style 009N couplings (refer to publication 10.64 for more information). Application • FireLockTM fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. • Connects pipe, provides change in direction and adapts sizes or components Pipe Materials • Carbon steel 2.0 CERTIFICATION/LISTINGS D@LS F LPCB LISTED VdS C E EN 10311 Regulation (EU) No. 305/2011 3.0 SPECIFICATIONS — MATERIAL Fitting: Ductile iron conforming to ASTM A536, Grade 65-45-12. Fitting Coating: ❑ Orange enamel. ❑ Red enamel in Europe, Middle East, Africa, and India. ❑ Optional: Hot dipped galvanized. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Submitted By Date U442111ir rnm Spec Section Paragraph Approved Date 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. 1 ✓ctaulic° victaulic.com 4.0 DIMENSIONS �CtoE toE� p Cjto 0 0 to E]to J'F olo E No. 001 No. 003 No. 002 No. 006 No. 001 No. 003 No. 002 No. 006 90' Elbow 45° Elbow Straight Tee Cap Actual Approximate Approximate Approximate Approximate Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each T Each inches inches inches lb inches lb inches lb inches lb DN mm mm kg mm kg mm kg mm kg 11/4 1.660 - - - - - - 0.82 0.3 DN32 42.4 1.900 - - - - - - - - - 21 0.1 0.82 0.4 1 1/2 - - - DN40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 DN50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 3.30 2.25 2.4 3.00 3.8 DN65 76.1 76 1.5 57 1.1 76 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 DN80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 DN100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 8.2 4.88 15.4 DN125 139.7 124 5.6 82.6 3.7 124 6.9 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 DN150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 140 7.9 89 5.2 140 9.9 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 DN200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8.515 6.81 23.1 - - 6.94 33.6 - - 216.3 173 10.5 - - 176 15.2 - - 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 2 ✓ctaulic® victaulic.com 5.0 PERFORMANCE Flow Data Size Frictional Resistance Equivalent of Straight Pipe' No. 002 Actual Elbows Straight Tee No.001 No.003 Nominal Outside Size Diameter 90° Elbow 45° Elbow Branch Run inches inches feet feet feet feet DN mm meters meters meters meters 1 '/4 1.660 - - DN32 42.4 - - - 1 '/2 1.900 - - - DN40 48.3 - - - 2 2.375 3.5 1.8 8.5 3.5 DN50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 73.0 1.3 0.7 3.3 1.3 3.000 4.5 2.3 11.0 4.5 DN65 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 DN80 88.9 1.5 0.8 4.0 1.5 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 DN100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 141.3 2.6 1.3 6.4 2.6 5.500 8.3 4.1 20.6 8.3 DN125 139.7 2.5 1.3 6.3 2.5 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 DN 150 168.3 3.0 1.5 7.6 3.0 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 DN200 1 219.1 4.0 1.5 10.1 4.0 8.515 13.0 - 33.0 13.0 216.3 4.0 - 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com ✓ctaulic® victaulic.com 6.0 NOTIFICATIONS General Notes NOTE: When assembling Fire Lock EZTM couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For Fire Lock EZTM Style 009N/009H couplings, use FireLockTm No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H/009N couplings. 7.0 REFERENCE MATERIALS 10.64: Victaulic@ FireLockTm Rigid Coupling Style 009N 10.02: Victaulic@ Firel-ockTm Rigid Coupling Style 005H with Vic-PIusTm Gasket System 29.01: Victaulic® Terms and Conditions of Sale User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end -use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be made to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer. of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in PDF format on our website at www.victaulic.com. No statement contained herein concerning a possible or suggested use of any material, Warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victaulic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. or patent applications for articles and/or methods of use in the United States and/or other countries. 10.03 1539 Rev N Updated 09/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 4 ✓ctaill ZJ1111110 • FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube's Mega -Flow steel fire sprinkler pipe is FM Approved for roll -grooved, plain -end and welded joints for wet systems; and UL' and C-UL Listed and FM Approved for use with roll - grooved, swage groove, plain -end couplings and welded joints for wet, dry preaction and deluge systems. Mega -Thread is FM Approved for use in wet systems and is UL and C-UL Listed and FM Approved for wet, dry and preaction sprinkler systems. Approvals and Specifications Both products meet or exceed these standards: • ASTM A795, Type E, Grade A • NFPA® 13 and NFPA 14 • Mega -Thread is approved for standard hanger spacing Manufacturing Protocols Mega -Flow and Mega -Thread are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings Mega -Flow, like all Wheatland black steel fire sprinkler pipe, receives a proprietary mill coating to ensure a clean, corrosion -resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Mega -Thread is hot -dip galvanized to meet FM requirements for dry systems. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: ENGINEER: LOCATIONS: ❑ MEGA -FLOW -BLACK 1 Council Avenue, P.O. Box 608 Wheatland, PA 16161 P 800.257.8182 F 724.346.7260 MEGA -FLOW SPECIFICATIONS NOM NIPS OD NOM ID UL CRR* MEGA -FLOW Mega- Schedule Schedule Mega- Schedule Nominal Pcs./Lift Flow 10 40 Flow 40 wt./ft. 11/4 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 11/2 1.900 1.740 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 21/2 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19 4 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 0.75 1.00 8.000 10 " Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category V/ZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). MEGA -THREAD SPECIFICATIONS NOM NPS OD NOM ID UL CRR* MEGA -THREAD Mega- Schedule Mega- Schedule L.W.T. Nominal Pcs./Lift Thread 40 Thread 40 Pipe wt./ft. 1 1.315 1.079 1.049 1.00 1.00 0.61 1.462 70 11/4 1.660 1.416 1.380 1.00 1.00 0.39 1.989 51 11/1 1.900 1.650 1.610 1.00 1.00 0.31 2.370 44 2 2.375 2.117 2.067 1.00 1.00 0.25 3.094 30 " Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category V/ZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). UL C UL F M APPROVED CONTRACTOR: SPECIFICATION REFERENCE: COMMENTS: DATE: SYSTEM TYPE: ❑ MEGA -THREAD -HOT -DIP GALVANIZED WFS-052920 info@wheatland.com wheatland.com Follow us on Twitter: @WheatlandTube Wheatland Tube )Rtt��� A DIVISION OF ZEKELMAN INDUSTRIES FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube's Schedule 10 steel fire sprinkler pipe is FM Approved and UL" and C-UL Listed. Wheatland Tube is the only manufacturer with FM Approval on 10 NPS Schedule 10 steel fire sprinkler pipe. Approvals and Specifications Schedule 10 meets or exceeds the following standards: • ASTM A135, Type E, Grade A (Schedule 10, 1-10 NPS) • NFPAa 13 and NFPA 14 Manufacturing Protocols Schedule 10 is subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. PROJECT: ENGINEER: LOCATIONS: ❑ BLACK CONTRACTOR: Finishes and Coatings Schedule 10 can be ordered in black or hot -dip galvanized to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A53 or A795. Schedule 10 receives a proprietary mill coating to ensure a clean, corrosion -resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Every black steel Schedule 10 pipe also receives our MIC SHIELDT" antimicrobial coating to limit corrosion from microbes on the interior of the pipe. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. SPECIFICATION REFERENCE: COMMENTS: ❑ HOT -DIP GALVANIZED DATE: SYSTEM TYPE: lit 1 Council Avenue, P.O. Box 608 Wheatland, PA 16161 P 800.257.8182 F 724.346.7260 info@wheatland.com wheatland.com Follow us on Twitter: @WheatlandTube Wheatland Tube A DIVISION OF ZEKELMAN INDUSTRIES W W t 4-hL- -= SCHEDULE 10 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NIPS NOMINAL OD NOMINAL ID NOMINAL WALL WT./FT. H2O FILLED PCS./LIFT 21' 24' 25' UL in �m in. mrn�_ lbs. lbs. lbs. lbs. CRR• IL 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 1 % 1.660 42.2 1.442 36.6 0.109 2.77 1.807 2.514 61 2315 2645 2756 7.3 11/2 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 2 2.375 60.3 2.157 54.8 0.109 2.77 2.640 4.222 37 2051 2344 2442 4.7 21/2 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 88.9 3.260 82.8 0.120 3.05 4.336 7.949 19 1730 1977 2060 2.6 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 8 8.625 219.1 8.249 209.5 0.188 4.78 16.960 40.086 7 2493 2849 2968 1.7 10** 10.750 273.0 10.374 263.5 0.188 4.78 21.230 57.803 2 892 1019 1062 - * Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZV. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). 10 NPS Schedule 10 is FM Approved but not UL Listed. UL C UL F M APPROVED 1 Council Avenue, P.O. Box 608 info@wheatland.com WFS-072921 - Wheatland, PA 16161 wheatland.com Wheatland Tube P 800.257.8182 Follow us on Twitter: )RZj F 724.346.7260 @WheatlandTube A DIVISION OF ZEKELMAN INDUSTRIES FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube's Schedule 10 steel fire sprinkler pipe is FM Approved and UL" and C-UL Listed. Wheatland Tube is the only manufacturer with FM Approval on 10 NPS Schedule 10 steel fire sprinkler pipe. Approvals and Specifications Schedule 10 meets or exceeds the following standards: • ASTM A135, Type E, Grade A (Schedule 10, 1-10 NPS) • NFPAa 13 and NFPA 14 Manufacturing Protocols Schedule 10 is subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. PROJECT: ENGINEER: LOCATIONS: ❑ BLACK CONTRACTOR: Finishes and Coatings Schedule 10 can be ordered in black or hot -dip galvanized to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A53 or A795. Schedule 10 receives a proprietary mill coating to ensure a clean, corrosion -resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Every black steel Schedule 10 pipe also receives our MIC SHIELDT" antimicrobial coating to limit corrosion from microbes on the interior of the pipe. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. SPECIFICATION REFERENCE: COMMENTS: ❑ HOT -DIP GALVANIZED DATE: SYSTEM TYPE: lit 1 Council Avenue, P.O. Box 608 Wheatland, PA 16161 P 800.257.8182 F 724.346.7260 info@wheatland.com wheatland.com Follow us on Twitter: @WheatlandTube Wheatland Tube A DIVISION OF ZEKELMAN INDUSTRIES W W t 4-hL- -= SCHEDULE 10 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NIPS NOMINAL OD NOMINAL ID NOMINAL WALL WT./FT. H2O FILLED PCS./LIFT 21' 24' 25' UL in �m in. mrn�_ lbs. lbs. lbs. lbs. CRR• IL 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 1 % 1.660 42.2 1.442 36.6 0.109 2.77 1.807 2.514 61 2315 2645 2756 7.3 11/2 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 2 2.375 60.3 2.157 54.8 0.109 2.77 2.640 4.222 37 2051 2344 2442 4.7 21/2 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 88.9 3.260 82.8 0.120 3.05 4.336 7.949 19 1730 1977 2060 2.6 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 5.563 141.3 5.295 134.5 0.134 3.40 7.780 17.309 13 2124 2427 2529 1.5 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 8 8.625 219.1 8.249 209.5 0.188 4.78 16.960 40.086 7 2493 2849 2968 1.7 10** 10.750 273.0 10.374 263.5 0.188 4.78 21.230 57.803 2 892 1019 1062 - * Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZV. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). 10 NPS Schedule 10 is FM Approved but not UL Listed. UL C UL F M APPROVED 1 Council Avenue, P.O. Box 608 info@wheatland.com WFS-072921 - Wheatland, PA 16161 wheatland.com Wheatland Tube P 800.257.8182 Follow us on Twitter: )RZj F 724.346.7260 @WheatlandTube A DIVISION OF ZEKELMAN INDUSTRIES Vie -ange® Adapters STYLES 741 AND 743 Style 741 Style 741 Vic -Flange® adapter is designed for directly incorporating flanged components with ANSI CL. 125 or CL. 150/PN10 and PN16 or Australian Standard Table "E" bolt hole patterns into a grooved pipe system. Sizes 2 — 12750 — 300mm are hinged for easy handling with integral end tabs which facilitate assembly. Sizes 14 — 247350 — 600mm are cast in four (4) identical segments which are interconnected as assembly is completed. The design incorporates small teeth inside the key shoulder I.D. to prevent rotation (excluding 159mm size). These teeth should be removed when Vic -Flange adapter is utilized with a Victaulic Series 700 grooved end butterfly valve, Schedule 5 pipe or plastic pipe. Vic -Flange adapters may only be used on Vic-3000 butterfly valves on one side in 2 — 8750 — 200 mm sizes. They are not recommended for 10 and 127250 and 300 mm sizes. Vic -Flange adapter Style 741 is not recommended for use with Victaulic Series 709 butterfly valves (contact Victaulic for recommendations). They may only be used on one side of Victaulic Series 700 butterfly valve, sizes 2 — 4750 — 100mm fitted with standard or lever -lock handles. Vic -Flange adapter must be assembled so it does not interfere with handle operation. Style 743 Vic -Flange Style 743 flange -to -groove adapter permits direct connection of ANSI Class 300 flanged components into a grooved system. The two-piece, hinged housing engages into the pipe groove and bolts directly to any standard flanged component. The conventional bolt hole pattern allows for easy, fast assembly. Style 743 rotates 360' for proper alignment of bolt holes before tightening. Vic -Flange gaskets utilize the Victaulic pressure -responsive design, sealing on the pipe end and directly to the opposing flange face. No standard flange gasket is required. UL FM U ES SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 741 2 - 12" SIZES/50-300 MM A ply Often STYLE 741 14 - 24" SIZES/350-600 MM STYLE 743 Exaggerated for clarity Style 743 is designed to mate with raised -face flanges, but can be used with flat -face Exaggerated for clarity flanges by removing the raised projections on the outside face of the flange. VIC-FLANGE NOTES Because of the outside flange dimension, Vic -Flange should not be used within 90' of one another on a standard fitting. When wafer or lug -type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. Vic -Flange adapters should not be used as anchor points for tie -rods across non -restrained joints. Mating rubber faced flanges, valves, etc., requires the use of a Vic -Flange washer. Vic -Flange gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Location Date Approved www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_J Para ✓ctauhc 06.06_1 CARBON STEEL PIPE — GROOVED COUPLINGS 06.06 Vic-Flancre® Adapters STYLES 741 AND 743 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Black enamel. • Optional: Hot dipped galvanized and others. Coupling Gasket: (specify choice#) • Grade "E" EPDM EPDM (Green color code). Temperature range —30oF to +230°F/-34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil -free air and many chemical services. UL classified in accordance with ANSI/ NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade "T" nitrile Nitrile (Orange color code). Temperature range —20oF to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140°F/+60°C and water over +150°F +66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. f Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Draw Bolts: 14 — 247350 — 600 mm only: Heat -treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X, ICt_au I —id 06.06_2 REV_J CARBON STEEL PIPE - GROOVED COUPLINGS 06.06 Vie range® Adapters STYLES 741 AND 743 DIMENSIONS STYLE 741 Sizes 2 - 12750 - 300 mm ANSI Class 125 and 150 Flanges OutsideNominal Size D . Inches I mm mm 2 2.375 kPa 300 N Required 1,330 4 Inches 5 3 /a x 2 /a Maximum Minim u m 2.38 3.41 W X Z 6.75 6.00 4.75 0.75 3.1 50 60.3 2065 5920 60 87 172 152 1 121 19 7.87 7.00 5.50 0.88 1.4 4.8 2Y2 2.875 300 1,950 4 5/sx3 2.88 3.91 65 73.0 F4.500 2065 8680 5/s x 3 73 3.50 99 4.53 200 178 140 22 8.29 7.50 6.00 0.94 2.1 5.3 3 3.500 300 2,885 1 4 80 88.9 2065 12840 4,770 8 89 115 211 191 152 24 2.4 7.4 4 300 1/8 x 3 4.50 5.53 9.87 9.00 7.50 0.94 100 114.3 2065 21225 7,290 8 114 141 251 229 191 24 3.4 8.6 5 5.563 300 3/4 x 3'/2 5.56 6.71 10.90 10.00 8.50 1.00 125 141.3 2065 32440 10,350 141 171 277 254 216 25 3.9 9.9 6 6.625 300 6.63 7.78 11.90 11.00 9.50 1.00 150 168.3 2065 46060 8 3/a x 3 1 168 198 302 279 241 25 4.5 6.500 300 9,960 6.50 7.66 11.92 11.00 9.45 1.00 10.0 65.1 mm 165.1 2065 44320 8 3/4 x 3 1/2165 195 303 279 240 25 4.5 8 8.625 300 17,500 8 3/4 x 3'/2 8.63 9.94 14.50 13.50 11.75 1.13 16.6 200 219.1 2065 77875 219 252 368 1 343 1 298 29 7.5 10 10.750 300 27,215 12 /s x 4 10.75 12.31 17.24 16.00 14.25 1.19 24.2 250 273.0 2065 121110 273 313 438 406 362 30 11.0 12.750 300 38,285 12 /s x 4 12 12.75 14.31 20.25 19.00 17.00 1.25 46.8 300 323.9 2065 170270 324 364 514 483 432 32 21.2 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. t Total bolts required to be supplied by installer, may be ordered from Victaulic. IMPORTANT NOTES: Style 741 Vic -Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges. O 7� Vic Mating Flange Flange X Y W O A B Shaded area of mating face must Proper Gasket Positioning Max. Min. be free from gouges, undulations Exaggerated for Clarity or deformities of any type for effective sealing. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV J ✓ct_au I -id 06.06_3 CARBON STEEL PIPE — GROOVED COUPLINGS 06.06 Vic-Flancye® Adapters STYLES 741 AND 743 DIMENSIONS STYLE 741 Sizes 50 — 300 mm/ 2 — 12" PN10 and PN16 Flanges * Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1'/2 times the figures shown. # PN16 dimensions (mm/inches): W = 360/14.17, X = 340/13.39; Y = 295/11.61; Z = 30/1.18. § PN16 dimensions (mm/inches): W = 438/17.24; X = 406/15.98; Y = 362/14.00; Z = 30/1.18. t PN 16 dimensions (mm/inches): W = 478/18.82; X = 444/18.11; Y = 410/16.14, Z = 32/1.26. t Total bolts required, to be supplied by installer. Bolt sizes for conventional flange -to -flange connection. Longer bolts required when flange utilized with wafer -type valves. IMPORTANT NOTES: Style 741 Vic -Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may only be used on one side of the valve. Contact Victaulic for information on AS2129 - Table E; ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10k) flanges. Shaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing. Vic Mating Flange 4FIange A B Proper Gasket Positioning Max. Min. Exaggerated for Clarity www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 06.06_4 ✓ctaulid REV_J CARBON STEEL PIPE - GROOVED COUPLINGS 06.06 Vie range® Adapters STYLES 741 AND 743 DIMENSIONS STYLE 741 Sizes 2 - 8750 - 200 mm Australian Standard Table "E" Flanges Size Nominal Actual Outside Max. Work Pressure Max. End Load No. Bolts I Bolt Size I Sealing mm/Inches Surface Dimensions - mm/Inches Approx. Wgt. Eac Size I nche s 50 Diameter I nches 60.3 psi 1400 Lbs. 4005 Required 4 Inches 5/e x 2 3/a xim 60 nim 84 165 152 114 19 Lbs. 1.9 2.375 203 900 2.38 3.31 6A8 6.00 4.48 0.75 4.1 -2 80 88.9 1400 8700 4 s /s x 3 89 113 200 191 146 24 2A _3 3.500 203 1955 3.50 4.44 7.87 7.50 5.75 0.94 5.4 114.3 1400 5 /e x 3 114 131 25 2229 191 100 14374 8 24 3.3 4 4.500 203 3230 4.50 5.16 9.87 9.00 7.50 0.94 7.2 65.1 mm 165.1 1400 14374 8 1/4 x 3'/z 165 192 303 279 235 25 5.0 6.500 203 6735 6.50 7.56 11.92 11.00 9.25 1.00 11.0 150 168.3 1400 31150 8 3/4 x 3'/z 168 192 286 279 235 25 4.5 6 6.625 203 7000 6.63 7.56 11.25 11.00 9.25 1.00 9.9 200 219.1 1400 52777 8 3 1 /° x 3 /z 219 247 368 343 298 29 5.7 8 8.625 203 11860 8.63 9.72 14.50 13.50 11.75 1.12 12.5 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. t Total bolts required to be supplied by installer, may be ordered from Victaulic. IMPORTANT NOTES: Style 741 Vic -Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges. Shaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing. Vic Mating Flange Flange A B Proper Gasket Positioning Max. Min. Exaggerated for Clarity www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV J ✓ct_au I -id 06.06_5 CARBON STEEL PIPE — GROOVED COUPLINGS 06.06 Vic-Flancye® Adapters STYLES 741 AND 743 DIMENSIONS STYLE 741 Sizes 14 — 247350 — 600 mm# ANSI Class 125 and 150 Flanges * Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. t Total bolts required to be supplied by installer, may be ordered from Victaulic. Bolt sizes for conventional flange -to -flange connection. Longer bolts required when Vic -Flange utilized with wafer -type valves. § Draw bolts supplied with 14 — 247350 — 600 mm Vic -Flange adapters. # For cut groove systems only. For 14 — 247350 — 600 mm roll groove systems, AGS (Advanced Groove System) products are used. Style 741 is not compatible with the AGS system. z ° A VO� X o B o Y T W O�Qo�OQo� Shaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing. Me- Mating Flange Flange A B Proper Gasket Positioning Max. Min. Exaggerated for Clarity www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 06.06_6 ✓ctaulid REV_J CARBON STEEL PIPE - GROOVED COUPLINGS 06.06 Vie range® Adapters STYLES 741 AND 743 DIMENSIONS STYLE 743 Grooved pipe adapter to ANSI Class 300 flanges Size Nominal OutsideMax Actual ' Work Pressure Max. End Load No. Bolts t Bolt/Nut Size t Sealing Inches/mrn Surface Dimensions - Inches/mrn Approx. Wgt. Each Size Inches 2 .. I 2.375 720 3,190 8 s /a x 3 2.38 1 3.41 7.70 6.50 5.00 0.93 4.8 50 60.3 4960 14200 4,670 8 3/a x 3'/a 60 2.88 87 3.91 196 8.61 165 7.50 127 5.88 24 1.06 2.2 7.4 2 Yz 2.875 720 65 73.0 4960 20780 6,925 8 73 99 219 191 149 27 3.4 9.1 3 3.500 720 /a x 3 /z 3.50 4.53 9.48 8.25 6.63 1.18 80 88.9 4960 30815 11,445 8 89 115 241 210 168 30 4.1 4 4.500 720 3 /a x 3 /a 4.50 5.53 11.35 10.00 7.87 1.31 15.3 100 114.3 4960 50930 17,500 8 114 141 288 254 200 33 6.9 5 5.563 720 3 /a x 4 5.56 6.72 12.31 11.00 9.25 1.43 17.7 125 141.3 4960 77875 24,805 12 141 171 313 279 235 36 8.0 6 6.625 720 1 3 /a x 4 /z 6.63 7.78 13.77 12.50 10.63 1.50 23.4 150 168.3 4960 110380 168 198 350 318 270 38 10.6 8 8.625 720 42,045 12 3 7/8 x 4 /a 8.63 9.94 16.68 15.00 13.00 1.68 34.3 200 219.1 4960 187100 219 252 424 381 330 43 15.6 10 10.750 720 65,315 16 1 x 5 1/a 10.75 12.31 19.25 17.50 15.25 1.93 48.3 250 273.0 4960 290650 273 313 489 445 387 49 21.9 12 12.750 720 91,880 16 3 1 /s x 5 /a 12.75 14.31 22.25 20.50 17.75 2.06 70.5 300 323.9 4960 408870 324 363 565 521 451 52 32.0 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown. Style 743 Vic -Flange must be ordered as a factory assembly when connected to a Victaulic fitting or valve. Contact Victaulic for details. t Total bolts required to be supplied by installer, may be ordered from Victaulic. Remove to mate-> Z IF to flat -faced �i YW Shaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing. Vic- Mating Flange Flange A B Proper Gasket Positioning Max. Min. Exaggerated for Clarity www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV J ✓ct_au I -id 06.06_7 CARBON STEEL PIPE — GROOVED COUPLINGS 06.06 Vic -Flange® Adapters STYLES 741 AND 743 VIC-FLANGE ADAPTER NOTES 1. The Style 741 (2 — 12'750 — 300 mm) design incorporates small teeth inside the key shoulder I.D. to prevent rotation. These teeth should be removed when Vic -Flange adapter is utilized with a Victaulic Series 700 grooved end butterfly valve, Schedule 5 pipe or plastic pipe. Vic -Flange adapter Style 741 may only be used on one side of Victaulic Series 700 butterfly valve, sizes 2 — 4750 — 100 mm fitted with standard or latch -lock handles. 2. Vic -Flange adapter must be assembled so it does not interfere with handle operation. Because of the outside flange dimension, Vic -Flange adapter should not be used within 90' of one another on a standard fitting. When wafer or lug -type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance. 3. Vic -Flange adapters should not be used as anchor points for tie -rods across nonrestrained joints. Mating rubber faced flanges, valves, etc. requires the use of a Vic -Flange washer. 4. Area A-B noted in the above drawing must be free from gouges, undulations or deformities of any type for effective sealing. 5. Vic -Flange adapter gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange. 6. Vic -Flange hinge points must be oriented approximately 90' to each other when mated 7. Flange Washers: Vic -Flange adapters require a smooth hard surface at the mating flange face for effective sealing. Some applications for which the Vic -Flange adapter is otherwise well suited do not provide an adequate mating surface. In such cases, it is recommended that a metal (Type F phenolic for Style 641 with copper systems) Flange Washer be inserted between the Vic -Flange adapter and the mating flange to provide the necessary sealing surface. Typical applications where a Flange Washer should be used are: A. When mating to a serrated flange: a flange gasket should be used adjacent to the serrated flange and then the Flange Washer is inserted between the Vic -Flange adapter and the flange gas ket. B. When mating to a wafer valve: where typical valves are rubber lined and partially rubber faced (smooth or not), the Flange Washer is placed between the valve and the Vic -Flange adapter. C. When mating a rubber faced flange: the Flange Washer is placed between the Vic -flanges and the rubber faced flange. D. When mating AWWA cast flanges to IPS flanges: the Flange Washer or Transition Ring is placed between two Vic -Flange adapters with the hinge points oriented 90° to each other. If one flange is not a Vic -Flange adapter (e.g., flanged valve), then a flange gasket must be placed adjacent to that flange and the Flange Washer inserted between the flange gasket and the Vic -Flange adapter. Transition rings rather than Flange Washers must be used when mating Style 741 to Style 341 Flange Adapters in sizes 14 — 247350 — 600 mm. E. When mating to components (valves, strainers, etc.) where the component flange face has an insert: follow the same arrangement as in Application 1. When ordering Flange Washers, always specify product style (Style 741, 743, 341, 641, 994) and size to assure proper Flange Washer is supplied. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ICt9UI1C° 06.06_8 REV_J Vice -Flange® Adapters STYLES 741 AND 743 GENERAL NOTES WARRANTY Style 741 and 743 Vic -Flange adapters provide rigid joints when used on pipe with standard roll or cut groove dimensions and consequently allow no linear or angular movement at the joint. Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. For complete contact information, visit www.victaulic.com 06.06 1534 REV J UPDATED 7/2009 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X. _au lic 06.06 SECTION 2 HANGERS AND SWAY BRACING HANGER RODS Z /ANVIL Fig. 146 Size Range:'/4 through 11/2" Stocked in six, ten, and twelve foot lengths. Other even foot lengths can be furnished to order. Material: Carbon steel or Stainless Steel Gr 304 Threads: National Coarse (USS), rod threaded complete length. Finish: ❑ Plain or❑ zinc Plated (Hot -Dip Galvanized optional) Maximum Temperature: 650' F. Ordering: Specify rod diameter and length, figure number, name and finish. Note: The acceptability of galvanized coatings at temperatures above 450°F is at the discretion of the end user. 1,1111111111111111111111111�11111111�111111111111�11111111111111�11�1111111111111111111111111111�11111111111111111111�11111111�111111�111111111111�111111�111111�111111�11�11�11�11�111111�11�11�111111�111111111111111111111111�111111111111 Continuous Threaded Rod FIG.146: LOADS (LBS) • WEIGHTS (LBS) • DIMENSIONS (IN) Rod Size A Threads per Inch Max Load 650° F Weight per Ft. 'A 20 240 0.12 % 16 730 0.30 '/2 13 1,350 0.53 % 11 2,160 0.84 3/a 10 3,230 1.20 7/8 9 4,480 1.70 1 8 5,900 2.30 1'/a 7 9,500 3.60 1'/2 6 13,800 5.10 Note: Other rod sizes available upon request. Class 2 fit is available upon request. PROJECT1 1APPROVAL Project: []Approved Address: []Approved as noted Contractor: ❑ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.15 il #14 SW Red Nut Driver Part # 8114910 Y #14 Black Nut Driver - Part # 8113910 i . #14 SH Orange Nut Driver Part # 8273910 WAMRMIVJ�M,J�Y�� Not less than 2" nominal width (1-1/2") up to 3-1/2" pipe; not less than 3" (2-1/2") nominal width 4" & 5' pipe 7FloorJoTist Minimum 2-1/2" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams. Consult t SWG :r • No pre -drilling required. • Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. • Saves time from traditional methods. • Reduces installation costs. • Assembled in the U.S.A. View our installation videos! O Y4uh he JKL 3/8" 8020957 SWG 10 1/4 x 1" 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 3/8" 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 3/8"* 8023925 SWG 30 1/4 x 3" 1884 (Fir) 25 125 I wMAWr A&Unmkr aks"r fAMEN 'm V44 mews wrawweer 3/8" 8139957 SH-GST 20 1/4 x 2" 1257 (Fir) 1903 Dim. Lumber 3/8"* 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical Dim. Lumber May require pre -drilling; consult joist manufacturer. ** Will not swivel until installed with black nut driver. • Eliminates distortion of threaded rod. • Accommodates up to 3%" x 12 pitch roof. • Allows 17* deflection from vertical. • Saves time from traditional methods. • Reduces installation costs. • Assembled in the U.S.A. 1050 1475 25 125 1500 25 125 850 @ 45° 00004 '0000009/Z�Fg §Z0 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 1 thru 4 inch pipe LISTED FOR STEEL/CPVC RING HANGER 1/2 & 3/4 inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - 4iusno ' 203-EX 2551 1 "- 8" <S> Approval guide - 1"- 8" OSHPD OPA-0601 See Website. NFPA 13 PIPE ROD 1 WT. 5 WT.+250 UL TEST LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469.75 750 1 1/2 3/8 54.15 520.75 750 2 3/8 76.95 1 634.75 750 21/2 318 118.35 841.75 850 3 3/8 162.30 1061.50 1050 3/8 246.00 1480.00 1500 112 349.45 1996.75 2000 E64 112 476.35 2631.75 2650 112 711.00 3805.00 4050 CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650T. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES- * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11 /09 00004 '0000009/Z�Fg §Z0 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 400 RISER CLAMP IRON PIPE B B SIZE - 1/2 thru 20 inch pipe. MATERIAL - Carbon Steel. FINISH - Plain, E.G., H.D.G. and S.S. LISTING/APPROVAL - �Q,S EX 2551 11/2"- 8" pipe. OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, type 8, 3/4 thru 20 inch, and Manufacturers Standardization Society SP-69, type 8. FUNCTION - Used for supporting vertical piping. ORDERING - Part #, pipe size and finish. PIPE SIZE A B C STOCK SIZE MAX. REC. LOAD LBS. 1 1/2" 10 3/8" 3/8" 1 1/2" 3/16"x1 1/4" 255 2" 10 3/4" 3/8" 2" 3/16"x1 1/4" 255 2 1/2" 11" 3/8" 2 1/8" 1/4"x1 1/4" 390 3" 12" 3/8" 3 1/4"x1 1/4" 530 3 1/2" 13" 1/2" 3 5/16" 1 /4"x1 1/4" 670 4" 13 1/2" 1/2" 3 3/8" 1/4"x1 1/4" 810 5" 14 1/2" 1/2" 4" 1/4"x1 1/2" 1160 6" 15 1 /8" 1 1/2" 4 1/2" 1 /4"x2" 1570 8" 181/2" 1 5/8" 513/16" 3/8x2" 2500 NOTE: MAXIMUM TEMPERATURE: 650°F 1/08 Fig. 980 - Universal Swivel Sway Brace Attachment Size Range — One size fits bracing pipe 1 " thru 2", TOLCO 12 gauge channel, and all structural steel up to 1/4" thick. Material — Carbon Steel Function — Multi -functional attachment to structure or braced pipe fitting. Features — This product's design incorporates a concen- tric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation — The Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or 4B to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install — Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until set bolt head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Note — The Fig. 980 Swivel Attachment and the Fig. 1001, Fig. 1000, Fig. 2002, Fig. 4A, Fig. 4B or Fig. 4L Pipe Clamp make up a sway brace system of UL Listed attachments and bracing materials which satisfies the require- ments of Underwriters' Laboratories and the National Fire Protection Association (NFPA) Finish — Plain Note — Available in Electro-Galvanized finish. Order By — Figure number and finish. Pat. #6,273,372, Pat. #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat. #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Lateral Brace Dimensions • Weights Max. Design Max. Design Approx. A B H* Load Lbs. Load Lbs.** Wt./100 (cULus) (FM) 51/4 17/8 17/32 2765 2800 132 Available with hole sizes to accommodate up to 3/4" fastener. Consult factory. The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin 0, where 0 is the installation angle measured from the vertical. ed m TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO° brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Seismic Bracing Fig. 4L - Longitudinal In -Line Sway Brace Attachment Size Range: 21/2" (65mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance Approvals: Approved by Factory Mutual Engineering (FM), 21/2" (65mm) through 8" (200mm) pipe. For UL Listed information refer to page 50. Installation Instructions: Fig. 4L is the "braced pipe" attachment component of a longitudinal sway brace assembly. It is intended to be combined with the "bracing pipe" and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or FM guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage "bracing pipe" into jaw opening and tighten set bolt until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. Designed to meet or exceed requirements of FM IDS 2-8. 4-Way Riser Brace (plan view) Longitudinal Brace Sat Rnit R Rard-are 1—hidad Y u ■ M■ FM APPROVED Part No. Pipe Size in. (nun) A in. (nun) C in. (nun) D in. (mm) Bolt Size 30°-44° lbs. (M) Max. Rec. Load (FM) 450-590 600-740 lbs. (M) lbs. (M) 750-900 lbs. NN) Approx. Wt./100 lbs. (kg) 4L-21/2 21/2" (65) 67/16" (163.5) 21/2" (63.5) 23/4" (69.8) 1/2"-13 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 253 (114.7) 40 3" (80) 7" (177.8) 23/4" (69.8) 31/16" (77.8) 1/2"-13 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590 (7.07) 268 (121.5) 41.-4 4" (100) 81/2" (215.9) 33/8" (85.7) 311/16" (93.7) 1/2"-13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 348 (157.8) 4L-5 5" (125) 93/4" (247.6) 37/8" (98.4) 43/8" (111.1) 1/2"-13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 380 (172.3) 4L-6 6" (150) 111/2" (292.1) 5" (127.0) 51/8" (130.2) 1/2"-13 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 640 (290.3) 4L-8 8" (200) 131/4" (336.5) 55/8" (142.8) 55/8" (142.9) 1/2"-13 490 (2.18) 680 (3.02) 830 (3.69) 930 (4.13) 728 (330.2) FM Approved when used with 1 ", 11/4", 11/2" or 2" Sch. 40 brace pipe FM Approved design loads are based on ASD design method. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 51 — Une by UJ-N Seismic Bracing Fig. 4LA - In -Line Sway Brace Attachment Size Range: 1" (25mm) through 12'' (300mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: For FM Approval information refer to page 53. Installation Instructions: Fig. 4LA can be used as the system attachment component of a longitudinal or lateral brace assembly. It is intended to be combined with the "bracing member" and TOLCO transitional attachment and structural attachment to form a complete bracing assembly. For fire sprinkler applications NFPA 13 guidelines should be followed. To Install: Place the Fig. 4LA pipe clamp component over the pipe to be braced and tighten down the break -off nuts until the hex head portion breaks off to verify correct installation torque. Next engage brace member (pipe or strut) with jaw component and tighten break -off head bolt until the hex head breaks off to verify correct installation torque. Pivot jaw for correct angle and attach to structure using TOLCO brand transitional attachment and structural attachment. Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. Long B 4LA-5thru 4LA-12 ODTOL.C❑ Part No. Pipe Size in. (mm) A in. (mm) c in. (mm) in. D (mm) Bolt Size Max. Rec. Load Longitudinal & Lateral lbs. (M) Approx. Wt./100 lbs. (kg) 4LA-1 1" (25) 319/32" (91.2) 15/16" (33.5) 15/16" (33.5) 3/8"-16 1000 (4.45) 119 (54.0) 4LA-11/4 11/4" (32) 329/32" (99.3) 13/8" (35.3) 13/8" (35.3) 3/8"-16 1000 (4.45) 123 (55.8) 4LA-11/2 11/2" (40) 45/32" (105.7) 11/2" (38.5) 11/2" (38.5) 3/8"-16 1000 (4.45) 127 (57.6) 4LA-2 2" (50) 511/32" (135.6) 21/32" (51.9) 21/16" (51.9) 3/8"-16 1000 (4.45) 142 (64.4) 4LA-21/2 21/2" (65) 527/32" (148.7) 25/16" (58.5) 25/16" (58.5) 3/8"-16 1000 (4.45) 173 (78.5) 4LA-3 3" IN 61/2" (164.9) 25/8" (66.6) 25/8" (66.6) 3/8"-16 1000 (4.45) 187 (84.8) 4LA-31/2 31/2" (90) 7.407" (188.1) 27/8" (73.1) 27/8" (73.1) 3/8"-16 1000 (4.45) 198 (89.8) 4LA-4 4" (10o) 713/32" (190.8) 31/8" (79.5) 31/8" (79.5) 3/8"-16 1000 (4.45) 209 (94.8) 4LA-5 5" (125) 83/4" (222.3) 35/8" (92.1) 35/8" (92.1) 1/2"-13 1600 (7.12) 298 (135.2) 4LA-6 6" (150) 105/8" (269.9) 49/16" (115.9) 49/16" (115.9) 1/2"-13 1600 (7.12) 521 (236.3) 4LA-8 8" (200) 1213/16" (325.5) 59/16" (143.7) 521/32" (143.7) 1/2"-13 2015 (7.12) 629 (285.3) 4LA-10 10" (250) 161/2" (419.1) 71/4" (184.2) 71/4" (184.2) 1/2"-13 2765 (8.96) 1320 (598.7) 4LA-12 12" (300) 181/2" (469.9) 81/4" (209.6) 81/4" (209.6) 1/2"-13 -- -- 1496 (678.6) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified B-LI rle by E':T•IY 52 Fire Protection Solutions Seismic Bracing Fig. 4LA - In -Line Sway Brace Attachment Size Range: 1" (25mm) through 12" (300mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Approved by Factory Mutual Engineering (FM), 1" (25mm) through 12" (300mm) pipe. Installation Instructions: Fig. 4LA can be used as the system attachment component of a longitudinal or lateral brace assembly. It is intended to be combined with the "bracing member" and TOLCO transitional attachment and structural attachment to form a complete bracing assembly. For fire sprinkler applications NFPA 13 guidelines should be followed. To Install: Place the Fig. 4LA pipe clamp component over the pipe to be braced and tighten down the break -off nuts until the hex head portion breaks off to verify correct installation torque. Next engage brace member (pipe or strut) with jaw component and tighten break -off head bolt until the hex head breaks off to verify correct installation torque. Pivot jaw for correct angle and attach to structure using TOLCO brand transitional attachment and structural attachment. Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. Longitt Bra Lateral Brace 4T c 4LA-1 thru 4LA-4 4LA-5 thru 4LA-12 d)TOLCO FM APPROVED Part No. Pipe Size in. (mm) A in. (mm) c in. (mm) D in. (nun) Bolt Size 30*-44* lbs. NN) FM Max. Rec. Load Longitudinal & Lateral** 450-590 60*-74* lbs. (M) lbs. (M) 750-900 lbs. NN) Approx. Wt./100 lbs. (kg) 4LA-1 1" (25) 319/32" (91.2) 15/16" (33.5) 15/16" (33.5) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 119 (54.0) 4LA-11/4 11/4" (32) 329/32" (99.3) 13/8" (35.3) 13/8" (35.3) 3/8-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 123 (55.8) 4LA-11/2 11/2" (40) 45/32" (105.7) 11/2" (38.5) 11/2" (38.5) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 127 (57.6) 4LA-2 2" (50) 511/32" (135.6) 21/32" (51.9) 21/16" (51.9) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 142 (64.4) 4LA-21/2 21/2" (65) 527/32" (148.7) 25/16" (58.5) 25/16" (58.5) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 173 (78.5) 4LA-3 3" (80) 61/2" (164.9) 25/8" (66.6) 25/8" (66.6) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 187 (84.8) 4LA-31/2 31/2" (90) 7.407" (188.1) 27/8" (73.1) 27/8" (73.1) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 198 (89.8) 4LA-4 4" (100) 713/32" (190.8) 31/8" (79.5) 31/8" (79.5) 3/8"-16 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 209 (94.8) 4LA-5 T (125) 83/4" (222.3) 35/8" (92.1) 35/8" (92.1) 1/2"-13 680 (3.02) 970 (4.31) 1190 (5.29) 1320 (5.87) 298 (135.2) 4LA-6 6" (150) 105/8" (269.9) 49/16" (115.9) 49/16" (115.9) 1/2"-13 1620 (7.20) Note 1 Note 3 Note 5 521 (236.3) 4LA-8 8" (200) 1213/16" (325.5) 59/16" (143.7) 521/32" (143.7) 1/2"-13 1620 (7.20) Note 2 Note 4 Note 6 629 (285.3) 4LA-10 10" (250) 161/2" (419.1) 71/4" (184.2) 71/4" (184.2) 1/2"-13 1620 (7.20) Note 2 Note 4 Note 6 1320 (598.7) 4LA-12 12" (300) 181/2" (469.9) 81/4" (209.6) 81/4" (209.6) 1/2"-13 1620 (7.20) Note 2 Note 4 Note 6 1496 (678.6) ** Longitudinal and Lateral Loads are the same except where noted in chart. Note 1: Longitudinal Load 2260 lbs. (10.05kN) - Lateral Load 2300 lbs. (10.23kN) Note 2: Longitudinal Load 1660 lbs. (7.38kN) Lateral Load 2300 lbs. (10.23kN) Note 3: Longitudinal Load 2010 lbs. (8.94kN) - Lateral Load 2820 lbs. (12.54kN) Note 4: Longitudinal Load 1570 lbs. (6.98kN) Lateral Load 2820 lbs. (12.54kN) Note 5: Longitudinal Load 2220 lbs. (9.87kN) - Lateral Load 3140 lbs. (13.96kN) Note 6: Longitudinal Load 1740 lbs. (7.74kN) Lateral Load 3140 lbs. (13.96kN) Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified Fire Protection Solutions 53 B-Line by F:T+N Fig. 1001 - Sway Brace Attachment Size Range — Pipe size to be braced: 2'/2" thru 8" IPS.* Pipe size used for bracing: 1 " and 11/4" Schedule 40 IPS. Material — Carbon Steel Function — For bracing pipe against sway and seismic distur- bance. The pipe attachment component of a sway brace system: The Fig. 1001 is used in conjunction with a TOLCO 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a com- plete sway brace assembly. Features — Can be used to brace schedules 7 through 40 IPS. Field adjustable, making critical pre -engineering of bracing pipe length unnecessary. Unique design requires no threading of brac- ing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note — Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1 " pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals — Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish — Plain Note — Available in Electro-Galvanized and HDG finish. Order By — Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. Important Note — The Fig. 1001 is precision manufactured to perform its function as a critical component of a complete brac- ing assembly. To ensure performance, the UL Listing requires that the Fig. 1001 must be used only with other TOLCO bracing_ products. The Fig 1001 is not intended for use with the Fig. 907 4-Way Longitudinal Brace Attachment. Component of State of California OSHPD Approved Seismic Restraints System C UL US LISTED FM Maximum Design Load Sch. 7 - 1600 lbs. Sch. 10 & 40 w/1 " Brace Pipe - 2015 lbs. Sch. 10 & 40 w/11/4" Brace Pipe - 2765 lbs. FM Approved Design Loads' 21/2" - 2400 lbs. 3" - 4" - 2500 lbs. 5" - 8" - 1500 lbs. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX 951.737.0330 ■ CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer Size Range — One size fits 3/4" thru 2" pipe. Material — Pre -Galvanized Steel Function — Designed to be used in conjunction with TOLCOO Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficient- ly installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals — Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish — Pre -Galvanized Order By — Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 C @US LISTED OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 1 www.tolco.com i, Accepts 3/8" or 1/2" (M10 or M12) threaded rod i, Quick grip clamp simplifies measuring and cutting of threaded rod i, Eliminates need to cut threaded rod to exact dimensions i, Works with rough -cut threaded rod and eliminates pipe -side deburring f, Can be installed with threaded rod above or below the service pipe f, Shear -off head helps ensure correct torque and simplifies inspection Material: Steel Finish: Electrogalvanized C UL US F"" OSH PD APPROVED Part Number Pipe Size Outer Diameter OD Rod Size IRS Height H Length L Width W CSBBRP0100EG 1" 1.32" 3/6", 1/2" 6.67" 1.63" 0.88" CSBBRP0125EG 1 1/4" 1.66" 3/8", 1/2" 7.56" 1.97" 0.88" CSBBRP0150EG 1 1/2" 1.90" 3/8", 1/2" 8.20" 2.21" 0.88" CSBBRP0200EG 2" 2.38" 3/8", 1/2" 9.45" 2.69" 0.88" FM is a registered certification mark of FM Approvals LLC, LTD. UL, UR, cUL, cUR, cULus and cURus are registered certification marks of UL LLC. WARNING nVent products shall be installed and used only as indicated in nVent's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty. 16 2021 nVent All rights reserved nVent, nVent CADDY, nVent ERICO, nVent ERIFLEX and nVent LENTON are owned by nVent or its global affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without prior notice. n�ent CADDY FEATURES & BENEFITS Swivel barrel nut accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to wood or concrete where cracked concrete approval is not needed Catalog Number Material CSBBRS2EG Steel Catalog Number CSBBRS2EG Finish ElectrogaIvan ized Screw Diameter(Sc) 1 /4" Table 1 /2 Rod Width(W) Size(RS) 3/8", 1 /2" 1.060" Table 2/2 Screw Length(L) 1 3/4" Length(L) Height(H) 1.590" 1.110" Drill Bit Diameter 3/16" Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. North America +1.800.753.9221 Option 1 — Customer Care Option 2 — Technical Support Europe Netherlands: +31 800-0200135 France: +33 800 901 793 Europe Germany: 8001890272 Other Countries: +31 13 5835404 APAC Shanghai: + 86 21 2412 1618/19 Sydney: +61 2 9751 8500 SECTION 3 VALVES AND ACCESSORIES tqC00 Model RM-2 Riser Manifold General Description The TYCO Model RM-2 Riser Mani- fold features the necessary water - flow alarm, pressure gauge, alarm test orifice, drain, sight glass and check valve equipment in a single assembly for use in National Fire Protection Asso- ciation (NFPA) standard NFPA 13* com- pliant commercial sprinkler systems. The riser manifold is available in a 2 in. to 6 in. range of sizes, and pro- vides a cost effective and easy transi- tion arrangement to control valves and system piping. The riser manifold may be installed in either a horizontal or ver- tical orientation, for both single sprin- kler rises and floor control in high-rises. A TYCO Model TD-2 Test and Drain Valve installed on the riser manifold as shown in Figure 2 provides a simplified means for testing of waterflow alarm devices and draining for feed mains. The pressure relief valve, integrated in the TYCO Model TD-2 Test and Drain Valve, has an adjustable range of 100 psi (6,9 bar) to 310 psi (21,4 bar). Excess system pressure is exhausted internally through the TD-2 valve's drain outlet. For more information about the Model TD-2 Test and Drain Valve, refer to Technical Data Sheet TFP965. ' Although the Riser Manifold described in this techni- cal data sheet is intended for the NFPA 13 sprinkler systems, it may be used for NFPA 13D or 13R residen- tial sprinkler systems, where a test orifice of 2.8K or 4.2K is acceptable. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. NOTICE The TYCO Model RM-2 Riser Manifold described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Approvals UL and C-UL Listed FM Approved Components Listed by California State Fire Marshall Note: Any alteration to the assembly voids UL approval and the product warranty. Maximum Working Pressure 300 psi (20,7 bar) Friction Loss See Table A Available Sizes 2 in. (DN50) 2-1/2 in. (DN65) 3 in. (DN80) 4 in. (DN100) 6 in. (DN150) Test Orifice 2 to 3 in. (DN50 to DN80) Manifolds: 2.8K 4 to 6 in. (DN100 to DN150) Manifolds: 4.2K Worldwide I www.tyco-fire.com Contacts Page 1 of 6 SEPTEMBER 2021 TFP964 TFP964 Page 2 of 6 No Qty Part Description CH Part Number or Specification 2 (DN50) 2-1/2 (DN65) 3 (DN80) 6 (DN150) 59300GO25WS 59300GO25WS 5930OG03OWS 5930OG04OWS 5930OG06OWS 1 1 Model BFV-300 Butterfly Valve, G x G 2 Figure 716 Reducing Grooved Coupling 7162520ES - - - - 2 1 Figure 577 Rigid Grooved Coupling - 57725ACP 57730ACP 57740ACP 57760ACP 3 2 Figure 577 Rigid Grooved Coupling 57720ACP 57725ACP 57730ACP 57740ACP 57760ACP 4 1 Groove x Groove Nipple, Flow Switch 5940020 5940025 5940030 5940040 5940060 5 1 Waterflow Alarm Switch, Potter VSR 24110 24111 24112 24114 24116 6 1 Model CV-1 FIR Riser Check Valve 59590102ORM 595901025 595901030 595901040 595901060 7 1 Groove x Groove x Thread Tee, TD-2 5940021 5940026 5940031 5940041 5940061 8 1 Model TD-2 Test and Drain Valve 1-1/4" x 2.8K Orifice 598321 - 2" x 4.2K Orifice - 598322 9 1 Model RM-2 Identification Tag 5941020 5941025 5941030 5941040 5941060 10 1 Water Pressure Gauge, 300 psi/2000 kPa 923431005 923431005 923431005 923431005 923431005 11 1 1/4" Gauge Test Valve 460051003 460051003 460051003 460051003 460051003 12 1 Pipe Nipple, Galvanized ✓ 1/4" x 3" 1/4" x 3-1/2" 13 2 Pipe Plug, Galvanized ✓ 1/4" 14 1 1 1 Pipe Plug, Galvanized ✓ 1-1/4" 2" NOTES 1. CH = Common Hardware 2. Refer to Technical Data Sheet TFP950 for information on Model CV-1 FR Riser Check Valve replacement parts Nominal Valve Size, in. (DN) Nominal Dimensions, in. (mm) A B C D E F G H 2 (DN50) 1-1/4 NPT 23.5 (597) 2.6(66) 9.4(239) 8.4(213) 4.7(119) 5.1 (130) 2-1/2 (DN65) 24.8 (630) 3.5(89) 10.0 (254) 8.4(213) 5.7(145) 3 (DN80) 25.2 (640) 3.7(94) 10.2 (259) 8.6(218) 5.9(150) 4 (DN100) 2 NPT 28.2 (716) 4.6(117) 11.1 (282) 9.6(244) 5.0 (127) 6.6(168) 6 (DN150) 31.3 (795) 5.9(150) 12.0 (305) 11.4 (290) 7.5(191) D E - TEST AND DRAIN VALVE - SYSTEM WATER PRESSURE P GAUGE 10 B RISER CHECK VALVE 11 ® DRAIN CONNECTION 13 (REF.) ® J� y 1" (25 mm) ® MINIMUM CLEARANCE t O LL H FACTORY WATERFLOW ASSEMBLY SHOWN, ALARM ROTATE COMPONENTS SWITCH AT COUPLING JOINTS AS NECESSARY TO ® SYSTEM SUIT INSTALLATION SUPPLY j- lJ - SHUT-OFF VALVE *2" (DN50) ONLY FIGURE 1 MODEL RM-2 RISER MANIFOLD STANDARD ASSEMBLYAND DIMENSIONS 8 7 3 6 14 3 5 4 2 1 2" H TFP964 Page 3 of 6 No Qty Part Description CH Part Specification 2 (DN50) 1 2-1/2 (DN65) 1 3 (DN80) 4 (DN100) 1 6 (DN150) 15 1 Pipe Nipple, Galvanized ✓ 1-1/4" x 5" 2" x 3-1/2" 16 1 Elbow, Galvanized ✓ 1-1/4" x 90° 2" x 90' NOTES 1. CH = Common Hardware Dim. Nominal Dimension in. (mm) 2 (DN50) 2-1/2 (DN65) 3 (DN80) 4 (DN100) 6 (DN150) D 2.6(66) 3.5(89) 3.7(94) 4.6(117) 5.9(150) J 12.2 (310) 12.8 (325) 12.7 (323) 12.0 (305) 13.0 (330) K 7.8(198) 8.4(213) 8.3(211) 7.2(183) 8.2(208) L 3.9(99) 5.0(127) D - J K -I 15 EST AND DRAIN VALVE HOWN TO ILLUSTRATE FERNATE INSTALLATION LOCATION ONLY, JOT INCLUDED IN KIT) FIGURE 2 MODEL TD-2 TEST AND DRAIN VALVE ALTERNATE INSTALLATION KIT ARRANGEMENT Installation The TYCO Model RM-2 Riser Manifold must be installed in accordance with this section. The Model RM-2 Riser Manifold may be installed either horizontally or vertically. Note: Where applicable pipe thread sealant must be applied sparingly. Use of a non -hardening pipe thread sealant is recommended. Never remove any piping component nor correct or modify any piping defi- ciencies without first depressurizing and draining the system. Installing the Riser Manifold Step 1. Install the manifold assembly with the flow arrow embossed on the riser check valve oriented downstream from the water supply, and secure the end -connections with mechanical grooved couplings listed for fire protec- tion service. Note: For horizontal installation, ensure the TYCO Model CV-1FR Riser Check Valve is installed with the valve cover up. For more information, refer to Tech- nical Data Sheet TFP950. Step 2. Connect the drain line and set the Model TD-2 Test and Drain Valve to the CLOSED position. Step 3. Wire the riser manifold in accordance with the wiring guidance in Figure 3. All wiring must be performed in accordance with the authority having jurisdiction and/or the National Electri- cal Code. Step 4. Place the system in service by filling the system with water. When filling the system, partially open the control valve to fill the system slowly. Filling the system slowly helps to avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 5. Secure all supply valves open. L 16 Nominal Equivalent Length of Valvea Size ANSI Size Schedule 40 Pipe ft (m) 2 (DN50) 32(9,7) 2-1/2 (DN65) 31(9,4) 3 (DN80) 31(9,4) 4 (DN100) 36 (10,9) 6 (DN150) 55 (16,7) TABLE A FRICTION LOSS EXPRESSED AS FLOW THROUGH EQUIVALENT LENGTH OF SCHEDULE 40 PIPE Setting the Pressure Relief Valve Step 1. Review the pressure relief valve assembly on the test and drain valve as shown in Figure 3. Step 2. Rotate the pressure relief cap and align the set pressure marks to the the set pressure indicating surface plus (+) or minus (-) a quarter turn. TFP964 Page 4 of 6 UNINSULATED LOOPED SECTION CLAMPING \ PLATE TERMINAL SWITCH TERMINAL CONNECTIONS CLAMPING CAUTION: PLATE SINGLE An uninsulated section of a TERMINAL CONDUCTOR single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve \ as two separate connections, / thereby providing supervision of the connection in the event that the wire becomes IMPROPER CONNECTION METHOD WIRE NUT LOCAL AUDIBLE/VISUAL NEUTRAL ANNUNCIATOR w (WHITE WHITE BLACk ¢Cc l O 00 BLACK (LINE/HOT) 1— CONTACT RATINGS: Two sets of SPDT (Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC SEVERED STRIPPED ENDS SEPARATE CONDUCTORS dislodged from the terminal. OUTGOING PROPER CONNECTION METHOD WIRE NUT 11-=ILL mi�emwi 0 INCOMING FIRE PANEL OR ADDRESSABLE MODULE NOTE: When connecting to a UL Listed control panel, use panel resistor rating for circuit supervision NOTE: For supervised circuits, see "Switch Terminal Connections" above. The Waterflow Alarm Switch has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. FIGURE 3 MODEL RM-2 RISER MANIFOLD WIRING GUIDANCE TFP964 Page 5 of 6 - m - ROTATE TEST ' DO NOT ROTATE VALVE HOUSING AS TEST VALVE NECESSARY FOR HOUSING WHEN IN UNOBSTRUCTED CLOSED POSITION � — Ilia , FULL RANGE OF HANDLE OPERABILITY' TEST II VALVE u (NORMALLY CLOSED) f i / ROTATE HANDLE 180' TO TEST TEST VALVE FLOW OPEN HOUSING / POSITION /CAnTnE:)V N) f / i 0� � CLOSED D POSITION C U I I I I I I I I I I DRAIN CONNECTION DRAIN VALVE HANDWHEEL PRESSUR RELIEF CAP SET PRESSUR MARKS SET PRESSUR INDICATIN SURFACE PRESSUR RELIEF VALVE DRAIN VAL` (NORMALL CLOSED) I I I I I I I I :CID - -' FIGURE 4 MODEL TD-2 TEST AND DRAIN VALVE FEATURES AND FUNCTION MODEL RM-2 - RISER MANIFOLD FLEXIBLE DRAIN HOSE SIGHT GLASS EACH SIDE Flexible Drain Hose Nominal End Connections Valve Size Range ANSI in. Length in. Part NPT Groove (DN) in. (mm) Number (n. 24 (610) 5940124 2 to 3 1-1/4 1-1/4 36 (DN50 to DN80) (DN32) (915) 5940136 24 (610) 5940224 4 to 6 2 2 36 (DN100 to DN150) (DN50) (915) 5940236 DRAIN PIPE 1 Notes: AND FITTINGS O Q 1. Drain pipe and fittings not included Hill HillIll J------------ Hill 1111111 ( FIGURE 5 MODEL RM-2 RISER MANIFOLD OPTIONAL FLEXIBLE DRAIN HOSE TFP964 Page 6 of 6 Care and Maintenance The TYCO Model RM-2 Riser Manifold must be serviced and maintained in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, obtain per- mission to shut down the effected fire protection system from the proper authorities and notify all personnel who may be affected by this action. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION such as NFPA 25, in addition to the standards of any authority having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Note: With the exception of the Model TD-2 Test and Drain Valve and the Model CV-1FR Riser Check Valve, do not attempt to repair any component of the Model PM-2 Riser Manifold in the field. The Drain Valve Handwheel of the Model TD-2 Test and Drain Valve may be replaced in the field. Refer to Tech- nical Data Sheet TFP950 for CV-1FR repair information. Replace other com- ponents as whole assemblies only. See Figure 1 for component descriptions and part numbers. The alarm/flow test procedure results in operation of the associated alarms. Notify the owner and the fire depart- ment, central station, or other signal station to which the alarms are con- nected, and the building occupants. The following inspection procedure must be performed as indicated, in addition to any specific requirements of the NFPA, and any impairment must be immediately corrected: Alarm/Flow Test Procedure Step 1. Rotate the test valve handle 180 degrees to the OPEN position as shown in Figure 4. Note: This action permits water to flow through the orifice of the test valve sim- ulating flow from an individual sprinkler located downstream of the waterflow alarm switch as shown in Figure 1. Note: The test valve housing can be rotated 360 degrees to eliminate equip- ment interference with the test valve handle as shown in Figure 4. Do not rotate the test valve housing in the closed position. Step 2. Confirm water flow through the test port by observing flow at the drain port sight glass. Step 3. Verify proper operation of the waterf low alarm switch at the fire panel, the addressable module, and the local audible/visual annunciator if installed as shown in Figure 3. Step 4. Rotate the test valve handle 180 degrees back to the CLOSED position. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name, including description and part number (P/N). Riser Manifolds Model RM-2 Riser Manifold Specify: Model RM-2 Riser Manifold, Size (specify), P/N (specify) 2in. (DN50) ......................5940601 2-1/2 in. (DN65) ................... 5940611 3 in. (DN80) ......................5940621 4in. (DN100)......................5940651 6in. (DN150)......................5940661 Accessories Optional Flexible Drain Hose See Figure 5 for part descriptions and part numbers. Specify: Flexible Drain Hose, P/N (specify) Optional Test and Drain Valve Alternate Installation Kit Specify: Size Range (specify) Model RM-2 Riser Manifold, Test and Drain Valve Alternate Installation Kit, P/N (specify) 2 to 3 in. (DN50 to DN80)........... 59352691 4 to 6 in. (DN100 to DN150) .........59352692 Replacement Parts See Figure 1 for part descriptions and part numbers. Specify: Model RM-2 Riser Manifold, Replacement (specify part description), P/N (specify) Note: Refer to TFP965 for Model TD-2 Test and Drain Valve replacement parts. 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 m 2021 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON Is a trademark of The Che—r. Company FC, LLC Johnson 01,to Controls • The AGF Manufacturing Inc. Model 2511A TESTANDRAIN° matches all the features and benefits of our Model 2500 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drain- age piping. • The 2" Model 2511A features a groove x groove connection. • The Model 2511A complies with the require- ments of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). • The Model 2511A TESTANDRAIN° is a multi - direction, compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. • The Model 2511A TESTANDRAIN° provides an alternate handle location from the Model 1011A for difficult install situations • Available in 1 " and 11/4" NPT and 2" Groove, with all specifiable orifice sizes 3/3" (2.8K), 7/15" (4.2K), 1/2" (5.6K), 17/32" (8.0K), 5/a" (11.21K, ELO), 3/4" (14.01K, ESFR) and K25 as required by NFPA 13, 2007 Edition (see reverse). R] • The included UUFM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated at 175 PSI. Other pressure settings are available and may be substituted. • Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage -piping outlet. • Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. • A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. • Repair kits including (1) adapter gasket, (1) ball, (2) valve seats, (1) stem packing, and (1) stem washer are avail- able for all TESTANDRAIN° valves. Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. CS2511A 10/09 MODEL 2511A - PLAN VIEW MODEL 2511A - DRAIN To RIGHT DIMENSIONS Orifice Size Available: 3/8", 7/16" 1/2" "/32" ELO (6/8"), ESFR (3/4")*, K25** SIZE A B C D E F G H 1 83/4" 21/4" 11/4" 31/2" 33/8 113/16" 25/8 41/4" (222 mm) (57 mm) (32 mm) (89 mm) (86 mm) (44 mm) (67 mm) (108 mm) 11/4' 101/16" 21/2" 13/8" 37/8" 33/8" 21/8" 31/16" 43/4" (256 mm) (64 mm) (35 mm) (98 mm) (86 mm) (54 mm) (78 mm) (121 mm) 2"t 123/4" 3" 113/16" 413/16 55/8 25/8" 33/4" 57/8" (324 mm) (76 mm) (46 mm) (122 mm) (143 mm) (67 mm) (95 mm) (149 mm) Available on 1 1/4" to 2" size units only ** Available on 2" size units only t 2" M2500 is Groove x Groove only THE MODEL 2511 A PROVIDES ALL OF THE FOLLOWING... From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1 Chapter 8.16.2.4.2 & 8.1 6.2.4.3 Chapter 8.16.2.4.4 Chapter A.8.17.4.2 Chapter 8.17.4.2.2 Chapter 8.17.4.2.4 Chapter 8.17.4.3.1 Chapter 8.17.4.3.2 Chapter 7.1.2 Chapter 8.16.1.2.3* Chapter A.8.16.1.2.3 MATERIALS Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflon° Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid APPROVALS UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC -BSA No. 720-87-SM Provisions shall be made to properly drain all parts of the system. Drain connections, interior sectional or floor control valve(s) - shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Drains shall discharge outside or to a drain capable of handling the flow of the drain. (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion -resistant orifice giving a flow equivalent to one sprinkler... The test connection valve shall be readily accessible. shall be permitted to be installed in any location... downstream of the waterflow alarm. (Dry Pipe System) a trip test connection not less than 1 " in diameter, terminating in a smooth bore corrosion - resistant orifice, to provide a flow equivalent to one sprinkler... The trip test connection... with a shutoff valve and plug not less than 1 ", at least one of which shall be brass. - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. A relief valve of not less than in size shall be provided on the discharge side of the pressure -reducing valve set to operate at a pressure not exceeding 175 PSI. - consideration should be given to piping the discharge from the (pressure relief) valve MADE IN U.S.A. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Job Name: Architect: Engineer: Contractor: SECTION 4 ALARMS AND SUPERVISORY DEVICES c POTTER The Symbol of Protection AWARNING • Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. • Shock hazard. Disconnect power source before servicing. Serious injury or death could result. • Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. General Information The Model VSR is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8" (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional waterflow detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Installation: See Fig. 1 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterflow or within 24" (60 cm) of a valve or drain. VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-3 8 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: • NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F-120°F, (4.5°C - 49°C) - UL • Non -corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090148 Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill. (see Fig. 1) Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Install the saddle strap and tighten nuts alternately to required torque. (see Fig. 1). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number 2" DN50 VSR-2 1144402 21/2" DN65 VSR-2 1/2 1144425 3" DN80 VSR-3 1144403 3 1/2" VSR-3 1/2 1144435 4" DN100 VSR-4 1144404 5" VSR-5 1144405 6" DN150 VSR-6 1144406 8" I DN200 VSR-8 1144408 Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. 95401146 - REV H PAGE 1 OF 3 12/07 CP� POTTER The Symbol of Protection Fig.1 roYERTAMPEBS—H REE UT— AADITT: LASTED BY ROTATMG THE RETARD ADNSTMENT KNOB FROMOTO THE MAX SETFMG (_0 SECONDS), THE TA1E DELAY SHOULD BE SET AT TID? MMH.IGM EEO —TO PREVENT FALSE ALARMS. VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD DO NOT LEAVE COV ER OFF FOR EXTENDED PERIOD OF TIME SOmm ADAPTER ADAPTER TIGHTEN NUTS ALTERNATELY ® � � 20mma2mm MAX. DNSIO ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE MOUNT ON -E SO ARROW ON SADDLE 0 S— ONION ROLL PADDLE M OPPOSFFE DIRECITON OF -BELOW (Flowing water activates device in one direction only) Installation Requirements Model Nominal Pipe Size Nominal Pipe O.D. Hole Size U-Bolt Nuts Torque inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 1.25+.125/-.062 33.0+2.0 20 27 VSR-21/2 21/2 2.875 73.0 VSR-21/2 21/2 DN65 3.000 76.1 VSR-3 3 1 DN80 3.500 j 88.9 2.00+.125 50.8+2.0 VSR-31/2 31/2 4.000 101.6 VSR-4 4 DN100 4.500 114.3 VSR-5 5 5.563 141.3 VSR-6 6 DN150 6.625 168.3 VSR-8 8 DN200 8.625 219A Fig. 3 Typical Electrical Connections NEGATIVE DC OR NEUTRAL AC OSITIVE DC R HOT AC FLOW ZONE 3 PANEL Notes: 1. TheModelVSRhastwo switches, one canbeused to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. 2. A condition of LPC Approval of this product is that the electrical entry must be sealed to exclude moisture. 3. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. 2). Fig. 2 Switch Terminal Connections Clamping Plate Terminal �yG v� GJ,S�,O DwGp Pn-3 WERAWARNING& An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. A CAUTION Waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Fig. 4 Fig. 5 Break out thin section of cover when wiring both To remove knockouts: Place screwdriver at switches from one conduit entrance. I inside edge of knockouts, not in the center. PRINTED IN USA MFG. #5401146 - REV H 12/07 PAGE 2 OF 3 CP� POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Compatible Pipe Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPQ DN (VDS) inch mm inch mm inch mm inch mm inch mm inch mm VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 VSR-2 1/2 21/2 2.875 73.0 0.120 3.05 0.203 5.16 VSR-2 1/2 DN65 3.000 76.1 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 98.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-3 1/2 31/2 4.000 101.6 0.120 3.05 0.226 5.74 VSR-4 4 DN100 1 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 5.563 141.3 0.134 3.40 0.258 6.55 VSR-6 6 DN150 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 1 219.1 0.148 3.76 1 0.322 8.18 0.248 6.3 0.177 4.5 Note: For copper or plastic pipe use Model VSR-CF. Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). Ifprovided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Maintenance Inspect detectors monthly for leaks. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble -free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029055. There is no maintenance required, only periodic testing and inspection. Removal • To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector, then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. Important Notice Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Mounting Dimensions EWS U-BOLT NUT U-BOLT WASHER PIPE SADDLE PIPE PLASTIC PADDLE U-BOLT NOMINAL PIPE DIA. +44,5 mm (+ 1-3/4) FOR DN50 - DN65 (2 - 2-1/ NOMINAL PIPE DIA. +54,0 mm (+ 2-1/8") FOR DN80 - DN200 (3 - 8/ ,IA. mm 4") DWG# 1146-6 PRINTED IN USA MFG. 95401146 - REV H PAGE 3 OF 3 12/07 SECTION 5 FIRE SPRINKLERS tqC00 Worldwide I www.tyco-fire.com Contacts Series DS-1 Dry -Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description TYCO Series DS-1 Dry -Type Sprinklers, 5.61K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are decora- tive glass bulb automatic sprinklers designed for commercial use. Dry -type sprinklers are typically used where: • pendent sprinklers are required on dry pipe systems that are exposed to freezing temperatures for example, sprinkler drops from unheated portions of buildings • sprinklers and/or a portion of the connecting piping are exposed to freezing temperatures; for example, sprinkler drops from wet systems into freezers, sprinkler sprigs from wet systems into unheated attics, or horizontal piping extensions through a wall to protect an unheated areas such as loading docks, overhangs, and building exteriors • sprinklers are used on systems that are seasonally drained to avoid freezing for example, vacation areas NOTICE The Series DS-1 Dry -Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contact the installing contrac- tor or product manufacturer with any questions. The Series DS-1 Dry -Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. Sprinkler Identification Numbers (SINs) 3/4 in. NPT: TY3935 - Pendent TY3735 - Horizontal Sidewall 1 in. NPT: TY3235 - Pendent TY3135 - Upright TY3335 - Horizontal Sidewall Technical Data Approvals UL and C-UL Listed FM Approved NYC Approved under MEA 352-01-E Previous New York City Approval and MEA certification numbers apply to product as shown in this data sheet. In accordance with Section BC 3502 of the Construction Code, current NYC Approvals for use in the City of New York apply to all products that contain UL or FM Approvals and Listings; therefore, not all products currently Approved for use in the City of New York will carry an actual MEA Certifi- cation number. See Tables A and B. Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 3/4 in. NPT 1 in. NPT or ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psi'/2 (80,6 Ipm/bar'/2) Temperature Ratings See Tables A and B Finishes Sprinkler: Natural Brass, Chrome Plated, or Signal White Escutcheon: Signal White, Chrome Plated, or Brass Plated Physical Characteristics Inlet ............................. Copper Plug ............................ Copper Yoke ....................... Stainless Steel Casing ............. Galvanized Carbon Steel Insert ........................... Bronze Bulb Seat ................... Stainless Steel Bulb...............................Glass Compression Screw ................. Bronze Deflector ......................... Bronze Frame ............................Bronze Guide Tube ................. Stainless Steel Water Tube ................. Stainless Steel Spring ..................... Stainless Steel Plug Spring` ................ Stainless Steel Sealing Assembly. Beryllium Nickel w/TEFLON Escutcheon .... Carbon Steel or Stainless Steel ' For 3/4 in. NPT only Page 1 of 10 SEPTEMBER 2021 TFP510 TFP510 Page 2 of 10 PLUG WITH INLET SEALING ASSEMBLY YOKE PLUG INLET SPRING BAND WATER SPRING TUBE CASING GUIDE INSERT TUBE BULB SEAT FRAME 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR — SCREW FIGURE 1 SERIES DS-1, 3141N. NPT, DRY -TYPE SPRINKLER ASSEMBLY PLUG WITH INLET SEALING ASSEMBLY YOKE SPRING INLET BAND WATER TUBE CASING GUIDE INSERT TUBE BULB FRAME SEAT 3 mm BULB VENT HOLE COMPRESSION DEFLECTOR SCREW FIGURE 2 SERIES DS-1, 1 IN. NPT AND ISO 7-R 1 DRY -TYPE SPRINKLER ASSEMBLY Operation When the TYCO Series DS-1 Dry -Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage are in service, water is prevented from entering the assembly by the Plug with Sealing Assembly in the Inlet of the Sprinkler. See Figures 1 and 2. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, and the Bulb Seat is released. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet and allowing the sprinkler to activate and flow water. Design Criteria The TYCO Series DS-1 Dry -Type Sprin- klers, 5.6K Pendent, Upright, and Hor- izontal Sidewall, Quick Response (3 mm bulb) and Standard Cover- age are intended for use in fire sprin- kler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency; for example, UL Listing is based on NFPA 13 requirements. Sprinkler Fittings Install the 3/4 or 1 in. NPT Series DS-1 Dry -Type Sprinklers in the 3/4 or 1 in. NPT outlet or run of the follow- ing fittings: • malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) Do not install the DS-1 Sprinklers into an elbow fittings. The Inlet of the sprinkler can contact the interior of the elbow, potentially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figure 13. You can also install the Series DS-1 Dry -Type Sprinklers in the 3/4 or 1 in. NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet pipe systems. TFP510 Page 3 of 10 3/4 in. NPT TY3935 Pendent TY3935 Pendent TY3735 Horizontal Sidewall with Top of Deflector -to -Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 in. (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) without Escutcheon (Figure 10) Temperature Bulb Finish Natural Chrome White Natural Chrome I White Natural Chrome I White Rating Color Code Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135°F(57°C) Orange 1,2 1,2 1*, 2* 155°F(68°C) Red 175'F (79°C) Yellow 200°F 93°C Green 286°F (141°C) Blue Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 in.) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 in.) ' Light and Ordinary Hazard occupancies only TABLE A 314 IN. NPT SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY -TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS 1 in. NPT (and ISO 7-R 1) TY3235 Pendent TY3235 Pendent TY3335 Horizontal Sidewall with Top of Deflector -to -Ceiling with Recessed Escutcheon with Standard Escutcheon Distance of 4 to 12 in. (Figure 4) (Figure 3) (100 to 300 mm) with Deep Escutcheon with Standard Escutcheon (Figure 5) (Figure 8) without Escutcheon with Deep Escutcheon (Figure 6) (Figure 9) TY3135 Upright without Escutcheon without Escutcheons (Figure 10) (Figure 7) Temperature Bulb Finish Natural Chrome White Natural I Chrome White Natural I Chrome White Rating Color Code Brass Plated Polyester Brass Plated Polyester Brass Plated Polyester 135'F 57°C Orange 1, 2, 3, 4 1, 2, 4 1, 2, 3, 4 1, 2, 4 1*, 2*, 3**, 4 1*, 2*, 4 155°F 68°C Red 175°F 79°C Yellow 200°F 93°C Green 286°F 141°C Blue 1, 2, 4 Notes: 1. Listed by Underwriters Laboratories, Inc. (maximum order length of 48 in.) 2. Listed by Underwriters Laboratories for use in Canada (maximum order length of 48 in.) 3. Approved by Factory Mutual Research Corporation (maximum order length of 48 in.) 4. Approved by the City of New York under MEA 352-01-E 5. The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 in. NPT only Light and Ordinary Hazard occupancies only " Light Hazard occupancies only TABLE B 1 IN. NPT (AND ISO 7-R 1) SERIES DS-1 QUICK RESPONSE, STANDARD COVERAGE DRY -TYPE SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP510 Page 4 of 10 SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 2-3/4" to 48" 1-3/4" DIA. (69,9 to 1219,2 mm) (44,5 mm) IN 1/4" (6,4 mm) INCREMENTS 1 FACE OF CEILING tV 2-3/16" ± 1/8" 3" DIA. (55,6 ± 3,2 mm) (76,2 mm) FIGURE 3 PENDENT TY3235 AND TY3935 WITH STANDARD ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING 1\ I ORDER LENGTHS: 3-3/4" to 48" (95,3 to 1219,2 mm) IN 1/4" (6,4 mm) 2-1/4" DIA. INCREMENTS (57,2 mm) FACE OF CEILING 2 1-3/8" ± 1/8" 2-7/8" DIA. (34,9 ± 3,2 mm) (73,0 mm) FIGURE 4 PENDENT TY3235 AND TY3935 WITH RECESSED ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING 1 ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS MINIMUM 1-3/4" (44,5 mm) DEFLECTOR TO CEILING I FIGURE 6 PENDENT TY3235 AND TY3935 WITHOUT ESCUTCHEON SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING ORDER LENGTHS: 3-1/2" DIA. 1 /2" to 46" (88,9 mm) y (12,7 to 1168,4 mm) IN 1/4" (6,4 mm) 2 �1/2" DIA. INCREMENTS (63,5 mm) I FACE OF CEILING 4-1/4" ± 1/8" (108,0 ± 3,2 mm) 1 FIGURE 5 PENDENT TY3235 AND TY3935 WITH DEEP ESCUTCHEON TOP OF DEFLECTOR ORDER LENGTHS: 5" to 48" (127,0 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) FIGURE 7 UPRIGHT TY3135 WITHOUT ESCUTCHEON 1 IN. NPT ONLY TFP510 Page 5 of 10 ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 2-3/8" ± 1/8" (60,3 ± 3,2 mm) FACE OF FACE OF SPRINKLER MOUNTING FITTING SURFACE 1 I 3" DIA. (76,2 mm) 3.5° 1 SPRINKLER FITTING 1-3/4" DIA. (REFER TO DESIGN (44,5 mm) CENTERLINE 5/16" CRITERIA SECTION) OF WATERWAY (7,9 mm) FIGURE 8 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH STANDARD ESCUTCHEON ORDER LENGTHS: 112" to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 4-1/4" ± 1/8" 2-1/2" DIA. FACE OF (108,0 ± 3,2 mm) FACE OF (63,5 mm) MOUNTING SPRINKLER SURFACE FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) _ 3-1/2" DIA. (88,9 mm) F3.5° CENTERLINE 5/16" OF WATERWAY (7,9 mm) FIGURE 9 TY3335 AND TY3735 HORIZONAL SIDEWALL WITH DEEP ESCUTCHEON ORDER LENGTHS: 5-1/2" to 48" (139,7 to 1219,2 mm)— IN 1/4" (6,4 mm) INCREMENTS MINIMUM 2-1/4" (57,2 mm) FACE OF DEFLECTOR TO SPRINKLER MOUNTING FITTING SURFACE 3.5° -� 5/16" SPRINKLER FITTING (7,9 mm) (REFER TO DESIGN CENTERLINE CRITERIA SECTION) OF WATERWAY FIGURE 10 TY3335 AND TY3735 HORIZONAL SIDEWALL WITHOUT ESCUTCHEON The configuration shown in Figure 12 is only applicable for wet pipe systems where the sprinkler fitting and water - filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Dry -Type Sprinkler has the minimum exposure length depicted in Figure 11. See the Exposure Length section. For wet pipe system installations of the 1 in. NPT Series DS-1 Dry -Type Sprin- klers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1 in. x 1 in. NPT Female Adapter (P/N 80145) • 1 in. x 1 in. x 1 in. NPT Sprinkler Head Adapter Tee (P/N 80249) For wet pipe system installations of the the 3/4 in. NPT Series DS-1 Sprinklers connected to CPVC piping, use in the 3/4 in. x 3/4 in. NPT Female Adapter (P/N 80142). For dry pipe system installations, use only the side outlet of maximum 21/2 in. reducing tee when locating the Series DS-1 Sprinklers directly below the branch line. Otherwise, use the con- figuration shown in Figure 13 to assure complete water drainage from above the Series DS-1 Dry -Type Sprinklers and the branch line. Failure to do so may result in pipe freezing and water damage. NOTICE Do not install the Series DS-1 Dry -Type Sprinkler into any other type fitting. Failure to use the appropriate fitting may result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the inlet Plug or binding of the Inlet Plug • insufficient engagement of the Inlet pipe threads with consequent leakage Drainage In accordance with the minimum requirements of the NATIONAL FIRE PROTECTION ASSOCIATION for dry pipe sprinkler systems, branch, cross, and feed -main piping connected to Dry Sprinklers and subject to freezing tem- peratures must be pitched for proper drainage. Exposure Length When using Dry Sprinklers in wet pipe sprinkler systems to protect areas subject to freezing temperatures, use TFP510 Page 6 of 10 FACE OF SPRINKLER J FITTING EXPOSURE LENGTH (SEE DESIGN DSB-2 CRITERIA INTENDED SECTION) FOR FREEZER STRUCTURES I FIGURE 11 EXPOSURE LENGTH STRAP TIES (ENDS ON OPPOSING SIDES OF BOOT) DSB-2 BOOT ADHESIVE 1-3/4" DIA. (44,5 mm) \ CLEARANCE HOLE INSULATED FREEZER STRUCTURE DS-1 SHOWN WITH STANDARD ESCUTCHEON FIGURE 14 MODEL DSB-2 SPRINKLER BOOT WITH PENDENT SERIES DS-1 DRY SPRINKLER TO WET SIDE SYSTEM OUTLET PLUGGED DSB-2 SPRINKLER INTENDED FITTING FOR FREEZER (SEE DESIGN STRUCTURES CRITERIA SECTION) FIGURE 12 SPRINKLER FITTING HEATED AREA 1-3/4" DIA. (44,5 mm) CLEARANCE INSULATED HOLE FREEZER ADHESIVE STRUCTURE DSB-2 BOOTv, I STRAP TIES DS-1 (ENDS ON SHOWN WITH OPPOSING STANDARD SIDES OF ESCUTCHEON BOOT) FIGURE 15 MODEL DSB-2 SPRINKLER BOOT WITH SIDEWALL SERIES DS-1 DRY SPRINKLER RUN O OUTLET PLUGGED SPRINKLER TFITTING O DRY SYSTEM (SEE DESIGN CRITERIA SECTION) DSB-2 INTENDED FOR FREEZER STRUCTURES __c ]LJ FIGURE 13 SPRINKLER FITTING UNHEATED AREA WRENCH RECESS WRENCH FLAT v PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 16 W-TYPE 7 SPRINKLER WRENCH TFP51O Page 7 of 10 Temperatures for Heated Area' 40°F 50°F 60°F Ambient Temperature Exposed to (4°C) (10°C) (16°C) Discharge End of Sprinkler Minimum Exposed Barrel Length2, in. (mm) 40°F 0 0 0 (4°C) 30°F 0 0 0 (-1 °C) 20°F 4 0 0 (-7°C) (100) 10°F 8 1 0 (-12°C) (200) (25) 0°F 12 3 0 (-18°C) (305) (75) -10°F 14 4 1 (-23°C) (355) (100) (25) -20°F 14 6 3 (-29°C) (355) (150) (75) -30°F 16 8 4 (-34°C) (405) (200) (100) -40°F 18 8 4 (-40°C) (455) (200) (100) -50°F 20 10 6 (-46°C) (510) (255) (150) -60°F 20 10 6 (-51 °C) (510) (255) (150) Notes: 1. For protected area temperatures that occur between values listed above, use the next cooler temperature. 2. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS Table C to determine a sprinkler's appropriate exposed barrel length to prevent water from freezing in the con- necting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insulation that is exposed to the heated area. See Figure 11 for an example. Clearance Space In accordance with NFPA 13, when connecting an area subject to freez- ing and an area containing a wet pipe sprinkler system, the clearance space around the sprinkler barrel of Dry -Type Sprinklers must be sealed. Due to temperature differences between two areas, the potential for the formation of condensation in the sprinkler and sub- sequent ice build-up is increased. If this condensation is not controlled, ice build-up can occur that might damage the dry -type sprinkler and/or prevent proper operation in a fire situation. Use of the Model DSB-2 Dry Sprin- kler Boot, described in Technical Data Sheet TFP591 and shown in Figures 14 and 15, can provide the recommended seal. Installation The TYCO Series DS-1 Dry -Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be installed in accordance with this section. General Instructions The Series DS-1 Dry -Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. See the Design Crite- ria section for other important require- ments regarding piping design and sealing of the clearance space around the Sprinkler Casing. Do not install any bulb -type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) rating to 1/8 in. (3,2 mm) for the 286°F (141°C) rating. • A leak -tight 3/4 in. NPT sprinkler joint should be obtained by applying a minimum -to -maximum torque of 10 to 20 lb-ft (13,4 to 26,8 N•m). • A leak -tight 1 in. NPT sprinkler joint should be obtained by applying a minimum -to -maximum torque of 20 to 30 lb-ft (26,8 to 40,2 N•m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under or over -tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers only in the pendent position, and install upright sprinklers only in the upright position. The deflector of a pendent or upright sprinkler must be parallel to the ceiling. Install horizontal sidewall sprinklers in the horizontal position with their cen- terline of waterway perpendicular to the back wall and parallel to the ceiling. Ensure the word "TOP" on the Deflector faces the ceiling. Step 2. With a non -hardening pipe - thread sealant such as TEFLON tape applied to the Inlet threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Wrench -tighten the sprinkler using either: • a pipe wrench on the Inlet Band or the Casing, see Figures 1 and 2 • the W-Type 7 Sprinkler Wrench on the Wrench Flat, see Figure 16 Apply the Wrench Recess of the W-Type 7 Sprinkler Wrench to the Wrench Flat. TFP510 Page 8 of 10 Note: If sprinkler removal becomes neces- sary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non -hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the escutcheon until it comes in contact with the ceiling or wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn with respect to the outer piece, to hold the Deep Escutcheon firmly together. Care and Maintenance The TYCO Series DS-1 Dry -Type Sprin- klers, 5.6K Pendent, Upright, and Hori- zontal Sidewall, Quick Response (3 mm bulb) and Standard Coverage must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay the time to sprinkler operation in a fire situation. A Vent Hole is provided in the Bulb Seat (see Figures 1 and 2) to indicate if the Dry -Type Sprinkler is remaining dry. Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage for example, an improper installation or an ice plug. Close the fire protection system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Seethe Installation Section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSOCIATION, such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). DS-1 Dry -Type Sprinklers When ordering TYCO Series DS-1 Dry -Type Sprinklers, 5.6K Pendent, Upright, and Horizontal Sidewall, Quick Response (3 mm bulb) and Stan- dard Coverage, specify the following information: • SIN: Pendent — TY3935 or TY3235 Sidewall — TY3735 or TY3335 Upright — TY3135 • 5.6 K-factor • Deflector Style: Upright, Pendent, or Horizontal Sidewall • Quick Response, Standard Cover- age, Dry -Type Sprinkler • Order Length: Dry -Type Sprinklers are furnished based upon Order Length as measured per Figures 3 through 10. After taking the measure- ment, round it to the nearest 1/4 in. increment. • Inlet Connections: 3/4 in. NPT, 1 in. NPT, or ISO 7-R 1 • Temperature Rating • Sprinkler Finish • Escutcheon Style and Finish, as applicable • Part Number (P/N) from Table D The Upright Sprinkler without an Escutcheon (TY3135) is available in 1 in. NPT only. Part Numbers are for 3/4 in. and 1 in. NPT standard order sprin- klers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Refer to the Price List for a complete listing of Part Numbers. Replacement Escutcheons Order replacement escutcheons separately. Note: Style 10 Recessed Escutcheons are shipped as assemblies comprised of closure ring and mounting plate. The included mounting plate is not used for Dry Type Sprinkler applications, discard accordingly. Specify: (specify type), (specify) finish, P/N (specify): Recessed (Style 10) Brass Plated ................. 56-701-2-010 Signal White (RAL9003) 56-701-4-010 Chrome Plated ............... 56-701-9-010 Standard (Push -On) White Color .................. 91-106-0-007 Brass Plated ................. 91-106-2-007 Chrome Plated ............... 91-106-9-007 Deep Brass Plated ..................91-107-2-010 White........................91-107-4-007 Chrome Plated ............... 91-107-9-007 Sprinkler Wrench Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Sprinkler Boot Specify: Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This Part Number includes one (1) Boot, two (2) Strap Ties, and 1/3 oz of Adhesive (a sufficient quantity for installing one boot). TFP510 Page 9 of 10 P/N* 60 - XXX - X - XXX SIN 01 Pendent with Standard TY3935 Escutcheon (3/4 in. NPT) (Figure 3) 02 Pendent with Deep TY3935 Escutcheon (3/4 in. NPT) (Figure 5) 03 Pendent with Recessed TY3935 Escutcheon (3/4 in. NPT) (Figure 4) 04 Pendent without TY3935 Escutcheon (3/4 in. NPT) (Figure 6) 05 Sidewall with Standard TY3735 Escutcheon (3/4 in. NPT) (Figure 8) 06 Sidewall with Deep TY3735 Escutcheon (3/4 in. NPT) (Figure 9) 07 Sidewall without TY3735 Escutcheon (3/4 in. NPT) (Figure 10) 36 Pendent with Standard TY3235 Escutcheon (1 in. NPT) (Figure 3) 33 Pendent with Deep TY3235 Escutcheon (1 in. NPT) (Figure 5) 37 Pendent with Recessed TY3235 Escutcheon (1 in. NPT) (Figure 4) 32 Pendent without TY3235 Escutcheon (1 in. NPT) (Figure 6) 34 Sidewall with Standard TY3335 Escutcheon (1 in. NPT) (Figure 8) 43 Sidewall with Deep TY3335 Escutcheon (1 in. NPT) (Figure 9) 44 Sidewall without TY3335 Escutcheon (1 in. NPT) (Figure 10) 38 Upright without TY3135 Escutcheon (1 in. NPT) (Figure 7) SPRINKLER ESCUTCHEON FINISH FINISHI 0 CHROME PLATED SIGNAL WHITE (RAL9003) 1 NATURAL BRASS SIGNAL WHITE (RAL9003) 2 NATURAL BRASS BRASS PLATED 4 SIGNAL WHITE SIGNAL WHITE (RAL9003) (RAL9003) 8 CHROME PLATED STAINLESS STEEL 1 9 1 CHROME PLATED I CHROME PLATED I TEMPERATURE RATINGS 055 082 180 187 372 480 SAMPLE ORDER LENGTHS2 0 135°F(57°C) 5.50 in. 1 155°F(68°C) 8.25 in. 2 175°F (79°C) 18.00 in. 3 200°F(93°C) 18.75 in. 4 286°F (141°C) 37.25 in. 48.00 in. Notes: 1. Escutcheon Finish applies to sprinklers provided with escutcheons. 2. Dry -Type Sprinklers are furnished based upon "Order Length" as measured per Figures 3 through 10, as applicable, and for each individual sprinkler where it is to be installed. After the measurement is taken, round it to the nearest 1/4 in. increment. Use Prefix "I" for ISO 7-R 1 Connection (for example, 1-60-360-4-055). TABLE D SERIES DS-1 DRY -TYPE SPRINKLERS PART NUMBER SELECTION TFP510 Page 10 of 10 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone A-215-362-0700 m 2021 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Johnson 1 nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; Controls TEFLON Is a trademark of The Chea— Company FC, LLC tqC00 Series TY-FRB, 5.6 K-factor Worldwide I www.tyco-fire.com Contacts Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/ series-ty-frb-5-6K General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb -type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: • A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. • A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.61K, 1/2 in. NPT TY323.... Pendent 5.61K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)` The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi''/, (80,6 LPM/bar'/2) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button......................Brass/Copper Sealing Assembly ... Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw ................. Bronze Deflector..........................Bronze Page 1 of 4 NOVEMBER 2021 TFP172 TFP172 Page 2 of 4 Components: 1 Frame 2 Button 3 Sealing Assembly 4 - Bulb 5 - Compression Screw * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector. can be provided on special request. ESCUTCHEON PLATE 6 - Deflector* DEFLECTOR* SEATING SURFACE 7/16" (11,1 mm) NOMINAL 2" 1 MAKE -IN (50,8 mm) 2" q 1-3/8" (50,8 mm) (34,9 mm) 1 / c 1/2" 7/16" (11,1 mm) NPT** NOMINAL MAKE -IN 1/2" NPT** DEFLECTOR WF FI STYLE 15 or 20 RECESSED ESCUTCHEON 2-7/8" (73,0 mm) DIA. — CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT, QUICK RESPONSE / WRENCH RECESS (USE ONLY END "A") FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH 2-7/8" DIA. _ (73,0 mm) 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8" (15,9 mm) I FLUSH 3/8±5/16" (9,5±7,9 mm) 7 �I MOUNTING 1/8" SURFACE/ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 518 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. _ (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING (57,2 mm) 5/16±1/4" 1/2" (12,7 mm) (7,9±6,4 mm) FLUSH 1 I ? I1 M�G 1/8" SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3, (34,9 mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFP172 Page 3 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS CHROME PLATED POLYESTERC 135°F (57°C) Orange UPRIGHT (TY313) 155°F (68°C) Red 175°F (79°C) Yellow and 1, 2, 3, 4, 5, 6 5.6 1/2 in. NPT PENDENT (TY323) 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange RECESSED PENDENT (TY323) Figures 4a and 56 1, 2, 3, 4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) 6. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion -Resistant Sprinklers. a. Installed with Style 15 (1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb -type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) forthe 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak -tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N•m). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over -tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe -thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N•m). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe -thread sealant applied to the pipe threads, hand -tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N•m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP172 Page 4 of 4 P/Na 77 — XXX — X — XXX SIN SPRINKLER FINISH 370 5.6K UPRIGHT (1/2 in.NPT) TY313 1 NATURAL BRASS 371 5.6K PENDENT (1/2 in.NPT) TY323 3 PURE WHITE (RAL9010)a POLYESTER Notes: I I SIGNAL WHITE (RAL9003) a. Use suffix "I" for ISO 7-1 connection; for example, 4 POLYESTER 77-370-4-175-I 5 I JET BLACKPO YEST ER 005) 9 1 CHROME PLATED Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non - operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. TEMPERATURE RATINGS 135 135°F (57°C) 155 155-F (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 1 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 0 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks d National Flre Protection Association; TEFLON Is a trademark of The Chemo Company FC, LLC Johnson 01,to Controls SECTION 6 MISCELLANEOUS �Ctaulicr PRODUCT DESCRIPTION SA4-000-0000 SA2-000-0000 �-1 I I ' SA3-000-0000 Victaulic Automatic Sprin- kler Cabinets provide for storage of a supply of sprin- klers. Maintaining a supply of spare sprinklers on the premises of automatic SA1-000-0000 spri nklersystems will aid in the prompt replacement of operated or damaged spri n- klers and returning a fire protection system to ser- vice as soon as possible. TECHNICAL SPECIFICATIONS Models: 12 sprinklers 6 spri n klers 3 spri n klers (NFPA/3D, Residential) 6 large sprinklers Material: Heavy gauge steel, red enamel. This is a requirement of NFPA and most Authori- ties Having Jurisdiction. Refer to the applicable NFPA standard governing your specific installation for further details. Six or twelve sprinkler capacity cabinets are avail- able. This also provides for storage of the appropriate wrench which is required for the installation and removal of sprinklers. NFPA 25 requires the total number of spare sprinklers to be stored on the pre- mises of an automatic sprinkler system meet the minimum quantitiesshown Cabinets are available in six or twelve sprinkler capacities with dimensions and shelf variations as shown on page 2. The cabi- nets are of welded construction fabricated from low carbon steel sheet. The box and shelves are fabricated from 0.030" thick material and the cover isfabri- cated from 0.042" thick material. VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Sprinkler Cabinets in the accompanying table. When the sprinkler system includes more than one type of temperature rating sprinkler, the stock of spare sprinklers must include proportional sampling of each type and temperature rating; however, a mini- m u m of 3 each is recom- mended. Sprinklers in Building Min. Number of Spare Sprinklers Under 300 6* 300 to 1000 12 Over 1000 24 *A minimum of three sprinklers of each type and temperature rating are required for residential fire sprinkler systems in one- and two-family dwellings and mobile homes. The cover is mounted to the box, at the top, with two 0.036" thick steel butt type hinges. A coat of red enamel paint is applied inside and out, and a label indi- cating that the cabinet is for spare sprinklers is bonded to the cover. Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Ifiorte 1-800-RCK MC (1-800-742-5842) Rmna 416-675-5575 Rtore32- 9-381-1500 Rhona 610-559-3300 Rhona 655-235-3035 Fac 610-250-8817 Fac 416-675-5565 Fac 32-9-380-4438 Fac 610-559-3608 F&c 65-235-0535 en>il:pdcvioa@Adalic.com e-ndl: viocaradacMdalic.00m enal: vioaaro@Actaulic.be enel: vid u@idaalic.00m eiTril: vicq3@Actailiaoom 2561 Rev.B 7/02 ® Registered Trademark of Victaulic © Copyright 2002 Victaulic Printed in U.S.A. DIMENSIONS Victaulic Dimensions — Inches/millimeters H W D Part Number Description Use With V10, V26, V29, V27, V34 (except 5.25 14.31 4.00 SA1-000-0000 For 12 Sprinklers V3403 & V3404) 133 364 102 SA2-000-0000 For 6 Sprinklers P V27, V3403, V3404, V34 133 133 14.31 364 2. 38 60 SA3-000-0000 For 3 Sprinklers (NFPA 13D) V27, V29 Residential 5 25 186 7.31 2608 V40, V38, V39 Concealed, K1 ESFR, SA4-000-0000 For 6 Large Sprinklers All Intermediate Level Sprinklers, 6.50 14.31 3.13 All Guards' 165 364 79 Specify part number and capacity when ordering. 'Guards will only fit if NOT assembled to sprinkler. Capacity may be reduced. INSTALLATION • Automatic Sprinkler Cabinets must be installed and the spare sprinkler stock maintained in compliance with the applicable standards of the NFPA, i n additi on to the standards of any other Authorities Having Jurisdiction. Fai I ure to do so may result in property damage and i mpai r the abi I ity to return an automatic sprinkler system to ser- vice as soon as possible. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. 0 CAUTION • The owner is responsible for maintaining a supply of spare sprinklers in proper condition. The installing contractor should be contacted with arty questions. Failure to do so may result in property damage. 40.81 - 2 This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.