EOR stamped and signed top supported retaining wallTOP -SUPPORTED RETAINING WALL DETAIL
SUPPORTED WALL
BACKFILL HEIGHT A13
LE55 THAN 7'-6" 14" 18"
... — .......... .......... __
7'-6" TO 8'-0" 12" 18"
8'-9" TO 9'-0" 12" 18"
9'-1" TO 10'-0" 10" 18"
NOTE5:
REBAR Fy = 60,00 P5I
CONCRETE F' c = 2,500 P5I
2' FROM GARAGE SLAB OR 5IDEWALK
8' MIN FROM FG
GARAGE SLAB OR FG'
EXTERIOR WALL CON5TRUCTION
5/8" X 10" ANCHOR BOLT @ 32" O.C.
4X PLATE UNDER J0I5T
TYP FLOOR
CON5TRUCTION
242" RIGID IN5ULATION (N.I.C;
2X4 FURRED WALL W/'$
R2 F.G. BATT IN5UL (N.I.C.)
WHERE INDICATED i,
VERTICAL 5TEEL"A" #5 BAR5 PER SCHEDULE
HORIZONTAL 5TEEL "B" #4y"d
BAR5 PER SCHEDULE �y 2" CLEAR
APPLY DAMPPROOFING TO
FOUNDATION BELOW GRADE
R,
8" THICK REINFORCED CONCRETE FOUNDATION WALL 4" CONC. SLAB
_ 6 MIL POLY VB
s 6" COMPACTED
24" #4 @ 18" O.C. , GRANULAR FILL
811�
4" PERIMTER DRAIN TILE
EXT. WALL W/ 6" MIN DRAIN ROCK ,
CONSTRUCTION 18"X8" CONC. FTG_ .......-
5/8" X 10" ANCHOR BOLT 32" O.C. 3 #5 CONT N PLAN
4X PLATE UNDER J0I5T --
SOLID BLOCK 48" O.C., CARRY BLOCKING TO A
LENGTH OF 12' MIN FROM RETAINING WALL. ATTACH
_ A---�PLYWOOF) SHEATHING TO TOP OF BLOCKING WITH 10d
L NAIL5 @ 6" O.C.
� j!�:— A34 REINFORCING ANGLE EA. 5IDE OF BLOCK (U5E
2-A34 EA. 5IDE WHERE WALL HEIGHT>= 10')
SUPPORT OF TOP OF WALL WHERE JOISTS RUN PARALLEL
TO WALL
cd?
CJR Engineering :oAs J. Ross PROJECT:
LYNNWOOD WA 98087 Gv���F WA�C�l
TOP SUPPORTED
Ph: (425) 269-5204 � BASEMENT RETAINING
Fx: (425) 671-0003 WALL
email: info@c ren com �� 29133
9 o� ?F�rsiEg��w EASTMAN KING
�SSIONAL���� /19/22 RESIDENCIAL BUILDING
From: Carter, Eric <Eric.Carter@edmondswa.gov>
Sent: Thursday, May 19, 2022 8:46 AM
To: Dillon Aschenbrenner <dillon@indepthex.com>
Cc: Sue Eastman King <eastperson@icloud.com>; Nelson, Denise <Denise.Nelson @edmondswa.gov>
Subject: Re: EVEN MORE URGENT: Additional Information
Dillion,
The email will suffice for the time being but we will need a stamped RFI, upon the EOR's return.
Thank you,
Eric Carter
Building Inspector
City of Edmonds
On May 19, 2022, at 8:24 AM, Dillon Aschenbrenner <dilIon @indepthex.com> wrote:
Eric,
Does this work? Seems like the detail for "supported wall" some dropped off the plans.
Sent from my Whone
Begin forwarded message:
From: "Clemens J. Rossell, P.E." <clemens@clreng.com>
Date: May 19, 2022 at 7:36:21 AM PDT
To: Dillon Aschenbrenner <dillon@indepthex.com>
Cc: Sue Eastman King <eastperson@icloud.com>, Amy Peri <aperi@linwoodhomes.com>, Luke Sigler
<sigler2607@comcast.net>, John Rientjes <irientles@gmail.com>, Jerry <GeraldEKing@icloud.com>
Subject: Re: EVEN MORE URGENT: Additional Information
This is the detail, you may show this email to the inspector as proof that it comes from me. I
can send a stamped copy later today, but at the moment I am on an excursion in Portugal away
from my laptop, responding to this from my phone, so I cannot add my stamp right now.
Hope this helps,
Clemens
Clemens J. Rossell, P.E.
CJR Engineering
On Thu, May 19, 2022, at 2:38 PM, Dillon Aschenbrenner wrote:
The city's plans and my approved plans do not have the "supported wall" detail on them. It is blank. I
understand what walls are what but the inspector can not inspect supported wall without the detail.
Sent from my iPhone
On May 19, 2022, at 12:16 AM, Clemens J. Rossell, P.E. <clemens@cireng.com> wrote:
If the walls will end up retaining soil (or, if retaining soil on both sides of the wall the finish grade
elevation on one side is higher than at the other side of the wall and the difference in height is 4'
or higher) the wall is a retaining wall and needs to be constructed per my engineering details. I
provided two different wall details for this project, the top supported retaining wall, where the
concrete wall goes full height and is connected to the floor at the top, and supported by the floor
at the top per the connection detail, and also a detail for a stepped -down wall where the
concrete does not extend to the floor but stops at some point between the footing and the floor,
and has a concrete pony wall on top. This latter type is a cantilever retaining wall, does not
require connection of the concrete to the floor (since it does not reach that height) but it requires
a much larger, more heavily reinforced footing, detailed to keep the wall stable against
overturning and sliding.
The cross sections for the house for the locations circled in red appear to indicate concrete
walls going all the way to the floor and that will retain soil on the exterior of the basement. For
reference I am including the cross sections that I see on the version of the drawings called v6
that may be the latest or one of the latest.
Thanks,
Clemens
Clemens J. Rossell, P.E.
CJR Engineering
On Wed, May 18, 2022, at 1:43 PM, Sue Eastman King wrote:
Dillon also found these notations that probably need to be addressed.