Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2023-0060+Fire_Sprinkler_Equipment_Specification_Sheets+6.9.2023_2.24.36_PM+3600615
RECEIVED Jun 13 2023 CITY OF EDMONDS DEVELOPMENT SER' DEPARTMENT FI R2023-0060 NOR TNWES T FIRE SYSTEMS 2545 83,d Ave. ., Bldg D * Cent, WA 98032 Ph: 206.772.7502 * Fax; 206.772.7504 Www.nwfiresysterns.corn LIC # NORTHF59 8CR EQUIPMENT SUBMITTAL Molly Moon Edmonds, WA NWSF JOB NO. 05043C tqC00 Series TY-FRB - Worldwide I www.tyco-fire.com Contacts 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent Quick Response, IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfpl71 General Description The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described in herein are quick response, standard coverage, decorative 3 mm glass bulb -type spray sprinklers. They are designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. The sprinkler, where applicable, is intended for use in areas with a finished and Recessed Pendent Sprinklers Standard Coverage ceiling. This recessed pendent sprin- kler uses one of the following recessed escutcheons: • Two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon with 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. • Two-piece Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) Recessed Escutcheon with 1/4 in. (6,4 mm) of recessed adjustment or up to 1/2 in. (12,7 mm) of total adjustment from the flush pendent position. The adjustment provided by the recessed escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion -resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed to corrosive atmospheres. Although corrosion -resistant coated sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corrosive environment. The effects of ambient temperature, con- centration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-FRB Pendent Sprinklers is detailed in technical data sheet TFP356. Sprinkler guards are detailed in technical data sheet TFP780. NO CITNO E The Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. NFPA 13 prohibits installation of 112 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. Sprinkler Identification Number (SIN) TY1131 ... Upright 2.8K, 1/2 in. NPT TY1231 .. Pendent 2.8K, 1/2 in. NPT TY2131 ... Upright 4.2K, 1/2 in. NPT TY2231 .. Pendent 4.2K, 1/2 in. NPT TY3131 ... Upright 5.6K, 1/2 in. NPT TY3231 .. Pendent 5.6K, 1/2 in. NPT TY4131 ... Upright 8.OK, 3/4 in. NPT TY4231 .. Pendent 8.OK, 3/4 in. NPT TY4831 ... Upright 8.OK, 1/2 in. NPT TY4931 .. Pendent 8.OK, 1/2 in. NPT Page 1 of 12 DECEMBER 2022 TFP171 TFP171 Page 2 of 12 * Temperature rating ** Pipe thread connections per 1 - Frame is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Deflector. special request. PLATE SEATING SURFACE 7/16" (11,1 mm) NOMINAL 2-1/4" MAKE -IN (57,2 mm) l2-3/16" (55,6 mm) I 1/2" NPT** WRENCH STYLE 10 or 20 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 3 - Sealing 5 Compression Assembly Screw 4 - Bulb 6 Deflector* 7 Bushing 2-7/8" (73,0 mm) DIA. - RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY1131) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 112 IN. NPT * Temperature rating is indicated on Deflector. 7/16" (11,1 mm NOMINAL MAKE -IN 2 (5 1/2' NPT** UPRIGHT ** Pipe thread connections per ISO 7-1 can be provided on special request. ESCUTCHEON PLATE SEATING SURFACE 5 PENDENT ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* 2-7/8" (73,0 mm) DIA. - :1-[�3��y��7��1►1�7�1►�1 3 2 4 - 5 6* CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 IN. NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and NYC Approved EAC Approved Note: For complete approval information, including corrosion -resistant status, see Tables A, B, C and D. Maximum Working Pressure See Table E Discharge Coefficient K=2.8 gpm/psi'/2 (40,3 Lpm/bars) K=4.2 gpm/psi'/2 (60,5 Lpm/bars) K=5.6 gpm/psi'/2 (80,6 Lpm/bars) K=8.0 gpm/psi/2 (115,2 Lpm/bars) Temperature Rating See Tables A and B Finishes Sprinkler: See Table D Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ...................... Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw ................. Bronze Deflector ................... Copper/Bronze Bushing(K=2.8).....................Bronze Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the style 10, 20, 30, or 40 recessed escutcheon, as applica- ble, for recessed pendent installations. TFP171 Page 3 of 12 * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2" NPT* UPRIGHT 7/16" :11,1 mm) NOMINAL 2/16 MAKE -IN mm" ) 2-3/16" 1-1 (55,6 mm) (38,11 mm) * WRENCH STYLE 10 or 20 FLATS RECESSED PENDENT ESCUTCHEON 2-7/8" (73,0 mm) DIA. - RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 112 IN. NPT * Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2" (12,7 mm) NOMINAL 2-5/16" MAKE -IN (58,7 mm) 2-1/4" 1-9/16" (57,2 mm) (39,7 mm) 3/4" NPT** WRENCH STYLE 30 or 40 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON 2-7/8" (73,0 mm) DIA. — RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 IN. NPT 7/16" (11,1 mm) NOMINAL Ll MAKE -IN mi,16" I' (55,6 mm) i 1/2" NPT** WRENCH FLATS UPRIGHT PENDENT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw 1 3 - Sealing 6 -Deflector Assembly 3 4 - Bulb 2-1/4" 1 (57,2 mm)Y6* 2 I* Temperature rating is 1-9/16"4 indicated on Deflector. (39,7 mm) 5 ** Pipe thread connections per ISO 7-1 can be a provided on special request. CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 112 IN. NPT TFP171 Page 4 of 12 Installation The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak -tight 1/2 in. NPT sprinkler joint should be obtained by applying a mini- mum -to -maximum torque of 7 ft-lb to 14 ft-lb (9,5 N•m to 19,0 N•m). A leak tight 3/4 in. NPT sprinkler joint should be obtained with a torque of 10 ft-lb to 20 ft-lb (13,4 N•m to 26,8 N•m). Higher levels of torque can distort the sprinkler inlet and cause leakage or impairment of the sprin- kler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under or over -tightening the sprinkler. Re -adjust the position of the sprinkler fitting to suit. Series TY-FRB Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand - tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench as shown in Figure 14. Apply the sprinkler wrench to the sprinkler wrench flats as shown in Figure 1 to Figure 5. Series TY-FRB Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10, 20, 30, or 40 Mounting Plate, as applica- ble, over the sprinkler threads and with pipe -thread sealant applied to the pipe threads, hand -tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench as shown in Figure 15. Apply the sprinkler wrench to the sprinkler wrench flats as shown in Figure 1 to 4. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10, 20, 30, or 40 closure over the Series TY-FRB Recessed Pendent Sprinkler and push the closure over the mounting plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire pro- tection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be taken to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. For more information, see Installation section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or sprinkler manufac- turer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. For more informa- tion, see Installation section. Initial and frequent visual inspections of random samples are recommended for corrosion -resistant sprinklers to verify the integrity of the corrosion -resistant material of construction. Thereafter, annual inspections according to NFPA 25 should suffice. Inspections of cor- rosion -resistant sprinklers are recom- mended at close range, instead of from the floor level per NFPA. Inspection at close range can better determine the exact sprinkler condition and the long- term integrity of the corrosion -resistant material, which can be affected by the corrosive conditions present. TFP171 Page 5 of 12 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" 4L(3,2 mm) i MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 IN. NPT 5/8±1 /4" (15,9±6,4 mm) FACE OF SPRINKLER FITTING MOUNTING SURFACE 2-7/8" DIA. (73,0 mm) 3/4" (19,1 mm) 2-1/4" DIA. 1/4" (6,4 mm) (57,2 mm) MOUNTING ,- PLATE CLOSURE SERIES TY-FRB 1/8" (3,2 mm) j 14L 1-1/4" (31,8 mm) 3/4" (19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 IN. NPT 2-7/8" DIA. (73,0 mm) 1/2" 12,7 mm (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) (FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1 1/8" 1 (3,2 mm) MOUNTING SURFACE 7 CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 IN. NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) MOUNTING SURFACE 1 1-1/4" (31,8 mm) CLOSURE SERIES TY-FRB 1" (25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 IN. NPT TFP171 Page 6 of 12 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING (SPRINKLER r / PLATE FITTING (3,2 mm) j i ------------------ MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 3/4" (19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 IN. NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 IN. NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH 2-7/8" DIA. (73,0 mm) 1/2" 12,7 mm (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-1/4" (31,8 mm) TY-FRB 1 " (25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 IN. NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 IN. NPT WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP171 Page 7 of 12 Sprinkler Finish5 K-Factor Type Temperature Bulb Liquid Color Natural Brass Chrome Plated F Polyesters 135°F(57°C) Orange 155°F (68°C) Red Pendent (TY1231) 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1, 2, 3, 4 135°F (57°C) Orange 155°F (68°C) Red Upright (TY1131) 175°F (79°C) Yellow 200°F (93°C) Green 2.8 1/2 in. NPT 286°F (141°C) Blue 135°F(57°C) Orange Recessed Pendent ° ° 155F 68C ( ) Red (TY1231)a Figure 6 175°F (79°C) Yellow 200°F (93°C) Green 1,2,4 135°F(57°C) Orange Recessed Pendent ° ° 155F 68C ( ) Red (TY1231)b Figure 7 175°F (79°C) Yellow 200°F (93°C) Green NOTES a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion -resistant sprinklers. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 K-FACTOR SPRINKLERS TFP171 Page 8 of 12 Sprinkler Finish3 K-Factor Type Temperature Bulb Liquid Color Natural Brass Chrome Plated Polyester 135°F(57°C) Orange 155°F (68°C) Red Pendent (TY2231) 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Upright (TY2131) 175°F (79°C) Yellow 200°F (93°C) Green 4.2 1/2 in. NPT 1,2 286°F (141°C) Blue 135°F (57°C) Orange Recessed Pendent 155°F(68°C) Red (TY2231)a Figure 8 175°F (79°C) Yellow 200°F (93°C) Green 135°F (57°C) Orange pendent 155°F (68°C) Red 175°F (79°C) Yellow (TY2231)b Figure 9 200°F (93°C) Green NOTES a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion -resistant sprinklers. TABLE B LABORATORY LISTINGS AND APPROVALS FOR 4.2 K-FACTOR SPRINKLERS TFP171 Page 9 of 12 Sprinkler Finish$ K-Factor Type Temperature Bulb Liquid Color Natural Brass Chrome Plated Polyesters Lead Coated 135°F(57°C) Orange 155°F (68°C) Red Pendent (TY3231) 1, 2, 3, 4, 5, 6, 7 1, 2, 3, 5, 7 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 135°F(57°C) Orange 155°F (68°C) Red Upright (TY3131) 1, 2, 3, 5, 6, 7 1, 2, 3, 5, 7 175°F (79°C) Yellow 200°F (93°C) Green 5.6 286-F(141°C) Blue 1/2 in. NPT 135°F (57°C) Orange 155°F(68°C) Red Recessed Pendent (TY3231)a 1, 2, 4, 5, 7 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green Figure 10 286°F (141°C) Blue 135°F(57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3231)b 1, 2, 3, 4, 5, 7 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 11 286-F(141°C) Blue NOTES a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. d. Not available (N/A). 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. Note the following exceptions: • LPCB does not rate the thermal sensitivity of recessed sprinklers. • The recessed pendent (TY3231) sprinklers with a 286°F (141°C) temperature rating are not LPCB Approved. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. EAC Approved. 8. Where Polyester Coated and Lead -Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion -Resistant Sprinklers. Where Lead -Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion -Resistant Sprinklers. TABLE C LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS TFP171 Page 10 of 12 Sprinkler Finish9 K-Factor Type Temperature Bulb Liquid Color Natural Brass Chrome Plated Polyesters Lead Coated 135°F(57°C) Orange 155°F (68°C) Red Pendent (TY4231) 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue 1, 2, 3, 4, 5, 6, 7, 8 1, 2, 5, 8 135°F (57°C) Orange 155°F (68°C) Red Upright (TY4131) 175°F (79°C) Yellow 200°F (93°C) Green 8.0 286°F (141°C) Blue 3/4 in. NPT 135°F (57°C) Orange 155°F(68°C) Red Recessed Pendent (TY4231)a 1, 2, 5, 8 N/Ad 175°F (79°C) Yellow 200°F (93°C) Green Figure 12 286°F (141°C) Blue 135°F(57°C) Orange 155°F(68°C) Red Recessed Pendent (TY4231)b 1, 2, 3, 5, 8 N/A 175°F ( ) 79°C Yellow 200°F (93°C) Green Figure 13 286°F (141°C) Blue 135°F(57°C) Orange 155°F (68°C) Red Pendent (TY4931) 175°F (79°C) Yellow 200°F (93°C) Green 8.0 1/2 in. NPT 1,2,4,5,6,8 1,2,5,8 286°F (141°C) Blue 135°F (57°C) Orange 155°F (68°C) Red Upright (TY4831) 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue NOTES a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable. b. Installed with Style 20 (1/2 in. NPT) or Style 30 (3/4 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. c. Frame and Deflector only. d. Not available (N/A). 1. Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers. However, _PCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. 8. EAC Approved. 9. Where Polyester Coated and Lead -Coated Sprinklers are noted to be ILL and C-UL Listed, the sprinklers are ILL and C-UL Listed as Corrosion -Resistant Sprinklers. Where Lead -Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion -Resistant Sprinklers. TABLE D LABORATORY LISTINGS AND APPROVALS FOR 8.0 K-FACTOR SPRINKLERS TFP171 Page 11 of 12 Sprinkler Finish K-Factor Type Natural Chrome Polyester Lead Coated Brass Plated Pendent (TY1231) and 2.8 Upright (TY1131) 1/2 in. 175 psi (12,1 bar) N/A2 NPT Recessed Pendent (TY1231) Pendent (TY2231) and 4.2 Upright (TY2131) 1/2 in. 175 psi (12,1 bar) N/A Recessed NPT Pendent (TY2231) Pendent (TY3231) and 5.6 1/2 in. Upright (TY3131) 250 psi (17,2 bar) NPT or 175 psi (12,1 bar)t Recessed Pendent (TY3231) Pendent (TY4231) 175 psi 8.0 and Upright (TY4131) (12,1 bar) 3/4 in. 175 psi (12,1 bar) Recessed N/A NPT Pendent(TY4231) 8.0 Pendent (TY4931) 175 psi 1/2 in. and 175 psi (12,1 bar) (12,1 bar) NPT Upright (TY4831) NOTES 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. 2. Not available (N/A). TABLE E MAXIMUM WORKING PRESSURE TFP171 Page 12 of 12 P/N 57 - XXX - X - XXX SIN 330 2.8K UPRIGHT (1/2 in. NPT) TY1131 331 2.8K PENDENT (1/2 in. NPT) TY1231 340 4.2K UPRIGHT (1/2 in. NPT) TY2131 341 4.2K PENDENT (1/2 in. NPT) TY2231 370 5.6K UPRIGHT (1/2 in. NPT) TY3131 371 5.6K PENDENT (112 in. NPT) TY3231 390 8.OK UPRIGHT (3/4 in. NPT) TY4131 391 8.OK PENDENT (3/4 in. NPT) TY4231 360 8.OK UPRIGHT (1/2 in. NPT) TY4831 361 8.OK PENDENT (1/2 in. NPT) TY4931 SPRINKLER TEMPERATURE FINISH 135 155 175 200 286 RATINGS 1 NATURAL BRASS 135°F (57°C) 3 PURE WHITE 1 POLYESTER (RAL9010) 155°F (68°C) 4 SIGNAL WHITE POLYESTER (RAL9003) °F79°C 175 ( ) 5 JET BLACK 2 POLYESTER (RAL9005) 200°F (93°C) 7 LEAD COATED 286°F (141°C) 9 CHROME PLATED NOTES 1. Eastern Hemisphere sales only. 2. Available in only 2.8K, 4.21K, and 8.OK, 155°F (68°C) and 200°F (93°C); requires longer lead time to manufacture. TABLE F SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright) Sprinkler (specify) temperature rating, (specify) finish or coating, P/N (specify from Table F) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish, P/N (specify') Refer to technical data sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 m 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Jol L1nson ORO NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Flre Protection Association; Controls TEFLON Is a trademark of The Chem —Company FC, LLC tqC00 TFP171 Change History Appendix Worldwide I www.tyco-fire.com Contacts ISSUE DATE NOTES Page 9, Table C, added note to footnote 4, removing LPCB Approved from Pendent and Recessed 12-22 Pendent TY3231 286°F (141°C) temperature rating; Page 9, Table C, removed note Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers, formerly footnote 7. Page 1, added QR code and URL to allow convenient access to electronic version from printed doc- ument; Page 2, Approvals sub -section, Page 9, Table C, Page 10, Table D, TY3231, TY4131, TY4231, 09-22 TY3131 sprinkler only, added EAC Approved; Page 12, changed corporate address and telephone number to 1467 Elmwood Avenue, Cranston, RI 02910 1 Telephone +1-401-781-8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700. 12-20 Changed temperature rating of TY4131 8.01K Upright Sprinkler with Blue bulb liquid color to 286°F (141 °C), formerly shown incorrectly as 200°F (93nC). 03-20 Removed LPCB Approval from TY3131 5.6K Upright Sprinkler. Updated Tyco® branding and document format; Added Johnson Controls copyright; Added disclaimer 07-18 stating specifications and information subject to change without notice; Added reference to Regula- tory and Health Warning Technical Data Sheet TFP2300; Added Poly -Stainless Grey Aluminum finish, formerly described in Technical Data Sheet TFP682. 09-17 Added statement prohibiting sprinklers featuring K-factors greater than 5.6 and 1/2 in. NPT thread size from installation in new construction, explicitly for retrofit applications only. 11-15 Clarified finishes and polyester coating. 10-13 Removed Eastern Hemisphere Sales Only limitation from TY4831 and TY4931 upright and pendent 8.OK x 1/2 in. NPT sprinklers; Added torque requirements for 3/4 in. NPT sprinklers. 03-13 Updated and standardized RAIL color finishes. Added higher temperature rating for TY3231 and TY4241; Clarified LPCB certification; Corrected SIN 07-10 numbers in Table C for 2.81K and 4.21K sprinklers; Simplified footnotes in Tables A and B; Clarified Instal- lation and Care and Maintenance sections. 08-07 Added FM Approval for 5.6K White Coated Sprinkler with Style 20 Recessed Escutcheon application. 03-07 Added 8.OK 1/2 in. NPT Pendent and Upright Sprinklers. 04-06 Added statement indicating TY3131 and TY3231 are UL and C-UL Listed for 250 psi (17,2 bar) maximum working pressure. 07-04 Added reference to Installer Warning data sheet TFP700; Added LPCB Reference Numbers; Added option for White RAL9010 for Eastern Hemisphere sales. 04-03 Added 4.21K sprinkler; Added recessed option for 2.81K pendent sprinkler. 01-03 Added new Tyco Fire & Building Products masthead. 09-02 New Technical Data Sheet TFP171 describes Series TY-FRB Upright, Pendent, and Recessed Pendent Sprinklers. 1467 Elmwood Avenue, Cranston, RI 029101 Telephone +1-401-781-8220 Johnson 01,to © 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Controls Bulletin 157 Rev. J Ill Features 1. The Model F30R sprinkler utilizes Belleville Spring Closure Technology. Reliable is the first in the industry to produce a Quick Response Dry Concealed sprin- kler utilizing this technology. 2. Styles available • Pendent • Recessed FP Pendent • Recessed F1 Pendent • Concealed • Horizontal Sidewall • Recessed FP Horizontal Sidewall • Recessed F1 Horizontal Sidewall 3. 11/2" (38mm) escutcheon adjustment on pendent sprinkler. 4. 1/2" (13mm) escutcheon adjustment on recessed sprin- kler with push -on/ thread -off FP Model Escutcheon ring. 5. 3/8" (9.5mm) cover plate adjustment on concealed sprinkler with push -on/ thread -off CCP Cover Plate. 6. 3/4" (19mm) escutcheon adjustment on recessed sprinkler with F1 Escutcheon. 7. Attractive appearance. Employs 3mm frangible glass bulb and galvanized nipple. 8. Lengths available to accommodate installation di- mensions from 2" - to - 48" (51 mm - to - 1219mm), in '/4" (6mm) increments. See specific styles for correct "A" dimension range. 9. Available in a variety of plated and painted finishes. 10. Polyester Coated or Electroless Nickel PTFE (Teflon°)* Plated Corrosion Resistant Sprinklers. *Concealed Sprinkler is not corrosion resistance. US Patent Numbers 5,775,431 and 5,967,240. Other US Patents pending. Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Style Response Sprinkler System TvDe Hazard Pendent Recessed Pendent Wet Pipe Light Recessed F1 Pendent Quick Dry Pipe Ordinary CCP Concealed All Preaction R5714 Horizontal Sidewall Wet Pipe Recessed Horizontal Sidewall Quick Dry Pipe Light R5734 All Preaction 2. Certified by FM Approvals Style ty Response p Sprinkler System Type Hazard Pendent Wet Pipe Light Ordinary, Recessed F1 Pendent Quick Dry Pipe Groups (R5714) All Preaction 1&2 Horizontal Sidewall Wet Pipe Recessed F1 Horizontal Sidewall Quick Dry Pipe Light R5734 All Preaction 3. NYC MEA 258-93-E "DuPont Registered Trademark Model F3QR Quick Response Dry Sprinklers A�14 1-0 Pendent (See Fig. 1) Recessed FP Pendent (See Fig. 3) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Concealed (See Fig. 4) Horizontal Sidewall (See Fig. 6) I^ Horizontal Sidewall / HB (See Fig. 7) Recessed F1 Horizontal Sidewall (See Fig. 9) The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR Dry Pendent Sprinkler Model F30R Dry Pendent w/HB Escutcheon "A" Dim. 2" to 48" (51 mm to 1219mm) in %" (6mm) increments "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon®)*j4> Electroless Nickel PTFE (Teflon®) Bronze Brass (3) Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. 4) cULus listed Corrosion Resistant - TJ-�F___�i �- system Tee 1" NPT 2 1/8" Din. Omm] "A" Dimension Hole inCeiling Adjustment Range —1/4" [-6.4mm] 1 43/64" Dia. +1 1/4" [+31.8mm] [42.5mm] 1 1/2" [38.1mm] Total Adjustment Sprinkler Can Ceiling 1 1/4" [31.8mm] 1/4" [6.4mm] Escutcheon Escutcheo n Ceiling Adjustment n1 5/8" Nominal Positian� [41.3mm] of Escutcheon 1/4" [6.4mm] Protrusion 3" Did. [76.2mm] NFW15]FC01 Fig. 1 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides -1/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Sprinkler Guard: Model C-2 Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed FP Pendent Sprinkler "A" Dim. 31/2" to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon6)*(3) Electroless Nickel PTFE (Teflon" )*(4) Bronze Brass Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. Only the escutcheon will contain desired finish. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Cup and Escutcheon Electroless Nickel PTFE (Teflon°)" Plated. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Ratina Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200oF (93°C) 150°F (66°C) Green H' h(1) 286°F 141°C 225°F 107°C Blue Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135°F (57°C) 100°F (38°C) Orange Ordinary 155°F (68°C) 100°F (38°C) Red Intermediate (1) 175°F (79°C) 150°F (66°C) Yellow Intermediate 200°F (93°C) 150°F (66°C) Green Hi h 286°F 141°C 225°F 107°C Blue Listed and Certified only by cULus. Electroless Nickel PTFE (Teflon®)" Plated sprinklers, escutcheons and cups are recommended for exterior applications. System Tee "A" Dimension 2 1/2" [63.5mm] 1" NPT Adjustment Range pia. Hole in Ceiling —1/2" [-12.7mm] 3 1/2" [88.9mm] +1/2" [+12.7mm] Escutheon Di,. Escutheon Adj. Ceiling 1" [25.4] Escutcheon Total Adj. 1/2" [12.7mm] Escutheon Adj. Position Sprinkler Can oNominal f Escutcheon 1-1/4" [31.75mm] 1 Nominal Protrusion 35/8" [41.mm] 2 13/64" [55.88mm] Dia. NEW15]FG02 Fig. 2 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. "I - � System Tee 2 1/2" Dia. [63.50mm] "A" Dimension Hole in Ceiling Adjustment Range 31/4" 2 19/64" Dig. [36.35mm] [58.34mm] Nominal Position of Escutcheon Ceiling 1/4" [6.35mm] Escutcheon Adjustment 1/4" [6.35mm] 3 7/32' Dig. Escutcheon AdjustmentL [81.76mm] 1/2" [12.7mm] Total Adjustment 1" APT Sprinkler Cup Assembly Escutcheon Ceiling NEW157FG03 i Fig. 3 Sprinkler cup and FP Escutcheon fabricated of steel and recommended Note: Do not install the Model F3QR Dry Recessed FP Pendent Sprin- for interior applications. kler in ceilings which have positive pressure in space above. M Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark 2. Model F30R Dry Pendent Concealed Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments ('P (`nvor Plata "' Fini¢hoe 121 Standard Finishes Spec! I Application Finishes Chrome Plated Bright Brass Plated White Black Plated Black Paint Off White Satin Chrome Utilizes the 1/2" cover plate with 3/8" total adjustment. 21 Other finishes and colors are available on special order. Consult factory for details. Standard Temperature Ratings Sprinkler Cover Plate Max. Classification Temperature Temp. Rating Ambient Rating Temp. Ordinary 135oF (57oC) 135-F (57oC) 100-F (38oC) Ordinary 155-F (68-C) 135-F (57oC) 100-F (38oC) Intermediate (1) 175oF (79oC) 165oF (74oC) 150'F (66aC) Intermediate 200-F (93oC) 165-F (74oC) 150-F (66oC) High(') 286aF (141 aC) 165-F (74-C) I 150-F (66aC) Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of brass and recommended for interior applications. (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 Model F3QR Dry Recessed F1 Pendent Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel Electroless Nickel Electroless Nickel PTFE(Teflon®)*(3) PTFE (Teflon")* PTFE (Teflon")* Chrome Chrome Chrome White Polyester (2) White White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100-F (380C) Orange Ordinary 155-F (68-C) 100-F (38oC) Red Intermediate 1 175'F (79'C) 150OF (66aC) Yellow Intermediate 200-F (93oC) 150OF (66aC) Green High (1) 286aF (1410C) I 2250F (107oC) I Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5714 "DuPont Registered Trademark I I;ee i �- System Tee 1" NPT 2 1/2" Dig. [6.35mm] "A" Dimension Hole in Ceiling Adjustment Range f 3/16" 2 19/64" Dig. [t4.76mm] [58.34mm] Nominal Position of Coverplate Sprinkler Cup Assembly Coverplate Ceiling Assembly Ceiling 3/16" [4.76mm] Coverplate Adjustment 3/16" [4.76mm] 3 5/16" Di, Coverplate Adjustment [84.13mm] 3/8" [9.53mm] Total Adjustment NEW157FG04 Fig. 4 Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler in ceilings which have positive pressure in the space above. �---- v- -------2--MF— II 1 I I ly�iiii I �- System Tee 2 1/2" Dig. " NPT [63.50mm] Hole in Ceiling 1 15/16" "A" Dimension [49.2mm] Adjustment Range t 1/4" [t6.35mm] 15/16" Nominal Position [23.8mm] of Escutcheon Sprinkler Cup Assembly Ceiling 1 /8" Ceiling 1 /4" [6.35] 4" Escutcheon Adjustment 4p(� Escutcheon Adjustment Escutcheon 1/2" [12.7mm] Adjustment 2 27/32 NEW157FG05 [72.2mm] Fig. 5 3. Model F3QR Dry Horizontal Sidewall Sprinkle Model F3QR Dry HSW w/HB Escutcheon "A" Dim. 2" to 48" 51 mm to 1219mm in 1/4" 6mm increments "A" Dim. 31/z' to 48" 89mm to 1219mm in 1/4" 6mm increments Finishes"' Sprinkler Escutcheon Electroless Nickel PTFE(Teflon°)"(4) Electroless Nickel PTFE (Teflon(DY Bronze Brass() Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) Not available for HB escutcheons. (4) cULus listed Corrosion Resistant 1 1/2" [38.10mm] Total Adjustment Ceiling r = T 4" [101.60mm] Mir 1 1/4" [31.75mm]a 12" [304.80mm] M Escutcheon Adjustmen System Tee tcheon Adjustment 1" NPT 3/32" .18mm] 3" [76.20m m] 2 1/8" Dia. - [53.98mm] Hole in Wall 1/4" [6.35mm] Sprinkler Can Protrusion "A" Dimension Adjustment Nominal Position Range - 1/4" [-6.35mm] of Escutcheon N£WI57FC06 + 1 1/4 [+31.75mm] Fig. 6 Note: The sprinkler can protrudes 1/4" when escutcheon is in nominal position. Escutcheon adjustment provides '/4" (-6mm) to +11/4" (+32mm) "A" dimension adjustment range. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135OF (57OC) 100°F (38°C) Orange Ordinary 155OF (68OC) 100°F (38°C) Red Intermediate (1) 1750F (790C) 150°F (66°C) Yellow Intermediate 200OF (930C) 150OF (66°C) Green High 2860E 1410C 225°F 107°C Blue (1) Listed and Certified only by cULus. 1" [25.4mm] Total Adjustment Ceiling 1/2" [12.7mml Escutcheon Adjustment 4" [101.60mm] Min. mm 12" [304.80mm] Max. Escutcheon Adjustment 2 3/32" System Tee 3 [53.18mm] 1" NPT 2-13/64" 3-1/2" [55.88mm] [88 9mm] Did. Escutcheon Dia. 2 1/2" Di.. [63.5mm] Hole in Wall 1-1/4" [31.75mm] Nominal Protrusion "A" Dimension Sprinkler Can Escutcheon Adjustment Ncwrnrco� Rongs + 1/2' [+12.7mm] — 1/2" [-12.7mm] Nominal Position of Escutcheon Fig. 7 Note: The sprinkler can protrudes 11/4" when escutcheon is in nomi- nal position. Escutcheon adjustment provides -1/2" (-12.7mm) to +1/2" (+12.7mm) "A" dimension adjustment range. Sprinkler Installation Wrench: Model F3 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Model F30R Dry Recessed FP Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Electroless Nickel PTFE(Teflon11)'(3) Electroless Nickel PTFE (Teflon" )*(4) Bronze Brass Chrome Chrome White Polyester (2) White (1) Other finishes and colors are available on special order. Consult factory for details. Cup remainds unfinished. "See page 2" (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (3) cULus Listed Corrosion Resistant Sprinkler. (4) Sprinkler's can and FP Escutcheon Electroless Nickel PTFE (Teflon®)` Plated recommended for exterior applications. Standard Temperature Ratings Classification Sprinkler Tem- erature Rating Max. Ambient Temp. Bulb Color Ordinary 135°F (57°C) 100°F (380C) Orange Ordinary 155°F (68°C) 100°F (380C) Red Intermediate (1) 175°F (79°C) 150°F (660C) Yellow Intermediate 200OF (93°C) 150OF (660C) Green High 2860E 141°C 2250E 107°C Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 F Ceiling 13/32" Escutcheon [35.7mm] 4" [101.6mm]Min. System Tee Cup 3 12" [304.fimm]Max.'� �1" NIT 3 7/32" Dia. 81.8m_ �m] 2 1/2" Di [63.5mm] = Nominal Position 1 Hole Wall 3 of Escutcheon 2 19/64" Di.. [58.3mm] 1/4" [6.35] Escutcheon Adjustment "A" Dimension Adjustment Range 1 t0 n Adj t NEWtS�FGOB i1/4" Escutcheon Adjustment [36.35mm] Escut1/4" [6.351 cheon Adjustment =k • FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 8 Notes: Do not install the Model F3QR Dry Recessed FP Horizontal Sidewall Sprinkler in walls which have positive pressure in their side space. • Listed by cULus for Quick Response. Approved by FM for Standard Response. • Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. "DuPont Registered Trademark 4. Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler "A" Dim. 31/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Finishes (1) Sprinkler Escutcheon Collar Electroless Nickel Electroless Nickel Electroless Nickel PTFE(Teflon6)"(3) PTFE (Teflon®)` PTFE (Teflon®)" Chrome Chrome Chrome White Polyester (2) White White (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or White. (8) cULus Listed Corrosion Resistant Sprinkler. Standard Temperature Ratings Sprinkler Max. Classification Temperature Ambient Bulb Color Rating Temp. Ordinary 135-F (57oC) 100oF (38oC) Orange Ordinary 155-F (68oC) 100oF (38oC) Red Intermediate (1) 175oF (79oC) 150oF (66oC) Yellow Intermediate 200-F (93oC) 150oF (66oC) Green High (1) 286aF (141aC) 225aF (107aC) Blue (1) Listed and Certified only by cULus. Sprinkler Installation Wrench: Model XL02 Sprinkler Wrench Sprinkler Identification Number (SIN): R5734 Technical Data: Orifice Size:'/z" (15mm) Thread Size: 1" NPT per ANSI B2.1 Working Pressure: 175 psi (12 bar) Nominal K Factor - US / (Metric): 5.6 / (80) Product Description Reliable Model F3QR Dry Sprinklers are quick response sprinklers utilizing a durable 3mm frangible glass bulb. This quick response enables these sprinklers to apply water to a fire much sooner than standard response sprinklers of the similar temperature rating. Model F3QR Dry Sprinklers are intended for use in dry and preac- tion systems and in areas subjected to freezing temperatures, such as freezers and unheated portions inside and outside buildings. Environments wherein dry sprinklers are employed can be cor- rosive. For this reason, Model F3 Sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminents from entering the internal portion of the drop nipple. The wax must not be removed. Operation The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. When the temperature increases sufficiently, due to a fire, the bulb shatters allowing operating parts to clear the waterway. This enables the inlet seal to release air or water and subsequently, cause water flow over the deflector in a uniform spray pattern, controlling or extinguishing the fire. F Ceiling 1 Escutcheon �^1 [3.2mm] �= 4" [101.6mm]Min. System Tee SpAssembly rinkler Cup 1" NPT 3 12" [304.8mm]Max. ref 1 2 27/32" [72.2mm] \\� << 2 1/2" Di �—� [63.5mm] Hole in Wall 31 Nominal Position 1 15/16" [^- of Escutcheon [49.2mm] 1/4" [6.35] Escutcheon Adjustment "A" Dimension 1/2" [12.7mm] NEW157FG09 Adjustment Range Adjustment 31/4" [F6.35mm] 1 [6.35] Escu/4" tcheon Adjustment # • FOR FACTORY MUTUAL (FM) • 4" — 6" FOR UNDERWRITERS LABORATORIES (UL) Fig. 9 Listed by cULus for Quick Response. Approved by FM for Standard Response. Recessed Horizontal sidewall sprinklers are listed with cULus for installation of min. 4" (100mm) - to - max. 6" (150mm) below ceiling and approved by FM for installation of min. 4" (100mm) - to - max. 12" (300mm) below ceiling. Ordering Information Specify: 1. Sprinkler Type select one): (a) Model F3QR Dry Pendent (b) Model F3QR Dry Pendent/HB (c) Model F3QR Dry Recessed FP Pendent (d) Model F3QR Dry Recessed F1 Pendent (e) Model F3QR Dry Concealed Pendent (f) Model F3QR Dry Horizontal Sidewall (g) Model F3QR Dry Horizontal Sidewall/HB (h) Model F30R Dry Recessed FP Horizontal Sidewall (i) Model F30R Dry Recessed F1 Horizontal Sidewall 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Escutcheon type (F1 or FP). 5. Cover Plate/Escutcheon Finish. 6. Length: "A" Dimension (face of tee to face of ceiling or wall) in (6mm) increments. 7. Model F3QR Dry Pendent (a) is available without sprinkler can and escutcheon. Note: 1. The "A" dimension is based on a nominally gauged pipe thread "make-up" of 0.600" (15mm) per ANSI B2.1 [71/2 threads approximately]. 2. All platings and paintings are decorative and intend- ed for interior use. "DuPont Registered Trademark 5. General Installation Instructions Model F3QR dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC*, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The "A" dimension of the dry sprinkler, which extends into the freezers or a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 10. Caution: Do not install Model F3QR Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 11. During installation, the following steps must be followed 1. Cut the specified size hole (see illustrations) for the sprin- kler in the ceiling or wall directly in line with the tee. 2. Apply pipe joint compound to the 1" (25mm) pipe threads and install sprinkler using the Model F3 or XLO2 Sprinkler Wrench as specified. 3. Install the Model FP push -on / thread -off escutcheon or CCP cover plate if required. Note: Installation of the Model F3QR Sprinklers is not rec- ommended in copper pipe systems, as this may reduce the life expectancy of the sprinklers. Model F30R Concealed and Recessed In- stallation Instructions • The Model XLO2 wrench (Fig. 12) is designed to lo- cate on the wrenching pads of the recessed sprin- kler while centering in the cup. A standard'/2" drive ratchet may be used to drive this wrench. Fig. 13 and Fig. 14 show sequentially the insertion of the wrench. First the wrench, with its jaws above the sprinkler de- flector, is moved laterally until centered with the cup. Then raise the wrench inside of the cup until its jaws engage the sprinkler's square wrenching pads (Fig. 14). To remove the wrench, follow this procedure in reverse order. Care should be taken to avoid striking the deflector, with the wrench. • Model F3 Wrench (Fig. 15) is used for installation of Pendent and Horizontal Sidewall sprinklers. • Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the pro- tectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO- TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Maintenance The Model F30R Quick Response Dry Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non - operation. Caution: Use specified by RASCO wrenches only, which are designed to engage sprinkler's wrenching pad. (Fig. 15, page 9) RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DRY PENDENT SPRINKLER SHOWN) AMBIENT TEMPERATURE OF PROTECTED AREA" AT THE DISCHARGE END OF THE SPRINKLER EXPOSED BARREL AMBIENT TEMPERATURE 40'F/4'C I 50'F/101C I 60'F/16'C EXPOSED MINIMUM BARREL LENGTH** (FACE OF TEE TO TOP OF CEILING) IN. MM IN. MM IN. (MM) 40-F (,VC) 0 0 0 30-F (-1'C) 0 0 0 20-F (-TC) 4 (101) 0 0 10-F (-ITC) 8 (203) 1 (25.1) 0 O'F (-IVC) 12 (305) 3 (75) 0 -10'F (-23'C) 14 (356) 4 (101) 1 (25.1) -29F (-29'C) 14 (356) 6 (152) 3 (75) -30'F (-34'C) 16 (406) 8 (203) 4 (101) -40'F (-40'C) 18 (457) 8 (203) 4 (101) -50-F (-46'C) 20 (508) 10 (254) 6 (152) -60-F (-51'C) 20 (508) 10 (254) 6 (152) WET _JIWL1__L__ I 1 MINIMUM OSED (HEATED AREA) EXP BARREL LENGTH i 'A' CLEARANCE DIMENSION HOLE x I • THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. I THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE END OF THE SPRINKLER. FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES USTED, USE THE NEXT COOLER TEMPERATURE. -THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. NOTE: EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH CEILING WIND VELOCITIES IN THE PROTECTED AREA (PROTECTED AREA) INSTALL 1 INCH NPI THREADED END OF DRY PENDENT SPRINKLER INTO THE 1 INCH NPI SIDE OUTLET OF A MALLEABLE IRON TEE FITTING PER ANSI B 16.3 CLASS 150) OR CAST IRON THREADED TEE FITTING PER ANSI 16.4 (CLASS 125) ONLY. IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT. SEAL THE CLEARANCE SPACE AROUND THE SPRINKLER TO AVOID LEAKAGE OF AIR INTO THE PROTECTED AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION. SEE BELOW FOR RECOMMENDED METHODS. ESCUTCHEON 1-3" DIA�I *RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS* RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PIPE 1 VIA-7-1 1i L j L J (HEATED AREA) (HEATED AREA) MINIMUM MINIMUM EXPOSED EXPOSED BARREL 1 BARREL LENGTH DECKTITE FLASHING _j INSIDE FACE SEAL LENGTH (SEE ABOVE) RASCO #4003910 I (SEE ABOVE) (RECOMMENDED) 1 CLEARANCE HOLE 1 INSULATED FREEZER 1 I OR COOLER STRUCTU4RE .......... . .::'. .'.:'. .'. I '.': .':.':.'::.':.'::.':.': .' OR EXTERIOR FRAMIN ...................... , ................... (PROTECTED AREA) III I� A DRY SPRINKLER V f�1:1 /IV IN COLD AREA Fig. 10 7. (PROTECTED AREA) DRY SPRINKLER IN COLD AREA NEW157FG10 *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO OBSTRUCTION INTERNAL OBSTRUCTION FEMALE FEMALE PIPE PIPE . THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE 1 SHORTER LONGER INLET INLET MALE MALE PIPE PIPE THREAD THREAD MODEL F3-PL, MODEL F3QR-PL OR STANDARD MODEL DH56 HSW-PL MODEL F3, DRY SPRINKLER MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fgO8A Fig. 11 m Fig. 12 - XL02 Wrench Fig. 13 - XL02 Wrench 15- Fig. 14 - XL02 Wrench 0 Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision -made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co., Inc. ® Recycled iablL® (800) 431-1588 Sales Offices Paper s (914) 848-2051 Sales Fax (800) 8-0Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 01/14 P/N 9999970175