Loading...
REVIEWED BLD2022-0846+Structural_Analysis_or_Calculations+6.29.2022_1.24.08_PM+2961826 STRUCTURAL CALCULATIONS Wilkie Residence Remodel 24301 101st Ave W Edmonds, WA 98020 CG Project No.: 22145.10 250 4th Ave S Ste 200 Edmonds, WA 98020 Phone: (425) 778-8500 Fax: (425) 778-5536 06/28/2022 RECEIVED Jul 07 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2022-0846 REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT Project Description Scope of Work Basis of Design Roof Dead 15 psf Live 25 psf (snow) Floor Dead 15 psf Live 40 psf BTJ 6/10/2022 NTS 22145.10 Project Summary Wilkie Residence This project involves the remodel of an existing single-family resience. The remodel consists of vaulting the ceiling over the kitchen/dining room area and removing an existing bearing wall. A new ridge beam, posts, and foundations are required for the proposed remodel. The existing roof rafters will remain in place and new rafters will be added in between them. We will provide stamped structural calculations in accordance with the current building code. Description Project250 4th Ave South Suite 200 Edmonds, WA 98020 By Checked Scale Job No. Date Sheet No. Date 1 2 ROOF KEY PLAN 3 4 COMPANY May 26, 2022 14:53 PROJECT BM-R1.wwb Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Load1 Dead Full UDL 165.0 plf Load2 Snow Full UDL 275.0 plf Self-weight Dead Full UDL 14.2 plf Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 18.606' 18.5'0' Unfactored: Dead 1666 1666 Snow 2558 2558 Factored: Total 4224 4224 Bearing: Capacity Beam 4224 4224 Support 4359 4359 Des ratio Beam 1.00 1.00 Support 0.97 0.97 Load comb #2 #2 Length 1.27 1.27 Min req'd 1.27 1.27 Cb 1.00 1.00 Cb min 1.00 1.00 Cb support 1.07 1.07 Fcp sup 625 625 Glulam-Unbalan., West Species, 24F-1.8E WS, 5-1/8"x12" Supports: All - Timber-soft Beam, D.Fir-L No.2 Total length: 18.63'; Clear span: 18.375'; Volume = 7.9 cu.ft.; 8 laminations, 5-1/8" maximum width, Lateral support: top = continuous, bottom = at supports; This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 91 Fv' = 305 psi fv/Fv' = 0.30 Bending(+) fb = 1896 Fb' = 2760 psi fb/Fb' = 0.69 Live Defl'n 0.55 = L/406 0.93 = L/240 in 0.59 Total Defl'n 1.08 = L/205 1.23 = L/180 in 0.87 Additional Data: FACTORS: F/E(psi) CD CM Ct CL CV Cfu Cr Cfrt Notes Cvr LC# Fv' 265 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 2400 1.15 1.00 1.00 1.000 1.000 - - 1.00 1.00 - 2 Fcp' 650 - 1.00 1.00 - - - - 1.00 - - - E' 1.8 million 1.00 1.00 - - - - 1.00 - - 2 Eminy' 0.85 million 1.00 1.00 - - - - 1.00 - - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D + S Bending(+): LC #2 = D + S Deflection: LC #2 = D + S (live) LC #2 = D + S (total) Bearing : Support 1 – LC #2 = D + S Support 2 – LC #2 = D + S D=dead S=snow All LC's are listed in the Analysis output Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1 CALCULATIONS: V max = 4201, V design = 3723 lbs; M(+) = 19430 lbs-ft EIy = 1328.38 lb-in^2 "Live" deflection is due to all non-dead loads (live, wind, snow…) Total deflection = 1.5 dead + "live" Design Notes: 1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Glulam design values are for materials conforming to ANSI 117-2015 and manufactured in accordance with ANSI A190.1-2012 4. GLULAM: bxd = actual breadth x actual depth. 5. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 6. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). 5 COMPANY May 26, 2022 14:56 PROJECT BM-R2.wwb Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Load1 Dead Full UDL 98.0 plf Load2 Snow Full UDL 163.0 plf Self-weight Dead Full UDL 17.7 plf Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 18.565' 18.5'0' Unfactored: Dead 1073 1073 Snow 1513 1513 Factored: Total 2586 2586 Bearing: Capacity Beam 2586 2586 Support 2669 2669 Des ratio Beam 1.00 1.00 Support 0.97 0.97 Load comb #2 #2 Length 0.78 0.78 Min req'd 0.78 0.78 Cb 1.00 1.00 Cb min 1.00 1.00 Cb support 1.07 1.07 Fcp sup 625 625 Glulam-Unbalan., West Species, 24F-1.8E WS, 5-1/8"x15" Supports: All - Timber-soft Beam, D.Fir-L No.2 Total length: 18.56'; Clear span: 18.438'; Volume = 9.9 cu.ft.; 10 laminations, 5-1/8" maximum width, Lateral support: top = continuous, bottom = at supports; This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 43 Fv' = 305 psi fv/Fv' = 0.14 Bending(+) fb = 744 Fb' = 2733 psi fb/Fb' = 0.27 Live Defl'n 0.17 = < L/999 0.93 = L/240 in 0.18 Total Defl'n 0.34 = L/649 1.23 = L/180 in 0.28 Additional Data: FACTORS: F/E(psi) CD CM Ct CL CV Cfu Cr Cfrt Notes Cvr LC# Fv' 265 1.15 1.00 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 2400 1.15 1.00 1.00 1.000 0.990 - - 1.00 1.00 - 2 Fcp' 650 - 1.00 1.00 - - - - 1.00 - - - E' 1.8 million 1.00 1.00 - - - - 1.00 - - 2 Eminy' 0.85 million 1.00 1.00 - - - - 1.00 - - 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D + S Bending(+): LC #2 = D + S Deflection: LC #2 = D + S (live) LC #2 = D + S (total) Bearing : Support 1 – LC #2 = D + S Support 2 – LC #2 = D + S D=dead S=snow All LC's are listed in the Analysis output Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1 CALCULATIONS: V max = 2578, V design = 2221 lbs; M(+) = 11923 lbs-ft EIy = 2594.49 lb-in^2 "Live" deflection is due to all non-dead loads (live, wind, snow…) Total deflection = 1.5 dead + "live" Design Notes: 1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Glulam design values are for materials conforming to ANSI 117-2015 and manufactured in accordance with ANSI A190.1-2012 4. GLULAM: bxd = actual breadth x actual depth. 5. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 6. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). 6 7 COMPANY May 26, 2022 14:58 PROJECT BM-R3.wwb Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Load1 Dead Full UDL 30.0 plf Load2 Snow Full UDL 50.0 plf Self-weight Dead Full UDL 4.0 plf Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 5.542' 5.5'0' Unfactored: Dead 94 94 Snow 139 139 Factored: Total 233 233 Bearing: Capacity Beam 709 709 Support 1211 1211 Des ratio Beam 0.33 0.33 Support 0.19 0.19 Load comb #2 #2 Length 0.50* 0.50* Min req'd 0.50* 0.50* Cb 1.00 1.00 Cb min 1.00 1.00 Cb support 1.11 1.11 Fcp sup 625 625 *Minimum bearing length setting used: 1/2" for end supports Lumber-soft, Hem-Fir, No.2, 4x6 (3-1/2"x5-1/2") Supports: All - Timber-soft Beam, D.Fir-L No.2 Total length: 5.56'; Clear span: 5.438'; Volume = 0.7 cu.ft. Lateral support: top = continuous, bottom = at supports; This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 15 Fv' = 172 psi fv/Fv' = 0.09 Bending(+) fb = 216 Fb' = 1271 psi fb/Fb' = 0.17 Live Defl'n 0.02 = < L/999 0.28 = L/240 in 0.06 Total Defl'n 0.03 = < L/999 0.37 = L/180 in 0.09 Additional Data: FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC# Fv' 150 1.15 1.00 1.00 - - - - 1.00 1.00 2 Fb'+ 850 1.15 1.00 1.00 1.000 1.300 - 1.00 1.00 1.00 2 Fcp' 405 - 1.00 1.00 - - - - 1.00 1.00 - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D + S Bending(+): LC #2 = D + S Deflection: LC #2 = D + S (live) LC #2 = D + S (total) Bearing : Support 1 – LC #2 = D + S Support 2 – LC #2 = D + S D=dead S=snow All LC's are listed in the Analysis output Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1 CALCULATIONS: V max = 231, V design = 191 lbs; M(+) = 318 lbs-ft EIy = 63.08 lb-in^2 "Live" deflection is due to all non-dead loads (live, wind, snow…) Total deflection = 1.5 dead + "live" Design Notes: 1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 8 COMPANY May 26, 2022 15:08 PROJECT BM-R4.wwb Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Load1 Dead Full UDL 167.0 plf Load2 Snow Full UDL 227.0 plf Self-weight Dead Full UDL 8.1 plf Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 10.626' 10.5'0' Unfactored: Dead 930 930 Snow 1206 1206 Factored: Total 2136 2136 Bearing: Capacity Beam 2136 2136 Support 3649 3649 Des ratio Beam 1.00 1.00 Support 0.59 0.59 Load comb #2 #2 Length 1.51 1.51 Min req'd 1.51 1.51 Cb 1.00 1.00 Cb min 1.00 1.00 Cb support 1.11 1.11 Fcp sup 625 625 Lumber-soft, Hem-Fir, No.2, 4x12 (3-1/2"x11-1/4") Supports: All - Timber-soft Beam, D.Fir-L No.2 Total length: 10.63'; Clear span: 10.375'; Volume = 2.9 cu.ft. Lateral support: top = continuous, bottom = at supports; This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 65 Fv' = 172 psi fv/Fv' = 0.38 Bending(+) fb = 901 Fb' = 1075 psi fb/Fb' = 0.84 Live Defl'n 0.11 = < L/999 0.52 = L/240 in 0.22 Total Defl'n 0.25 = L/507 0.70 = L/180 in 0.35 Additional Data: FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC# Fv' 150 1.15 1.00 1.00 - - - - 1.00 1.00 2 Fb'+ 850 1.15 1.00 1.00 1.000 1.100 - 1.00 1.00 1.00 2 Fcp' 405 - 1.00 1.00 - - - - 1.00 1.00 - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 2 Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D + S Bending(+): LC #2 = D + S Deflection: LC #2 = D + S (live) LC #2 = D + S (total) Bearing : Support 1 – LC #2 = D + S Support 2 – LC #2 = D + S D=dead S=snow All LC's are listed in the Analysis output Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1 CALCULATIONS: V max = 2111, V design = 1709 lbs; M(+) = 5542 lbs-ft EIy = 539.86 lb-in^2 "Live" deflection is due to all non-dead loads (live, wind, snow…) Total deflection = 1.5 dead + "live" Design Notes: 1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 9 10 COMPANY June 10, 2022 08:53 PROJECT RJ1.wwb Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Load1 Dead Full Area No 8.00(24.0") psf Load2 Snow Full Area Yes 25.00(24.0") psf Self-weight Dead Full UDL No 1.7 plf Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 10.957' 10.167'1.667'0' Unfactored: Dead 115 79 Snow 303 210 Factored: Total 418 289 Bearing: F'theta 451 451 Capacity Joist 592 338 Support 586 586 Des ratio Joist 0.71 0.85 Support 0.71 0.49 Load comb #2 #4 Length 0.50* 0.50* Min req'd 0.36** 0.50* Cb 1.75 1.00 Cb min 1.75 1.00 Cb support 1.25 1.25 Fcp sup 625 625 *Minimum bearing length setting used: 1/2" for end supports and 1/2" for interior supports **Minimum bearing length governed by the required width of the supporting member. Lumber-soft, Hem-Fir, No.2, 2x6 (1-1/2"x5-1/2") Supports: All - Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 24.0" c/c; Total length: 11.13'; Clear span(horz): 8.438', 1.625'; Volume = 0.6 cu.ft.; Pitch: -4.75/12 Lateral support: top = continuous, bottom = at supports; Repetitive factor: applied where permitted (refer to online help); This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 46 Fv' = 172 psi fv/Fv' = 0.27 Bending(+) fb = 941 Fb' = 1461 psi fb/Fb' = 0.64 Bending(-) fb = 152 Fb' = 1130 psi fb/Fb' = 0.13 Deflection: Interior Live 0.24 = L/457 0.46 = L/240 in 0.52 Total 0.33 = L/335 0.61 = L/180 in 0.54 Cantil. Live -0.14 = L/149 0.18 = L/120 in 0.80 Total -0.19 = L/111 0.24 = L/90 in 0.81 Additional Data: FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC# Fv' 150 1.15 1.00 1.00 - - - - 1.00 1.00 2 Fb'+ 850 1.15 1.00 1.00 1.000 1.300 - 1.15 1.00 1.00 4 Fb'- 850 1.15 1.00 1.00 0.773 1.300 - 1.15 1.00 1.00 2 Fcp' 405 - 1.00 1.00 - - - - 1.00 1.00 - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 4 Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 4 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D + S Bending(+): LC #4 = D + S (pattern: sS) Bending(-): LC #2 = D + S Deflection: LC #4 = D + S (pattern: sS) (live) LC #4 = D + S (pattern: sS) (total) Bearing : Support 1 – LC #2 = D + S Support 2 – LC #4 = D + S (pattern: sS) D=dead S=snow All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, _=no pattern load in this span Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1 CALCULATIONS: V max = 283, V design = 255 lbs; M(+) = 593 lbs-ft; M(-) = 96 lbs-ft EIy = 27.04 lb-in^2 "Live" deflection is due to all non-dead loads (live, wind, snow…) Total deflection = 1.0 dead + "live" Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 Lateral stability(-): Lu = 9.13' Le = 14.56' RB = 20.7; Lu based on full span Design Notes: 1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. SLOPED BEAMS: level bearing is required for all sloped beams. 11 COMPANY May 26, 2022 15:56 PROJECT RJ2.wwb Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Load1 Dead Full Area 7.00(24.0") psf Load2 Dead Point 4.52 110 lbs Load3 Snow Point 4.52 300 lbs Self-weight Dead Full UDL 2.9 plf Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 14.029' 13'0' Unfactored: Dead 190 156 Snow 196 104 Factored: Total 386 260 Bearing: F'theta 449 449 Capacity Joist 386 337 Support 672 586 Des ratio Joist 1.00 0.77 Support 0.58 0.44 Load comb #2 #2 Length 0.57 0.50* Min req'd 0.57 0.50* Cb 1.00 1.00 Cb min 1.00 1.00 Cb support 1.25 1.25 Fcp sup 625 625 *Minimum bearing length setting used: 1/2" for end supports Lumber-soft, Hem-Fir, No.2, 2x10 (1-1/2"x9-1/4") Supports: All - Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 24.0" c/c; Total length: 14.31'; Clear span(horz): 12.938'; Volume = 1.4 cu.ft.; Pitch: -4.75/12 Lateral support: top = continuous, bottom = at supports; Repetitive factor: applied where permitted (refer to online help); This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 37 Fv' = 172 psi fv/Fv' = 0.22 Bending(+) fb = 871 Fb' = 1237 psi fb/Fb' = 0.70 Live Defl'n 0.19 = L/893 0.70 = L/240 in 0.27 Total Defl'n 0.36 = L/465 0.93 = L/180 in 0.39 Additional Data: FACTORS: F/E(psi) CD CM Ct CL CF Cfu Cr Cfrt Ci LC# Fv' 150 1.15 1.00 1.00 - - - - 1.00 1.00 2 Fb'+ 850 1.15 1.00 1.00 1.000 1.100 - 1.15 1.00 1.00 2 Fcp' 405 - 1.00 1.00 - - - - 1.00 1.00 - E' 1.3 million 1.00 1.00 - - - - 1.00 1.00 2 Emin' 0.47 million 1.00 1.00 - - - - 1.00 1.00 2 CRITICAL LOAD COMBINATIONS: Shear : LC #2 = D + S Bending(+): LC #2 = D + S Deflection: LC #2 = D + S (live) LC #2 = D + S (total) Bearing : Support 1 – LC #2 = D + S Support 2 – LC #2 = D + S D=dead S=snow All LC's are listed in the Analysis output Load combinations: ASD Basic from ASCE 7-16 2.4 / IBC 2018 1605.3.1 CALCULATIONS: V max = 359, V design = 346 lbs; M(+) = 1553 lbs-ft EIy = 128.61 lb-in^2 "Live" deflection is due to all non-dead loads (live, wind, snow…) Total deflection = 1.0 dead + "live" Bearing: Allowable bearing at an angle F'theta calculated for each support as per NDS 3.10.3 Design Notes: 1. Analysis and design are in accordance with the ICC International Building Code (IBC 2018) and the National Design Specification (NDS 2018), using Allowable Stress Design (ASD). Design values are from the NDS Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 4. SLOPED BEAMS: level bearing is required for all sloped beams. 12 6 7 8 9 10 11 12 13 14 15 16 (2) 2x4 HF Stud 5,149 4,121 3,311 2,693 2,224 1,862 1,579 1,355 1,175 1,028 906 PSILL 4,784 - - - - - - - - - - (3) 2x4 HF Stud 9,220 7,723 6,382 5,281 4,406 3,715 3,166 2,726 2,369 2,076 1,834 PSILL 6,910 6,910 -- - - - - - - - (4) 2x4 HF Stud 12,294 10,298 8,510 7,041 5,875 4,953 4,221 3,635 3,159 2,769 2,445 PSILL 8,505 8,505 8,505 - - - - - - - - (2) 3x4 HF Stud 10,245 8,581 7,091 5,868 4,896 4,128 3,518 3,029 2,632 2,307 2,038 PSILL 7,619 7,619 -- - - - - - - - (3) 3x4 HF Stud 15,367 12,872 10,637 8,802 7,343 6,191 5,277 4,543 3,948 3,461 3,057 PSILL 10,631 10,631 10,631 - - - - - - - - (2) 2x6 HF Stud 7,951 6,405 5,164 4,210 3,481 2,917 2,476 2,125 1,843 1,613 1,423 PSILL 7,518 - - - - - - - - - - (3) 2x6 HF Stud 16,730 15,297 13,636 11,927 10,333 8,934 7,746 6,750 5,918 5,221 4,634 PSILL 10,859 10,859 10,859 10,859 -- - - - - - (4) 2x6 HF Stud 23,902 22,755 21,314 19,614 17,764 15,903 14,146 12,558 11,158 9,942 8,891 PSILL 13,365 13,365 13,365 13,365 13,365 13,365 13,365 - - - - 4x6 HF #2 14,409 11,327 9,009 7,286 5,993 5,006 4,239 3,633 3,147 2,751 2,425 PSILL 8,328 8,328 8,328 - - - - - - - - 4x8 HF #2 18,744 14,808 11,809 9,566 7,876 6,583 5,577 4,782 4,142 3,622 3,193 PSILL 10,277 10,277 10,277 - - - - - - - - 4x10 HF #2 23,562 18,717 14,972 12,150 10,015 8,377 7,101 6,090 5,277 4,615 4,069 PSILL 13,112 13,112 13,112 - - - - - - - - 6x6 DF #2 19,595 18,889 17,995 16,908 15,659 14,315 12,960 11,665 10,475 9,407 8,463 PSILL 13,087 13,087 13,087 13,087 13,087 13,087 -- - - - 6x8 DF #2 25,830 24,899 23,721 22,288 20,642 18,870 17,083 15,377 13,808 12,400 11,156 PSILL 16,149 16,149 16,149 16,149 16,149 16,149 16,149 - - - - 6x10 DF #2 28,621 27,790 26,739 25,450 23,929 22,224 20,420 18,614 16,885 15,285 13,835 PSILL 20,604 20,604 20,604 20,604 20,604 20,604 - - - - - Description By BTJ Date 06/10/22 Checked Date Scale Sheet No. Project Job No.Wilkie Residence 22145.10 HF Column & HF Sill Plate Capacity TABLE IBC 2018, NDS 2018 Date modified 10-2-14 Wood Column Capacity Table 250 4th Ave. South Suite 200 13 14