DNS for reference STRANDED BY THE SEA APPROVED BLD2018-0867`yofE Af0 A -—
CITY OF EDMONDS
059ft
1111102PORMW
121 5TH AVENUE NORTH - EDMONDS, WA 98020
i o PHONE: (425) 771-0220 - FAX: (425) 771-0221
".189
Permit #: BLD20180867
Expiration Date: 07/20/20n9 `' Project Address: 176 SUNSET AVE S, EDMONDS,
Parcel No: 27032300104500�-V�
.��y. ..y.APPLICANT O.
STRANDED BY THE SEA LVL CONSTRUCTION LLC LVL CONSTRUCTION LLC
C/O CROSSING LLC SALISH C/O FRED ROBERTS C/O FRED ROBERTS
22833 BOTHELL EVERETT HWY STE 207 6830 NE BOTHELL WAY 4C222 6830 NE BOTHELL WAY 4C222
BOTHELL, WA 98201 KENMORE, WA 98028 KENMORE, WA 98028
(425)990-6200 (206)747-3733 (206)747-3733
LICENSE #: LVLCOCL838R2 EXP:12/22/2019
�Rill 1 R 1111s
ADD/INFILL WALLS - ADD/RELOCATE DOORS IN EXISTING TENANT SPA CE - NO CHANGE OF OCC - NO
PLUMBING/MECHANICAULIGHTING CHANGES PROPOSED
VALUATION: $1,000
PERMIT TYPE: Commercial
PERMIT GROUP: 71 - Tenant Improvement
GRADING: N CYDS: 0
TYPE OF CONSTRUCTION: VB
RETAINING WALL ROCKERY:
OCCUPANT GROUP: M
OCCUPANT LOAD:
FENCE: 0 X 0 FT.
CODE: 2015 IEBC/IBC/WSEC
OTHER: ------- OTHER DESC:
ZONE: BC
NUMBER OF STORIES: 1
VESTED DATE:
NUMBER OF DWELLING UNITS: 0
ILOT #:
BASEMENT: 0 1ST FLOOR: 1355 2ND FLOOR: 0
1
BASEMENT: 0 1ST FLOOR: 0 2ND FLOOR: 0
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
3RD FLOOR: 0 GARAGE: 0 DECK: 0 OTHER: 0
BEDROOMS:0 BATHROOMS:O
BEDROOMS:0 BATHROOMS:0
FRONTSETRACK SIDESETBACK
REQUIRED: PROPOSED: REQUIRED: PROPOSED: REQUIRED: PROPOSED:
HEIGHT ALLOWED:O PROPOSED:O REQUIRED: PROPOSED:
SETBACK NOTES: E-CDC 17.50.010.C.2. All existing and new uses in existing buildings are considered to comply with the parking requirements set forth
in this chapter of the code -
I AGREE TO COMPLY WITH CrrY AND STATE LAWS REGULATING CONSTRUCTION AND IN DOING THE WORK AUTHORIZED THEREBY, NO
PERSON WILL BE EMPLOYED IN VIOLATION OF THE LABOR CODE OF THE STATE OF WASHINGTON RELATING TO WORKMENS COMPENSATION
INSURANCE AND RCW 18:27.
THIS APPLICATION IS NOT A PERMIT UNTIL SIGNED BY THE BUILDING OFFICIAL OR HIS/HER DEPUTY AND ALL FEES ARE PAID.
,� Z <a %r / lu,�& L Zt 07 �! 2-Ole
I ur Print Name Date Released By V11Date
ATTENTION ,,
IT IS UNLAWFUL TO USE OR OCCUPY A BUILDING OR STRUCTURE UNTIL A FINAL INSPECTION HAS BEEN MADE AND APPROVAL OR A CERTIFICATE OF (D( J
OCCUPANCY HAS BEEN GRANTED. UBC109/ IBCI 10/ 1RC1 10. v,
FIRE APPLICANT ASSESSOR CI7y MQ
V\'
STATUS: ISSUED
BLD20180867
• Obtain Electrical Permit from State Department of Labor & Industries. 425-290-1309
• Final approval on a project or final occupancy approval must be granted by the Building Official prior to use or occupancy of
the building or structure. Checkthe job card for all required City inspections including final project approval and final
occupancy inspections.
• Any request for alternate design, modification, variance or other administrative deviation (hereinafter "variance") fi•om
adopted codes, ordinances or policies must be specifically requested in writing and be called out and identified. Processing
fees for such request shall be established by Council and shall be paid upon submittal and are non-refundable.
• Approval of any plat or plan containing provisions which do not comply with city code and for which avariance has not been
specifically identified, requested and considered by the appropriate city official in accordance with the appropriate provision
of city code or state law does not approve any items not to code specification.
• Sound/Noise originating from temporary construction sites as a result of construction activity are exempt fi•omthe noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30,120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly fi•omthe issuance for this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance nor limit in any way the City's ability to enforce any ordinance
provision.
• Request final Fire Department Inspection (425) 775-0215.
• Nothing in this permit approval process shall be interpreted as allowing orpernvtting the maintenance of any currently e)asting
illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the pemvt application,
regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or
condition may be the subject of a separate enforcement action.
THIS PERMIT AUTHORIZES ONLY THE WORK NOTED. THIS PERMIT COVERS WORK TO BE DONE ON PRNATE PROPERTY ONLY. ANY
CONSTRUCTION ON THE PUBLIC DOMAIN (CURBS, SIDEWALKS, DRIVEWAYS, MARQUEES, ETC.) WILL REQUIRE SEPARATE PERMISSION. PERMIT
TIME LIMIT: SEE ECDC 19.00.005(A)(6)
BUILDING
ENGINEERING (425) 771-0220 EXT. 1326
1. Go to: www.edmondswa.gov
Building Department Inspections
2. Then: Services
are now scheduled online. If you
FIRE (425) 775-7720
3. Then: Permits/Development
have difficulties, please call the
4. Then: Online Permit Info
Building Department front desk for
PUBLIC WORKS (425) 771-0235
5: If you don't have one already, create a
assistance during office hours.
login (upper right hand corner)
(425) 771-0220
RECYCLING (425) 275-4801
6: Schedule your inspection
When calling for an inspection please leave the following information: Permit Number, Job Site Address, Type of Inspection
being requested, Contact Name and Phone Number, Date Preferred, and whether you prefer morning or afternoon.
• B-Preconstruction meeting
• B-Framing-Accessibility Provisions
• B-Building Final
• F-Fire Final
1,7 90
BUILDING PERMIT
APPLICATION
Development Services
Building Division
121 5th Ave N / Edmonds, WA 98020
425.771.0220
For handouts, submittal requirements, permit status and inspection
scheduling information go to: http://www.edmondswa.gov/
JOB SITE INFORMATION/LOCATION: (Where the work is taking place)
Job Site Address: 176 Sunset Ave
Parcel: 27032300104500
Lot /Unit/Suite #: n / a SuSubdivision: n�/j�a ,, n
PROPERTY OWNER: '�h�`'.' ►J� W1 rUi' COILO U
Name. Salish Crossing L
Mailing Address: Pacific Asset Advisors, Inc.
14205 SE 36th St Ste 215
City/state/zip: _ Bellevue, WA 98006
Phone#: 425-990-6200
Email: n/a
OWNER INSTALLATION: "If yes, read and sign*
Will work be performed by the property owner? ❑ yes NI. No
I own, reside in, or will reside in the completed structure.
This installation is being made on property that I own which is
not intended for sale, lease, rent, or exchange according to
RCW 18.27.090.
Owner Signature:
APPLICANT / CONTACT INFORMATION:
Name of Applicant: LVL Construction LLC
Mailing Address: 152 3rd Ave S Ste 107
City/State/Zip: Edmonds WA 98202
Phone#: 206-747-3733
E-mail: f`fred@LVLConstuction.com
GENERAL CONT ACTOR: (if different from appliccan`t)�r-- ` �
General Contr ctor:�V
Mailing Addre:
City/State/Zip:
Phone #:
E-mail:
WA STATE CONTRACTOR L & I # (CCB) & EXPIRATION DATE:
LVLCOCL838R2 exp 12/22/2019
CITY OF EDMONDS BUSINESS LICENSE #: NR— 0 2 5 7 8 2
Office Use Only
Permit #:
(Provide
TYPE OF PERMIT Details
❑ Accessory Structure/ ❑ Addition
Detached Garage
❑ Demolition ❑ Mechanical
❑ New Single Family / Duplex ❑ Plumbing
❑ Fire Sprinkler ❑ Remodel
❑ New Commercial/ Mixed Use ❑ Re -Roof
❑ Signs ❑ Tank
IN Tenant Improvement ❑ Other
Remodel Permit fees are based on:
The value of the work performed. Indicate the value (rounded to
the nearest dollar) of all equipment, materials, labor, overhead,
and the profit for the work indicated on this application.
Valuation: $1, 0 0 0. 0 0
PROPOSED NEW SQUARE FOOTAGE FOR THIS APPLICATION
Bas nt sq ft: Finished ❑ Unfinished ❑
1st Floor, sq ft:
2nd Floor, sq ft:
Garage/Carport:, sq ft:
Deck/Covered Porch/Patio:
Other sq ft:
PROJECTDESCRIPTION
Add partition wall (15' long x 10'
tall) to connect Northern wall of
bathroom to Northern wall of unit to
create a 91 sq ft storage space with a
36" access door. Also, move interior
bathroom door to existing Eastern
partition wall of bathroom and frame in
space on Northern bathroom wall.
I certify that the information I have provided on this form/application is true,
correct and complete, and that I am the property owner or duly authorized
agent of the property owner to submit a permit application to the City of
Edmonds.
Print Name: Fred_504erts, Manager
Signature: Date ?� /8
C* of Edmonds _ h
epartmen
ity
aft n
t -
APPROV"
All changes in plans and field
modifications shall be approved by
the local jurisdiction. The design
professional shall prepare drawings as
required for approval.
IBC 107.4
Nothing in this permit approval
process shall be interpreted as
allowing or permitting the
maintenance of any currently existing
illegal, nonconforming, or
unpermitted building, structure, or
site condition which is outside the
scope of the permit application,
regardless of whether such building,
structure, or condition is shown on the
site plan or drawing. Such building,
structure, or condition may be the
subject of a separate enforcement
action.
TRO IA
D B PPJNI
GROUP - AA
LOAD Z 7,,
Fsot
btain. Electrical Permit from
�itc Labor & Industries
AGG1 ,..W,>, ,o- .erwu,�uwra�wn
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
a
CITY OF EDMONDS
BUILDING DEPARTMENT
WORK
=I -
ADDRESS
OWNER
APPROVED DATE: -7- %1-16
BLDG. OFFICIAL:Z 4- Vvy
PERMIT NUMBER
CITY COPY
G
PACIFIC ASSET -1
ADVISORS, INC. '
Stranded by the Sea, Inc.
176 Sunset Ave, Edmonds, WA 98020
Tenant Improvement Plans
SUITE
190-A
TENANT
Scratch Distillery
SQ. FT.
3,508
190-B&D
190 Sunset Restaurant
3,868
190-C
Brigid's Bottle Shop
1,951
190E
Cascadia Art Museum
11,029
1881"xc,VACANT^
,5;80d
186
Hunni Water
1,892
184
First Financial NW Bank
2,529
SALISH CROSSING
190 Sunset Avenue South, Edmonds, WA 98020
SUITE
182
TENANT
Thai by Day
SO. FT.
1,990
178
Eviva Wood Fired Pizza
1,335
06
Stranded by the Sea
1;355
174
Spud's Fish & Chips
1,892
172
The Workshop
2,969
Bldg. C
Top Pot Donuts
1,525
RECEIVED
JUN 2 5 20 ►0
L)EVkt.Grivirsv I StHVIGES CTR.
CITY OF EDMONDS
Stranded by the Sea, Inc.
176 Sunset Ave, Edmonds, WA 98020
Tenant Improvement Plans
25'-6"
101-01,
r , atliroo D� o, _
O 1pma•60sq .gw
q 60" MIN DIA 6' 0" 91 sq ft
15'2"x6'0"
SL`� Stv4� 3
bo Fox M/kmsu VLXt 06
Fire
Extinguished
6'-2'
25' 6" x 48' 8"
Retail Floor Space
Fire 1240 sq ft
Extinguisher
HVAC
5'-101/2" controller
S '/
M /v:d'
e,
.pro, ''.•.
rr01r0. /�
6 .4,, r AiDA
--I To
.Sign
(exterior lighted sign)
'ZZ
I OOY 4. Z
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
RECEIVED
.SUN 25 2018
DEVELOPiAENT SERVICES CTR.
CITY OF EDMONDS
ICC A117.1-2009
Chapter 4. Accessible Routes
than 34 inches (865 mm) above the floor. Projections
into the clear opening width between 34 inches (865
mm) and 80 inches (2030 mm) above the floor shall
not exceed 4 inches (100 mm).
EXCEPTIONS:
1. Door closers and door stops shall be permit-
ted to be 78 inches (1980 mm) minimum
above the floor.
with Section 404.2.3 and shall include the full clear
opening width of the doorway. Required door
maneuvering clearances shall not include knee
and toe clearance.
404.2.3.1 Floor Surface. Floor surface within the
maneuvering clearances shall have a slope not
steeper than 1:48 and shall comply with Section
302.
2. In alterations, a projection of 5/e inch (16 404.2.3.2 Swinging Doors. Swinging doors shall
mm) maximum into the required clear open- have maneuvering clearances complying with
ing width shall be permitted for the latch side Table 404.2.3.2.
stop. 404.2.3.3 Sliding and Folding Doors. Sliding
404.2.3 Maneuvering Clearances. Minimum doors and folding doors shall have maneuvering
maneuvering clearances at doors shall comply clearances complying with Table 404.2.3.3.
TABLE 404.2.3.2—MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS
TYPE OF USE
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS
Approach Direction
Door Side
Perpendicular to Doorway
Parallel to Doorway
(beyond latch unless noted)
From front
Pull
60 inches (1525 mm)
18 inches (455 mm)
From front
Push
48 inches (1220 mm)
0 inches (0 mm)
From hinge side
Pull
60 inches (1525 mm)
36 inches (915 mm)
From hinge side
Pull
54 inches (1370 mm)
42 inches (1065 mm)
From hinge side
Push
42 inches (1065 mm)'
22 inches (560 mm)
From latch side
Pull
48 inches (1220 mm
24 inches (610 mm)
From latch side
Push
42 inches (1065 MM)2
24 inches (610 mm)
'Add 6 inches (150 mm) if closer and latch provided.
2Add 6 inches (150 mm) if closer provided.
3Add 12 inches (305 mm) beyond latch if closer and latch provided.
4Beyond hinge side.
TABLE 404.2.3.3—MANEUVERING CLEARANCES AT SLIDING AND FOLDING DOORS
Approach Direction
MINIMUM MANEUVERING CLEARANCES
Perpendicular to doorway
Parallel to Doorway
(beyond stop or latch side unless noted)
From front
48 inches (1220 mm)
0 inches (0 mm)
From nonlatch side
42 inches (1065 mm)
22 inches (560 mm)'
From latch side
42 inches (1065 mm)
24 inches (610 mm)
'Beyond pocket or hinge side.
(a) Front Approach
F---------- I
I4>
I
I I
I I CLO
I I NO
1 22 min I v
560 I
------
(b) Pocket or Hinge Approach
- - - - - - - - - -
I �I
LO I I
E w 1 24 min
O
j 610 I
(c) Stop or Latch Approach
FIG. 404.2.3.3
MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS
Chapter 4. Accessible Routes
ICC A117.1-2009
r----------,
v
I I 18 min
E N I I 455
t
1 I
i I
(a) Front Approach, Pull Side
12 min' 1 I I E Nr
305
I I t
'If both closer and latch are provided
(b) Front Approach, Push Side
r-------------7
I
1
I
1
to
I E N
I 36 m
915
I
tl 42 min 1
tl 1065 t
I I
I
(c) Hinge Approach, Pull Side
(d) Hinge Approach, Pull Side
12 min'
305
r — — — — — —
r-----------
I
4n--n--1 1 I
d I I
l I tl 22 min
I 1 560
E I 1 I
1 1 I
c I 24 min
o
_ I 610
v t 1
I I
'54 min (1370) if closer is provided
' If both closer and latch are provided
48 min (1220) if both closer and latch provided
(e) Hinge Approach, Push Side
(f) Latch Approach, Pull Side
r� -----------�
II
I I
24 min 1 'E LD
610 a
! i
I
`48 min(1220)
if closer is provided
(g) Latch Approach, Push Side
FIG. 404.2.3.2
MANEUVERING CLEARANCE AT MANUAL SWINGING DOORS
18
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
Existing bathroom
fixtures to remain,
including grab bar
REF Sg-66r 5-
�qg jZ6Q ` /966
PA ASS
r
M
m
m
G�
oC
N
t2
jTi)
� o
A
Interior door for bathroom
to be relocated to existing
Easternly partition wall
Stranded by the Sea, Inc.
176 Sunset Ave, Edmonds, WA 98020
Tenant Improvement Plans
10'-0"
Bathroom
60 sq ft
10"D, " x 6' 0"
60" MIN DIA
3 ,toll 1.
� sc�'"
-6 �E7 I
36in.
n4)
Existing door to be removed and space
filled in partition wall between
bathroom and office
M A TZ*r 6--A ►s-"^,6
15'-2"
91sgft
15'2"x6'Oil
Scale: %" : 1'
M
Interior partition wall to(��`'�
be constructed -- 'i�,Scuss '9>of�"'
eLAart AV-At4,u6%'t--
New interior door 70P 6M"-406 - W`t
to be installed CaAS'rR-jt'V&A L'Prd-
�N�
0 ft. 2 ft. 4.8 in. 4 ft. 8 ft.
ICC A117.1-2009
Chapter 6. Plumbing Elements and Facilities
604.3 Clearance.
Other fixtures not allowed
...;.k;., �k;, ., ,
60 min
1525
FIG. 604.3
SIZE OF CLEARANCE FOR WATER CLOSET
604.3.1 Clearance width. Clearance around a water
closet shall be 60 inches (1525 mm) minimum in
width, measured perpendicular from the sidewall.
604.3.2 Clearance Depth. Clearance around the
water closet shall be 56 inches (1420 mm) mini-
mum in depth, measured perpendicular from the
rear wall.
604.3.3 Clearance Overlap. The required clear-
ance around the water closet shall be permitted to
overlap the water closet, associated grab bars,
paper dispensers, sanitary napkin receptacles,
coat hooks, shelves, accessible routes, clear floor
space at other fixtures and the turning space. No
other fixtures or obstructions shall be within the
required water closet clearance.
604.4 Height. The height of water closet seats shall be
17 inches (430 mm) minimum and 19 inches (485 mm)
maximum above the floor, measured to the top of the
seat. Seats shall not be sprung to return to a lifted posi-
tion.
EXCEPTION: A water closet in a toilet room for a sin-
gle occupant, accessed only through a private office
and not for common use or public use, shall not be
required to comply with Section 604.4.
1jC 604.5 Grab Bars. Grab bars for water closets shall
comply with Section 609 and shall be provided in accor-
dance with Sections 604.5.1 and 604.5.2. Grab bars
shall be provided on the rear wall and on the side wall
closest to the water closet.
EXCEPTIONS:
1. Grab bars are not required to be installed in a
toilet room for a single occupant, accessed
only through a private office and not for com-
mon use or public use, provided reinforcement
has been installed in walls and located so as to
permit the installation of grab bars complying
with Section 604.5.
2. In detention or correction facilities, grab bars
are not required to be installed in housing or
holding cells or rooms that are specially
designed without protrusions for purposes of
suicide prevention.
Seat height
17 - 19
430 485
Note: For children's dimensions see Fig. 604.11.4
FIG. 604.4
WATER CLOSET SEAT HEIGHT
604.5.1 Fixed Side Wall Grab Bars. Fixed side -wall
grab bars shall be 42 inches (1065 mm) minimum in
length, located 12 inches (305 mm) maximum from
the rear wall and extending 54 inches (1370 mm)
minimum from the rear wall. In addition, a vertical
grab bar 18 inches (455 mm) minimum in length shall
be mounted with the bottom of the bar located 39
inches (990 mm) minimum and 41 inches (1040 mm)
39--41
990 - 1040
54 min 0
12 max 137fl �
305
Section 609.4
_ c
d
M
6)
I I
I
c
M
M
O
0
M Cr
Q
Note: For children's dimensions see Fig. 609.4.2
FIG. 604.5.1
SIDE WALL GRAB BAR FOR WATER CLOSET
S/°7
Chapter 6. Plumbing Elements and Facilities
ICC A117.1-2009
101
0*
maximum above the floor, and with the center line of
the bar located 39 inches (990 mm) minimum and 41
inches (1040 mm) maximum from the rear wall.
EXCEPTION: The vertical grab bar at water clos-
ets primarily for children's use shall comply with
Section 609.4.2.
604.5.2 Rear Wall Grab Bars. The rear wall grab bar
shall be 36 inches (915 mm) minimum in length, and
extend from the centerline of the water closet 12
inches (305 mm) minimum on the side closest to the
wall, and 24 inches (610 mm) minimum on the trans-
fer side.
EXCEPTIONS:
1. The rear grab bar shall be permitted to be
24 inches (610 mm) minimum in length, cen-
tered on the water closet, where wall space
does not permit a grab bar 36 inches (915
mm) minimum in length due to the location
of a recessed fixture adjacent to the water
closet.
2. Where an administrative authority requires
flush controls for flush valves to be located
in a position that conflicts with the location of
the rear grab bar, that grab bar shall be per-
mitted to be split or shifted to the open side
of the toilet area.
36 min
915
12 min
oe 24 min
305
610
lo
4
c
rn
I�
0) COO
M
fh
o
O .
N
0
rn
Note: For children's dimensions see Fig. 609.4.2
FIG. 604.5.2
REAR WALL GRAB BAR FOR WATER CLOSET
011
604.6 Flush Controls. Flush controls shall be hand
operated or automatic. Hand operated flush controls
shall comply with Section 309. Flush controls shall be
located on the open side of the water closet.
EXCEPTION: In ambulatory accessible compart-
ments complying with Section 604.10, flush controls
shall be permitted to be located on either side of the
water closet.
604.7 Dispensers. Toilet paper dispensers shall com-
ply with Section 309.4. Where the dispenser is located
above the grab bar, the outlet of the dispenser shall be
located within an area 24 inches (610 mm) minimum
and 36 inches (915 mm) maximum from the rear wall.
Where the dispenser is located below the grab bar, the
outlet of the dispenser shall be located within an area
24 inches (610 mm) minimum and 42 inches (1065 mm)
maximum from the rear wall. The outlet of the dispenser
shall be located 18 inches (455 mm) minimum and 48
inches (1220 mm) maximum above the floor. Dispens-
ers shall comply with Section 609.3. Dispensers shall
not be of a type that control delivery, or do not allow
continuous paper flow.
604.8 Coat Hooks and Shelves. Coat hooks provided
within toilet compartments shall be 48 inches (1220
mm) maximum above the floor. Shelves shall be 40
inches (1015 mm) minimum and 48 inches (1220 mm)
maximum above the floor.
604.9 Wheelchair Accessible Compartments
604.9.1 General. Wheelchair accessible compart-
ments shall comply with Section 604.9.
604.9.2 Size. Toilet compartments shall comply with
Section 604.9.2.1 or 604.9.2.2 as applicable.
604.9.2.1 Minimum area. The minimum area of a
wheelchair accessible compartment shall be 60
inches (1525 mm) minimum in width measured
perpendicular to the side wall, and 56 inches
(1420 mm) minimum in depth for wall hung water
closets, and 59 inches (1500 mm) minimum in
depth for floor mounted water closets measured
perpendicular to the rear wall.
604.9.2.2 Compartment for children's use. The
minimum area of a wheelchair accessible com-
partment primarily for children's use shall be 60
inches (1525 mm) minimum in width measured
perpendicular to the side wall, and 59 inches
(1500 mm) minimum in depth for wall hung and
floor mounted water closets measured perpendic-
ular to the rear wall.
604.9.3 Doors. Toilet compartment doors, including
door hardware, shall comply with Section 404,
except if the approach is to the latch side of the com-
partment door clearance between the door side of
the stall and any obstruction shall be 42 inches (1065
mm) minimum. The door shall be self -closing. A door
pull complying with Section 404.2.6 shall be placed
on both sides of the door near the latch. Toilet com-
partment doors shall not swing into the required mini-
mum area of the compartment.
604.9.3.1 Door Opening Location. The farthest
edge of toilet compartment door opening shall be
located in the front wall or partition or in the side
wall or partition as required by Table 604.9.3.1.
604.9.4 Approach. Wheelchair accessible compart-
ments shall be arranged for left-hand or right-hand
approach to the water closet.
48
7
rr
Stranded by the Sea, Inc.
176 Sunset Ave, Edmonds, WA 98020
Tenant Improvement Plans
Elevation
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
ipty space to be filled in
partition wall along
irthern side of bathroom
er existing door removed
4 A-Tkj- 6ac/c-1 7,j 4
,,,off t,E _,C,ES,sr� �rr� AlOM
vA wpf-jl
Oft. 2ft.4.8in. Oft. 8ft.
Scale: %" : V
M�
N
CID
1�
Stranded by the Sea, Inc.
176 Sunset Ave, Edmonds, WA 98020
Tenant Improvement Plans
Elevation
A*)
Interior partition wall to
be constructed
Open space
10'-0" 15'-6"
..................... .........................._..............._........_...................................... .......... ..... ...................................
36in.
36in.
MIN
6 MIN � j f/.: // � / �/
✓ ;>:� � �,�.`�.
,
X , /.
'
Interior door for bathroom to
be relocated to existing
Easternly partition wall
New interior door
to be installed
71 ►s(.wss T�Oij"�M
-Tvp 0�- WAtw &u�
Vj Art& CA..1 STi Q a7
w q'4- ?3u4.D/�J4
I r►sP6404 ?/-► 04
'70 ��h1N►r►�+
W D[_
oft. 2 ft. 4.8 in. 4 ft. 8 ft.
Scale: %" : 1'
Stranded by the Sea, Inc.
176 Sunset Ave, Edmonds, WA 98020 /'4ZZ4-1.
Tenant Improvement Plans
Occupancy G: M
Load: 22
25-6 Per IBC Table 1004.1.2
'i
I
L3'-0 10'-0" 15'
'',Bathroom _
��w.. 1 ',60 sq ft
Q 60" MIN D�IA ':x 6' o" Storage
/ \\ 152 sq ft
15'2"x10'0"
452 Bracing
See Sheet 3 for Fire a0
Maneuvering ! Extinguishers
Clearance 6'-2'
CCd
3 N ar
approx
25' 6" x 45' 0"
Fire
Retail Floor Space
a pOp to Q W_
Extinguisheq
approx 1150 sq ft
a�
y U y p
5'-101/2"HVAC
ntroller
o O U
V Q.)
•> 0
'+••' a V
36" Max Height
N
o b > �q a�i
for ADA
o.Z
U
0O
L'%.
Ir o d O
O O U cc
F G O tad
To
,Sign
ti
/
EXIT Sign
(exterior lighted sign)
on. ZfLC81, Oft. E e,/ 3 KC)' M
C E717 C(0)EY JUL 31 2018
BUILDING DEPARTMENT
CITY OF EDMONDS
REVISED PLAIN APPROVED
CITY OF EDMONDS ILDING DIVISION
PLANS EXA119NER
DATE `, ' (v
i
Existing bathroom
fixtures to remain,
including grab bar
See Sheet 5 for
Required Grab Bars
Interior door for bathroom
to be relocated to existing
Easternly partition wall
See Sheet 3 for
Maneuvering Clearance
48" perpendicular to doorway
12" beyond latch
Stranded by the Sea, Inc.
176 Sunset Ave, Edmonds, WA 98020
Tenant Improvement Plans
Existing door to be removed and space
filled in partition wall between
bathroom and storage.
Match existing
ain
10'-0" El ctrical
..._.......................................................... _ .
J Panel
J - Bathroom
60 sq ft
10'\,0" x 6' 0"
60" MIN DIA
36in.
�:aneuve`rin
/Cleafa+n;c-lip
�48;;�perper%dciilar,.•';
12;beyond;latch `
''` 36in.
New interior door
to be installed
15'-2"
.....................................................................................................
Storage
152 sq ft
15'2"x10'0"
452 Bracing
T
Interior partition walls to be constructed
Discuss bottom plate attachment - Top of
wall bracing wall construction with
Building Inspector prior to beginning work
0 ft. 2 ft. 4.8 in. 4 ft. 8 ft.
Scale: %" : V
SOON
CITY COPY . JUL 31 2018
':41JILDING DEPARTMENT