Loading...
REVIEWED BLD2022-0284+Structural_Calculations+3.3.2022_10.31.13_PM+2716805Structural Design Associates 3006 Rucker Ave. Everett, WA 98201-3774 Phone: (425) 339-0293 Email: admin@sdaeverett.com STRUCTURAL CALCULATIONS LATERAL, GRAVITY, FOUNDATION SDA Job # 9371 SEP 2 9 2021 FEB 1 0 2022 WALLA ADDITION 10406 226TH PL SW EDMONDS, WA 98020 September 23, 2021 WALLA ADDITION mber 23, 20211 SDA Job # 9371 Scope of Work. LATERAL, GRAVITY, FOUNDATION Site Address. 10406 226TH PL SW EDMOND_S. WA 98020 Number of Stories: 1 Engineer: Reviewed by: Risk Category: II BLDGS EXCEPT I, III. & IV) Construction Type: LOW RISE - RESIDENTIAL Roof Level Loading: Roofing Composition Sheathing 15/32" Plywood 1 o Insulation Roll/Batt Ceiling 5/8" GWB a Uj Framing Trusses fixtures, mechanical, electrical, partitions etc. QMiscellaneous LIVE LOAD: 20.0 psf TOTAL DEAD LOAD: WALL DEAD LOAD: 10.0 psf ROOF SNOW LOAD: Grade_ I Level Loading. Floor Covering Sheathing Ceiling Joists Beams Miscellaneous WALL DEAD LOAD 10.0 NA I Level Loading: _ Floor Covering Sheathing Ceiling Joists Beams Miscellaneous WALL DEAD LOADII 10.0 osf NA J Level Loading Floor Covering Sheathing Ceiling Joists Beams Miscellaneous NA WALL DEAD LOAD 10.0 osf j Soil Bearing Capacity: 1500 psf j Frost Depth: 18 in l TOTAL DEAD LOAD FLOOR LIVE LOAD TOTAL DEAD LOAD; FLOOR LIVE LOAD: TOTAL DEAD LOAD: FLOOR LIVE LOAD: CRL CCC 3.0 1.5 3.0 2.8 2.2 2.5 15.0 1 25.0 1 12.0 100.0 12.0 100.0 12.0 100.0 WALLA ADDITION September 23, 2021 SDA Job # 9371 Type of construction: LOW RISE - RESIDENTIAL Location: 10406 226TH PL SW Applicable Building Codes: 2018 IBC, ASCE 7-16 _ EDMONDS, WA 98020 Work performed LATERAL, GRAVITY, FOUNDATION WIND DESIGN: Ps = APs30Kzt Enclosure Classification: ENCLOSED . SIMPLE DIAPHRAGM PER ASCE 7-16, 26 2 Exposure : B Wind Exposure Category as set ionh in 201E IBC, Section 1609 4 Wind Speed = 110 MPH Basic Wind Speed as used in ASCE 7-16, Figure 26 5-1(A-D) VASE) = $6 MPH Allowable Stress Design Wind Speed A = 075 Adjustment factor for building height and exposure from Figure28.5-1 of ASCE 7-16 KZT = 1 33 Adjustment factor for increased wind speed due to a hill or escarpment Roof slope rise Front/Rear tan-1 { 4 run / 12 � - 18 4 degrees Number of floors: Left/Right tan-1 ( 4 1 12 = 18 4 degrees 11 ft Mean Elevation Average uplift (F/R)= -14,0 sfEE] Based on wind zones 'G' and 'H' Average uplift (R/L)= -14 p psf Based on wind zones 'G' and 'H' End zone of wall End zone of roof Front/Rear Left/Right Front/Rear Left/Right Ps30= A = 25.8 psf 25.8 psf B = -7 3 psf -7 3 psf Ps= 25.9 psf 25 9 psf -7 3 psf -7 3 psf Interior zone of wall Interior zone of roof Front/Rear Left/Right Front/Rear Lett/Right Ps30= C = 17 2 psf 17 2 psf D = -4 1 psf -4 1 psf Ps= 17 2 psf 17 2 psf -4 1 psf -4.1 psf FRONVREAR ZONES iV Roof = rib I Transverse WIND ZONE A B C C C D D D D D AVE. HEIGHT 3.5 5.75 3.5 3 4 5.75 1 -1.5 -3 -4 AVE. WIDTH 9 11 54.25 9.5 12 55 17.5 5.5 9.5 12 Ps 25.89 0.00 17.22 17.22 17.22 0.00 0.00 0.00 0.00 0.00 U0 0,00 SUBTOTAL 816 0 3269 491 826 0 0 0 0 0 0 0 TOTAL :9.762 Ibs ............ ..................... . Minimum net pressure controls. The calculated pressure is less than the minimum net pressure, equal to 16nsf npiied over the entire area. fASCEL-JUT.1.5) cV c Fmnaa = WIND ZONE AVE. HEIGHT AVE. WIDTH Ps 0.00 0.00 0.00 0.00 000 0.00 0.00 0.00 0.00 0.00 0.00 0.00 SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL t01hs c v rvH = VVINO ZONE AVE. HEIGHT AVE, WIDTH Ps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0,00 0.00 SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL !0lbs M7U_ W3 WIND ZONE AVE Rs 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0-00 0.00 SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL :Olbs WALLA ADDITION I September 23, 2021 1 SDA Job# 9371 1 2 LEFT/RIGHT ZONES EV Roof = WIND ZONE A B C C D D D D AVE HEIGHT 3-5 575 3 5 5.5 5.75 0,5 2.5 4 AVE. WIDTH 9 11 57.75 16.75 21 24 8 30-5 PS 25.89 0-00 17.22 17.22 0.00 000 0.00 0-00 0.00 0.00 0.00 0-00 5U8TQTAL 816 0 3480 1586 0 0 0 0 0 0 0 0 TOTAL 110.620 Ibs Minimum net pressure controls. The calculated pressure is less than the minimum net pressure, equal to 16 sf ao lied over the entire area. (ASCE 7-10 27 1 5) c v uraue WIND ZONE AVE. HEIGHT AVE. WIDTH Ps 0.00 0-00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1 0.00 0.00 0.00 SUBTOTAL 0 1 0 0 0 0 0 0 0 0 0 0 0 TOTAL I01bs PAW ■_1E ZONE- UUH AVE- WIDTH Ps 0-00 0.00 0-00 0.00 1 0.00 0.00 0,00 000 0.00 0-00 0.00 0.00 SUBTOTAL 0 0 0 0 1 0 0 0 0 0 0 0 0 TOTAL ;Olbs ZV NA = WIND ZONE AVE. HEIGHT AVE. WIDTH Ps 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0-00 0.00 SUBTOTAL 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 10lbs 5EISMIC_LOAD p CALCS fASCE7.16 &12.3.41- Plate Height: 9.00 ft Total length of Shearwall in Shortest Line: 20.50 ft Length of Shortest Segment within Shear Line: 20.50 ft Length of Longest Segment in Shear Line: 20.50 ft Plate Height: Total length of Shearwall in Shortest Line: Length of Shortest Shearwall within Shear Line: Length of Longest Wall in Shear Line: NA Level Calculations Plate Height; Total length of Shearwall in Shortest Line: Length of Shortest Shearwall within Shear Line: Length of Longest Wall in Shear Line: NA Level Calculations Plate Height: Total length of Shearwall in Shortest Line: Length of Shortest Shearwall within Shear Line: Length of Longest Wall in Shear Line: Tributary Area: 1 1.0 Total Area: 1 2.0 p = 1.00 ASCE 7-16 12 3 4.2 b Tributary Area: 1.0 Total Area: 2.0 p = NA Tributary Area: 1.0 Total Area: 2-0 p = NA Tributary Area: 1.0 Total Area: 2.0 p = NA WALLA AUDI I ION I September 23, 2021 1 SDA Job# 9371 1 3 SEISMIC LOAD: (ASCE7-16 §12.8) nlsps:r�rsexares ascounc i ur�� Flexiable Diaph.? YES v=C,W Irregularities? YES ME M§PQNSE ANALYSISMEQUIREMENT (11.4.71 C,=SD5/(R/l�) Risk Category = II Risk Category DESIGN WITH SEISMICALLY ISOLATED STRUCTURE? NO Cs M,N_C. 5E2-0ss,/(R/le) p = 1 00 Redundant DESIGN STRUCTURE WITH DAMPING SYSTEM? .�NO Cs %11N CA E1=0.044SD5!,>0.011 Site Class = D - DEFAULT cs Mix=sD,/(r(R/IQ) IE = 1 (Table 1,5.1) NOT REQUIRED: 11 4 8 E 2, Cs MODIFIED AS REQUIRED BY EXCEPTION T<T,, Cs=SD,/R(R/le) hn _ . 15 Structural Height T>T, , Cs=S,,T, rV (R1I,) E=C,p §11 4 4 Ss = 128 1 % TYPE: (T12.2-1) Ta (s) R no Cd Cs E S,N,s=Foss = 153.7% §11 4 4 Fa = 1.20 1) SDS-2/,S,, = 102.5% 51144 Si = 45.0% 2) SDS'-SDS = 102.5% §12.8 1 3 Fv = 1.95 3) Sr,,rt=F Si = 87.9% § 11 4 5 SDC = D 41 Su1=z/35N11 = 58.6% §1145 Tit 6 B Ts=Sol/SDS = 57,2% §11 4 6 W (ROOF) _ W (FLOOR) _ W (WALL) = Roof Level Diaphragm Loading: A15 - WSW 1 0 15 6.50 2.50 4.00 0.158 0.158 G6 - TF 0.15 1.50 1.50 1.50 0.683 0.683 LENGTH WIDTH COEFF LOAD TOTAL 60.5 60.5 1.1 150 57649 1.0 15.0 0 1.0 150 0 1.0 150 0 1.0 150 0 Area = 3660 Sub -Total= SM49 Ili LENGTH WIDTH LOAD TOTAL 12.0 0 12.0 0 12.0 0 12.0 0 120 0 Area= u NUD-I0[a1= In NUMBER LENGTH TRIB, HT LOAD TOTAL 2 64 4,5 10.0 5760 2 67 4.5 100 1 6030 1&0 1 0 Area = 590 Sub -Total= 11790 TOTAL = 69439 lb iW WALLA ADDITION I September 23, 2021 SEISMIC 01STRIRUTION FOR- A15 . WSW Q=A s III 2) IV (ROOF) _ IV()= EV()= EV()= TOTAL = IV (ROOF) EVO= IV()= IV()= TOTAL FV Y-V x p height FV x height 10948 lb 10948 lb 11 120426lb 10041J 11) 1s 9Q3 Ib 1Z042ti Ib SEISMIC DIS'fRtBUTION FOR- C.6 - TF. R=1.5 FV ZV x p height LV x height 47441 lb 47441 lb j 11 521848lb 414,11 Ib 4 i 441 Ib 521846 Ib I INFAC_TnRF n I nAn St ITAmARV • SDA Job# 9371 ! 4 REDISTRIBUTE: E f ) 10948 Ib ZV x h9ight x IV TOTAL = FV x height TOTAL REDISTRIBUTE: E ( ) 47441 Ib XV x height x EV TOTAL = FV x height TOTAL LEVEL WIND SEISMIC A15 - WSW G6 - TF Ft-Rr) (Lt-Rr) FV (Roof) = 9762 Ibs 10620 Ibs _ 10948 Ibs 47441 Ib NOT APPLICABLE NOT APPLICABLE NOT APPLICABLE TOTAL BASE SHEAR= 97621bs 106201bs 10948 Ibs 47441 Ib WALLA ADDITION September 23, 2021 j SDA Job# 9371 1 5 IRREGULARITY: Increase in force due to irregularities for seismic design categories D-F (per ASCE7-16. 12.3.3.4)- Yes Seismic T 25% for collector & diaph. Affected Levels; T. Out -of Iarte offset with discontinuity, including out -of -plane offset of at least one vertical elements T12 3-1. T` a 4) Yes Seismic x 00 for diaphragm loading Affected Levels. One or two-family dwelling of light frame construction Yes :• 00=1 0 (§12,10.1.1) y no -1 2.50 FLEXIBLE DIAPHRAGM DESIGN (ASD EV [RO&I - % of load transfer =7�64.0 (Percentage of load transferred through diaphragm) Total diaphragm length = Sub -diaphragm length = 0.6 x FV (Roof) = 6,372 IbS FACTORED WIND (LEFT -RIGHT) -•> Location @ 253 PLF x S-G. = 0 ft Diaphragm width = 0.7 x FV (Roof) = 7.664 Ibs FACTORED SEISMIC I rho Location @ 240 PLF x S.G = 0 ft. Aspect Ratio = _ ASDxFV(FLOOR) _ 16372 Ibs , 7664 Ibs] v (2)(width)(S.G) 2 x 64 ft. x 0.93 = [WIND=54 PLF, SEISMIC=65 PLF] Seismic Governs! 2015 SDPWS T4.2A & T4.2C `NOTE: SEISMIC MAY GOVERN OVER WIND DUE TO HIGHER WIND CAPACITY CUSE: 15/32" SHEATHING WITH 2x HEM -FIR FRAMING; FASTEN AT PANEL EDGES WITH 8d @ 6" O/C WALLA ADDITION Seplember 23, 2021 SDA Job# 9371 G CHORD DESIGN: EV (Roof) = Sub -diaphragm length = 64-0 ft Total -diaphragm length = 67.0 ft Design Load (critical case) = 64 PLF Sub --diaphragm width = 64 0 ft T = M = "iV(unit shear) x (diaphragm length) _ 65 PLF x 67 ft. = 540 Ibs �— 8 � 'SEE DIAPHRAGM DESIGN FOR EV(unit Top Plate Size: 2xfi Species/Grade: HF #2 shear) Area = B 25 in"2 Ft = 525 psi Load duration (CD) = 1.60 Tallowable = Area x CD x Ft = 6,930 Ibs Since T allowable is greater than T applied, OK. SHEAR CAPACITY OF 10d COMMON NAIL = 102 Ibs 102 x Cd x p = 163 Ibs 2018 NOS 539 Ibs USE: 2x6 HF #2 TOP PLATE w/ (8) 10d # OF NAILS PER 4FT. SPLICE = 163 Ibs = 4 NAILS COMMON NAILS PER SPLICE WALLA ADDITION I September 23, 2021 j SDA Job# 9371 1 7 Lateral Calculation Key - for Shearwalls Only (See attached calcs for other lateral load resisting system designs) i P2 V V = Shear, plf H = Height of shearwall L = Length of shearwall 096 P1 = Weight of shearwall and connected framing P2 = Weight of adjacent wall IPl j } *T = V x H - 0.5P1 - P2 = Tension reaction to be resisted by holdown T C C= V x H+ 0.5P1 = Compression reaction `Holdown tension load supporting roof framing includes wind uplift from'Zone G' & 'Zone H' ASD Basic Load Combinations For calculation of tension and compression forces in compliance with A SCE 7-16 2.4 1 Tension Eauations [Uplift 7. 0.6D +0.6 W 8**. (0.6-0.14SDS)D+0,7Emh 10. 0.6D-0.7Ev+0.7Eh 10*. 0.6D-0.7Ev+0.7Emh Compression Equations 5. D+0.6W 5** (1+0.14SDS)D+0.7Emh 6. D+0.75L+0.75(0.6W)+0.75S 6b**(1+0.105SDS)D+0,525Emh+0.75L+0.75S 8. D+0.7Ev+0.7Eh 8* D+0.7Ev+0,7Emh 9 D+0.525Ev+0.525Eh+0.75L+0.75S 9* D+0.525Ev+0.525Emh+0.75L+0.75S LRFD Basic Load Combinations (Where Applicable) For calculation of tension and compression forces in compliance with ASCE 7-16 2.3.1 Tension Eauations (Uplift) ) 5. 0.9D+W 7.0.9D-Ev+Eh 7*. 0.9D-Ev+Emh 7**. (0.9-0.2SDS)D+Emh Compression Eauations 4.1 2D+1.6W+L+0.5S 5** (1+0.2SDS)D+Emh+L+0.2S 6. 1.2D+Ev+Eh+L+0.2S 6 1.2D+Ev+Emh+L+0.2S Load-sy-mboljgagrid: D Dead load L - Live load S - Snow load W -Wind load SIDS - Design spectral response acceleration Eh - Effect of horizontal seismic forces Ev - Effect of vertical seismic forces Em - Effect of horizontal seismic forces, including overstrength Emh - Vertical seismic load effect IW11reWa4lnn,�vrtb4t LCBen�!-. HD - HOLDOWN Shgar Wall CoeffteienLUgea+lr (see 'SE SjMENTQD SHEAR WAIL DE5&q catlxsl WL FACTOR - Factor for increasing seismic capacity to wind load capacity per SDPWS-2015 T4.3A. ASPECT RATIO - Full -height segmented shear wall reduction factor per SDPWS-2015 4.3.3.4.1. Shear walls with similar stiffness per 4.3.4.2. TOTAL ADJ. LENGTH - Sumation of shear wall segments widths adjusted with aspect ratio (as required). S.G. - Specific Gravity Adjustment Factor for Hem -Fir Framing (may be increased to 1.0 for Douglas -Fir framing). ASD -Allowable Stress Design load combination factor. ALLOWED UNIT SHEAR - Unit shear capacity per SDPWS-2015 T4.3A. Shear values adjusted with FACTOR OF SAFETY per 4.3.3. WIND CAPACITY - Ultimate shear value calculated per W L FACTOR x S.G. x UNFACTORED SHEAR CAPACITY / (FACTOR OF SAFETY x ASD). SEISMIC CAPACITY - Ultimate shear value caulated per: S.G. x UNFACTORED SHEAR CAPACITY / (FACTOR OF SAFETY x ASD), f WALLA ADDITION j September 23, 2021 SDA Job # 9371 j 8 Main Front I A15- WSW ISEGMENTED WALL Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Lt-Rt Load Direction, a g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4,3A of SDPWS-2015) ROOFJ Resisting Dead Load Shearwall Segment Lengths. A411. Total Lcngib = 20 5 It 205ft FV (ROOF) = 10620 lb FVO= 0lb EV()= 0lb FV()= 0lb E (Wind) = 10,620 lb ULT. v = 259 PLF 10948 lb 0 lb 0 lb 0 lb E (Smc) = 10,948 Ito ULT. V = 267 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF I (2 x 0.6) = 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF / 2 x 0.71 = 305 PLF Holdown Above: NO FLOOR ABOVE ASO C TOTAL = (floor above) + (this floor) = ASD T, TOTAL w/o 00 = (floor above) + (this floor) = Unfactored C WL = 2331 Ibs Unfactored T WL = 2703 Ibs Unfactored C EQ = 2403 Ibs Unfactored T EQ = 2403 Ibs Unfactored C DL = 1590 Ibs Unfactored C.LL/SL = 663 Ibs Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Lt-Rt Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths_: Atli TotalLentiffi-I 27 6 ft 45ft 1 45ft 1 8.0ft 1 75ft 1 38ft EV (ROOF) = 10620 lb FVO= 0lb IV U = 0 lb FVO= 0lb E (Wind) = 10,620 lb ULT. V = 192 PLF 10948 lb 0 Ib 0 lb 0 lb F (Smc) = 10,948 lb ULT. V = 198 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF / (2 x 0.6) = 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF / (2 x 0.7) = 305 PLF Holdown Above: NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) _ ASD T. TOTAL w/o 00 = (floor above) + (this floor) _ Unfactored C WL = 1730 Ibs w Unfactored T WL = 3251 Ibs Unfactored C EQ = 1783 Ibs Unfactored T EQ = 1703lbs Unfantarad C. ❑L - 2199 Iba Unfactored C_LLJSL = 27" lbs Tributary Area (ROOF) 10 tributary width 20 total width Tributary Area (NA) tributary width total width Q9 Tributary Area (NA) z tributary width 0 O total width o Tributary Area (NA) Z tributary width 3 total width Height of Shearwall = 9 0 ft Length of Shearwall = 20 5 It Aspect Ratio OK rnbulaiy Area (ROOF) I 0 tributary area 2.0 total area Tributary Area (NA) tributary area total area z Tributary Area (NA) a tributary area total area u Tributary Area (NA) —^ tributary area total area Weight of Shearwall = 10 0 Ibs Tributary width for dead load = 2 0 ft Length of adjoining wall = 3.0 ft R= 65 LRFD Holdown Design? No Do = 25 Ductile Anchor Design? No Block Shear Wall USE. 1 Seismic controls shearwall design 0 Ibs + 1910 Ibs = 1910 Ibs Seismic controls -C3 (ASD eq 8): 0 Ibs + 956 Ibs = 956 Ibs Seismic controls -T2 (ASD eq. 10): SIMPSON DESIGNED HOLDOWN CS14 FOUNDATION / INTERIOR WALLS: LSTHDB/RJ Tnbufary Area (ROOF) Tributary Area (ROOF) 1 0 tributary width 1.0 tributary area 2 ❑ total width 2.0 total area Tributary Area (NA) Tributary Area (NA) total �totalarearea width total width total area Tributary Area (NA) z Tributary Area (NA) o tributary width atributary area a 0 total width 0 total area o Tributary Area (NA) Tributary Area (NA) z tributary width w tributary area total widthI total area Height of Shearwall = 9.0 ft Length of Shearwall = 3.8 ft Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 17 0 H Length of adjoining wall = 4 5 ft R= 65 LRFD Holdown Design? F No­__J Do = 2 5 Ductile Anchor Design? No Block Shear Wall USE 1 Seismic controls shearwall design 0 Ibs + 1564 Ibs = 1564 Ibs Seismic controls -C3 (ASD eq 8): 0 Ibs + 631 Ibs 631 Ibs Wind controls -T1 (ASD eq. 7): SIMPSON DESIGNED HOLDOWN: CS14 FOUNDATION / INTERIOR WALLS: H / J WALLA ADDITION ISeptember 23, 2021 SDA Job # 9371 1 9 Main Left I A 15 • WSW ISEGIVIENTED MALL Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Ft-Rr Load Direction, a g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths, Aat. Total t.auglh = 35 0 ft 350ft EV (ROOF) = 9762 lb EV()= 0lb EVO= 0lb EV()= 0lb E (Wind) = 9,762 Ib ULT. v = 139 PLF 10948 lb 0 lb 0 lb 0 lb E (Smc) = 10,948 lb ULT. v = 156 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF / (2 x 0.6) - 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF 1 (2 x 0.7) = 305 PLF Holdown Above: NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) _ ASD T. TOTAL w/o 00 = (floor above) + (this floor) _ Unfactored C WL - 1255 Ibs Unfactored T WL = 2490 Ibs Unfactored C E0 = 1408 Ibs Unfactored T EQ = 1408 Ibs ' Unfactored C DL = 3300 Ibs Unfactored C LL/SL = 2200 Ibs I ib7 Floor Info ROOF Floor Level, e.g. Roof, 4TH, 3RD, 2ND Ft-Rr Load Direction, e.g. Left -Right, Front -Rear (For Left Wall, Use Front -Rear Load Direction) CDX Sheathing type (T4.3A of SDPWS-2015) ROOF Resisting Dead Load Shearwall Segment Lengths: Adj. Total Length = 29.0 ft 29.0 ft EV (ROOF) = 9762 lb EVO= Olb EVU= 0lb EV()= 0lb 3 E (Wind) = 9,762 lb ULT. v = 168 PLF 10948 lb 0 lb 0 lb 0 lb E (Smc) = 10,948 lb ULT. v = 189 PLF ASD SHEAR WALL DESIGN PER: AF&PA SDPWS-2015 ULT. WIND CAPACITY: 1.4 x 0.93 x 460 PLF 1 (2 x 0.6) = 499 PLF ULT. SEISMIC CAPACITY: 1 x 0.93 x 460 PLF / (2 x 0.7) s 305 PLF Holdown Above: NO FLOOR ABOVE ASD C. TOTAL = (floor above) + (this floor) = ASD T. TOTAL w/o DO = (floor above) + (this Floor) = Unfactored C WL = 1515 Ibs Unfactored T WL = 2581 Ibs Unfactored C EQ = 1699 Ibs— - Unfactored T EQ = 1699 Ibs Unfactored C DL = 2850 Ibs Unfactored C LL/SL = 1900 Ibs (ROOF) TV2.010 rrrbulary Area (ROOF) ary width I 0 lnbutary area width 20 total area Tributary Area (NA) Tributary Area (NA) tributary width tributary area total width total area Tributary Area (NA) z Tributary Area (NA) o tributary width a EE�� tributary area a0 total width total area o Tributary Area (NA) Li Tributary Area (NA) z tributary width w tributary area 3 total width total area Height of Shearwall = 9 0 ft Weight of Shearwall = 10 0 Ibs Length of Shearwall - 35 0 ft Tributary width for dead load = 4.0 ft Aspect Ratio OK Length of adjoining wall = 4 5 ft R= 65 LRFD Holdown Design? No no = 2 5 Ductile Anchor Design? No Block Shear Wall USE Seismic controls shearwall design 0 Ibs + 1459 Ibs = 1459 lbs Seismic controls -C3 (ASD eq. 8): 0 Ibs + -486 Ibs = -486 Ibs Wind controls -T1 (ASD eq. 7): NO HOLDOWNS REQUIRED 11 OK FOUNDATION / INTERIOR WALLS: IL UK SEGMENTED WALL Height of Shearwall = 9,0 ft Length of Shearwall = 29 0 fl Aspect Ratio OK Weight of Shearwall = 10.0 Ibs Tributary width for dead load = 4 0 ft Length of adjoining wall = 4.5 ft R= 65 LRFD Holdown Design? No 00 = 2 5 Ductile Anchor Design? No Block Shear Wall USE 1 Seismic controls shearwall design 0 Ibs + 1598 Ibs = 1598 Ibs Seismic controls -C3 (ASD eq. 8): 0 Ibs + -112 Ibs = -112 Ibs Seismic controls -T2 (ASD eq. 10): NO HOLDOWNS REQUIRED OK FOUNDATION I INTERIOR WALLS: UK 9/23/21. 10 43 AM U.S. Seismic Design Maps OSHPD 10406 226th PI SW, Edmonds, WA 98020, USA Latitude, Longitude: 47.7934428,-122.37247 `).i:hth 5" S'vv Date Design Code Reference Document Risk Category Site Class Type Value Ss 1.281 S, 0.45 SMs 1.537 SMi null -See Section 11.4.8 SIDS 1.025 Spi null -See Section 11.4.8 Type Value SDC null -See Section 11.4.8 Fa 1.2 F null -See Section 11.4.8 PGA 0.543 FPGA 1.2 PGAM 0.652 TL 6 SsRT 1.281 SsUH 1.405 SsD 1.989 S 1 RT 0.45 S1UH 0.502 S1D 0.794 PGAd 0.702 CRS 0.912 CR1 0.896 - ,r �VV M R03ev)00i, Icourtt,19 Edmonds Memorial Cemetery Sherwin-WilliaiTta Sunrise of t dlr�onds Paint StOre - Edmonds Goodwill iV1ap data 'Q2021 9/23/2021, 10:41:51 AM ASCE7-16 11 D - Default (See Section 11.4.3) Description MCER ground motion. (for 0.2 second period) MCER ground motion. (for 1.0s period) Site -modified spectral acceleration value Site -modified spectral acceleration value Numeric seismic design value at 0.2 second SA Numeric seismic design value at 1.0 second SA Description Seismic design category Site amplification factor at 0.2 second Site amplification factor at 1.0 second MCEG peak ground acceleration Site amplification factor at PGA Site modified peak ground acceleration Long -period transition period in seconds Probabilistic risk -targeted ground motion. (0.2 second) Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration Factored deterministic acceleration value. (0.2 second) Probabilistic risk -targeted ground motion. (1.0 second) Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration. Factored deterministic acceleration value. (1.0 second) Factored deterministic acceleration value. (Peak Ground Acceleration) Mapped value of the risk coefficient at short periods Mapped value of the risk coefficient at a period of 1 s https://seismicmaps.org 112 9/23/21, 10:43 AM U.S. Seismic Design Maps to' Z DISCLAIMER While the information presented on this website is believed to be correct, SEAOC IQ.5HED and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in this web application should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. SEAOC / OSHPD do not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the seismic data provided by this website. Users or the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by Iatitudeflongitude location in the search results of this website. https://seismicmaps.org 2/2 q-2z-z&,? / // . / - 7 ,--- zC 3 4- Ao J Y�iG1 X �B•�`�/R�r Jvla,h � 3.� l a�(z S ✓ V-0 l /S -2-,;��27 fv�4� ✓y*/�-r'�`30 Zoz N Z? CJGw"' J,7'c�-2 m x l2. 0 Rpo/2` 1��' ,lj��r`'�'� ![,f,` � Fv,-1fC-'�' gar"' Q 1/'fi'� / VGA +•,� j�A/''7 zzs 2, z . 3 3 23 !d � Po,2- lefo yea 6 #,z-- Mo,Z 5 11x9 /"TPF No, 2 /, 2 BM�� P��o ssTS go Zx 6 PTfay IVo, 2 2x o P711FNd, 2 J 34 /(P< 9 7- �flr- A16, Cf /'✓U . G �C. A,i^r cz �m 0 s lq I fo L .• / J ? k 1 -4.G y le lx Cl/i'�J �d''frG•+� I ��� � i�r'": ', .• G7 I l r 12 �G Lr G� s r 318I�vo 16s ion OT / � O 1 30L 12 c .-e-4—f /e Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: / �zf Pnnted' 23 SEP 2021, 1 01PM Wood Beam File- :9371.ec6 Soflwareoopyrr phtEN@RCI+LC, INC. 1�3-Yp2Q, BuiId:12,20.8.24 r f _ ■: DESCRIPTION: BM#1 Long Patio Beam CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 875.0 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb 875.0psi Ebend-xx 1,300.Oksi Fc - Prll 600.0 psi Eminbend - xx 470.0 ksi Wood Species Douglas Fir -Larch Fc - Perp 625.0 psi Wood Grade No.2 Fv 170,0 psi Ft 425.0 psi Density 31.210pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling )0 l rat} 24j S(U 31 [l(0 1$j Lr(U 14)yi Uy3j 6x12 6x12 Span = 12-0 ft Span = 2-0 ft Applied Loads Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.180, Lr = 0,240, S = 0.30 , Tributary Width =1.0 ft, (RF) Load for Span Number 2 Uniform Load : D = 0.180, Lr = 0,240, S = 0.30 , Tributary Width =1.0 ft, (RF) DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations. 7axttnn C Maximum Bending Stress Ratio = 0.826 1 Maximum Shear Stress Ratio = 0.313 :1 Section used for this span 6x12 Section used for this span 6x12 fb: Actual = 831.47psi fv: Actual = 61.21 psi Flo: Allowable = 1,006.25psi Fv: Allowable = 195.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 5.832ft Location of maximum on span = 11,061 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.145 in Ratio = 989>=360 Max Upward Transient Deflection -0.072 in Ratio = 664>=360 Max Downward Total Deflection 0.239 in Ratio = 601 >=180 Max Upward Total Deflection -0.119 in Ratio = 404>=180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FIV C i C r C m C t C L M fb Fb V fv Fv D Only 0.00 0.00 0.00 0,00 Length = 12.0 It 1 0.414 0.157 0.90 1.000 1.00 1.00 1.00 1,00 1.00 3.30 326.23 787.50 1.01 24.02 153.00 Length = 2.0It 2 0.049 0.157 0.90 1,000 1.00 1.00 1,00 1.00 1.00 0.39 38.35 787.50 0.20 24.02 153.00 +D+Lr 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 12.0 it 1 0.668 0,253 1.25 1.000 1.00 1.00 1.00 1.00 1.00 7.38 730.43 1093.75 2.27 53.77 212,50 Length = 2.0 ft 2 0.079 0,253 1.25 1.000 1.00 1,00 1.00 1,00 1.00 0,87 85.86 1093.75 0.46 53.77 212.50 +D+S 1.000 1.00 1.00 1.00 1.00 1.00 0,00 0.00 0.00 0.00 Length = 12.0 ft 1 0.826 0.313 1,15 1.000 1.00 1.00 100 1.00 1.00 8.40 831.47 1006,25 2.58 61.21 195.50 Length = 2.0 ft 2 0,097 0.313 1.15 1,000 1.00 1.00 1.00 1.00 1.00 0.99 97.74 1006.25 0.52 61.21 195.50 +D+0.750Lr 1.000 1.00 1.00 1,00 1.00 1-00 0.00 0.00 0.00 0.00 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 F Project Descr: Wood Beam DESCRIPTION: BM#1 Long Patio Beam Load Combination Max Stress Ratios Segment Length Span # M V Length = 12.0 ft 1 0.575 0.218 Length = 2.0 It 2 0.068 0,218 +D+0.750S Length = 12.0 ft 1 0.701 0.266 Length = 2.0 ft 2 0.082 0.266 +0.60D Length = 12.0 ft 1 0.140 0.053 Length = 2.0 ft 2 0.016 0.053 Overall Maximum Deflections Load Combination Span +D+S 1 2 Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+Lr +D+S +0+0.750Lr +D+0.750S +0.60D Lr Only S Only Cd CF/V Ci Cr Cm C t CL 1.25 1.000 1.00 1.00 1.00 1.00 1.00 125 1.000 1.00 1.00 1.00 1.00 1.00 1.000 1,00 1.00 1.00 1.00 1.00 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1.15 1.000 1.00 1.00 1.00 1.00 1.00 1.000 1.00 1.00 1.00 1.00 1.00 1.60 1.000 1.00 1.00 1.00 1.00 1.00 1.60 1.000 1.00 1.00 1.00 1.00 1.00 Max. " " Defl Location in Span Load Combination 0.2394 5.966 0.0000 5.966 +D+S Support notation : Far left is #1 Support 1 Support 2 Support 3 2.880 4.032 1.750 2.450 1.130 1.582 2.530 3.542 2.880 4.032 2.180 3.052 2.442 3,419 0.678 0.949 1.400 1,960 1.750 2.450 Printed: 23 SEP 2021, 1 01PM File: 9371.ec6 Software.cMiright ENERCALC, INC. W3.2020, Build:12.20.8.24 ;" I iiwi6 611 A� A Moment Values M fb F'b 6.36 629.38 1093.75 0.75 73,98 1093,75 0.00 7.12 705.16 1006,25 0.84 82.89 1006.25 0.00 1.98 195.74 1400.00 0.23 23.01 1400.00 Shear Values V tv F'v 1,95 46.34 212.50 0.39 46.34 212.50 0.00 0.00 0.00 2.19 51.91 195.50 0.44 51.91 195.50 0.00 0.00 0.00 0.61 14.41 272.00 0.12 14.41 272.00 Max. "+" DeA Location in Span 0.0000 0.000 -0.1186 2.000 Values in KIPS Wood Beam r:r •fr: -- DESCRIPTION: BM#2: Short Patio Beam (indeterminate) Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: 11 Printed: 23 SEP 2021. 3:51PIv1 File: 9371.eC6 Software aopyright L•NEK ALC, INC. 1983.2020, Build:12.20.8.24 CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 875.0 psi Load Combination ASCE 7-16 Fb 875.0 psi Fc Prll 600.0 psi Wood Species Douglas Fir -Larch Fc Perp 625.0 psi Wood Grade No.2 Fv 170.0 psi Ft 425.0 psi Beam Bracing Beam is Fully Braced against lateral -torsional buckling 0(0 18) Lr(024) SO 3) 6x12 E Modulus of Elasticity Ebend- xx 1,300.0 ksi Eminbend - xx 470.0 ksi Density 31.210 pcf DW 18) Lr(0.24) 13(0 3) 6x12 Span =9.Oft Span =20ft Applied Loads Service loads entered. Load Factors will be applied for calculations Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.180, Lr = 0.240, S = 0.30 , Tributary Width =1.0 ft, (RF) Load for Span Number 2 Uniform Load : D = 0,180, Lr= 0.240, S = 0.30 , Tributary Width =1.0 ft, (RF) DESIGN SUMMARY = _ • Maximum Bending Stress Ratio = 0.4441 Maximum Shear Stress Ratio = 0.226 : 1 Section used for this span 6x12 Section used for this span 6x12 fb: Actual = 447.15psi fv: Actual = 44.10 psi Fb: Allowable = 1,006.25psi Fv: Allowable = 195.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 4.274ft Location of maximum on span - 8.045ft Span # where maximum occurs = Span # 1 Span # where maximum occurs - Span # 1 Maximum Deflection Max Downward Transient Deflection 0.043 in Ratio = 2483 >=360 Max Upward Transient Deflection -0.027 in Ratio = 1794>=360 Max Downward Total Deflection 0.072 in Ratio = 1508 >=180 Max Upward Total Deflection -0.044 in Ratio = 1090 >=180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FfV C i C r C m C t C L M fb Fb V tv Fv D Only 0.00 0,00 0.00 0,00 Length = 9.0 ft 1 0.223 0,113 0.90 1.000 1.00 1.00 1.00 1.00 1.00 1,77 175.44 787.50 0.73 17,30 153.00 Length = 2.0 ft 2 0.049 0.113 0.90 1.000 1,00 1.00 1.00 1,00 1.00 0.39 38.35 787.50 0.20 17.30 153.00 +D+Lr 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0,00 0.00 Ho Length = 9.0 ft 1 0,359 0.182 1,25 1.000 1.00 1.00 1.00 1.00 1.00 397 392,81 1093.75 1.63 38.74 212.50 Length = 2.0 ft 2 0-079 0.182 1.25 1,000 1.00 1.00 1.00 1.00 1.00 087 85.86 1093.75 0,46 38.74 212.50 +D+S 1,000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0,00 0.00 Length = 9.0 ft 1 0.444 0.226 1.15 1,000 1.00 1.00 1.00 1.00 100 4.52 44715 1006.25 1.86 44,10 195.50 Length = 2.0 ft 2 0.097 0.226 1.15 1.000 1.00 1,00 100 1.00 1,00 099 97.74 1006.25 0.52 44.10 195.50 +D+0.750Lr 1.000 1,00 1.00 1.00 1.00 1,00 0.00 0.00 0.00 0,00 Project Title- Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: r Printed 23 SEP 2021, 3:51PM Wood Beam File:9371.ec6 Software ENERCALC, INC. 1963-2020, Build:12.20.8.24 DESCRIPTION: BM#2: Short Patio Beam (indeterminate) r Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i C r C m C t C L M fb F'b V iv F'v Length = 9.0 ft 1 0.309 0.157 1,25 1.000 1.00 1.00 1,00 1.00 1,00 3.42 338.46 1093.75 1.41 33.38 212.50 Length = 2.0 ft 2 0.068 0.157 1.25 1.000 1.00 1.00 1.00 1.00 1.00 0,75 73.98 1093.75 0.39 33.38 212.50 +0+0.750S 1.000 U0 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 9.0 It 1 0.377 0,191 1,15 1.000 1.00 1.00 1.00 1.00 1.00 183 379.22 1006.25 1.58 37.40 195.50 Length = 2.0 ft 2 0.082 0.191 1.15 1.000 1,00 1.00 1,00 1.00 1.00 0.84 82.89 1006.25 0.44 37.40 195.50 +0.60D 1.000 1.00 1.00 1,00 1.00 1.00 0,00 0.00 0.00 0.00 Length = 9.0 ft 1 0.075 0.038 1.60 1.000 1.00 1.00 1.00 100 1.00 1.06 105.26 1400.00 0.44 10.38 272.00 Length = 2.0 ft 2 0,016 0.038 1.60 1.000 1.00 1.00 1.00 1.00 1.00 0.23 23.01 1400.00 0.12 10.38 272.00 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination Max. "+" Defl Location in Span +D+S 1 0.0716 4.425 0,0000 1000 2 0.0000 4.425 +D+S -0,0440 2.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 2.112 3,319 Overall MINimum 1.283 2.017 D Only 0.829 1.302 +D+Lr 1.855 2.915 +D+S 2.112 3.319 +D+0.750Lr 1.599 2.512 +D+0.750S 1,791 2.815 +0.60D 0,497 0.781 Lr Only 1,027 1.613 S Only 1.283 2.017 Wood Beam DESCRIPTION: BM#3: Rear Side Window HDR CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed: 23 SEP 2021, 1:06PM File:9371.ec6 r` Software copynphlENERCALC.INC. 1%3-2020,Build: 12.20.8.24 s, Analysis Method: Allowable Stress Design Fb+ Load Combination ASCE 7-16 Fb - Fc - Prll Wood Species ; Hem -Fir Fc - Perp Wood Grade : No.2 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling µ Dj I 135) Lr(0-18) S(0 225) 4x6 Span =50ft Applied Loads Beam self weight calculated and added to loads Uniform Load : D = 0,1350, Lr = 0.180, S = 0.2250 , Tributary Width =1.0 ft, (RF) DESIGN SUMMARY 850.0 psi 850.0 psi 1, 300.0 psi 405.0 psi 150.0 psi 525.0 psi E : Modulus of Elasticity Ebend-xx 1,300.Oksi Eminbend - xx 470.Oksi Density 26.840 pcf Service loads entered Load Factors will be applied for calculations Maximum Bending Stress Ratio = 0.608 1 Maximum Shear Stress Ratio Section used for this span 4x6 Section used for this span fb: Actual = 772.68 psi fv: Actual Fb: Allowable = 1,270.75psi Fv: Allowable Load Combination +D+S Load Combination Location of maximum on span = 2.500ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0,050 in Ratio = 1189>=360 Max Upward Transient Deflection 0,000 in Ratio = 0 <360 Max Downward Total Deflection 0.082 in Ratio = 735>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C FN C i Cr C m C t C L D Only Length = 5.0 ft 1 0.296 0,163 0.90 1.300 1.00 1.00 1.00 1.00 1.00 +D+Lr 1.300 1.00 1.00 1.00 1.00 1,00 Length = 5,0 ft 1 0.490 0.271 1.25 1.300 1.00 1.00 1.00 1.00 1,00 +D+S 1.300 1.00 1.00 1.00 1.00 1-00 Length = 5.0 ft 1 0.608 0.336 1.15 1.300 1.00 1.00 1.00 1.00 1.00 +D+0.750Lr 1,300 1.00 1.00 1.00 1.00 1.00 Length = 5.0 ft 1 0.421 0.232 1.25 1.300 1.00 1.00 1.00 1.00 1.00 +D+0,750S 1.300 1,00 1.00 1.00 1.00 1.00 Length = 5.0 ft 1 0.514 0,284 1.15 1.300 1,00 1,00 1.00 1.00 1.00 +0.60D 1.300 1.00 1.00 1.00 1.00 1-00 Length = 5.0 ft 1 0.100 0.055 1.60 1.300 1.00 1.00 1.00 1.00 1.00 3aninn C = 0,336 : 1 4x6 = 57.90 psi 172,50 psi +D+S 0.000 ft Span # 1 Moment Values M fb F'b 0.00 0.43 294.52 994.50 0.00 1.00 677.05 1381.25 0.00 1.14 772.68 1270.75 0.00 0.85 581.41 1381.25 0.00 0.96 653.14 1270.75 0.00 0.26 176.71 1768.00 Shear Values V fv F'v 0.00 0.00 0.00 0.28 22.07 135.00 0.00 0-00 0.00 0.65 50.74 187.50 0.00 0.00 0.00 0.74 57.90 172.50 0.00 0.00 0.00 0.56 43.57 187.50 0.00 0.00 0.00 0.63 48.95 172.50 0.00 0.00 0.00 0.17 1124 240.00 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed 23 SEP 2021, 1 06PM Wood Beam t le:9371.ec6 Softwarecopy ht ENERCALC.INC, M-2020. Build:12,20'8.24 DESCRIPTION: BM#3: Rear Side Window HDR Overall Maximum Deflections Load Combination Span Max. '-"Dell Location in Span Load Combination Max. "+" Dell Location in Span +D+S 1 0.0815 2.518 0,0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.909 0.909 Overall MINimum 0,563 0.563 D Only 0.346 0.346 +D+Lr 0.796 0.796 +D+S 0.909 0 909 +D+0.750Lr 0.684 0.684 +D+0.750S 0,768 0,768 +0.60D 0,208 0.208 Lr Only 0.450 0.450 S Only 0.563 0.563 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: ;3 r Printed. 23 SLP 2021, 1 53PM Wood Beam File: .ec6 Software oopygiptll ENERCALC, INC. 1983-2020, Build: 12.212,20.8.24 DESCRIPTION: BM#4.0: Interior Overframing Beam (2 Short Beams) CODE REFERENCES Calculations per NDS 2016, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 850.0 psi E : Modulus of Elasticity Load Combination ASCE7-16 Fb- 850.0psi Ebend-xx 1,300.Oksi Fc - Prll 1,300.0 psi Eminbend - xx 470.Oksi Wood Species : Hem -Fir Fc - Perp 405.0 psi Wood Grade : No.2 Fv 150.0 psi Ft 525.0psi Density 26.840pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0 023) Lr(0.03) 3(0,038) D(0 225.) Lr(0 .3) .3(0 375) 4x10 Span = 6 50 ft Applied Loads Service loads entered. Load Factors will be applied for calculations Beam self weight calculated and added to loads Uniform Load : D = 0,2250, Lr = 0,30, S = 0.3750 , Tributary Width = 1.0 ft, (RF) Uniform Load : D = 0.0230, Lr = 0.030, S = 0,0380 , Tributary Width =1.0 ft, (RF) DESIGN SUMMARY a • Maximum Bending Stress Ratio = 0.722 1 Maximum Shear Stress Ratio - 0.446 :1 Section used for this span 4x10 Section used for this span 4x10 fb: Actual = 846.97psi fv: Actual - 76.98 psi Flo: Allowable = 1,173.00psi Fv: Allowable = 172.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 3.250ft Location of maximum on span = 5.741 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.056 in Ratio = 1402>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.090 in Ratio = 868>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr C m C t C L M lb F'b V (v F'v D Only 0.00 0.00 0,00 0.00 Length = 6.50 ft 1 0.351 0.217 0.90 1.200 1.00 100 1.00 1.00 1,00 1.34 322.56 918,00 0.63 29,32 135.00 +O+Lr 1.200 1.00 1.00 1.00 1.00 1,00 0.00 0.00 0.00 0.00 Length = 6.50 ft 1 0.582 0,359 1.25 1.200 1.00 1.00 1.00 1.00 1.00 3.08 741.58 1275,00 1.45 67.40 187.50 +D+S 1,200 1.00 1,00 1.00 1.00 1.00 0.00 0,00 0.00 0.00 Length = 6.50 It 1 0.722 0,446 1.15 1,200 1.00 1.00 1.00 1.00 1.00 3.52 846.97 1173.00 1.66 76.98 172.50 +D+0,750Lr 1.200 1.00 1.00 1.00 1.00 1.00 0.00 000 0.00 0.00 Length = 6.50 ft 1 0.499 0.309 1,25 1.200 1.00 1.00 1.00 1,00 1.00 2.65 636.82 1275.00 1,25 57.88 187.50 +0+0.750S 1.200 1,00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 It 1 0.610 0.377 1.15 1.200 1.00 1.00 1.00 1.00 1.00 2.98 715.86 1173.00 140 65.06 172.50 +0.60D 1,200 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.50 It 1 0.119 0.073 1.60 1.200 1.00 1,00 1.00 1.00 1.00 0.80 193.54 1632.00 0.38 17.59 240.00 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: r Printed: 23 SEP 2021, 1:53PM File: 9371.ec6 Wood Beam Software ht ENERCALC, INC 19B3-MAJ, Bu11d:12.20.8.24 DESCRIPTION: BM#4.0: Interior Overframing Beam (2 Short Beams) Overall Maximum Deflections Load Combination Span +D+S 1 Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+Lr +D+S +D+0.750Lr +D+0.750S +0.60D Lr Only S Only Max. "-" Dell Location in Span Load Combination 0.0898 3.274 Support notation : Far left is #1 Support 1 Support 2 2.168 2.168 1.342 1.342 0.826 0.826 1.898 1.898 2.168 2.168 1.630 1,630 1.832 1.832 0.495 0.495 1.073 1.073 1,342 1.342 Max. "+" Dell Location in Span 0.0000 0.000 Values in KIPS Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed 23 SEP 2021, 1 53PM Wood Beam File :12.2 .ec6 SoilwarecopyrrghtENERCALC, INC. 1983-2020, BuiId:12.20.8.24 '.... r IT DESCRIPTION: BM#4.1: Interior Overframing Beam (1 Long Beam) CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 2900 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 2900 psi Ebend- xx 2000 ksi Fc - Prll 2900 psi Eminbend - xx 1016.535 ksi Wood Species : iLevel Truss Joist Fc - Perp 750 psi Wood Grade : Parallam PSL 2.0E Fv 290 psi Ft 2025 psi Density 45.07pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0 023) I_r(0 03) S(U 038) 17(0225)_Lrl01� Sj0 3i5j Lc &TIllifillp Span = 13 50 ft Applied Loads Beam self weight calculated and added to loads Uniform Load D = 0.2250, Lr = 0,30, S = 0.3750 , Tributary Width =1.0 ft, (RF) Uniform Load D = 0.0230, Lr = 0,030, S = 0.0380 , Tributary Width = 1.0 ft, (RF) DESIGN SUMMARY A Service loads entered Load Factors will be applied for calculations. Maximum Bending Stress Ratio = 0.74a 1 Maximum Shear Stress Ratio Section used for this span 3.5x11.25 Section used for this span fb: Actual = 2,493.22psi fv: Actual Fb: Allowable = 3,335.00psi Fv: Allowable Load Combination +D+S Load Combination Location of maximum on span = 6.750ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.374 in Ratio = 433 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.609 in Ratio = 265 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C F/V C i Cr D Only Length=13.451 ft 1 0.369 0,221 0.90 1.000 1.00 1.00 Length = 0.04927 ft 1 0.005 0.221 0.90 1.000 1.00 1.00 +D+Lr 1.000 1,00 1.00 Length = 13.451 ft 1 0.603 0.361 1.25 1,000 1.00 1.00 Length = 0.04927 ft 1 0,009 0.361 1.25 1.000 1.00 1.00 +D+S 1.000 1,00 1,00 Length = 13.451 ft 1 0.748 0.447 1,15 1,000 1.00 1.00 Length = 0.04927 ft 1 0,011 0.447 1.15 1.000 1,00 1.00 +D+0,750Lr 1.000 1,00 1.00 Length = 13.451 ft 1 0.519 0.310 1,25 1.000 1.00 1,00 Length = 0,04927 ft 1 0.008 0.310 1.25 1.000 1.00 1,00 .: ■ 0.447 :1 3.5x11.25 149.13 psi 333.50 psi +D+S 0.000 ft - Span # 1 Moment Values Shear Values C m C t C L M fb Fb V fv Fv 0.00 0.00 0.00 0.00 1.00 1,00 1.00 5.93 963,94 2610.00 1.51 57.66 261.00 1.00 1.00 1.00 0,09 14.02 2610.00 1.51 57,66 261.00 1,00 1.00 1.00 0.00 0.00 0,00 0.00 1.00 1.00 1.00 13.45 2,185.88 3625.00 3.43 130.75 362.50 1.00 1.00 1.00 0.20 31.79 3625.00 3.43 130.75 362.50 1.00 1,00 1.00 0.00 0.00 0.00 0.00 1.00 1,00 1.00 15.34 2,493,22 3335.00 3.91 149.13 333.50 1,00 1.00 1.00 0.22 36.26 3335.00 3.91 149.13 333.50 1.00 1.00 1.00 0,00 0.00 0.00 0.00 1.00 1.00 1.00 11,57 1,880.40 3625.00 2.95 112.47 362.50 1.00 1.00 1.00 0.17 27.35 3625.00 2.95 112.47 362.50 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: , '� �-- Printed• 23 SEP 2021, 11:53PM Wood Beam File: 9371.ec6 50dware xpyr,9hi ENERCALC. INC 1983.2020, 8uiId:1220A24 DESCRIPTION: BM#4,1; Interior Overframing Beam (1 Long Beam) Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FIV C i C r C m C t C L M fb F'b V Iv F'v -+0+ 750S 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 13.451 It 1 0.633 0,379 1,15 1.000 1.00 1,00 1.00 1.00 1,00 12,99 2,110.90 3335.00 3.31 126.26 333.50 Length = 0.04927 ft 1 0.009 0 379 1.15 1.000 1.00 100 100 1.00 1,00 0.19 30.70 3335.00 3.31 12626 333.50 +0.60D 1.000 1.00 1,00 1.00 1.00 100 0.00 0.00 0.00 0.00 Length = 13.451 ft 1 0,125 0.075 1.60 1.000 1.00 1.00 1,00 1.00 1.00 356 578.37 4640.00 0.91 34.59 464.00 Length = 0,04927 It 1 0.002 0.075 1.60 1.000 1.00 100 1.00 1.00 1.00 005 8,41 4640.00 0.91 3459 464.00 Overall Maximum Deflections Load Combination Span Max. " " Defl Location in Span Load Combination Max. "+' Defl Location in Span +D+S 1 0.6094 6.799 0.0000 0,000 Vertical Reactions Support notation Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 4,545 4.545 Overall MINimum 2,788 2,788 D Only 1.757 1.757 +D+Lr 3.985 3.985 +D+S 4.545 4.545 +Di0.750Lr 3.428 3.428 +D+0.750S 3.848 3,848 +0.60D 1,054 1,054 Lr Only 2.228 2.228 S Only 2.788 2,788 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr:` Printed: 23 SEP 2021. 1:57PM Wood Beam1•IIe: 9371.ee _ Spilware cnpyagh! ENFRf.ALC. iHG. 1963-247,U. $uild;12.21}.$,24 1: i' ,. 1; DESCRIPTION: BM#4.2: Interior Overframing Beam (1 Long Beam) CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + Load Combination ASCE 7-16 Fb - Fc - Prll Wood Species : iLevel Truss Joist Fc - Perp Wood Grade : Parallam PSL 2.0E Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 0(0 023) Lr(0 03) S(0.03£3) D(0 225) Lr(U.3j S(0 375) 5 25x9 5 w Span = 13.50 ft Applied Loads Beam self weight calculated and added to loads Uniform Load : D = 0.2250, Lr = 0.30, S = 0.3750 , Tributary Width =1.0 ft, (RF) Uniform Load : D = 0.0230, Lr = 0.030, S. = 0.0380 , Tributary Width =1.0 ft, (RF) DESIGN SUMMARY 2,900.0 psi E Modulus of Elasticity 2,900.0psi Ebend-xx 2,000.Oksi 2,900.0 psi Eminbend - xx 1,016.54ksi 750.0 psi 290.0 psi 2,025.0 psi Density 45.070pcf Service loads entered. Load Factors will be applied for calculations Maximum Bending Stress Ratio = 0.7021 Maximum Shear Stress Ratio Section used for this span 5.25x9.5 Section used for this span fb: Actual = 2,342,30psi fv: Actual Fb: Allowable = 3,335.00psi Fv: Allowable Load Combination +D+S Load Combination Location of maximum on span = 6.750ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.414 in Ratio = 391 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.678 in Ratio = 238 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C FN C i Cr D Only Length=13.451 ft 1 0.350 0.181 0.90 1.000 1.00 1.00 Length = 0.04927 It 1 0.005 0.181 0.90 1.000 1.00 1.00 +D+Lr 1.000 1.00 1.00 Length = 13.451 It 1 0.567 0,294 1.25 1,000 1.00 1.00 Length = 0.04927 ft 1 0.008 0.294 1.25 1.000 1,00 1.00 +D+S 1.000 1.00 1.00 Length = 13.451 ft 1 0.702 0.364 1,15 1,000 1.00 1.00 Length = 0.04927 It 1 0.010 0,364 1.15 1.000 1.00 1.00 +D+0.750Lr 1.000 1.00 1.00 Length = 13.451 ft 1 0,488 0.253 1.25 1,000 1.00 1,00 Length = 0.04927 ft 1 0.007 0.253 1.25 1.000 1.00 1.00 �31;Mlflj a 0.364 :1 5.25x9.5 121.32 psi = 333.50 psi +D+S = 0.000 ft Span # 1 Moment Values Shear Values C m C t C L M fb Fb V fv Fv 000 0.00 0.00 0.00 1.00 1.00 1,00 6.01 912.57 2610.00 1.57 47.26 261.00 1,00 1.00 1.00 0.09 13,27 2610.00 1.57 47.26 261.00 1.00 1.00 1.00 0.00 0.00 0.00 0,00 1.00 1.00 1.00 13,52 2,054.97 3625.00 3.54 106.43 362.50 1.00 1.00 1.00 0.20 29.89 3625.00 3.54 106.43 362,50 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 15.41 2,342.30 3335.00 4.03 121.32 333.50 1.00 1.00 1.00 0.22 34.07 3335.00 4.03 121.32 333.50 1,00 1,00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 11,64 1.769,37 3625.00 3.05 91.64 362.50 1,00 1.00 1.00 0.17 25.74 3625.00 3.05 91.64 362.50 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: n Printed 23 SEP 2021. 1 57PM Wood Beam File:9371,ec6 re Suilwacopynghl ENERCALC. !NC. t993.242a, BuiId:12.20.8.24 DESCRIPTION: BM#4.2: Interior Overframing Beam (1 Long Beam) Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FM C i C r C m C t C L M fb F'b V fv F'v +D+0.750S 1.000 1,00 1.00 1.00 1.00 1.00 0.00 0,00 0.00 0.00 Length = 13.451 ft 1 0.595 0.308 115 1.000 1.00 1.00 1.00 1.00 1.00 13.06 1,984.87 3335.00 3.42 102.80 333.50 Length = 0.04927 It 1 0.009 0.308 1.15 1.000 1.00 1.00 1.00 1.00 1.00 0.19 28.87 3335.00 3.42 102.80 333.50 +0.60D 1,000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0,00 0.00 Length = 13.451 ft 1 0.118 0,061 1.60 1.000 1.00 1.00 1.00 1.00 1.00 3,60 547,54 4640.00 0.94 28,36 464.00 Length = 0.04927 ft 1 0.002 H61 1.60 1.000 1.00 1.00 1.00 1.00 1.00 005 7.96 4640.00 0.94 28.36 464.00 Overall Maximum Deflections Load Combination Span Max. " " Defl Location in Span Load Combination Max. "+" DeFl Location in Span +D+S 1 0.6780 6.799 0.0000 0.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 4.567 4.567 Overall MINimum 2.788 2.788 D Only 1.779 1.779 +D+Lr 4.007 4.007 +D+S 4.567 4.567 +0+0.750Lr 3.450 3.450 +D+0.750S 3.870 3.870 +0.60D 1.068 1.068 Lr Only 2.228 2.228 S Only 2.788 2.768 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed: 23 SEP 2021, 1:09PM Wood Beam File-9371.ec6 SolPnare coppignt LNERCALC INC. 1883.2020. Build':12,20.8 24 DESCRIPTION: BM#5: Rear Window & SLDR HDRS CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 850.0 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb • 850.0 psi Ebend-xx 1,300.Oksi Fc - Prll 1,300.0 psi Eminbend - xx 470.Oksi Wood Species ; Hem -Fir Fc - Perp 405.0 psi Wood Grade : No.2 Fv 150.0 psi Ft 525.0psi Density 26.840pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling 0(0 06) Lr(0 08) 3(0 l ) 4x6 Span = 6.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load : D = 0.060, Lr = 0.080, S = 0.10 , Tributary Width =1.0 It, (RF) DESIGN SUMMARY _ : • Maximum Bending Stress Ratio = 0.3941 Maximum Shear Stress Ratio - 0.189 : 1 Section used for this span 4x6 Section used for this span 4x6 fb: Actual = 500.61 psi fv: Actual = 32.66 psi Fb: Allowable = 1,270.75psi Fv: Allowable = 172.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 3,000ft Location of maximum on span = 0.000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.046 in Ratio = 1548 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.076 in Ratio = 946>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C NV C i C r C m C t C L M fb Fb V tv Fv D Only 0.00 0.00 0.00 0.00 Length = 6.0 ft 1 0.196 0.094 0.90 1.300 1.00 1.00 1,00 1.00 1,00 0.29 194.59 994.50 0.16 12.69 135.00 +D+Lr 1,300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.0 It 1 0.318 0.153 1.25 1.300 1.00 1.00 1,00 1.00 1.00 0,65 439,41 1381,25 0.37 28.67 187.50 +D+S 1,300 1.00 1.00 1.00 1.00 1.00 0,00 0.00 0.00 0.00 Length = 6.0 It 1 0.394 0.189 1.15 1.300 100 1.00 1,00 100 1.00 0.74 500.61 1270.75 0.42 32.66 172.50 +0+0.750Lr 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0,00 Length = 6.0 ft 1 0.274 0.132 1.25 1.300 1.00 1.00 1.00 1,00 1.00 0.56 378,21 1381.25 0.32 24.67 18T50 +D+0.750S 1.300 1.00 1.00 1.00 1,00 1.00 0.00 0.00 0.00 0,00 Length = 6.0 ft 1 0,334 0.160 1.15 1.300 1.00 1.00 1.00 1.00 1.00 0.62 424.11 1270.75 0.36 27.67 172.50 +0.60D 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 6.0 ft 1 0.066 0,032 1.60 1,300 1.00 1.00 1.00 1.00 1.00 0.17 116.76 1768.00 0.10 7.62 240.00 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed: 23 SEP 2021, 1:09PM Wood Beam File, 92. .ec6 59ffivrue �ropyiiyl�! ENERCALC, ING 198&2020, BuiId:120.(3.24 DESCRIPTION: BM#5: Rear Window & SLDR HDRS Overall Maximum Deflections Load Combination Span +D+S 1 Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+Lr +D+S +D+0.750Lr +D+0.750S +0.60D Lr Only S Only Max. "" Dell Location in Span Load Combination 0.0761 3.022 Support notation : Far left is #1 Support Support 0.491 0,491 0.300 0.300 0.191 0,191 0,431 0.431 0.491 0.491 0,371 0.371 0.416 0,416 0,114 0.114 0.240 0.240 0.300 0.300 Max. "+" Defl Location in Span 0.0000 0,000 Values in KIPS Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed'. 23 SEP 2021, 1 10PM Wood Beam Fud937,ec6 Software I ENEf2CALC, INC. 1983.2020. Build:12.20.8.24 DESCRIPTION: BM#6: Patio Beam CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method : Allowable Stress Design Fb + 850 psi E: Modulus of Elasticity Load Combination ASCE 7-16 Fb - 850 psi Ebend-xx 1300ksi Fc - Prll 1300 ps[ Eminbend - xx 470 ksi Wood Species Hem -Fir Fc - Perp 405 psi Wood Grade No.2 Fv 150 psi Ft 525 psi Density 26,84pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0.072) L(0.36) S(0 15) 48 Span = 5 0 ft Applied Loads Beam self weight calculated and added to loads Uniform Load : D = 0.0720, L = 0.360, S = 0.150 , Tributary Width =1.0 ft, (DK) DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations Maximum Bending Stress Ratio = 0.604 1 Maximum Shear Stress Ratio Section used for this span 4x8 Section used for this span fb: Actual = 534.14psi fv: Actual Fb: Allowable = 884.00psi Fv: Allowable Load Combination +D+L Load Combination Location of maximum on span = 2.500ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.037 in Ratio = 1617>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.047 in Ratio = 1267>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C FN C i C r C m C t C L D Only Length = 5.0 ft 1 0.118 0,080 0.90 1.300 0.80 1.00 1.00 1.00 1.00 +D+L 1.300 0.80 1,00 1.00 1.00 1.00 Length = 5.0 ft 1 0.604 0.408 1.00 1,300 0.80 1,00 1.00 1.00 1.00 +D+S 1.300 0.80 1.00 1.00 1.00 1,00 Length = 5.0 ft 1 0.273 0.184 1.15 1.300 0.80 1.00 1.00 1.00 1,00 +D+0.750L 1.300 0,80 1.00 1.00 1.00 1.00 Length = 5.0 ft 1 0.384 0,259 1,25 1.300 0.80 1.00 1.00 1.00 1,00 +D+0.750L+0.750S 1,300 0.80 1.00 1.00 1.00 1.00 Length = 5.0 ft 1 0.552 0.373 1.15 1.300 0.80 1.00 1.00 1.00 1.00 +0.60D 1,300 0.80 1.00 1.00 1.00 1,00 Length = 5.0 ft 1 0.040 0.027 1.60 1,300 0.80 1.00 1.00 1.00 1.00 o = , a :I = 0.408 : 1 4x8 48.99 psi 120.00 psi +D+L - 0.000 ft Span # 1 Moment Values M lb Pb 0.00 0.24 93.84 795.60 0.00 1,36 534.14 884,00 0,00 0.71 277.30 1016.60 0.00 1.08 424,06 1105.00 0.00 1.44 561.65 1016.60 0.00 0.14 56.31 1414.40 Shear Values V tv F'v 0.00 0.00 0.00 0.15 8.61 108.00 0.00 0,00 0.00 0.83 48.99 120.00 000 0.00 0.00 0.43 25.44 138.00 0.00 0,00 0.00 0,66 MAO 150.00 000 0,00 0.00 087 51.52 138.00 000 Ho 0.00 0,09 5.16 192.00 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: r Printed: 23 SEP 2021, 1:10PM Wood Beam File: 9371.ec6 Software copyhi ENERCALC, INC.1983-2020, Build:12.20.8,24 DESCRIPTION: BII Patio Beam Overall Maximum Deflections Load Combination Span +D+0.750L+0.750S 1 Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+L +D+S +D+0.750L +D+0.750L+0.750S +0.60D L Only S Only Max. " " Defl Location in Span Load Combination 0.0473 2.518 Support notation : Far left is #1 Support 1 Support 2 1.148 1.148 0.375 0.375 0,192 0.192 1.092 1.092 0.567 0.567 0.867 0.867 1.148 1.148 0.115 0,115 0.900 0.900 0.375 0.375 Max. "+" Defl Location in Span 0.0000 0,000 Values in KIPS Wood Beam DESCRIPTION: BM#7: Patio Joists CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + Load Combination ASCE 7-16 Fb - Fc Prll Wood Species : Hem -Fir Fc Perp Wood Grade : No.2 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling 0(0 016) I_(0 08) S(0 03333) 2x6 Span == 6.0 ft Applied Loads Beam self weight calculated and added to loads Uniform Load : D = 0,0160, L = 0,080, S = 0.03333 , Tributary Width =1.0 ft, (DK) DESIGN SUMMARY Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr �� r Printed, 23 SEP 2021, 1:12PM GIs 9371.ec6 Software cMngIR ENERCALC, INC 1%3.2026. Build:12.20.8,24 850.0 psi E : Modulus of Elasticity 850.0 psi Ebend- xx 1,300.Oksi 1,300.0 psi Eminbend - xx 470.Oksi 405.0 psi 150.0 psi 525.0 psi Density 26.840pcf Repetitive Member Stress Increase k Service loads entered. Load Factors will be applied for calculations. Maximum Bending Stress Ratio = 0.6851 Maximum Shear Stress Ratio Section used for this span 2x6 Section used for this span fb: Actual = 696.47psi fv: Actual Fb: Allowable = 1,016.60psi Fv: Allowable Load Combination +D+L Load Combination Location of maximum on span = 3,000ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.091 in Ratio = 788 >=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.117 in Ratio = 614>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C FN C i Cr D Only Length = 6.0 ft 1 0.137 0.076 0.90 1,300 0.80 1.15 +D+L 1,300 0.80 1,15 Length = 6.0 ft 1 0.685 0,379 1.00 1,300 0,80 1,15 +D+S 1.300 0.80 1,15 Length = 6.0 ft 1 0.311 0,172 1.15 1,300 0.80 1.15 +0+0.750L 1.300 0.80 1.15 Length = 6.0 It 1 0.436 0.241 1,25 1.300 0.80 1.15 +D+0.750L+0.750S 1,300 0.80 1.15 Length = 6 0 ft 1 0,626 0.346 1.15 1.300 0,80 1,15 +0.60D 1.300 0,80 1.15 Length = 6.0 ft 1 0.046 0.026 1.60 1,300 0.80 1.15 = 0.379 : 1 2x6 45.44 psi 120.00 psi +D+L 0.000 ft Span # 1 Moment Values Shear Values C m C t C L M fb Fb V fv Fv 0.00 0.00 0.00 0.00 1.00 1.00 1.00 0.08 125.23 914.94 0.04 8,17 108.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1,00 1.00 044 696.47 1016,60 0.25 45A4 120.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 0.23 363.22 1169.09 0.13 23.70 138.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 1.00 0.35 553.66 1270.75 0.20 36.12 150.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 1.00 1.00 100 0.46 732.15 1169,09 0.26 47.76 138,00 1.00 1.00 1,00 0.00 0.00 0.00 0.00 1.00 1.00 1,00 0.05 75.14 1626.56 0.03 4.90 192.00 Wood Beam DESCRIPTION: BM#7: Patio Joists Overall Maximum Deflections Load Combination Span +D+0.750L+0,750S 1 Vertical Reactions Load Combination Overall MAXimum Overall MINimum D Only +D+L +D+S +D+0.750L +D+0.750L+0.750S +0.60D L Only S Only Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Z0,2 Printed: 23 SEP 2021. 1:12PM rile:93-71.eC6 Soflwarecopyrighi iNr1iCALC. INC 19n2020. Build:12.20.8.24 - - - - :�. , Max.'-" Deft Location in Span Load Combination 0.1171 3.022 Support notation : Far left is #1 Support 1 Support 2 0.308 0.308 0.100 0.100 0.053 0.053 0.293 0.293 0.153 0.153 0.233 0.233 0.308 0.308 0.032 0.032 0.240 0.240 0.100 0.100 Max. "+" Defl Location in Span 0.0000 0.000 Values in KIPS Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Wood Beam Printed: 23 SEP 2021, 1 14PM File: 9371.ec5 ENERCALC, INC.1983-2020, Build: 12,20.8.24 DESCRIPTION: BM#8: Exterior Patio Beam CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 850.0 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 850.0 psi Ebend- xx 1,300.Oksi Fc - Prll 1,300,0 psi Eminbend - xx 470.0 ksi Wood Species Hem -Fir Fc - Perp 405.0 psi Wood Grade No.2 Fv 150.0 psi Ft 525.0 psi Density 26.840pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0 036) Lr(0.18) L(0.075). 48 Span =5.0ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load : D = 0.0360, Lr = 0.180, L = 0.0750 , Tributary Width =1.0 ft, (DK) DESIGN SUMMARY ■ Maximum Bending Stress Ratio = 0.2571 Maximum Shear Stress Ratio = 0.173 : 1 Section used for this span 4x8 Section used for this span 4x8 fb: Actual = 283.72psi fv: Actual = 26.02 psi Fb: Allowable = 1,105.00psi Fv: Allowable = 150.00 psi Load Combination +D+0.750Lr+0.750L Load Combination +D+0.750Lr+0.750L Location of maximum on span = 2.500ft Location of maximum on span = 0,000ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.019 in Ratio = 3234>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.024 in Ratio = 2510 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FIV C i C r C m C t O L M fb F'b V fv Fv D Only 0.00 0.00 0.00 0.00 Length = 5.0 ft 1 0.063 0.042 0.90 1.300 0.80 1.00 100 1.00 1.00 0.13 49.81 795.60 0.08 4.57 10810 +D+L 1,300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0,00 0.00 Length = 5.0 It 1 0.160 0.108 1.00 1.300 0.80 1.00 100 1,00 1.00 0.36 141.54 884.00 0.22 12.98 120.00 +D+Lr 1,300 0,80 1.00 1.00 1.00 1.00 0.00 0.00 0,00 0.00 Length = 5.0 ft 1 0.244 0.165 1.25 1.300 0.80 1.00 1.00 1.00 1.00 0.69 269.96 1105,00 0.42 24.76 150.00 +D+0,750Lr+0.750L 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0,00 0,00 0.00 Length = 5.0 It 1 0.257 0,173 1.25 1,300 0.80 1.00 1.00 1.00 1.00 0,72 283.72 1105.00 Q44 26.02 150.00 +D+0.750L 1.300 0.80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 5.0 ft 1 0.117 0,079 1.15 1.300 0.80 1.00 1.00 1.00 1.00 0,30 118.61 1016.60 0.18 10.88 138,00 +0.60D 1.300 0,80 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 5.0 ft 1 0,021 0,014 1.60 1.300 0.80 1.00 1.00 1.00 1.00 0.08 29.89 1414.40 0.05 2.74 192,00 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed: 23 SEP 2021, 1 14PM Wood Beam File:9371,ec6 Soi{WareCopy i�lEiJ✓ RCALC, lNC. 1993272p, BuiId:12.20.7 DESCRIPTION: BM#8: Exterior Patio Beam Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination +0+0.750Lr+0.750L 1 0.0239 2.518 Vertical Reactions Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 0.580 0.580 Overall MINimum 0.188 0.188 D Only 0.102 0.102 +D+L 0.289 0.289 +D+Lr 0.552 0.552 +D+0.750Lr+0.750L 0.580 0.580 +0+0.750L 0.242 0.242 +0.600 0.061 0.061 Lr Only 0.450 0.450 L Only 0.188 0.188 Max. "+" Deb Location in Span 0,0000 0.000 Values in KIPS Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr. 22,( Printed: 23 SEP 2021, 1:44PM Wood Beam File- 9371.ec6 Sofiwaretopprighl BNERCIIL+w, INC. 1983-2020, Build: 12.20.8.24 - i1 +L - DESCRIPTION: BM#9: Interior Joist Check CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 850.0 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 850.0 psi Ebend-xx 1,300.Oksi Fc • Prll 1,300.0 psi Eminbend - xx 470.0 ksi Wood Species : Hem -Fir Fc - Perp 405.0 ps) Wood Grade : No.2 Fv 150.0 psi Ft 525.0 psi Density 26.840pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling Repetitive Member Stress Increase D(0 016) L(0 05333) 2x6 Span = 7.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Uniform Load : D = 0,0160, L = 0.05333 , Tributary Width =1.0 ft, (FLR) DESIGN SUMMARY i.'' Maximum Bending Stress Ratio = 0.5421 Maximum Shear Stress Ratio = 0.263 : 1 Section used for this span 2x6 Section used for this span 2x6 fb: Actual = 688.76psi fv: Actual = 39.50 psi Fb: Allowable = 1,270.75psi Fv: Allowable = 150.00 psi Load Combination +D+L Load Combination +D+L Location of maximum on span = 1500ft Location of maximum on span = 6.566 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.107 in Ratio = 783>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.142 in Ratio = 589 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i Cr C m C t C L M fb Fb V fv F'v D Only 0,00 000 000 0.00 Length = 7A ft 1 0.149 0.072 0.90 1,300 1.00 1.15 1,00 1.00 1.00 0.11 170.45 1143.68 005 9,78 135.00 +D+L 1.300 1.00 1,15 1.00 1.00 1.00 0.00 000 0.00 0.00 Length = 7.0 It 1 0.542 0.263 1.00 1.300 1.00 1.15 1.00 1.00 1.00 0.43 688.76 1270.75 022 39.50 150.00 +D+0.750L 1.300 1.00 1.15 1.00 1.00 1.00 0.00 000 Ho 0.00 Length =7.0It 1 0.352 0.171 1,25 1,300 1.00 1.15 1.00 1.00 1.00 0.35 559.19 1588.44 018 32.07 187.50 +0.600 1,300 1.00 1.15 1.00 1.00 1.00 0.00 000 0.00 0.00 Length = TO ft 1 0.050 0.024 1.60 1.300 1.00 1.15 1.00 1.00 1.00 0.06 102.27 2033.20 003 5.87 240.00 Overall Maximum Deflections Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Deft Location in Span +D+L 1 0,1424 3,526 0,0000 0,000 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: zz, L Printed: 23 SEP 2021, 1 44PM Wood Beam File:9371.ec6 r &attwamo*y*i ENERCALC, INC, 1983.20M Build:12.20.8.24 DESCRIPTION: BM#9: Interior Joist Check Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Overall MAXimum 0.248 0.248 Overall MINimum 0.187 0,187 D Only 0.061 0.061 +D+L 0,248 0.248 +D+0,750L 0,201 0.201 +0.600 0,037 0.037 L Only 0.187 0.187 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: r, Printed: 23 SEP 2021 1:45PM Wall Footing File:9371.ec6 g Software cppyn0hl ENERCALC, INC. 1983.2020, Buildl2.20.8.24 DESCRIPTION: TypicalFoundationFooting Code References Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Material Properties Soil Design Values f'c : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing = 1.50 ksf fy : Rebar Yield - 40.0 ksi Increase Bearing By Footing Weight = No Ec : Concrete Elastic Modulus - 2,850.0 ksi Soil Passive Resistance (for Sliding) = 150.0 pcf Concrete Density - 145.0 pcf Soil/Concrete Friction Coeff. = 0.250 (p Values Flexure - 0.90 Shear - 0.750 Increases based on footing Depth Analysis Settings Reference Depth below Surface 24.Oft Min Steel % Bending Reinf. _ Allow. Pressure Increase per foot of depth ksf Min Allow % Temp Reinf. = 0.00180 when base footing is below = ft Min. Overturning Safety Factor = 1.0: 1 Increases based on footing Width Min. Sliding Safety Factor - 1,0 : 1 Allow, Pressure Increase per foot of width = ksf AutoCalc Footing Weight as DL Yes when footing is wider than = ft Adjusted Allowable Bearing Pressure 1.50 ksf Dimensions Reinforcing Footing Width - 1.333 ft Footing Thickness = 8.0 in Bars along X-X Axis Wall Thickness - 8.0 in Rebar Centerline to Edge of Concrete... Bar spacing = 12.00 Wall center offset at Bottom of footing = 3.0 in Reinforcing Bar Size = # 4 from center of footing = 0 in • r . • Gsrs.eum, �a:v w .z' Applied Loads D Lr L S W E H P : Column Load - 0.250 0.420 0.840 0.520 k OB : Overburden ksf V-x k M-zz k-ft Vx applied in above top of footing Wall Footing DESCRIPTION: Typical FoundationFooting DESIGN SUMMARY Factor of Safety Item PASS n/a Overturning - Z-Z PASS n/a Sliding - X-X PASS n/a Uplift Utilization Ratio Item PASS 0.6996 Soil Bearing PASS 0,03047 Z Flexure (+X) PASS 0.02004 Z Flexure (-X) PASS n/a 1-way Shear (+X) PASS 0,0 1-way Shear (-X) Detailed Results Soil Bearing Rotation Axis & Load Combination... D Onlv +D+L +D+Lr +D+S +D+0.750Lr+0,750L +D+0.750L+0, 750S +0,60D Overturning Stability Rotation Axis & Load Combination... Footing Has NO Overturning Sliding Stability Force Application Axis Load Combination... Footing Has NO Sliding Footing Flexure Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr- Printed: 23 SEP 2021, 1:45PM File, 9371 R 6 ' Software copyr h1 ENERCALC, INC. 1983.2020, Build:12.20,8.24 Applied Capacity Governing Load Combination 0.0 k-ft 0,0 k-ft No Overturning 0.0 k 0.0 k No Sliding 0.0 k 0.0 k No Uplift Applied Capacity Governing Load Combination 1.049 ksf 1.50 ksf +D+0.750L+0.750S 0.08853 k-ft 2.906 k-ft +1,20D+L+1.60S 0.05822 k-ft 2.906 k-ft +1.20D+L+0.20S 0.0 psi 75.0 psi n/a 0.0 psi 0.0 psi n/a Actual Soil Bearing Stress Actual I Allowable Gross Allowable Xecc -X +X Ratio 1,50 ksf 0 0 in 0.2842 ksf 0.2842 ksf 0.190 1 50 ksf 0.0 in 0.9144 ksf 0.9144 ksf 0.610 1 50 ksf 0.0 in 0.5993 ksf 0,5993 ksf 0,400 1 50 ksf 0.0 in 0.6743 ksf 0.6743 ksf 0.450 1 50 ksf 0.0 in 0.9931 ksf 0.9931 ksf 0,662 1 50 ksf 0,0 in 1.049 ksf 1.049 ksf 0.700 1 50 ksf 0.0 in 0.1705 ksf 0.1705 ksf 0.114 Units : k-ft Overturning Moment Resisting Moment Stability Ratio Status Sliding Force Resisting Force Sliding SafetyRatio Status Flexure Axis &Load Combination Mu Which Tension @ Bot. As Req'd Gvrn. As Actual As Phi*Mn k-ft Side ? or Top ? inA2 inA2 in"2 k-ft Status +1,40D 0,02208 -X Bottom 0.1728 Min Temp % 0,2 2.906 OR +1,40D 0.02208 +X Bottom 0.1728 Min Temo % 0.2 2,906 OR +1.20D+0,50Lr+1.60L 0,08362 -X Bottom 0.1728 Min Temo % 0.2 2.906 OR +1.20D+0.50Lr+1.60L 0,08362 +X Bottom 0,1728 Min Temp % 0,2 2.906 OR +1.20D+1,60L+0.50S 0.0857 -X Bottom 0,1728 Min Temo % 0,2 2.906 OR +1.20D+1,60L+0,50S 0,0857 +X Bottom 0.1728 Min Temo % 0.2 2.906 OR +1.20D+1.60Lr+L 0.08187 -X Bottom 0.1728 Min Temp % 0.2 2.906 OR +1.20D+1.60Lr+L 0,08187 +X Bottom 0,1728 Min Temo % 0.2 2.906 OR +1,20D+1,60Lr 0.0469 -X Bottom 0.1728 Min Temo % 0.2 2.906 OR +1,20D+1.60Lr 0.0469 +X Bottom 0,1728 Min Temp % 0.2 2.906 OR +1.20D+L+1.60S 0.08853 -X Bottom 0,1728 Min Temo % 0.2 2.906 OR +1.20D+L+1.60S 0.08853 +X Bottom 0,1728 Min Temo % 0.2 2.906 OR +1.20D+1.60S 0.05356 -X Bottom 0.1728 Min Temo % 0.2 2.906 OR +1.20D+1.60S 0.05356 +X Bottom 0.1728 Min Temo % 0.2 2.906 OR +1,20D+0.50Lr+L 0.06263 -X Bottom 0.1728 Min Temo % 0.2 2.906 OR +1,20D+0.50Lr+L 0.06263 +X Bottom 0,1728 Min Temo % 0.2 2,906 OR +1,20D+L+0.50S 0.06472 -X Bottom 0.1728 Min Temo % 0,2 2.906 OR +1.20D+L+0.50S 0.06472 +X Bottom 0,1728 Min Temp % 0.2 2.906 OR +0,90D 0.01419 -X Bottom 0.1728 Min Temo % 0,2 2,906 OR +0.90D 0.01419 +X Bottom 0,1728 Min Temo % 0.2 2.906 OR +1.20D+L+0.20S 0.05822 -X Bottom 0.1728 Min Temo % 02 2.906 OR +1.20D+L+0.20S 0D5822 +X Bottom 0,1728 Min Temo % 02 2.906 OR Wall Footing UMQILMr:i •rr: DESCRIPTION: TypicalFoundationFooting One Way Shear Load Combination... Vu @ -X Vu @ +X +1.40D 0 Dsi 0 osi Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: ) Printed: 23 SEP 2021, 1:45PM Flle: 9371.ec6 SofMare oopyrxy:u ENERCALCG iNG 1983.2D20. Build:12.20.8.24 Units : k Vu:Max Phi Vn Vu 1 Phi*Vn Status 0 psi '15 Dsi 0 OK Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: 2- Printed: 23 SEP 2021, 1:45PM Wall Footin Wg =i�E�" `'P Software oVy tENFRCAIC.INC.19812020. Build!12.20.8.24 DESCRIPTION: TypicalFoundation Footing One Way Shear Units ; k Load Combination... Vu @ -X Vu @ +X Vu:Max Phi Vn Vu I Phi"Vn Status +1.20D+0.50Lr+1.60L 0 osi 0 Dsi 0 Dsi 75 Dsi 0 OK +1,20D+1.60L+0.50S 0 psi 0 psi 0 Dsi 75 Dsi 0 OK +1,20D+1.60L►+L 0 osi 0 Dsi 0 Dsi 75 Dsi 0 OK +1.20D+1,60Lr 0 Dsi 0 DSI 0 Dsi 75 Dsi 0 OK +1.20D+L+1.60S 0 Dsi 0 osi 0 Dsi 75 Dsi 0 OK +1.20D+1.605 0 Dsi 0 Dsi 0 osi 75 Dsi 0 OK +1.20D+0,50Lr+L 0 Dsi 0 psi 0 Dsi 75 Dsi 0 OK +1.20D+L+0.50S 0 [)Si 0 Dsi 0 Dsl 75 Dsi 0 OK +0.90D 0 Dsi 0 osi 0 osi 75 Dsi 0 OK +1.200+L+020S 0 osi 0 Dsi 0 osi 75 Dsi 0 OK General Footing DESCRIPTION: Deck Footing Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: 2 Printed: 23 SEP 2021 3:53PM File: 9371.ec6 Software :,rpyri-jrn ENFRCALC. INC. 19WO20. Build:12,20.8.24 Code References Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Material Properties Soil Design Values fc : Concrete 28 day strength = 2.50 ksi Allowable Soil Bearing fy : Rebar Yield = 40.0 ksi Increase Bearing By Footing Weight Ec : Concrete Elastic Modulus = 2,850.0 ksi Soil Passive Resistance (for Sliding) Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. cp Values Flexure = 0.90 Shear = 0.750 Increases based on footing Depth Analysis Settings Footing base depth below soil surface Min Steel /o Bending Reinf. Allow press. increase per foot of depth Min Allow % Temp Reinf. 0,00180 when footing base is below Min. Overturning Safety Factor 1.0 1 Min. Sliding Safety Factor 1.0 1 Increases based on footing plan dimension Add Ftg Wt for Soil Pressure Yes Allowable pressure increase per foot of depth Use ftg wt for stability, moments & shears Yes Add Pedestal Wt for Soil Pressure No when max, length or width is greater than Use Pedestal wt for stability mom & shear No Dimensions Width parallel to X-X Axis = 1.50 ft Length parallel to Z-Z Axis = 1.50 ft Footing Thickness = 12.0 in Pedestal dimensions... px : parallel to X-X Axis = in pz : parallel to Z-Z Axis = in Height - in Rebar Centerline to Edge of Concrete.. at Bottom of footing = 3.0 in Reinforcing Bars parallel to X-X Axis Number of Bars 2.0 Reinforcing Bar Size = # 4 Bars parallel to Z-Z Axis Number of Bars = 2.0 Reinforcing Bar Size - # 4 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation n/a # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads D Lr P: Column Load = 2.40 OB : Overburden M-xx = M-zz - V-x = V-z - L S W 1.50 ksf No 150.0 pcf 0.250 2.0 ft ksf ft ksf ft E H k ksf k-ft k-ft k k Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: 7 f , Printed 23 SEP 2021, 3:53PM General FootingFile:9371ee6 , Software oapyrigMl ENERCALC.INC. 1983.2020. BuiId:12.20.8.24 DESCRIPTION: Deck Footing DESIGN SUMMARY a - e iii Min. Ratio Rem Applied Capacity Governing Load Combination PASS 0.8813 Soil Bearing 1,322 ksf 1.50 ksf D Only about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Overturning - Z-Z 0.0 k-ft 0.0 k-ft No Overturning PASS n/a Sliding - X-X 0.0 k 0.0 k No Sliding PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding PASS n/a Uplift 0.0 k 0.0 k No Uplift PASS 0.05972 Z Flexure (+X) 0,420 k-f /ft 7,033 k-ft/ft +1.40D PASS 0.05972 Z Flexure (-X) 0.420 k-ft/ft 7,033 k-ft/ft +1.40D PASS 0.05972 X Flexure (+Z) 0.420 k-ft/ft 7.033 k-ft/ft +1.40D PASS 0,05972 X Flexure (-Z) 0.420 k-f /ft 7.033 k-f ift +1.40D PASS n/a 1-way Shear (+X) 0,0 psi 75.0 psi n/a PASS 0.0 1-way Shear (-X) 0.0 psi 0.0 psi n/a PASS n/a 1-way Shear (+Z) 0.0 psi 75.0 psi n/a PASS n/a 1-way Shear (-Z) 0,0 psi 75.0 psi n/a PASS n/a 2-way Punching 7,778 psi 75.0 psi +1.400 Detailed Results Soil Bearing Rotation Axis & Xecc Zecc Actual Soil Bearing Stress Location Actual I Allow Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Let, -X Right, +X Ratio X-X, D Only 1.50 n/a 0.0 1.322 1.322 n/a n/a 0 881 X-X, +0.60D 1.50 n/a 0.0 0.7930 0.7930 Na n/a 0.529 Z-Z, D Only 1.50 0.0 n/a n/a n/a 1,322 1.322 0.881 Z-Z, +0.60D 1.50 0.0 n/a n/a nla 0,7930 0,7930 0.529 Overturning Stability Rotation Axis & Load Combination... Overturning Moment Resisting Moment Stability Ratio Status Footing Has NO Overturning Sliding Stability All units k Force Application Axis Load Combination... Sliding Force Resisting Force Stability Ratio Status Footing Has NO Sliding Footing Flexure Flexure Axis 8 Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi"Mn Status k-ft Surface inA2 inA2 in^2 k-ft X-X, +1.40D 0 420 +Z Bottom 0.2592 Min Temo % 0.2667 7.033 OK X-X, +1.40D 0A20 -Z Bottom 0.2592 Min TemD % 0.2667 7,033 OK X-X, +1.20D 0.360 +Z Bottom 0,2592 Min TemD % 0.2667 7.033 OK X-X, +1.20D 0.360 -Z Bottom 0.2592 Min Temo % 0.2667 7.033 OK X-X, +0.90D 0,270 +Z Bottom 0,2592 Min Temo % 0,2667 7.033 OK X-X, +0.90D 0,270 -Z Bottom 0,2592 Min Temo % 0.2667 7.033 OK Z-Z, +1.40D 0.420 -X Bottom 0,2592 Min TemD % 0,2667 7.033 OK Z-Z, +1,40D 0.420 +X Bottom 0.2592 Min Temo % 0.2667 7.033 OK Z-Z, +1.20D 0.360 -X Bottom 0.2592 Min Temo % 0,2667 7.033 OK Z-Z, +1,20D 0.360 +X Bottom 0.2592 Min Temo % 0.2667 7.033 OK Z-Z, +0.90D 0,270 -X Bottom 0.2592 Min Temo % 0.2667 7,033 OK Z-Z, +0.90D 0.270 +X Bottom 0,2592 Min Temo % 0.2667 7.033 OK One Way Shear Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu / Phi"Vn Status +1,40D 0.00 osi 0.00 Dsi 0.00 Dsi 0.00 osi 0,00 Dsi 75.00 osi 0.00 OK +1.20D 0,00 osi 0.00 osi 0.00 Dsi 0.00 osi 0.00 osi 75.00 osi 0.00 OK +0.90D 0,00 Dsi 0.00 osi 0.00 osi 0.00 osi 0,00 osi 75.00 osi 0.00 OK Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: General Footing DESCRIPTION: Deck Footing Printed: 23 SEP 2021, 3.53PM File:9371.ec6 Software W. yNloENERCALC.1NC. VKi,I420. Build:12.20.8.24 Two -Way "Punching" Shear All units k Load Combination... Vu Phi"Vn Vu I Phi"Vn Status +1,40D 7.78 osi 150,00osi 0.05185 OK +1,20D 6.67 osi 150.00osi 0,04444 OK +0.90D 5.00 osi 150.00osi 0.03333 OK Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: 7 Printed: 23 SEP 2021, 1 49PM File Wood Column :12.2 esfi SofhverecnpyriQht ENERCALC, INC. 1f183.242U, BuiId:12.20.8.24 is ri:Struct ural 0. DESCRIPTION: Stud Check Code References Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used: ASCE 7-16 General Information Analysis Method ; Allowable Stress Design Wood Section Name 2x6 End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 9 ft Wood Member Type Sawn { Used for non -slender calculations) Exact Width 1.50 in Allow Stress Modification Factors Wood Species Hem -Fir Exact Depth 5.50 in GForCvfor Bending 1.30 Wood Grade No.2 Area 8.250 inA2 Cf ar Cv for Compression 1.10 Fb + 575.0 psi Fv 140.0 psi Ix 20.797 in14 Cf or Cv for Tension 1.30 Fb - 575.0 psi Ft 375.0 psi ly 1.547 in14 Cm: Wet Use Factor 1.0 Fc - Prll 575.0 psi Density 26.840 pcf Ct : Temperature Factor 1.0 Fc - Perp 405.0 psi C% : Flat Use Factor 1.0 E : Modulus of Elasticity ... x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 1532 Basic 1,100.0 1,100.0 1,100.0 ksi Use Cr: Repetitive ? No Minimum 400.0 400.0 Brace condition for deflection (buckling) along columns : X-X (width) axis : Unbraced Length for buckling ABOUT Y-Y Axis = 2 ft, K = 1.0 Y-Y (depth) axis : Unbraced Length for buckling ABOUT X-X Axis = 2 ft, K = 1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations - Column self weiqht included :13.839 Ibs * Dead Load Factor AXIAL LOADS. . Axial Load at 9.0 ft, D = 4.0 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.9651 : 1 Maximum SERVICE Lateral Load Reactions . . Load Combination D Only Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fC/Fc' Top along X-X 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 4,014 k for load combination : n/a Applied Mx 0.0 k-ft Applied Along X-X 0.0 in at 0.0 ft above base Fc: Allowwaable si for load combination : n/a 11 psi 504.11 Other Factors used to calculate allowable stresses ... - PASS Maximum Shear Stress Ratio = 0.0 : 1 pending Compression Tension Load Combination +0.60D Location of max.above base 9.0 ft Applied Design Shear 0.0 psi Allowable Shear 224.0 psi Load Combination Results Maximu_rn Axial Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.886 0.9651 PASS O.0 ft 0.0 PASS 9.0 ft +0.60D 1.600 0.766 0.3764 PASS O,Oft 0.0 PASS 9.0 ft Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction It Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top D Only 4 014 +0.60D 2,408 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA49371 Project Descr: 5i Z Printed: 23 SEP 2021. 1:49PM File Wood Column 12.2 ec6 . 5altwarecopyri�h! ENERCALC, INC. 1983-2D211. Build:f2.2(1.9.24 DESCRIPTION: Stud Check Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance D Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft i0.60D 0.0000 In 0.000 ft 0,0000 in 0.000 ft Sketches +X c Load 1 0 LO 1.50 in Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr. J Printed: 23 SEP 2021, 2.02PM Wood Column Fuld:1 .ec6 Software E:HER{;I1l.C, INC. 1983.2020, BuiId:12.20.8.24 HL DESCRIPTION: Col#1 Code References Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Analysis Method : Allowable Stress Design Wood Section Name 4x4 End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber Overall Column Height 9 ft Wood Member Type Sawn { Used for non -slender calculations) Exact Widih 3.50 in Allow Stress Modification Factors Wood Species Douglas Fir -Larch Exact Depth 3.50 in Cf orCv for Bending 1.50 Wood Grade No.2 Area 12.250 in12 Cf or Cv for Cam ression 1.150 Fb + 900 psi Fv 180 psi Ix 12.505 in14 Cf or Cv for Tension 1.50 Fb - 900 psi Ft 575 psi ly 12.505 in^4 Cm :Wet Use Factor 1.0 Fc - Prll 1350 psi Density 31.21 pcf Ct : Temperature Factor 1.0 Fc - Perp 625 psi Cfu : Flat Use Factor 1.0 E : Modulus of Elasticity . , . x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 1532 Basic 1600 1600 1600 ksi Use Cr : Repetitive ? No Minimum 580 580 Brace condition for deflection (buckling) along columns : X-X (width) axis: Unbraced Length for buckling ABOUT Y-Y Axis = 9 ft, K = 1.0 Y-Y (depth) axis Unbraced Length for buckling ABOUT XA Axis = 9 ft, K = 1.0 Applied Loads Service loads entered. Load Factors will be applied for calculations. Column self weiqht included : 23.895 Ibs * Dead Load Factor AXIAL LOADS .. , Axial Load at 9.0 ft, D = 4.60 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = 0.8270 :1 Maximum SERVICE Lateral Load Reactions . . Load Combination D Only Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along XA 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections ... At maximum location values are ... Along Y-Y 0.0 in at 0.0 ft above base Applied Axial 4.624 k for load combination : n/a Applied Mx 0.0 k-ft Applied My 0.0 k-ft Along X-X 0.0 in at 0.0 ft above base Fc: Allowable 456.427 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio = 0.0 :1 pending L01 ress_Ion Tension Load Combination +0,600 Location of max.above base 9.0 ft Applied Design Shear 0.0 psi Allowable Shear 288.0 psi Load Combination Results Maximum Axial +• Bending Stress Ratios Maximum Shear Ratios Load Combination C D C p Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.327 0.8270 PASS 0.0ft 0.0 PASS 9.0 ft +0.60D 1.600 0.192 0.4739 PASS 0.0 ft 0.0 PASS 9.0 ft Maximum Reactions Note: Only non -zero reactions are listed X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k-ft Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top D Only 4.624 +0.60D 2.774 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA9371 „f Project Descr: Printed: 23 SEP 2021, 2:02PM Wood Column file; 937t.ec6 SgtAv�re a�pynghl tNERCAI.�. INC 1983-2(12Q, BmId:12. 20.9.2A DESCRIPTION: Col#1 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance D Only 0.0000 in 0.000 ft 0.0000 in 0,000 ft +0.60D 0.0000 in 0,000 ft 0.0000 in 0.000 ft Sketches c 0 co .�.Y 4);4 3.50 in Load 1 Project Title: Walla Addition Engineer: Chris Lalonde �} y,? r Project ID: SDA#9371 Project Descr: Printed: 23 SEP 2021, 11 50AM File: 9371.ecfi Wood Column Satlwerecropynghl ENERCALC, INC.1983-2020, BuiId;12.20.8.24 DESCRIPTION: Cantilever Post: Post Code References Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used: ASCE 7-16 General Information Analysis Method : Allowable Stress Design End Fixities Top Free, Bottom Fixed Overall Column Height 10 ft ( Used for non -slender calculations ) Wood Species Douglas Fir -Larch Wood Grade No.1 Fb + 1,200.0 psi Fv 170.0 psi Fb - 1,200 0 psi Ft 825.0 psi Fe - Prll 1,000.0 psi Density 31.210 pcf Fc - Perp 625.0 psi E : Modulus of Elasticity ... x-x Bending y-y Bending Basic 1,600.0 1,600.0 Minimum 580.0 580.0 Wood Section Name 8x8 Wood Grading/Manuf. Graded Lumber Wood Member Type Sawn Exact Width 7.50 in Allow Stress Modification Factors Exact Depth 7.50 in Cf or Cv for Bending T.0 Area 56.250 in"2 Cf or Cv for Compression 1.0 Ix 263.672 in14 Cf or Cv for Tension 1.0 ly 263.672 in^4 Cm: Wet Use Factor 1.0 Incising Factors : Ct : Temperature Factor 1.0 for Bending 0.80 Cfu : Flal Use tractor 1.0 Axial for Elastic Modulus 0.95 Kf : Built-up columns 1.0 NDS 1532 1,600.0 ksi Use Cr : Repetitive ? No Brace condition for deflection (buckling) along columns : X-X (width) axis : Unbraced Length for buckling ABOUT Y-Y Axis =10 ft, K = 2.1 Y-Y (depth) axis : Unbraced Length for buckling ABOUT X-X Axis =10 ft, K = 2.1 Applied Loads Column self weiqht included : 121.914 Ibs " Dead Load Factor AXIAL LOADS... Axial Load at 10.0 ft, D=1.440, Lr=1.920, S = 2.40 k BENDING LOADS ... Lat. Point Load at 10.0 ft creatinq Mx-x, E = 0.9840 k DESIGN SUMMARY Bending & Shear Check Results Service loads entered. Load Factors will be applied for calculations. PASS Max. Axial+Bending Stress Ratio = 0.8243 :1 Maximum SERVICE Lateral Load Reactions . . Load Combination +D+0,70E Top along Y-Y 0.9840 k Bottom along Y-Y 0.9840 k Governing NDS Forumld 1 Comp + Mxx, NDS Eq. 3.9-3 Top along X-X 0.0 k Bottom along X-X 0.0 k Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections... At maximum location values are ... Along Y-Y 1.407 in at 10.0 ft above base Applied Axial 1.562 k for load combination : E Only Applied Mx 6.8 k-ft Applied 0.0.0 Along X-X 0.0 in at 0.0 ft above base Fc Allowable: si 388.450 psi for load combination : n/a Other Factors used to calculate allowable stresses ... PASS Maximum Shear Stress Ratio = 0.08441 :1 Bending Compression Tension Load Combination +D+0,70E Location of max.above base 9.933 ft Applied Design Shear 18.368 psi Allowable Shear 217.60 psi Load Combination Results Maximum Axial +Bending Stress Ratios Maximum Shear Ratios Load Combination C D C P Stress Ratio Status Location Stress Ratio Status Location D Only 0.900 0.492 0.07846 PASS 0.0ft 0.0 PASS 10.0 ft +D+Lr 1.250 0.377 0.1643 PASS O.Oft 0.0 PASS 10.0 ft +D+S 1,150 0.404 0.1894 PASS 0.0ft 0.0 PASS 10.0 ft +D+0.750Lr 1.250 0.377 0.1417 PASS 0.0ft 0.0 PASS 10.0 ft +D+0.750S 1.150 0.404 0.1607 PASS 0.0ft 0.0 PASS 10,Oft +0.60D 1.600 0.303 0.04289 PASS O.Oft 0.0 PASS 10.0 ft +D+0.70E 1.600 0.303 0.8243 PASS 0.0 ft 0.08441 PASS 9.933 ft +D+0.750S+9.5250E 1.600 0.303 0.6923 PASS 0.0 ft 0.06331 PASS 9.933 ft +0.60D+0.70E 1.600 0.303 0.7986 PASS 0.0 ft 0.08441 PASS 9,933 ft Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 /� r Project Descr: Printed: 23 SEP 2021 11.50AM F Wood Column File: .ec6 Soflwareti�gpynant ENFRCALC. INC. 1983-2020. BuiId:12.20.8,24 DESCRIPTION: Cantilever Post: Past Maximum Reactions Note: Only non -zero reactions are listed. X-X Axis Reaction k Y-Y Axis Reaction Axial Reaction My - End Moments k- t Mx - End Moments Load Combination @ Base @ Top @ Base @ Top @ Base @ Base @ Top @ Base @ Top D Only 0.984 1.562 +D+Lr 0.984 3.482 +D+S 0.984 3,962 +D+0.750Lr 0.984 3.002 +D+0.750S 0.984 3.362 +0.60D 0.984 0.937 +0+0.70E 0.689 0.984 1562 6.888 +D+0.750S+0.5250E 0.517 0.984 3.362 5.166 +0,60D+0.70E 0.689 0.984 0.937 6.888 Lr Only 0.984 1.920 S Only 0.984 2.400 E Only 0.984 0.984 9.840 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance D Only 0.0000 in 0,000 ft 0.0000 in 0.000 ft +D+Lr 0.0000 in 0.000 ft 0.0000 in 0.000 ft +D+S 00000 in 0.000 ft 0.0000 in 0.000 ft +D+0.750Lr 0.0000 in 0.000 ft 0.0000 in 0.000 It +D+0.750S 0.0000 in 0.000 ft 0000 in 0.000 It +0.60D 0.0000 in 0.000 ft 0.0000 in 0.000 It +D+0.70E 0.0000 In 0.000 ft 0.9849 in 10.000 It +D+0.750S+0.5250E 0.0000 in 0.000 ft 0.7387 in 10.000 It +0.60D+0.70E 0.0000 In 0.000 ft 0,9849 in 10.000 ft Lr Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft S Only 0.0000 in 0.000 ft 0.0000 in 0.000 ft E Only 00000 in 0.000 it 1,3928 in 9.933 ft Project Title: Walla Addition Engineer: Chris Lalonde Protect ID: SDA#9371 , Project Descr: Printed: 23 SEP 2021, 11;50AM File: 9371.ec6 Wood Column Soflwamoppnht ENERCAM INC 1983.2020, Build:12.201.24 DESCRIPTION: Cantilever Post: Post Sketches 8x8 7.50 in Load 1 +X Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: j r Printed: 23 SEP 2021, 12 34PM File:937 Steel Base Plate 08.2424 Softwarecvpyrx2hl ENERCA�C. INC �136&202U. BuiId;12.20.8 DESCRIPTION: Cantilever Post: Baseplate Code References Calculations per AISC Design Guide # 1, IBC 2018, CBC 2019, ASCE 7-16, AISC 360-16 Load Combination Set: ASCE 7-16 General Information Material Properties AISC Design Method Load Resistance Factor Design (D c : LRFD Resistance Factor 0,65 Steel Plate Fy = 36 ksi Concrete Support fc = 3 ksi Assumed Bearing Area: Full Bearing Nominal Bearing Fp per J8 2.550 ksi Column & Plate Column Properties 1'4" Steel Section: HSS8x8x3/16 Z Depth 8 in Area 5.37 in^2 Width 8 in Ixx 54.4 in^4 Flange Thickness 0.174 to In 54.4 in^4 Web Thickness in Plate Dimensions Support Dimensions N : Length 16.0 in Width along X' 16.0 in X B : Width 16.0 in Length along "Z' 16,0 in A Thickness 0.6250 in Column assumed welded to base plate. - Usm Applied Loads P-Y D : Dead Load ....... k L : Live ....... k Lr : Roof Live ......... k S : Snow ............... k W : Wind ................ k E : Earthquake k H : Lateral Earth k " P " = Gravity load, "+" sign is downward. AnchorBolts Anchor Bolt or Rod Description 1 1 /2" Max of Tension or Pullout Capacity........;. Shear Capacity ......................................... Edge distance : bolt to plate ...... -........... Number of Bolts in each Row ................... Number of Bolt Rows ........................ V-Z M-X k k-ft k k-ft k k-ft k k-ft k k-ft 0,9840 k 9,840 k-ft k k-ft Moments create higher soil pressure at +Z edge. Shears push plate towards +Z edge. k k 1.25 in 2 1 rt 1. _4„ Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: _ , . J r �! Printed 23 SEP 2021. 12-34PM Steel Base Plate File: .ec8 Software ENERCALC. INC. 1903.2020, BuiId:12.20.8,24 12.2 .- DESCRIPTION: Cantilever Post: Baseplate GOVERNING DESIGN LOAD CASE SUMMARY Mu: Max. Moment .................... 2.332 k-in Plate Design Summary fb : Max. Bending Stress -,........... 23.878 ksi Design Method Load Resistance Factor Design Flo: Allowable: 32.400 ksi Governing Load Combination E Only Fy " Phi Governing Load Case Type Axial + Moment, U2 < Eccentricity, Tension on Bending Stress Ratio 0 737 Governing STRESS RATIO 1.0 Bending Stress OK Design Plate Size 1'4' x 1'-4" x 0 -518 fu : Max. Plate Bearing Stress ... 1.658 ksi Pu : Axial ......... 0 000 k Fp : Allowable: 1.658 ksi Mu : Moment ........ 0.000 k-ft Bearing Stress Ratio 1,000 Bearing Stress OK Load Comb.: Loading Pu : Axial ......... Design Plate Height......... Design Plate Width......... Will be different from entry if partial bearing used. Al : Plate Area......... A2: Support Area .............. sgrt(A21A1 ) Distance for Moment Calculation m ` n ........ ............1. X............................. Lambda ............. n' " Lambda ........................... L = max(m, n, n") .................. Load Comb.: E Only Loadiag Pu : Axial ,........ Mu: Moment ,....... Eccentricity ........................ Al : Plate Area ......... A2 : SupportArea ..................... sqrt( A21A1 ) Calculate plate moment from bearing- . max(m, n) "A" : Bearing Length Mpl : Plate Moment 0.000 k 16.000 in 16.000 in 256.000 in A2 256.000 in A2 1,000 4.200 in 4-200 in 0,000 i02 0.000 0-000 in 0.000 in 4.200 in 0,000 k 9.840 k-ft ### in 256,000 inA2 256.000 in A2 1.000 Bearing Stresses Fp : Allowable ............................. fu : Max. Bearing Pressure Stress Ratio ..................... Plate Sending Stresses Mmax = Fu " LA2 12 ................... fb: Actual ................................ Fb : Allowable ............................ Stress Ratio ..................... Axial Load Only, No Moment 1.658 ksi uw ksi 0.000 U00 k-in 0.000 ksi 32.400 ksi 0.000 Axial Load + Moment, Ecc. > L12 Calculate place moment from halt tension .. . Tension per Hot .... ............... Tension: Allowable .................... Stress Ratio .................... Dist. from Bolt to Cal. Edge ............. Effective Bolt Width for Bending ..... Plate Moment from Bolt Tension ....... 4.800 in Bearing Stresses 0.612 in Fp : Allowable ........ ........... 0.194 k-in fu : Max. Bearing Pressure Stress Ratio .................... Plate Sendinci Stresses Mmax................................,......... fb : Actual ............................ Fb : Allowable ............................. . Stress Ratio .................... 4.059 k 0.000 k 0.000 2.950 in 11.800 in 2.029 k-in 1.658 ksi ( set equal to Fp ) 1.000 2.332 k-in 23.878 ksi 32.400 ksi 0.737 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr. Printed: 23 SEP 2021, 11:50AM Steel Column File:9371.ec6 Soflwareoopprfght ENERCAI-C, INC 1983-2020. Build:12.20.8.24 DESCRIPTION: Cantilever Post: Sleeve Code References Calculations per AISC 360-16, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used: ASCE 7-16 General Information Steel Section Name: HSS8x8x3/16 Analysis Method : Allowable Strength Steel Stress Grade Fy : Steel Yield 36.0 ksi E : Elastic Bending Modulus 29,000.0 ksi Applied Loads Column self weight included : 58.890 Ibs " Dead Load Factor BENDING LOADS ... Moment acting about X-X axis at 3.0 ft, E = 9.840 k-ft Lat. Point Load at 3.0 ft creating Mx-x, E = 0.9840 k DESIGN SUMMARY Bending & Shear Check Results PASS Max. Axial+Bending Stress Ratio = Load Combination Location of max.above base At maximum location values are.. . Pa: Axial Pn / Omega: Allowable Ma-x : Applied Mn-x / Omega: Allowable Ma-y : Applied Mn-y / Omega: Allowable Overall Column Height 3.0 ft Top & Bottom Fixity Top Free, Bottom Fixed Brace condition for deflection (buckling) along columns X-X (width) axis : Unbraced Length for buckling ABOUT Y-Y Axis = 3 ft, K = 2.1 Y•Y {depth) axis : Unbraced Length for buckling ABOUT X-X Axis = 3 ft, K = 2.1 Service loads entered. Load Factors will be applied For calculations. 0.2919 : 1 Maximum Load Reactions.. +D+0.70E Top along X-X 2.980 ft Bottom along X-X Top along Y-Y 0.05889 k Bottom along Y-Y 107.763 k 6.874 k-ft Maximum Load Deflections ... 23.572 k-ft Along Y-Y-0.03853 in at for load combination : E Only 0.0 k-ft 23.572 k-ft Along X-X 0.0 in at for load combination : PASS Maximum Shear Stress Ratio = 0.02046 :1 Load Combination +D+0.70E Location of max.above base 0.0 ft At maximum location values are. . Va : Applied 0.6888 k Vn / Omega : Allowable 33.659 k Load Combination Results Maximum Axial + Bendinn Stress Ratios Load Combination Stress Ratio Status Location Cbx Cby KxLx/Rx D Only 0.001 PASS 0.00 ft 1.13 1.00 23.77 +0.60D 0.000 PASS 0.00 ft II A 3 1.00 23.77 +D+0.70E 0.292 PASS 2.98 ft 1 13 1.00 23.77 +D+0.5250E 0.219 PASS 2.98 ft 1.13 1.00 23.77 +0.60D+0.70E 0.292 PASS 2.98 ft 1.13 1.00 23.77 Maximum Reactions Axial Reaction X-X Axis Reaction k Y-Y Axis Reaction Load Combination @ Base @ Base @ Top @ Base @ Top D Only 0.059 +0.60D 0.035 +D+0.70E 0.059 0.689 +D+0.5250E 0.059 0.517 +0.600+0,70E 0.035 0.689 E Only 0.984 0.0 k 0.0 k 0.0 k 0.9840 k 3.0ft above base 0.0ft above base Maximum Shear Ratios KyLy/Ry Stress Ratio Status Location 23.77 0.000 PASS 0,00 ft 23.77 0.000 PASS 0.00 ft 23.77 0.020 PASS 0.00 ft 23.77 0.015 PASS 0.00 ft 23.77 0.020 PASS 0.00 ft Note: Only non -zero reactions are listed Mx - End Moments k-ft My - End Moments @ Base @ Top @ Base @ Top 4.822 3.616 4.822 6.888 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: DESCRIPTION: Cantilever Post: Sleeve Extreme Reactions Axial Reaction Item Extreme Value @ Base Axial @ Base Maximum 0,059 " Minimum Reaction, X-X Axis Base Maximum 0.059 " Minimum 0.059 Reaction, Y-Y Axis Base Maximum " Minimum 0.059 Reaction, X-X Axis Top Maximum 0.059 " Minimum 0.059 Reaction, Y-Y Axis Top Maximum 0.059 " Minimum 0.059 Moment, X-X Axis Base Maximum " Minimum 0.059 Moment, Y-Y Axis Base Maximum 0.059 Minimum 0.059 Moment, X-X Axis Top Maximum 0.059 " Minimum 0.059 Moment, Y-Y Axis Top Maximum 0.059 " Minimum 0.059 Maximum Deflections for Load Combinations Load Combination Max. X-X Deflection D Only 0,0000 in +0.60D 0.0000 in +D+0.70E 0,0000 in +D+0.5250E 0.0000 in +0.600+0.70E 0.0000 in E Only 0,0000 in Steel Section Properties : HSS8x8x3116 Depth = 8,000 in I xx Design Thick = 0.174 in S xx Width 8.000 in R xx Wall Thick = 0.187 in Zx Area = 5.370 in"2 Iyy Weight = 19.630 plf S yy R yy Ycg = 0.000 in X-X Axis Reaction k Y-Y Axis Reaction @ Base @ Top @ Base @ Top 0.984 0.984 Printed: 23 SEP 2021, 11:50AM File: 9371.ec6 ENERCALC, INC. 1983-2020, Build:12.20.8.24 Mx - End Moments k-ft My - End Moments @ Base @ Top @ Base @ Top 6,888 6.888 6.888 0.984 6.888 Distance Max. Y-Y Deflection Distance 0.000 ft 0.000 in 0.000 ft 0.000 ft 0.000 in 0.000 ft 0.000 It -0,027 in 3.000 ft 0.000 ft -0.020 in 3.000 ft 0.000 It -0,027 in 3.000 ft 0.000 It -0.038 in 2.980 ft = 54,40 in^4 J - 84.500 in^4 - 13.60 in^3 - 3,180 in = 15.700 in^3 - 54.400 in^4 C - 21.300 inA3 - 13.600 in"3 = 3.180 in Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Steel Column DESCRIPTION: Cantilever Post: Sleeve Sketches c 0 0 cw +Y 8.00in Printed: 23 SEP 2021, 11:50AM File: 9371.ec6 Softwarecopy hl ENE_RCALC. INC 1%3.207.0, Build:12.20,8.24 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 ��, Project Descr: Printed 23 SEP 2021. 11 50AM General FootingFue:93y'ec6 Software ;crpyright ENERGALC, INC 19A3-2020, BiId:12.20,6.24 DESCRIPTION: Cantilever Post: Footing Code References Calculations per ACI 318-14, IBC 2018, CBC 2019, ASCE 7-16 Load Combinations Used: ASCE 7-16 General Information Material Properties Soil Design Values fc : Concrete 28 day strength = 2•50 ksi Allowable Soil Bearing fy : Rebar Yield - 40.0 ksi Increase Bearing By Footing Weight Ec : Concrete Elastic Modulus - 2,850.0 ksi Soil Passive Resistance (for Sliding) Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. cp Values Flexure = 0.90 Shear = 0.750 Increases based on footing Depth Analysis Settings Footing base depth below soil surface Min Steel % Bending Reinf. Allow press. increase per foot of depth Min Allow % Temp Reinf. 0-00180 when footing base is below Min. Overturning Safety Factor - 1.0 Min. Sliding Safety Factor 1.0 i Increases based on footing plan dimension Add Ftg Wt for Soil Pressure Yes Allowable pressure increase per foot of depth Use ftg wt for stability, moments & shears Yes when max. length or width is greater than Add Pedestal Wt for Soil Pressure No Use Pedestal wit for stability mom & shear No Dimensions Width parallel to X-X Axis = 5.0 ft Length parallel to Z-Z Axis = 5.0 ft Footing Thickness - 18.0 in Pedestal dimensions... px : parallel to X-X Axis = in pz : parallel to Z-Z Axis = in Height = in Rebar Centerline to Edge of Concrete. at Bottom of footing = 3.0 in Reinforcing Bars parallel to X-X Axis Number of Bars - 10.0 Reinforcing Bar Size - # 4 Bars parallel to Z-Z Axis Number of Bars = 10.0 Reinforcing Bar Size = # 4 Bandwidth Distribution Check (ACI 15.4.4.2) Direction Requiring Closer Separation n/a # Bars required within zone n/a # Bars required on each side of zone n/a Applied Loads D Lr P : Column Load = 1.440 1.920 OB : Overburden = M-xx = M-zz = V-x = V-z = 1.50 ksf No = 150.0 pcf = 0.250 2.0 ft ksf ft ksf ft L S W E H 2.40 k ksf k-ft 9.840 k-ft 0.9840 k k Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 r(.. Project Descr: Printed: 23 SEP 2021. 11:50AM General FootingFile' 9371.ec6 Software t ENERCALC, INC. 1983-2020, Build:12.20.8.24 Itii r:r -��. �• DESCRIPTION: Cantilever Post: Footing DESIGN SUMMARY Min. Ratio Item Applied Capacity Governing Load Combination PASS 0.4844 Soil Bearing 0.7266 ksf 1.50 ksf +0.60D+0.70E about Z-Z axis PASS n/a Overturning - X-X 0.0 k-ft 0.0 k-ft No Overturning PASS 1.563 Overturning - Z-Z 7.921 k-ft 12.379 k-ft +0.60D+0.70E PASS 3.839 Sliding - X-X 0.6888 k 2.644 k +0.60D+0.70E PASS n/a Sliding - Z-Z 0.0 k 0.0 k No Sliding PASS n/a Uplift 0:0 k 0.0 k No Uplift PASS 0.08518 Z Flexure (+X) 1.501 k-ft/ft 17,624 k-ft/ft +0.90D+E PASS 0.04661 Z Flexure (-X) 0.8215 k-ft/ft 17.624 k-ft/ft +1.20D+0.20S+E PASS 0.03949 X Flexure (+Z) 0,6960 k-ft/ft 17.624 k-f /ft +1.20D+1.60S PASS 0.03949 X Flexure (-Z) 0,6960 k-ft/ft 17.624 k-ft/ft +1:20D+1 60S PASS 0.05116 1-way Shear(+X) 3.837 psi 75.0 psi +0.90D+E PASS 0.02830 1-way Shear (-X) 2.122 psi 75.0 psi +1.20D+0.20S+E PASS 0,02062 1-way Shear (+Z) 1.547 psi 75.0 psi +1.20D+1.60S PASS 0.02062 1-way Shear (-Z) 1.547 psi 75.0 psi +1.20D+1.60S PASS 003867 2-way Punching 5.80 psi 150:0 psi +1.20D+1.60S Detailed Results Soil Bearing Rotation Axis & Xecc Zecc Actual Soil Bearing Stress @ Location Actual I Allow Load Combination... Gross Allowable (in) Bottom, -Z Top, +Z Left, -X Right, +X Ratio X-X. D Only 1,50 n/a 0.0 0.3301 0.3301 n/a n/a 0.220 X-X, +D+Lr 1.50 n/a 0.0 0.4069 0,4069 n/a n/a 0.271 X-X, +D+S 1.50 n/a 0.0 0,4261 0.4261 n/a n/a 0,284 X-X, +D+0.750Lr 1.50 n/a 0.0 0.3877 0.3877 n/a n/a 0.259 X-X, +D+0.750S 1.50 n/a 0.0 0.4021 0,4021 n/a n/a 0.268 X-X, +0.60D 1.50 n/a 0.0 0.1981 0.1981 n/a n/a 0.132 X-X, +D+0.70E 1.50 n/a 0.0 0.3301 0.3301 n/a n/a 0-220 X-X, +D+0.750S+0.5250E 1 50 n/a 0.0 0,4021 0.4021 n/a n/a 0.268 X-X, +0.60D+0.70E 1.50 n/a 0.0 0.1981 0.1981 n/a n/a 0.132 Z-Z, D Only 1.50 0.0 n/a n/a n/a 0.3301 0.3301 0.220 Z-Z, +D+Lr 1.50 0.0 n/a n/a n/a 0.4069 0.4069 0 271 Z-Z, +D+S 1.50 0.0 n/a n/a n/a 0.4261 0.4261 0 284 Z-Z, +D+0.750Lr 1.50 0.0 n/a n/a n/a 0.3877 0.3877 0 259 Z-Z, +D+0.750S 1.50 0.0 n/a n/a n/a 0.4021 0.4021 0 268 Z-Z, +0.60D 1.50 0.0 n/a n/a n/a 0.1981 0.1981 0132 Z-Z, +D+0.70E 1.50 11.518 n/a n/a n/a 0.0 0,7106 0,474 Z-Z, +D+0.750S+0:5250E 1,50 7.092 n/a n/a n/a 0.1198 0.6844 0.456 Z-Z, +0.60D+0.70E 1.50 19.197 n/a n/a n/a 0.0 0,7266 0.484 Overturning Stability Rotation Axis & Load Combination... Overturning Moment Resisting Moment Stability Ratio Status X-X, D Only None 0.0 k-ft Infinity OK X-X, +D+Lr None 0.0 k-ft Infinity OK X-X. +D+S None 0.0 k-ft Infinity OK X-X, +D+0.750Lr None 0.0 k-ft Infinity OK X-X, +D+0.750S None 0.0 k-ft Infinity OK X-X, +0.60D None 0.0 k-ft Infinity OK X-X, +D+0.70E None 0.0 k-ft Infinity OK X-X, +D+0.750S+0,5250E None 0.0 k-ft Infinity OK X-X, +0.60D+0.70E None 0.0 k-ft Infinity OK Z-Z, D Only None 0.0 k-ft Infinity OK Z-Z, +D+Lr None 0.0 k-ft Infinity OK Z-Z, +D+S None 0.0 k-ft Infinity OK Z-Z. +D+0,750Lr None 0.0 k-ft Infinity OK Z-Z, +D+0.750S None 0.0 k-ft Infinity OK Z-Z, +0.60D None 0.0 k-ft Infinity OK Z-Z, +D+0.70E 7.921 k-ft 20.631 k-ft 2.605 OK Z-Z, +D+0.750S+0,5250E 5.941 k-ft 25,131 k-ft 4.230 OK Z-Z, +0.60D+0.70E 7.921 k-ft 12.379 k-ft 1,563 OK Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: General Footing Software Printed: 23 SEP 2021, 11:50AM File: 9371.ec6 t.KftENERCAI.C.INC.1983-2020,Build:12.20.8.24 DESCRIPTION: Cantilever Post: Footing Sliding Stability All units k Force Application Axis Load Combination... Sliding Force Resisting Force Stability Ratio Status X-X, D Only 0.0 k 3.469 k No Slidino OK X-X, +D+Lr 0 0 k 3.949 k No Sliding OK X-X, +D+S 0.0 k 4.069 k No Slidino OK X-X, +D+0.750Lr 0 0 k 3.829 k No Slidino OK X-X, +D+0.750S 0 0 k 3.919 k No Sliding OK X-X, +0.60D 0.0 k 2,644 k No Slidino OK X-X, +D+0.70E 0 6888 k 3.469 k 5.037 OK X-X, +D+0.750S+0.5250E 0 5166 k 3.919 k 7.587 OK X-X, +0.60D+0.70E 0.6888 k 2.644 k 3.839 OK Z-Z, D Only 0.0 k 3.469 k No Slidino OK Z-Z, +D+Lr 0.0 k 3.949 k No Slldina OK Z-Z, +D+S 0.0 k 4.069 k No Slldina OK Z-Z, +D+0.750Lr 0.0 k 3.829 k No Slidina OK Z-Z, +D+0.70E 0.0 k 3,469 k No Slidino OK Z-Z. +D+0.750S+0.5250E 0.0 k 3.919 k No Slidino OK Z-Z, +0.60D+0.70E 0.0 k 2.644 k No Slidino OK Z-Z, +D+0.750S 0.0 k 3.919 k No Slidino OK Z-Z, +0.60D 0.0 k 2,644 k No Slldina OK Footing Flexure Flexure Axis &Load Combination Mu Side Tension As Req'd Gvrn. As Actual As Phi*Mn Status k-ft Surface in"2 in"2 in^2 k-ft X-X. +1.401) 02520 +Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X, +1.40D 0.2520 -Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X. +1,20D+0.50Lr 0.3360 +Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X. +1.20D+0.50Lr 0.3360 -Z Bottom 0.3888 Min Temo % 0,40 17.624 OK X-X, +1.20D+0.50S 0.3660 +Z Bottom 0.3888 Min Temo % 0.40 17,624 OK X-X, +1.20D+0.50S 0.3660 -Z Bottom 0.3888 Min Temo % 0,40 17,624 OK X-X, +1.20D+1.60Lr 0.60 +Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X, +1.20D+1.60Lr 0.60 -Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X, +1.20D+1.60S 0,6960 +Z Bottom 0,3888 Min Temo % 0.40 17,624 OK X-X. +1.20D+1.60S 0.6960 -Z Bottom 0.3888 Min Temo % 0.40 17,624 OK X-X, +0.900 0.1620 +Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X, +0.90D 0.1620 -Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X, +1.20D+0.20S+E 0.2760 +Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X, +1.20D+0.20S+E 0.2760 -Z Bottom 03888 Min Temo % 0.40 17.624 OK X-X, +0.90D+E 0.1620 +Z Bottom 0.3888 Min Temo % 0.40 17.624 OK X-X, +0.90D+E 0.1620 -Z Bottom 0.3888 Min Temp % 0.40 17.624 OK Z-Z, +1.40D 0.2520 -X Bottom 0.3888 Min Temo % 0.40 17.624 OK Z-Z, +1.40D 0.2520 +X Bottom 0.3888 Min Temo % 0.40 17.624 OK Z-Z, +1.20D+0.50Lr 0,3360 -X Bottom 0.3888 Min Temp % 0,40 17.624 OK Z-Z, +1.20D+0.50Lr 0.3360 +X Bottom 0.3888 Min Temo % 0.40 17.624 OK Z-Z, +1.20D+0.50S 0,3660 -X Bottom 0.3888 Min Temp % 0.40 17.624 OK Z-Z, +1.20D+0.50S 0.3660 +X Bottom 0,3888 Min Temo % 0.40 17.624 OK Z-Z. +1.20D+1.60Lr 0.60 -X Bottom 0.3888 Min Temo % 0.40 17 624 OK Z-Z, +1.20D+1.60Lr 0.60 +X Bottom 0.3888 Min Temp % 0.40 17.624 OK Z-Z, +1.20D+1.60S 0.6960 -X Bottom 0.3888 Min Temp % 0.40 17.624 OK Z-Z, +1.20D+1.60S 0,6960 +X Bottom 0,3888 Min Temo % 0.40 17.624 OK Z-Z, +0.90D 0.1620 A Bottom 0.3888 Min Temp % 0.40 17,624 OK Z-Z, +0.90D 0.1620 +X Bottom 0.3888 Min Temp % 0.40 17.624 OK Z-Z, +1.20D+0.20S+E 0,8215 -X Top 0.3888 Min Temp % 0.40 17,624 OK Z-Z, +1.20D+0.20S+E 1.442 +X Bottom 0.3888 Min Temp % 0.40 17.624 OK Z-Z, +0.90D+E 0.7618 -X Top 0.3888 Min Temp % 0.40 17.624 OK Z-Z. +0.90D+E 1.501 +X Bottom 0.3888 Min Temp % 0.40 17.624 OK One Way Shear Load Combination... Vu @ -X Vu @ +X Vu @ -Z Vu @ +Z Vu:Max Phi Vn Vu I Phi*Vn Status +1.40D 0.56 psi 0.56 osi 0.56 osi 0,56 psi 0.56 osi 75.00 psi 0.01 OK +1.20D+0.50Lr 0.75 osi 0.75 psi 0.75 osi 0.75 psi 0.75 psi 75.00 osi 0.01 OK +1.20D+0.50S 0.81 psi 0,81 osi 0,81 osi 0.81 osi 0,81 osi 75.00 psi 0,01 OK +1.20D+1.60Lr 1.33 psi 133 osi 1.33 psi 1.33 psi 1,33 osi 75.00 osi 0.02 OK +1.20D+1.60S 1.55 psi 1.55 osi 1.55 osi 1.55 osi 1.55 osi 75.00 psi 0.02 OK Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 , Project Descr: Printed: 23 SEP 2021, 11.50AM General FootingFile: 9371•ee6 Soflwaree.wynghl ENERCALC, INC. 1983 2079• Build:12 2U.B.24 DESCRIPTION: Cantilever Post: Footing One Way Shear Load Combination... +0.90D +1.20D+0.20S+E +0.90D+E Two -Way "Punching" Shear Load Combination... +1.40D +1.20D+0.50Lr +1.20D+0.50S +1.20D+1.60Lr +1.20D+1.60S +0.90D +1.20 D+0.20S+E +0.90D+E Vu@ -x Vu@+x 0,36 osi 0.36 osi 2,12 osi 3,54 osi 1.70 osi 3.84 osi Vu 2.10 psi 2.80 osi 3.05 osi 5.00 osi 580 osi 1.35 osi 2.33 psi 1.61 psi Vu @ -Z Vu @ +Z Vu:Max 0.36 osi 0.36 psi 0.36 osi 0.61 psi 0.61 osi 3,54 osi 0.36 osi 0.36 osi 3.84 osi Phi"Vn 150.00 osi 150,00 osi 150.00 osi 150.00 osi 150.00 osi 150.00 osi 150.00 osi 150.00 osi Vu I Phi"Vn 0,014 0.01867 0,02033 0,03333 0.03867 0.009 0.01556 0.01074 Phi Vn Vu I Phi"Vn Status 75.00 osi 0.00 OK 75.00 psi 0.05 OK 75.00 osi 0.05 OK All units k Status OK OK OK OK OK OK OK OK t�I►'�i `-'-'��� Anchor DesignerT11 Software Version 3.0.7808.1 i.Proiggt Intonnatlor! Customer company: Customer contact name: Customer e-mail: Comment: 2. Inout Data & Anchor Parameters General Design method:ACI 318-14 Units: Imperial units Anchor Information: Anchor type: Cast -in -place Material: F1554 Grade 36 Diameter (inch): 1.125 Effective Embedment depth, het (inch): 12.000 Anchor category: - Anchor ductility: Yes hm,,, (inch): 13.88 Cmm (Inch): 6.75 Smin (inch): 6,75 Recommended Anchor Anchor Name: J- or L-Bolt - 1 1/8"0 J- or L-Bolt, F1554 Gr. 36 Company: Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page: 1/6 Pro ect: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com Project description: Location: 10406 226th PL SW Edmonds, WA 98020 Fastening description: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 18.00 State: Cracked Compressive strength, f� (psi): 2500 4)",v: 1.D Reinforcement condition: B tension, B shear Supplemental reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore Edo requirement: No Build-up grout pad: No Base Plate Length x Width x Thickness (inch): 16.00 x 16.00 x 0.25 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility r :} _ •r -•� 5956 ft Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560,9000 Fax: 925.847,3871 www.strangtie•com Anchor Designer TM Software Version 3.0.7808.1 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: No Anchors subjected to sustained tension: Not applicable Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: No Strength level loads: Nu. [lb]: 0 Vuer [lb]: 0 Vuay [lb]: -984 Mu. [ft-lb]: 9840 Muy [ft-lb]: 0 M. [ft-lb]: 0 <Figure 1> Company: Structural Design Associates Date: 9/23/2021 En ineer. Chris Lalonde Page: 2/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com 4, o tb t 0 Ft -lb _�• � �---slts�yisj��3� � _ �e :#,+ter �`.!4 -JOIF 14 Ib Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility- Sunpson Stranq-Tie Company Inr 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strangtie.com Anchor Designer"' Software Version 3.0.7808.1 <Figure 2> Company: Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page, 3/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Siir.pscn S".ro•,y-i z ;:,r;.,;,ny Inc 5956 W, L,as Positas Boulevard Pleasanton, CA 94588 Phone: 925,560-9000 Fax: 925-847.3871 www.strongtie.com Anchor DesignerT"" Software Version 3.0.7808.1 n Company. Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page: 4/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail; 1 clalonde@sdaeverett.com 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nua (lb) V- (lb) V-v (lb) 0"..)2+(Uuay)' (Ib) 1 0.0 -37.8 -283.8 286.4 2 4532.4 37.8 -283.8 286.4 3 4532.4 37.8 -208.2 211.6 4 0.0 -37.8 -208.2 211.6 Sum 9064.8 0.0 -984.0 995.8 Maximum concrete compression strain (%o): 0.06 <Figure 3> Maximum concrete compression stress (psi); 256 04 'Y Resultant tension force (lb): 9065 Resultant compression force (lb): 9065 Eccentricity of resultant tension forces in x-axis, e'N. (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 Eccentricity of resultant shear forces in x-axis, e'v. (inch): 0.00 Eccentricity of resultant shear forces in y-axis, e'vy (inch): 0.00 Y a_ 1� 4. Steel Strength of Anchor In TBnSIOn ISec. 17.4.11 Nsa (lb) 0 ONsa (lb) 44255 0.75 33191 S. Concrete r k rn h of Ancligrin7nin 17 Nb = k-a.4F.he l S (Eq. 17.4.2.2a) k� da F� (psi) har (in) Nb (lb) 24.0 1.00 2500 12.000 49883 r6N.bg =0 (AM/AN-) P c.N kF� d.N WqN'Fcp,NNb (Sec. 17.3.1 & Eq. 17.4.2.1 b) AN. (m') AN.. (In') ca,- (In) Te,N P.d,N 'P.,N V�.N Nb (lb) d ^bg (lb) 1764.00 1296.00 24.50 1.000 1.000 1.00 1.000 49883 0.70 47527 Pulir it Strength of Anchor In Tension (Sec. 17.4.4 fNpo = fY.,PNp = N ,P0.9f�ehda (Sec. 17.3.1, Eq. 17.4.3.1 & 17.4.3.5) 'P,P F� (psi) da (in) eb=3da (in) 0 ONpo (lb) 1.0 2500 1.13 3.38 0.70 5980 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925,847.3871 www.strangtie.com Anchor DesignerTM Software Version 3.0.7808.1 Steel8. Streng1h of Anchor In h r V- (lb) 091-t 0 Og-iOV- (Ib) 26550 1.0 0.65 17258 Company: Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page 516 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: cialonde@sdaevereft.com 9., Concrete Breakout Strength of Anchor in Shear f5ec. 17.6,21 Shear perpendicular to edge in x-direction: Vhx = min 17(1a/da)02v'daaavfxa,' S; 9dadfccaf1•51 (Eq. 17.5.2.2a & Eq. 17.5.2.2b) la (in) da (in) A. fc (psi) cat (in) Vhx (lb) 9.00 1.125 1.00 2500 25.00 56250 OVcbgx = 0 (Avc/Avca)'P-V%dvW.v'Ph,Nbx (Sec. 17.3.1 & Eq. 17.5.2,11b) Avc (in') Avco (in2) gec,V Wed,v 'I',v Y;; V Vbx (lb) 0 Oi/Op (lb) 1116.00 2812.50 1,000 0.896 1.000 1.443 56250 0.70 20206 Shear perpendicular to edge in y-direction: Vby = minj7(fa/da)02gda laJf'ccaf' 5; 9daNlf'cca1' 11 (Eq. 17.5.2.2a & Eq. 17.5.2,2b) !a (in) da (in) da f'., (psi) cai (in) Vby (Ib) 9.00 1.125 1 M 2500 16.39 29850 OVcbgy = 0 (Avc/Avro)' ea,v'Paavy';v'Ph,vVby (Sec. 17.3.1 & Eq. 17.5.2.1b) Avc (in2) Av- (in') 'lac,v 'Pd,v P,v 'I, v Vby (Ib) 0 OVcbgy (I b) 1117.44 1208.35 0.961 0.999 1.000 1.169 29850 0.70 21676 Shear parallel to edge in y-direction: Vbx = min(7(/e/da)024deaavfoc..i' 5; 9daJfccaf' 51 (Eq. 17.5.2.2a & Eq. 17.5.2.2b) to (in) da (in) A. fc (psi) ca, (in) Vbr (Ib) 9.00 1.125 1.00 2500 16.39 29850 OVcbgy = 0(2)(AVc/Avo)W-,v'Ped,vPgvWt,,VVbn (Sec. 17.3.1, 17.5.2.1(c) & Eq. 17.5.2.1b) Av. (in2) Avco (in2) `feo,v V' d,V 'Y,v 'ph,v Vbx (lb) 0 OVcbgy (Ib) 1117.44 1208.35 1M0 1.000 1.000 1.169 29850 0.70 45161 Shear parallel to edge in x-direction: Vby = min 17(1./da)"Vda.Iagfccaf' S; 9davf�caf1•51 (Eq. 17.5.2.2a & Eq. 17,5.2.2b) 1. (in) da (in) da fo (psi) cat (in) Vby (lb) 9.00 1.125 1'00 2600 16,33 29705 /d Vcbg.r = 0 (2)(Avr./Avco) Yac,v'PdvT,v'Ph vVby (Sec. 17.3.1, 17.5.2.1(c) & Eq. 17.5.2.1b) Avc (in2) Avca (in2) 'Pac,V 'Tdd.v `f ..v V'h,v Vby (lb) 0 OVchgx (lb) 1116.00 1200.50 1.000 1.000 1.000 1.167 29705 0.70 45103 10 Concrete Er�t� Strength of Anchor In Shear (5ec, 17,5 .) OVcp = Okc^b = Okcp(ANc/ANco)'Ped,NV'aN'f'cp,NNb (Sec. 17.3.1 & Eq. 17.5.3.1a) kcp AN. (in2) AN- (in2) Yad,N 'P N YpN Nb (Ib) 0 OVcp (lb) 2.0 600.25 1296.00 1.000 1.000 1,000 49883 0.70 32345 11. RQsUlt Interaction Qf Tensile an Shear Forces ISec. 17.$,] Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. S"c „i -, 5956 W. Las Positas Boulevard Pleasanton, CA 94586 Phone: 925.560 9000 Fax: 925.847.3871 www.strongtie.com II Anchor Designer TM Software Version 3.0.7808.1 Tension Factored Load, Nu. (lb) Steel 4532 Concrete breakout 9065 Pullout 4532 Company: Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page 6/6 Project: _ Walla Addition Address. 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com Design Strength, o% (lb) Ratio Status 33191 0.14 Pass 47527 0.19 Pass 5980 0.76 Pass (Governs) Shear Factored Load, Via (lb) Design Strength, OV (lb) Ratio Status Steel 286 17258 0.02 Pass T T Concrete breakout x+ 76 20206 0.00 Pass T Concrete breakout y- 984 21676 0.05 Pass II Concrete breakout y+ 76 45161 0.00 Pass II Concrete breakout x+ 568 45103 0.01 Pass Concrete breakout, - 0.05 Pass (Governs) combined Pryout 286 32345 0.01 Pass Interaction check N-10M Combined Ratio Permissible Status Sec. 17.6.1 0.76 0.00 75.8% 1.0 Pass 1 1/8"0 J- or L-Bolt, F1554 Gr. 36 with hef = 12.000 inch meets the selected design criteria. j 2. Warnings - Designer must exercise own judgement to determine if this design is suitable. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. .U„i- -r. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925,560,9000 Fax: 925.847.3871 www.strongtie.corn rrofect I me: vvalla Haaiuon Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed, 23 SEP 2021, 12:41PM Pole FootingEmbedded in Soil File:9371.ec6 SeaRware�'aAyrlgni L•NERCALC, INC 1983-207.0. BuiId:12.20.0 24 DESCRIPTION: Cantilever Post: Alternate Pole Footing 24" Dia. Code References Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Pole Footing Shape Circular Pole Footing Diameter. 24.0 in Calculate Min. Depth for Allowable Pressures No Lateral Restraint at Ground Surface Point Load Allow Passive . . ................ 150.0 pcf Max Passive , , , ............... 1,500.0 Psf Controlling Values 0 Governing Load Combination : +D+0.70E o Lateral Load 0.6888 k Moment 6,888 k-ft NO Ground Surface Restraint Soil Surface No lateral restraint Pressures at 1/3 Depth Actual 327.505 psf Allowable 327.674 psf N Minimum Required Depth 6.625 R Footing Base Area 3.142 ft"2 Maximum Soil Pressure 1.222 ksf Applied Loads Lateral Concentrated Load (k) Lateral Distributed Loads (klf) Vertical Load (k) D : Dead Load k k/ft 1.440 k Lr : Roof Live k k/ft 1.920 k L : Live k k/ft k S : Snow k k/ft 2.40 k W : Wind k k/ft k E : Earthquake 0,9840 k k/ft k H : Lateral Earth k k/ft k Load distance above TOP of Load above ground surface ground surface 10.0 ft ft BOTTOM of Load above ground surface ft Load Combination Results Forces @ Ground Surface Required Pressure at 113 Depth Son Increase Load Combination Loads - (k) Moments - (ft-k) Depth - (ft) Actual - (psf) Allow - (psf) Factor D Only 0.000 0.000 0.13 0.0 0.0 1.000 +D+Lr 0.000 0,000 0.13 0,0 0.0 1.000 +D+S 0.000 0.000 0.13 0.0 0.0 1.000 +D+0.750Lr 0,000 0.000 0.13 0.0 0.0 1,000 +D+0.750S 0.000 0.000 0,13 0.0 0.0 1.000 +0.60D 0.000 0.000 0.13 0.0 0.0 1.000 +D+0.70E 0.689 6.888 6.63 327.5 327.7 1.000 +D+0.750S+0.5250E 0.517 5.166 6,00 293.3 294.0 1000 +0.600+0,70E 0.689 6,888 6.63 327.5 327.7 1.000 rrolect i me: vvana Haaition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed 23 SEP 2021. 12 41 PM Pole FootingEmbedded in Soil File:9371.ec6 Soltwareaopynghl ENERCALG, INC 1903.242[I. BuiId:12.208.24 DESCRIPTION: Cantilever Post: Alternate Pole Footing 36" Dia. Code References Calculations per IBC 2018 1807.3, CBC 2019, ASCE 7-16 Load Combinations Used : ASCE 7-16 General Information Pole Footing Shape Circular Pole Footing Diameter ........... 36.0 in Calculate Min. Depth for Allowable Pressures No Lateral Restraint at Ground Surface Allow Passive .................. 150,0 Pcf Max Passive . ............... 1,500.0 Psf Point Load Controlling Values Governing Load Combination: +D+0.70E o Lateral Load 0.6888 k o Moment 6.888 k-ft NO Ground Surface Restraint Pressures at 1l3 Depth Soil Surface No lateral restraint Actual 280.737 Psf N Allowable 281.166 psf Nnimum Required Depth 5.625 ft Footing Base Area 7,069 ft^2 Maximum Soil Pressure 0.5432 ksf Applied Loads Lateral Concentrated Load (k) Lateral Distributed Loads (klf) Vertical Load (k) D : Dead Load k k/ft 1.440 k Lr : Roof Live k k/ft 1.920 k L : Live k k/ft k S : Snow k k!ft 2,40 k W : Wind k k/ft k E : Earthquake 0.9840 k k!ft k H : Lateral Earth k k/ft k Load distance above TOP of Load above ground surface ground surface 100 ft ft BOTTOM of Load above ground surface ft Load Combination Results Forces @ Ground Surface Required Pressure at 113 Depth Sod Increase Load Combination Loads - (k) Moments - (ft-k) Depth - (ft) Actual - (psf) Allow (psf) Factor D Only 0.000 0.000 0.13 00 0.0 1.000 +D+Lr 0.000 0.000 0.13 0.0 0.0 1.000 +D+S 0,000 0.000 0.13 0.0 0.0 1000 +D+0.750Lr 0.000 0.000 0.13 0.0 0.0 1,000 +D+0.750S 0.000 0.000 0.13 0.0 0.0 1.000 +0.60D 0.000 0.000 0.13 0.0 0.0 1000 +D+0.70E 0.689 6,888 5.63 280.7 2812 1.000 +0+0.750S+0 5250E 0.517 5.166 5.13 252.1 252.5 1.000 +0.60D+0.70E 0.689 6.888 5.63 280.7 281.2 1000 OL ��� p �� r � "' `I •ram ��U i� (�� �i11 r Ala, P r �, L �• �,. /i• 8 7s '/z,�'F- Ve/) zk s (zyF-vti) 71 2pc 8 �y /Va, Z i411 tic 1,�� 3, y h '(x l0 DF n/v, 2 HFNo , 2 bl 05 Zx f0 HF /Ve, Z � SO 3 , ti1) Y z z• l 00 Project Title: Walla Addition Engineer: . Chris Lalonde Project ID: SDA#9371� Project Descr:�' Printed. 28 SEP 2021. 9:01AM Wood Beam File:9371.ec6 Softwareocoynghi ENERCALC, INC. 1983-2020, Build:12.20,8.24 DESCRIPTION: BM#10: Beam Over New 12-0 SLGD CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 875.0 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 875.0 psi Ebend-xx 1,300.Oksi Fc - Prll 600.0 psi Eminbend - xx 470.Oksi Wood Species : Douglas Fir -Larch Fc - Perp 625.0 psi Wood Grade No.2 Fv 170.0 psi Ft 425.0 psi Density 31.210pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0 585) 0(0 781) S(0 975) ID(0.04) 6x10 Span = 12.0 ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Point Load : D = 0.5850, Lr = 0.780, S = 0.9750 k @ 6.0 ft, (RF) Uniform Load : D = 0.040 , Tributary Width =1.0 ft, (Wall) DESIGN SUMMARY +► = ■ Maximum Bending Stress Ratio = 0.80a 1 Maximum Shear Stress Ratio = 0.154 : 1 Section used for this span 6x10 Section used for this span 6x10 fb: Actual = 812.85 psi fv: Actual = 30.07 psi Fb: Allowable = 1,006.25psi Fv: Allowable = 195.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 6.000ft Location of maximum on span = 0.000 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0,119 in Ratio = 1206>=360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.238 in Ratio = 604>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V Cd C FN C i C r C m C t C L M fb Fb V fv F'v D Only 0.00 0.00 0,00 0.00 Length =12.0 It 1 0.493 0.105 0.90 1,000 1.00 1.00 1.00 1.00 1.00 2.68 388.57 787.50 0,56 1608 153.00 +D+Lr 1.000 1,00 1.00 1,00 1.00 1,00 0,00 0,00 0.00 0.00 Length = 12.0 ft 1 0.666 0.128 1.25 1.000 1.00 1.00 1.00 1.00 1.00 5.02 727.99 1093.75 0,95 2727 212.50 +D+S 1.000 1.00 1A0 1.00 1.00 1.00 0.00 0.00 000 0.00 Length = 12.0 ft 1 0.808 0.154 1.15 1,000 1.00 1.00 1.00 1.00 1.00 5.60 812.85 1006.25 1.05 30,07 195.50 +0+0.750Lr 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 12.0 ft 1 0.588 0.115 1.25 1.000 1.00 1.00 1.00 1.00 1.00 4.43 643.14 1093.75 0.85 24,47 212.50 +0+0.750S 1,000 1.00 1,00 1.00 1,00 1.00 0.00 000 0,00 0.00 Length = 12.0 ft 1 0,702 0.136 1.15 1 000 1.00 1,00 1.00 1.00 1,00 4.87 706.78 1006.25 0,93 2657 195.50 +0.60D 1000 1.00 1,00 1.00 1.00 1.00 0,00 000 0.00 0,00 Length = 12.0 ft 1 0.167 0.035 1.60 1.000 1.00 1.00 1.00 1,00 1.00 1.61 233.14 1400.00 0,34 9.65 272,00 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 71 Project Descr: Panted: 28 SEP 2021, 9:01AM Wood Beam File:9371.ec6 - Soflwarecopyrighi ENERCALC. Nr— 1983.X20, Build:12,20.8.24 DESCRIPTION: BM#10: Beam Over New 12-0 SLGD Overall Maximum Deflections Load Combination Span +D+S 1 Vertical Reactions Load Combination Overall MAXimum Overall MINimum D only +D+Lr +D+S +D+0.750Lr +D+0,750S +0.60D Lr Only S Only Max. "-" Defl Location in Span Load Combination 0.2382 6.044 Support notation : Far left is #1 Support 1 Support 2 1.088 1.088 0,488 0,488 0.600 0.600 0.990 0.990 1.088 1.088 0.893 0.893 0.966 0.966 0.360 0.360 0,390 0.390 0.488 0.488 Max. "+" Defl Location in Span 0,0000 0.000 Values in KIPS Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: > �r Printed 28 SEP 2021. 8:12AM Wood Beam File: g371.ec6 Software hI ENERCALC, INC. 19832020, BuiId:12.20.8.24 DESCRIPTION: BM#11: Covered Porch Ridge Beam CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 2400 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 1850 psi Ebend- xx 1800 ksi Fc - Prll 1650 psi Eminbend - xx 950ksi Wood Species : DF/DF Fc - Perp 650 psi Ebend- yy 1600ksi Wood Grade : 24F-V4 Fv 265 psi Eminbend - yy 850ksi Ft 1100 psi Density 31.21 pcf Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0 135)_Lr(0 13) S(0 225) D(0. 135) Lr(0 18) S(0 225) &5 5x11 875 5 5x11 875 Span =180ft Span =20ft Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loads Load for Span Number 1 Uniform Load : D = 0.1350, Lr = 0,180, S = 0.2250 , Tributary Width =1.0 ft, (RF) Load for Span Number 2 Uniform Load : D = 0.1350, Lr = 0.180, S = 0.2250 , Tributary Width =1.0 ft, (RF) DESIGN SUMMARY R • Maximum Bending Stress Ratio = 0.497.1 Maximum Shear Stress Ratio - 0.231 : 1 Section used for this span 5.5x11.875 Section used for this span 5.5x11.875 fb: Actual = 1,372.18psi fv: Actual = 70.52 psi Fb: Allowable = 2,760.00psi Fv: Allowable - 304.75 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 8.849ft Location of maximum on span = 17.095 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.377 in Ratio = 573 >=360 Max Upward Transient Deflection -0.129 in Ratio = 370>=360 Max Downward Total Deflection 0,626 in Ratio = 344>=180 Max Upward Total Deflection -0.215 in Ratio = 222>=180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V Cd C FN C i C r C m C t C L M Ib F'b V tv Fv D Only 0.00 0.00 0.00 0,00 Length = 18.0 ft 1 0.253 0.118 0,90 1.000 1.00 100 1.00 1,00 1.00 589 547.01 2160.00 1,22 28 11 238.50 Length = 2.0 ft 2 0,017 0,118 0.90 1.000 1.00 1,00 1.00 1,00 1.00 030 27,69 1665.00 0.15 28,11 238.50 +D+Lr 1.000 1.00 1.00 1.00 1.00 1.00 0,00 0,00 000 0.00 Length = 18.0 ft 1 0.402 0.187 1.25 1.000 1,00 1.00 1.00 1.00 1.00 13.00 1,207.15 3000.00 2.70 62.03 331.25 Length = 2.0 ft 2 0.026 0.187 1.25 1.000 1.00 100 1.00 1.00 1.00 0.66 61.11 2312,50 0,33 6203 331,25 +D+S 1,000 1.00 100 1.00 1,00 1.00 0,00 0,00 0,00 0,00 Length = 18.0 It 1 0.497 0.231 1.15 1.000 1.00 100 1.00 1.00 1.00 14.78 1,372.18 2760.00 307 7052 304.75 Length = 2.0 ft 2 0,033 0,231 1.15 1.000 1.00 1.00 1.00 1.00 1.00 0.75 69.47 2127,50 0,38 70,52 304.75 +0+0.750Lr 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed: 28 SEP 2021 8:12AM Wood Beam Fue:9371.ec6 Soflwarewpy t l:HBRCRLC. INC. 1983-2020, BuiId:12.20.0.24 DESCRIPTION: BM#11: Covered Porch Ridge Beam Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C FN C i CT C m C t C L M fb F'b V tv F'v Length = 18.0 ft 1 0.347 0.162 1.25 1.000 1.00 1.00 1.00 1.00 1.00 11.23 1,042.11 3000.00 2,33 53.55 331.25 Length = 2.0 ft 2 0.023 0.162 1.25 1.000 1.00 1.00 1.00 1.00 1.00 0.57 52.76 2312.50 0.29 53.55 331.25 +D+0.750S 1.000 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 18.0 ft 1 0.422 0.197 115 1.000 1.00 1.00 1.00 1.00 1.00 12.56 1,165.89 2760.00 2.61 59.91 304.75 Length = 2.0 ft 2 0.028 0.197 1.15 1.000 100 1.00 1.00 1.00 1,00 0.64 59.02 2127.50 0.32 59.91 304,75 +0.60D 1.000 1.00 1.00 1.00 1.00 1,00 0.00 0.00 0.00 0.00 Length =18.0 it 1 0,085 0.040 1.60 1.000 1.00 1.00 1.00 1,00 1.00 3.54 328.21 3840.00 0.73 16.87 424.00 Length = 2.0 ft 2 0.006 0.040 1.60 1.000 1.00 1.00 1.00 1.00 1.00 0.18 16.62 2960.00 0.09 16.87 424.00 Overall Maximum Deflections Load Combination Span Max. " " Defl Location in Span Load Combination Max. "+" Dell Location in Span +D+S 1 0.6263 9.050 0.0000 0.000 2 0.0000 9.050 +D+S -0.2153 2.000 Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 Support 3 Overall MAXimum 3.326 4.157 Overall MINimum 2.000 2.500 D Only 1.326 1.657 +D+Lr 2.926 3.657 +D+S 3.326 4.157 +D+0.750Lr 2.526 3.157 +D+0.750S 2.826 3,532 +0.60D 0.795 0,994 LrOnly 1.600 2.000 S Only 2.000 2.500 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: �C Printed: 28 SEP 2021, 8:13AM Wood Beam File: 9370,ec6 SnitwareCopyrighl ENERCAI.C, INC.1983-2020, BuiId:12.2.B.24 DESCRIPTION: BM#12: Covered Porch Horizontal Beam CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + 2400 psi E : Modulus of Elasticity Load Combination ASCE 7-16 Fb - 1850 psi Ebend- xx 1800ksi Fc • Prll 1650 psi Eminbend - xx 950ksi Wood Species : DF/DF Fc - Perp 650 psi Ebend- yy 1600ksi Wood Grade : 24F-V4 Fv 265 psi Eminbend - yy 850ksi Ft 1100 psi Density 31.21 pcf Beam Bracing : Beam is Fully Braced against lateral -torsional buckling D(1 2), 5 5x1'I 875 Span =180ft • M Applied Loads Beam self weight calculated and added to loads Point Load : D = 4.20 k @ 9.0 ft, (BM#11) DESIGN SUMMARY Service loads entered. Load Factors will be applied for calculations Maximum Bending Stress Ratio = 0.837' 1 Maximum Shear Stress Ratio Section used for this span 5.5x11.875 Section used for this span fb: Actual = 1,807.77psi fv: Actual Fb: Allowable = 2,160.00psi Fv: Allowable Load Combination D Only Load Combination Location of maximum on span = 9,000ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.000 in Ratio = 0 <360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.666 in Ratio = 324 -180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C Fn! C i Cr C m C t C L D Only Length = 18.0 ft 1 0.837 0.213 0.90 1.000 1.00 1.00 1.00 1.00 1.00 +0.60D 1.000 1.00 1.00 1.00 1.00 1.00 Length = 18.0 ft 1 0.282 0.072 1.60 1.000 1.00 1.00 1.00 1.00 1.00 Overall Maximum Deflections Load Combination Span Max. ' " Defl Location in Span Load Combination D Only 1 0.6661 9 066 Vertical Reactions Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 2.227 2.227 Overall MlNimum 1.336 1.336 Moment Values M fb 19.47 1,807.77 11,68 1,084.66 �Ormpml 0.213 : 1 5.5x11.875 50.84 psi = 238.50 psi D Only 17 015 ft Span # 1 Shear Values F'b V fv F'v Ho 0.00 0,00 0.00 2160.00 2.21 50,84 238.50 0,00 0.00 0,00 0.00 3840,00 1.33 30.50 424,00 Max. "+" Defl Location in Span 0,0000 0.000 Values in KIPS Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: 41r, Z Wood Beam DESCRIPTION: BM#12: Covered Porch Horizontal Beam Vertical Reactions Support notation : Far left is #1 Load Combination Support 1 Support 2 D Only 2,227 2.227 +0.60D 1,336 1.336 Printed: 28 SEP 2021, 8:13AM File: 9371.ec6 Softwareenpy"M ENERC_ALC, INC. 1963.2p20. Oulld:12.20.8.24 1.R-L Ili ( Yj ==] Values in KIPS Input Cells DeFl-non Lirnit Hrz span: Slope: Angle: Span: Trib Width: K le Flat Roof: Bending: Compression: Trib Bend: Trib Comp: 4l7. Rear Covered Porch Rafters 240 9 ft. USE: 2x8 HF No.2 4 12 Rxn: 371 Ibs Incised?: No S 25 24 7.91 47 15.81 18.4 Degrees 9.5 24 inches 1.0 9.5 DL Lr 15 20 14.23 18.97 4.74 6.32 28.46 37.95 9,49 12.65 Date: 1 9/28/20211 Job#19371 (3.9-3) (3.9-4) Bend: Comp: D/C L/ 2x4 Fails Checks Fails Fails 3.2 47 2x6 Fails Checks Fails Fails 1.3 183 CHECKS 2x8 Checks Checks Checks Checks 0.7 418 CHECKS 2x10 Checks Checks Checks Checks 0.5 869 CHECKS 2x12 Checks Checks Checksl Checks 0.4 1 1563 CHECKS 1 756 5 Checks Checks Checks Checks 0.4 328 CHECKS 1.7sx7.25 Checks Checks Checks Checks 0.2 751 CHECKS 1-75x9 Checks Checks Checks Checks 0.1 1689 CHECKS 1.75x11.875 Checks Checks Checks Checks 0.1 3298 CHECKS 1.75x14 Checks Checks Checks Checks 0.1 5405 CHECKS 175x16 Checks Checks Checks Checks 0.1 8068 2EC11 1,75x13 Checks Checks Checks Checks 0.0 11487 CHECKS 3.5x7.25 Checks Checks Checks Checks 0.1 1662 CHECKS 35x9_5 Checks Checks Checks Checks 0.1 3378 CHECKS 35x11.875 Checks Checks Checks Checks 0.0 6597 CHECKS 35x14 CheCkSj Checks Checks Checks 0.0 10810 CHECKS 3sx16 Checks Checks Checks Checks 0.0 16136 CHECKS 3 sxls Checks Checks Checks Checks 0.0 22974 Member 20 2x6 2x8 2x10 I 2x12 1.756.5 1,75x7 25 1 1.75x9,5 1 7501 874 1 75x14 1.75x16 1 75x18 Depth: 3.50 5.50 7 25 9.25 1L2.5 5 50 7 25 9.50 11.88 14.00 16.000 i3,000 Area: 5.250 8-250 10-875 13.875 16,875 9 625 12-683 16.625 20.781 24500 28,000 31.500 S(in^3): 3.063 T563 13.141 21.391 31.641 8823 15331 26,323 4L130 57167 74.667 94500 I: 5.4 20.8 47.6 98.9 178.0 24.3 55 5 125.0 244.2 400,2 5973 8505 R B 1 3.842 4.816 5.529 1 6,245 6.887 4 128 4 739 SA25 6.065 6-585 1 7.040 7 467 Material Properties Material Properties F b: 850 F_b: 2600 Member- 3, 5x7,25 3 5x9 5 3 5x14 3.5x16 3 5x18 F_c: 1300 HF No.2 F_c: 2510 LVL 2.0E Depth: 7500 9.500 14-000 16-000 18.000 E min 4.7E+05 E min 1.0E+06 Area: 26.250 33.250 r488 49000 56,000 63,000 E 1.3E+06 E 2.0E+06 Slin^3): 32,813 52-646 114.333 149,333 189000 W 92 PLF W 92 PLF r 123 0 250,1 800.3 1194 7 1701.0 Moment: 1041 lb`ft Momen 1041 Ib*ft R B 4,820 5.425 6.065 6.585 7040 7,467 C.-D C_M C t C_L 1,15 1-0 1.0 1-0 Bending C_F(x4) C_F(x6) C_F(x8) C_F(x10) C_F(x12) C_V(5.5) C_V(7.25) IC_V(9.5) V(11.87 C_V(14) C V(16) C V(18) 1.5 1.3 1.2 1.1 1A 1.1 1.1 1.0 1.0 1.0 1.0 0.9 Compression C_F (x4) C F (x6) C F (x8) C F (x10) C F (x12) 1 15 1 0 Li 1-0 10 1 1 1,0 1.0 1 C 10 0.1 C fu C i C r C P C T L0 110 1.15 1.0 1 fc 90 90 90 90 90 90 90 90 90 90 90 90 90 fbi 4077 1651 950 584 395 1415 815 474 304 218 167 132 381 F'bl 1686 1461 1349 1237 1124 3823 3682 3550 3443 3367 3307 3254 3665 Pc 1977 1719 1805 1719 1719 3651 3651 3319 3319 3319 3319 2988 3319 F'b2 0 0 0 G 0 0 0 0 0 0 0 0 0 E'rnln 4 70E+05 4.70E+05 4 70E r05 4,70E+05 4-70E+05 1-02E+06 1.02E+06 1.02E+06 1.02E+06 1.02E+06 1,02E+06 1.02E+06 1,02E+06 FcE! 365'e+02 9-02E+02 1.57E+03 155E+03 3.77E+03 1.95E+03 3.39E+03 5.82E+03 9.09E+03 1 26E+04 1-65E+04 2 09E+04 3,63E F03 -FbE 39213 24321 18450 14461 11390 71597 5431S 41451 33161 28127 24612 21877 52505 ,Checks: 1(3 9-3) 3,211 1.258 0,750 0 492 0.362 0, 389 0 2 0,136 0 090 0.066 0.052 0.042 0.107 4�3 9-41 1 14E-02 4 61E-03 2 65E-03 i 63E-03 1 10E-03 3 91E-04 2 25E-04 1 31E-04 8 38E-05 5 03E-05 4 62E-05 3-65F-05 5.25E-05 Bending: 2.42E+00 1. 13E r00 704E-01 4.726!71 351E-01 3,70E-01 2.21E-01 134E-01 8.32E-02 6-49E-02 5.06E-02_.j 4A6c02 104E-01 C.mpresslan: 4-55E-02 5 23E-02 4,99E-02 5.23E-02 •.`!!'i: 2 4'oE iR 2,46E•G2 2 71E-02 2 71E-02 2-71E-02 2 71E-02 3.01E-02 2 71E-02 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Wood Beam DESCRIPTION: BM#14.1: Porch Ridge Header CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + Load Combination ASCE 7-16 Fb Fc Pril Wood Species Douglas Fir -Larch Fc Perp Wood Grade No.2 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling Applied Loads Beam self weight calculated and added to loads Point Load : D = 3.40 k @ 1.50 ft, (BM#11) DESIGN SUMMARY Printed: 28 SEP 2021 d 26AM Fiie:9371.ecS 9pRw0copytight ENERCAtC, INC. t993.2020. SWIdAZA8.24 875.0 psi E : Modulus of Elasticity 875.0psi Ebend-xx 1,300.Oksi 600.0 psi Eminbend - xx 470.Oksi 625.0 psi 170.0 psi 425.0 psi Density 31.210pcf I -J 4x 10 j, Span = 6 Oft Service loads entered Load Factors will be applied for calculations Maximum Bending Stress Ratio = 0.977 1 Maximum Shear Stress Ratio Section used for this span 4x10 Section used for this span fb: Actual = 923.11 psi fv: Actual Fb: Allowable = 945.00psi Fv: Allowable Load Combination D Only Load Combination Location of maximum on span = 1.511 ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.000 in Ratio = 0 <360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.063 in Ratio = 1149>=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C FIV C i C r C m C t C L D Only Length = 6.0 ft 1 0.977 0.777 0.90 1.200 1.00 1.00 1.00 1.00 1.00 +0.60D 1.200 1.00 1.00 1.00 1,00 1.00 Length = 6.0 ft 1 0.330 0.262 1.60 1.200 1.00 1.00 1.00 1,00 1,00 Overall Maximum Deflections Load Combination Span Max. "" Defl Location in Span Load Combination D Only 1 0,0627 2.672 Vertical Reactions Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 2,571 0.871 Overall MINimum 1.543 0.523 0.777 : 1 4x10 118.87 psi 153.00 psi D Only 0.000 ft Span # 1 Moment Values Shear Values M fb Fb V fv F'v 0.00 0.00 0.00 0.00 384 923.11 945.00 2.57 118.87 15300 0.00 0.00 0.00 0.00 2.30 553.87 1680.00 1.54 71.32 272.00 Max. '+' Defl Location in Span 0.0000 0.000 Values in KIPS Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed: 28 SEP 2021, 8:26AM Wood Beam FIle:937.ec6 Software DM ! ENERCALC, INC. 1993-2020, BuiId:12.20.8.24 DESCRIPTION: BM#14,1: Porch Ridge Header Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 C Only 2,571 0.871 +0.60D 1.543 0.523 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Wood Beam DESCRIPTION: BM#14.2: Porch Ridge Header CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + Load Combination ASCE 7-16 Fb - Fc - Prll Wood species ; Hem -Fir Fc - Perp Wood Gi aciP : No.2 Fv Ft Beam Bracing : Beam is Fully Braced against lateral -torsional buckling ot3 it Applied Loads Beam self weight calculated and added to loads Point Load : D = 3.40 k @ 1.50 ft, (BM#11) DESIGN SUMMARY 600 Span = 6 0 ft Printed: 28 SEP 2021, 8:26AM File: 9371.ec6 Software ,=ynght ENERCALC. INC 1983-8�'d[}, Build:12.20.8.24 a: 675.0 psi E : Modulus of Elasticity 675.0 psi Ebend- xx 1,100.0 ksi 500.0 psi Eminbend - xx 400.Oksi 405.0 psi 140.0 psi 350.0 psi Density 26.840 pcf I Service loads entered. Load Factors will be applied for calculations Maximum Bending Stress Ratio = 0.9191 Maximum Shear Stress Ratio Section used for this span 6x10 Section used for this span fb: Actual = 558.26psi fv: Actual Fb: Allowable = 607.50psi Fv: Allowable Load Combination D Only Load Combination Location of maximum on span = 1.511 ft Location of maximum on span Span # where maximum occurs = Span # 1 Span # where maximum occurs Maximum Deflection Max Downward Transient Deflection 0.000 in Ratio = 0 <360 Max Upward Transient Deflection 0,000 in Ratio = 0 <360 Max Downward Total Deflection 0.044 in Ratio = 1648 >=180 Max Upward Total Deflection 0,000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Segment Length Span # M V C d C FIV C i Cr C m C t C L D Only Length = 6.0 it 1 0.919 0.586 0.90 1.000 1.00 1.00 1.00 100 1.00 460D 1.000 1.00 1.00 1.00 1.00 1.00 Length = 6.0 ft 1 0.310 0.198 1.60 1.000 1.00 1.00 1.00 1.00 1.00 Overall Maximum Deflections Load Combination Span Max, "" Defl Location in Span Load Combination D Only 1 0.0437 2.672 Vertical Reactions Support notation: Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 2.579 0.879 Overall MINimum 1.548 0 528 0.586 : 1 6x10 73.82 psi = 126.00 psi D Only 0.000 ft = Span # 1 Moment Values Shear Values M fb F'b V fit Fv 0.00 0.00 0.00 0.00 3.85 558,26 60T50 2.57 73.82 126.00 0.00 0.00 0.00 0.00 2.31 334.96 1080.00 1.54 44.29 224.00 Max. "+" Defl Location in Span 0.0000 0.000 Values in KIPS Wood Beam DESCRIPTION: BM#14.2: Porch Ridge Header Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr: Printed: 28 SEP 2021, 8:26AM F7 9371.ec6 ` - Sortwara[�opyrghl ENEFtCA! G INC. 1983.20i0, Build:12.20 8.24 1; Vertical Reactions Support notation : Far left is #1 Values in KIPS Load Combination Support 1 Support 2 D Only 2.579 0.879 i0.60D 1.548 0 528 Project Title: Walla Addition Engineer: Chris Lalonde Project ID: SDA#9371 Project Descr:IGr p Wood Beam DESCRIPTION: BM#15: House Roof Ridge Beam CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set: ASCE 7-16 Material Properties Analysis Method: Allowable Stress Design Fb + Load Combination ASCE 7-16 Fb - Fc - Prll Wood Sper:ies ; Hem -Fir Fc - Perp Wood Crane No.2 Fv Ft Beam Bracing Beam is Fully Braced against lateral -torsional buckling D(0 105) Lr(0 14) S(0 175) 2x10 Span =7.0ft Printed: 29 SEP 2021, 9:06AM File: 9371.ec6 Software,xQprngnl ENERCALC, INC. t98&2020. Build:12,20.8.24 o: 850.0 psi 850.0 psi 1, 300.0 psi 405.0 psi 150.0 psi 525.0 psi E : Modulus of Elasticity Ebend- xx 1,300.0 ksi Eminbend -xx 470.Oksi Density 26.840pcf Applied Loads Service loads entered. Load Factors will be applied for calculations Beam self weight calculated and added to loads Uniform Load : D = 0.1050, Lr = 0.140, S = 0.1750 , Tributary Width = 1.0 ft, (RF) DESIGN SUMMARY e : ■ Maximum Bending Stress Ratio = 0.9031 Maximum Shear Stress Ratio = 0.484 :1 Section used for this span 2x10 Section used for this span 2x10 fb: Actual = 970.99psi fv: Actual = 83.51 psi Fb: Allowable = 1,075.25psi Fv: Allowable - 172.50 psi Load Combination +D+S Load Combination +D+S Location of maximum on span = 3.500ft Location of maximum on span = 6,234 ft Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1 Maximum Deflection Max Downward Transient Deflection 0.074 in Ratio = 1136> 360 Max Upward Transient Deflection 0.000 in Ratio = 0 <360 Max Downward Total Deflection 0.119 in Ratio = 703 >=180 Max Upward Total Deflection 0.000 in Ratio = 0 <180 Maximum Forces & Stresses for Load Combinations Load Combination Max Stress Ratios Moment Values Shear Values Segment Length Span # M V C d C Fri/ C i C r C m C t C L M fb F'b V N Fv D Only 0Z 0.00 0.00 0.00 Length = 7.0 ft 1 0.439 0,236 0.90 1,100 1,00 1.00 1.00 1.00 1.00 0.66 369.68 841.50 0.29 31.79 135.00 +O+Lr 1,100 1.00 1.00 1.00 1,00 1.00 0.00 0.00 0.00 0,00 Length = 7.0 ft 1 0,728 0.390 1,25 1.100 1.00 1.00 1.00 1.00 1.00 1.52 850.73 1168.75 0.68 73.17 187.50 +D+S 1.100 1Z 1.00 1.00 1.00 1.00 0.00 0,00 0.00 0.00 Length = 7.0 ft 1 0.903 0.484 1.15 1.100 1.00 1,00 1.00 1.00 100 1,73 970.99 1075,25 0.77 83.51 172,50 +D+0.750Lr 1100 1.00 1.00 100 1.00 1.00 0.00 0.00 0.00 0.00 Length = 7.0 ft 1 0,625 0.335 1.25 1.100 1.00 1.00 1,00 1.00 1.00 1.30 730.46 1168.75 0,58 62.82 18T50 +0+0.750S 1,100 1,00 1.00 1,00 1,00 1.00 0.00 0,00 0.00 0.00 Length = TO ft 1 0.763 0,409 1.15 1.100 1.00 1,00 1.00 1.00 1,00 1.46 820.66 1075.25 0,65 70.58 172.50 +0.601) 1-100 1.00 1,00 1.00 1.00 1.00 0.00 0.00 0.00 0.00 Length = 7.0 ft 1 0.148 0,079 1.60 1,100 1.00 1,00 1.00 1.00 1.00 0.40 221.81 1496.00 0.18 19.08 240.00 Project Title: Walla Addition Engineer: Chris Lalonde Project IDS SDA#9371 Project Descr: Wood Beam DESCRIPTION: BM#15: House Roof Ridge Beam Overall Maximum Deflections Load Combination Span Max. " " Defl Location in Span Load Combination +D+S 1 0.1194 3.526 Vertical Reactions Support notation : Far left is #1 Load Combination Support 1 Support 2 Overall MAXimum 0.989 0.989 Overall MINimum 0.613 0.613 D Only 0,377 0,377 +D+Lr 0.867 0.867 +D+S 0.989 0.989 +D+0,750Lr 0.744 0.744 +D+0.750S 0.836 0.836 +0.60D 0.226 0.226 Lr Only 0.490 0.490 S Only 0.613 0.613 Printed 28 SEP 2021. 9 06AM File: 9371.ec6 Software copynght EPiERCALC, INC, 1983-2020, Build:12.20.8.24 Max. "+" Defl Location in Span 0,0000 0.000 Values in KIPS 4ir1 t-71�'►l �f�►� Anchor Designer"' { Software =r. Version 3.0.7808.8 1APraject intormation Customer company: Customer contact name: Customer e-mail: Comment: 2_._Input_Data 8 Arschor Parameters General Design method:ACI 318-14 Units: Imperial units Anchor Information: Anchor type: Cast -in -place Material: AB Diameter (inch): 0.500 Effective Embedment depth, her (inch): 12.000 Anchor category: - Anchor ductility: Yes hmin (Inch): 13.88 Cmin (Inch): 3.00 Smin (inch): 3.00 Company Structural Design Associates Date 9/23/2021 Engineer: Chris Lalonde Page 1/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com Recommended Anchor Anchor Name: PAB Pre -Assembled Anchor Bolt - PAB4 (1/2" 0) Project description: Location: 10406 226th PL SW Edmonds, WA 98020 Fastening description: Base Material Concrete: Normal -weight Concrete thickness, h (inch): 18.00 State: Cracked Compressive strength, fc (psi): 2500 4V.,v: 1.0 Reinforcement condition: B tension, B shear Supplemental reinforcement: Not applicable Reinforcement provided at corners: No Ignore concrete breakout in tension: No Ignore concrete breakout in shear: No Ignore Edo requirement: No Build-up grout pad: No Base Plate Length x Width x Thickness (inch): 16.00 x 16.00 x 0.25 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility, Simpson Strong-T�.a Coinpany Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com E.711►�]�.`�•�►■ Anchor Designer"' h' Software Version 3.0.7808.8 Load and Geometry Load factor source: ACI 318 Section 5.3 Load combination: not set Seismic design: No Anchors subjected to sustained tension: Not applicable Apply entire shear load at front row: No Anchors only resisting wind and/or seismic loads: No Strength level loads: Nuu [Ib]: 0 Vum Jib]: 0 Vm (lb): -984 M ■ Itt-lb]: 9840 Muy (tt-li7]: 0 iNur [ft-Ib]: 0 <Figure 1> 0 ft-lb M 9840 ft-lb f. 0 Ib Company: Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page: 2/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com o i� .4 0 ft-lb 14 lb Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpson Strong -Tie Company Inc; 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www strongtie.com Anchor Designer"' Software Version 3.0.7808.8 <Figure 2> Company: Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page: 3/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Simpsan Strong -Tie Company Inc, 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com 4//, Y Anchor DesignerT"^ . ,. Software Version 3.0.7808.8 '4 Company: Structural Design Associates TlDate7: 9/23/2021 Engineer: Chris Lalonde Page: 4/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com 3. Resulting Anchor Forces Anchor Tension load, Shear load x, Shear load y, Shear load combined, Nua (lb) Vuax (Ib) Vuay (lb) J(V-)'+(Vuay)Z (lb) 1 0.0 -37.8 -283.8 286.4 2 4279.6 37.8 -283.8 286.4 3 4279.6 37.8 -208.2 211.6 4 0.0 -37.8 -208.2 211.6 Sum 8559.3 0.0 -984.0 995.8 Maximum concrete compression strain (%o): 0.12 <Figure 3> o� 3 Maximum concrete compression stress (psi): 506 Resultant tension force (lb): 8559 Resultant compression force (lb): 8559 Eccentricity of resultant tension forces in x-axis, e'Nx (inch): 0.00 Eccentricity of resultant tension forces in y-axis, e'Ny (inch): 0.00 Eccentricity of resultant shear forces in x-axis, e'vx (inch): 0.00 Eccentricity of resultant shear forces in y-axis, e'vy (inch): 0.00 Y 01 02 4. Steel Strength of Anchor in Tension (Seg.17.4.11 Nsa (lb) 0 ON- (lb) 8235 0.75 6176 -5 Con -n to Breakout Strength of Anchor in Tension {Sec.17.4_2� Nb = 16A.4f�herbi3 (Eq. 17.4.2.2b) A. f. (psi) her (In) Nb (lb) 1.00 2500 12.000 50318 ^bg =0 (AWIANco) VJec,N'Fed,NVEC,NW�p,NNb (Sec. 17.3.1 & Eq. 17.4.2.1b) ANc (in2) Amo (in2) Ca,min (In) PegN %d,N %,N Vcp,N Nb (lb) 0 ONcbg (lb) 1893.75 1296.00 24.50 1.000 1.000 1.00 1.000 50318 0.70 51468 6. Pullout Strength of Anchor in Tension (Sec. 17.4.3) ONpn = OVIY,PNp = 0%,P8Abrgf� (Sec. 17.3.1, Eq. 17.4.3.1 & 17.4.3.4) VjG,P Ab g (in2) f� (psi) 0 ONpn (lb) 1.0 1.57 2500 0.70 21994 Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. Sirnrson SCror""' I e Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Anchor Designer"' Software Version 3.0.7808.8 B. Steel Strength of Anchor in Shear [Sec. 17.5.1 j V.. (lb) r%igrouf 0 OgroutoVsa (lb) 4940 1.0 0.65 3211 Company: Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page. 5/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail: clalonde@sdaeverett.com 9. Concrete Breakout Strength of Anchor in Shear (Sec.17.6.2] Shear perpendicular to edge in y-direction: Vby = minj7(le/da)124da laqfcca,7 5; 9A.4f.ca,' SI (Eq. 17.5.2.2a & Eq. 17.5.2.2b) le (in) da (in) Aa fc (psi) Ca, (in) Vby (lb) 4-00 0.500 1.00 2500 16.39 24883 OVcbgy = 0 (Avc/Avco)'Pa,V'Pad,V9e,v'Yh,VVby (Sec. 17.3.1 & Eq. 17.5.2.1b) Avc (in2) Avco (InZ) 'Pec,v Vad,V P.,V 'Ph,V Vby (lb) 0 OVcbgy (lb) 1117.44 1208.35 0.961 0.999 1.000 1.169 24883 0.70 18070 Shear perpendicular to edge in x-direction: Vbx = minl7(le/da)0-24d.A.gfcCa,' S; 9Aa4fcCa,' SI (Eq. 17.5.2.2a & Eq. 17.5.2.2b) le (in) da (in) da fc (psi) Cal (in) Vbx (lb) 4.00 0.500 1.00 2500 25.00 46890 OVcbgx = 0 (Avc/Avco) y`ec,vVed,V'Pc,v'Ph,vVbx (Sec. 17.3.1 & Eq. 17.5.2.1 b) Avc (in2) Av.. (in2) %P ,v 1Ped,V TC,V Vh,V Vbx (lb) 0 OVcbgx (Ib) 1116.00 2812.50 1.000 0.896 1.000 1.443 46890 0.70 16844 Shear parallel to edge in y-direction: Vbx = min 17(le/da)1.24d.A.4F .,1-5; 9Aa4fXai'•SI (Eq. 17.5.2.2a & Eq. 17.5.2.2b) le (in) da (in) Aa fc (psi) Ca, (in) Vbx (lb) 4.00 0.500 1.00 2500 16.39 24883 OVcbgy = 0 (2)(Avc/Avco)' Pec,V'Yed,V'Pc,VTh,VVbx (Sec. 17.3.1, 17.5.2.1(c) & Eq. 17.5.2.1b) Avc (in2) Avc. (in2) 'Pec,v Y'ad,v %,v Vh,v Vbx (lb) 0 oVcbgy (lb) 1117.44 12GUS 1.000 1-000 1.000 1.169 24883 0-70 37646 Shear parallel to edge in x-direction: Vby = minj7(/e/da)02gd.A.gfcca,15; 9Aa4fcca,' 51 (Eq. 17.5.2.2a & Eq. 17.5.2.2b) /a (in) da (in) Aa fc (psi) cal (in) Vby (lb) 4.00 0.500 1.00 2500 16.33 24762 o Vcbgx = 0 (2)(Avc/Avco)'Pec,V'Ped,v'Pc,v Wh,vVby (Sec. 17.3.1, 17.5.2.1(c) & Eq. 17.5.2.1 b) Avc (in2) Avco (in2) 'Pec,v �Yed,V VqV Vh,V Vby (lb) 0 OVcbgx (lb) 1116.00 1200.50 1.000 1.000 1.000 1.167 24762 0.70 37598 10. Concrete Pryout Strength of Anchor in Shear (Sec. 17.5.31 OVcp = OkcpNcb = Okcp(ANcI ANco) VPed,N V'c,N'Pcp,NNb (Sec. 17.3.1 & Eq. 17.5.3.1 a) kcp ANc (in2) ANco (in2) Ped,N :xc,N VPcp,N Nb (lb) 0 OVcp (lb) 2.0 637.56 1296.00 1.000 1.000 1.000 50318 0.70 34655 11. Results Interaction of Tensile and Shear Forces (Sec. 17.6- Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility, Simpson Strong -Tin Company Inc. 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925.560.9000 Fax: 925.847.3871 www.strongtie.com Tension Anchor Designer TM Software Version 3.0.7808.8 Company: Structural Design Associates Date: 9/23/2021 Engineer: Chris Lalonde Page: 6/6 Project: Walla Addition Address: 3006 Rucker Avenue Everett, WA 98201 Phone: (425)-339-0293 E-mail. clalonde@sdaeverett.com Factored Load, Naa (lb) Design Strength, ONE (lb) Ratio Status Steel 4280 6176 0.69 Pass (Governs) Concrete breakout 8559 51468 0.17 Pass Pullout 4280 21994 0.19 Pass Shear Factored Load, Via (lb) Design Strength, OVn (lb) Ratio Status Steel 286 3211 0.09 Pass (Governs) T Concrete breakout y- 984 18070 0.05 Pass T Concrete breakout x- 76 16844 0.00 Pass II Concrete breakout y+ 76 37646 0.00 Pass II Concrete breakout x+ 568 37598 0.02 Pass Concrete breakout, - - 0.05 Pass combined Pryout 286 34655 0.01 Pass Interaction check N a/0N V a/OV Combined Ratio Permissible Status Sec. 17.6..1 0.69 0.00 69.3% 1.0 Pass PAB4 (1/2"0) with hef = 12.000 inch meets the selected design criteria. 12. Warnings - Designer must exercise own judgement to determine if this design is suitable. Input data and results must be checked for agreement with the existing circumstances, the standards and guidelines must be checked for plausibility. zlmpson Sbonq T:e Ca,rTary Inc 5956 W. Las Positas Boulevard Pleasanton, CA 94588 Phone: 925,560,9000 Fax: 925.847.3871 www,strongtie.com