Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-0918_Manufacturer_Specifications_and_Installation_Instructions_7.24.2023_7.46.31_AM_3683423
Air Conditioning & Heating Standard Features • Energy -Efficient Compressor • Copper tube/ enhanced aluminum fin coil-5mm diameter • Factory -installed filter drier • Fully charged for 15' of tubing length • Service valves with sweat connections and easy -to -access gauge ports • Contactor with lug connection • Ground lug connection • AHRI Certified • ETL Listed GSXN3 ENERGY -EFFICIENT SPLIT SYSTEM AIR CONDITIONER 13.4 SEER2 / 1 Y2 TO 5 TONS Contents Nomenclature ........................................ 2 Product Specifications ........................... 3 Expanded Cooling Data ......................... 4 Wiring Diagrams ................................. 20 Dimensions .......................................... 22 Accessories .......................................... 22 Cabinet Features • Removable grille -style top design compliant with UL 60335-2-40 • Venturi for increased velocity of airflow • Heavy -gauge galvanized -steel cabinet • Attractive Architectural Gray powderpaint finish with 500-hour salt -spray approval • Steel louver coil guard • Rust -resistant coated screws • Single -panel access to controls with space provided for field -installed accessories 10 PARTS F L COMPANY WIT. COMPANYWITN LIMITED C \�I US QUALITY SYSTEM ENVIRONMENTAL SYSTEM CERTIFIED BY DNV GL CERTIFIED BY DNV GL ` YEAR WARRANTY'ISO goal =ISO 14001= 1 Intertek * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited BBB" Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-GSXN3 www.goodmanmfg.com 12/22 NOMENCLATURE G S X N 3 N 36 1 0 ** 1 2 3 4 5 6 7,8 9 10 11,12 Brand Engineering G Goodman® Brand Major/Minor Revisions A- Initial Release B- 1st Revision Product Category Variation S Split System Electrical Unit Type 1 208/230 V, 1 Phase, 60 Hz X Condenser Z Heat Pump Nominal Capacity 18-1.5 Ton 42- 3.5 Tons Feature 24- 2.0 Tons 48- 4.0 Tons N Value H Enhanced 30- 2.5 Tons 60- 5.0 Tons B Classic C Premium 36-3.OTons M Multi -Family V Ultimate Sales Region SEER2 N North 13.4- 13.7 = 3 16.6- 17.5 = 7 S Southeast & North 13.8- 14.5 = 4 17.6- 18.5 = 8 0 All Regions 14.6- 15.5 = 5 18.6- 19.5 = 9 15.6- 15.5 = 6 19.6 + = 0 2 www.goodmanmfg.com SS-GSXN3 PRODUCT SPECIFICATIONS CAPACITIES Nominal Cooling (BTU/h) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 Decibels (dBA) 73.0 73.0 76.0 71.0 70.0 74.0 74.0 COMPRESSOR RLA 6.1 8.4 12.1 14.1 17.7 18.5 25.6 LRA 35.1 41.2 55 87.4 110.2 124 150 Stage Single Single Single Single Single Single Single Type Rotary Rotary Rotary Scroll Scroll Scroll Scroll CONDENSER FAN MOTOR Motor Type PSC PSC PSC PSC PSC PSC PSC Horsepower (RPM) 1/8 1/8 1/6 1/6 1/6 1/4 1/4 FLA 0.70 0.70 0.95 0.95 0.95 1.30 1.30 REFRIGERATION SYSTEM Refrigerant Line Size' Liquid Line Size ("O.D.) %" W, 3W, 3W, %" W, 3W, Suction Line Size ("O.D.) 33/" %" %" %" 1%e' 1'/s" 1'/s" Refrigerant Connection Size Liquid Valve Size ("O.D.) %" W, 3W, 3W, %" W, 3W, Suction Valve Size ("O.D.) 4 s 3Y Y Y 3/8" W �8 Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat Refrigerant Charge 65 71 78 71 115 120 130 ELECTRICAL DATA Voltage(60 Hz) 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 208/230-1 Minimum Circuit Ampacity2 8.3 11.2 16.1 18.6 23.1 24.4 33.3 Max. Overcurrent Protection 3 15 15 25 30 40 40 50 Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253 Electrical Conduit Size %" or %" /:" or %" %" or Y."%" or %" %" or W %" or W %" or %" EQUIPMENT WEIGHT (LBS) 117 125 128 153 188 215 227 SHIP WEIGHT (LBS) 130 138 143 168 203 235 247 Line sizes denoted for 25' line sets, tested and rated in accordance with AR Standard 210/240. For other line set lengths or sizes, refer to the Installation Instructions and/or the Long Line Set Applications guide. ' Installer will need to supply to Y." adapters for suction line connections. 3 Installer will need to supply Na" to 1%" adapters for suction line connections. ° Unit is factory charged with refrigerant for 15' of %" liquid line. System charge must be adjusted per the Final Charge Adjustment procedure found in the Installation Instructions. Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes a Must use time -delay fuses or HACR-type circuit breakers of the same size as noted. Notes Always check the S&R plate for electrical data on the unit being installed. SS-GSXN3 www.goodmanmfg.com uq 0 0 o_ 3 Cu 3 amp' 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE C MBh 17.5 17.8 18.3 - 17.4 17.6 18.1 - 16.9 17.2 17.7 - 16.1 16.4 16.9 - 15.2 15.4 16.0 - 14.3 14.6 15.1 - S/T 0.61 0.54 0.41 0.61 0.54 0.42 0.64 0.57 0.44 0.65 0.58 0.46 1.00 0.60 0.48 1.00 0.65 0.53 AT 19 18 14 19 17 14 20 18 14 19 17 14 19 17 14 20 18 15 520 kW 1.12 1.12 1.12 1.25 1.24 1.24 1.38 1.38 1.38 1.53 1.53 1.53 1.70 1.70 1.70 1.89 1.89 1.89 Amps 4.1 4.1 4.1 4.7 4.6 4.6 5.3 5.3 5.3 6.0 6.0 5.9 6.7 6.7 6.7 7.6 7.6 7.6 HiPR 235 236 238 272 273 275 311 312 313 352 353 355 397 398 400 445 446 447 Lo PR 121 122 125 128 129 132 134 136 139 140 141 144 145 146 149 151 153 156 MBh 17.9 18.1 18.6 17.7 18.0 18.5 17.3 17.5 18.0 16.5 16.7 17.2 15.5 15.8 16.3 14.7 14.9 15.4 S/T 0.64 0.57 0.45 0.65 0.58 0.46 0.67 0.60 0.48 0.69 0.62 0.50 1.00 0.64 0.52 1.00 0.69 0.56 AT 18 16 13 18 16 13 18 17 13 18 16 13 18 16 12 19 17 14 70 600 kW 1.13 1.13 1.13 1.25 1.25 1.25 1.39 1.39 1.39 1.54 1.54 1.54 1.71 1.70 1.70 1.90 1.90 1.90 Amps 4.1 4.1 4.1 4.7 4.7 4.7 5.3 5.3 5.3 6.0 6.0 6.0 6.8 6.7 6.7 7.6 7.6 7.6 HiPR 238 239 240 274 275 277 313 314 316 355 356 357 399 400 402 447 448 450 Lo PR 123 125 128 130 132 135 137 138 141 142 143 146 147 149 152 154 155 158 MBh 18.3 18.5 19.0 18.1 18.4 18.9 17.7 17.9 18.4 16.9 17.1 17.6 15.9 16.2 16.7 15.1 15.3 15.8 S/T 0.65 0.58 0.45 0.65 0.58 0.46 0.68 0.61 0.48 1.00 0.62 0.50 1.00 0.64 0.52 1.00 0.69 0.57 AT 17 15 12 17 15 12 17 16 12 17 15 12 17 15 11 18 16 13 675 kW 1.13 1.13 1.13 1.26 1.26 1.25 1.40 1.39 1.39 1.54 1.54 1.54 1.71 1.71 1.71 1.91 1.90 1.90 Amps 4.1 4.1 4.1 4.7 4.7 4.7 5.3 5.3 5.3 6.0 6.0 6.0 6.8 6.8 6.8 7.7 7.7 7.7 HiPR 240 241 243 277 278 279 315 316 318 357 358 360 402 403 404 449 450 452 Lo PR 126 127 130 133 134 137 139 141 144 145 146 149 150 151 154 156 158 161 MBh 17.5 17.8 18.3 19.1 17.4 17.6 18.1 18.9 16.9 17.2 17.7 18.5 16.1 16.4 16.9 17.7 15.2 15.4 16.0 16.7 14.3 14.6 15.1 15.9 S/T 0.73 0.66 0.53 0.4 0.73 0.66 0.54 0.4 1.00 0.68 0.56 0.4 1.00 0.70 0.58 0.4 1.00 0.72 0.60 0.5 1.00 0.77 0.65 0.5 AT 24 22 18 14 24 22 18 14 24 22 18 15 24 22 18 14 23 21 18 14 24 23 19 15 520 kW 1.12 1.12 1.12 1.1 1.24 1.24 1.24 1.3 1.38 1.38 1.38 1.4 1.53 1.53 1.53 1.5 1.70 1.70 1.69 1.7 1.89 1.89 1.89 1.9 Amps 4.1 4.1 4.1 4.1 4.6 4.6 4.6 4.7 5.3 5.3 5.3 5.3 6.0 6.0 5.9 6.0 6.7 6.7 6.7 6.7 7.6 7.6 7.6 7.6 HiPR 235 236 238 242.2 272 273 275 279.0 311 312 314 317.6 352 353 355 359.1 397 398 400 403.9 445 446 448 451.7 Lo PR 121 122 125 130.2 128 129 132 137.4 134 136 139 143.8 140 141 144 149.1 145 146 149 154.4 151 153 156 161.0 MBh 17.9 18.1 18.6 19.4 17.7 18.0 18.5 19.3 17.3 17.5 18.0 18.8 16.5 16.7 17.3 18.0 15.5 15.8 16.3 17.1 14.7 14.9 15.4 16.2 S/T 0.76 0.69 0.57 0.4 0.77 0.70 0.57 0.4 1.00 0.72 0.60 0.5 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 1.00 0.68 0.6 AT 22 21 17 13 22 20 17 13 23 21 17 13 22 20 17 13 22 20 17 13 23 21 18 14 75 600 kW 1.13 1.13 1.13 1.13 1.25 1.25 1.25 1.26 1.39 1.39 1.39 1.40 1.54 1.54 1.53 1.54 1.70 1.70 1.70 1.71 1.90 1.90 1.90 1.91 Amps 4.1 4.1 4.1 4.1 4.7 4.7 4.7 4.7 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.0 6.8 6.7 6.7 6.8 7.6 7.6 7.6 7.7 HiPR 238 239 240 244.6 275 276 277 281.4 313 314 316 319.9 355 356 357 361.5 400 401 402 406.2 447 448 450 454.0 Lo PR 123 125 128 132.6 130 132 135 139.9 137 138 141 146.2 142 143 146 151.5 147 149 152 156.8 154 155 158 163.4 MBh 18.3 18.5 19.0 19.8 18.1 18.4 18.9 19.7 17.7 17.9 18.4 19.2 16.9 17.1 17.7 18.4 15.9 16.2 16.7 17.5 15.1 15.3 15.8 16.6 S/T 0.77 0.70 0.57 0.4 0.77 0.70 0.58 0.4 1.00 0.72 0.60 0.5 1.00 0.74 0.62 0.5 1.00 0.76 0.64 0.5 1.00 1.00 0.69 0.6 AT 21 20 16 12 21 19 16 12 22 20 16 13 21 19 16 12 21 19 16 12 22 20 17 13 675 kW 1.13 1.13 1.13 1.1 1.26 1.26 1.25 1.3 1.39 1.39 1.39 1.4 1.54 1.54 1.54 1.5 1.71 1.71 1.71 1.7 1.90 1.90 1.90 1.9 Amps 4.1 4.1 4.1 4.2 4.7 4.7 4.7 4.7 5.3 5.3 5.3 5.4 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 HiPR 240 241 243 246.9 277 278 280 283.7 316 317 318 322.3 357 358 360 363.8 402 403 404 408.6 450 451 452 456.3 Lo PR 126 127 130 135.3 133 134 137 142.5 139 141 144 148.8 145 146 149 154.2 150 151 154 159.5 156 158 161 166.0 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW =Total system power k 00 0 0 Q v 0a 0 E3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 17.6 17.9 18.4 19.2 17.5 17.7 18.2 19.0 17.0 17.3 17.8 18.6 16.2 16.3 17.0 17.8 15.3 15.5 16.1 16.8 14.4 14.7 15.2 16.0 S/T 0.84 0.77 0.65 0.5 1.00 0.78 0.65 0.5 1.00 0.80 0.67 0.5 1.00 0.82 0.69 0.6 1.00 1.00 0.71 0.6 1.00 1.00 0.76 0.6 AT 28 26 22 19 28 26 22 19 28 26 23 19 28 26 22 19 27 26 22 18 29 27 23 20 520 kW 1.12 1.12 1.12 1.1 1.25 1.24 1.24 1.3 1.38 1.38 1.38 1.4 1.53 1.53 1.53 1.5 1.70 1.70 1.70 1.7 1.89 1.89 1.89 1.9 Amps 4.1 4.1 4.1 4.1 4.7 4.6 4.6 4.7 5.3 5.3 5.3 5.3 6.0 6.0 5.9 6.0 6.7 6.7 6.7 6.8 7.6 7.6 7.6 7.6 Hi PR 236 237 239 242.6 273 274 275 279.4 311 312 314 318.0 353 354 355 359.5 398 399 400 404.3 445 446 448 452.1 Lo PR 121 123 126 130.7 128 130 133 138.0 135 136 139 144.3 140 142 145 149.7 145 147 150 154.9 152 153 156 161.5 MBh 18.0 18.2 18.7 19.5 17.8 18.1 18.6 19.4 17.4 17.6 18.1 18.9 16.6 16.8 17.3 18.1 15.6 15.9 16.4 17.2 14.8 15.0 15.5 16.3 S/T 1.00 0.81 0.68 0.6 1.00 0.81 0.69 0.6 1.00 0.83 0.71 0.6 1.00 0.85 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.79 0.7 AT 27 25 21 17 27 25 21 17 27 25 21 18 27 25 21 17 26 24 21 17 27 26 22 18 80 600 kW 1.13 1.13 1.13 1.14 1.25 1.25 1.25 1.26 1.39 1.39 1.39 1.40 1.54 1.54 1.54 1.54 1.70 1.70 1.70 1.71 1.90 1.90 1.90 1.91 Amps 4.1 4.1 4.1 4.1 4.7 4.7 4.7 4.7 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.0 6.8 6.7 6.7 6.8 7.6 7.6 7.6 7.7 Hi PR 238 239 241 245.0 275 276 278 281.8 314 315 316 320.4 355 356 358 361.9 400 401 403 406.7 448 449 450 454.5 Lo PR 124 125 128 133.2 131 132 135 140.4 137 139 142 146.7 143 144 147 152.1 148 149 152 157.3 154 156 159 163.9 MBh 18.4 18.6 19.1 19.9 18.2 18.5 19.0 19.8 17.8 18.0 18.5 19.3 17.0 17.2 17.7 18.5 16.0 16.3 16.8 17.6 15.2 15.4 15.9 16.7 S/T 1.00 0.81 0.69 0.6 1.00 0.82 0.69 0.6 1.00 0.84 0.72 0.6 1.00 1.00 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.80 0.7 AT 26 24 20 17 26 24 20 16 26 24 20 17 26 24 20 16 25 23 20 16 27 25 21 17 675 kW 1.13 1.13 1.13 1.1 1.26 1.26 1.25 1.3 1.39 1.39 1.39 1.4 1.54 1.54 1.54 1.6 1.71 1.71 1.71 1.7 1.91 1.90 1.90 1.9 Amps 4.1 4.1 4.1 4.2 4.7 4.7 4.7 4.7 5.3 5.3 5.3 5.4 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 Hi PR 241 242 243 247.3 277 278 280 284.1 316 317 319 322.7 357 359 360 364.2 402 403 405 409.0 450 451 453 456.8 Lo PR 126 128 131 135.8 133 135 138 143.0 140 141 144 149.4 145 147 150 154.7 150 152 155 160.0 157 158 162 166.6 MBh 17.9 18.2 18.7 19.5 17.8 18.0 18.5 19.3 17.3 17.6 18.1 18.9 16.5 16.8 17.3 18.1 15.6 15.8 16.3 17.1 14.7 15.0 15.5 16.3 S/T 1.00 0.86 0.74 0.6 1.00 0.87 0.74 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.85 0.7 AT 32 30 26 22 31 30 26 22 32 30 26 23 31 30 26 22 31 29 26 22 32 30 27 23 520 kW 1.12 1.12 1.12 1.1 1.25 1.25 1.24 1.3 1.39 1.38 1.38 1.4 1.53 1.53 1.53 1.5 1.70 1.70 1.70 1.7 1.90 1.89 1.89 1.9 Amps 4.1 4.1 4.1 4.1 4.7 4.7 4.6 4.7 5.3 5.3 5.3 5.3 6.0 6.0 6.0 6.0 6.7 6.7 6.7 6.8 7.6 7.6 7.6 7.7 Hi PR 237 238 240 243.7 274 275 276 280.5 312 313 315 319.1 354 355 357 360.6 399 400 401 405.4 446 447 449 453.2 Lo PR 123 124 127 132.5 130 132 135 139.7 137 138 141 146.1 142 143 146 151.4 147 149 152 156.7 154 155 158 163.3 MBh 18.3 18.5 19.0 19.8 18.1 18.3 18.9 19.7 17.7 17.9 18.4 19.2 16.9 17.1 17.6 18.4 15.9 16.2 16.7 17.5 15.1 15.3 15.8 16.6 S/T 1.00 0.90 0.77 0.6 1.00 0.90 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 1.00 0.8 AT 30 28 25 21 30 28 25 21 31 29 25 21 30 28 25 21 30 28 25 21 31 29 26 22 85 600 kW 1.13 1.13 1.13 1.14 1.25 1.25 1.25 1.26 1.39 1.39 1.39 1.40 1.54 1.54 1.54 1.55 1.71 1.71 1.70 1.71 1.90 1.90 1.90 1.91 Amps 4.1 4.1 4.1 4.2 4.7 4.7 4.7 4.7 5.3 5.3 5.3 5.4 6.0 6.0 6.0 6.0 6.8 6.8 6.7 6.8 7.7 7.7 7.6 7.7 Hi PR 239 240 242 246.1 276 277 279 282.9 315 316 317 321.5 356 357 359 363.0 401 402 404 407.8 449 450 451 455.6 Lo PR 125 127 130 134.9 133 134 137 142.2 139 140 143 148.5 144 146 149 153.9 150 151 154 159.1 156 158 161 165.7 MBh 18.7 18.9 19.4 20.2 18.5 18.7 19.3 20.1 18.1 18.3 18.8 19.6 17.3 17.5 18.0 18.8 16.3 16.6 17.1 17.9 15.5 15.7 16.2 17.0 S/T 1.00 0.90 0.78 0.6 1.00 1.00 0.78 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 1.00 0.8 AT 29 27 24 20 29 27 24 20 30 28 24 20 29 27 24 20 29 27 24 20 30 28 25 21 675 kW 1.14 1.14 1.13 1.1 1.26 1.26 1.26 1.3 1.40 1.40 1.39 1.4 1.55 1.55 1.54 1.6 1.71 1.71 1.71 1.7 1.91 1.91 1.90 1.9 Amps 4.2 4.1 4.1 4.2 4.7 4.7 4.7 4.7 5.3 5.3 5.3 5.4 6.0 6.0 6.0 6.1 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 Hi PR 242 243 244 248.4 278 280 281 285.2 317 318 320 323.8 359 360 361 365.3 403 404 406 410.1 451 452 454 457.9 Lo PR 128 129 133 137.6 135 137 140 144.8 142 143 146 151.2 147 148 151 156.5 152 154 157 161.8 159 160 163 168.3 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n z 0 n, O O r_ z G1 a G) k z W z 00 N N 44 N ti n r) n O z y uq 0 0 0- 3 Cu 3 amp' 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW MBh 23.0 23.3 24.0 - 22.8 23.1 23.8 - 22.2 22.5 23.2 - 21.2 21.5 22.2 - 19.9 20.2 20.9 - 18.7 19.1 19.8 - S/T 0.56 0.49 0.36 0.56 0.49 0.37 0.59 0.52 0.39 0.61 0.54 0.41 1.00 0.56 0.43 1.00 0.60 0.48 AT 19 17 14 19 17 14 19 18 14 19 17 14 19 17 14 20 18 15 750 kW 1.49 1.49 1.49 1.65 1.65 1.65 1.83 1.83 1.83 2.03 2.03 2.02 2.25 2.25 2.24 2.50 2.50 2.50 Amps 5.1 5.1 5.1 5.9 5.9 5.9 6.7 6.7 6.7 7.6 7.6 7.6 8.6 8.6 8.6 9.8 9.8 9.8 HiPR 255 256 258 295 296 298 337 339 340 383 384 386 432 433 435 484 485 487 Lo PR 123 125 128 131 132 135 137 139 142 143 144 147 148 150 153 155 157 160 MBh 23.3 23.6 24.3 23.1 23.4 24.1 22.5 22.8 23.5 21.5 21.8 22.5 20.2 20.5 21.2 19.0 19.4 20.1 S/T 0.61 0.54 0.42 0.62 0.55 0.42 0.64 0.57 0.45 1.00 0.59 0.47 1.00 0.61 0.49 1.00 0.66 0.53 AT 18 16 13 18 16 13 18 17 13 18 16 13 18 16 13 19 17 14 70 800 kW 1.50 1.50 1.50 1.66 1.66 1.66 1.84 1.84 1.84 2.04 2.04 2.03 2.25 2.25 2.25 2.51 2.51 2.51 Amps 5.2 5.2 5.2 5.9 5.9 5.9 6.8 6.7 6.7 7.6 7.6 7.6 8.6 8.6 8.6 9.8 9.8 9.8 HiPR 257 258 260 297 299 300 340 341 343 385 386 388 434 435 437 486 487 489 Lo PR 125 127 130 133 134 137 139 141 144 145 146 149 150 152 155 157 158 162 MBh 23.7 24.0 24.7 23.5 23.8 24.5 22.9 23.2 23.9 21.8 22.1 22.8 20.6 20.9 21.6 19.4 19.7 20.4 S/T 0.65 0.58 0.45 0.65 0.58 0.46 0.67 0.60 0.48 1.00 0.62 0.50 1.00 0.64 0.52 1.00 0.69 0.56 AT 17 15 12 17 15 12 17 16 12 17 15 12 17 15 12 18 16 13 900 kW 1.51 1.51 1.50 1.67 1.67 1.66 1.85 1.85 1.84 2.04 2.04 2.04 2.26 2.26 2.26 2.52 2.52 2.51 Amps 5.2 5.2 5.2 6.0 6.0 5.9 6.8 6.8 6.8 7.7 7.7 7.7 8.7 8.7 8.7 9.8 9.8 9.8 HiPR 259 260 262 300 301 302 342 343 345 387 388 390 436 437 439 488 489 491 Lo PR 127 129 132 135 136 139 141 143 146 147 148 151 152 154 157 159 160 164 MBh 23.0 23.3 24.0 25.1 22.8 23.1 23.8 24.9 22.2 22.5 23.2 24.3 21.2 21.5 22.2 23.2 19.9 20.2 20.9 22.0 18.8 19.1 19.8 20.8 S/T 0.68 0.61 0.48 0.4 0.68 0.61 0.49 0.4 1.00 0.64 0.51 0.4 1.00 0.65 0.53 0.4 1.00 0.67 0.55 0.4 1.00 1.00 0.60 0.5 AT 23 21 18 15 23 21 18 15 23 22 18 15 23 21 18 15 23 21 18 14 24 22 19 15 750 kW 1.49 1.49 1.49 1.5 1.65 1.65 1.65 1.7 1.83 1.83 1.83 1.8 2.03 2.03 2.02 2.0 2.25 2.24 2.24 2.3 2.50 2.50 2.50 2.5 Amps 5.1 5.1 5.1 5.2 5.9 5.9 5.9 5.9 6.7 6.7 6.7 6.7 7.6 7.6 7.6 7.6 8.6 8.6 8.6 8.6 9.8 9.8 9.8 9.8 HiPR 255 256 258 262.6 296 297 298 302.9 338 339 341 345.0 383 384 386 390.4 432 433 435 439.4 484 485 487 491.6 Lo PR 123 125 128 133.2 131 132 135 140.6 137 139 142 147.2 143 144 148 152.8 148 150 153 158.2 155 157 160 165.0 MBh 23.3 23.6 24.3 25.4 23.1 23.4 24.1 25.2 22.5 22.8 23.5 24.6 21.5 21.8 22.5 23.5 20.2 20.5 21.2 22.3 19.1 19.4 20.1 21.1 S/T 0.73 0.66 0.54 0.4 0.74 0.67 0.54 0.4 1.00 0.69 0.57 0.4 1.00 0.71 0.58 0.5 1.00 0.73 0.60 0.5 1.00 1.00 0.65 0.5 AT 22 20 17 14 22 20 17 13 22 20 17 14 22 20 17 13 22 20 17 13 23 21 18 14 75 800 kW 1.50 1.50 1.49 1.51 1.66 1.66 1.66 1.67 1.84 1.84 1.84 1.85 2.04 2.03 2.03 2.04 2.25 2.25 2.25 2.26 2.51 2.51 2.51 2.52 Amps 5.2 5.2 5.2 5.2 5.9 5.9 5.9 6.0 6.7 6.7 6.7 6.8 7.6 7.6 7.6 7.7 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.8 HiPR 257 259 260 264.8 298 299 301 305.0 340 341 343 347.2 385 386 388 392.6 434 435 437 441.6 486 488 489 493.8 Lo PR 125 127 130 135.0 133 134 137 142.5 139 141 144 149.0 145 146 149 154.6 150 152 155 160.0 157 158 162 166.8 MBh 23.7 24.0 24.7 25.7 23.5 23.8 24.5 25.5 22.9 23.2 23.9 24.9 21.8 22.2 22.8 23.9 20.6 20.9 21.6 22.6 19.4 19.7 20.4 21.5 S/T 0.76 0.69 0.57 0.4 1.00 0.70 0.57 0.4 1.00 0.72 0.60 0.5 1.00 0.74 0.62 0.5 1.00 0.76 0.64 0.5 1.00 1.00 0.68 0.6 AT 21 19 16 13 21 19 16 13 21 20 16 13 21 19 16 13 21 19 16 12 22 20 17 13 900 kW 1.51 1.50 1.50 1.5 1.67 1.67 1.66 1.7 1.85 1.85 1.84 1.9 2.04 2.04 2.04 2.1 2.26 2.26 2.26 2.3 2.52 2.52 2.51 2.5 Amps 5.2 5.2 5.2 5.3 6.0 5.9 5.9 6.0 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 8.7 8.7 8.7 8.7 9.8 9.8 9.8 9.9 HiPR 260 261 262 266.9 300 301 303 307.1 342 343 345 349.3 387 388 390 394.7 436 437 439 443.7 489 490 491 495.9 Lo PR 127 129 132 137.0 135 136 139 144.5 141 143 146 151.0 147 148 151 156.6 152 154 157 162.0 159 160 164 168.9 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power x n z T n O O z C) n G) X z W z N I� Nj Iv Nj 00 0 0 Q v pa 0 0 E3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 23.1 23.5 24.1 25.2 22.9 23.2 23.9 25.0 22.3 22.6 23.3 24.4 21.3 21.6 22.3 23.3 20.0 20.3 21.0 22.1 18.9 19.2 19.9 20.9 S/T 1.00 0.72 0.60 0.5 1.00 0.73 0.60 0.5 1.00 0.75 0.63 0.5 1.00 0.77 0.64 0.5 1.00 1.00 0.67 0.5 1.00 1.00 0.71 0.6 AT 27 25 22 19 27 25 22 18 27 25 22 19 27 25 22 18 27 25 22 18 28 26 23 19 750 kW 1.49 1.49 1.49 1.5 1.65 1.65 1.65 1.7 1.83 1.83 1.83 1.8 2.03 2.03 2.02 2.0 2.25 2.25 2.24 2.3 2.50 2.50 2.50 2.5 Amps 5.1 5.1 5.1 5.2 5.9 5.9 5.9 5.9 6.7 6.7 6.7 6.7 7.6 7.6 7.6 7.6 8.6 8.6 8.6 8.6 9.8 9.8 9.8 9.8 Hi PR 256 257 259 263.1 296 297 299 303.3 338 339 341 345.5 384 385 386 390.9 433 434 435 439.9 485 486 488 492.1 Lo PR 124 125 128 133.7 131 133 136 141.2 138 139 143 147.8 143 14S 148 153.3 149 150 154 158.8 156 157 160 165.6 MBh 23.4 23.8 24.4 25.5 23.2 23.5 24.2 25.3 22.6 22.9 23.6 24.7 21.6 21.9 22.6 23.6 20.3 20.7 21.3 22.4 19.2 19.5 20.2 21.2 S/T 1.00 0.78 0.65 0.5 1.00 0.78 0.66 0.5 1.00 0.81 0.68 0.6 1.00 1.00 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.77 0.6 AT 26 24 21 17 26 24 21 17 26 24 21 18 26 24 21 17 26 24 21 17 27 25 22 18 80 800 kW 1.50 1.50 1.50 1.51 1.66 1.66 1.66 1.67 1.84 1.84 1.84 1.85 2.04 2.04 2.03 2.04 2.25 2.25 2.25 2.26 2.51 2.51 2.51 2.52 Amps 5.2 5.2 5.2 5.2 5.9 5.9 5.9 6.0 6.7 6.7 6.7 6.8 7.6 7.6 7.6 7.7 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.9 Hi PR 258 259 261 265.3 298 299 301 305.5 340 341 343 347.7 386 387 389 393.1 435 436 438 442.0 487 488 490 494.3 Lo PR 126 127 130 135.5 133 135 138 143.0 140 141 144 149.6 145 147 150 155.1 151 152 155 160.6 157 159 162 167.4 MBh 23.8 24.1 24.8 25.9 23.6 23.9 24.6 25.6 23.0 23.3 24.0 25.0 22.0 22.3 23.0 24.0 20.7 21.0 21.7 22.7 19.5 19.9 20.5 21.6 S/T 1.00 0.81 0.68 0.6 1.00 0.82 0.69 0.6 1.00 0.84 0.71 0.6 1.00 1.00 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.80 0.7 AT 25 23 20 17 25 23 20 16 25 24 20 17 25 23 20 16 25 23 20 16 26 24 21 17 900 kW 1.51 1.50 1.50 1.5 1.67 1.67 1.66 1.7 1.85 1.85 1.84 1.9 2.04 2.04 2.04 2.1 2.26 2.26 2.26 2.3 2.52 2.52 2.51 2.5 Amps 5.2 5.2 5.2 5.3 6.0 6.0 5.9 6.0 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 8.7 8.7 8.7 8.7 9.8 9.8 9.8 9.9 Hi PR 260 261 263 267.4 300 301 303 307.6 342 344 345 349.8 388 389 391 395.2 437 438 440 444.1 489 490 492 496.4 Lo PR 1 128 129 132 137.5 135 137 140 145.0 142 143 146 151.6 147 149 152 157.1 153 154 157 162.6 159 161 164 169.4 MBh 23.5 23.8 24.5 25.6 23.3 23.6 24.3 25.4 22.7 23.0 23.7 24.8 21.7 22.0 22.7 23.7 20.4 20.7 21.4 22.5 19.3 19.6 20.3 21.3 S/T 1.00 0.82 0.69 0.6 1.00 0.82 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 1.00 0.7 AT 31 29 25 22 30 29 25 22 31 29 26 22 30 29 25 22 30 28 25 22 31 30 26 23 750 kW 1.49 1.49 1.49 1.5 1.66 1.65 1.65 1.7 1.84 1.83 1.83 1.8 2.03 2.03 2.03 2.0 2.25 2.25 2.25 2.3 2.51 2.50 2.50 2.5 Amps 5.2 5.2 5.1 5.2 5.9 5.9 5.9 5.9 6.7 6.7 6.7 6.8 7.6 7.6 7.6 7.7 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.8 Hi PR 257 258 260 264.3 297 298 300 304.5 339 340 342 346.7 385 386 388 392.1 434 435 437 441.1 486 487 489 493.3 Lo PR 126 127 130 135.5 133 135 138 143.0 140 141 144 149.6 145 147 150 155.2 151 152 155 160.6 158 159 162 167.4 MBh 23.8 24.1 24.8 25.9 23.6 23.9 24.6 25.7 23.0 23.3 24.0 25.1 22.0 22.3 23.0 24.0 20.7 21.0 21.7 22.8 19.6 19.9 20.6 21.6 S/T 1.00 0.87 0.75 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.79 0.7 1.00 1.00 0.81 0.7 1.00 1.00 1.00 0.7 AT 29 28 24 21 29 28 24 21 30 28 25 21 29 28 24 21 29 27 24 21 30 29 25 22 85 800 kW 1.50 1.50 1.50 1.51 1.66 1.66 1.66 1.67 1.84 1.84 1.84 1.85 2.04 2.04 2.04 2.05 2.26 2.26 2.25 2.27 2.51 2.51 2.51 2.52 Amps 5.2 5.2 5.2 5.2 5.9 5.9 5.9 6.0 6.8 6.8 6.7 6.8 7.7 7.7 7.6 7.7 8.7 8.7 8.6 8.7 9.8 9.8 9.8 9.9 Hi PR 259 260 262 266.5 299 300 302 306.7 342 343 344 348.9 387 388 390 394.3 436 437 439 443.2 488 489 491 495.5 Lo PR 127 129 132 137.4 135 136 140 144.9 142 143 146 151.4 147 149 152 157.0 153 154 157 162.4 159 161 164 169.2 MBh 24.2 24.5 25.2 26.2 24.0 24.3 25.0 26.0 23.4 23.7 24.4 25.4 22.3 22.7 23.4 24.4 21.1 21.4 22.1 23.1 19.9 20.2 20.9 22.0 S/T 1.00 0.90 0.78 0.6 1.00 1.00 0.78 0.7 1.00 1.00 0.81 0.7 1.00 1.00 0.82 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8 AT 29 27 23 20 29 27 23 20 29 27 24 20 29 27 23 20 28 26 23 20 29 28 24 21 900 kW 1.51 1.51 1.51 1.5 1.67 1.67 1.67 1.7 1.85 1.85 1.85 1.9 2.05 2.05 2.04 2.1 2.26 2.26 2.26 2.3 2.52 2.52 2.52 2.5 Amps 5.2 5.2 5.2 5.3 6.0 6.0 6.0 6.0 6.8 6.8 6.8 6.8 7.7 7.7 7.7 7.7 8.7 8.7 8.7 8.7 9.9 9.9 9.8 9.9 Hi PR 261 262 264 268.6 301 303 304 308.8 344 345 347 351.0 389 390 392 396.4 438 439 441 445.3 490 491 493 497.6 Lo PR 129 131 134 139.4 137 138 142 146.9 144 145 148 153.4 149 151 154 159.0 155 156 159 164.4 161 163 166 171.2 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k z 0 m n O O z G) z Cu z N .p I-" N 44 Iv Iv r) n O z y uq 0 0 0- 3 Cu 3 amp' 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 113113 MBh 28.7 29.1 29.9 - 28.4 28.8 29.7 - 27.7 28.1 28.9 - 26.4 26.8 27.6 - 24.8 25.2 26.0 - 23.3 23.7 24.6 - S/T 0.54 0.46 0.33 0.54 0.47 0.33 0.57 0.49 0.36 0.58 0.51 0.38 1.00 0.53 0.40 1.00 0.58 0.45 AT 20 19 15 20 18 15 21 19 15 20 18 15 20 18 15 21 19 16 875 kW 1.89 1.88 1.88 2.10 2.09 2.09 2.33 2.33 2.33 2.59 2.59 2.58 2.87 2.87 2.87 3.21 3.20 3.20 Amps 6.6 6.6 6.6 7.6 7.6 7.5 8.6 8.6 8.6 9.8 9.8 9.8 11.1 11.1 11.1 12.6 12.6 12.6 HiPR 253 255 256 294 295 297 336 337 339 381 382 384 430 431 433 482 484 485 Lo PR 122 124 127 130 131 134 136 138 141 142 143 146 147 149 152 154 155 159 MBh 29.0 29.4 30.2 28.7 29.1 30.0 28.0 28.4 29.2 26.7 27.1 27.9 25.1 25.5 26.4 23.6 24.0 24.9 S/T 0.61 0.53 0.40 0.61 0.54 0.41 0.64 0.56 0.43 1.00 0.58 0.45 1.00 0.60 0.47 1.00 0.66 0.52 AT 19 17 14 19 17 14 19 18 14 19 17 14 19 17 14 20 18 15 70 1000 kW 1.90 1.90 1.89 2.11 2.11 2.10 2.34 2.34 2.34 2.60 2.60 2.59 2.88 2.88 2.88 3.22 3.22 3.21 Amps 6.7 6.7 6.6 7.6 7.6 7.6 8.7 8.7 8.7 9.9 9.9 9.8 11.2 11.2 11.1 12.7 12.7 12.7 HiPR 256 257 258 296 297 299 338 339 341 383 385 386 432 433 435 485 486 487 Lo PR 124 125 128 131 133 136 138 139 142 143 145 148 149 150 153 156 157 160 MBh 29.3 29.7 30.5 29.0 29.4 30.3 28.3 28.7 29.5 27.0 27.4 28.2 25.4 25.8 26.6 23.9 24.3 25.2 S/T 0.65 0.58 0.44 0.66 0.58 0.45 0.68 0.61 0.47 1.00 0.63 0.49 1.00 0.65 0.51 1.00 0.70 0.56 AT 18 17 13 18 17 13 19 17 13 18 16 13 18 16 13 19 17 14 1105 kW 1.91 1.90 1.90 2.12 2.11 2.11 2.35 2.35 2.35 2.61 2.60 2.60 2.89 2.89 2.89 3.23 3.22 3.22 Amps 6.7 6.7 6.7 7.7 7.7 7.6 8.7 8.7 8.7 9.9 9.9 9.9 11.2 11.2 11.2 12.7 12.7 12.7 HiPR 257 258 260 297 299 300 340 341 343 385 386 388 434 435 437 486 487 489 Lo PR 125 127 130 133 134 137 139 141 144 145 146 149 150 152 155 157 158 162 MBh 28.7 29.1 30.0 31.3 28.4 28.8 29.7 31.0 27.7 28.1 28.9 30.3 26.4 26.8 27.7 29.0 24.8 25.2 26.1 27.4 23.3 23.8 24.6 25.9 S/T 0.66 0.59 0.45 0.3 0.67 0.59 0.46 0.3 1.00 0.62 0.49 0.3 1.00 0.64 0.50 0.4 1.00 0.66 0.53 0.4 1.00 1.00 0.58 0.4 AT 24 22 19 16 24 22 19 16 24 23 19 16 24 22 19 16 24 22 19 15 25 23 20 16 875 kW 1.88 1.88 1.88 1.9 2.10 2.09 2.09 2.1 2.33 2.33 2.33 2.3 2.59 2.58 2.58 2.6 2.87 2.87 2.86 2.9 3.20 3.20 3.20 3.2 Amps 6.6 6.6 6.6 6.7 7.6 7.6 7.5 7.6 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.9 11.1 11.1 11.1 11.2 12.6 12.6 12.6 12.7 HiPR 254 255 257 261.1 294 295 297 301.3 336 337 339 343.5 382 383 384 388.9 430 432 433 437.8 483 484 486 490.1 Lo PR 122 124 127 132.0 130 131 134 139.5 136 138 141 146.1 142 143 146 151.6 147 149 152 157.1 154 155 159 163.9 MBh 29.0 29.4 30.3 31.6 28.7 29.1 30.0 31.3 28.0 28.4 29.3 30.6 26.7 27.1 28.0 29.3 25.1 25.5 26.4 27.7 23.6 24.1 24.9 26.2 S/T 0.73 0.66 0.53 0.4 0.74 0.67 0.53 0.4 1.00 0.69 0.56 0.4 1.00 0.71 0.58 0.4 1.00 0.73 0.60 0.5 1.00 1.00 0.65 0.5 AT 23 21 18 14 23 21 18 14 23 22 18 15 23 21 18 14 23 21 18 14 24 22 19 15 75 1000 kW 1.90 1.89 1.89 1.91 2.11 2.10 2.10 2.12 2.34 2.34 2.34 2.35 2.60 2.60 2.59 2.61 2.88 2.88 2.88 2.89 3.22 3.21 3.21 3.23 Amps 6.7 6.6 6.6 6.7 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.7 9.9 9.9 9.8 9.9 11.2 11.2 11.1 11.2 12.7 12.7 12.7 12.7 HiPR 256 257 259 263.2 296 297 299 303.4 338 339 341 345.6 384 385 387 391.0 433 434 435 439.9 485 486 488 492.2 Lo PR 124 125 128 133.6 131 133 136 141.1 138 139 142 147.6 143 145 148 153.2 149 150 153 158.6 156 157 160 165.5 MBh 29.3 29.7 30.6 31.9 29.0 29.4 30.3 31.6 28.3 28.7 29.5 30.9 27.0 27.4 28.3 29.6 25.4 25.8 26.7 28.0 23.9 24.4 25.2 26.5 S/T 0.78 0.70 0.57 0.4 0.78 0.71 0.58 0.4 1.00 0.73 0.60 0.5 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 1.00 0.69 0.6 AT 22 21 17 14 22 20 17 14 23 21 17 14 22 20 17 14 22 20 17 13 23 21 18 14 1105 kW 1.90 1.90 1.90 1.9 2.11 2.11 2.11 2.1 2.35 2.35 2.34 2.4 2.61 2.60 2.60 2.6 2.89 2.89 2.88 2.9 3.22 3.22 3.22 3.2 Amps 6.7 6.7 6.7 6.7 7.7 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 9.9 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 HiPR 257 259 260 264.8 298 299 301 305.0 340 341 343 347.2 385 386 388 392.6 434 435 437 441.6 486 488 489 493.8 Lo PR 125 127 130 135.0 133 134 137 142.5 139 141 144 149.0 145 146 149 154.6 150 152 155 160.0 157 158 162 166.8 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k 00 0 0 Q v oa 0 E3 OUTDOOR AMBIENT TEMPERATURE 65°F 752F 85°F I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 28.8 29.2 30.1 31.4 28.6 29.0 29.9 31.2 27.8 28.2 29.1 30.4 26.5 26.9 27.8 29.1 24.9 25.4 26.2 27.5 23.5 23.9 24.8 26.1 S/T 1.00 0.71 0.58 0.4 1.00 0.72 0.58 0.4 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 1.00 0.65 0.5 1.00 1.00 0.70 0.6 AT 28 26 23 20 28 26 23 20 28 27 23 20 28 26 23 20 28 26 23 19 29 27 24 20 875 kW 1.89 1.88 1.88 1.9 2.10 2.09 2.09 2.1 2.33 2.33 2.33 2.3 2.59 2.58 2.58 2.6 2.87 2.87 2.87 2.9 3.21 3.20 3.20 3.2 Amps 6.6 6.6 6.6 6.7 7.6 7.6 7.5 7.6 8.6 8.6 8.6 8.7 9.8 9.8 9.8 9.9 11.1 11.1 11.1 11.2 12.6 12.6 12.6 12.7 Hi PR 254 255 257 261.5 294 296 297 301.8 337 338 339 343.9 382 383 385 389.3 431 432 434 438.3 483 484 486 490.5 Lo PR 123 124 127 132.5 130 132 135 140.0 137 138 141 146.6 142 144 147 152.2 148 149 152 157.6 155 156 159 164.4 MBh 29.1 29.6 30.4 31.7 28.9 29.3 30.2 31.5 28.1 28.5 29.4 30.7 26.8 27.2 28.1 29.4 25.2 25.7 26.5 27.8 23.8 24.2 25.1 26.4 S/T 1.00 0.78 0.65 0.5 1.00 0.79 0.66 0.5 1.00 0.81 0.68 0.5 1.00 1.00 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.77 0.6 AT 27 25 22 18 27 25 22 18 27 26 22 19 27 25 22 18 27 25 22 18 28 26 23 19 80 1000 kW 1.90 1.90 1.89 1.91 2.11 2.11 2.10 2.12 2.34 2.34 2.34 2.35 2.60 2.60 2.59 2.61 2.88 2.88 2.88 2.89 3.22 3.22 3.21 3.23 Amps 6.7 6.7 6.6 6.7 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.8 9.9 11.2 11.2 11.1 11.2 12.7 12.7 12.7 12.7 Hi PR 256 257 259 263.6 297 298 299 303.9 339 340 342 346.0 384 385 387 391.4 433 434 436 440.4 485 486 488 492.6 Lo PR 124 126 129 134.1 132 133 136 141.6 138 140 143 148.2 144 145 148 153.7 149 151 154 159.2 156 158 161 166.0 MBh 29.4 29.8 30.7 32.0 29.2 29.6 30.5 31.8 28.4 28.8 29.7 31.0 27.1 27.5 28.4 29.7 25.5 26.0 26.8 28.1 24.1 24.5 25.4 26.7 S/T 1.00 0.82 0.69 0.6 1.00 0.83 0.70 0.6 1.00 0.85 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.81 0.7 AT 26 25 21 18 26 24 21 18 27 25 21 18 26 24 21 18 26 24 21 17 27 25 22 18 1105 kW 1.90 1.90 1.90 1.9 2.12 2.11 2.11 2.1 2.35 2.35 2.35 2.4 2.61 2.60 2.60 2.6 2.89 2.89 2.89 2.9 3.22 3.22 3.22 3.2 Amps 6.7 6.7 6.7 6.7 7.7 7.7 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.2 11.2 11.2 11.3 12.7 12.7 12.7 12.8 Hi PR 258 259 261 265.3 298 299 301 305.5 340 341 343 347.7 386 387 389 393.1 435 436 438 442.0 487 488 490 494.3 Lo PR 1 126 127 130 135.5 133 135 138 143.0 140 141 144 149.6 145 147 150 155.1 151 152 155 160.6 157 159 162 167.4 MBh 29.3 29.7 30.6 31.9 29.1 29.5 30.3 31.7 28.3 28.7 29.6 30.9 27.0 27.4 28.3 29.6 25.4 25.8 26.7 28.0 24.0 24.4 25.3 26.6 S/T 1.00 0.81 0.68 0.5 1.00 0.81 0.68 0.5 1.00 1.00 0.71 0.6 1.00 1.00 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 1.00 0.7 AT 32 30 27 23 32 30 27 23 32 30 27 23 32 30 27 23 31 30 26 23 33 31 27 24 875 kW 1.89 1.89 1.88 1.9 2.10 2.10 2.09 2.1 2.34 2.33 2.33 2.3 2.59 2.59 2.59 2.6 2.88 2.87 2.87 2.9 3.21 3.21 3.20 3.2 Amps 6.6 6.6 6.6 6.7 7.6 7.6 7.6 7.6 8.7 8.7 8.6 8.7 9.8 9.8 9.8 9.9 11.1 11.1 11.1 11.2 12.7 12.7 12.6 12.7 Hi PR 255 256 258 262.7 296 297 299 303.0 338 339 341 345.1 383 384 386 390.5 432 433 435 439.5 484 485 487 491.7 Lo PR 124 126 129 134.4 132 134 137 141.9 139 140 143 148.5 144 146 149 154.0 150 151 154 159.5 156 158 161 166.3 MBh 29.6 30.0 30.9 32.2 29.4 29.8 30.6 32.0 28.6 29.0 29.9 31.2 27.3 27.7 28.6 29.9 25.7 26.1 27.0 28.3 24.3 24.7 25.6 26.9 S/T 1.00 0.88 0.75 0.6 1.00 0.89 0.75 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 1.00 0.7 AT 31 29 25 22 31 29 25 22 31 29 26 22 31 29 25 22 30 29 25 22 31 30 26 23 85 1000 kW 1.90 1.90 1.90 1.91 2.11 2.11 2.11 2.12 2.35 2.35 2.34 2.36 2.60 2.60 2.60 2.61 2.89 2.89 2.88 2.90 3.22 3.22 3.22 3.23 Amps 6.7 6.7 6.7 6.7 7.6 7.6 7.6 7.7 8.7 8.7 8.7 8.8 9.9 9.9 9.9 9.9 11.2 11.2 11.2 11.2 12.7 12.7 12.7 12.8 Hi PR 257 259 260 264.8 298 299 301 305.1 340 341 343 347.2 385 386 388 392.6 434 435 437 441.6 486 488 489 493.8 Lo PR 126 128 131 136.0 134 135 138 143.5 140 142 145 150.0 146 147 150 155.6 151 153 156 161.0 158 159 163 167.8 MBh 29.9 30.3 31.2 32.5 29.7 30.1 30.9 32.3 28.9 29.3 30.2 31.5 27.6 28.0 28.9 30.2 26.0 26.4 27.3 28.6 24.6 25.0 25.9 27.2 S/T 1.00 0.92 0.79 0.7 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 1.00 0.8 AT 30 28 25 21 30 28 25 21 30 28 25 21 30 28 25 21 30 28 24 21 31 29 25 22 1105 kW 1.91 1.91 1.90 1.9 2.12 2.12 2.11 2.1 2.36 2.35 2.35 2.4 2.61 2.61 2.60 2.6 2.89 2.89 2.89 2.9 3.23 3.23 3.22 3.2 Amps 6.7 6.7 6.7 6.8 7.7 7.7 7.7 7.7 8.8 8.7 8.7 8.8 9.9 9.9 9.9 10.0 11.2 11.2 11.2 11.3 12.8 12.7 12.7 12.8 Hi PR 259 260 262 266.5 299 300 302 306.7 342 343 344 348.9 387 388 390 394.3 436 437 439 443.2 488 489 491 495.5 Lo PR 127 129 132 137.4 135 136 140 144.9 142 143 146 151.4 147 149 152 157.0 153 154 157 162.4 159 161 164 169.2 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n C) k z ua z w O N O uq 0 0 0- 3 Cu 3 amp' 0 0 3 OUTDOOR AMBIENT TEMPERATURE 65 75 85 F 95 105 115 ENTERING INDOOR WET BULB TEMPERATURE D: AIRFLOW MBh 34.6 35.1 36.2 - 34.3 34.8 35.9 - 33.4 33.9 34.9 - 31.9 32.3 33.4 - 29.9 30.4 31.5 - 28.2 28.7 29.7 - S/T 0.58 0.50 0.36 0.58 0.51 0.37 0.61 0.53 0.40 0.63 0.55 0.42 1.00 0.57 0.44 1.00 0.63 0.49 AT 21 19 16 21 19 16 21 19 16 21 19 16 21 19 15 22 20 17 1050 kW 2.21 2.21 2.21 2.47 2.47 2.46 2.75 2.75 2.75 3.06 3.06 3.06 3.41 3.41 3.40 3.82 3.81 3.81 Amps 7.9 7.9 7.8 9.0 9.0 9.0 10.3 10.3 10.3 11.8 11.8 11.7 13.3 13.3 13.3 15.2 15.2 15.2 HiPR 256 257 259 296 297 299 339 340 341 384 385 387 433 435 436 486 487 489 Lo PR 121 123 126 129 130 133 135 137 140 141 142 145 146 148 151 153 155 158 MBh 35.3 35.7 36.8 34.9 35.4 36.5 34.0 34.5 35.6 32.5 33.0 34.0 30.6 31.0 32.1 28.8 29.3 30.3 S/T 0.67 0.59 0.46 0.67 0.60 0.46 0.70 0.62 0.49 1.00 0.64 0.51 1.00 0.67 0.53 1.00 0.72 0.58 AT 19 18 14 19 17 14 20 18 14 19 17 14 19 17 14 20 18 15 70 1270 kW 2.23 2.23 2.23 2.49 2.49 2.48 2.77 2.77 2.77 3.08 3.08 3.08 3.43 3.43 3.42 3.83 3.83 3.83 Amps 8.0 7.9 7.9 9.1 9.1 9.1 10.4 10.4 10.4 11.9 11.8 11.8 13.4 13.4 13.4 15.3 15.3 15.3 HiPR 259 260 262 299 300 302 342 343 345 387 388 390 437 438 439 489 490 492 Lo PR 124 125 129 131 133 136 138 139 142 143 145 148 149 150 153 155 157 160 MBh 35.5 36.0 37.0 35.2 35.7 36.7 34.3 34.8 35.8 32.7 33.2 34.3 30.8 31.3 32.4 29.1 29.6 30.6 S/T 0.69 0.61 0.48 0.69 0.62 0.48 0.72 0.64 0.51 1.00 0.66 0.53 1.00 0.69 0.55 1.00 0.74 0.60 AT 19 17 13 19 17 13 19 17 14 19 17 13 19 17 13 20 18 14 1350 kW 2.24 2.24 2.23 2.49 2.49 2.49 2.78 2.78 2.77 3.09 3.09 3.08 3.43 3.43 3.43 3.84 3.84 3.83 Amps 8.0 8.0 8.0 9.2 9.1 9.1 10.5 10.5 10.4 11.9 11.9 11.8 13.5 13.5 13.4 15.3 15.3 15.3 HiPR 260 261 263 300 301 303 343 344 346 388 389 391 438 439 440 490 491 493 Lo PR 125 126 129 132 134 137 139 140 143 144 146 149 150 151 154 156 158 161 MBh 34.7 35.2 36.2 37.8 34.3 34.8 35.9 37.5 33.4 33.9 35.0 36.6 31.9 32.4 33.4 35.0 30.0 30.5 31.5 33.1 28.2 28.7 29.8 31.3 S/T 0.71 0.63 0.49 0.4 0.71 0.64 0.50 0.4 1.00 0.66 0.53 0.4 1.00 0.68 0.54 0.4 1.00 0.70 0.57 0.4 1.00 0.75 0.62 0.5 AT 25 23 20 16 25 23 20 16 26 24 20 16 25 23 20 16 25 23 20 16 26 24 21 17 1050 kW 2.21 2.21 2.20 2.2 2.47 2.47 2.46 2.5 2.75 2.75 2.75 2.8 3.06 3.06 3.06 3.1 3.41 3.41 3.40 3.4 3.81 3.81 3.81 3.8 Amps 7.9 7.9 7.8 7.9 9.0 9.0 9.0 9.1 10.3 10.3 10.3 10.4 11.8 11.7 11.7 11.8 13.3 13.3 13.3 13.4 15.2 15.2 15.2 15.3 HiPR 256 257 259 263.3 296 297 299 303.7 339 340 342 346.2 384 386 387 391.8 434 435 437 441.1 486 487 489 493.6 Lo PR 121 123 126 131.3 129 130 134 138.7 135 137 140 145.2 141 142 146 150.7 146 148 151 156.1 153 155 158 162.9 MBh 35.3 35.8 36.8 38.4 35.0 35.5 36.5 38.1 34.1 34.5 35.6 37.2 32.5 33.0 34.0 35.6 30.6 31.1 32.1 33.7 28.8 29.3 30.4 32.0 S/T 0.80 0.72 0.59 0.4 0.80 0.73 0.59 0.4 1.00 0.75 0.62 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 1.00 0.71 0.6 AT 24 22 18 14 24 22 18 14 24 22 18 15 24 22 18 14 23 21 18 14 24 23 19 15 75 1270 kW 2.23 2.23 2.22 2.24 2.49 2.48 2.48 2.50 2.77 2.77 2.77 2.79 3.08 3.08 3.08 3.09 3.43 3.43 3.42 3.44 3.83 3.83 3.83 3.85 Amps 7.9 7.9 7.9 8.0 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.5 11.8 11.8 11.8 11.9 13.4 13.4 13.4 13.5 15.3 15.3 15.3 15.3 HiPR 259 260 262 266.3 299 301 302 306.8 342 343 345 349.2 388 389 390 394.9 437 438 440 444.1 489 490 492 496.7 Lo PR 124 125 129 133.7 131 133 136 141.2 138 139 142 147.7 143 145 148 153.2 149 150 153 158.6 156 157 160 165.3 MBh 35.5 36.0 37.1 38.7 35.2 35.7 36.8 38.3 34.3 34.8 35.8 37.4 32.8 33.2 34.3 35.9 30.8 31.3 32.4 34.0 29.1 29.6 30.6 32.2 S/T 0.82 0.74 0.61 0.5 0.82 0.75 0.61 0.5 1.00 0.77 0.64 0.5 1.00 0.79 0.66 0.5 1.00 0.81 0.68 0.5 1.00 1.00 0.73 0.6 AT 23 21 18 14 23 21 18 14 23 21 18 14 23 21 18 14 23 21 17 14 24 22 19 15 1350 kW 2.24 2.23 2.23 2.2 2.49 2.49 2.49 2.5 2.78 2.78 2.77 2.8 3.09 3.09 3.08 3.1 3.43 3.43 3.43 3.4 3.84 3.84 3.83 3.9 Amps 8.0 8.0 7.9 8.0 9.1 9.1 9.1 9.2 10.5 10.4 10.4 10.5 11.9 11.9 11.8 11.9 13.5 13.4 13.4 13.5 15.3 15.3 15.3 15.4 HiPR 260 261 263 267.4 300 302 303 307.9 343 344 346 350.3 389 390 391 396.0 438 439 441 445.2 490 491 493 497.7 Lo PR 125 126 130 134.7 132 134 137 142.1 139 140 143 148.6 144 146 149 154.1 150 151 154 159.5 156 158 161 166.3 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (camp.+fan) High and low pressures are measured at the liquid and suction service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions x z m n O O r- z G) z Cu z cu 0) I� n n .p Iv Iv al 0) 00 0 0 Q v oa 0 E3 OUTDOOR AM BIENTTEMPERATURE 659F 752F 859E I 952F 1059F 1152F ENTERING INDOOR WET BULB TEMPERATURE 0: AIRFLOW MBh 34.8 35.3 36.4 38.0 34.5 35.0 36.1 37.6 33.6 34.1 35.1 36.7 32.1 32.5 33.6 35.2 30.1 30.6 31.7 33.3 28.4 28.9 29.9 31.5 S/T 0.83 0.76 0.62 0.5 1.00 0.76 0.63 0.5 1.00 0.79 0.65 0.5 1.00 0.81 0.67 0.5 1.00 1.00 0.69 0.5 1.00 1.00 0.74 0.6 AT 30 28 24 20 29 28 24 20 30 28 24 21 29 28 24 20 29 27 24 20 30 28 25 21 1050 kW 2.21 2.21 2.21 2.2 2.47 2.47 2.46 2.5 2.75 2.75 2.75 2.8 3.06 3.06 3.06 3.1 3.41 3.41 3.40 3.4 3.81 3.81 3.81 3.8 Amps 7.9 7.9 7.8 7.9 9.0 9.0 9.0 9.1 10.3 10.3 10.3 10.4 11.8 11.8 11.7 11.8 13.3 13.3 13.3 13.4 15.2 15.2 15.2 15.3 Hi PR 256 257 259 263.7 297 298 300 304.2 339 340 342 346.6 385 386 388 392.3 434 435 437 441.5 487 488 490 494.1 Lo PR 122 124 127 131.8 129 131 134 139.2 136 137 141 145.7 141 143 146 151.2 147 148 151 156.6 154 155 158 163.4 MBh 35.5 35.9 37.0 38.6 35.1 35.6 36.7 38.3 34.2 34.7 35.8 37.4 32.7 33.2 34.2 35.8 30.8 31.2 32.3 33.9 29.0 29.5 30.5 32.1 S/T 1.00 0.85 0.71 0.6 1.00 0.85 0.72 0.6 1.00 0.88 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.84 0.7 AT 28 26 22 19 28 26 22 19 28 26 23 19 28 26 22 19 28 26 22 18 29 27 23 20 80 1270 kW 2.23 2.23 2.23 2.25 2.49 2.49 2.48 2.50 2.77 2.77 2.77 2.79 3.08 3.08 3.08 3.10 3.43 3.43 3.42 3.44 3.83 3.83 3.83 3.85 Amps 8.0 7.9 7.9 8.0 9.1 9.1 9.1 9.2 10.4 10.4 10.4 10.5 11.8 11.8 11.8 11.9 13.4 13.4 13.4 13.5 15.3 15.3 15.3 15.3 Hi PR 259 261 262 266.8 300 301 303 307.3 342 343 345 349.7 388 389 391 395.4 437 438 440 444.6 490 491 493 497.1 Lo PR 124 126 129 134.3 132 133 137 141.7 138 140 143 148.2 144 145 149 153.7 149 151 154 159.1 156 158 161 165.9 MBh 35.7 36.2 37.2 38.8 35.4 35.9 36.9 38.5 34.5 35.0 36.0 37.6 32.9 33.4 34.5 36.1 31.0 31.5 32.6 34.1 29.3 29.8 30.8 32.4 S/T 1.00 0.87 0.73 0.6 1.00 0.87 0.74 0.6 1.00 0.90 0.76 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.86 0.7 AT 27 25 22 18 27 25 22 18 28 26 22 18 27 25 22 18 27 25 22 18 28 26 23 19 1350 kW 2.24 2.24 2.23 2.3 2.49 2.49 2.49 2.5 2.78 2.78 2.77 2.8 3.09 3.09 3.08 3.1 3.43 3.43 3.43 3.4 3.84 3.84 3.83 3.9 Amps 8.0 8.0 8.0 8.0 9.2 9.1 9.1 9.2 10.5 10.5 10.4 10.5 11.9 11.9 11.8 11.9 13.5 13.4 13.4 13.5 15.3 15.3 15.3 15.4 Hi PR 260 262 263 267.9 301 302 304 308.4 343 344 346 350.8 389 390 392 396.4 438 439 441 445.7 491 492 494 498.2 Lo PR 125 127 130 135.2 133 134 137 142.7 139 141 144 149.2 145 146 149 154.7 150 152 155 160.1 157 159 162 166.8 MBh 35.4 35.9 37.0 38.5 35.1 35.6 36.6 38.2 34.2 34.7 35.7 37.3 32.6 33.1 34.2 35.8 30.7 31.2 32.3 33.9 29.0 29.5 30.5 32.1 S/T 1.00 0.86 0.72 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.7 1.00 1.00 1.00 0.7 AT 33 31 28 24 33 31 28 24 33 32 28 24 33 31 28 24 33 31 27 24 34 32 29 25 1050 kW 2.22 2.22 2.21 2.2 2.47 2.47 2.47 2.5 2.76 2.76 2.75 2.8 3.07 3.07 3.06 3.1 3.41 3.41 3.41 3.4 3.82 3.82 3.81 3.8 Amps 7.9 7.9 7.9 7.9 9.1 9.1 9.0 9.1 10.4 10.4 10.3 10.4 11.8 11.8 11.8 11.8 13.4 13.4 13.3 13.4 15.2 15.2 15.2 15.3 Hi PR 258 259 260 264.9 298 299 301 305.4 340 342 343 347.8 386 387 389 393.5 435 436 438 442.7 488 489 491 495.3 Lo PR 124 125 128 133.6 131 133 136 141.1 138 139 142 147.6 143 145 148 153.1 149 150 153 158.5 155 157 160 165.2 MBh 36.0 36.5 37.6 39.2 35.7 36.2 37.3 38.8 34.8 35.3 36.3 37.9 33.3 33.7 34.8 36.4 31.3 31.8 32.9 34.5 29.6 30.1 31.1 32.7 S/T 1.00 0.95 0.81 0.7 1.00 0.96 0.82 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 32 30 26 22 32 30 26 22 32 30 26 23 32 30 26 22 31 29 26 22 32 31 27 23 85 1270 kW 2.24 2.23 2.23 2.25 2.49 2.49 2.49 2.51 2.78 2.78 2.77 2.79 3.09 3.09 3.08 3.10 3.43 3.43 3.43 3.45 3.84 3.84 3.83 3.85 Amps 8.0 8.0 7.9 8.0 9.1 9.1 9.1 9.2 10.5 10.4 10.4 10.5 11.9 11.9 11.8 11.9 13.5 13.4 13.4 13.5 15.3 15.3 15.3 15.4 Hi PR 261 262 264 268.0 301 302 304 308.5 344 345 346 350.9 389 390 392 396.6 438 440 441 445.8 491 492 494 498.3 Lo PR 126 128 131 136.1 134 135 138 143.5 140 142 145 150.0 146 147 150 155.5 151 153 156 160.9 158 159 162 167.7 MBh 36.3 36.8 37.8 39.4 36.0 36.5 37.5 39.1 35.1 35.6 36.6 38.2 33.5 34.0 35.1 36.6 31.6 32.1 33.1 34.7 29.9 30.4 31.4 33.0 S/T 1.00 0.97 0.83 0.7 1.00 1.00 0.84 0.7 1.00 1.00 0.86 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.91 0.8 1.00 1.00 1.00 0.8 AT 31 29 26 22 31 29 26 22 31 29 26 22 31 29 26 22 31 29 25 22 32 30 26 23 1350 kW 2.24 2.24 2.24 2.3 2.50 2.50 2.49 2.5 2.78 2.78 2.78 2.8 3.09 3.09 3.09 3.1 3.44 3.44 3.43 3.5 3.84 3.84 3.84 3.9 Amps 8.0 8.0 8.0 8.1 9.2 9.2 9.1 9.2 10.5 10.5 10.5 10.5 11.9 11.9 11.9 12.0 13.5 13.5 13.5 13.5 15.3 15.3 15.3 15.4 Hi PR 262 263 265 269.1 302 303 305 309.6 345 346 347 352.0 390 391 393 397.6 439 441 442 446.9 492 493 495 499.4 Lo PR 127 129 132 137.1 135 136 139 144.5 141 143 146 151.0 147 148 151 156.5 152 154 157 161.9 159 160 163 168.7 IDB: Entering Indoor Dry Bulb Temperature High and low pressures are measured at the liquid and suction service valves. Shaded area reflects AHRI conditions kW =Total system power Amps = outdoor unit amps (comp.+fan) Design Subcooling 9±3 °F @ the liquid service valve, ARI 95 test conditions k z m O O 'z G1 n G) k z W z w 0) N O IN .p N N •-0 IM uq 0 0 0- 3 Cu 3 amp' 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 113113 MBh 40.1 40.6 41.8 - 39.7 40.3 41.5 - 38.6 39.2 40.4 - 36.8 37.4 38.6 - 34.6 35.2 36.4 - 32.6 33.2 34.4 - S/T 0.58 0.50 0.37 0.58 0.51 0.37 0.61 0.53 0.40 0.63 0.55 0.42 1.00 0.57 0.44 1.00 0.62 0.49 AT 21 19 16 21 19 15 21 19 16 21 19 15 21 19 15 22 20 16 1225 kW 2.55 2.55 2.54 2.85 2.84 2.84 3.18 3.18 3.17 3.54 3.54 3.53 3.94 3.94 3.94 4.42 4.42 4.41 Amps 9.1 9.0 9.0 10.4 10.4 10.4 12.0 11.9 11.9 13.6 13.6 13.6 15.5 15.4 15.4 17.6 17.6 17.6 HiPR 264 266 267 306 307 309 350 351 353 397 398 400 448 449 451 502 504 505 Lo PR 122 123 126 129 131 134 136 137 140 141 143 146 146 148 151 153 155 158 MBh 40.7 41.3 42.5 40.4 40.9 42.1 39.3 39.9 41.1 37.5 38.1 39.3 35.3 35.9 37.1 33.3 33.8 35.0 S/T 0.66 0.58 0.45 0.66 0.59 0.45 0.69 0.61 0.48 1.00 0.63 0.50 1.00 0.65 0.52 1.00 0.70 0.57 AT 19 18 14 19 17 14 20 18 14 19 17 14 19 17 14 20 18 15 70 1460 kW 2.57 2.57 2.56 2.87 2.86 2.86 3.20 3.20 3.19 3.56 3.56 3.55 3.96 3.96 3.96 4.44 4.44 4.43 Amps 9.2 9.1 9.1 10.5 10.5 10.5 12.0 12.0 12.0 13.7 13.7 13.7 15.5 15.5 15.5 17.7 17.7 17.7 HiPR 267 269 270 309 310 312 353 354 356 400 401 403 451 452 454 505 507 508 Lo PR 124 125 129 131 133 136 138 139 142 143 145 148 149 150 153 156 157 160 MBh 41.1 41.7 42.9 40.7 41.3 42.5 39.7 40.3 41.5 37.9 38.5 39.7 35.7 36.2 37.4 33.7 34.2 35.4 S/T 0.68 0.61 0.47 0.69 0.61 0.48 0.71 0.64 0.50 1.00 0.66 0.52 1.00 0.68 0.54 1.00 0.73 0.59 AT 19 17 13 19 17 13 19 17 14 19 17 13 18 17 13 20 18 14 1575 kW 2.58 2.57 2.57 2.88 2.87 2.87 3.21 3.21 3.20 3.57 3.57 3.56 3.97 3.97 3.97 4.45 4.44 4.44 Amps 9.2 9.2 9.2 10.6 10.5 10.5 12.1 12.1 12.1 13.7 13.7 13.7 15.6 15.6 15.5 17.7 17.7 17.7 HiPR 269 270 272 311 312 314 354 356 357 402 403 405 452 454 455 507 508 510 Lo PR 125 127 130 133 134 137 139 141 144 145 146 149 150 151 155 157 158 161 MBh 40.1 40.6 41.8 43.7 39.7 40.3 41.5 43.3 38.7 39.2 40.4 42.3 36.9 37.4 38.6 40.5 34.7 35.2 36.4 38.3 32.6 33.2 34.4 36.2 S/T 0.70 0.63 0.49 0.4 0.71 0.63 0.50 0.4 1.00 0.66 0.52 0.4 1.00 0.68 0.54 0.4 1.00 0.70 0.57 0.4 1.00 1.00 0.62 0.5 AT 25 23 20 16 25 23 20 16 25 23 20 16 25 23 20 16 25 23 19 16 26 24 21 17 1225 kW 2.55 2.54 2.54 2.6 2.84 2.84 2.84 2.9 3.18 3.18 3.17 3.2 3.54 3.54 3.53 3.6 3.94 3.94 3.93 4.0 4.42 4.41 4.41 4.4 Amps 9.0 9.0 9.0 9.1 10.4 10.4 10.4 10.5 11.9 11.9 11.9 12.0 13.6 13.6 13.6 13.7 15.4 15.4 15.4 15.5 17.6 17.6 17.6 17.7 HiPR 265 266 268 272.3 306 308 310 314.1 350 351 353 358.0 398 399 401 405.1 448 450 451 456.0 503 504 506 510.3 Lo PR 122 123 126 131.5 129 131 134 138.9 136 137 140 145.4 141 143 146 150.9 146 148 151 156.3 153 155 158 163.1 MBh 40.7 41.3 42.5 44.3 40.4 40.9 42.1 44.0 39.3 39.9 41.1 42.9 37.5 38.1 39.3 41.1 35.3 35.9 37.1 38.9 33.3 33.9 35.1 36.9 S/T 0.78 0.71 0.58 0.4 0.79 0.72 0.58 0.4 1.00 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 0.78 0.65 0.5 1.00 1.00 0.70 0.6 AT 24 22 18 14 24 22 18 14 24 22 18 15 24 22 18 14 23 21 18 14 25 23 19 15 75 1460 kW 2.57 2.56 2.56 2.58 2.87 2.86 2.86 2.88 3.20 3.20 3.19 3.21 3.56 3.56 3.55 3.58 3.96 3.96 3.96 3.98 4.44 4.43 4.43 4.45 Amps 9.1 9.1 9.1 9.2 10.5 10.5 10.5 10.6 12.0 12.0 12.0 12.1 13.7 13.7 13.7 13.8 15.5 15.5 15.5 15.6 17.7 17.7 17.7 17.8 HiPR 268 269 271 275.2 309 311 312 317.1 353 354 356 360.9 400 402 403 408.1 451 452 454 459.0 506 507 509 513.3 Lo PR 124 125 129 133.8 131 133 136 141.2 138 139 143 147.7 143 145 148 153.2 149 150 153 158.6 156 157 160 165.4 MBh 41.1 41.7 42.9 44.7 40.8 41.3 42.5 44.4 39.7 40.3 41.5 43.3 37.9 38.5 39.7 41.5 35.7 36.3 37.5 39.3 33.7 34.3 35.5 37.3 S/T 0.81 0.73 0.60 0.5 0.81 0.74 0.61 0.5 1.00 0.76 0.63 0.5 1.00 0.78 0.65 0.5 1.00 0.81 0.67 0.5 1.00 1.00 0.72 0.6 AT 23 21 18 14 23 21 17 14 23 21 18 14 23 21 17 14 23 21 17 14 24 22 18 15 1575 kW 2.57 2.57 2.57 2.6 2.87 2.87 2.87 2.9 3.21 3.20 3.20 3.2 3.57 3.57 3.56 3.6 3.97 3.97 3.96 4.0 4.44 4.44 4.44 4.5 Amps 9.2 9.2 9.1 9.3 10.6 10.5 10.5 10.6 12.1 12.1 12.0 12.1 13.7 13.7 13.7 13.8 15.6 15.6 15.5 15.6 17.7 17.7 17.7 17.8 HiPR 269 270 272 276.6 311 312 314 318.4 355 356 358 362.3 402 403 405 409.5 453 454 456 460.3 507 508 510 514.6 Lo PR 125 127 130 135.0 133 134 137 142.4 139 141 144 148.9 145 146 149 154.4 150 152 155 159.8 157 158 161 166.6 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k 1 00 0 0 Q v oa 0 0 E3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 85"F I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: AIRIFILOW MBh 40.3 40.9 42.1 43.9 39.9 40.5 41.7 43.5 38.9 39.4 40.6 42.5 37.1 37.6 38.8 40.7 34.9 35.4 36.6 38.5 32.8 33.4 34.6 36.4 S/T 0.83 0.75 0.62 0.5 1.00 0.76 0.62 0.5 1.00 0.78 0.65 0.5 1.00 0.80 0.67 0.5 1.00 1.00 0.69 0.5 1.00 1.00 0.74 0.6 AT 29 27 24 20 29 27 24 20 30 28 24 20 29 27 24 20 29 27 24 20 30 28 25 21 1225 kW 2.55 2.54 2.54 2.6 2.85 2.84 2.84 2.9 3.18 3.18 3.17 3.2 3.54 3.54 3.53 3.6 3.94 3.94 3.94 4.0 4.42 4.41 4.41 4.4 Amps 9.1 9.0 9.0 9.1 10.4 10.4 10.4 10.5 12.0 11.9 11.9 12.0 13.6 13.6 13.6 13.7 15.4 15.4 15.4 15.5 17.6 17.6 17.6 17.7 Hi PR 265 266 268 272.8 307 308 310 314.6 351 352 354 358.4 398 399 401 405.6 449 450 452 456.5 503 504 506 510.8 Lo PR 122 124 127 132.0 130 131 134 139.4 136 138 141 146.0 142 143 146 151.5 147 149 152 156.9 154 155 158 163.6 MBh 40.9 41.5 42.7 44.5 40.6 41.2 42.4 44.2 39.5 40.1 41.3 43.1 37.7 38.3 39.5 41.3 35.5 36.1 37.3 39.1 33.5 34.1 35.3 37.1 S/T 1.00 0.83 0.70 0.6 1.00 0.84 0.71 0.6 1.00 0.86 0.73 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.82 0.7 AT 28 26 22 19 28 26 22 19 28 26 23 19 28 26 22 19 28 26 22 18 29 27 23 20 80 1460 kW 2.57 2.57 2.56 2.58 2.87 2.86 2.86 2.88 3.20 3.20 3.19 3.22 3.56 3.56 3.55 3.58 3.96 3.96 3.96 3.98 4.44 4.44 4.43 4.45 Amps 9.2 9.1 9.1 9.2 10.5 10.5 10.5 10.6 12.0 12.0 12.0 12.1 13.7 13.7 13.7 13.8 15.5 15.5 15.5 15.6 17.7 17.7 17.7 17.8 Hi PR 268 269 271 275.7 310 311 313 317.6 354 355 357 361.4 401 402 404 408.6 452 453 455 459.5 506 507 509 513.8 Lo PR 124 126 129 134.3 132 133 137 141.7 138 140 143 148.2 144 145 149 153.7 149 151 154 159.1 156 158 161 165.9 MBh 41.3 41.9 43.1 44.9 41.0 41.5 42.7 44.6 39.9 40.5 41.7 43.5 38.1 38.7 39.9 41.7 35.9 36.5 37.7 39.5 33.9 34.5 35.7 37.5 S/T 1.00 0.86 0.72 0.6 1.00 0.86 0.73 0.6 1.00 0.89 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.85 0.7 AT 27 25 22 18 27 25 22 18 27 26 22 18 27 25 22 18 27 25 21 18 28 26 23 19 1575 kW 2.58 2.57 2.57 2.6 2.88 2.87 2.87 2.9 3.21 3.21 3.20 3.2 3.57 3.57 3.56 3.6 3.97 3.97 3.97 4.0 4.45 4.44 4.44 4.5 Amps 9.2 9.2 9.2 9.3 10.6 10.5 10.5 10.6 12.1 12.1 12.0 12.2 13.7 13.7 13.7 13.8 15.6 15.6 15.5 15.7 17.7 17.7 17.7 17.8 Hi PR 269 271 272 277.1 311 312 314 318.9 355 356 358 362.8 402 403 405 410.0 453 454 456 460.8 507 509 511 515.1 Lo PR 1 126 127 130 135.5 133 135 138 143.0 140 141 144 149.5 145 147 150 155.0 151 152 155 160.4 157 159 162 167.1 MBh 41.0 41.5 42.7 44.6 40.6 41.2 42.4 44.2 39.6 40.1 41.3 43.2 37.7 38.3 39.5 41.3 35.5 36.1 37.3 39.1 33.5 34.1 35.3 37.1 S/T 1.00 0.85 0.72 0.6 1.00 0.86 0.72 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.79 0.6 1.00 1.00 1.00 0.7 AT 33 31 28 24 33 31 28 24 33 31 28 24 33 31 28 24 33 31 27 24 34 32 29 25 1225 kW 2.55 2.55 2.55 2.6 2.85 2.85 2.84 2.9 3.19 3.18 3.18 3.2 3.55 3.54 3.54 3.6 3.95 3.95 3.94 4.0 4.42 4.42 4.42 4.4 Amps 9.1 9.1 9.0 9.2 10.5 10.4 10.4 10.5 12.0 12.0 11.9 12.0 13.6 13.6 13.6 13.7 15.5 15.5 15.4 15.5 17.6 17.6 17.6 17.7 Hi PR 266 268 269 274.0 308 309 311 315.9 352 353 355 359.7 399 400 402 406.9 450 451 453 457.8 504 506 507 512.1 Lo PR 1 124 126 129 133.8 131 133 136 141.3 138 139 143 147.8 143 145 148 153.3 149 150 153 158.7 156 157 160 165.4 MBh 41.6 42.2 43.4 45.2 41.3 41.8 43.0 44.9 40.2 40.8 42.0 43.8 38.4 39.0 40.2 42.0 36.2 36.8 38.0 39.8 34.2 34.8 36.0 37.8 S/T 1.00 0.93 0.80 0.7 1.00 0.94 0.81 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 1.00 0.8 AT 32 30 26 22 32 30 26 22 32 30 26 23 32 30 26 22 31 29 26 22 32 31 27 23 85 1460 kW 2.57 2.57 2.57 2.59 2.87 2.87 2.86 2.89 3.21 3.20 3.20 3.22 3.57 3.56 3.56 3.58 3.97 3.97 3.96 3.99 4.44 4.44 4.44 4.46 Amps 9.2 9.2 9.1 9.2 10.5 10.5 10.5 10.6 12.1 12.1 12.0 12.1 13.7 13.7 13.7 13.8 15.6 15.6 15.5 15.6 17.7 17.7 17.7 17.8 Hi PR 269 270 272 277.0 311 312 314 318.8 355 356 358 362.6 402 403 405 409.8 453 454 456 460.7 507 509 510 515.0 Lo PR 1 126 128 131 136.1 134 135 138 143.6 140 142 145 150.1 146 147 150 155.6 151 153 156 161.0 158 159 163 167.7 MBh 42.0 42.6 43.8 45.6 41.6 42.2 43.4 45.3 40.6 41.2 42.4 44.2 38.8 39.4 40.6 42.4 36.6 37.2 38.4 40.2 34.6 35.1 36.3 38.2 S/T 1.00 0.96 0.82 0.7 1.00 1.00 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.90 0.8 1.00 1.00 1.00 0.8 AT 31 29 26 22 31 29 25 22 31 29 26 22 31 29 25 22 31 29 25 21 32 30 26 23 1575 kW 2.58 2.58 2.57 2.6 2.88 2.88 2.87 2.9 3.21 3.21 3.21 3.2 3.58 3.57 3.57 3.6 3.98 3.98 3.97 4.0 4.45 4.45 4.44 4.5 Amps 9.2 9.2 9.2 9.3 10.6 10.6 10.5 10.7 12.1 12.1 12.1 12.2 13.8 13.8 13.7 13.8 15.6 15.6 15.6 15.7 17.8 17.8 17.7 17.8 Hi PR 271 272 274 278.3 313 314 316 320.2 356 358 359 364.0 404 405 407 411.2 454 456 457 462.1 509 510 512 516.4 Lo PR 128 129 132 137.4 135 136 140 144.8 141 143 146 151.3 147 148 152 156.8 1S2 154 157 162.2 159 161 164 169.0 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n 51, y� uq 0 0 0- 3 Cu 3 amp' 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 113113 MBh 45.7 46.3 47.7 - 45.3 45.9 47.3 - 44.1 44.7 46.1 - 42.0 42.7 44.0 - 39.5 40.2 41.5 - 37.2 37.9 39.2 - S/T 0.60 0.52 0.39 0.61 0.53 0.39 0.63 0.55 0.42 0.65 0.57 0.44 1.00 0.60 0.46 1.00 0.65 0.51 AT 21 19 16 21 19 16 22 20 16 21 19 16 21 19 15 22 20 17 1480 kW 2.97 2.97 2.97 3.32 3.31 3.31 3.70 3.69 3.69 4.11 4.11 4.10 4.57 4.57 4.56 5.11 5.11 5.10 Amps 10.6 10.6 10.6 12.2 12.2 12.1 13.9 13.9 13.9 15.8 15.8 15.8 17.9 17.9 17.9 20.4 20.4 20.3 HiPR 256 257 259 297 298 300 339 340 342 385 386 388 434 435 437 486 488 489 Lo PR 120 122 125 127 129 132 134 135 138 139 141 144 145 146 149 151 153 156 MBh 46.4 47.0 48.4 46.0 46.6 48.0 44.8 45.4 46.8 42.7 43.4 44.7 40.2 40.9 42.2 37.9 38.6 39.9 S/T 0.67 0.60 0.46 0.68 0.60 0.47 0.71 0.63 0.49 0.72 0.65 0.51 1.00 0.67 0.53 1.00 0.72 0.59 AT 20 18 14 20 18 14 20 18 15 20 18 14 20 18 14 21 19 15 70 1640 kW 3.00 2.99 2.99 3.34 3.33 3.33 3.72 3.72 3.71 4.13 4.13 4.12 4.59 4.59 4.58 5.13 5.13 5.12 Amps 10.7 10.7 10.7 12.3 12.3 12.2 14.0 14.0 14.0 15.9 15.9 15.9 18.0 18.0 18.0 20.5 20.5 20.4 HiPR 259 260 262 299 300 302 342 343 345 387 388 390 436 438 439 489 490 492 Lo PR 122 124 127 129 131 134 136 137 140 141 143 146 147 148 151 153 155 158 MBh 46.9 47.6 49.0 46.5 47.2 48.5 45.3 46.0 47.3 43.3 43.9 45.3 40.8 41.4 42.8 38.5 39.1 40.5 S/T 0.70 0.63 0.49 0.71 0.63 0.49 0.73 0.66 0.52 0.75 0.68 0.54 1.00 0.70 0.56 1.00 0.75 0.61 AT 19 17 14 19 17 13 19 17 14 19 17 13 19 17 13 20 18 14 1800 kW 3.01 3.00 3.00 3.35 3.35 3.34 3.73 3.73 3.72 4.14 4.14 4.13 4.60 4.60 4.59 5.14 5.14 5.14 Amps 10.8 10.7 10.7 12.3 12.3 12.3 14.1 14.1 14.0 16.0 15.9 15.9 18.1 18.1 18.0 20.5 20.5 20.5 HiPR 260 261 263 301 302 304 343 344 346 389 390 392 438 439 441 491 492 494 Lo PR 124 125 128 131 132 135 137 139 142 143 144 147 148 150 153 155 156 159 MBh 45.7 46.4 47.7 49.8 45.3 46.0 47.3 49.4 44.1 44.8 46.1 48.2 42.1 42.7 44.1 46.2 39.5 40.2 41.6 43.6 37.2 37.9 39.3 41.3 S/T 0.73 0.65 0.52 0.4 0.74 0.66 0.52 0.4 1.00 0.68 0.55 0.4 1.00 0.70 0.57 0.4 1.00 0.73 0.59 0.4 1.00 0.78 0.64 0.5 AT 26 24 20 16 26 24 20 16 26 24 20 16 26 24 20 16 25 23 20 16 27 25 21 17 1480 kW 2.97 2.97 2.96 3.0 3.31 3.31 3.31 3.3 3.69 3.69 3.69 3.7 4.11 4.10 4.10 4.1 4.57 4.57 4.56 4.6 5.11 5.11 5.10 5.1 Amps 10.6 10.6 10.6 10.7 12.2 12.1 12.1 12.2 13.9 13.9 13.9 14.0 15.8 15.8 15.8 15.9 17.9 17.9 17.9 18.0 20.4 20.4 20.3 20.5 HiPR 256 257 259 263.7 297 298 300 304.2 339 340 342 346.6 385 386 388 392.3 434 435 437 441.5 487 488 490 494.1 Lo PR 120 122 125 129.7 127 129 132 137.1 134 135 138 143.5 139 141 144 148.9 145 146 149 154.2 151 153 156 160.9 MBh 46.4 47.1 48.4 50.5 46.0 46.6 48.0 50.1 44.8 45.5 46.8 48.9 42.7 43.4 44.8 46.9 40.2 40.9 42.2 44.3 37.9 38.6 40.0 42.0 S/T 0.80 0.73 0.59 0.4 0.81 0.73 0.60 0.5 1.00 0.76 0.62 0.5 1.00 0.78 0.64 0.5 1.00 0.80 0.66 0.5 1.00 1.00 0.72 0.6 AT 24 22 19 15 24 22 19 15 24 22 19 15 24 22 19 15 24 22 18 15 25 23 20 16 75 1640 kW 2.99 2.99 2.98 3.01 3.33 3.33 3.33 3.35 3.72 3.71 3.71 3.73 4.13 4.13 4.12 4.15 4.59 4.59 4.58 4.61 5.13 5.13 5.12 5.15 Amps 10.7 10.7 10.7 10.8 12.3 12.2 12.2 12.3 14.0 14.0 14.0 14.1 15.9 15.9 15.9 16.0 18.0 18.0 18.0 18.1 20.5 20.5 20.4 20.6 HiPR 259 260 262 266.3 299 301 302 306.8 342 343 345 349.2 387 389 390 394.9 437 438 440 444.1 489 490 492 496.6 Lo PR 122 124 127 131.8 129 131 134 139.1 136 137 140 145.5 141 143 146 151.0 147 148 151 156.3 153 155 158 162.9 MBh 47.0 47.6 49.0 51.1 46.6 47.2 48.6 50.7 45.4 46.0 47.4 49.5 43.3 43.9 45.3 47.4 40.8 41.4 42.8 44.9 38.5 39.1 40.5 42.6 S/T 0.83 0.76 0.62 0.5 0.84 0.76 0.63 0.5 1.00 0.79 0.65 0.5 1.00 0.81 0.67 0.5 1.00 0.83 0.69 0.5 1.00 1.00 0.74 0.6 AT 23 21 18 14 23 21 18 14 24 22 18 14 23 21 18 14 23 21 17 14 24 22 19 15 1800 kW 3.01 3.00 3.00 3.0 3.35 3.34 3.34 3.4 3.73 3.73 3.72 3.7 4.14 4.14 4.13 4.2 4.60 4.60 4.59 4.6 5.14 5.14 5.13 5.2 Amps 10.7 10.7 10.7 10.8 12.3 12.3 12.3 12.4 14.1 14.0 14.0 14.1 15.9 15.9 15.9 16.0 18.1 18.0 18.0 18.1 20.5 20.5 20.5 20.6 HiPR 261 262 263 268.0 301 302 304 308.4 343 345 346 350.9 389 390 392 396.5 438 439 441 445.7 491 492 494 498.3 Lo PR 124 125 128 133.3 131 132 136 140.6 137 139 142 147.0 143 144 147 152.5 148 150 153 157.8 155 156 159 164.4 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n Z 0 m n O O z G1 n 00 0 0 Q v qa 0 0 E3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E F 952F 1052F 1159F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 46.0 46.6 48.0 50.1 45.5 46.2 47.6 49.6 44.3 45.0 46.4 48.5 42.3 42.9 44.3 46.4 39.8 40.4 41.8 43.9 37.5 38.1 39.5 41.6 S/T 0.86 0.78 0.64 0.5 1.00 0.79 0.65 0.5 1.00 0.81 0.67 0.5 1.00 0.83 0.69 0.5 1.00 1.00 0.72 0.6 1.00 1.00 0.77 0.6 AT 30 28 24 21 30 28 24 21 30 28 25 21 30 28 24 20 30 28 24 20 31 29 25 21 1480 kW 2.97 2.97 2.97 3.0 3.32 3.31 3.31 3.3 3.70 3.69 3.69 3.7 4.11 4.11 4.10 4.1 4.57 4.57 4.56 4.6 5.11 5.11 5.10 5.1 Amps 10.6 10.6 10.6 10.7 12.2 12.2 12.1 12.3 13.9 13.9 13.9 14.0 15.8 15.8 15.8 15.9 17.9 17.9 17.9 18.0 20.4 20.4 20.3 20.5 Hi PR 257 258 260 264.2 297 298 300 304.7 340 341 343 347.1 385 386 388 392.8 435 436 438 442.0 487 488 490 494.5 Lo PR 121 122 125 130.3 128 129 132 137.6 134 136 139 144.0 140 141 144 149.4 145 147 150 154.7 152 153 156 161.4 MBh 46.6 47.3 48.7 50.8 46.2 46.9 48.3 50.3 45.0 45.7 47.1 49.1 43.0 43.6 45.0 47.1 40.5 41.1 42.5 44.6 38.2 38.8 40.2 42.3 S/T 1.00 0.85 0.72 0.6 1.00 0.86 0.72 0.6 1.00 0.89 0.75 0.6 1.00 0.91 0.77 0.6 1.00 1.00 0.79 0.6 1.00 1.00 0.84 0.7 AT 29 27 23 19 28 27 23 19 29 27 23 19 28 27 23 19 28 26 23 19 29 27 24 20 80 1640 kW 3.00 2.99 2.99 3.01 3.34 3.33 3.33 3.35 3.72 3.72 3.71 3.74 4.13 4.13 4.12 4.15 4.59 4.59 4.58 4.61 5.13 5.13 5.12 5.15 Amps 10.7 10.7 10.7 10.8 12.3 12.3 12.2 12.3 14.0 14.0 14.0 14.1 15.9 15.9 15.9 16.0 18.0 18.0 18.0 18.1 20.5 20.5 20.4 20.6 Hi PR 259 261 262 266.8 300 301 303 307.3 342 343 345 349.7 388 389 391 395.3 437 438 440 444.6 490 491 493 497.1 Lo PR 123 124 127 132.3 130 131 135 139.7 136 138 141 146.1 142 143 146 151.5 147 149 152 156.8 154 155 158 163.5 MBh 47.2 47.8 49.2 51.3 46.8 47.4 48.8 50.9 45.6 46.2 47.6 49.7 43.5 44.2 45.6 47.6 41.0 41.7 43.0 45.1 38.7 39.4 40.7 42.8 S/T 1.00 0.88 0.75 0.6 1.00 0.89 0.75 0.6 1.00 0.91 0.78 0.6 1.00 0.93 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.87 0.7 AT 28 26 22 18 28 26 22 18 28 26 22 19 28 26 22 18 27 25 22 18 29 27 23 19 1800 kW 3.01 3.00 3.00 3.0 3.35 3.35 3.34 3.4 3.73 3.73 3.72 3.7 4.14 4.14 4.13 4.2 4.60 4.60 4.59 4.6 5.14 5.14 5.14 5.2 Amps 10.8 10.7 10.7 10.8 12.3 12.3 12.3 12.4 14.1 14.1 14.0 14.1 16.0 15.9 15.9 16.0 18.1 18.1 18.0 18.1 20.5 20.5 20.5 20.6 Hi PR 261 262 264 268.4 302 303 304 308.9 344 345 347 351.3 390 391 393 397.0 439 440 442 446.2 491 492 494 498.8 Lo PR 124 126 129 133.8 131 133 136 141.2 138 139 142 147.6 143 145 148 153.0 149 150 153 158.3 155 157 160 165.0 MBh 46.7 47.4 48.7 50.8 46.3 47.0 48.3 50.4 45.1 45.8 47.1 49.2 43.1 43.7 45.1 47.2 40.5 41.2 42.6 44.7 38.3 38.9 40.3 42.4 S/T 1.00 0.88 0.75 0.6 1.00 0.89 0.75 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.80 0.7 1.00 1.00 0.82 0.7 1.00 1.00 0.87 0.7 AT 34 32 28 24 34 32 28 24 34 32 28 25 34 32 28 24 33 31 28 24 35 33 29 25 1400 kW 2.98 2.98 2.97 3.0 3.32 3.32 3.31 3.3 3.70 3.70 3.69 3.7 4.12 4.11 4.11 4.1 4.58 4.57 4.57 4.6 5.12 5.11 5.11 5.1 Amps 10.6 10.6 10.6 10.7 12.2 12.2 12.2 12.3 13.9 13.9 13.9 14.0 15.8 15.8 15.8 15.9 17.9 17.9 17.9 18.0 20.4 20.4 20.4 20.5 Hi PR 258 259 261 265.4 299 300 301 305.9 341 342 344 348.3 387 388 390 394.0 436 437 439 443.2 488 489 491 495.7 Lo PR 122 124 127 132.1 130 131 134 139.4 136 138 141 145.8 142 143 146 151.2 147 148 151 156.5 154 155 158 163.2 MBh 47.4 48.1 49.4 51.5 47.0 47.7 49.0 51.1 45.8 46.5 47.8 49.9 43.8 44.4 45.8 47.9 41.2 41.9 43.3 45.3 38.9 39.6 41.0 43.1 S/T 1.00 0.96 0.82 0.7 1.00 0.96 0.83 0.7 1.00 1.00 0.85 0.7 1.00 1.00 0.87 0.7 1.00 1.00 0.89 0.7 1.00 1.00 1.00 0.8 AT 32 30 27 23 32 30 27 23 33 31 27 23 32 30 27 23 32 30 26 23 33 31 28 24 85 1640 kW 3.00 3.00 2.99 3.02 3.34 3.34 3.33 3.36 3.72 3.72 3.72 3.74 4.14 4.13 4.13 4.15 4.60 4.59 4.59 4.62 5.14 5.14 5.13 5.16 Amps 10.7 10.7 10.7 10.8 12.3 12.3 12.3 12.4 14.0 14.0 14.0 14.1 15.9 15.9 15.9 16.0 18.0 18.0 18.0 18.1 20.5 20.5 20.5 20.6 Hi PR 261 262 264 268.0 301 302 304 308.5 343 345 346 350.9 389 390 392 396.5 438 440 441 445.8 491 492 494 498.3 Lo PR 124 126 129 134.1 132 133 136 141.5 138 140 143 147.9 144 145 148 153.3 149 150 153 158.6 156 157 160 165.3 MBh 48.0 48.6 50.0 52.1 47.6 48.2 49.6 51.7 46.4 47.0 48.4 50.5 44.3 45.0 46.3 48.4 41.8 42.4 43.8 45.9 39.5 40.1 41.5 43.6 S/T 1.00 0.99 0.85 0.7 1.00 0.99 0.85 0.7 1.00 1.00 0.88 0.7 1.00 1.00 0.90 0.8 1.00 1.00 0.92 0.8 1.00 1.00 1.00 0.8 AT 32 30 26 22 32 30 26 22 32 30 26 22 32 30 26 22 31 29 26 22 32 31 27 23 1800 kW 3.01 3.01 3.00 3.0 3.35 3.35 3.35 3.4 3.74 3.73 3.73 3.8 4.15 4.15 4.14 4.2 4.61 4.61 4.60 4.6 5.15 5.15 5.14 5.2 Amps 10.8 10.8 10.7 10.9 12.4 12.3 12.3 12.4 14.1 14.1 14.1 14.2 16.0 16.0 15.9 16.1 18.1 18.1 18.1 18.2 20.6 20.6 20.5 20.6 Hi PR 262 263 265 269.6 303 304 306 310.1 345 346 348 352.5 391 392 394 398.2 440 441 443 447.4 493 494 495 500.0 Lo PR 126 127 131 135.6 133 135 138 143.0 140 141 144 149.4 145 147 150 154.8 150 152 155 160.1 157 159 162 166.8 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k n z C3 m 0 n O O r- z O n uq 0 0 0- 3 Cu 3 amp' 0 0 3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE 11313 AIRFLOW MBh 55.7 56.4 58.1 - 55.2 55.9 57.6 - 53.7 54.5 56.2 - 51.3 52.0 53.7 - 48.2 49.0 50.7 - 45.5 46.3 47.9 - S/T 0.61 0.54 0.42 0.62 0.55 0.42 0.64 0.57 0.45 1.00 0.59 0.47 1.00 0.61 0.49 1.00 0.66 0.53 AT 22 20 16 22 19 16 22 20 16 22 19 16 21 19 15 23 21 17 1565 kW 3.69 3.68 3.68 4.14 4.14 4.13 4.65 4.64 4.64 5.20 5.19 5.18 5.81 5.80 5.80 6.53 6.52 6.52 Amps 13.9 13.9 13.8 16.0 15.9 15.9 18.3 18.3 18.2 20.8 20.8 20.7 23.6 23.6 23.5 26.9 26.9 26.8 HIM 281 282 284 325 326 328 371 372 374 421 422 424 474 475 477 531 532 534 Lo PR 127 129 132 135 137 140 142 143 147 147 149 152 153 155 158 160 161 165 MBh 57.8 58.6 60.2 57.3 58.1 59.8 55.9 56.7 58.3 53.4 54.2 55.9 50.4 51.2 52.8 47.7 48.4 50.1 S/T 0.66 0.59 0.46 0.66 0.59 0.47 1.00 0.61 0.49 1.00 0.63 0.51 1.00 0.65 0.53 1.00 1.00 0.57 AT 19 17 13 19 17 13 20 18 14 19 17 13 19 17 13 20 18 14 70 2000 kW 3.73 3.72 3.72 4.18 4.18 4.17 4.69 4.68 4.68 5.24 5.23 5.23 5.85 5.85 5.84 6.57 6.56 6.56 Amps 14.1 14.0 14.0 16.1 16.1 16.1 18.5 18.4 18.4 21.0 21.0 20.9 23.8 23.8 23.7 27.1 27.0 27.0 HiPR 286 287 289 330 331 333 376 377 379 426 427 429 479 481 482 536 538 540 Lo PR 132 134 137 140 142 145 147 148 151 152 154 157 158 159 163 165 166 170 MBh 59.5 60.3 61.9 59.0 59.8 61.4 57.6 58.4 60.0 55.1 55.9 57.5 52.1 52.9 54.5 49.4 50.1 51.8 S/T 0.64 0.57 0.44 1.00 0.57 0.45 1.00 0.59 0.47 1.00 0.61 0.49 1.00 0.63 0.51 1.00 1.00 0.55 AT 18 16 12 18 16 12 19 16 12 18 16 12 18 16 12 19 17 13 2250 kW 3.75 3.74 3.74 4.20 4.20 4.19 4.71 4.70 4.70 5.26 5.25 5.25 5.87 5.87 5.86 6.59 6.58 6.58 Amps 14.2 14.1 14.1 16.2 16.2 16.2 18.6 18.5 18.5 21.1 21.0 21.0 23.9 23.8 23.8 27.2 27.1 27.1 HiPR 290 291 293 333 335 337 380 381 383 429 430 432 483 484 486 540 541 543 Lo PR 136 138 141 144 145 148 150 152 155 156 158 161 162 163 166 168 170 173 MBh 55.7 56.5 58.1 60.6 55.2 56.0 57.6 60.1 53.8 54.5 56.2 58.7 51.3 52.1 53.7 56.2 48.3 49.1 50.7 53.2 45.5 46.3 47.9 50.5 S/T 0.73 0.66 0.54 0.4 1.00 0.67 0.54 0.4 1.00 0.69 0.57 0.4 1.00 0.71 0.58 0.5 1.00 0.73 0.60 0.5 1.00 1.00 0.65 0.5 AT 26 24 20 16 26 24 20 16 27 24 21 16 26 24 20 16 26 24 20 16 27 25 21 17 1565 kW 3.68 3.68 3.67 3.7 4.14 4.13 4.13 4.2 4.64 4.64 4.63 4.7 5.19 5.19 5.18 5.2 5.81 5.80 5.79 5.8 6.52 6.52 6.51 6.5 Amps 13.9 13.8 13.8 14.0 15.9 15.9 15.9 16.0 18.3 18.2 18.2 18.4 20.8 20.8 20.7 20.9 23.6 23.6 23.5 23.7 26.9 26.8 26.8 27.0 HiPR 281 282 284 289.3 325 326 328 333.3 371 372 374 379.3 421 422 424 428.9 474 476 478 482.4 531 533 535 539.5 Lo PR 1 127 129 132 137.6 135 137 140 145.2 142 143 147 151.9 147 149 152 157.6 153 155 158 163.1 160 162 165 170.1 MBh 57.9 58.6 60.3 62.8 57.4 58.1 59.8 62.3 55.9 56.7 58.4 60.9 53.5 54.2 55.9 58.4 50.4 51.2 52.9 55.4 47.7 48.5 50.1 52.6 S/T 0.77 0.70 0.58 0.4 1.00 0.71 0.58 0.5 1.00 0.73 0.61 0.5 1.00 0.75 0.63 0.5 1.00 1.00 0.65 0.5 1.00 1.00 0.69 0.6 AT 24 22 18 14 24 22 18 14 24 22 18 14 24 22 18 14 24 22 18 14 25 23 19 15 75 2000 kW 3.72 3.72 3.71 3.75 4.18 4.18 4.17 4.20 4.69 4.68 4.67 4.71 5.23 5.23 5.22 5.26 5.85 5.84 5.83 5.87 6.56 6.56 6.55 6.59 Amps 14.1 14.0 14.0 14.2 16.1 16.1 16.1 16.2 18.4 18.4 18.4 18.6 21.0 20.9 20.9 21.1 23.8 23.7 23.7 23.9 27.0 27.0 27.0 27.2 HIM 286 288 290 294.5 330 332 334 338.4 376 378 380 384.5 426 427 429 434.1 480 481 483 487.6 537 538 540 544.7 Lo PR 132 134 137 142.5 140 142 145 150.2 147 148 151 156.8 152 154 157 162.5 158 160 163 168.1 165 166 170 175.0 MBh 59.5 60.3 62.0 64.5 59.1 59.8 61.5 64.0 57.6 58.4 60.0 62.5 55.2 55.9 57.6 60.1 52.1 52.9 54.6 57.1 49.4 50.2 51.8 54.3 S/T 1.00 0.68 0.56 0.4 1.00 0.69 0.56 0.4 1.00 0.71 0.59 0.5 1.00 1.00 0.61 0.5 1.00 1.00 0.63 0.5 1.00 1.00 0.67 0.5 AT 23 21 17 13 23 21 17 13 23 21 17 13 23 21 17 13 23 21 17 12 24 22 18 14 2250 kW 3.75 3.74 3.73 3.8 4.20 4.20 4.19 4.2 4.71 4.70 4.69 4.7 5.25 5.25 5.24 5.3 5.87 5.86 5.85 5.9 6.58 6.58 6.57 6.6 Amps 14.1 14.1 14.1 14.3 16.2 16.2 16.2 16.3 18.5 18.5 18.5 18.6 21.0 21.0 21.0 21.2 23.9 23.8 23.8 24.0 27.1 27.1 27.1 27.2 HIM 290 291 293 297.8 334 335 337 341.8 380 381 383 387.8 429 431 433 437.4 483 484 486 490.9 540 541 543 548.0 Lo PR 136 138 141 146.1 144 145 148 153.8 150 152 155 160.5 156 158 161 166.1 162 163 166 171.7 169 170 173 178.6 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power x z m 0 n O O r- z G) 00 0 0 ss v pa 0 0 E3 OUTDOOR AMBIENT TEMPERATURE 652F 752F 852E I 952F 1052F 1152F ENTERING INDOOR WET BULB TEMPERATURE D: MBh 56.0 56.8 58.4 60.9 55.5 56.3 57.9 60.4 54.1 54.8 56.5 59.0 51.6 52.4 54.0 56.5 48.6 49.3 51.0 53.5 45.8 46.6 48.2 50.7 S/T 1.00 0.78 0.65 0.5 1.00 0.78 0.66 0.5 1.00 0.81 0.68 0.6 1.00 1.00 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.77 0.6 AT 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 21 31 29 25 20 32 30 26 22 1565 kW 3.69 3.68 3.68 3.7 4.14 4.14 4.13 4.2 4.65 4.64 4.64 4.7 5.20 5.19 5.18 5.2 5.81 5.80 5.80 5.8 6.53 6.52 6.51 6.5 Amps 13.9 13.9 13.8 14.0 16.0 15.9 15.9 16.1 18.3 18.3 18.2 18.4 20.8 20.8 20.7 20.9 23.6 23.6 23.5 23.7 26.9 26.9 26.8 27.0 Hi PR 282 283 285 289.8 326 327 329 333.8 372 373 375 379.8 421 423 425 429.4 475 476 478 482.9 532 533 535 540.0 Lo PR 128 130 133 138.1 136 137 140 145.8 142 144 147 152.5 148 150 153 158.1 154 155 158 163.7 161 162 165 170.6 MBh 58.1 58.9 60.6 63.1 57.7 58.4 60.1 62.6 56.2 57.0 58.6 61.1 53.7 54.5 56.2 58.7 50.7 51.5 53.2 55.7 48.0 48.8 50.4 52.9 S/T 1.00 0.82 0.69 0.6 1.00 0.83 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 0.76 0.6 1.00 1.00 1.00 0.7 AT 29 27 23 19 29 27 23 19 29 27 23 19 29 27 23 19 28 26 22 18 30 28 24 20 80 2000 kW 3.73 3.72 3.72 3.75 4.18 4.18 4.17 4.20 4.69 4.68 4.68 4.71 5.24 5.23 5.22 5.26 5.85 5.84 5.84 5.87 6.57 6.56 6.56 6.59 Amps 14.1 14.0 14.0 14.2 16.1 16.1 16.1 16.2 18.5 18.4 18.4 18.6 21.0 21.0 20.9 21.1 23.8 23.8 23.7 23.9 27.1 27.0 27.0 27.2 Hi PR 287 288 290 295.0 331 332 334 339.0 377 378 380 385.0 427 428 430 434.6 480 481 483 488.1 537 538 540 545.2 Lo PR 133 135 138 143.1 141 142 145 150.7 147 149 152 157.4 153 155 158 163.1 159 160 163 168.6 165 167 170 175.6 MBh 59.8 60.6 62.3 64.8 59.3 60.1 61.8 64.3 57.9 58.7 60.3 62.8 55.4 56.2 57.9 60.4 52.4 53.2 54.8 57.3 49.7 50.4 52.1 54.6 S/T 1.00 0.80 0.67 0.5 1.00 1.00 0.68 0.5 1.00 1.00 0.70 0.6 1.00 1.00 0.72 0.6 1.00 1.00 0.74 0.6 1.00 1.00 1.00 0.7 AT 28 26 22 17 28 26 22 17 28 26 22 18 28 25 22 17 27 25 21 17 29 27 23 18 2250 kW 3.75 3.74 3.74 3.8 4.20 4.20 4.19 4.2 4.71 4.70 4.70 4.7 5.26 5.25 5.24 5.3 5.87 5.87 5.86 5.9 6.59 6.58 6.58 6.6 Amps 14.2 14.1 14.1 14.3 16.2 16.2 16.2 16.3 18.6 18.5 18.5 18.7 21.1 21.0 21.0 21.2 23.9 23.8 23.8 24.0 27.2 27.1 27.1 27.3 Hi PR 290 291 293 298.3 334 335 337 342.3 380 382 383 388.3 430 431 433 437.9 483 485 487 491.4 540 542 544 548.5 Lo PR 137 138 141 146.7 144 146 149 154.3 151 152 156 161.0 157 158 161 166.7 162 164 167 172.2 169 171 174 179.2 MBh 56.9 57.7 59.3 61.8 56.4 57.2 58.8 61.3 55.0 55.8 57.4 59.9 52.5 53.3 54.9 57.4 49.5 50.3 51.9 54.4 46.7 47.5 49.2 51.7 S/T 1.00 0.87 0.75 0.6 1.00 1.00 0.75 0.6 1.00 1.00 0.78 0.6 1.00 1.00 0.79 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.7 AT 35 33 29 25 35 33 29 25 35 33 29 25 35 33 29 25 35 33 29 25 36 34 30 26 1565 kW 3.70 3.69 3.68 3.7 4.15 4.15 4.14 4.2 4.66 4.65 4.64 4.7 5.20 5.20 5.19 5.2 5.82 5.81 5.81 5.8 6.54 6.53 6.52 6.6 Amps 13.9 13.9 13.9 14.0 16.0 16.0 15.9 16.1 18.3 18.3 18.3 18.4 20.8 20.8 20.8 20.9 23.6 23.6 23.6 23.7 26.9 26.9 26.9 27.0 Hi PR 283 284 286 291.1 327 328 330 335.1 373 374 376 381.1 423 424 426 430.7 476 477 479 484.2 533 534 536 541.3 Lo PR 130 131 135 140.0 138 139 142 147.6 144 146 149 154.3 150 151 155 160.0 155 157 160 165.6 162 164 167 172.5 MBh 59.1 59.8 61.5 64.0 58.6 59.4 61.0 63.5 57.1 57.9 59.6 62.1 54.7 55.5 57.1 59.6 51.7 52.4 54.1 56.6 48.9 49.7 51.3 53.8 S/T 1.00 1.00 0.79 0.7 1.00 1.00 0.79 0.7 1.00 1.00 0.82 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.8 AT 33 31 27 23 33 31 27 23 33 31 27 23 33 31 27 23 33 30 27 22 34 32 28 24 85 2000 kW 3.74 3.73 3.72 3.76 4.19 4.19 4.18 4.21 4.70 4.69 4.69 4.72 5.24 5.24 5.23 5.27 5.86 5.85 5.85 5.88 6.58 6.57 6.56 6.60 Amps 14.1 14.1 14.1 14.2 16.2 16.2 16.1 16.3 18.5 18.5 18.4 18.6 21.0 21.0 21.0 21.1 23.8 23.8 23.8 23.9 27.1 27.1 27.0 27.2 Hi PR 288 289 291 296.3 332 333 335 340.3 378 380 381 386.3 428 429 431 435.9 481 483 485 489.4 538 540 542 546.5 Lo PR 1 135 136 140 144.9 142 144 147 152.6 149 151 154 159.3 155 156 160 164.9 160 162 165 170.5 167 169 172 177.4 MBh 60.8 61.5 63.2 65.7 60.3 61.0 62.7 65.2 58.8 59.6 61.3 63.8 56.4 57.1 58.8 61.3 53.3 54.1 55.8 58.3 50.6 51.4 53.0 55.5 S/T 1.00 1.00 0.77 0.6 1.00 1.00 0.77 0.6 1.00 1.00 0.80 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 0.7 1.00 1.00 1.00 1.0 AT 32 30 26 22 32 30 26 22 32 30 26 22 32 30 26 22 31 29 25 21 33 31 27 23 2250 kW 3.76 3.75 3.74 3.8 4.21 4.21 4.20 4.2 4.72 4.71 4.71 4.7 5.26 5.26 5.25 5.3 5.88 5.87 5.87 5.9 6.60 6.59 6.58 6.6 Amps 14.2 14.2 14.1 14.3 16.3 16.3 16.2 16.4 18.6 18.6 18.5 18.7 21.1 21.1 21.0 21.2 23.9 23.9 23.9 24.0 27.2 27.2 27.1 27.3 Hi PR 292 293 295 299.6 336 337 339 343.6 382 383 385 389.6 431 432 434 439.2 485 486 488 492.7 542 543 545 549.8 Lo PR 138 140 143 148.6 146 148 151 156.2 153 154 158 162.9 158 160 163 168.6 164 166 169 174.1 171 173 176 181.1 IDB: Entering Indoor Dry Bulb Temperature Shaded area reflects AHRI conditions High and low pressures are measured at the liquid and suction service valves. Amps = outdoor unit amps (comp.+fan) kW = Total system power k a z 0 m 0 n O O r_ z G1 n C) k z W z O N ja O O N 44 n PERFORMANCE DATA GSXN3N1810A*/CA*FA2422*6A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 520 CFM 75 18,250 12,300 5,950 1,240 80 18,050 12,150 5,900 1,310 85 17,800 12,000 5,800 1,380 90 95 17,400 000 11,750 5,650 1,460 100 16,550 11,150 5,400 1,620 105 16,050 10,850 5,200 1,700 110 15,650 10,550 5,100 1,800 115 15,200 10,250 4,950 1,890 TVA CONDITIONS @ 95" OD DB, 75' ID DB 63' ID WB 95° 16,400 11,500 4,900 1,530 GSXN3N3010A*/CA*FA3626*6A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1105 CFM 75 30,450 22,000 8,450 2,110 80 29,950 21,000 8,950 2,230 85 29,400 20,000 9,400 2,340 90 28,900 20,250 8,650 2,470 95 411 20,500 7,900 2,600 100 27,600 19,950 7,650 2,750 105 26,800 19,350 7,450 2,890 110 26,100 18,850 7,250 3,060 115 25,350 18,300 7,050 3,220 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95° 27,400 16,400 11,000 2,040 GSXN3N4210A*/CA*F4961*6A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1460 CFM OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75 42,350 30,950 11,400 2,860 80 41,850 30,600 11,250 3,030 85 41,300 30,200 11,100 3,190 90 40,400 29,550 10,850 3,370 95 1 28,850 10,650 3,550 100 38,400 28,050 10,350 3,760 105 37,300 27,250 10,050 3,960 110 36,300 26,500 9,800 4,200 115 35,300 25,750 9,550 4,430 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95' 38,100 28,950 9,150 3,560 GSXN3N6010A*/CA*T4961*4A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 1565 CFM OUTDOOR TOTAL SENSIBLE LATENT TOTAL 75 57,900 39,500 18,400 4,130 80 57,200 39,050 18,150 4,390 85 56,450 38,550 17,900 4,640 90 55,250 37,700 17,550 4,910 95 ICI 36,850 17,150 5,180 100 52,500 35,850 16,650 5,490 105 51,000 34,800 16,200 5,800 110 49,650 33,850 15,800 6,160 115 48,250 32,900 15,350 6,510 TVA Conditions @ 95° OD DB, 75° ID DB 63° ID WB 95' 52,050 36,950 15,100 5,190 GSXN3N2410A*/CA*TA2422*4A* CONDITIONS: 80 °F IBD, 67 °F IWB @ 800 CFM 75 24,250 16,550 7,700 1,660 80 23,950 16,350 7,600 1,750 85 23,650 16,100 7,550 1,840 90 23,150 15,750 7,400 1,940 95 00 15,400 7,200 2,030 100 22,000 15,000 7,000 2,140 105 21,350 14,550 6,800 2,250 110 20,800 14,150 6,650 2,380 115 20,200 13,750 6,450 2,510 TVA CONDITIONS @ 95" OD DB, 75° ID DB 63° ID WB 95° 21,800 15,450 6,350 2,030 GSXN3N3610A*/CA*FA4226*6A* CONDITIONS: 80 °F IBD. 67 °F IWB @ 1270 CFM 75 36,650 27,250 9,400 2,480 80 36,200 26,900 9,300 2,630 85 35,750 26,550 9,200 2,770 90 35,000 26,000 9,000 2,930 95 II 25,400 8,800 3,080 100 33,250 24,700 8,550 3,250 105 32,300 24,000 8,300 3,420 110 31,450 23,350 8,100 3,630 115 30,550 22,700 7,850 3,830 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95° 33,000 25,500 7,500 3,080 GSXN3N4810A*/CA*F4961*6A* CONDITIONS: 801 IBD. 67 °F IWB @ 1640 CFM 75 48,250 36,100 12,150 3,330 80 47,650 35,700 11,950 3,520 85 47,050 35,250 11,800 3,710 90 46,050 34,500 11,550 3,920 95 111 33,700 11,300 4,120 100 43,750 32,750 11,000 4,350 105 42,500 31,800 10,700 4,580 110 41,350 30,950 10,400 4,850 115 40,200 30,100 10,100 5,120 TVA CONDITIONS @ 95° OD DB, 75° ID DB 63° ID WB 95° 43,400 33,800 9,600 4,130 18 www.goodmanmfg.com SS-GSXN3 LP G) X z W E3 CONTROLBOX Q T1y T2TT0 Lip L2p ALTERNATE DOUBLE POLE CONTACTOR MAIN PU AUX BR 10 BK CM BUPK -Y ] SEE NOTE 1 BL -C SEE NOTE 3 SC 4 LVJB BL BK BK BK RD RD RD BUPK J T1 T2 RD I TT 1 Li L2p RD 1 COLOR CODE c BK ------- BLACK BL--------BLUE — — BUPK----- BLUE/PINK STRIPE BR ------- BROWN SWITCH (PRESS.) OR------ ORANGE RD PU------- PURPLE SWITCH (TEMP) OTO RD------- RED W H------- WHITE YL 1 PU I YL--------YELLOW C HERM YL RD F YL BR YL I WIRING CODE FACTORY WIRING =cC; HIGH VOLTAGE 1 SA LOW VOLTAGE FUSED) BL/PK OPTIONAL HIGH VOLTAGE--- NOTE2 BUPK RD FIELD WIRING HIGH VOLTAGE — — LOW VOLTAGE — COMP MAIN EQUIPMENT GROUND RD SEE NOTE 3 BK AUX - El-YL HPS 10 c s R OUTDOOR POWER SUPPLY SEE RATING PLATE I SEE NOTE 3 I T1 /'!C T2 L7 5 SR 2 1 \2 L 10 l H C PJ S 1 ZO RCCF 1 m COMP O O ai'gi,(, F W U R r� �� z z O J+ ` SA J W U 10 P (IF USED) J W Q 0 4 CM �qN HPS COMPONENTCODE Y c SEE NOTE 1 C-------- CONTACTOR SEE NOTE CM ------- OUTDOOR FAN MOTOR COMP ---- COMPRESSOR HPS ------ HIGH PRESSURE SWITCH 10-------INTERNAL OVERLOAD LVJB ----- LOW VOLTAGE JUNCTION BOX NOTES: RCCF ----- RUN CAPACITOR FOR COMPRESSOR & FAN 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL SA------- START ASSIST BLOCK AND INDOOR THERMOSTAT. SC ------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) USE N.E.C. CLASS 2 WIRE. SR------- START RELAY FOR COMPRESSOR (OPTIONAL) 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. CONTROLS SHOWN WITH THERMOSTAT IN'OFF' POSITION. 3) USE COPPER CONDUCTORS ONLY. 0140R00603-B Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power refer to the wiring diagram or the I 7 WARNING sources may be present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. E z c) _Q N z UJ z N 00 N NJ N -p I� n U0 w 0 0 N O CONTROLBOX 1 1 I BK SR 5 1 2 BLS 'L Q T1T0 T2T0 �fb� L110 L210 ALTERNATE DOUBLE POLE CONTACTOR MAIN --'M AUX --,m IO CM BK I I COMP MAIN ID BK AUX 000 YL C $ R 1 SC 1 4 BK rB�K RD BL D K RD —J RD1 WYL K RCCF —YLI i SA (IF USED) NOTE — -RD CRAM EQUIPMENT GROUND SEE NOTE 3 —Y] SEE NOTE 1 C SEE NOTE 3 LVJB COLOR CODE BK--------BLACK BL------- BLUE BR ------- BROWN OR ------- ORANGE PU------- PURPLE RD------- RED W H -----_WHITE YL ----- YELLOW WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE FIELD WIRING HIGH VOLTAGE COMPONENT CODE C ----- CONTACTOR CH------ CRANKCASE HEATER CHS------ CRANKCASE HEATER SWITCH CM ------OUTDOOR FAN MOTOR COMP ---- COMPRESSOR DT------ DISCHARGE THERMOSTAT 10 ----- INTERNAL OVERLOAD LVJB -- LOW VOLTAGE JUNCTION BOX RCCF --- RUN CAPACITOR FOR COMPRESSOR & FAN SA ------ START ASSIST SC ----- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SIR ----- START RELAY FOR COMPRESSOR (OPTIONAL) CONTROLS SHOWN WITH THERMOSTAT IN'OFFPOSITION. IOUTDOOR POWER SUPPLY I SEE RATING PLATE SEE NOTE 3 I T1 L1 5 2 1 T2 C J w z m O O SR 0 C PJ� S COMP Mq� SC H C RCCF C I w O I 4 Z I w a 3K R 1 F J US 10 P (IF USED) 9j I I BK I M CH CHS O GR C Y C SEE NOTE 3 SEE NOTE 1 NOTES 1) TO INDOOR UNIT LOW VOLTAGE TERMINAL BLOCK & INDOOR THERMOSTAT.USE N.E.C. CLASS 2 WIRE, 2) START ASSIST FACTORY EQUIPPED WHEN REQUIRED. 3) USE COPPER CONDUCTORS ONLY. Wiring is subject to change. Always High Voltage: Disconnect all power before servicing or installing this unit. Multiple power L refer to the wiring diagram or the I 7 WARNING sources maybe present. Failure to do so may cause property damage, personal injury, or death. unit for the most up-to-date wiring. 0140R01003-A DIMENSIONS MODEL DIMENSIONS W" D" H» GSXN3N1810A* 26 26 27 GSXN3N2410A* 26 26 32% GSXN3N3010A* 29 29 32% GSXN3N3610A* 29 29 32'/= GSXN3N4210A* 29 29 39% GSXN3N4810A* 35% 35% 35% GSXN3N6010A* 35% 35% 39% *Note: All the Dimensions (W, D, H) are for reference only. ACCESSORIES MODEL ABK-20 Anchor Bracket Kit ^ X X X X X X X ABK-21 Anchor Bracket Kit A ASC-01 Anti -Short Cycle Kit X X X X X X X CSR-U-1 Hard -start Kit X X X X CSR-U-2 Hard -start Kit X X X X CSR-U-3 Hard -start Kit X X FSK01A' Freeze Protection Kit X X X X X X X LSK02A2 Liquid Line Solenoid Kit X X X X X X X LAKT01 Low -Ambient Kit X X X X X X 0130R00000S Low -Pressure Switch Kit X X X X X X X TXV-FX-KX-2T z TXV Kit X X TXV-FX-KX-3T Z TXV Kit X X TXV-FX-KX-5T z TXV Kit X X X Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil 2 Field -installed, non -bleed, expansion valve kit: Condensing units and heat pumps with reciprocating or rotary compressors require the use of start -assist components when used in conjunction with an indoor coil using a non -bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit. All AHRI system ratings are accessible in the System Configurator tool via Partnerl-ink. SS-GSXN3 www.goodmanmfg.com 21 NOTES 22 www.goodmanmfg.com SS-GSXN3 NOTES 23 SS-GSXN3 www.goodmmaw.g%cDiyrtanmfg.com SS-GSXN3 23 NOTES Our continuing commitment to quality products may mean a change in specifications without notice. ©2022 DA/K/NCOMFORTTECNNOLOG/ESMANUFACTUR/NG.L.P. • Houstonjexas • Printed in the USA. 24 www.goodmanmfg.com SS-GSXN3