Loading...
APPROVED FIR2023-0060+Fire_Sprinkler_Plan+6.9.2023_2.24.21_PM+3600613JOB NUMBERDESIGNERDESIGNER JOB NUMBER EDMONDS OWNER / ARCHITECT Key Plan MOLLY MOON @ MAIN ST COMMONS Drawing Title 06.09.2023 05043C Date: FP1.10 NICET Stamp Approvals Required WILCOX CONSTRUCTION 550 MAIN ST EDMONDS, WA 98020 Contract With: BRYAN FARMERDesigner: Revisions 234 5TH AVE S EDMONDS, WA 98020 SUPER: TOM NESS Phone: 206-817-1308 Fax: TENANT IMPROVEMENT SPRINKLER PLAN Contract Name: Building Permit: Job Number: Drawing No. NORTHWEST FIRE SYSTEMS Ph: 206.772.7502 * Fax: 206.772.7504 22645 83rd ave. S., Bldg D *Kent, WA 98032 www.nwfiresystems.com LIC # NORTHFS928CR ORDINARY HAZARD II PAINTING OR LABELING OF PIPE AND/OR EQUIPMENT ELECTRICAL WIRING OF ANY KIND INCLUDING BUT NOT LIMITED TO WATERFLOW SWITCH, ELECTRIC BELL, AND TAMPER SWITCHES CENTRAL STATION MONITORING EQUIPMENT, WIRING AND SERVICES ALL UNDERGROUND WORK INCLUDING BUT NOT LIMITED TO: BACKFILL, SELECT FILL, BREAKING PATCHING, SAW CUTTING, LAWN REPAIR, LANDSCAPING, TREE REMOVAL, STERILIZATION, DEVELOPMENT FEES AND CITY CONNECTION. EXISTING SYSTEM DESIGN CRITERIA (WET) NORTHWEST FIRE SYSTEMS (NWFS) TO MODIFY EXISTING WET PIPE AUTOMATIC SPRINKLER SYSTEM TO ACCOMMODATE FOR NEW WALLS AND CEILING NWFS WILL START WORK AT A THE OVER HEAD SYSTEM. ALL AREAS PROTECTED BY A WET SYSTEM MUST BE MAINTAINED BY OTHERS AT A MINIMUM 40°F TO PREVENT FREEZING. EXCLUSIONS DESIGN DENSITY: 0.20 gpm/ft² OVER 1500ft² PER NFPA 13(2016) AND CITY OF EDMONDS MERCANTILE NO NEW HYDRAULIC CALCULATIONS WERE PERFORMED. ALTERATIONS TO SYSTEM DO NOT AFFECT HYDRUALIC PERFORMANCE DESIGN DENSITY: 0.15 gpm/ft² OVER 1500ft² RESTAURANT/ KITCHEN PREP AREA NEW T.I. DESIGN CRITERA ORDINARY HAZARD I SCOPE OF WORK DESIGN CRITERIA SNATR GROOVED 45° ELL VERTICAL OFFSET X-X TS CENTERLINE RISER NIPPLE O.C. BALL VALVE TYPICAL MT EXISTING SPRINKLER PIPING L PIPE DOWN MAIN PIPE DESIGNATION LABEL CENTERLINE OF PIPE TO BOTTOM OF DECK CUT TO SUIT GALVANIZED TYP UNO PIPE UP FLOW SWITCH (FS) PIPE HANGER NEW SPRINKLER PIPING HOSE VALVE ABBREVIATIONS UNLESS NOTED OTHERWISE POL # THREAD GROOVED ELL (LOOKING SIDEWAYS) DN IFOW FIRE DEPT. CONNECTION SWAY BRACING LINE PIPE DESIGNATION LABEL GAL RN INSIDE FACE OF WALL X-X FF X-X BB SYMBOLS PIPE-O-LET CTS THR FDC CENTERLINE OF PIPE TO BOTTOM OF BEAM OR JOIST RC ALL-THREAD RODSB-?DROP HYDRAULIC NODE UP C REDUCING COUPLING THREADED PIPE VERTICAL OFFSET FLEXIBLE COUPLING GROOVED 45° ELL LATERAL OFFSET RIGID COUPLING GROOVED ELL (LOOKING DOWN) BRANCHLINE RESTRAINT CENTERLINE OF PIPE ABOVE FINISHED FLOOR DR STAINLESS STEEL BUTTERFLY VALVE CHECK VALVE SPRINKLER PLAN SYMBOLS SS RDXX MECHANICAL TEE 11 D ON CENTER GROOVED SHAPED NIPPLE VICINITY MAP RED RED 06 / 0 9 / 2 0 2 3 Byron Richard Moye 9419-0815-C Level 3 Northwest Fire Systems, LLC NORTHFS928CR 558 Suite 104 RECEIVED Jun 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FIR2023-0060 06-16-2023 PLAN REVIEW NOTES: APPROVED DFM BURT Approved DFM Chris Burt South County Fire Date: 06/16/2023