Loading...
APPROVED BLD CC BLD2022-0736 PLANS0 N N N 0 N N In i IL U U U C 0 w F_ 0 0 N Q I U IL U U U 0 w r- 0 0 N i U) 0 O U) 1-1 U) 0) 0 N N 0 N [Roo�r�oo � D Storage=uilding EdmondsCivic4enter Playfield Aw(:@o l�]� 09 �d fnO�C��9 WA 9)6020 Applicable Codes: .......................... WASHINGTON: 2018 International Building Code with WA Amendments 2018 Uniform Plumbing Code by IAPMO with WA Amendments 2020 National Electrical Code with WA Amendments 2018 Washington State Energy Code 2009 ICC A117.1 Accessibility Standard Type of Construction: ...................... VB ❑ NO EXCEPTIONS NOTED ❑ MOT REVIEWED UTILITY BOX MARKED SEWER ❑ REVISE AND RESUBMIT ❑ 31SAPPROVEUITHIN 6' OF BUILDING Description: ...................................... Park Restroom ❑X REVIEWED AND PROCEED AS NOTED--- Occupancy: U Reviewed only for general conformance with th design concept of the Project and general compliance with the i formation given in the Contract Documents. This review dos not affect the Floor Area: ....................................... 813 - square feet Contractor's responsibility to perform all Co tract requirements with no changes in Contract price or time. Any actions shown are Gross Wall Area: ............................... 1162 - square feet subject to the requirements of the Contract Documents. Contractor is responsible to confirm and correlate dimen ions at the site; for Climate Zone: 4C information that pertains solely to the fabricatic n processes; for the .................................... means, methods, techniques, procedures, segUI nces and quantities necessary to complete the Contract; and ffir coordination of Blazer Job Number: ......................... 20076 the work of all trades and the satisfactory p rformance of their work. Any review is undertaken solely to satisfy Landscape PRC Project Number: ..................... 10967 Architect's obligations, if any, to the Owner an /or Client and shall not give rise to any claim by the Contract r or other parties against Landscape Architect, Owner, or Client. 0 0 o BY Jason Bril DAT 05/12/2022 PUMP BACKWASH UTILITY BOX DRAIN CONNECTION IJ W MARKED "WATER" WITHIN 6' OF BUILDING o�g T-1 Title Sheet. AC Accessibility Compliance. A-1 Floor Plan, Structural Design, Door Schedule. A-1.1 Sections, Roof Framing Plan. UTILITY BOX A-2 Exterior Elevations, Exterior Finish Schedule. _E MARKED "ELECTRICAL" WITHIN 6' OF BUILDING A-3 Interior Elevations, Interior Finish & Accessories Schedules. A-4 Details, Fastening Schedule. A-5 Cap Beam Plan & Details. M-1 Mechanical Plan & Information. P-1 Plumbing Plan & Information. E-1 Electrical Power Plan. E-2 Electrical Lighting Plan. E-3 Electrical Panel Schedule and Calcs. a 0 WALKER MACY I PORTLAND, OR I SEATTLE, WA S-1 Slab Plan. 503.228.3122 1 206.582.3874 1 WWW.WALKERMACY.COM • The structural design details herein are specific to the building size and module configuration ° shown on the floor plan of these drawings. p ° ° I p � 0 Oa0 • This building will be sited a minimum of 10 feet from all property lines and 10 feet from any O O Q 0 RECEIVED assumed property lines between existing structures on site. Jun 13 2022 • This building has no heating or cooling. Local jurisdiction to verify acceptability of no insulation CILOPM ETSERVI Certified Manufacturer: 1. Foundation Ian review and ins ection. DEVEDE ARTMENRVICES in the Roof, Walls or Floor. Building Engineer: p p Roof 25 psf (Snow) ............................. • ADA Accessibility to this structure shall be in conformance with local code including all BLAZER INDUSTRIES, Inc. Rock Shetler PO Box 489 � P.E. 2. An accessible route shall be provided to the building area as required in IBC section 1104. pathways, ramps and paths of travel for parking to building Blazer Industries, Inc. 3. Electrical connection to service. Wind ............................ 110 mph Exposure "C" (V) • Soil bearing requirement is 1500 psf, subGRADE Compaction at 90%. Aumsville, OR 97325 PO Box 489 4. On site electrical service grounding, electrode system and bonding. Contact: Jamie Holmes Aumsville, OR 97325 Floor 50 psf, Slab -On -Grade (typ.) • ( ) 5. Required arc flash labeling per NEC 110.16 """"""""""""""' p g p Building plumbing system Is based upon full flow existing water service. Loss of required flow Phone: (503) 749-1900 Phone: 503 749-1900 q g p 125 psf Storage & Pump room rate of 10 gpm or pressure below 35 psi may necessitate an intermediate well tank and check Fax: 503 749-3969 6. Available fault current field markings per NEC 110.24. valve in line. ( ) E-mail: rock@blazerind.com E-mail: james@blazerind.com 7. Plumbing connection to service. Seismic SITE CLASS D, SDS = 1.030, SDI = 0.558 Project close out documentation including, but not limited to applicable calculations energy """""""""""" • J 9, pp 9Y Project Owner: 8. Installation of heat tape, when required. compliance reports, fenestration NFRC rating certificates and 0 & M manuals is required to be CityOf Edmonds Washington delivered to the building owner within 90 days of their receipt of the certificate of occupancy. Designer / Dealer: 9. Water heater pressure relief valve and/or drain pan disposal terminates at building exterior or an Risk Category II 121 5th Ave. N. • Site installation details are noted on sheets A-4, A-5 and S-1 for structural connections, A-2 for PUBLIC RESTROOM COMPANY Edmonds, WA 98020 approved location. weatherization finish, P-1 for Plumbing connections and E-1 for electrical connections. SITE 2587 Business Parkway Contact: Henry Schroder 10. Permit and inspection via local AHJ for water heaters having a volume greater than 11.25 gallons Minimum allowable soil pressure 1,500 psf per Washington State Boiler and Unfired Pressure Vessel Laws Chapter 70.79 RCW and Chapter INSTALLATION PROCEDURE INCLUDES BUT NOT LIMITED TO: Service Hookups Minden, NV 89423 p g p p (Electrical & Plumbing connections), Closeup of roofing across mod line, material Installation Title: City's Project Manager 296-104 WAC, by others on site 10 days prior to placing the equipment into operation. City Of Edmonds of Modline trim interior and Exterior, Install backer rod and caulk mod line - walls, Install SL-1 Contact: Chad Kaufman Phone: 425 Phone: (888) 888-2060 ( ) 771-0220 x 1329 11. Insulation, vapor barriers, air barriers and draftstopping at marriage line installed on site. Building Department Self -leveling caulk (use on floor joint), Finish paint modline connection. Installation of Modline Fax: (425) 672-5750 -------- ---- ------------ & Capbeam Mod connections. Fax: (888) 888-1448 12. Site installed exterior lighting Work PLUMBING FOR PREFAB RESTROOM Mobile: (425) 361-8825 Address Email: Chad@publicrestroomcompany.com 13. Site completion or installation of siding, roofing, exterior/interior trim, floor covering and any 310 6TH AVE N Email: henry.schroder@edmondswa.gov electrical plumbing or mechanical crossover connections as the pertain to mod connections. owner ;-------------------------------------------- www. publicrestroomcompany.com p g y p CITY OF EDMONDS - CIVIC FIELD 14. Site installed utters & downspouts or roof drains as applicable. Approved Date; --------------------- Project Landscape Architect: g p pp si2ai2o22 15. Per WAC 296-15OF Section 0500 Item No. 1: The installation of interior equipment and appliances Building Official LB�o�6ac� M. Sh Walker Macy t associated with the modular unit shall be completed under permit and inspection with the local Permit Number ; WAs� T� 111 SW Oak ST. Suite 200 BLD2022-0736 o w� building department. Portland, OR 97204 Contact: Jason Bril SEPARATE BOILER THIS PLAN SET TO PRELI Title: Project Manager PERMIT REQUIRED - FROM L&I REMAIN ON SITE NOT FORC � SIo 0E,v N Phone: (503) 228 3122 NAL Email: jbril@walkermacy.com ■ COPYRIGHT 2021, BLAZER INDUSTRIES, INC. AND PUBLIC RESTROOM PROJECT NAME & LOCATION: SHEET TITLE: Approved for Const: Job No: 20076 COMPANY. THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF BLAZER • • PUBLIC ■■ INDUSTRIES, INC. AND PUBLIC RESTROOM COMPANY AND SHALL NOT RESTROOM Edmonds Civic Center Playfield TITLE SHEET File Copy: A,BE REPRODUCED, USED, OR DISCLOSED TO OTHERS EXCEPT AS COMPANY Drawn By: NJP ■■ Y!IDUSTRIES, INC. AUTHORIZED BY THE WRITTEN PERMISSION OF BLAZER INDUSTRIES BuildingBetter Places To Go. Edmonds WA /A, P.O. BOX 489 www.blazerind.com Ph: 888-882060 Fax: 888-888-1448 --- T�l DATE REV# REV15ION BY DATE REV# REV1510N BY ■■ 945 Olney St. ■ Aumsville, OR 97325-0489 OR PUBLIC RESTROOM COMPANY. Issue Date: 04-28-22 n,