Loading...
APPROVED ENG PLN BLD- BLD2022-0890+Site_Plan+7.7.2022_1.06.53_AM+2974239APPROVED BY PLANNING Setbacks Required Actual Front 25 25 RECEIVED Side 10/35 12.5 (52.33) Jul 08 2022 Side 10/35 39.67 Jul 31 2022 DEVCI OF E O MENDTSERDVCES lk Rear 25 32.08 M DEPARTMENT APPROVED OBTAIN ELECTRICAL ALL WORK SUBJECT PLANS MUST BE PERMIT FROM TO FIELD ON JOB SITE STATE LABOR & INSPECTION FOR INDUSTRIES CODE COMPLIANCE SUCTION ENTRAPMENT AVOIDANCE FOR POOLS SHALL BE PROVIDED IN ACCORDANCE WITH APSP 7. J — - — - — - — - — - — - — - — - — - — - r— — — — — — — — — — — — — — — — — — — — —I MAINTAIN CLEAR ZONE OF NOT LESS THAN 36" BETWEEN THE POOL BARRIER AND POOL ' EQUIPMENT AND EQUIPMENT PAD. REFER TO 2018 ' INTERNATIONAL SWIMMING POOL AND SPA CODE (ISPSC) 305.2.9 I L_ — — — — — — — — — — — — — — — — — — — J Zone _ RS-20 Corner _ _ ' Fla 9 '— Proposed Setbacks: Required Front S 25 25+ 70 Sides W 10/35 _ t0+.....:........• ` Rear N 25 32 72 Side E ;_ 10/35 39.5 74 15 Height 4.5 ------ - 476 Fain Garden City Of Edmonds Building Department ------------------------- Work : ABOVE GOLIND POOL ----------------------------- Address : 7017 174TH ST SW Owner RIXMANN Approved Date' 08/04/2022 Building Official! /te ;r 6100, d,e& Permit Number BLD2022-0890 Proposed pool wall height is 52", so it will serve as the required barrier. No additional fencing required. Access will be via a removable ladder from ground level. Adjacent pool equipment pad will be simple concrete block and accommodate pool pump and heat pump (120K BTU). A thermal cover will be utilized to conserve energy when the pool is not in use. r- — - — - — - — - — - — - — - — - — - — - — - — -� POOLS SHALL COMPLY WITH SECTIONS R403.10.1 through R403.10.4.2 OF THE 2018 WSEC AND SECTION 303 2018 ISPSC. I '— — — — — — — — — — — — There appears to be an easement along the east and north property lines. Do not place the pool, retaining walls, etc within %the easement. ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF ,F Existing 4' Retaining Walls F` EDMONDS STANDARD DETAIL SD-642 OR i APPROVED EQUAL. 76,78 84 80/ OWNER/CONTRACTOR IS RESPONSIBLE FOR ''•."- �-` EROSION CONTROL AND DRAINAGE s Pool Equipment (Pump) Pad' Removable Pool Ladder ................ RSh1d Existing On -Grade Patio / 4 12'6" ► OWNER/ CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. 86 Proposed 24' Round Above Ground Swimming Pool, 52" Depth Tub Sanitary Tee for Pool Drainage An AVB valve shall be 88 used when filling the pool. 90 Existing Existing SFR Slotted 92 Deck 18' 6" ► 1 1 SFR 94 ♦i o N ♦ i Applicant shall repair/replace all 'I'- damage to utilities or frontage improvements in City right-of-way ! ......................"""" per city standards that is caused or ' 96" ' occurs during the permitted project. 98* 174th Street SW Site: Drawing: Project Drawn: Notes: RIXMANN 7017 174th St SW 1 Robert Rixmann Title 24' Round Above Ground Swimming Scale: Date: Rev: Pool Installation 1":20' 07/06/2022 A ENGINEERING DIVISION APPROVED AS NOTED 08/05/2022 NO STORMWATER MANAGEMENT SYSTEM REQUIRED AT THIS TIME. IF NEW AND/OR REPLACED IMPERVIOUS SURFACE EQUALS 2000SQFT OR GREATER, A STORMWATER MANAGMEMENT SYSTEM MAY BE REQUIRED PER CITY CODES AND STANDARDS