Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2023-1009_Manufacturer_Specifications_and_Installation_Instructions_8.10.2023_8.55.43_AM_3718012
Job Name: System Reference: Date: Indoor Unit SVZ-KP24NA Unit, ............................................................................ Outdoor Unit SUZ-KA24NAHZ ..................................................................... illllllllillllllllllllllio�"'°`"� ullllllllllllllllllllllllllllllllllllllli�,,, ^ III�II�I�I�I�II!�III��II�I�II�,: a IIIIIIIIIIIIIIIIIII�IIIIIIIIII�IIIIIIIIP ,� ''��IIIIIIIIIIIIIIIIII�IIIIII�''' ;, �" mttllllll1111nn� �s —I I INDOOR UNIT FEATURES • Ducted air handler provides a solution to cool and heat large zones • Highly efficient totally enclosed ECM motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and boosts efficiency • Positive pressure cabinet with air leakage of less than 2.0% at 1.0 In.WG (Tested per ASHRAE Standard 193) • Unique blow through design allows simple coil cleaning when the blower is removed • Multi -position installation: horizontal (left or right), vertical (up or down) • Optional electric heat kit for additional heat capacity • Optional humidifier control and ERV control • Built-in humidifier control, ERV control and auxiliary heat control • Optional downflow kit • Multiple control options available: o kumo cloud° smart device app for remote access o Third -party interface options o Wired or wireless controllers OUTDOOR UNIT FEATURES • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER -driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • H2i® hyper heat performance offers 100% heating capacity at 5° F • Hot -Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Built-in base pan heater • Innovative Joint Lap DC Motor leads to high efficiency and reliability • Pulse Amplitude Modulation technology Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling at 95°F' Maximum Capacity Rated Capacity Minimum Capacity Maximum Power Input BTU/H 24,000 BTU/H 24,000 BTU/H 8,800 W 2,420 Rated Power Input W 2,420 Moisture Removal Pints/h 4.7 Sensible Heat Factor 0.78 Power Factor % 97.0/97.0 Heating at 47°F' Maximum Capacity BTU/H 28,800 Rated Capacity BTU/H 23,000 Minimum Capacity BTU/H 9,400 Maximum Power Input W 2,790 Rated Power Input W 2,140 Power Factor % 97.0/97.0 Heating at 17°F' Maximum Capacity BTU/H 23,000 Rated Capacity BTU/H 19,200 Maximum Power Input W 3,700 Rated Power Input W 2,566 Heating at 5°F" Maximum Capacity BTU/H 23,000 Maximum Power Input W 4,146 Heating at -13°F7 Maximum Capacity BTU/H 18,400 Efficiency SEER 16.0 EER' 9.9 HSPF [IV] 9.2 COP at 47°F2 3.1 COP at 170Fat Maximum Capacity' 1.8 COP at 5°F at Maximum Capacity' 1.6 COP at -13°F at Maximum Capacity' 1.2 ENERGY STAR® Certified No Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 25 Recommended Wire Size [Indoor - Outdoor] AWG 14 Indoor Unit MCA A 3.0 Fan Motor Full Load Amperage A 2.4 Fan Motor Output W 121 Airflow Rate at Cooling, Dry CFM 515-625-735 Airflow Rate at Heating, Dry CFM 515-625-735 Sound Pressure Level [Cooling] dB[A] 33-36-41 Sound Pressure Level [Heating] dB[A] 33-36-41 External Static Pressure in.WG 0.30-0.5-0.8 Drain Pipe Size In. [mm] 3/4 [19.05] Coating on Heat Exchanger — External Finish Color Hat -dip coated steel (ZAM) Unit Dimensions W x D x H: In. [mm] 17 x 21-5/8 x 39-13/16 [432 x 549 x 1011] Package Dimensions W x D x H: In. [mm] 18 x 28-3/4 x 44-3/8 [460 x 730 x 1127] Unit Weight Lbs. [kg] 93 [42] Package Weight Lbs. [kg] 106 [48] Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 95 DB, 71 WB / 67 DB, 57 WB Heating Intake Air Temp [Maximum / Minimum] °F 80 DB / 70 DB NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 'Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions °Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor H Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 'Heating at -5°F (Indoor H Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor H Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. • For P-Series only: » Wind baffles required to operate below 23°F DB in cooling mode. • Cooling -only system with wind baffle: -40°F - 115°F. n Heat pump system with wind baffle: 0°F - 115°F. • Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (ONLY APPLIES TO P-SERIES -BS MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor Unit MCA MOCP A 17.0 A 27 74 Fan Motor Output Airflow Rate W CFM 800/800 Refrigerant Control LEV Defrost Method Reverse Cycle Sound Pressure Level, Cooling' dB(A) 52 Sound Pressure Level, Heating2 dB(A) 53 Compressor Type Scroll Compressor Model DNB28FBAMT Compressor Rated Load Amps A 9.0 Compressor Locked Rotor Amps A 18.0 Compressor Oil Type // Charge oz. FVC68D 111,34 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater Built-in Unit Dimensions W x D x H: In. [mm] 37-13/32 x 14-3/16 x 37-1/8 [950 x 360 x 9431 Package Dimensions W x D x H: In. [mm] 41 x 18 x 41 [1040 x 450 x 1033] Unit Weight Lbs. [kg] 190 [86] Package Weight Lbs. [kg] 210 [95] Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB / 0 DB Heating Air Temp [Maximum / Minimum] °F 75 DB, 65 WB / -13 DB, -14 WB Heating Thermal Lock -out / Re -start Temperatures** °F -22 / -13 Refrigerant Type R410A Charge Lbs, oz 7,11 Chargeless Piping Length Ft. [m] 70 [21.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.7 [65] Piping Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88] Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52] Maximum Piping Length Ft. [m] 165 [50] Maximum Height Difference Ft. [m] 100 [30] Maximum Number of Bends 15 NOTES: AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB 3Heating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions +Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB H 5 DB, 4 WB sHeating at -4°F (Indoor H Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB 'Heating at -5°F (Indoor H Outdoor) °F 70 DB, 60 WB // -5 DB, -6 WB 7Heating at -13°F (Indoor H Outdoor) °F 70 DB, 60 WB // -13 DB, -14 WB *Outdoor Unit Operating Temperature Range (Cooling Air Temp (Maximum / Minimum)): • Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. • For P-Series only: • Wind baffles required to operate below 23°F DB in cooling mode. • Cooling -only system with wind baffle: -40°F - 115°F. n Heat pump system with wind baffle: 0°F - 115°F. » Refer to wind baffle documentation for further information. **Outdoor Unit Operating Temperature Range (Cooling Thermal Lock -out / Re -start Temperatures; Heating Thermal Lock -out / Re -start Temperatures): • System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SEACOAST PROTECTION (ONLYAPPLIES TO P-SERIES -BS MODELS) External Outer Panel: Phosphate coating +Acrylic -Enamel coating • Fan Motor Support: Epoxy resin coating (at edge face) • Separator Assembly Valve Bed: Epoxy resin coating (at edge face) Blue Fin treatment is an anti -corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants. Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Control Interface BACnet® and Modbus Interface CN24 Relay Kit Connector cable for remote display IT Extender kumo station® for kumo cloud® Remote Operation Adapter$ Thermostat Interface USNAP Adapter Wireless Interface for kumo cloud® ❑ PAC-UKPRC001-CN-1 ❑ CN24RELAY-KIT-CM3 ❑ PAC-SA88HA-EP ❑ PAC-WHS011E-E ❑ PAC-WHS01 HC-E ❑ PAC-SF40RM-E ❑ PAC-US444CN-1 ❑ PAC-WHS01UP-E ❑ PAC-USWHS002-WF-2 Flush Mount Temperature Sensor ❑ PAC-USSEN001-FM-1 Remote Sensor Remote Temperature Sensor surface mount ❑ PAC-SE41 TS-E Wireless temperature and humitity sensor for kumo cloud® ❑ PAC-USWHS003-TH-1 Airzone ZBS Wired Blueface Principal Controller White ❑ AZZBSBLUEFACECB Airzone ZBS Wired Lite Controller White ❑ AZZBSLITECB Airzone ZBS Wired Think Controller White ❑ AZZBSTHINKCB Airzone ZBS Wireless Lite Controller White ❑ AZZBSLITERB Wired Remote Controller Airzone ZBS Wireless Think Controller White ❑ AZZBSTHINKRB Deluxe Wired MA Remote Controllert ❑ PAR-40MAAU Simple MA Remote Controllert ❑ PAC-YT53CRAU-J Touch MA Controllert ❑ PAR-CT01 MAU-SB kumo touch" RedLINK" Wireless Controller ❑ MHK2 Wireless Remote Controller Wireless MA Receiver ❑ PAR-FA32MA-W Wireless MA Remote Controller ❑ PAR-FL32MA-E Condensate Blue Diamond Sensor Extension Cable —15 Ft. ❑ C13-103 20/2PR, 1 PR shielded + 1 PR plenum wire forAirzone, 100 ft reel ❑ CW2042S2-100 Control Wire 20/2PR, shielded + 1PR plenum wire for Airzone, 500 It reel ❑ CW2042S2-500 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Downflow Kit Downflow Kit ❑ DFK-S Electric Heat Lockout Electric Heat Lockout ❑ ETC-211000-MIT 3kW Electric Heater Module - Small Cabinet, SVZ ❑ EH03-SVZ-S Electric Kit Heats 5kW Electric Heater Module - Small Cabinet, SVZ ❑ EH05-SVZ-S 8kW Electric Heater Module - Small Cabinet, SVZ ❑ EH08-SVZ-S 10' x 3/8" x 10' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-10 100' x 3/8" x 100' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-100 15' x 3/8" x 15' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-15 Lineset 30' x 3/8" x 30' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-30 50' x 3/8" x 50' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-50 65' x 3/8" x 65' x 5/8" Lineset (Twin -Tube Insulation) ❑ MPLS385812T-65 Terminal Block Separate Terminal Power Block ❑ SPTB1 NOTES: tRequires MAC-3341F-E • M-Series EZ FIT® Recessed Ceiling Cassette, Floor -mount and Wall -mount Allows indoor units to connect to an MA Controller: Deluxe MA Remote Controller Simple MA Controller Touch MA Controller tPAC-SF40RM-E (Unable to use with wireless remote controller) M-Series Ceiling Cassette, Ceiling Suspended, Horizontal -ducted and Multi -position Air Handler • P-Series Ceiling Cassette, Ceiling Suspended, Horizontal -ducted and Multi -position Air Handler Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide Air Outlet Guide (1 Piece) Centralized Drain Pan Drain Pan Control/Service Tool M- & P-Series Maintenance Tool Cable Set Drain Socket Drain Socket Hail Guards Hail Guard Mounting Pad Condensing Unit Mounting Pad: 24" x 42" x 3" Stand 18" Single Fan Stand 24" Single Fan Stand Outdoor Unit Stand —12" High ❑ PAC-SG59SG-E ❑ PAC-SG64DS-E ❑ M21EC0397 ❑ PAC-SH71DS-E ❑ HG-A6 ❑ ULTRILITE2 ❑ QSMS1801M ❑ QSMS2401M ❑ QSMS1201M Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. o26 Knockout Hole (Indoor / Outdoor unit connection) (Remote controller transmission) Left side view Unit:mm(in.) view o26 Knockout Hole 026 Knockout Hole for electrical heat wiring 2-o4.6 Burring Holes for electric heat installation IIL Secondary nining) 19.05(3/4) 3/4"FPT- left) Secontlary drain pipe Secondary drain pipe (oEm.ngency Craning) (Emergency draining) t 9.05(3/4) 3/4"FPT o19.05(3/4) 3/4"FPT (Horl—tal Right) Model Nominal Filter Size Duct Connection SVZ-KP12NA 508 x 406.4 x 25.4 (20 x 16 x 1) 376 x 402 (14-13/16 x 15-7/8) SVZ-KP18NA SVZ-KP24NA SVZ-KP30NA 508 x 508 x 25.4 (20 x 20 x 1) 477 x 402 (18-13/16 x 15-7/8) SVZ-KP36NA Bottom Tr view ]J Prima�rr(vyv drain)pipe 019 0 (3/4) 374"FPT Control box "(Remove Blower Panel) Unit:mm(in.) Note: Electrical entrance for SVZ located on both left and right side of the cabinet. See right or Left side view for knockout locations. Right side view Model A B C D E F G H J Gas Pipe Liquid pipe SVZ-KP12NA 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8-7/8) 1,010.8 (39-13/16) 680 (26-13/16) 823 (32-7/16) 735.5 (29) 360 (14-3/16) o 9.52 (3/8) o 6.35 (1/4) SVZ-KP18NA 0 12 7 (1/2) SVZ-KP24NA SVZ-KP30NA 534 (21) 477 (18-13/16) 382.6 (15-1/8) 266.5 (10-1/2) 1,113.8 (43-7/8) 737 (29-1/16) 953.5 (37-9/16) 792 (31-3/16) 461 (18-3/16) o 15.88 (5/8) o 9.52 (3/8) SVZ-KP36NA Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 0 N N OD (D O OW w< �v N N Cn N 7 CD CID o S /1\ < D rD m �1 P w � ° N FREE SPACE (Around the unit) The diagram below shows a basic example. Explanation of particular details are given jn the installation manuals etc. 2 SERVICE SPACE 3 FOUNDATION BOLTS 14 PIPING -WIRING DIRECTIONS Dimensions of space needed Please secure the unit firmly Piping and wiring connections for service access are with 4 foundation (M10<W3/8>) balls. can be made from 4 directions: shown in the below diagram. (Bolts and washers must be FRONT, Right, Rear and Below. purchased locally.) Example of Notes O1 Refrigerant GAS pipe connection (FL ARE)015.88(5/8F ). Q -Refrigerant LIQUID pipe connection (FLARE)09.52(3/8F). '1 -Indication of VALVE connection location. Piping Knock -Out Hole Detoiles ,Foundation halt height, �m wne sf nra me Oman serene n m ,h me vz ca�au mma.em m j i I i - I i - I Side Ar Make 1