Loading...
REVIEWED BLD BLD2021-0895+Energy_Calculations+6.26.2021_10.26.20_AM+2271130BLD2021-0895 RECEIVED iple Heating System Size: Washington State Jul 16 2021 heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and CITY OF EDMONDS A Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine D VELOPMENT SERVICES iciloads. I DEPARTMENT Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information 131 Skyline Drive John Rientjes Edmonds, WA 425-864-3049 jrientjes@gmail.com Heating System Type: Q All other systems • Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Instructions Design Temperature Difference (AT) 46 Edmonds AT = Indoor (70 degrees) - Outdoor Design Temp Area of Buildinq Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 3,700 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 9.0 33,300 Glazing and Doors U-Factor X Area = UA Instructions �FED .30 Ell 0.300 527 158.10 Skylights U-Factor X Area = UA Instructions 0.50 Insulation Attic U-Factor X Area = UA Instructions R-49 Ell 0.026 2,680 69.68 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions Select R-Value - 4 No selection --- Above Grade Walls (seeFigurel) U-Factor X Area UA Instructions I R-21 Intermediate 0.056 2,997 167.83 Floors U-Factor X Area UA Instructions R-30 I J 0.029 2,163 62.73 Below Grade Walls (see Figure1) U-Factor X Area UA Instructions R-21 Interior I J 0.042 792 33.26 Slab Below Grade (see Figure p F-Factor X Length UA Instructions R-10 Fully insulated I 0.303 1,537 465.71 Slab on Grade (see Figure1) F-Factor X Length UA Instructions Select R-Value No selection --- Location of Ducts Instructions Duct Leakage Coefficient - Unconditioned Space L 1.10 Sum of UA 957.31 Envelope Heat Load 44,036 Btu / Hour Ficiure 1. Sum of UA x AT Air Leakage Heat Load 16,543 Btu / Hour Volume x 0.6 x AT x 0.018 Above Grade Building Design Heat Load 60,580 Btu / Hour Airleakage + envelope heat loss Building and Duct Heat Load 66,638 Btu / Hour Ducts in unconditioned space: sum of buildina heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 83,297 Btu / Hour Buildina and duct heat loss x 1.40 forforced airfumace Buildina and duct heat loss x 1.25 for heat DumD (07101113)