Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
DNS-REVIEWED-WINDOW GLAZING SPECS AND TESTING
Lntertclk Total Quality. Assured. MADIC0, INC. TES i REP( SCOPE OF WORK SAFETY GLAZING MATERIAL TESTING OF CL 800 PS SR FILM ON 1/4" GLASS REPORT NUMBER 17039.16-119-37 TEST DATE 07/24/18 ISSUE DATE 09/05/18 RECORD RETENTION END DATE 07/24/22 PAGES 5 DOCUMENT CONTROL NUMBER ATI 00854 (08/07/17) RT-R-AM E R-Test-2889 © 2017 INTERTEK Lntertek Total Quality. Assured. TEST REPORT FOR MADICO, INC. Report No.: 17039.16-119-37 Date: 09/05/18 ...nF?T ICCI IED TO MADICO, INC. 64 Industrial Parkway Woburn, Massachusetts 01801 SCOPE 130 Derry Court York, Pennsylvania 17406 Telephone: 717-7 64-7 700 Facsimile: 717-764-4129 www.intertek.com/building Intertek Building & Construction (B&C) was contracted by Madico, Inc. - Woburn, Massachusetts to perform safety glazing material performance testing in accordance with ANSI Z97.1 and CPSC 16 CFR 1201 on their CL 800 PS SR Film on 1/4" thick annealed glass. Results obtained are tested values and were secured by using the designated test methods. Testing was conducted at the Intertek B&C test facility in York, Pennsylvania. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. L /"TIl11�1 ' SUMMARY OF TEST RESULTS Film: CL 800 PS SR Glass: 1/4" annealed glass Glazing Type: Organic Coated Glass IMPACT TEST RESULTS STANDARD CLASSIFICATION ANSI Class A CPSC Category II DROP HEIGHT RESULT' 48 in. (1219 mm) Pass 48 in. (1219 mm) Pass 'The performance evaluation of the product identified in this test report was isolated to impact testing only, accelerated weathering/aging and thermal tests were not performed. For INTERTEK B&C: COMPLETED BY: Todd M. Wilt TITLE: Lead Technician rn k) +lw SIGNATURE: ogTro DATE: 09/05/18 TM W:vtm/aaa REVIEWED BY: Virgal T. Mickley, Jr., P.E. TITLE: Senior Staff Engineer A--*// SIGNATURE: sg�ey:Mgw � El i icw DATE: 09/05/18 This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of ACCREDITED` the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample(s) tested. This report by itself does not imply that the material, product, resting or service is or has ever been under an Intertek certification program. Laboratory Version: 08/07/17 Page 2 of 5 RT-R-AMER-Test-2889 Lntertek Total Quality. Assured. TEST REPORT FOR MADICO, INC. Report No.: 17039.16-119-37 Date: 09/05/18 SFrT1nni - TEST METHOD(S) 130 Derry Court York, Pennsylvania 17406 Telephone: 717-7 64-7 700 Facsimile: 717-764-4129 www.intertek.com/building The specimens were evaluated in accordance with the following: ANSI Z97.1-2015, For safety glazing materials used in buildings - safety performance specifications and methods of test, American National Standard CPSC 16 CFR 1201, Safety Standard for Architectural Glazing Materials, Consumer Product Safety Commission (16 CFR Ch. 11, 1-1-03 Edition) SECTION 4 MATERIAL SOURCE Clear, annealed glass lites with CL 800 PS SR Film were delivered to Intertek from Madico, Inc. on 07/18/18. The specimens were conditioned before and during testing between 68' to 857. SECTION r SAMPLE RETENTION All test specimens were destroyed by test or by personnel and have been disposed of as trash. SECTION 6 EQUIPMENT ASSET # DESCRIPTION CAL DUE DATE 63303 Impact Frame 09/22/18 65882 Impactor (1001b.) 11/22/18 65852 Calipers/Thickness Gauge 09/13/18 INT00433 Thermometer 01/28/19 62039 Weight Scale 09/13/18 Version: 08/07/17 Page 3 of 5 RT-R-AMER-Test-2889 Lntertek Total Quality. Assured. TEST REPORT FOR MADICO, INC. Report No.: 17039.16-119-37 Date: 09/05/18 SFrT1nni — LIST OF OFFICIAL OBSERVERS NAME Lance Cullen Todd M. Wilt Cory E. Straub SECTION E TEST PROCEDURE COMPANY Madico, Inc. Intertek B&C Intertek B&C 130 Derry Court York, Pennsylvania 17406 Telephone: 717-7 64-7 700 Facsimile: 717-764-4129 www.intertek.com/building 0 Specimens were clamped into a steel frame and impacted with a 100 Lb. impactor from a drop height of 48 inches from the center of the impactor to the centerline of the test specimen. Specimens were examined for openings and glass loss after impact in accordance with the interpretation of results per the referenced standards. SECTION TEST SPECIMEN DESCRIPTION Product: CL 800 PS SR on 1/4" Glass Glazing Type: Organic Coated Glass Glass Type: Clear Annealed Glass Size Classification: Unlimited (U) Glass Manufacturer: Unknown Film/Organic Coating Manufacturer: Madico, Inc. - Woburn, Massachusetts Film/Organic Coating Brand Name: CL 800 PS SR Film Thicknesses: 8 mil Nominal Glass Thickness: 1/4" Sample Dimensions: 34" wide x 76" high (Impact) Glazing Composition Details THICKNESS (in.) Overall Glass Film 0.239 0.231 0.008 Method of Film Measurement: The overall glazing thickness was measured, then the film was separated and removed and the glass thickness, exclusive of the film, was measured. The film thickness was calculated by subtracting the measured glass thickness from the measured overall thickness. Version: 08/07/17 Page 4 of 5 RT-R-AMER-Test-2889 Lntertek Total Quality. Assured. TEST REPORT FOR MADICO, INC. Report No.: 17039.16-119-37 Date:09/05/18 TEST RESULTS Test Date: 07/24/18 Lab Temperature: 71°F Impact Drop Height: 48 inches IMPACT SPECIMEN THICKNESS SIDE NUMBER (IN.) (G / F)1 1 0.239 G 2 0.239 G 3 0.240 F 4 0.240 F OBSERVATIONS No openings No openings No openings No openings LARGEST FRAGMENT N/A 9.5g N/A N/A 130 Derry Court York, Pennsylvania 17406 Telephone: 717-7 64-7 700 Facsimile: 717-764-4129 www.intertek.com/building TOTAL PASS/ FRAGMENTS FAIL N/A Pass 9.5g Pass N/A Pass N/A Pass 1Impact Side: G = Glass Side Impacted F = Film/Organic Coated Side Impacted Acceptance Criterion: Limit No detached fragments over 1 inZ. 9.09 grams No single detached particle shall weigh more than 6.82 inZ. 62.03 grams Total weight of detached particles >1 inZ shall not weigh more than 15.5 inZ. 140.97 grams No shear or opening through which a 3" sphere can freely pass with 4 lbs. force. Note 1: Acceptance criteria limits were calculated using the nominal glass thickness identified in the 'Glazing Composition Details' section. Note 2: The 'Limit' presented for each item in the 'Impact Test Acceptance Criteria' identifies the allowable weight of the particle/fragment size for the specified item in the 'Criterion' section. SECTION 11 CONCLUSION The specimens meet the impact performance requirements set forth in the referenced test procedures. SECTION 1� REVISION LOG REVISION # 0 09/05/18 PAGES ■ N/A Original Report Issue Version: 08/07/17 Page 5 of 5 RT-R-AMER-Test-2889