Loading...
APPROVED BLD-BLD2022-0528+Architectural_Plan+4.27.2022_4.06.48_PM+28319901 of 4 21501 y M P ic Ave, (SPECIAL INSPECTIONS REQUIRED x Installation of Foundation Brackets I x Grading/soils . i ! x Installation of Helical Piles I x Installation of Driven Piles • ■ I I ■ Edmonds Residence APPROVED PLANS MUST BE ON JOB SITE City of Edmonds Building Department APPROVED Plans ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE S220112-IXR PROJECT INFORMATION CLIENT MANSFIELD LINDA A & BRUCE TAMI TAYLOR 215 OLYMPIC AVE EDMONDS, WA 98020 PROJECT ADDRESS 215 OLYMPIC AVE EDMONDS, WA 98020 STRUCTURAL ENGINEER L120 ENGINEERING & DESIGN 1315091STPLNE KIRKLAND, WA 98034 CONTACT: MANS THURFJELL, PE PHONE: (425)-636-3313 EMAIL: MTHURFJELL@Ll20ENGINEERING.COM CODES ENGINEERED PER: 2018 (IRC) INTERNATIONAL RESIDENTIAL CODE 2018 (IBC) INTERNATIONAL BUILDING CODE SHEET INDEX COVER SHEET .... S-0 aI:IN LaIII :Z1we] 2 110121:7_100IQI14�2i1 SITE & FOUNDATION PLAN .... S-2 FOUNDATION DETAILS .... SD-1.1 City Of Edmonds Building Department Work FOUNDATION STABILIZATION Address 215 OLYMPIC AVE ------------------------------------------ Owner HALL 9ta--for Approved Date 06-17-2022 Building Official lcew� gi'oox lQ lal Permit NumbE r BLD2022-0528 + f ■ ■ • f # #t+, # f�• � [rye • r � kF W Q J z o W _ > z ,R > z w zwz Z w O O z J \ REVISIONS 0 DESCRIPTION DATE BY PROJECT NAME 215 OLYMPIC AVE, EDMONDS, WA 98020 PROJECT NUMBER S220112-1XR DRAWN ui - NJ CHECKED BY M RT SHEET DATE 1 /15/22 SL' RECEI ED Apr 28 2 22 CITY OF EDMC DEVELOPMENT SE NDS RVICES DEPARTMEr T z 0 o 1 �c V) w V > w O w U w 2 of 4 GENERAL STRUCTURAL NOTES DESIGN CRITERIA CODE: 2018 IBC/IRC & AMENDMENTS AS ADOPTED BY THE REVIEWING AGENCY/COUNTY. ROOF........................................25 PSF SNOW (GROUND) FLOORS RESIDENTIAL .....................40 PSF BALCONY/DECK................60 PSF GENERAL CONDITIONS 1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES HE MAY FIND BEFORE PROCEEDING WITH THE WORK. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING WORK. THE ARCHITECT/ENGINEER SHALL IMMEDIATELY BE NOTIFIED IN WRITING OF ANY DISCREPANCIES. 3. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY WORK SO INVOLVED. 4. IN CASE OF CONFLICT, NOTES AND DETAILS OF THESE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE "GENERAL NOTES" AND/OR "STANDARD DETAILS". 5. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL BE THE SAME AS FOR SIMILAR WORK. 6. WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE DRAWINGS. 7. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE DISTRESS TO THE STRUCTURE. 8. THE CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND HE SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. 9. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE, AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER ANY PORTION OF THE WORK. 10. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE THE NOTES, DRAWINGS, AND/OR SPECIFICATIONS DIFFER, THE MORE STRINGENT REQUIREMENT SHALL APPLY. 11. REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES OR THE STRUCTURAL DRAWINGS. 12. NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. 13. DISCREPANCIES FOUND BETWEEN STRUCTURAL DRAWINGS AND OTHER DOCUMENTS ARE TO BE NOTED IN WRITING TO THE ENGINEER PRIOR TO CONSTRUCTION. 14. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS, METHODS, AND WORKMANSHIP ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY IN CONFORMANCE TO THE PROVISIONS OF THE "INTERNATIONAL BUILDING CODE" (IBC), AND STANDARDS REFERENCED THEREIN. 15. STRUCTURAL STABILITY OF ALL NEW AND EXISTING STRUCTURES DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THIS INCLUDES EXCAVATIONS, COLUMNS, EQUIPMENT LOADS, MATERIAL LOADS, AND OTHERS. OBSERVATIONS BY THE ENGINEER -OF -RECORD DO NOT INCLUDE INSPECTIONS OF TEMPORARY LOADING AND STABILITY DURING CONSTRUCTION. 16. PILE AND SOILS PARAMETERS PER GEOTECHNICAL REPORT DATED MARCH 2, 2022 BY COBALT GEOSCIENCES. ESTIMATED DEPTH TO END BEARING REFUSAL ............. 10'-0" to 20'-0" CONCRETE ANCHORS 1. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG TIE, HILTI, OR EQUIVALENT. SPECIAL INSPECTIONS REQUIRED. STRUCTURAL AND MISC. STEEL 1. REFERENCE STANDARDS: DESIGN, FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". 2. MATERIALS: BOLTS - ASTM A307, UNLESS OTHERWISE NOTED WF BEAMS - ASTM A572-50 (Fy = 50,000 PSI) HSS ROUND COLUMNS - ASTM A500 Gr. B (Fy = 42,000 PSI) HSS RECTANGULAR COLUMNS - ASTM A500 Gr. B (Fy = 46,000 PSI) ALL OTHER STEEL - ASTM A36 (Fy = 36,000 PSI) STRUCTURAL STEEL WELDING 1. CONFORM TO THE AWS CODES D1.1 AND D1.3., AND USE ONLY CERTIFIED WELDERS. WELDS NOT SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY E70 ELECTRODES. Al TFRNIATFC- 1. ALTERNATE ASSEMBLIES AND MATERIALS WILL BE CONSIDERED FOR REVIEW. ENGINEER MAY REQUEST PAYMENT FOR REVIEW; CONTRACTOR WILL BEAR BURDEN FOR ADDITIONAL PAYMENT AT NO ADDITIONAL COST TO OWNER. JOBSITE SAFETY: 1. THE ENGINEER AND/OR ARCHITECT HAVE NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN AND/OR CONSTRUCTION REVIEW SERVICES RELATED TO THE CONTRACTOR'S SAFETY PRECAUTIONS OR TO MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES FOR THE CONTRACTOR TO PERFORM HIS WORK. THE UNDERTAKING OF PERIODIC SITE VISITS BY THE ENGINEER AND/OR ARCHITECT SHALL NOT BE CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION NOR MAKE HIM RESPONSIBLE FOR PROVIDING A SAFE PLACE FOR THE PERFORMANCE OF WORK BY THE CONTRACTOR, SUBCONTRACTORS, SUPPLIERS OR THEIR EMPLOYEES, OR FOR ACCESS, VISITS, USE, WORK, TRAVEL, OR OCCUPANCY BY ANY PERSON. HELICAL PILES 1. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING CODE (IBC). 2. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY IDEAL MANUFACTURING, INC., AND SHALL BE IN ACCORDANCE WITH ESR-3750. 3. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH ESR-3750. 4. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER (EAA) COATINGS (AC228). 5. ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER AC358 SECTION 3.9. 6. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. 7. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED. 8. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF INCLINATION OF +/- 1 DEGREE FROM VERTICAL PER SECTION 4.2.1 OF ESR-3750. 9. MONITOR AND RECORD DEPTH OF PILE PENETRATION. PROVIDE TORQUE MONITORING DEVICE AS PART OF THE INSTALLING UNIT. MONITOR AND RECORD TORQUE APPLIED DURING THE INSTALLATION OF EACH PILE AT SPECIFIC DEPTHS. 10. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM VALUE TORQUE REQUIRED TO Q PROVIDE THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY. 11. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). 12. REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE FULLY ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION. 13. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH TO DEVELOP THE TORQUE REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES. 14. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION. 15. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2O15 AND 2012 IBC SECTION 1705.9 MUST BE PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION BRACKETS. ITEMS TO BE RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST INCLUDE THE FOLLOWING: A. PRODUCT MANUFACTURER B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS, EXTENSIONS, BRACKETS, BOLTS, THREADED RODS, NUTS, WASHERS, AND TORQUES AS SPECIFIED IN THIS REPORT AND THE CONSTRUCTION DOCUMENTS D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT, INSTALLATION EQUIPMENT USED, AND THE IDEAL FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS E. ANTICIPATED AND ACTUAL PILING DEPTH F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION G. INCLINATION AND POSITION OF PILES, TOP OF PILE EXTENSION IN FULL CONTACT WITH BRACKET, TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS ARE INSTALLED BY AN APPROVED IDEAL FOUNDATION SYSTEMS INSTALLER. 16. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED. HELICAL PILE PROOF TESTING THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2015 SEATTLE BUILDING CODE (SBC). THE MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD. CONCENTRIC DRIVEN PILES 1. "CONCENTRIC" OR DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2018 INTERNATIONAL BUILDING CODE (IBC). 2. IT IS RECOGNIZED THAT THE SEATTLE BUILDING CODE (SBC) REQUIRES 8 INCH MINIMUM DIAMETER PIPE FOR PIPE PILE INSTALLATION. THE APPROPRIATE ANALYSIS/EVALUATION AND TESTING REQUIREMENTS IN ACCORDANCE WITH SEATTLE DEPARTMENT OF CONSTRUCTION & INSPECTIONS (SDCI) DIRECTOR'S RULE 10-2009 ARE PROVIDED TO ALLOW FOR USE OF PILES LESS THAN 8 INCHES IN DIAMETER AS REQUIRED BY SECTION 104.5 OF THE SBC. 3. DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED BY STABIL-LOC SYSTEMS, LLC, AND SHALL BE IN ACCORDANCE WITH ESR-4121. 4. ALL MATERIAL PROPERTIES OF DRIVEN PILE COMPONENTS SHALL COMPLY WITH ESR-4121. 5. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER (EAA) COATINGS (AC228). 6. ALL PILE COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER AC358 SECTION 3.9. 7. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. 8. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED. 9. DRIVEN PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF INCLINATION OF 1 DEGREE FROM VERTICAL PER SECTION 5.7 OF ESR-4121. 10. DRIVEN PILES SHALL BE INSTALLED TO THE MINIMUM FORCE REQUIRED TO PROVIDE THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). THE MAXIMUM INSTALLATION FORCE SHALL NOT EXCEED THE ALLOWABLE CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE ASSEMBLY. 11. ALL BRACKETS AND PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). 12. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION. 13. SPECIAL INSPECTION IN ACCORDANCE WITH IBC SECTION 1705.7 IS REQUIRED FOR INSTALLATION OF THE STABIL-LOC FOUNDATION PIERING SYSTEM. A GEOTECHNICAL SPECIAL INSPECTOR MUST VERIFY AND RECORD THE FOLLOWING: A. VERIFICATION OF MANUFACTURER PRODUCT MODEL NUMBERS B. TYPES, CONFIGURATIONS, AND IDENTIFICATIONS OF HYDRAULICALLY DRIVEN STEEL PIER SEGMENT AND ADJUSTABLE HEAD ASSEMBLY AS SPECIFIED IN ESR-4121 AND THE CONSTRUCTION DOCUMENTS. C. INSTALLATION PROCEDURES, ANTICIPATED AND ACTUAL PILING DEPTH D. TIP ELEVATIONS, THE INSTALLATION PRESSURE AND FINAL DEPTH OF THE DRIVEN FOUNDATION SYSTEM E. INCLINATION AND POSITION/LOCATION OF HYDRAULICALLY DRIVEN PIER SEGMENTS F. COMPLIANCE OF THE INSTALLATION WITH THE APPROVED CONSTRUCTION DOCUMENTS AND THIS EVALUATION REPORT. 14. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED. DRIVEN PILE PROOF TESTING THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2015 SEATTLE BUILDING CODE (SBC). THE MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD. SPECIAL INSPECTIONS SCHEDULE SPECIAL INSPECTIONS TABLES PER THE 2018 IBC. ALL ITEMS NON -APPLICABLE ITEMS HAVE BEEN MARKED WITH A "". ITEMS REQUIRING SPECIAL INSPECTION HAVE BEEN MARKED WITH AN "X". TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION CONTINUOUS PERIODIC SPECIAL REFERENCED IBC TYPE SPECIAL INSPECTION INSPECTION STANDARD s REFERENCE 1. Inspect reinforcement. including prestressing ACI 318 Ch. 20. 25.2, tendons. and verify placement. 25.3. 26.5.1-26.5.3 1908.4 2. Reinforcing bar welding: a. Verify weldability of reinforcing bars other than ASTM A 706: AWS D1.4 b. Inspect single -pass fillet welds. maximum ACI 318: 26.5.4 �! -and - 1& c. Inspect all other welds. 3. Inspect anchors cast in concrete. - - ACI 318: 17.8.2 4-Inspect anchors anchors post -installed in hardened concrete members- a- Adhesive anchors installed in horizontally or upwardly inclined orientations to resist - - ACI 318: 17.8.2.4 - sustained tension loads. b. Mechanical anchors and adhesive anchors not defined in 4.a 5. Verify use of required design mix_ - - ACI 318: Ch. 19. 1904.1. 1904.2. 26.4.3. 26.4.4 1908.2. 1908.3 6. Prior to concrete placement. fabricate specimens ASTM C 172 for strength tests. perform slump and air - - ASTM C 31 1908.10 content tests, and determine the temperature of ACI 318: 26.4.5. 26.12 the concrete. 7. Inspect concrete and shotcrete placement for ACI 318: 26.4.5 1908.6. 1908.7. proper application techniques- 1908.8 8-Verify maintenance of specified curing - - ACI 318: 26.4.7-26.4.9 1908.9 temperature and techniques- 9- Inspect prestressed concrete for- a- Application of prestressing forces, and - - ACI 318: 26.9.2.1 - b. Groutingof bonded restressm tendons. - - ACI 318: 26.9.2.3 10. Inspect erection of precast concrete members. - - ACI 318: Ch. 26.8 - 11. Verify in -situ concrete strength. prior to stressing oftendons in post -tensioned concrete and - - ACI 318: 26102 - prior to removal of shores and forms from . beams and structural slabs. 12. Inspect formwork for shape, location and dimensions of the concrete member being - - ACI 318: 26.10.1 (b) - formed_ TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS TYPE CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECT10N 1. Verify element materials. sizes and lengths comply with X - the req uirem ents_ 2. Determine capacities of test elements and conduct x - additional load tests. as re uired. 3. Inspect driving operations and maintain complete and x - accurate records for each element. 4_ Verify placement locations and plumbness. confirm type and size of hammer. record number of blows per foot of penetration. determine required penetrations to X - achieve design capacity. record tip and butt elevations and document any damage to foundation element. 5_ For steel elements, perform additional special inspections in accordance with Section 1705 2. 6_ For concrete elements and concrete -filled elements. perform Tests and additional special inspections in - - accordancewith Section 1705 3. 7. For specialty elements, perform additional inspections as determined by the registered design professional in - - responsible char e. ABBREVIATIONS AB ANCHOR BOLT ABV ABOVE AFF ABOVE FINISH FLOOR ALT ALTERNATE ALUM ALUMINUM APPROX APPROXIMATE AYC ALASKAN YELLOW CEDAR BB BOX BEAM BF BOTTOM FLUSH BLDG BUILDING BLKG BLOCKING BM BEAM BOT BOTTOM BP BOTTOM PLATE BRG BEARING BTWN BETWEEN BSMT BASEMENT B/W BOTTOM OF WALL CANT CANTILEVER CJ CONTROL JOINT CLG. CEILING CLJ CEILING JOIST CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONN CONNECTION CONST CONSTRUCTION CONT CONTINUOUS CTR CENTER DET DETAIL DF DOUGLAS FIR (SOUTH) DFL DOUGLAS FIR LARCH DIM DIMENSION DJ DOUBLE JOIST DIA DIAMETER DIN DOWN DS DOWN SPOUT EA EACH EF EACH FACE EJ EXPANSION JOINT ELEV ELEVATION EN EDGE NAILING (PANEL) EQ EQUAL ES EACH SIDE EW EACH WAY FB FLUSH BEAM FIN FINISH FL FLOOR FLSHG FLASHING FND FOUNDATION FP FIREPLACE FT FOOT FTG FOOTING GA GAUGE GALV GALVANIZED GLIB GLULAM BEAM GR GRADE GYP GYPSUM WALL BOARD HDG HOT -DIPPED GALVANIZED HDR HEADER HF HEM FIR HGT HEIGHT HT HEIGHT IN INCH IT JOINT MAX MAXIMUM MIN MINIMUM MISC MISCELLANEOUS NB NON -BEARING NO NUMBER OC ON CENTER PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED RAF RAFTER REF REFERENCE REINF REINFORCEMENT REQD REQUIRED SF SQUAREFOOT SIM SIMILAR SPF SPRUCE PINE FIR STD STANDARD SYP SOUTHERN YELLOW PINE T/ TOP OF T/C TOP OF CONCRETE T/P TOP OF PLATE T/S TOP OF STEEL T/W TOP OF WALL TF TOP FLUSH TJ TRIPLE JOIST T/BM TOP OF BEAM T/SLAB TOP OF SLAB TIP TOP PLATE TYP TYPICAL UNO UNLESS NOTED OTHERWISE UPA UNDER POST ABOVE UWA UNDER WALL ABOVE VERT VERTICAL VIF VERIFY IN FIELD W/ WITH WC WESTERN CEDAR WP WATERPROOF WWF WELDED WIRE FABRIC i • � . T .H �J�X.4 • - All, '. ONA L . W � v7 ZLU W Z Z W ZWZLU Z (D z OOW J REVISIONS DESCRIPTION DATE BY PROJECT NAME 215 OLYMPIC AVE, EDMONDS, WA 98020 NUMBER S220112-1 XR DRAVviu ui - NJ CHECKED BY M RT SHEET DATE 1 /15/22 SIL, U) W RjCEI ED Air 28 2 22 ITY OF EDM D LOPMENT SE DS RVICES DEPARTME T U D DC o Q � DC (n V W Lf, z w w w LU 3 of 4 uu Z_ J H W 13. a PROPERTY LINE 108'-0" * LOCATE PILES ON EACH CORNER OF WINDOW AREA OF WORK LOCATE PILE WITHIN 2FT MAX 8'-0" * A5'-OF CORNER ----------------- --------------- PILES a� 8'-0" O.C. MAX LOCATE PILE: 'HIN 3FT MAXr_,, DECK (3) P1TS @ 8'-0" O.C. MAX 7 8 �90 PARCEL NO. 00434204101700 LEGAL DESCRIPTION CITY OF EDMONDS BLK 041 D-00 - E 5FT LOT 17 & ALL LOTS 18 & 19 LESSS 5FT FOR ALLEY ALSO BEG SW COR TH N ALG W LN 105FT TO EDMONDS ST TH E ALG S LN SD ST 12.15FT TH S 105FT TAP ON S LN TH W 12.7FT TO TPB EXC S 5FTFOR ALLEY OWNER NAME & ADDRESS MANSFIELD LINDA A & BRUCE TAMI TAYLOR 215 OLYMPIC AVE, EDMONDS, WA 98020 LOT SIZE: .19 ACRE(S) (8,276 SQFT) BUILDING LOT COVERAGE: 29% (2,449 SQFT) 108'-0" * LOCATE PILE WITHIN 2FT MAX OF CORNER LOCATE PILES 0 24 EACH CORNER 0 WINDO\ I I I (2) PILES,@ 8'-0" O.C. MAX 3 U , O 4 ' LOCATE PIL WITHIN 1FT MA OF CORNE 0 N I PRIMARY ENTRANCE ED 0 0 N PROPERTY LINE NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. SITE PLAN LEGEND EXISTING RESIDENCE STRUCTURE EXISTING ADJACENT STRUCTURE AREA OF PROPOSED WORK * PROPERTY LINE ---- APPROXIMATE DIMENSION �# HELICAL PILE # STABIL-LOC PILE ® EXISTING POST ® 4x4 POST BASE WITH PAD PILE SPACING & LOAD REQUIRMENTS TABLE MAX O.C. SPACING, ft MIN VERTICAL CAPACITY, kips PROOF TESTING LOAD, kips PILE # PILE TYPE BTWN PILES END OFFSET ALLOWABLE LOADING 200% MIN VERTICAL CAPACITY (MIN ULTIMATE CAPACITY LOCATION 3-8,11,14 HELICAL 8'-0" UNO T-0" UNO 13.0 kip 26.0 kip TYF 9,10,12,13 HELICAL 8'-0" UNO T-0" UNO 11.0 kip 22.0 kip TYP 1.2 HELICAL 8'-0" UNO T-0" UNO 10.0 kip 20.0 kip TYP 1 DRIVEN 8'-0" UNO T-0" UNO 13.0 kip 26.0 kip T P FOUNDATION NOTES 1. VERIFY ALL DIMENSIONS ON SITE. 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: HELICAL PILES ...................................... 1/SD-1.1 DRIVEN PILES ........................................ 2/SD-1.1 HELICAL PILES w/ STEEL CHANNEL ... 3/SD-1.1 4. REFER TO STRUCTURAL CALCULATIONS PACKAGE DATED MARCH 25, 2022, FOR ADDITIONAL INFORMATION, SPECIFICATIONS, AND REQUIREMENTS. 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED OCT 13, 2021 REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8". HELIX CONFIGURATIONS PER R&R TO MEET LISTED DESIGN STRENGTH WITH APPLICABLE FACTORS OF SAFETY. 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH ± 0'-6" TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION OF 8'-0"O.C. MAXIMUM. 8. ALL SUPPLEMENTAL CHANNELS TO SPAN FROM PILE TO PILE AND EXTEND MIN 6" PAST SUPPORTING PILE EA END. 9. ALL SUPPLEMENTAL CHANNELS TO BE ANCHORED TO THE FOUNDATION WITH 5/8" DIAM. x 4" SIMPSON TITEN HD SCREW ANCHORS (OR APPROVED EQUIVALENT) AT A MAXIMUM SPACING 18"OC. ANCHORS TO BE CENTERED ON OR INSTALLED ABOVE THE CENTER LINE OF THE CHANNEL. 10. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8" THICK MINIMUM WITH 2'-8" HEIGHT (MEASURED FROM B/FTG TO T/CONC) MINIMUM. FIELD VERIFY EXISTING CONCRETE SLAB -ON -GRADE AT PILE ATTACHMENT IS 4" THICK MINIMUM. 11. PARCEL DIMENSIONS PROVIDED BY CITY OF SNOHOMISH ISLAND. NOT TO SCALE. PROPERTY LINE AND RESIDENCE LOCATING DIMENSIONS (WITH ASTERISK, *) APPROXIMATED PER SNOHOMISH COUNTY iMAP AND SEATTLE DEPARTMENT OF CONSTRUCTION AND INSPECTIONS GIS MAPPING TOOLS. NOT TO BE USED FOR LEGAL PURPOSES. 12. SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. NOTES: 14. PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5-0" OR UNTIL REFUSAL, WHICHEVER IS SHALLOWER. a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE MANUFACTURER. THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING, INCLUDING A SAFETY FACTOR NO LESS THAN 2. THE MAXIMUM INSTALLATION TORQUE SHALL NOT DRIVEN PILE REFUSAL CRITERIA: EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY. MAXIMUM ADVANCEMENT OF THE PILE SHALL CONTINUE UNTIL A WORKING PRESSURE W INSTALLATION TORQUE RATING OF 8,30OFT*LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.203 INCH SHAFT WALL IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A Z THICKNESS PER ESR-3750. J b. FOR HELICAL PILES, PER IDEAL GROUP DWG NO.: 278TFG, THE ALLOWABLE STRUCTURAL CAPACITY FOR THE 2 7/8" SAFETY FACTOR OF NO LESS THAN TWO. ADVANCEMENT SHALL BE HALTED >_ TRU-FORCE UNDERPINNING BRACKET IS LIMITED TO 29 KIPS. IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. F- c. HELICAL ASSEMBLIES AS MANUFACTURED BY IDEAL MANUFACTURING, INC., IN ACCORDANCE WITH ESR-3750. W d. CONCENTRIC DRIVEN PILES AS MANUFACTURED BY STABIL-LOC SYSTEMS, LLC, IN ACCORDANCE WITH ESR-4121. e. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART HELICAL PILE REFUSAL CRITERIA: 0 wOF THE ASSEMBLY. TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS a f. MAXIMUM ON -CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO. ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. RVE' I ILOEV F CCORNER OF WINDOW LOCATE PILE WITHIN 2FT MAX OF CORNER LOCATE PILE WITHIN 3FT MAX - OF CORNER 7 - v 99, oor i ft18 i I 3 2 5 5-( - Is -3 2 4 1 -25/8 _.. 1 I(6) PILES @ 8'-0" O.C. MAXI zo 314 47' (2) PILES @ 8'-0" O.C. MAX LOCATE PILE 1 WITHIN 2FT MAX OF CORNER LOCATE PILES ON EACH CORNER OF -2 4 WINDOW Ei 1 -41/ (2) PILES @ 8'-0" O.C. MAX ® = Existing Post 3 rn 3" Helical Pile -2 1 !4 14 3" 3" Stabil-Loc Pier -1 3L4 - 44 t with Patl Base :�draclk R&R LEVEL SURVEY SEE STRUCTURAL CALCULATION PACKAGE FOR ADDITIONAL REQUIREMENTS FOUNDATION PLAN +*..... r kr r k+ s W 0 Q Zo W Z r� It w w V zWz Z z O O w J REVISIONS 0 DESCRIPTION DATE BY PROJECT NAME 215 OLYMPIC AVE, EDMONDS, WA 98020 PRE,__, NUMBER S220112-1 XR DRAm,j ui - NJ CHECKED BY M RT SHEET DATE 3/25/22 SLJ RECEIIIED Apr 28 2 22 CITY OF EDM DEVELOPMENT SE DS RVICES DEPARTME T o Q J a � C/) u W p U) w w cn 4 of 4 w�� =QLu z�w z O o O F- U M (E) WOOD FRAMED FLOOR SYSTEM, FIELD VERIFY 8" MIN THICKNESS, CONTRACTOR TO VERIFY d d d IIII=IIII-1 ° d ° - IIII=IIII '- �=IIII=1d ' ''I_II1I=IIII=IIII= (E) CONTINUOUS CONC FOOTING NOTES: 1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET. 2. ALL ASSEMBLY COMPONENTS TO BE GALVANIZED PER ASTM Al53/A123. 3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL REINFORCEMENT SHALL BE SEALED OR COATED TO PREVENT CORROSION. (E) CONC STEM WALL T/STEM WALL = FIELD VERIFY T/FIN GRADE _ VARIES =TI11=lilt=l1 ( E) FTG TO BE CUT FLUSH ' IIII=IIII=IIII= =IIII =IIII =III, WITH FACE OF STEM WALL 1111=1111-11 II , WITH A 12" MAX WIDTH FOR -IIII =IIII IIII INSTALLATION POCKET ' IIII=IIII= 11= IIII=11 =IIII. III _IIII—IIII=11, T/CONC FTG = IIII=IIII FIELD VERIFY IIII—IIII= IIII=IIII IIII=IIII- IIII=IIII="' IDEAL HELICAL PILE & REPAIR BRACKET ASSEMBLY PER R&R FOUNDATION SPECIALIST TO CONFORM TO ESR-3750 (E) WOOD FRAMED FLOOR SYSTEM, FIELD VERIFY ---------- 8" MIN THICKNESS, (E) CONC STEM WALL T/STEM WALL = FIELD VERIFY CONTRACTOR TO VERIFY T/FIN GRADE _ IIII=IIII=IIII. VARIES ' i V 11�1111=IIII=11, ' q 11=IIII=IIII=� '- IIII=IIII=IIII= ' '�' 11=IIII=IIII=11, IIII=IIII=IIII= - 11=IIII=IIII=III .. IIII=IIII=IIII- VFTG ' 11=IIII=IIII=IIII IIII= I1II 1= 1II 1= 1II 1= 1III—II 1= III 1I I_ II CONC F/ ELLD VERIFY h � '' ='III-IIII=IIII=IIII � �- �- � 11=IIII=11 -IIII =IIII = i ' d IIII =IIII = WEDGE ANCHORS PER STABIL-LOC REQUIREMENTS ''ll=_ I=IIII _ _ 11=IIII=IIII= (E) CONTINUOUS CONC FOOTING l NOTES: - 1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE TA NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET. 2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED HOLES. CORROSION PREVENTION COATING J SYSTEM BY OTHERS. PRIME AND PAINT PER MFR OR GALVANIZATION Q PER ASTM 153/A123. 3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL w w REINFORCEMENT SHALL BE SEALED OR COATED TO PREVENT a_ U) CORROSION. 'o �"ip STABIL-LOC CONCENTRIC PIER ASSEMBLY PER R&R FOUNDATION SPECIALIST TO CONFORM TO ESR-4121 (E) WOOD FRAMED " FLOOR SYSTEM, FIELD VERIFY - - - - - - - - - - - - - - - - - - - - - - - I I I I I I I I I • V 8" MIN THICKNESS, CONTRACTOR TO VERIFY (E) CONC STEM WALL T/STEM WALL = FIELD VERIFY T/FIN GRADE _ L IIII=IIII=IIII vARIEs IIII IIII=IIII=1 �v CONTINUOUS CHANNEL — — & ANCHORAGE WHERE ° d 'IIII =IIII =IIII = (E) FTG TO BE CUT FLUSH REQ'D PER PLAN -IIII =IIII =IIII WITH FACE OF STEM WALL " IIII =IIII =IIII = _ WITH A 12" MAX WIDTH FOR (L CHANNEL A =1111= II 11= IF � INSTALLATION POCKET 6, MAX =IIII=IIII_1111= " IIII=IIII IIII=III T/CONC FTG = FIELD VERIFY —IIII=IIII=IIII=IIII=IIII d d IIII=IIII "—"'�=IIII=IIII=11 '- III=IIII=� IIII=IIII V ' d v IIII=IIII: 11 III=IIII= — . d � d (E) CONTINUOUS CONC FOOTING NOTES: 1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET. 2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED HOLES. CORROSION PREVENTION COATING SYSTEM BY OTHERS. PRIME AND PAINT PER MFR OR GALVANIZATION PER ASTM 153/A123. 3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL REINFORCEMENT SHALL BE SEALED OR COATED TO PREVENT CORROSION. IDEAL HELICAL PILE & REPAIR BRACKET ASSEMBLY PER R&R FOUNDATION SPECIALIST TO CONFORM TO ESR-3750 � HELICAL PILE INSTALLATION DETAIL I 2 DRIVEN PILE INSTALLATION DETAIL I 3 HELICAL PILE w/ STEEL CHANNEL INSTALLATION DETAIL 4 INOTUSED 1 5 INOTUSED 1 6 INOTUSED t �ryF 'i�r1.'y '� • W Zo W z z 0 W z W z Z z O O w 0 REVISIONS Q DESCRIPTION DATE BY PROJECT NAME 215 OLYMPIC AVE, EDMONDS, WA 98020 PRE„_.,, _oEF S220112-1XR L)r,-kvviN oT -NJ CHECKED BY - M RT SHEET DATE 1 /15/22 SCE RECEIVED r 28 2 22 4Y OF EDM LOPMENT S DS RVICES DEPARTME T I— W 0 z O - o Q o o cl- cn af z U ''-' O w LL w