Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED FIR2022-0120+Fire_Sprinkler_Equipment_Specification_Sheets+11.8.2022_4.29.04_PM+3210345
lColumbia Fire 110INKE EB 5v 51 EfA Sf RVICE i REPA MANUFACTURER'S DATA SHEETS (Material Submittal) Prepared For Kisan Town Homes 22810 Edmonds Way, Edmonds, WA 98020 Authority Having Jurisdiction CITY OF EDMONDS Prepared By: Najeeb Habib Columbia Fire Inc. 111 South Findlay St. Seattle WA 98108 Phone: (206) 232-8569 Fax (206) 340-6100 Columbia Fire Project #:2205300 TABLE OF CONTENTS Kisan Town Homes 1. PIPING 2. FITTINGS / COUPLINGS 3. SPRINKLER HEADS AND ACCESSORIES 4. PIPE HANGERS 5. MISCELLANEOUS EQUIPMENT 1. PIPING Tyco Fire Protection Products 6 LAZ E MASTE R CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (TFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch thru 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved City of Los Angeles (Refer to Installation Handbook IH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Worldwide I www.tyco-fire.com Contacts Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900 dated April 2016. Page 1 of 2 APRIL 2016 TFP1915 TFP1915 Page 2 of 2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de -vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. t[�CO BLAZEMASTER is a trademark of The Lubrizol Corporation. Fire Protection Products 2. FITTINGS / COUPLINGS Sprinkler Head Adapters BRASTICTm Adapter Straight Size (inches) Part Number Box Qty 3/4 x 1/2 V5003SBT--101 100 1 x 1/2 V5003SBT-130 50 1 x 3/4 V5003SBT-131 50 900 Elbow 3/4x1/2 V50073SBT-101 100 1 x 1/2 V50073SBT-130 50 1 x 3/4 V50073SBT-131 50 Tee 1 x 1 x 1 V5012SBT-101 50 1 x 1 x 1/2 V5012SBT-130 50 1 x 1 x 3/4 V5012SBT-010 50 * Brass starter thread molded into plastic, virtually eliminating cross -threading. Female Adapter with metal thread insert 3/4 x 1/2 1 x 1/2 1 x 3/4 V5003SBI-101 V5003SBI-130 V5003SBI-131 100 50 10 Spigot Female Adapter 3/4x 1/2 100 with metal thread insert 1 x 1/2+V50032SBI-101 V500325BI-130 50 #a Sprinkler Head 90 3/4 x 1/2 V50073SBI-101 100 with metal thread insert 1 x 1/2 1 x 3/4 V50073SBI-130 V50073SBI-131 50 10 1-1/4x1/2 V50073SBI-166 5 Tee Size (inches) Part Number Box Qty with metal thread insert 1 x 1 x 1 V5012SBI-010 50 3/4x3/4x1/2 V5012SBI-101 10 1 x 1 x 1/2 V5012SBI-130 50 1-1/4x 1-1/4x 1/2 V5012SBI-166 5 1-1/2 x 1-1/2 x 1/2 V5012SBI-209 5 2 x 2 x 1/2 V5012SBI-247 2 1 x3/4x 1/2 V5012RSBI-124 10 1-1/4x 1 x 1/2 V5012RSBI-156 5 1-1/2x 1-1/4x 1/2 V5012RSBI-199 5 2 x 1-1/2 x 1/2 V5012RSBI-237 2 Back to Back Cross 1x1x1/2x1/2(1-1/8)1 V50353SBIS-130 20 with metal thread insert — 1x1x1/2x1/2(t-5n6) V50353SBIL-130 1 Back to Back Tee 11/2x1/2x1(1-1i8) V501133SBIS-075 30 with metal thread insert4& — I 1/2x1/2x1 (t-s/t6) V5011335BIL-075 30 Trusted above aII.T" V�KING� CPVC System Quick Reference Guide CPVC Standard Fittings Tee Size (inches) Part Number Box Qty 3/4 V5011-007 250 Qt 1 V5011-010 100 1-1/4 V5011-012 25 1-1/2 V5011-015 25 2 V5011-020 2 2-1/2 V5011-025 1 3 V5011-030 1 900 Elbow 3/4 V5007-007 250 r 1 V5007-010 100 1-1/4 V5007-012 25 1-1/2 V5007-015 25 2 V5007-020 2 2-1/2 V5007-025 1 3 V5007-030 1 1 x 3/4 V5007R-131 100 450 Elbow 3/4 V5006-007 250 1 V5006-010 100 1-1/4 V5006-012 5 1-1/2 V5006-015 5 2 V5006-020 2 2-1/2 V5006-025 1 3 V5006-030 1 Cross 3/4 V5035-007 10 1 V5035-010 100 1-1/4 V5035-012 5 1-1/2 V5035-015 20 2 V5035-020 1 2-1/2 V5035-025 1 1 x 1 x 3/4 x 3/4 V5035R-131 10 Coupling 3/4 V5001-007 250 1 V5001-010 100 1-1/4 V5001-012 25 1-1/2 V5001-015 25 2 V5001-020 10 2-1/2 V5001-025 1 3 V5001-030 1 Reduced Coupling 1 x 3/4 V5001 R-131 10 1-1/4 x 1 V5001 R-168 5 40 1-1/2 x 3/4 V5001 R-210 5 1-1/2x1 V5001R-211 5 1-1/2x1-1/4 V5001R-212 5 2 x 1 V5001 R-249 2 2 x 1-1/2 V5001 R-251 2 N Reducing Tee Size (inches) Part Number Box Qty r 3/4 x 3/4 x l V501 1 R-102 10 1 x 3/4 x 3/4 V5011 R-125 100 l x 3/4 x l V5011 R-126 10 1 x l x 3/4 V5011 R-131 100 1-1/4x 1 x3/4 V5011R-157 5 1-1/4x 1 x 1 V5011R-158 25 1-1/4x 1 x 1-1/4 V5011R-159 5 1-1 /4 x 1-1 /4 x 3/4 V5011R-167 25 1-1/4x1-1/4x1 V5011R-168 25 1-1/4x 1-1/4x 1-1/2 V5011R-169 5 1-1/2 x 1-1/4 x 3/4 V5011R-201 5 1-1/2x1-1/4x1 V5011R-202 5 1-1 /2 x 1-1 /2 x 3/4 V5011R-210 25 1-1/2x1-1/2x1 V5011R-211 25 1-1/2x 1-1/2x 1-1/4 V5011R-212 5 1-1/2 x 1-1/2 x 2 V5011R-213 5 2 x 2 x 3/4 V5011 R-248 2 2 x 2 x 1 V5011 R-249 10 2 x 2 x 1-1 /4 V5011 R-250 2 2 x 2 x 1-1/2 V5011 R-251 2 2-1/2 x 2-1/2 x 1 V5011 R-289 1 2-1/2 x 2-1/2 x 1-1 A V5011R-290 1 2-1/2 x 2-1/2 x 1-1 /2 V5011R-291 1 2-1/2 x 2-1/2 x 2 V5011R-292 1 3 x 3 x 1-1/2 V5011 R-337 1 3 x 2 V5011 R-338 1 3 x 2-1/2 V5011 R-339 1 Bushing 1 x3/4 V5018-131 100 1-1/4 x 3/4 V5018-167 25 IN 1-1/4x1 V5018-168 25 1-1/2 x 3/4 V5018-210 5 1-1 /2 x 1 V5018-211 25 1-1/2x1-1/4 V5018-212 25 2 x 3/4 V5018-248 2 2 x 1 V5018-249 2 2x1-1/4 V5018-250 2 2x1-1/2 V5018-251 2 2-1/2 x 1 V5018-289 15 2-1/2 x 1-1 /4 V5018-290 1 2-1/2x1-1/2 V5018-291 1 2-1/2 x 2 V5018-292 1 3 x 1-1/2 V5018-337 15 3 x 2 V5018-338 1 3 x 2-1/2 V5018-339 1 Cap 3/4 V5017-007 250 1 V5017-010 100 1-1/4 V5017-012 5 1-1/2 V5017-015 5 2 V5017-020 2 2-1/2 V5017-025 1 3 V5017-030 1 November 2014 CPVC System Quick Reference Guide 3 CPVC Pipe Size (inches) Part Number Box Qty 3/4 34PIPE 240 1 1 PIPE 180 ,ir 1-1/4 114PIPE 105 • • 1-1/2 112PIPE 75 2 2PIPE 60 2-1/2 212PIPE 30 3 3PIPE 15 CPVC Transition Fittings Female Adapter Size (inches) Part Number Box Qty %,rvuveu k.-uuPiirry Size (inches) Part Number Box Qty with metal thread insert Adapter 3/4 V500361-007 10 1-1/4 V5001G-012 30 1 V5003BI-010 50 1-1/2 V5001G-015 25 1-1/4 V5003BI-012 5 2 V5001G-020 15 1-1/2 V5003BI-015 5 2-1/2 V5001G-025 4 2 V5003BI-020 2 3 V5001G-030 2 Spigot Female Adapter 3/4 V50032BI-007 250 Standard Union 3/4 V5033E-007 1 with metal thread insert 1 V50032BI-010 100 1 V5033E-010 1 Male Adapter 3/4 V5004BI-007 10 with metal thread insert 1 V5004BI-010 10 1-1/4 V5004BI-012 5 1-1/2 V5004BI-015 5 2 V5004BI-020 2 Accessories Solvent Cement Test Plug Size (inches) Part Number Box Qty Dauber Quart V5097Q 12 Pint V5097P 12 1/2 V450-005 50 Size (inches) Part Number Box Qty Small V5093-S 100 Large V5093-L 100 Roller N/A a - Brush N/A V5097 24 V5096 12 November 2014 CPVC System Quick Reference Guide 4 Recommended Installation Practices and Precautions for Freedom' CPVC Systems Dos • Install product according to the manufacturer's instructions. • Follow recommended safe work practices. • Make certain that thread sealants, gasket lubricants, or fire stop materials are compatible with BlazeMaster® CPVC. Use only latex -based paints if painting is desired. Keep pipe and fittings in original packaging until needed. Cover pipe and fittings with an opaque tarp if stored outdoors. Follow proper handling procedures. Use tools designed for use with plastic pipe and fittings. • Use proper solvent cement and follow application instructions. • Use a drop cloth to protect interior finishes. • Cut the pipe ends square. • Deburr and bevel the pipe end before solvent cementing. • When solvent cementing, rotate the pipe 1/4 turn when bottoming pipe in fitting socket. • Always apply solvent cement to the pipe first then fitting. • Avoid puddling of solvent cement in fittings and pipe. • Make certain that solvent cement does not run and plug the sprinkler head orifice. • Follow the manufacturer's recommended cure times prior to pressure testing. • Fill lines slowly and bleed the air from the system prior to pressure testing. • Support sprinkler head properly to prevent lift up of the head through the ceiling when activated. Keep threaded rod within 1/16"of the pipe. • Install BlazeMaster CPVC pipe and fittings in wet systems only or specially listed dry systems. • Follow manufacturer'hs recommendations for freeze protection. • Allow for movement due to expansion and contraction. • Renew your BlazeMaster CPVC pipe and fittings installation training every two years. • Follow manufacturer's recommendations on pressure testing. • Follow current NFPA standards for use of antifreeze solutions. Blazemaster' is a registered trademark of Lubrizol Teflon' is a registered trademark of E. I. du Pont de Nemours and Company Crisco' is a registered trademark of the J.M. Smucker Company Regional Headquarters Don'ts • Do not use petroleum or solvent -based paints, sealants, lubricants or fire stop materials. • Do not use any glycol -based solutions as an anti -freeze. • Do not use both Teflon' tape and thread sealants simultaneously. • Do not use solvent cement that exceeds its shelf life or has become discolored or gelled. Do not allow solvent cement to plug the sprinkler head orifice. Do not connect rigid metal couplers to BlazeMaster® CPVC grooved adapters. Do not thread BlazeMaster CPVC pipe. Do not use solvent cement near sources of heat, open flame, or when smoking. Do not pressure test until recommended cure times are met. Do not use dull or broken cutting tool blades when cutting pipe. Do not use BlazeMaster CPVC pipe that has been stored outdoors unprotected and is faded in color. Do not allow threaded rod to come in contact with the pipe. Do not install BlazeMaster CPVC pipe in cold weather without allowing for expansion. • Do not install BlazeMaster CPVC pipe and fittings in dry systems, unless specifically Listed for such use. • Do not use ratchet cutters below 50•F. • Do not use edible oils such as Crisco® as a gasket lubricant. • Do not install tape, insulated wire, or cable in direct contact with BlazeMaster CPVC pipe. Note:This list does not constitute as a complete installation guide. Viking SupplyNet - U.S. East Viking SupplyNet - U.S. Midwest Viking SupplyNet - U.S. West 413 Cranberry Rd 2353 International St 9101 Sorensen Ave. Parsippany, NJ 07054 Columbus, OH 43228 Santa Fe Springs, CA 90670 Phone: 800-845-4645 Phone: 800-926-7757 Phone: 800-366-1727 Fax: 269-818-1639 Fax: 614-527-5818 Fax: 562-944-1058 Viking SupplyNet - U.S. South Viking SupplyNet - Latin America Viking SupplyNet -Canada 100 Piedmont Court, Suite A 2840 SW 42nd St, Port 95 Ind Ctr Blg IV 325 Vaughan Valley Blvd. Doraville, GA 30340 Hollywood, FL 33312 Woodbridge, Ontario L4H 365 Phone: 800-234-2443 Phone: 954-791-1756 Phone: 905-856-3557 Fax: 770-446-3713 Fax: 954-791-1614 Fax: 905-856-3558 November 2014 Viking 1210 N Industrial Park Drive, Hastings, MI 49058,Telephone: (269) 945-9501, Facsimile: (269) 945-95991 www.vikinggroupinc.corn MKT-1089 3. SPRINKLER HEADS AND ACCESSORIES Page 1 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Freedom° Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass -bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire -protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre -assembled with a threaded adapter for installation with a low -profile small -diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push -on", "thread -off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS c u� as UL Listed (C-UL-US-EU): Category VKKW eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass -bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-S43000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom° Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 °F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Standard Cover Plates: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Form No. F_012116 18.04.12 Rev 18.1 Replaces Form No. F_012116 Rev 17.2 (added stainless steel cover plates) Page 2 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = MA, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: A. Heavy Duty Part No. 14047W/B** (available since 2006), or B. Head Cabinet Wrench Part No. 14031 *** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ''/z' ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat -sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly.. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature' (Required)' Number' Number' Number' 13504 or 13642 or Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 15394 Red 218766 218756 13504 or 13642 or Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 15394 Green 218766 218756 Sprinkler Finishes: Brass and ENT Cover Plate Finishers: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. z. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Maximum ambient temperature for cover assembly is 100 °F (38 °C). 4. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 5. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end -user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 6. Stainless Steel versions are not available with any finishes or paint. Form No. F_012116 18.04.12 Rev 18.1 Page 3 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number 1 SIN king Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Flow Pressure Listings and Minimum Area 6 GPM (LPM) PSI(bar) Deflector to Installation Approvals3,5 Spacing Ceiling Type Ft. 155 °F (68 °C), 200 of (93 °C) Temperature (u �`E�'°S Ft. X Ft. (m) (m X m) Rated Sprinklers 12 X 12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14 X 14 13 7.0 (4.3 X 4.3) (49.2) (0.48) Concealed with Cover Plate See Footnotes T9, 10, 8 16 X 16 13 7.0 (4.9 X 4.9) (49.2) (0.48) Refer to Figure 2 Assembly. See Footnote 8. & 11 (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20 X 20 20 16.7 (6.1 X 6.1) (75.7) (1.15) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. I This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. a. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the "Flow' and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and 'Pressure' used. 7 Cover Temperature Rating is 135 of (57 oC). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). a. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 9. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8. 10-C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) 11 Stainless Steel Cover plate temperature rating is 135 °F (57 °C). Stainless Steel Cover Part Numbers: 218761 and 218751 (large diameter). Form No. F_012116 18.04.12 Rev 18.1 Page 4 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Reguirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** ^W. Sprinkler Wrench Part No. 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. 2-1/4" (57 mm) diameter opening required in the ceiling. Step 2: 1 1 Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Sprinkler wrench flat Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Sprinkler frame arms Form No. F_012116 18.04.12 Rev 18.1 Page 5 of 5 FREEDOM° RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1/2" (15 mm) NPT s E N 00 S - 2-9/16" (65 mm) Maximum NOTE: Upon sprinkler activation, the deflector descends to approximately 13116" (21 mm) below the sprinkler body. 2-1/16" (52 mm) Minimum f i- 2-3/4" (70 mm) or 3-5/16" (84 mm) Figure 2: Sprinkler Dimensions and Cover Installation QQ�\�--p C US 7-0 a �2 O c� U� O VII NG All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers - -1 - \- . .... ., Figure 4: Square Cover Assembly 15394 Form No. F_012116 18.04.12 Rev 18.1 Replaces Form No. F-012116 Rev 17.2 (added stainless steel cover plates) 4. PIPE HANGERS CPVC Clamps TOLCOT' Fig. 23 - Hanger for CPVC Plastic Pipe & IPS Steel Pipe Double Fastener Strap (B-Line B3182) Size Range: 3/4" (20mm) thru 3" (80mm) CPVC pipe Material: Pre -Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) sizes 3/4" (2omm) thru 2" (50mm) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm) steel using (2) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre -drilling of a pilot hole in wood is required. Finish: Pre -Galvanized Order By: Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. SAO-. 40004� qw-4mon Part No. CPVC Pipe Size in. (mm) A in. (mm) B in. (mm) C in. (mm) Max. Hanger Spacing R. (m) Fastener Hex Head Size in. (mm) Approx. Wt./100 Lbs. (kg) 23-3/4 3/4" (20) 31/8" (79.4) 19/16" (39.7) 13/16" (30.2) 51/2 (1.67) 5/16" (7.9) 9 (4.1) 23-1 1" (25) 33/8" (85.7) 111/16" (42.9) 13/16" (30.2) 6 (1,83) 5/16" (7.9) 9 (4.1) 23-11/4 11/4" (32) 43/16" (106.4) 23/32" (53.1) 13/16" (30.2) 61/2 (1.98) 5/16" (7.9) 11 (5.0) 23-11/2 11/2" (40) 47/16" (112.7) 27/32" (56.3) 13/16" (30.2) 7 (2.13) 5/16" (7.9) 12 (5.4) 23-2 2" (50) 47/8" (123.8) 27/16" (61.9) 13/16" (30.2) 8 (2.44) 5/16" (7.9) 15 (6.8) 23-21/2 21/2" (65) 53/8" (136.5) 211/16" (68.3) 13/16" (30.2) Consult Factory 5/16" (7.9) 22 (10.0) 23-3 3" (80) 6" (152.4) X (76.2) 13/16" (30.2) Consult Factory 5/16" (7.9) 25 (11.3) Reduced Spacing For IPS Pipe IPS Max. Hanger Pipe Size Spacing Part No. in. (mm) Ft. (m) 23-3/4 3/4 (20) 1'-9" (1.67) 23-1 1" (25) l'-10" (1.83) 23-11/4 11/4" (32) 2-4- (1.98) 23-11/2 11/2" (40) 2-9" (2.13) 23-2 2" (50) 3-6" (2.44) 23-21/2 21/2" (65) Consult Factory 23-3 3" (80) Consult Factory All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 34 B-Line series Fire Protection Solutions OTOLCO' a brand of NIBCO' li Fig. 24 Hanger For CPVC Plastic Pipe G Double Fastener Strap Type - Side Mount Size Range — 3/4 thru 2 inch CPVC pipe. Material — Carbon Steel, Pre -Galvanized. Function — Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals — Underwriters' Laboratories Listed in the USA (UL) and Canada (WL) to support fire sprinkler piping. Meets and exceeds the requirements of N.F.P.A. 13, 13R, and 13D. Features — Figure 24 incorporates features which protect the pipe and ease installation. The flared edge design* protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two hex head self threading screws** furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre drilling of a pilot hole in wood is required. Finish— Pre-G a Ivan i ze d . Order By— Figure number and CPVC pipe size. * Patent Pending ** Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Revision 5/24/2001 CPVC A B C Max. Hanger Fastener Hex Approx. Pipe Size Spacing (Ft.) Head Size Wt./100 3/4 2-5/16 1-5/32 1-3/16 5-1/2 5/16 9 1 2-5/8 1-5/16 1-3/16 6 5/16 9 1-1/4 3 1-1/2 1-3/16 6-1/2 5/16 11 1-1/2 3-1/4 1-5/8 1-3/16 7 5/16 12 2 3-11/16 1-27/32 1-3/16 8 5/16 15 ® Main Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92870 • Ph: 909.737.5599 • Fax: 909.737.0330 Distribution Center • 8790 Fruitridge Road • Sacramento, CA 95826 • Ph: 916.388.7800 • Fax: 916.388.1401 Manufacturing Facility • 4851 Homestead Road, Bldg. 118 • Houston, TX 77028 • Ph: 713.672.0058 • Fax: 713.672.0074 www.tolco.com Pipe Clamps M -5 m 0 iv 3 N Fig. 28 - "Stand -Off" Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe ** TOE= Size Range: — 3/4" (20mm) through 2" (50mm) Material: — Steel, Pre -Galvanized Function: — Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off' design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces. • Unique twist and lock design holds pipe firmly in place and allows retrofit type of installation. • The "Stand -Off' design eliminates the need for wood block extension. • Can be installed on horizontal or vertical piping regardless of mounting surface orientation. • Attaches easily to wood structure with two hex head self -threading screws furnished with product. • Installs easily using rechargeable electrical driver with 5/16" (7.9mm) extension socket eliminating impact tool damage to pipe. • Attaches easily to steel, minimum 18 gauge (1.024mm) with (2) 1/4" x 1" tek type self drilling tapping screws. • UL Listed as a hanger and a restrainer for fire sprinkler piping. Approvals: — Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners supplied with product, or into minimum 18 gauge steel using (2) 1/4" x 1" tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28 satisfies the UL vertical restraint requirement where needed. UL Listed as a hanger and vertical restraint when installed on 3/8" (9.5mm) composite wood material. Use two Fig. 27B Speed Nuts when used as a hanger and restraint. Use one Fig. 27B Speed Nut on the upper installed screw when used as a hanger only. Order by: — Figure number and pipe size. Pat. # 7,455,268, Pat. # 7,832,248 ** With reduced spacing, consult factory. Fig. 27B (1) Required High Side of Hanger ApplicationLi Hanger Application Fig. 27B (2) Required it t4 Hanger and Restraint Application V r Pipe Size A B C Max Hanger Approx. Spacing Wt./100 Part No. in. (nun) in. (mm) in. (mm) in. (nun) Ft. (m) Ibs. (kg) 28-3/4 3/4" (20) 31/32" (77.0) 7" (50.8) 31/2' (88.9) 51/2 (1.67) 18 (8.1) 28-1 V (25) 35/16" (84.1) 23/16" (55.6) 31/2" (88.9) 6 (1.83) 21 (9.5) 28-11/4 11/4' (32) 35/8" (92.1) 23/8" (60.3) 31/2" (88.9) 61/2 (1.98) 23 (10.4) 28-11/2 11/2" (40) 4" (101.6) 21/2" (63.5) 31/2" (88.9) 7 (2.13) 31 (14.0) 28-2 2" (50) 41/2" (114.3) 211/16" (68.3) 35/8" (92.1) 8 (2.44) 34 (15.4) ce us LISTED 9--Li e by Fj-N All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 Fire Protection Solutions CPVC Clamps TOLCOT' Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe Size Range: Available in 3/4' (20mm) and 1" (25mm) pipe sizes Material: Pre -Galvanized Steel Function: Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2" (20mm) x 11/2" (20mm) from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1 " hex head self -threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish: Pre -Galvanized Order By: Figure number and pipe size. Patent Pending CPVC Max Hanger Approx. Pipe size Spacing W000 Part No. in. (nun) R. (m) lbs. (kg) 29-3/4 3/4" (20) 5'-6- (1.67) 18 (8.1) 29-1 1" (25) 6'-0" (1.83) 19 (8.6) Reduced Spacing For IPS Pipe IPS Max. Hanger Pipe Size Spacing Part No. in. (mm) Ft. (m) 29-3/4 3/4' (20) V-9" (1.67) 29-1 1" (25) V-10" (1.83) ®.0 m l Double Offset V 0 Single Offset (38.1mm) O cc, 0 0 Ee c(9us LISTED Install using a rechargeable electric drill fitted with a 5/16" (7.9mm) socket attachment with the special hex head self -tapping screws provided. Install screws until they bottom out. Pipe can be "snapped" into hanger before or after installation of the screws to the mounting surface. "Thumb tab" may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 40 B-Line series Fire Protection Solutions 5. MISCELLANEOUS EQUIPMENT Page 1 of 5 SPRINKLER WRENCHES 4 I Ki AND CABINETS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION A. Sprinkler Cabinets Viking sprinkler cabinets are metal enclosures constructed to store an emergency supply of spare sprinklers and a sprinkler instal- lation wrench. NFPA 13 requires a representative number of each type and temperature rating of sprinkler head to be kept in a cabinet on the premises. NFPA 13 also requires a special sprinkler wrench to be provided in the cabinet. This allows for immediate removal and replacement of sprinklers that have operated or that have become damaged. Stock of spare sprinklers should include sprinklers of all the types and temperature ratings as are installed in the sprinkler system, in the following quantities: Number of Sprinklers in the System Minimum Number of Spare Sprinklers Required Under 300 6 300-1,000 12 Over 1,000 24 B. Sprinkler Wrenches WARNING: Cancer and Reproductive Harm- www. P65 Wa rn i ngs. ca.gov Viking sprinkler wrenches are special installation tools specifically designed for use with the various Viking sprinklers and spray nozzles. The appropriate wrenches must be used with the indicated sprinklers and nozzles to provide the proper leverage when tightening sprinklers or nozzles and to minimize slippage during installation. Using wrenches other than the ones designated for installation may damage the sprinkler. Refer to Tables 2a and 2b and the ap- propriate sprinkler or spray nozzle data page for the correct installation wrenches that must be used. Wrenches 21475M/B, 10896W/B, 07297W/B, 05118CW/B, 13635W/B, and 16888M/B provide the amount of leverage needed to tighten sprinklers and spray nozzles into pipe fittings while preventing sprinkler damage. No additional tools are necessary with these wrenches. The following wrenches require a separate '/2' ratchet (not available from Viking) to provide the correct amount of leverage: 08336W/B, 10366W/B, 07565W/B, 11663W/B, 13032W/B, 13577W/B, 13619, 15466, 13623W/B, 15467W/B, 15209W/R, 13655W/B, 14031, 14047W/B, 16208W/R, and 16267. The internal diameters of sprinkler wrenches 08336W/B, 10366W/B, 15209W/R, 16208W/R, and 16267 are designed for use with the sprinkler contained in the protective shell. (A protective shell should be retained in the spare sprinkler cabinet.) Wrench part number 10551 W/B is required for threading institutional escutcheon plates onto institutional sprinklers. Wrench part number 10729 is a 2-1/2" (63.5 mm) C-C face spanner wrench used for removing institutional escutcheon plates from institutional sprinklers (refer to the DISASSEMBLY section of institutional sprinkler technical data pages). Wrench part number 15915 is optional for removing protective sprinkler caps and for installing E-1 and F-1 Escutcheons on frame style pendent sprinklers from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Refer to Technical Bulletin Form No. 051808. 2. LISTINGS AND APPROVALS Refer to the specific sprinkler or spray nozzle technical data pages for sprinkler listings and approvals. 3. TECHNICAL DATA Specifications: Sprinkler Cabinets: Designed with four 3/16" diameter holes in back. Spacing of mounting holes: 3-1/2" (88.9 mm) length, 3-1/2" (88.9 mm) height. The sprinkler cabinet should be located adjacent to the main system riser. Material Standards: Sprinkler Cabinets: Cold Rolled Steel. Finish: Painted high -gloss red enamel interior and exterior, chrome plated door knob. Wrenches: Ductile Iron, Steel, Acetal, or 50% glass filled nylon (for head cabinet wrenches) Ordering Information: (Also refer to the current Viking price list.) Form No. F_122598 18.10.11 Rev 18.1.P65 Replaces Form No. F_122598 Rev 18.1 (Added P65 Warning.) Page 2 of 5 SPRINKLER WRENCHES 4 I Ki AND CABINETS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com A. Sprinkler Cabinets 1. Determine appropriate cabinet from Table 1 on this page for use with the specific model/number of sprinklers to be contained in the cabinet. 2. Specify cabinet part number and quantity needed. B. Sprinkler Wrenches 1. Determine the appropriate wrench for use with the given sprinkler or spray nozzle model from Tables 2a and 2b. 2. Specify the wrench part number and quantity needed. NOTE: Sprinklers and sprinkler wrenches are not supplied with the cabinets; they must be ordered separately. 4. INSTALLATION Refer to the appropriate sprinkler or spray nozzle technical data page. 5. OPERATION Refer to the sprinkler or spray nozzle techical data page for the particular model used. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking sprinkler wrenches and cabinets are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. OrderingTable 1: Sprinkler Cabinet Cabinet Cabinet Size For Sprinkler Models: Capacity Part No. Length Height I Depth 01724A 10-3/16" 4-11/16" 2-9/16" Viking frame style sprinklers 6 sprinklers Available since 1971. (259 mm) (103 mm) (65 mm) Viking frame style sprinklers, 12 sprinklers ESFR K14 sprinklers, (6 K25.2 EC 01725A 10-3/16" 8-9/16" 2-9/16 K16.8 pendent sprinklers, sprinklers) Available since 1971. (259 mm) (217 mm) (65 mm) and K25.2 EC sprinklers Viking concealed and flush style sprinklers, ESFR K25.2 and K22.4 5-6 sprinklers 01731A 13-13/16" 5-11/16" 3" pendent sprinklers, and K19.6 Available since 1971. (351 mm) (144 mm) (76 mm) CMSA sprinklers High Challenge° Sprinklers, 03985A 12-5/8" 9-1/8" 4-1/8" upright ESFR sprinklers, and Intermediate Level Sprinklers 6 sprinklers Available since 1977 (321 mm) (232 mm) (105 mm) Form No. F_122598 18.10.11 Rev 18.1.P65 Page 3 of 5 SPRINKLER WRENCHES 4 I Ki AND CABINETS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com IMPORTANT NOTES The sprinkler cabinet should be easily accessible. The sprinkler cabinet must not be exposed to corrosive atmospheres or temperatures above 100 °F (38 °C). The stock of spare sprinklers should include an adequate number of sprinklers of each type and temperature rating. The stock of sprinklers must be in good condition. A sprinkler wrench of the appropriate type must be included in the cabinet. Orient sprinklers and sprinkler wrench as indicated in Figure 1 below. CAUTION: When replacing automatic sprinklers in an existing system, be sure to replace with sprinklers of the correct type, thread size, orifice size, temperature rating, and finish. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to the appropriate sprinkler data page. Viking sprinklers and spray nozzles are designed to be installed in accordance with the latest edition of Viking technical data, the latest standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards whenever applicable. The use of certain types of sprinklers may be limited due to occupancy and hazard. Refer to the Authority Having Jurisdiction prior to installation. CAUTION: WHEN REPLACING AUTOMATIC SPRINKLERS IN AN EXISTING SYSTEM, BE SURE TO REPLACE WITH SPRINKLERS OF THE CORRECT TYPE. THREAD SIZE, ORIFICE SIZE. TEMPERATURE RATING AND FINISH. Figure 2: Sprinkler Cabinet 01724A (Sprinklers and wrench not included) Figure 3: Sprinkler Cabinet 01725A (Sprinklers and wrench not included) Form No. F_122598 18.10.11 Rev 18.1.P65 Page 4 of 5 SPRINKLER WRENCHES AND CABINETS -NIKJ The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Table 2a: Sprinkler Wrenches For Sprinkler Models: Use Wrench: Frame -style sprinklers and spray nozzles 21475M/B Available since 2017 Wax coated Frame -style sprinklers and spray 10896W/B Available since 2000 nozzles or 05000CW/B* Wax coated sprinklers and domed 13577W/B Available since concealed pendent sprinklers 2006 replaces 07398W* Recessed horizontal sidewall sprinklers with protective shields, domed concealed 13655W/B horizontal sidewall sprinklers, and recessed Available since 2006 pendent sprinklers Coated and recessed ECOH K14 sprinkler 13032W/B Available since 2004 Standard adjustable and plain barrel dry 07297W/B Available since 1991 sprinklers, K16.8 and ECOH K14 sprinklers Recessed and domed concealed dry sprinklers 07565W/B Available since 1991 High Challenge° sprinklers, upright ESFR 05118CW/B sprinklers, and ELO sprinklers** Available since 1981 Coated, recessed, and domed 11663W/B concealed ELO sprinklers Available since 2001 Pendent K14 and K16.8 ESFR sprinklers 13635W/B double ended (use Side A) Available since 2006, or 10285W/B Pendent K25.2, K22.4 ESFR sprinklers 13635W/B double ended (use Side B) and K19.6 CMSA Sprinkler VK592 Available since 2006, or 12143W/B* Upright EC K25.2 sprinklers 16888M/B Available since 2011 QR and EC Concealed Sprinklers VK461, 14031t VK462, VK463, VK464, VK465, VK632, and Available since 2006 VK634 (also optional for cap removal) QR and EC Concealed Sprinklers 14047W/B (heavy duty) VK461, VK462, VK463, VK464, VK465, Available since 2006 VK632, and VK634 Residential Concealed Sprinklers VK456, VK457, VK474, and VK488 13619t (red) Available since 2006 (also optional for removal of protective caps) *Wrench no longer available. May still be used until wrench replacement is necessary. * *ELO sprinklers manufactured before Dec. 2001 use wrench part number 07297W/B (07565W/B for coated and recessed). tldeal for sprinkler cabinets. �f47� Part No. 21475M/B 9�=39 m Part No. 10896W/B Part No. 13577W/B & 13032W/B Part No. 07297W/B Part Nos. 07565W/B Part No. 13655W/B & 11663W/B Part No. 05118CW/B 13635 5 Part No. 13635W/B 0 � Part No. 16888M/B Part No. 14031 Part No. 14047W/B Figure 4a: Sprinkler Wrenches Form No. F_122598 18.10.11 Rev 18.1.P65 Page 5 of 5 SPRINKLER WRENCHES 4 I Ki AND CABINETS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Table 2b: Sprinkler Wrenches For Sprinkler Models: Use Wrench: Residential Concealed Sprinklers 13623W/B (heavy duty) VK456, VK457, VK474, and VK488 Available since 2006 Residential Concealed HSW Sprinkler VK480 16267t or 16208W/R (heavy duty)Available since 2010 Mirage° QR ELO Concealed Sprinklers 15466t VK636 and VK469 (also optional for Available since 2009 removal of protective caps) Mirage® QR ELO Concealed Sprinklers 15467W/B (heavy duty) VK636 and VK469 Available since 2009 Mirage® Concealed and flush style sprinklers 08336W/B (heavy duty) Available since 1993 Mirage° Concealed and flush style sprinklers 10366W/Bt Available since 1998 Residential Flush Pendent Sprinklers 15209W/R (heavy duty) VK476 and VK478 Available since 2009 18315 (heavy duty) Recessed Flush Dry Sprinklers VK482 Available since 2014 Mirage° and Freedom° Concealed Sprinklers VK461, VK462, VK463, VK464, VK465, 14412t, or 14867 for the large VK469, VK474, VK632, VK634, VK636, and diameter cover, Available since 2007 VK488 (optional concealed cover installer tool) Shipping Cap Remover/ 15915t Available since 2010 Escutcheon Installer (optional—) Institutional style flush sprinklers 10551 W/B (for installation of the escutcheon plate) Available since 1999 Institutional style flush sprinklers (spanner 10729 Available since 1999 wrench for escutcheon plate removal) —Allows removal of sprinkler caps and installation of E-1 and F-1 escutcheons on frame style pendent sprinklers from the floor. tldeal for sprinkler cabinets. n L-- Part Nos. 13619 Part Nos. 13623W/B & 15466 & 15467W/B Cl C Part No. 16267 Part No. 16208W/R O Part No. 08336W/B Part No. 10366W/B 0 Part No. 15209W/R Part No. 14412 I � I Part No. 14867 Part No. 15915 Part No. 10551 W/B Part No. 10729 01 Part No. 18315 Figure 4b: Sprinkler Wrenches Form No. F_122598 18.10.11 Rev 18.1.P65 Replaces Form No. F_122598 Rev 18.1 (Added P65 Warning.) ARGCO Fire Sprinkler Pressure Gauges u� 0-300 psi water FM 0-300 psi air 0-300 psi air/water Application: Fluid medium which does not clog connection port or corrode copper alloy. Specifically designed for the fire sprinkler industry. Size: 4" (100 mm) Accuracy ± 3/2/3% of span (ASME B40.1 Grade B) Working Range Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40OF to 140OF (-40°C to 60°C) Media: max. 140°F (+60°C) Approvals UL listed (UL-393) FM approved Meets NFPA 25 Standards Temperature Error Standard Scale Additional error when temperature changes from reference temperature of 680F PSI (20°C) +0.4% for every 18' F (10°C) rising or falling. Percentage of span. Standard Features Connection Material: copper alloy Lower mount (LM) - not available for 11/2" size 1/4" NPT limited to wrench flat area Bourdon Tube: Material: copper alloy C-type Movement: Copper alloy, silicone dampened Dia: White plastic with stop pin - black & red lettering Pointer: Black aluminum Case: Black polycarbonate E Window Acrylic, ultrasonically welded to case Standard Series • Type 110.10sp Order Options water air/water air 4` NF' The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM NOTES: SINGLE SCALE ARC = 270.0° SCALE = 300 ps MINOR INCREMENTS = 5 psi INTER. INCREMENTS = 10 psi MAJOR INCREMENTS = 50 psi ALL MARKINGS = BLACK RED (PMS032) Columbia Fire— B LACK SPRINKLER SYSTEM SERVICE &REPAIR � RED (PMS032) Seattle, WA = g LAC K 206-232-8569 ,o 150 100 200 Columbia Fire �50 250E -� Seattle, WA j 206-232-8569 Q WATER 300 `� /�� PRESSURE GAUGE FOR FIRE PROTECTION SERVICE ((++ C UL US ` FM nJlAPPROVED N LISTED 30SM \ ASSEMBLED IN USA D4001 419 CERTIFICATE OF COMPLIANCE IVika Instrument, LP Certifies that the products specified hereir }ave been manufactured in accordance with established echnical standards, and comply with the requirements of kNSIIASME B40.100 CUSTOMER Allied Rubber & Gasket Co 5400 S 66 St FORT SMITH, AR 72903 CUSTOMER P.Q. NO. ORDER NO. ORDER DATE CUSTOMER PIN WIKA PIN DESCRIPTION QUANTITY 41945 2018647 04/14/2015 6510161 IWIKA11 WIKA Instrument, LP 1000 Wiegand Boulevard LAWRENCEVILLE, GA 30043 Tel: (+1) 770-513 8200 Fax: (+1 ) 770-338 5118 http://www.wika.00m info@wika.com 4276192 111.10SP 4 3001PS 1/4 L WATER ARGCO :ii' AUTHORIZED SIGNATURE DATE 04/15/2015 T R i 4 CERTIFICATES of COMPLIANCE AINSUAS4 1 ❑sao�-�ooe I 9/9/2016 Fire Sprinkler Plates verified Secure I Customer Approved Fire Spnnkler Plate G'1I 0 Call Us 800-274-6271 Email Us Chat Live Sign In or Register Foietysign.com ISeamh by Keyword or Item # Search 0 Cart Empty Safety Signs Traffic Signs Parking Signs Property Signs Facility Signs Emergency Signs Safety Labels Tags More SafetySign.com > Fire / Exit / Emergency > Fire Sprinkler Signs > Sprinkler System Plates Fire Sprinkler Plates The National Board of Fire Underwriters (NBFU) has a number of mandates that apply to fire and alarm signs to ensure facilities are as safe as possible in the event of an emergency. NBFU Standard Number 13 applies to facilities that have a Fire Sprinkler System and mandates that a variety of Fire Sprinkler Signs and Fire Sprinkler System Plates be placed throughout the building. Through SafetySign.com, you can find all the Fire Sprinkler System Plates and Fire Sprinkler Signs needed to comply with NBFU No. 13 standards. These Fire Signs are clearly marked and are constructed with durable materials and are made to last., Browse our selection of Fire Sprinkler System Plates and Fire Sprinkler Signs, and then order these and other Fire Department Signs to remain in compliance today. Fire / Exit / Emergency Custom Emergency Signs Emergency Signs Exit Signs Fire Department Connection Signs Fire Door Signs Fire Extinguisher Signs Fire Sprinkler Signs Fire Alarm Sprinkler Signs Fire Sprinkler Pipe Markers NFPA 170 Symbol Signs SPRINKLER SYSTEM PLATES Sprinkler System Signs Flammable and Hazmat Signs NFPASigns Accessories Hydraulic System Automatic Sprinkler Plate Plate Item SPRA ALM Item SPR-2ALM Sort by Relevance Sprinkler Alarm Plate Alarm Line Plate Alarm Test Plate Item SPR-15 Item SPR-3ALM Item SPR-4ALM Auxiliary Drain Plate Control Valve Plate Drain Plate Filling Line Plate Anti -Freeze Plate Item SPR-5ALM Item SPR-6ALM Item SPR-7ALM Item SPR-BALM Item SPR-9ALM Inspection Test Plate Main Control Plate Main Drain Plate Shut -Off Valve Plate Water Motor Line Item SPR-10ALM Item SPR-11 ALM Item SPR-12ALM Item SPRA 3ALM Plate Item SPR-14ALM ALARM LINE ALARM TEST bHfl-FREQE $YSiEN AUXILIARY ORAIH AUTOMATIC SPRINKLER SHUT-OFF Alarm Line Plate Alarm Test Plate Anti -Freeze Plate Auxiliary Drain Plate Shut -Off Valve Plate Item 25745 Item 25746 Item 25747 Item 25748 Item 25749 DRAIN VALVE TEST VALVE MAIN QRAIN MAIN CONTROL DRl' STANDPIPE Drain Valve Plate Test Valve Plate Main Drain Plate Main Control Plate Dry Standpipe Plate Item 25750 Item 25751 Item 25752 Item 25753 Item 25754 WET 5TANOPIPE STANOPIPESYSTEM COMBINATION INSPECTORS TEST SPRINKLER ROOM STANDPIPE http://www.safetysign.com/fire-sprinkler-plates 1/2 9/9/2016 Fire Sprinkler Plates Wet Standpipe Plate Standpipe System Standpioe Plate Inspection Test Plate Sprinkler Room Plate Item 25755 Plate Item 25757 Item 25758 Item 25759 Item 25756 NKLEfl CDNTRDLIVALVE SPRINKLIERALARM gNBASEMENT ONLY CELLARONLY Control Valve Plate Sprinkler Riser Plate Sprinkler Alarm Plate Sprinkler System Sprinkler System Item 25760 Item 25761 Item 25762 Sian Sian Item 25656 Item 25653 EMERGENCY GAS SHUT-OFF Sprinkler Valve Sian Sprinkler Sian Emeraencv Gas Shut - Item 25654 Item 25655 Off Sian Item 25657 Low Price Guarantee Made in USA Fast Shipping We sell high quality safety signs at the All our safety signs are manufactured Thousands of products ready to ship lowest prices. If you can find our signs by us in New Jersey. We are a veteran same day at low discounted UPS® at a lower price, we'll match it! owned and operated company. and FedEx® rates. Site Information Learning Center Your Shopping Information Brimar Credit & Distributors About Us Frequently Asked Questions My Account Open a Brimar Net 30 Account Privacy Policy How To Create a Custom Sign Shopping Cart Brimar W-9 Form Contact Us Shipping Help Track Your Order Become A Distributor Terms & Conditions ANSI Z535 2007 Revision Forgot Password Credit Application Site Map ANSI Z535.4 Safety Labels Returns ANSI Z535 Safety Headers Safety Sign News & Articles ANSI Z535 Safety Symbols SafetySign.com Blog The Sign Genius Follow Us! Shipments Via: i�c- We Accept: �r�+ resa W ,- �K � 3;;;;,,�;;;,� Toll -Free Phone: 800-274-6271 • Toll -Free Fax: 800-279-6897 64 Outwater Lane, Garfield, NJ 07026 SafetySign.com is a division of Brimar Industries, Inc. More Brimar products Phone: 973-340-7889 • Fax: 973-340-7809 • sales(cDsafetysign.com available from WaferSeals.com, PioeMarker.com, and Siqns of Security. © 1988-2016 Brimar Industries, Inc. All rights reserved http://www.safetysign.com/fire-sprinkler-plates 2/2