Loading...
BLD2023-0800+Manufacturer_Specifications_and_Installation_Instructions+6.28.2023_8.35.58_AM+3636456S HEATING & AIR CONDITIONING Submittal Side Discharge Variable Speed HP RECEIVED Jun 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2023-0800 For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after order. 4A6L9036A1000B Epoxy Coated Model 4A6L9036A1 COTB Note: "Graphics in this document are for representation only. Actual model may differ in appearance. " October2021 4A61-9036A-SUB-1 D-EN Aw�c*" SAWdard® HEATING & AIR CONDITIONING Product Specifications OUTDOOR UNIT (a) (b) 4A6L9036A1XXXB POWER CONNS. — V/PH/HZ (c) 208-230/1/60 MIN. BRCH. CIR. AMPACITY 26.9 BR. CIR. PROT. RTG. — MAX. (AMPS) 30 COMPRESSOR DURATION@- SCROLL NO. USED — NO. STAGES 1 —Variable VOLTS/PH/HZ 208-230/1/60 R.L. AMPS (d) — L.R. AMPS 12.4 / 48.9 FACTORY INSTALLED START COMPONENTS (e) NO INSULATION/SOUND BLANKET YES SUMP HEAT YES OUTDOOR FAN PROPELLER DIA. (IN.) — NO. USED 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— VARIABLE CFM @ 0.0IN. W.G. M 2400 NO. MOTORS — HP 1-1/2 MOTOR SPEED R.P.M. 200-1050 VOLTS/PH/HZ 325-385 VDC/3/60 F.L. AMPS 2.3 OUTDOOR COIL — TYPE PLATE FIN ROWS—F.P.I. 2-16 FACE AREA (SQ. FT.) 12.88 TUBE SIZE (IN.) 5/16 REFRIGERANT LBS. — R-410A (O.D. UNIT) (g) 8 LBS, 0 OZ FACTORY SUPPLIED YES LINE SIZE — IN. O.D. GAS (h) 3/4 LINE SIZE — IN. O.D. LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING COOLING MODE 10° F DIMENSIONS H X W X D CRATED (IN.) 42 x 56 x 24 UNCRATED (IN.) 36-3/4 X 47 X 17-1/2 WEIGHT SHIPPING (LBS.) 250 NET (LBS.) 226 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 275. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. Optional kit shown. (f) Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Reference the outdoor unit ship -with literature for refrigerant piping length and lift guidelines. Reference the refrigerant piping software pub # 32-3312-xx or refrigerant piping application guide SS- APG006-xx for long line sets or specialty applications (xx denotes latest revision). Center Mass Dimensions 40.25' „BA 'A� W2 W1 Model 2 Ton 3 Ton 4/5 Ton Total Weight 206 228 247 W1(LB) 135.63 143.03 150.35 Dim"A" 13.75 15.00 15.75 W2 (LB) 70.37 84.97 96.65 Dim"B" 26.50 25.25 24.50 4A6L9036A-SUB-1 D-EN �c icati, �S'7 iw HEATING & AIR CONDITIONING Outline Drawing SNOULO OE AT LEAST ISt.1 I6 INCNESI FROM WALL AND 609.6 (2 FEETI FAON SUAROUNOI NG SNAUUOERY ON ALL SIDES. IOU ID LINE SEAVICE VALVE, I.D. fEMALE BRAZE CONNECTION WI TN Ile• SAE f LAAE PRESST TAP FITTINGS. PANEL J + H+ T GAS LINE Ill TURN BALL SERVICE VALVE, V I.D. FEMALE BRAZED CONNECTION WITN Ill' SAE G iLAflE PflESSUAE TAP FIiiIN6. FIGURE 2 ACCESS PANfL* 11 GAS LINE SERVICE VALVE. _ D I.O. fENALE BRAZED COxNEfiI ON xl iN IZA• SA[ FLAP[ PRESSURE TAP FITTING. FIGURE I Model Base A B C D E F G H J K 4A6L9036A 4.3 934 1194 445 16 10 (54 / 159 101 (3-31/ 187 495 (36-3/4) (47) (17-1/2) (3/4) (3/8) 16) (6-1/4) 32) (7-11/32) (19-1/2) 4A6 L9036A-SUB-1 D-E N 3 �c icati, �S7 iw HEATING & AIR CONDITIONING Sound Pressure Level Outdoor Unit F 3' ft 5' ft Table 1. 3.0 Ton Heating Reflective Surface (Back wall) Sound Pressure Level dB(A) per ARI 275 (Max Heating) # Reflective Surfaces 3' from Property Line S' from Property Line 7' from Property Line 0 46 41 1 490) 44 2 52 47 44 0) Lab tested as per the illustration shown above Table 2. 3.0 Ton Cooling Sound Pressure Level dB(A) per ARI 275 (Max Cooling) # Reflective Surfaces 3' from Property Line 5' from Property Line 7' from Property Line 0 45 1 48(a) 43 2 51 46 43 (a) Lab tested as per the illustration shown above Notes: 4A6L9036A1 Sound Characteristics • Measuring place: Hemi-Anechoic chamber Gaoling Heating • Sound pressure level will vary depending on a range of factors such as the construction ° of the particular room where the equipment is installed. 7t i • Operation sound level may differ depending 2 on operation and ambient conditions. u f 40 iA so 100 X Demand 4 4A6L9036A-SUB-1 D-E N �cati, �S'7 iw HEATING & AIR CONDITIONING Mechanical Specification Options General The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures from 55° F to 120' F in cooling. From — 10° F to 66° F in heating. Only AHRI approved indoor matches are approved for use with these models. This outdoor unit contains the Accul-inkTm digital communication with 2 wire connection to outdoor and Plug-n-Play set up. Casing Unit is painted with a glossy corrosion resistant finish on all panels. Refrigerant Controls Refrigeration system controls include condenser fan, high and low pressure switches. A factory supplied, field installed filter drier is standard. Compressor Inverter driven scroll compressor with 50 to 100% output capacity. Noise enclosure minimizes sound levels and built in compressor protection will reduce operating speed and current draw to maintain operation while protecting the compressor. Condenser Coil The copper tube, aluminum fin outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected by a wire guard. Low Ambient Cooling As manufactured, this system has built in freeze protection that will allow cooling operation down to 45' F but will reduce capacity or shut down completely to prevent operation under adverse conditions. Comfort Control The 1050/950/850 Control is required and provides Plug-n-Play setup and 3 wire connection. 4A6 L9036A-SUB-1 D-E N ,4tice�ie4W SSfidOrd® HEATING & AIR CONDITIONING About American Standard Heating and Air Conditioning American Standard has been creating comfortable and affordable living environments for more than a century. For more information, please visit www.americanstandardair.com. C UL US LISTED The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 4A6L9036A-SUB-1D-EN 040ct2021 Supersedes 4A6L9036A-SUB-1C-EN (March 2020) ©2021 American Standard Heating and Air Conditioning